Symmons Industries 3DIVBODYNSSRT Temptrol® CCY DIV BDY 4P CPV Operation & Maintenance Manual

Add to My manuals
4 Pages

advertisement

Symmons Industries 3DIVBODYNSSRT Temptrol® CCY DIV BDY 4P CPV Operation & Maintenance Manual | Manualzz

3DIVBODYNSSRT

Triple Outlet Diverter, Non-Sharing

Operation & Maintenance Manual

Model Numbers

 3DIVBODYNSSRT

Triple Outlet Diverter, Non-Sharing

Specification

Triple outlet diverter valve with no shared functionality.

Features male 1/2" IPS and 1/2" sweat inlet/outlet connections (in common plane), defined detents, 3 discreet positions and stringer mounts. Components made from lead free metal construction.

Warranty

Limited Lifetime - to the original end purchaser in consumer/residential installations.

5 Years - for industrial/commercial installations.

Refer to www.symmons.com/warranty for complete warranty information.

Dimensions

Compliance

-ASME A112.18.1/CSA B125.1

FF

A

B

C

D

E

F

G

Measurements

2-5/8", 67 mm

Screwless Escutcheons

Hole Size

Min. Ø 3", 76 mm

Max. Ø 3-1/4", 83 mm

Screw Escutcheons

Hole Size

Min. Ø 1-3/4", 44 mm

Max. Ø 2", 51 mm

5-1/4", 133 mm

(4x) 1/2" male IPS &

(4x) 1/2" sweat

See note 1

4-7/8", 124 mm

Notes:

1) Figure is determined by style of trim attached to shower valve. See rough-in dimension drawing for shower valve application with diverter valve.

2) Dimensions subject to change without notice.

Parts Breakdown

DIVERTER FUNCTION 1

DIVERTER FUNCTION 3

G

C

A

B

D

H

I

B

FROM SHOWER VALVE

DIVERTER FUNCTION 2

E

Item

A

B

Replacement Parts

Description Part Number

Cap Assembly

Spacer

RTS-DIVCAP-

NS-SRT

C Cartridge Extender

RTS-DIVEXT-

NS-SRT

D Cartridge RTS-3DIV-NS

B

G

H

I

Spacer

1" Cap Extender

1" Cartridge Extender

4" Mounting Screws

RTS-DIV-1EXT-

NS

Tools Required

Adjustable

Wrench

Drill (optional)

Plumber Tape

Safety Glasses

Solder

Torch

Important:

Cartridge (D) must be installed with arrow facing down.

2

Installation

Important: Do not plug outlet ports. Do not use diverter as shut-off valve.

Important: Do not expose diverter valve to heat for longer than 2 minutes when sweating in copper tubing.

Doing so may damage the internal components of the valve and will void the product warranty.

3) Position diverter valve (E) so port marked IN is facing down.

E

!

Note: Diverter valve can be installed in wall with shower valve or in an adjoining wall to shower valve.

4) Secure stringer mounts on diverter valve (E) to wood blocking for support.

1) Reference rough-in dimension for shower application with diverter for proper installation of diverter valve.

E

2) Shut-off water supplies.

5) Sweat 1/2" copper tubing from inlet port on diverter valve to water source. Sweat 1/2" copper tubing from outlet ports to desired accessories.

2 3

Optional: Apply plumber tape to male IPS threads on the inlet and outlet ports of diverter valve. Install

1/2"-14 NPT copper fittings to the inlet and outlet ports. Connect outlets to desired accessories.

6) Turn on water supplies to flush plumbing lines free of debris.

Check for leaks.

Note: Securing stringer mounts is necessary for applications where

PEX, or other non rigid tubing, is used to install diverter valve.

Operation

1) Cartridge is factory set to divert to function 1.

POSITION 1

1

2) Turn handle to position 2 to divert to function 2.

POSITION 2

3) Turn handle to position 3 to divert to function 3.

POSITION 3

2 3

3

Maintenance (Cartridge Replacement)

1) Remove cap assembly (A) from diverter valve by turning counterclockwise. Remove cartridge extender (C) and cartridge (D).

2

A

1

C

E

D

2) Inspect cartridge for debris.

Replace cartridge if necessary.

3) Orient new cartridge (D) with arrow facing down. Align pegs on cartridge (D) with indents inside diverter valve (E).

4) Align spindle extender (C) with broach on cartridge (D). Install spindle extender (C) and cap assembly (A) to cartridge (D).

Secure cap assembly (A) by turning clockwise.

2

D

E

1

A

C

D

Note: Spacer (B) will be seated inside cap assembly (A).

Notes:

1) Use caution not to dislodge cartridge from valve body when installing cap assembly (A).

2) Tighten cap assembly (A) to

75 ± 5 lbf-in of torque.

Troubleshooting Chart

Problem

Diverter valve will not divert water.

Water is leaking from the face of the diverter valve.

Cause

Foreign matter in water supply may cause blockages in plumbing lines and the diverter valve cartridge.

Cap assembly is not fully sealed to diverter valve.

Solution

Remove cartridge from diverter valve.

Flush lines free of foreign matter.

Inspect cartridge for debris. Replace cartridge if necessary.

Remove cap assembly. Inspect threads for debris. Reinstall cap assembly to diverter valve at 75 ± 5 lbf-in of torque.

Diverter trim will not install to diverter valve.

Diverter valve body rough-in is too deep.

Use RTS-DIV-1EXT-NS to extend diverter stem 1 inch.

WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.