advertisement
▼
Scroll to page 2
of
8
REMC0218GE Wide Band EMC Benchtop Power Amplifier 2GHz ~18GHz Features • • • • Wideband Power Amplifier Gain: 55dB Output Power +50dBm typical Supply Voltage: 110V/220V AC • • • Wireless Infrastructure Military & Aerospace Test and Measurement Electrical Specifications, TA = +25⁰C Parameter Min. Frequency Range 2 Gain 50 Typ. Max. Units 18 GHz 55 dB Gain Flatness ±5 dB Gain Variation Over Temperature (-40℃~+85℃ ) ±3 dB Input VSWR 2 :1 Output 1dB Compression Point (P1dB) 45 dBm Saturated Output Power ( Psat) (CW) 50 dBm Isolation S12 60 dB Supply Current (110V/ 220V AC) 7 A Efficiency at Psat 10 % Rev 1. 06-10-2020 Weight 360.49 ounces Impedance 50 Ohms Input / Output Connectors Input SMA-Female/Output N-Female Finish White Painted Finish RF-LAMBDA USA Sales: [email protected] Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz Typical Applications www.rflambda.com Technical : [email protected] REMC0218GE Biasing Up Procedure Absolute Maximum Ratings Operating Voltage RF Input Power 230VAC +5dBm Connect input and output with 50 Ohm source/load. ( in band VSWR<1.9:1 or >10dB return loss) Step 2 Turn on AC power Step 3 Enable RF output Power OFF Procedure Step 1 Turn off RF output power Step 2 Turn Off AC power Step 3 Disconnect input and output Environmental Specifications and Test Standards Parameter Description Operational Temperature -40℃~+85℃ (Case Temperature) Storage Temperature -50℃~+105℃ Thermal Shock -40℃ +85℃ (5 Cycles / 10 hours) Random Vibration MIL-STD-202G Table 214-I, Test Condition Letter C 1.5 Hours Per Axis High Temperature Burn In Temperature +85℃ for 72 Hours Shock 1. Weight >20g, 50g half sine wave for 11ms, Speed variation 3.44m/s 2. Weight <=20g, 100g Half sine wave for 6ms, Speed variation 3.75m/s 3. Total 18 times (6 directions, 3 repetitions per direction). Altitude Standard: 30,000 Ft (Epoxy Sealed Controlled Environment) Optional: Hermetically Sealed (60,000 ft. 1.0 PSI min) Hermetically Sealed (Optional) MIL-STD-883 (For Hermetically Sealed Units) Rev 1. 06-10-2020 RF-LAMBDA USA Sales: [email protected] Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz Step 1 www.rflambda.com Technical : [email protected] REMC0218GE Ordering Information Description REMC0218GE 2-18GHz Power Amplifier Amplifier Use Ensure that the amplifier input and output ports are safely terminated into a proper 50 ohm load before turning on the power. Never operate the amplifier without a load. A proper 50 ohm load is defined as a load with impedance less than 1.9:1 or return loss larger than 10dB relative to 50 Ohm within the specified operating band width. Power Supply Requirements Power supply must be able to provide adequate current for the amplifier. Power supply should be able to provide 1.5 times the typical current or 1.2 times the maximum current (whichever is greater). In most cases, RF - Lambda amplifiers will withstand severe mismatches without damage. However, operation with poor loads is discouraged. If prolonged operation with poor or unknown loads is expected, an external device such as an isolator or circulator should be used to protect the amplifier. Ensure that the power is off when connecting or disconnecting the input or output of the amp. Prevent overdriving the amplifier. Do not exceed the recommended input power level. Adequate heat-sinking required for RF amplifier modules. Please inquire. Amplifiers do not contain Thermal protection, Reverse DC polarity or Over voltage protection with the exception of a few models. Please inquire. Proper electrostatic discharge (ESD) precautions are recommended to avoid performance degradation or loss of functionality. Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz Part No. What is not covered with warranty? Each RF - Lambda amplifier will go through power and temperature stress testing. Since the die, ICs or MMICs are fragile, these are not covered by warranty. Any damage to these will NOT be free to repair. Rev 1. 06-10-2020 RF-LAMBDA USA Sales: [email protected] www.rflambda.com Technical : [email protected] REMC0218GE EMC Equipment User Manual Front Panel ON/OFF switch Alarm Indicator Keypad Gain Adjustment Knob RF Output RF Input Rear Panel Instrument AC power supply switch Fuse Holder Main AC connector GND connector USER CONTROL, D-SUB Connector low-voltage (3.3V) TTL control signals. See page below for more information. Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz Power Indicator USB Port (upon request) LAN Port (upon request) Rev 1. 06-10-2020 RF-LAMBDA USA Sales: [email protected] www.rflambda.com Technical : [email protected] REMC0218GE Front Panel LCD Screen Display Switching On Instrument Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz Please follow the instructions on the front panel LCD screen after switching on the power. Press “1” on keypad to continue. Self Calibration Screen Calibration is may be recommended “[1] Calibrate” to execute instrument self calibration process. “[2] Reset” to reboot the instrument. *Please turn OFF RF input power, and terminate the RF output port while applying calibration function Instrument Protection Alarms The front panel LCD screen will display the error code or error message when instrument self protection is triggered. Front panel alarm indicator will light up. To eliminate the error code, press “RESET” on front panel keypad to reboot the instrument and clear the alarms. If error code can not be eliminated after reboot, please contact [email protected] Rev 1. 06-10-2020 RF-LAMBDA USA Sales: [email protected] www.rflambda.com Technical : [email protected] REMC0218GE Instrument Status Display Page Indicates instrument RF output status. It will display: Output is Ready to Turn on or RF Output is ON Press “Menu” on keypad to enter instrument functions selection menu User can set a constant gain for the unit. Equipment will automatically adjust the gain at certain frequency Switches On or Off for instrument RF output port Instrument Function Selection Page To enter this function selection page, press “Menu” on front panel keypad while the instrument is showing the status page. Press the corresponding number on front panel keypad to select: “[1] Calibrate” calibrates the instruments. “[2] Frequency” enters RF input signal center frequency. “[3] RF ON/OFF” switches the RF output port on or off. “[4] Reset” Restarts the instrument (Turns RF output off) “[5] Status” enters instrument status display page. “[6] Product Info” displays product part number and serial number Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz Instrument temperature RF output attenuation (change with adjustment knob) RF input signal center frequency Instrument RF output power All action functions will ask for confirming execution when selected from function selection menu. Rev 1. 06-10-2020 RF-LAMBDA USA Sales: [email protected] www.rflambda.com Technical : [email protected] REMC0218GE User Control Connector on Rear Panel Name Function 1 Reset Control 2 Driver Disable Control 3 Drain Disable 4 Initial State Description Applied Resets PA when logic LOW is applied and released Yes LOW Appling logic HIGH disables driver of amplifiers Yes Control LOW Applying logic HIGH disables drain of amplifiers Yes RF IN Over Indicator LOW Pin will be latched to logic HIGH when input signal is over limit No 5 Temp Over Indicator LOW Pin will be latched to logic HIGH when amplifier is driven over temperature Yes 6 Current Over Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when an imbalance in the drain current of the combining branches occurs Yes 8 PA input power Indicator PA input power is represented by voltage No 9 PA output power Indicator PA output power is represented by voltage No 10 PA output reflection power Indicator PA output reflection power is represented by voltage No 11 VSWR Indicator LOW Pin will be latched to logic HIGH when output reflection is over limit No 13 +5V Power Supply +5V +5V DC is supplied for reference Yes 14 GND Ground GND Ground Yes 15 GND Ground GND Ground Yes Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz Pin # HIGH/LOW voltages are standard TTL signals: 0.0V-0.8V = LOW 2V-5V = HIGH Rev 1. 06-10-2020 RF-LAMBDA USA Sales: [email protected] www.rflambda.com Technical : [email protected] REMC0218GE Amplifier Outline Drawing: All Dimensions in mm [inches] 482.6 [19.000] 465 [18.307] 11 [0.433] 7 [0.276] 133.2 [5.244] PN:REMC18G40GM Freq:18-40GHz Wide Band EMC Benchtop Power Amplifier 2GHz ~ 18GHz 46.11 [1.815] 25.75 [1.014] 506.94 [19.958] 447 [17.598] 436.8 [17.197] Important Notice The information contained herein is believed to be reliable. RF-Lambda makes no warranties regarding the information contained herein. RF-Lambda assumes no responsibility or liability whatsoever for any of the information contained herein. RF-Lambda assumes no responsibility or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for RF-Lambda products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by such information. RF-Lambda products are not warranted or authorized for use as critical components in medical, life-saving, or life sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal injury or death. Rev 1. 06-10-2020 RF-LAMBDA USA Sales: [email protected] www.rflambda.com Technical : [email protected]
advertisement
Related manuals
advertisement