San Jose Technology Unictron SANAV SJ-205HAB User Manual


Add to my manuals
51 Pages

advertisement

San Jose Technology Unictron SANAV SJ-205HAB User Manual | Manualzz
SANAV SJ-205HAB
Home Unit
User Manual
Part Number: SJ-205HAB
Doc Type : User Manual
Doc Id: WI-RD-E-047
Reversion : V1.0
Copyright © 2020 San Jose Technology, Inc. All Rights Reserved.
This document contains information that is the property of SANAV. This document may
not be copied, reproduced, reduced to any electronic medium or machine readable form,
or otherwise duplicated, and the information herein may not be used, disseminated or
otherwise disclosed, except with the prior written consent of SANAV
1
Document Amendments............................................................................................... 5
SJ-205HAB Hardware General Introduction......................................................... 6
Specification...................................................................................................................... 6
Package Contents............................................................................................................7
Front View.......................................................................................................................... 8
SJ-205HAB Quick START/Setting Guide.............................................................. 10
Command Setup for SJ-205HAB.............................................................................11
Change User Name...................................................................................................... 12
Change Password..........................................................................................................13
Request IMEI Number................................................................................................ 14
Set up APN for mobile network Service............................................................... 15
Set up URL.......................................................................................................................17
Set up TCP ACK function............................................................................................19
Set up Phone Book List.............................................................................................. 20
Set up Location Auto Report Mode ........................................................................ 21
Set up Answer Call Mode........................................................................................... 22
Set up Mandatory Polling report............................................................................. 23
Set up Route for Data Transmission...................................................................... 24
Get Pairing Information.............................................................................................. 25
Set up Auto Reboot Time.......................................................................................... 26
Set up TCP/UDP Server Address............................................................................ 27
Set up Turbo Link Mode............................................................................................. 28
Set up Command By GPRS....................................................................................... 29
Set up Device Position................................................................................................ 30
Set up RTC time............................................................................................................ 31
Set up Tamper Function............................................................................................. 32
Set up Vibration Detection Function..................................................................... 33
Set up Alarm OFF ......................................................................................................... 34
Disable the beep sound when alarm event is triggered................................ 35
Set up RF power of Home unit................................................................................ 36
Set up AES 128 Encryption....................................................................................... 37
Set up FOTA (Over-the-Air Technology).............................................................. 38
Set up paired with the bracelet (NB5)................................................................. 39
Set up unpaired with the bracelet (NB5)............................................................ 40
IDRST (Clear all of the idpair at the same time)............................................. 41
RF Command.................................................................................................................. 42
Erase the Backup Data(Clear the flash memory)............................................ 43
Setup buzzing when receiving RF signal............................................................. 44
Setup RFall feature ...................................................................................................... 45
Set up Low Power reminder..................................................................................... 46
Appendix 1: Tracker Event List ............................................................................... 47
2
© Unictron Technologies Corp.
All specifications subject to change without notice.
Contents
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
3
© Unictron Technologies Corp.
All specifications subject to change without notice.
Appendix 2: Report Data Output Format............................................................ 48
Appendix 3: NB5 & RF Within SJ-205HAB Range(RF Tag event)............... 49
Warranty Regulation.................................................................................................... 50
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
Introduction
SANAV SJ-205HAB is a low-powered, more compact version of 2G/3G tracker
targeting the animal or asset tracking market. Moving targets can be tracked in
real-time through internet or specified terminals. The device can communicate with
the server through 2G/3G networks, to provide emergency & power alerts, geofencing, remote monitoring, and automatic back-up regarding tracking history.
This User Manual details the product specifications, hardware features, SMS
commands, and Tracker Status of SJ-205HAB. If you have any further questions about
using SANAV’s SJ-205HAB product, please contact SANAV Customer Service at
www.sanav.com.
Disclaimer
© Unictron Technologies Corp.
All specifications subject to change without notice.
SJ-205HAB User Documentation
This document, and all other related products, such as device, firmware, and software,
is developed by SANAV. At the time of release, the product is known to be most
compatible with the specified firmware version. SANAV continuously seeks to research,
develop and improve the functionalities of the devices, which may subject the device
to change in protocol, specification, and firmware functions without prior notice.
SANAV is obligated to modify all documentation without limitation of time frame. A
change notice shall be released to SANAV customers upon the completion of document
modification.
SANAV products are not intended to be used as life support or rescue equipment.
SANAV is not liable for any loss or injury caused by using or referencing any products.
Any possible means of using or integrating SANAV products shall be avoided.
4
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
Revision
1.0
5
Date
2020/10/26
Comments
Formal release
© Unictron Technologies Corp.
All specifications subject to change without notice.
Document Amendments
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
Specification
Specifications
Electrics Data
RF Frequency:
436.8MHz
Antenna
Embedded GSM and RF Antenna
GSM Frequency
GSM/GPRS/EDGE: Quad band 850/900/1800/1900MHz
UMTS/HSPA+: Five band 800/850/900/1900/2100MHz
GSM Module
Cinterion EHS6
Memory
Built-in 32M X 8bit NAND FLASH
© Unictron Technologies Corp.
All specifications subject to change without notice.
SJ-205HAB Hardware General Introduction
Power Supply
External Power Supply
12V DC / 18W
Internal Battery Life
4 hours (based on 1 report/1 minutes, No alarm)
Environmental Conditions
Charging Temperature
0°C ~40°C
Operating
-10°C to +45°C
Temperature
Relative Humidity
5% to 95 %, non-condensing
Mechanics Data
6
Size
181mm (L) * 138mm (W) * 50mm (H)
Weight
600g (2600mAhLi-ION battery included)
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
SJ-205HAB x 1
Adapter
© Unictron Technologies Corp.
All specifications subject to change without notice.
Package Contents
AC Adapter x 1 100~240V AC / 1.2A
Note: Connect Power Cord to AC Adapter to be a whole power charging solution.
7
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Front View
Green LED (Label 1): Power ON – both external and internal

Light on when it is powered on
Red LED (Label 2): SIGNAL Status

Turn on when GSM is in service

Flash per 1s when without GSM service
Red LED (Label 3): Home Unit Tamper Alert

Light on when Home Unit is tampered
Orange LED (Label 4): Status of Home Unit

Flash once when transmitting a data via GPRS or SMS
Green LED (Label 5): External Power Detection Indicator
Turn on when external power has been plugged
8
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
Power Supply Connect
12V DC Input
9
© Unictron Technologies Corp.
All specifications subject to change without notice.
Charging SJ-205HAB
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
www.unictron.com
www.sanav.com
STEP 1: APN Identification. Ensure APN Name, APN username and APN password for GSM SIM Card
Cell carrier. Wrong APN setting will cause the device unable to report via internet service.
STEP 2: Send SMS command to device (Check the IMEI and make sure device can be set up by
SMS): #username,0000,imei*
STEP 3: Send SMS command to device to set up APN:
#username,0000,3,APN,username,password,DNS (if needed)*
default: #username,0000,3,internet,,*(if empty, leave commas right after)
© Unictron Technologies Corp.
All specifications subject to change without notice.
SJ-205HAB Quick START/Setting Guide
STEP 4: Send SMS command to point to TCP server: #username,0000,18,192.168.1.100:18888*
(Send SMS Message to point to http server: #username,0000,4,http://www.xyz.com/Data*)
STEP 5: Send SMS command to device to report via TCP: #username,0000,14,7*
(Send SMS Message to device to report via http: #username,0000,14,2*)
SETP 6: Set RTC Time:#username,0000,setrtc,161012141000*
SETP 7: Pair with bracelets
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
10
www.unictron.com
www.sanav.com
SJ-205HAB currently provides SMS command and COTA (TCP) command for remote setup. User can setup the
SJ-205HAB by following the instructions shown in following chapters via SMS/COTA. Key the specific SMS
message in your cellular phone and send it to the SIM number of SJ-205HAB. The setup messages are showed
in the following sections.
1: The default setting:
Default ID is “USERNAME”. Please read chapter Change User Name to desired ID.
Default password is “0000”. Please read chapter Change Password to change the password.
There is no number in the default contact. Please read chapter Set up Phone Book List to add the number.
Default setting of Retrospective Location Mode is deactivated. Please read chapter Set up Retrospective
© Unictron Technologies Corp.
All specifications subject to change without notice.
Command Setup for SJ-205HAB
Location Mode by Time to setup the regular Retrospective Location Mode.
Default setting of APN is only suitable for mobile network. Please read chapter Set up APN for MOBILE
NETWORK Service to change the APN.
Default setting of URL is http://www.sanavtw.com/uploadM1.php. Please read chapter Set up URL to
change the URL for http server setup.
Before doing any setup, please ensure the device is connected with the GSM network. The GSM LED must light
on. And please note the device is not in SOS/Panic mode.
2: Please note that all the characters which include #, * and comma (,) should be HALFWIDTH form.
3: Please be aware of the upper (capital)/lower cases when entering the SMS command.
4: While entering any SMS command, note that NO SPACE is allowed between the characters, comma and
signs in the SMS.
5: Any setup command must be started with a “#” sign and ended up with a “*” sign.
6: The comma (,) can be abbreviated if no further setup required for the command besides Set up APN for LTE
Service. Please refer to the examples of Set up Retrospective Location Mode.
7: Add or not add the “+ “sign in front of the cellular phone number(s) are both acceptable, while the”+” sign
should precede the international call prefixes. The specified international call prefix is required if “+ “sign is not
added.
8: The device will update setting Only when the password, USERNAME and setup command are all correct.
If the command is not valid, a failure report is going to be sent to the user’s cell phone.
9: Some PREPAID PHONE CARD SIM modules do not enable or even support MOBILE NETWORK service. Please
consult with GSM carrier for further information.
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
11
www.unictron.com
www.sanav.com
Generally, SMS command execution needs correct user name with password, or it will remain the same setting.
The SMS command default user name is “username”. It can be changed by following the command format.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Change User Name
For example, entering the SMS command as the following allows user to change the user name from “username”
to a new user name “SANAV”.
Only enter new command with new user name after it has been changed.
Setup Format: #「username」,「Password」,「Function Mode」,「New User Name」*
Command: #username,0000,1,SANAV *
SMS/ COTA Command
Description
#
Start sign.
username
Default
0000

Default password.

If you have changed the password, please use the updated one.
username of the device.
1
Mode 1 defines user name setup mode.
SANAV

New user name changed by the user.

At the maximum of 16 characters, including a~z,A~Z,0~9, @ - _ / .!%&

Please note whether the letters are capitalized or lowercased when
sending the command.
*
End sign.
Table 1: User Name Change Format Description
Situation
Message Reply
Setup Succeeds
[username] + Device username is updated.
Setup Fails
[username] + Device username setup fail!
Incorrect username or
password,
[username] + command error
Incorrect command format
Table 2: User Name Change Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
12
www.unictron.com
www.sanav.com
Generally, SMS command execution needs correct user name with password, or it will remain the same setting.
The SMS command default password is “0000”. It can be changed by following the command format.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Change Password
For example, entering the SMS command as the following allows user to change the password from “0000” to
a new password “1111”.
Only enter new command with new password after it has been changed.
Setup Format: #「username」,「Password」,「Function Mode」,「new Password」,「new Password」*
Command: #USERNAME,0000,2,1111,1111*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the USERNAME, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
2
Mode 2 defines the password setup mode.
1111
New password (Please note at the maximum of 4 number)
1111
Reconfirm the password
*
End sign.
Table 3: Password Change Format Description
Situation
Message Reply
Setup Succeeds
[username] + Device Password is updated.
Setup Fail
[username] + Password setup Fail!
Incorrect password
[username] + Password setup Fail!
Incorrect username or SMS
format
[username] + command error
Table 4: Password Change Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
13
www.unictron.com
www.sanav.com
IMEI stands for International Mobile Equipment Identification, a unique number for identifying mobile devices
validity in 2G/3G network.
As above stated, each device has a unique IMEI number. Entering the command as the following allows user to
check the IMEI number of the device for network registration and tracking.
Setup Format: #「USERNAME」,「Password」,「Function Mode」*
Command: #USERNAME,0000,imei*
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Request IMEI Number
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
imei
Mode “imei” defines the device IMEI number request mode.
*
End sign.
Table 5: IMEI Number Request Format Description
Situation
Message Reply
Setup Succeeds
[username] + ‘,[imei]’
Incorrect username or
[username] + command error
password,
Incorrect command format
Table 6: IMEI Number Request Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
14
www.unictron.com
www.sanav.com
Access Point Name (APN) is a protocol that typically allows a user's device to access the internet using the
mobile phone network. It is a network identifier used by a mobile device when connecting to a 2G/3G carrier.
The carrier will then examine this identifier to determine what type of network connection should be created.
For uploading the data to a web server, a set of 2G/3G APN from your 2G/3G network is required. Various
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up APN for mobile network Service
2G/3G networks provide different 2G/3G APN settings. Please ask your 2G/3G carrier about the APN settings.
If the user name and password of APN are indefinite or showed in blank, just leave the parameters empty (no
space). User can follow the Setup Format below to setup the APN that is provided by your 2G/3G carrier.
Setup Format: #「USERNAME」,「Password」,「Function Mode」,「APN」,「APN name」,「APN password」,
「APN DNS」*
Example1: #USERNAME,0000,3,internet,guest,guest,172.20.2.10*
Leave the parameters empty (no space) if other parameters are not required.
Example2: #USERNAME,0000,3,internet,,,*
Note1: The total length of APN name, APN USERNAME, APN Password, and APN DNS should be less than 70
characters.
Note2: Some PREPAID PHONE CARD SIM modules do not enable or even support 2G/3G service. Please consult
with 2G/3G carrier for further information.
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
Function Mode
Mode 3 defines the APN setup mode.
internet
APN Name
guest
APN user name (optional)
guest
APN Password (optional)
172.20.2.10
APN DNS (optional)
*
End sign.
Table 7: APN Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
15
www.unictron.com
www.sanav.com
Message Reply
Setup Succeeds
[username] + Device GPRS APN is updated.
Setup Fail
[username] + Device GPRS APN setup Fail!
Incorrect username or
[username] + command error
password,
Incorrect
command
format
Table 8: APN Setup Response Description
© Unictron Technologies Corp.
All specifications subject to change without notice.
Situation
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
16
www.unictron.com
www.sanav.com
This SMS command instructs the device to transmit GPS (GPRMC) positioning data to a specified URL (Uniform
Resource Locator) or IP address of HTTP protocol server for real time GPS tracking.
Entering the SMS command as the following allows user to changes the address to
“http://www.sanavtw.com/uploadM1.php”. The address will be assigned to receive the GPS data sent by
the device. Then you can link to Sanav Test Website: https://www.sanavtw.com to view your device
data.
Setup Format: #「USERNAME」,「Password」,「Function Mode」,「URL」*
Command: #USERNAME,0000,4,http://www.sanavtw.com/uploadM1.php*
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up URL
Note: The URL should be less than 80 characters.
Note1: The question mark ‘?’ or any symbol is not allowed to be entered behind the URL. The DEVICE will add
the necessary symbol(s) on automatically.
Note2: For setting up TCP/IP (Transmission Control Protocol) or UDP/IP (User Datagram Protocol) server, please
refer to Set up TCP or UDP/IP.
Note3: HTTP, TCP/IP, UDP/IP and SMS are different protocols (routes). Please refer to Set up Route for Data
Transmission to set up corresponded route code for GPS data transmission.
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
Function Mode
Mode 4 defines the URL setup mode.
Address
URL of the HTTP server.
*
End sign.
Table 9: URL or IP Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
17
www.unictron.com
www.sanav.com
Message Reply
Setup Succeeds
[username] + Device IP/Domain is updated.
Setup Fail
[username] + IP/Domain setup Fail!
Incorrect username or
[username] + command error
password
Incorrect command format
Table 10: URL or IP Setup Response Description
© Unictron Technologies Corp.
All specifications subject to change without notice.
Situation
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
18
www.unictron.com
www.sanav.com
The Home Unit has TCP ACK function to make sure no data lose. Use this command to toggle this feature.
Setup format: #<User Name>, <Password>, <Function Code>, <ON/OFF>, <Timeout>*
Command: #username,0000,tcpack,1,10*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
tcpack
Function code.
1
1: ON, 0: OFF
10
Timeout (sec) The range is 1~255.
*
End sign.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up TCP ACK function
Table 11: TCP Ack Setup Format Description
Situation
Response
Setup Succeeds
[username] + setup OK. Device tcp ack mode is updated.
Incorrect username or
[username] + command error
password,
Incorrect command
format
Table 12: TCP Ack Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
19
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Phone Book List
There are three main purposes of Phone Book List setup:
The Home Unit can save 10 phone numbers for receiving or sanding SMS.
Function Code “5” can setup phone1~3
Function Code “e5” can setup phone4~10
Use this SMS command to set up the cellular phone book as the following format:
Setup Format: #<User Name>, <Password>, <Function Code>, <Phone number>*
Command: #username,0000,5, phone1,phone2,phone3*
#username,0000,e5,phone4,phone5,phone6,phone7,phone8,phone9,phone10*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
5 or e5
Mode ‘5’ or ‘e5’ defines phone number setup mode.
Phone Number
Add phone number
*
End sign.
Table 13: Phone Book List Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] + Device phone book is updated.
Setup Fail
[username] + Phone book setup Fail!
Incorrect username or
[username] + command error
password,
Incorrect command format
Table 14: Phone Number List Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
20
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Location Auto Report Mode
Generally, the device will generate GPS (GPRMC) data and report to server, specified cellular phone or network
routes. Retrospective Location Mode setup can enable the device report GPS data automatically during a period
of time.
Use this command to set up the frequency of Retrospective Location Mode. The device can report according to
time interval. If you send the SMS command as the following example, the device will send a report every 5
minutes (300 seconds) and the total number of reports is 99.
Note: You may limit the number of the Auto Reports by inputting the digits from 1 to 9998 in the<total number
of reports>field. When you input 9999, the device will generate unlimited Location Auto Reports. when 0 is
entered, the device will stop/disable Location Auto Report Mode.
Setup Format: #「USERNAME」,「Password」,「Function Code」,「intervals (sec)」,「total number of report」
*
Example1:#USERNAME,0000,6,300,99*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default user name of the device.

If you have changed the USERNAME, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
6
Mode 6 defines Retrospective Location Mode setup mode.
300
Time Interval (period) of Retrospective Location Mode.
99
Times (frequency) of Auto Reports that will be sent automatically.
*
End sign.
Table 15: Location Auto report Mode Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] + Setup OK. Device Auto Report setting is updated.
Setup Fail
[username] + Auto Report setting Setup Fail!
Incorrect username,
Incorrect password or
[username] + command error
command format
Table 16: Location Auto report Mode Setup Response Descriptio
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
21
www.unictron.com
www.sanav.com
User can use Answer Call (Voice Mode) command to define the response when MU-201 S3 is receiving an
incoming call.
The device can answer the call automatically or hang up the call and send current location message.
Setup Format: #「USERNAME」,「Password」,「Function Mode」, 「Mode」*
Command: #USERNAME,0000,8,1*
Note: If user has enabled “Security Phone Book” function, MU-201 S3 will verify whether the caller’s number is
in the Security Phone Book. If not, MU-201 S3 will not react to the incoming call.
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Answer Call Mode
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
8
Mode
Mode 8 defines the Voice Mode setup.
0 The device will answer the incoming call automatically.
1 The device will answer the incoming call automatically.
2
3
4
*
The device will hang up the call and respond its current location to caller’s cell
phone.
The device will hang up the call and respond its current location to the defined
route.
Hang up phone and reply a SMS for mobile Application
End sign.
Table 17: Answer Call Mode Setup Format Description
Situation
Message Reply
Setup Succeeds
<OK>USERNAME, setup OK, 8
Table 18: Answer Call Mode Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
22
www.unictron.com
www.sanav.com
The user can send the SMS/COTA polling according to the shown example to get desired information. It defines
the report format when you set SMS polling.
Setup Format: #「USERNAME」,「Password」,「Function Mode」*
Command: #USERNAME,0000,10*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
10
Mode 10 defines the SMS Polling setup mode.
*
End sign.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Mandatory Polling report
Table 19: Polling Format Setup Description
Situation
Message Reply
Example Report :
Setup Succeeds
HAB,352557100308249,$GPRMC,132417.000,A,2458.9733,N,12125.6597,E,0.00,0.00,080
720,,,A*48,POLL,,,,,N0004,M15,4108mV
Table 20: Polling Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
23
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Route for Data Transmission
User can follow the instructions below to set the device’s data transmission via HTTP/TCP/UDP or SMS routes.
Please confirm the back-end server protocol type and corresponding URL or IP address (with port number if
required) before setup. There are 2 main protocols available for transmitting route setup:
1. HTTP: Hypertext Transfer Protocol. An internet browser based server protocol that usually has a specified URL
(Uniform Resource Locator).
2. TCP/IP: Transmission Control Protocol. An OSI Transport layer protocol that has more complex frame
structure, higher reliability but slower processing speed than UDP/IP.
User can choose the route to transmit the data by HTTP/TCP protocol individually.
Please refer to the following table for the route setup.
Setup Format: #「USERNAME」,「Password」,「Function Mode」,「2 or 7」*
Command: #USERNAME,0000,14,2*(HTTP Only)
#USERNAME,0000,14,7*(TCP Only)
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
14
Mode 14 defines Transmission Route mode.
2 HTTP only. Send data to HTTP server. No SMS backup route.
7 TCP Only. Send data to TCP server. No SMS backup route.
*
End sign.
Table21: Transmission Route Setup Format Description
Situation
Setup Succeeds
Message Reply
[username] + Device is switching to HTTP mode
[username] + Device is switching to TCP mode
Table22: Transmission Route Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
24
www.unictron.com
www.sanav.com
Use this SMS/COTA command to get pairing device ID and status.
Setup Format: #「USERNAME」,「Password」,「Function Mode」*
Command: #USERNAME,0000,apstatus*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
apstatus
“apstatus” defines the get pairing information mode
*
End sign.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Get Pairing Information
Table23: Get Pairing Information Setup Format Description
Situation
Message Reply
<AP number>,<Device ID>,<N(Reserve)>
Example:
AP01:I001,N; AP02:I010,N; AP03:00,N; AP04:00,N; AP05:00,N; AP06:00,N;
Setup Succeeds
AP07:00,N; AP08:00,N; AP09:00,N; AP10:00,N; AP11:00,N; AP12:00,N;
AP13:00,N; AP14:00,N; AP15:00,N; AP16:00,N; AP17:00,N; AP18:00,N;
AP19:00,N; AP20:00,N
Table24: Get Pairing Information Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
25
www.unictron.com
www.sanav.com
User can use the following commands below to set the device’s auto reboot for clean up the system status
regularly.
Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Intervals (30 min.) 」*
Command: #USERNAME,0000,rst,48 *
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Auto Reboot Time
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
rst
“rst” defines the auto reboot mode
48
30 minutes as a unit. The range is 0 to 99. 0 is disable.
Example: 48 means 24hr reboot once
*
End sign.
Table25: Auto Reboot Time Setup Format Description
Situation
Message Reply
[username] + Auto Reset is defined.
Setup Succeeds
[username] + Auto Reset is disabled.
Incorrect username or
password,
[username] + command error
Incorrect command format
Table26: Auto Reboot Time Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
26
www.unictron.com
www.sanav.com
User can use the following commands below to set the device’s GPS (GPRMC) positioning data to a specified IP
address and port for real time tracking.
Entering the SMS command as the following allows user to change the address to specified IP and port. The IP
address will be assigned to receive the GPS data sent by the device.
Setup Format: #「USERNAME」,「Password」,「Function Mode」, 「TCP/UDP server address」*
Command: #USERNAME,0000,18,220.128.123.1:7878 *
Or #USERNAME,0000,18,icare-u.com.tw:12345*
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up TCP/UDP Server Address
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
18
Mode 18 defines the TCP/UDP Server Address setup mode.
220.128.123.1:7878
TCP/UDP Server Address and Port / Domain name
*
End sign.
Table27: Server Address Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] + Device TCP/UDP is updated
Incorrect username or
[username] + command error
password,
Incorrect command format
Table28: Server Address Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
27
www.unictron.com
www.sanav.com
User can use the following commands below to set the device to maintain network connection or disconnect
after reporting data.
Setup format:#「USERNAME」,「Password」,「Function mode」, 「ON/OFF」*
Command: #USERNAME,0000,trb,0*
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Turbo Link Mode
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
trb
turbo mode.
0 Network disconnection when the report finishes.
1 Network keep connection when the report finishes.
*
End sign.
Table29: Turbo Mode Setup Format Description
Situation
Setup Succeeds
Message Reply
[username] + setup OK. Device turbo mode is turned on.
[username] + setup OK. Device turbo mode is turned off.
Setup Fail
[username] + turbo mode setup fail.
Incorrect username or
password,
[username] + command error
Incorrect command format
Table30: Turbo Mode Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
28
www.unictron.com
www.sanav.com
Use this SMS command to setup sending commands over the network.
Setup Format: #「USERNAME」,「Password」,「Function Mode」,「0/1」,「IP: Port」*
Command: #USERNAME,0000,cmdbygprs,0,202.39.31.179:13377*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
cmdbygprs
Function code
0
After the command
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Command By GPRS
0: disconnect after 1 minute of inactivity
1: keep connect
202.39.31.179:13377
IP address; Domain name also is acceptable.
*
End sign.
Table31: Command By GPRS Setup Format Description
Situation
Message Reply
[username] + Device cmdbygprs is Disabled.
Setup Succeeds
[username] + Device cmdbygprs is Enabled.
Setup Fail
[username] + cmdbygprs setup Fail!
Incorrect username or
password,
[username] + command error
Incorrect command format
Table32: Command By GPRS Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
29
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Device Position
User can use the following commands below to set the device positon.
Setup Format:
#「USERNAME」,「Password」,「Function Mode」,「Latitude」,「N/S」,「Longitude」,「E/W」*
Command: #username,0000,gpspos,2458.0000,N,12136.0000,E*
SMS/ COTA Command
Description
#
Start sign.
USERNAME

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
gpspos
Function code
2458.0000
Latitude
N
North / South
12136.0000
Longitude
E
East / West
*
End sign.
Table33: device positon Setup Description
Situation
Message Reply
Setup Succeeds
[username] + setup OK. Device region coordinates setting is updated.
Setup Fail
[username] + GPS Position setup Fail!
Incorrect username or
password,
[username] + command error
Incorrect command format
Table34: device positon Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
30
www.unictron.com
www.sanav.com
User can use the following commands below to set the RTC time.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「YYYY&MM&DD&TTTTTT」*
Command: #username,0000,setrtc,150115115000*
COTA Setup format:<@PCswrtc>,<YYYY&MM&DD&TTTTTT>
COTA Command: @PCswsetrtc,170528170501
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up RTC time
SMS/ COTA Command Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
setrtc
“setrtc” defines the RTC time setup mode
15 Christian era (2015)
01 month (May)
150115115000
15 date (28th)
1150 time (17:05)
00 Second(00)
*
End sign.
Table35: RTC time Setup Format Description
Situation
Response
Success
[username] + setup OK. Device RTC settings is updated.
Setup Fail
[username] + GPS Position setup Fail!
Incorrect username or
password,
Incorrect command
[username] + command error
format
Table36: RTC time Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
31
www.unictron.com
www.sanav.com
The Home Unit tamper switch is located at rear side of Home Unit and should be pressed for detection.
Once the Home Unit is moved to have tamper status changed, the Home Unit will report periodical tamper event
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Tamper Function
with loud beep sound. The way to stop event reporting and beep sound is sending SMS command of “ALARMOFF”
or hardware reset.
As Tamper event is triggered, the device will send TT reports to the server according to the related setting.
There are two types of command, the short one is for toggling the function quickly and the long one is for setting
up all the parameter
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「ON/OFF」,「Report Interval」,「Detection
delay time」*
SMS Command: #username,0000,tamper,1*
#username,0000,tamper,1,60,3*
COTA Setup format:<@PCswtamper>,<ON/OFF>,<Report Interval>,<Detection delay time>
COTA Command: @PCswfbr,1,60,3
SMS/ COTA Command Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
tamper
“tamper” defines the Tamper report setup mode
1
60
3
ON/OFF switch. (1: ON, 0: OFF)
TT Report interval (60 sec.). The range is 15 to 65000.
Detection delay time (Unit : Second)
Once tamper status have been changed, it will have the delay time to trigger the TT
event to avoid the false alarm.
Generally this value has no need to be changed.
*
End sign.
Table37: Tamper Function Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
32
www.unictron.com
www.sanav.com
The Home Unit has built-in vibration detection function.
Once the Home Unit is moved and detected by vibration sensor, the Home Unit will report periodical vibration
event with loud beep sound. This MT event which generates MT reports will end when the home unit stops
moving.
There are two types of command, the short one is for toggling the function quickly and the long one is for setting
up all the parameter
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Vibration Detection Function
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「ON/OFF」,「Report Interval」,「Report
times」,「Sensitivity」*
SMS Command: #username,0000,vs,1*
#username,0000,vs,1,60,2,4*
COTA Setup format:<@PCswvs>, <ON/OFF>, <Report Interval>, <Report Times>, <Sensitivity>
COTA Command: @PCswvs,1,60,2,4
SMS/ COTA Command Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
vs
“vs” defines the MT report setup mode
1
ON/OFF switch. (1: ON, 0: OFF)
60
MT Report interval (60 sec.). The range is 15 to 65000.
2
Total report times (2 times)
4
Sensitivity ranges from 1 (most sensitive) to 10(least sensitive). The default value is
4
*
End sign.
Table38: Tamper Function Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
33
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Alarm OFF
The Home Unit has alarm off function to disable all current alarm reporting and return to normal status as the
following:
Rear Side Tamper Switch (TT)
Once the alarm off command is sent, the Home Unit will stop all current alarm reporting (alarm status).
Note that the device still is detecting violation event.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」*
SMS Command: #username,0000,alarmoff *
COTA Setup format:<@PCswalarmoff>
COTA Command: @PCswalarmoff
SMS/ COTA Command Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
alarmoff
“alarmoff” defines the alarm OFF mode
*
End sign.
Table39: Alarm off Function Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
34
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Disable the beep sound when alarm event is triggered
When the alarm events such as MT event are triggered, SJ-205HAB (Home Unit) will generate the beep sound
during the event until it has received the “Alarmoff” Command. We can disable this beep sound.
The device still alarms as the event has been triggered but without beep sound While this feature is disabled.
Use this command to toggle this feature.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,<ON/OFF>,<BEEP Interval>*
SMS Command: #username,0000,19,1,3*
#username,0000,19,0*
SMS/ COTA Command Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
19
Function code 19 which toggle this beep sound when alarm event occurs.
1
ON/OFF switch. (1: ON, 0: OFF)
3
The interval of the beep sound. Unit: second.
*
End sign.
Table40: Alarm off Function Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
35
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up RF power of Home unit
The ankle bracelet RF transmit power can be set for HAB (Home Unit) curfew range adjustment as well as the
Home Unit RF transmit power.
RF transmit power:
There are totally 8 levels of RF transmit power that can be set. The stronger the RF transmit power is, the wider
the curfew range would be. We always adjust the level of RF transmit power for both the bracelet.
We recommend keeping the level of RF transmit power of Home Unit as default value (8).
RF channel:
RF channel defines that all types of equipment (HA (bracelet), HAB (Home Unit), XT (Transmitter)) should use
the same channel to communicate with each other. In some cases there are a number of sets of equipment in
the same place (such as more than 10 sets), we can set them in groups and configure each set to a different
channel, and it will reduce the possibility of disturbing each other. Generally, we don’t have to change the
default channel.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,< RF Power Level >,< RF Channel >*
SMS Command: #username,0000,rfpw,8,10*
SMS/ COTA Command Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
rfpw
Mode “rfpw” defines RF power level setup mode.
8
RF power level. Ranges from 1(min) to 8(max). (The default is 8)
10
RF channel. Ranges from 1 to 150. (The default is 10)
*
End sign.
Table41: RF Power Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
36
www.unictron.com
www.sanav.com
The Home Unit has data encryption function to protect the transmitted data. Use this command to toggle this
feature.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,<ON/OFF>*
SMS Command: #username,0000,aes,1*
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up AES 128 Encryption
SMS/ COTA Command Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
aes
“aes” defines the AES 128 encryption setup mode
1
ON/OFF switch. (1: ON, 0: OFF)
*
End sign.
Table42: AES 128 Encryption Setup Format Description
Situation
Setup Succeeds
Response
[username] + setup OK. Device data for aes128 protection is switched on.
[username] + setup OK. Device data for aes128 protection is switched off.
Incorrect username or
password,
Incorrect command
[username] + command error
format
Table43: AES Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
37
www.unictron.com
www.sanav.com
The Home Unit provides OTA upgrade function. Put the upgrade file on the server and update the device through
SMS command.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「File URL」*
SMS Command: #username,0000,fota, http://220.128.123.1:30000/FW_file.txt*
SMS/ COTA Command
Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
fota
Mode “fota” defines firmware OTA setup mode.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up FOTA (Over-the-Air Technology)
http://220.128.123.1:30 File URL
000/FW_file.txt
*
End sign.
Table44: FOTA Setup Format Description
Situation
Setup Succeeds
Setup Fail
Response
[username] + , Device OTA Process Start.
[username] + , Download success. Device will start update and reboot.
[username] + , FOTA setup fail. The checksum is not correct in filename.
Incorrect username or
password,
Incorrect command
[username] + command error
format
Table45: FOTA Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
38
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up paired with the bracelet (NB5)
IDPAIR (Pair)
The Home Unit can detect if the bracelets or the extenders are in the RF Range. However, the bracelet’s HAID
and the extender’s ID should be set to the Pair-list (idpair) which is restored in the SJ-205HAB.
We send this “Idpair” command to SJ-205HAB for configuring this setting.
There are 20 sets of HAID that can be set, including bracelet’s and the extender’s.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Bracelet HAID」*
SMS Command: #username,0000,idpair,I0251*
SMS/ COTA Command
Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
idpair
Function code for pairing NB5 or SJ203RF with Home Unit
I0251
If its ID is 50, we set the I0051 there.
If its ID is 251, we set the I0251 there.
Note that there are always four digits.
*
End sign.
Table46: IDPAIR Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
39
www.unictron.com
www.sanav.com
IDUNPAIR (Unpair)
Use this “Idunpair” command to clear the pairing. For instance, when SJ-205HAB receives this command and
there is a pair number(I0251) in the Pair-list, then this pair number will be deleted.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Bracelet HAID」*
SMS Command: #username,0000,idunpair,I0251*
SMS/ COTA Command
Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
idunpair
Function code for unpairing NB5 or SJ203RF with Home Unit
I0251
If its ID is 50, we set the I0051 there.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up unpaired with the bracelet (NB5)
If its ID is 251, we set the I0251 there.
Note that there are always four digits.
*
End sign.
Table47: IDUNPAIR Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
40
www.unictron.com
www.sanav.com
Use this “Idrst” command to clear all the pairing number in the list which is restored in Home Unit.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」*
SMS Command: #username,0000,idrst*
SMS/ COTA Command
Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
idrst
Function code for clear all the pairing number in the list which is restored in Home
© Unictron Technologies Corp.
All specifications subject to change without notice.
IDRST (Clear all of the idpair at the same time)
Unit.
*
End sign.
Table48: IDRST Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
41
www.unictron.com
www.sanav.com
The Home Unit can forward RF command to set the bracelet.
SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Device ID」,「Function」,「Value」*
There are three function can use.

RT
Set transmission time frequency. Range is 1 ~ 999 sec Example:
#username,0000,rfcmd,I0251,rt,60*

PW
Set RF power. Range is 1 ~ 8 Example:
© Unictron Technologies Corp.
All specifications subject to change without notice.
RF Command
#username,0000,rfcmd,I0251,pw,8*

AC
Set alarm off function. Example:
#username,0000,rfcmd,I0251,ac*
SMS/ COTA Command
Description
#
Start sign.
USERNAME


Default ID of the device.
If you have changed the user name, please use the updated one.
0000


Default password.
If you have changed the password, please use the updated one.
rfcmd
Function Mode
I0251
If its ID is 50, we set the I0051 there.
If its ID is 251, we set the I0251 there.
Note that there are always four digits.
rt
To bracelet function
60
value
*
End sign.
Table49: RF command Setup Format Description
Situation
Response
Setup Succeeds
[username] + setup OK. TA Setting is updated.
Setup Fail
[username] + setup Fail. System Time Out.
Incorrect username or
password,
Incorrect command
[username] + command error
format
Table50: RF Command Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
42
www.unictron.com
www.sanav.com
The device reports GPRMC data to the server/cell phone normally via 3G mobile network.
When the 3G is not in service or the 3G signal strength is poor, the GPRMC data will not be able to report to the
server. They will be saved to flash memory as backup and back to the server when 3G service is recovered.
User can use this command to erase the logged (historical) GPRMC data stored at the flash memory of the
device.
Setup Format: #「USERNAME」,「Password」,「Function Mode」*
Command: #USERNAME,0000,er*
© Unictron Technologies Corp.
All specifications subject to change without notice.
Erase the Backup Data(Clear the flash memory)
Note: Erasing the flash memory takes about 90 seconds when it comes to NB5, so the reply will be a bit later
than that of other SMS commands. In generally, the reply will be received in 2-3 minutes.
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
er
Mode “er” defines the Data Erase mode.
*
End sign.
Table51: Erase the Logged Data Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
43
www.unictron.com
www.sanav.com
© Unictron Technologies Corp.
All specifications subject to change without notice.
Setup buzzing when receiving RF signal
As this feature is on, the Home Unit will generate a buzz sound while receiving RF signal. We usually use this
feature as a purpose of testing so that is easier for testers to make sure whether there is a RF connection or not.
The default setting is OFF.
Setup Format: #「USERNAME」,「Password」,「Function Mode」,「ON/OFF」*
Command: #USERNAME,0000,rfdemo,1*
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
rfdemo
Function code for toggling this feature
1
ON/OFF switch. (1: ON, 0: OFF)
*
End sign.
Table52: RFdemo Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
44
www.unictron.com
www.sanav.com
As this feature is on, the Home Unit will receive all of the bracelets nearby without pairing in advance. We
usually use this feature as a purpose of testing; therefore the default setting is OFF. Generally, we recommend
pairing the bracelet while monitoring in order to prevent from receiving unnecessary data. However, we reserve
this feature for the necessary conditions.
Setup Format: #「USERNAME」,「Password」,「Function Mode」,「ON/OFF」*
Command: #USERNAME,0000,rfall,0*
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
© Unictron Technologies Corp.
All specifications subject to change without notice.
Setup RFall feature
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
rfall
Function code for toggling this feature
0
ON/OFF switch. (1: ON, 0: OFF)
*
End sign.
Table53: RFall Setup Format Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
45
www.unictron.com
www.sanav.com
The user can set the SMS/COTA command to alert user if the battery voltage is low or automatically shut down
system when the battery voltage reaches a certain threshold .
Setup Format: #「USERNAME」,「Password」,「Function Mode」, 「Voltage Value 1」, 「Voltage Value 2」*
Command: #USERNAME,0000,LP,3650,50*
SMS/ COTA Command
Description
#
Start sign.
user name

Default ID of the device.

If you have changed the user name, please use the updated one.

Default password.

If you have changed the password, please use the updated one.
0000
Function Mode
Mode LP defines the low power alarm and device shutdown setting.
Voltage Value 1 (V1)
The range is 3500~3800, when the voltage reaches this value, the “LP” event will be
© Unictron Technologies Corp.
All specifications subject to change without notice.
Set up Low Power reminder
sent out.
Voltage Value 2 (V2)
The range is 1~99, when the voltage is lower than V1 - V2, “LP2” event will be sent
out and shut down.
*
End sign.
Table54: Low Power Setup Description
Situation
Message Reply
Setup Succeeds
[username] + setup OK. Device low power value setting is updated.
Table55: Low Power Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
46
www.unictron.com
www.sanav.com
This table shows the different events/ messages sent from the device.
There are more than 9 different situations that can trigger the device to respond to positioning commands and
tracker status messages as the following.
Note: Any event marked with the letter “B” represents data which failed to send through specified route due to
priority or mobile network service issue. Check whether the data is sent after network issues are cleared.
Event
Description
When the device is set to report to assigned route in a given period of time, it will
AUTO / BAUTO
© Unictron Technologies Corp.
All specifications subject to change without notice.
Appendix 1: Tracker Event List
send a report automatically with an AUTO message.
When any other event is triggered and the priority is greater than AUTO, the
Retrospective Location report will be backed up and reported to assigned route later.
POLL / BPOLL
When sending polling command to poll the report, it triggers the POLL event.
LP2
When the equipment is in the lowest power, it triggers the “LP2” event.
TT
MT
PLUG
When the residential equipment tamper switch is detected, it triggers the “TT”
event.
When the residential equipment is moved, it triggers the “MT” event.
When the equipment is plugged in charger for more than 10 seconds, it triggers the
“PLUG” event.
UNPLUG
When the equipment is unplugged from charger, it triggers the “UNPLUG” event.
CHOK
When the equipment is full charged, it triggers the “CHOK” event.
RFIN
When the equipment is receiving RF signal from bracelet, it triggers the “RFIN”
event.
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
47
www.unictron.com
www.sanav.com
1
2
3
4
5
6
7
8
HAB
357042062420808
$GPRMC
132152
A
2458.973
N
12125.66
HAB
357042062420808
$GPRMC
134914
A
2458.973
N
12125.66
9
10
11
12
E
0
0
300620
A*46
E
0
0
300620
A*4A
16
17
18
19
13
14
20
AUTO
RFIN
I0001
19
8
-74
15
21
22
23
N0000
M18
4079mV
N0006
M19
4087mV
Field Description
Field
Description
1
Device Type
16
Event
2
GSM IMEI
17
RF Identification number
3
Log header
18
RF Tag Event ; see appendix 3
4
UTC Time ; 11:08:57.000 (GMT+0)
19
RF Tag RF Power Indicator
5
validity - A-ok, V-invalid
20
RF Sensitivity
6
current Latitude
21
Report Counter
7
North / South
22
GSM Sensitivity
8
current Longitude
23
Battery Voltage
9
East / West
10
Speed in knots
11
True course
12
Date : Day, Month, Year
13
Magnetic variation, degrees (No use)
14
Magnetic variation direction E/W (No use)
15
Positioning system mode indicator* checksum
© Unictron Technologies Corp.
All specifications subject to change without notice.
Appendix 2: Report Data Output Format
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
48
www.unictron.com
www.sanav.com
1(hexadecimal)
9(hexadecimal)
0
0
0
1
1
0
0
1
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
if charge not
LP2
completed
(Extremely
FBR (Strap
ACK bit
Device
Tamper)
(Reserved)
Tamper
UNPLUG
(Disconnect
from main
power)
Charging
when unplug Low Power)
Low Battery
© Unictron Technologies Corp.
All specifications subject to change without notice.
Appendix 3: NB5 & RF Within SJ-205HAB Range(RF Tag event)
Example:
RF Tag event
Description
00
Normal
01
NB5 Low Battery (Low Power)
02
NB5 Device Tamper
08
NB5 Strap Tamper
80
Charging Complete
C0
Charging Not Complete
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
49
www.unictron.com
www.sanav.com
Warranty Time Period and Repair Coverage
SAN JOSE TECHNOLOGY, INC. provides a 1-year (12-month) product warranty for SANAV products
purchased directly from SAN JOSE Technology or authorized dealers effective from date of unit
purchase. If the equipment is defective or malfunctions during the 1-year warranty period, SAN
JOSE Technology will either repair or replace the unit free of charge for the customer. SANAV’s
repair service will include necessary adjustments, remanufacturing, and replacements. The
product will be returned by freight shipping prepaid by the customer within valid warranty period.
Notice that you must contact SAN JOSE Technology, Inc. for a valid RMA (Return Material
Authorization) number before returning the goods for repair.
In order to expedite the SANAV repair process, customers will complete a detailed symptom
© Unictron Technologies Corp.
All specifications subject to change without notice.
Warranty Regulation
description of each unit for RMA..
Service assistance by phone is also provided during the warranty period.
Limitations
This warranty is limited only to the repair or replacement of defective parts confirmed by SAN JOSE Technology
to be a result of faulty materials or workmanship. Instruments mechanically or physically damaged due to the
following conditions are beyond our warranty:
1.
Neglect, misuse, or abuse, such as incorrect testing, installation, or operation.
2.
Placement of unit in extreme environments beyond the limits of the specifications.
3.
Subjugation of unit to disassembling, soldering, alteration, unauthorized repair and electrical
shock by nature.
4.
Any incidental or consequential losses or damages resulting from the purchase.
5.
Disaster, accidents, use of any inauthentic substitutive equipment, or loss of any accessory that
is not provided by SAN JOSE Technology.
For damages caused under the above conditions, we'll contact you to discuss replacement options.
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|[email protected]
50
www.unictron.com
www.sanav.com
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation. Changes or
modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
·
Reorient or relocate the receiving antenna.
·
Increase the separation between the equipment and receiver.
·
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
·
Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in
portable exposure condition without restriction.
Specific Absorption Rate (SAR) information:
This SJ-205HAB meets the government's requirements for exposure to radio waves. The guidelines
are based on standards that were developed by independent scientific organizations through periodic
and thorough evaluation of scientific studies. The standards include a substantial safety margin
designed to assure the safety of all persons regardless of age or health. FCC RF Exposure Information
and Statement the SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device
types: Tablet has also been tested against this SAR limit. This device was tested for typical body-worn
operations with the back of the phone kept 0mm from the body. To maintain compliance with FCC
RF exposure requirements, use accessories that maintain an 0mm separation distance between the
user's body and the back of the phone. The use of belt clips, holsters and similar accessories should
not contain metallic components in its assembly. The use of accessories that do not satisfy these
requirements may not comply with FCC RF exposure requirements, and should be avoided.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement