User - Manual

SECOM 737CE

 Copyright 2009 SETEX Schermuly textile computer GmbH

SETEX

Schermuly textile computer GmbH

Hauptstr. 23–25

35794 Mengerskirchen

Germany

Version 1.94/01 (date 15.01.2010).

The content of this user manual is subject to changes without notice.

This user manual may contain copyright information. No part of this manual should be copied or duplicated without the written approval from SETEX.

Document number: 737CE-KE

A-001-0194-1

Article number: SD2125001

Schermuly textile computer 2008

EG declaration of conformity for the CE marking

Product (s) Industrial PC

SECOM 737CE

If used as directed the indicated product is in line with the regulation of the following European

Directives:

93/68/EWG Directive for CE Marking

89/336/EWG

73/23/EWG

Directive for Electromagnetic Compatibility (EMC)

Low Voltage Directive (LVD)

The conformity of the indicated product with the regulations of the above-mentioned directives is proven by the compliance with the following harmonised standards:

Emitted Interference:

Interference resistance:

DIN EN 55022 (09/03), DIN EN 61000-6-4 (08/02)

DIN EN 61000-6-2 (08/02)

Security: DIN EN 60950-1 (03/03)

Oliver Schermuly

Managing Director for

SETEX Schermuly textile computer GmbH

Hauptstraße 23–25

35794 Mengerskirchen

Germany

Safety advices

General notice

Several icons are used in this manual to point out warnings, possible errors and hints. The icons have the following meanings:

Reference

This icon is used for general references.

Attention

Parts in the manual marked with this symbol refer to possible error conditions or dangerous situations that might occur when working with the controller.

Warning

This symbol is used to point out dangers for the user’s health.

Safety advices S-I

Safety advices

The operating instructions should be read carefully before installing and setting the controller into operation. Wrong handling can lead to injuries and/or damages of equipment.

The proper and safe function of the controllers requires a correct transport and storage of the equipment as well as a professional installation and maintenance.

In principle, electronic appliances are not fail-safe. The user must take care that the machine is in a safe mode if a failure on the controller occurs. Otherwise, this could cause injuries to persons or damages to the equipment

When opening covers or removing parts from the controller, parts connected to the supply voltage may be uncovered and could be touched. Before working on it or exchanging parts of the controller, if it becomes necessary to open the controller’s housing, the controller must be disconnected from power. Repairs of the controller which have to be done while the housing is open while power is applied to the controller, this must only be done by trained and qualified personnel..

If one can assume that a safe operation is no longer possible, the appliance must be switched off. Make sure that it cannot be switched on accidentally in this case.

It can be assumed that a safe operation is no longer possible in the following conditions,

− If there are visible damages on the controller,

− If the controller does not work,

− If the controller has been stored under inadequate conditions for a longer period of time,

− After unsuitable transportation conditions.

S-II Safety advices

Safety advices

Safety advices

1. General information

During operation, the SECOM controllers might have – corresponding to their protection class – parts with live voltages, hot surfaces or eventually moving parts.

There is a risk of injuries to persons and damages of the equipment if the protective covers are opened, if the controller is not properly installed or when operating errors occur.

You will find more information on this subject in the documentation.

All work in regard to the transport, the installation, the setting into operation and the maintenance should be done by authorized and qualified personnel only (the relevant IEC-,

DIN-, VDE- and national regulations for prevention of accidents and electrical hazards must be observed).

Qualified personnel in this sense are persons who are familiar with the installation, the mounting, the setting into operation and the operation of the controller and who possess the qualifications related to their profession.

2. Use of the controllers

The SECOM controllers are electrical equipment for the installation in control cabinets of electrical facilities or machines.

Please find the technical data and the information on the connection of the controller in the documentation. These instructions must strictly be observed.

3. Transport, storage

Please observe the advice for the transport, the storage and the proper handling of the controllers.

4. Installation

The installation and measures for adequate air ventilation of the controllers must be done in accordance with the instructions in the related documentation.

Make sure that no components are bend during transport and handling. Avoid touching the electrical components and contacts.

S-III

Safety advices

5. Electrical connection

The electrical installation has to be done according to the relevant regulations (e. g. wire cross section, fuse protection, protective conductor connection etc.). Advice about this matter is included in the documentation.

6. Operation

Production facilities with integrated computer controllers must be equipped in certain cases with additional supervising and protective equipment in accordance with the relevant safety regulations, regulations for prevention of accidents, etc.

The machine construction must include measures limiting the consequences of a malfunction or a damage of the controller in order to avoid injuries to persons or damages to the equipment.

All covers and doors must be shut during the operation.

These safety instructions must be kept!

Please observe also the specific safety instructions and the operating instructions.

S-IV Safety advices

Table of contents

Chapter 1 ..................................................................................................... 1-1

INTRODUCTION 1-1

1 GENERAL INFORMATION ........................................................... 1-2

2 OPERATION ................................................................................. 1-3

2.1

O

PERATING ELEMENTS

.............................................................. 1-4

2.1.1

Program function keys ...................................................... 1-4

2.1.2

Special function keys / Hot keys (with LED) ...................... 1-4

2.1.2.1

Lock key .............................................................................. 1-5

2.1.2.2

Alarm key ............................................................................ 1-6

2.1.2.3

Operator call key ................................................................. 1-6

2.1.2.4

Addition key ......................................................................... 1-7

2.1.2.5

Manual operation key .......................................................... 1-7

2.1.3

Start-key ........................................................................... 1-8

2.1.4

Stop-key ............................................................................ 1-8

2.1.5

Numeric keypad ................................................................ 1-8

2.1.6

Cursor keys ....................................................................... 1-8

2.1.7

Other function keys ........................................................... 1-9

2.2

D

ISPLAY

................................................................................. 1-10

2.2.1

Display layout ................................................................. 1-10

2.2.1.1

Status-line ......................................................................... 1-10

2.2.1.2

Program status .................................................................. 1-11

2.2.1.3

Process information ........................................................... 1-12

2.2.1.4

Batch information window .................................................. 1-12

2.2.1.5

Program function key line .................................................. 1-13

2.2.2

Message windows........................................................... 1-17

2.2.3

Startup screen ................................................................ 1-18

Chapter 2 ................................................................................................... 2-19

EDITING PROGRAMS 2-19

3 BASIC INFORMATION ............................................................... 2-21

3.1

P

ROGRAM STRUCTURE

............................................................ 2-21

3.1.1

Functions ........................................................................ 2-21

3.1.1.1

Main functions ................................................................... 2-22

3.1.1.1.1

System functions .......................................................... 2-23

3.1.1.2

Parallel functions ............................................................... 2-25

4 CREATING A PROGRAM .......................................................... 2-26

4.1

E

NTERING THE PROGRAM HEADER

............................................ 2-27

4.2

E

NTERING PROGRAM STEPS

..................................................... 2-28

4.2.1

Programming main functions .......................................... 2-29

4.2.2

Programming parallel functions ...................................... 2-33

4.2.2.1

More than 8 parallel function groups.................................. 2-34

4.3

S

AVING PROGRAM STEPS

......................................................... 2-35

4.4

S

AVING PROGRAMS

................................................................. 2-35

737CE/1.94/01 Table of contents i

Table of contents

5 MODIFYING PROGRAMS .......................................................... 2-36

5.1

S

ELECTING A PROGRAM

........................................................... 2-37

5.2

C

HANGING PROGRAM NAMES AND COMMENTS

............................ 2-38

5.3

M

ODIFYING A PROGRAM STEP

................................................... 2-39

5.3.1

Modifying the main function parameters ......................... 2-40

5.3.2

Exchange/delete main functions ..................................... 2-40

5.3.3

Edit parallel functions ...................................................... 2-40

5.3.3.1

Change parameters of parallel functions ........................... 2-41

5.3.3.2

Delete parallel functions .................................................... 2-41

5.3.3.3

Program new parallel functions ......................................... 2-41

5.4

I

NSERTING A PROGRAM STEP

.................................................... 2-42

5.5

D

ELETING A PROGRAM STEP

..................................................... 2-43

6 COPYING A PROGRAM ............................................................. 2-44

6.1

C

OPYING A PROGRAM ON THE CONTROLLER

.............................. 2-45

6.2

C

OPY TO AN EXTERNAL DRIVE

.................................................. 2-47

6.2.1

Copy via USB (USB memory sticks) ............................... 2-47

6.2.2

Copy via the network (host operation) ............................ 2-49

6.3

C

OPYING ALL PROGRAMS

(

BACKUP

) .......................................... 2-49

6.4

C

OPY MESSAGES

.................................................................... 2-50

7 DELETING A PROGRAM ........................................................... 2-51

8 ADDITION TREATMENT ............................................................ 2-53

8.1

M

ARKING THE ADDITIONS

......................................................... 2-53

8.2

P

ROGRAM STRUCTURE OF ADDITION TREATMENTS

..................... 2-54

8.3

C

REATING AN ADDITION TREATMENT

......................................... 2-54

8.4

D

EFINING ADDITION TEXTS

....................................................... 2-56

9 VARIABLE FUNCTION PARAMETER ....................................... 2-57

9.1

D

EFINITION OF VARIABLE FUNCTION PARAMETERS

/

FORMULAS

.... 2-57

9.2

E

DITING VARIABLE FUNCTION PARAMETERS

............................... 2-58

Chapter 3 ................................................................................................... 3-61

OPERATION 3-61

10 STARTING A BATCH ................................................................. 3-63

10.1

G

ENERAL

I

NFORMATION

........................................................... 3-63

10.2

O

PENING THE BATCH CREATION WINDOW

................................... 3-64

10.3

P

ROGRAM SELECTION

.............................................................. 3-65

10.3.1

Selection list .................................................................... 3-65

10.3.2

Entering the program number ......................................... 3-66

10.4

E

DITING BATCH INFORMATION

................................................... 3-67

10.4.1

Entering batch texts ........................................................ 3-67

10.4.2

Entering batch parameters .............................................. 3-68

10.5

B

ATCH PROGRAM GENERATION

................................................. 3-69

10.6

S

TARTING THE PROGRAM

......................................................... 3-70

10.6.1

Possible errors when starting the program ..................... 3-70

10.7

B

ATCH LIST

............................................................................. 3-71

10.7.1

Loading an OrgaTEX batch ............................................ 3-73

ii

Table of contents 737CE/1.94/01

Table of contents

11 THE PROGRAM IS RUNNING .................................................... 3-74

11.1

D

ISPLAY STATUS LINE

.............................................................. 3-74

11.2

D

ISPLAY OF FUNCTIONS

........................................................... 3-74

11.2.1

Display of actual values .................................................. 3-74

11.2.2

Main functions ................................................................. 3-75

11.2.3

Parallel functions ............................................................ 3-75

11.2.3.1

Display of parallel function parameters .............................. 3-76

11.3

M

ANUAL

I

NTERVENTION

........................................................... 3-77

11.3.1

Manual intervention by pressing the hot key ................... 3-77

11.3.1.1

Changing the actual main function and its parameters ...... 3-78

11.3.1.2

Changing the parallel functions and their parameters ........ 3-78

11.3.1.3

Return to the automatic mode ........................................... 3-79

11.3.1.4

Changing the program steps ............................................. 3-79

11.3.2

Some explanations ......................................................... 3-80

11.4

D

ISPLAY OF OPERATOR CALLS

.................................................. 3-81

11.4.1

Operator call “Sample” .................................................... 3-81

11.4.1.1

Sample is O.K. .................................................................. 3-81

11.4.1.2

An addition is required ....................................................... 3-82

11.4.1.3

Possible errors .................................................................. 3-83

11.4.1.4

Select a certain step for an addition .................................. 3-84

11.5

P

ROGRAM END

........................................................................ 3-84

12 INTERRUPTING A PROGRAM .................................................. 3-85

12.1

P

RESSING THE STOP BUTTON

................................................... 3-85

12.2

S

TOP

-

ALARM

.......................................................................... 3-85

12.3

P

OWER FAILURE

...................................................................... 3-86

12.4

R

ESTARTING THE PROGRAM

..................................................... 3-86

13 MANUAL OPERATION MODE ................................................... 3-88

13.1

C

ONDITIONS

........................................................................... 3-88

13.2

H

OW TO ACTIVATE THE MANUAL OPERATION MODE

? ................... 3-88

13.3

H

OW TO LEAVE THE MANUAL OPERATION MODE

? ........................ 3-89

Chapter 4 ................................................................................................... 4-91

BATCH INFORMATION 4-91

14 INFO-MENU ................................................................................ 4-92

14.1

P

ROCESS INFORMATION

........................................................... 4-92

14.2

A

LARM LIST

............................................................................. 4-93

14.3

E

VENT LIST

............................................................................. 4-95

14.4

H

ISTORY

................................................................................ 4-96

14.4.1

Batch selection ............................................................... 4-97

14.4.2

Display of process values ............................................... 4-97

14.4.3

Copy historical batch data ............................................. 4-100

14.4.3.1

Only one batch ................................................................ 4-100

14.4.3.2

All batches ....................................................................... 4-101

14.5

P

ROGRAM LIST

...................................................................... 4-102

14.6

B

ATCH INFO

.......................................................................... 4-104

737CE/1.94/01 Table of contents iii

Table of contents

Chapter 5 ................................................................................................. 5-105

MESSAGES 5-105

15 ALARMS ................................................................................... 5-106

15.1

A

LARM DISPLAY

..................................................................... 5-106

15.1.1

Alarm list ....................................................................... 5-108

15.2

S

TARTING THE CONTROLLER AFTER ALARMS OCCURRED

........... 5-110

15.2.1

Start the controller after a stop alarm ............................ 5-110

15.2.2

Start the controller after a hold alarm ............................ 5-110

15.3

A

LARM CLASSIFICATION

......................................................... 5-111

15.3.1

User alarms .................................................................. 5-111

15.3.2

Controller and measurement system alarms ................ 5-111

15.3.3

System alarms of the SECOM ...................................... 5-112

15.3.4

System alarms of the PLC ............................................ 5-117

iv

Table of contents 737CE/1.94/01

Introduction

Chapter 1

1 GENERAL INFORMATION ........................................................... 1-2

2 OPERATION ................................................................................. 1-3

2.1

O

PERATING ELEMENTS

.............................................................. 1-4

2.1.1

Program function keys ...................................................... 1-4

2.1.2

Special function keys / Hot keys (with LED) ...................... 1-4

2.1.2.1

Lock key .............................................................................. 1-5

2.1.2.2

Alarm key ............................................................................ 1-6

2.1.2.3

Operator call key ................................................................. 1-6

2.1.2.4

Addition key ......................................................................... 1-7

2.1.2.5

Manual operation key .......................................................... 1-7

2.1.3

Start-key ........................................................................... 1-8

2.1.4

Stop-key ............................................................................ 1-8

2.1.5

Numeric keypad ................................................................ 1-8

2.1.6

Cursor keys ....................................................................... 1-8

2.1.7

Other function keys ........................................................... 1-9

2.2

D

ISPLAY

................................................................................. 1-10

2.2.1

Display layout ................................................................. 1-10

2.2.1.1

Status-line ......................................................................... 1-10

2.2.1.2

Program status .................................................................. 1-11

2.2.1.3

Process information ........................................................... 1-12

2.2.1.4

Batch information window .................................................. 1-12

2.2.1.5

Program function key line .................................................. 1-13

2.2.2

Message windows........................................................... 1-17

2.2.3

Startup screen ................................................................ 1-18

737CE/1.94/01 Introduction

1-1

Chapter 1

Features

1 General information

The program controller SECOM is an industrial PC designed and developed for applications in the textile-finishing field.

The most important feature for the operator is the graphical user interface using

Windows CE. It allows the user to get acquainted with the system in a fast and comfortable way.

The SECOM can be used as a single program controller as well as in a PC network.

Application

Safety concept

The main field of operation for the SECOM is the automation of all discontinuous, program-controlled processes in a dye house.

Due to its flexibility and the possibility to be adapted to various systems, the program controller can be applied to all production and laboratory facilities of wet finishing, like e. g:

Jet

Jigger

Beam machine

Yarn machine

Foulard

Programs installed on the SECOM can be saved on a USB memory stick and can be transferred to other machines or, if necessary, copied back to the controller.

The important machine related information stored on the SECOM like:

• Machine functions

• Configuration are saved on a CompactFlash disk which is plugged into the SECOM.

The safety concept of the controller includes a power-fail recognition, which ensures that the SECOM will be in a safe mode in case of power failure.

After restarting the controller the SECOM automatically returns to the interrupted program step and can be restarted at that point.

Alarm processing

Failures that occur during the operation of the SECOM are announced by a displayed text and are recorded at the same time.

Depending on the severity of the failure, the alarms may stop or interrupt the running process.

There are different alarms announcing different failures:

• Machine specific alarms

• System alarms of SECOM

• System alarms of the connected PLCs

1-2

Introduction 737CE/1.94/01

Introduction

2 Operation

Due to the various possibilities offered by a PC based controller, the operation of the

SECOM is very easy and is achieved by using only a few operating elements.

At the bottom of the screen the current available functions of the 4 function keys (F1 to

F4) are displayed.

Below the function keys you can find additional keys, so-called “Hot-Keys”. They are used to open certain windows directly or to start certain actions.

Further below to the left there is the numerical keyboard. To the right you find keys to start and stop the controller, cursor keys, page-up and page-down keys as well as

ESC, Alt, backspace and OK (Enter) keys which functions are similar to those on a normal PC.

On the left side of the SECOM you will find a USB port that can be used for USB memory sticks, keyboards etc. A cover closes it.

SECOM 737CE

Picture 2-1:

Front view

USB connector

737CE/1.94/01 Introduction

1-3

Chapter 1

2.1 Operating elements

Picture 2-2: Example program- function key line

2.1.1 Program function keys

The keys F1 to F4 are not fixed assigned to special program functions.

The current functions of each of these four keys are displayed in the lower part of the screen (function key line).

2.1.2 Special function keys / Hot keys (with LED)

Picture 2-3: Special function keys (Hot

Keys)

With the help of the special function keys it is possible to open certain windows directly or to start certain program actions.

1-4

Introduction 737CE/1.94/01

Introduction

2.1.2.1 Lock key

Setting up different authorization level can restrict the access to different operations, like e.g. program editor, manual operation or the configuration menu.

To get access to the different authorization levels, a pass-code must be entered after pressing the lock key.

After the lock key is pressed, a window is displayed in which the pass-code has to be entered.

After having entered the

numeric code (max. 8 digits)

and after having confirmed the input with the OK key, the window will be closed and access to the corresponding level is granted.

Picture 2-4: Window for pass-code input

The code entered is displayed as

********

.

A yellow LED in the lock key indicates that the program lock has been opened.

In case you do not wish to enter a pass-code, the window can be closed by pressing the Esc key.

If the lock key is pressed again, the access rights to the selected level will be removed.

The yellow LED is switched off.

In case that a wrong pass-code has been entered the following message will be shown.

Picture 2-5:Wrong code

After pressing the OK key, this window will be closed and the pass-code can be entered again.

737CE/1.94/01 Introduction

1-5

Chapter 1

2.1.2.2 Alarm key

The red LED is flashing when a stop alarm occurs.

The red LED is on when an info alarm or a hold alarm occurs.

Press the alarm key to close the alarm window and to quit the alarm.

See also chapter 5, item 15.1 Alarm display, on page 5-106.

If the alarm key is pressed in the main or in a selection menu, the alarm list will be displayed (this is the Hot key for the alarm list of the info menu).

See also chapter 4, item 14.2 Alarm list, on page 4 -93.

2.1.2.3 Operator call key

The yellow LED is flashing when an operator call occurs.

This key has different functions depending on the current controller mode:

• If the operator call window is active:

The operator call will be confirmed.

• If a function stop (like e. g. load/unload, chemicals, color, sample) is active:

The function or the step is confirmed, provided that the step confirmation has been initiated and the system constant no. 47 ”mode operator call key” is set to 1.

• If the controller is in any other state like than the two described above and if it is in the main menu, in a selection menu or in the alarm list:

The process picture No. 9 will be displayed provided that it has been configured.

As per definition, this process picture should contain time- and batch information for the operator.

(see chapter 4, Picture 14-3, on page 4-93

1-6

Introduction 737CE/1.94/01

Introduction

2.1.2.4 Addition key

The yellow LED is flashing if the controller is in ”RUN” mode and in function

”SAMPLE”, and provided that the addition selection has been enabled.

The yellow LED is on while the addition function is running (if the addition is finished it jumps back to the sample step it came from) and is switched off as soon as the sample function has been confirmed.

This key has different functions depending on the current controller mode:

• If the operator call window is active:

The operator call will be confirmed.

• Function ”Sample” is active:

When pressing the addition key, the window for the addition selection will be displayed (this is the Hot key for the addition selection).

See also chapter 3, item 11.4.1.2 An addition is required, on page 3-82.

If the system constant 28, addition key, is set to 1 and the controller is in any other state as mentioned above, then the extended program list will be shown if the button is pressed.

2.1.2.5 Manual operation key

During manual operation, the yellow LED is flashing.

After pressing this key, the window with the manual operation editor will be displayed

(this is the Hot key for manual operation).

See also chapter 3, item 11.3.1 Manual intervention , on page 3-77.

737CE/1.94/01 Introduction

1-7

Chapter 1

2.1.3 Start-key

Press the green start key to start a selected program or to continue an interrupted program.

”RUN” is displayed in the status line and the green LED is on.

2.1.4 Stop-key

Press the red stop key to interrupt the running program.

“BREAK” is displayed in the status line. The green start key LED is off.

Picture 2-6: Numeric keypad

2.1.5 Numeric keypad

The numeric keys are used to enter the numbers when editing programs.

The numeric keys can also be used as a shortcut to select function groups and functions during programming as well as to open an info window of the parallel functions from the main menu.

Picture 2-7:

Cursor keys

2.1.6 Cursor keys

The cursor keys are used to select an element in a selection window.

Within a list window, these keys are used to scroll up or down line by line.

If the main window is shown and the controller is in the “STOP” state then the cursor keys can be used to scroll through the program step by step.

1-8

Introduction 737CE/1.94/01

Introduction

2.1.7 Other function keys

Esc-key

Press the ”Esc” key to cancel your entries or to close open windows.

Backspace (delete) key

In an active input field, characters and numbers can be deleted one by one by pressing the ”Backspace” key.

Alt-key

This key is used to open various windows.

OK key

This key has the same function as ”Enter” key of a standard PC.

Any input into a programmable field has to be confirmed by pressing OK.

If you are in a selection or list window you have to press the OK key to confirm the selection made with the cursor keys.

737CE/1.94/01 Introduction

1-9

Chapter 1

Picture 2-8:Main menu

2.2 Display

The LCD-screen works in VGA mode with a resolution 640x480 pixel and 256 colors.

2.2.1 Display layout

The display content is composed from a status line, function key information and areas for the function display, step list and batch process information.

Depending on the situation additional windows will be opened and messages will be shown. Also the operator can open other pictures, lists and information windows.

2.2.1.1 Status-line

Picture 2-9: Example

Status line

This line includes the following information from left to right:

• Temperature symbol (can also be configured to show other symbols/icons)

• Actual temperature value of the main tank (can also be configured to show other values)

• Time symbol (can also be configured to show other symbols/icons)

• Remaining time for the current main function if applicable (can also be configured to show other values)

1-10

Introduction 737CE/1.94/01

Introduction

• Program name of the actual running program or alarm number and total number of all active alarms (if any)

• Status of the controller/dye process

• Program No. of the actual running or of the last running program

• Actual program-step number

If an alarm is active the alarm number will be shown.

Alarm display

Picture 2-10:

Example Alarm display

If more than one alarm is active, the alarm number with the highest priority will be displayed and the total number of all active alarms is shown.

Picture 2-11:

Example Alarm display

2.2.1.2 Program status

The controller can be in one of the following states:

• SELECT ⇒ No batch (program) has been selected

• READY

• RUN

• BREAK

• END

• HOLD

⇒ A batch (program) is selected but has not been started yet

⇒ A batch (program) is running

⇒ A batch (program) is interrupted (by stop key or stop alarm)

⇒ A batch (program) has been finished

⇒ A batch (program) is on hold (hold alarm)

• INTERVENT ⇒ Manual intervention is active

• MANUAL ⇒ Manual operation mode is active, controller in STOP mode

• MAN ACTIVE ⇒ Manual operation mode is active, controller in RUN mode

737CE/1.94/01 Introduction

1-11

Chapter 1

2.2.1.3 Process information

The middle part of the screen shows information about the actual running program respectively of the actual running batch and of the dye process in general. This part of the screen is divided into four sections.

The upper left section shows the active main and parallel functions with the related icons. For the main function the function set and actual parameters are shown. For the parallel functions the set values are shown. By pressing the related numerical key a window is opened that shows the set as well as the actual parameters of the parallel functions.

Picture 2-12:

Function display, main and parallel functions

The middle right section shows the step list of the dye program from the actual batch.

The actual processed step is marked with a blue line. Selecting the program list with the cursor keys followed by the OK key will open a larger, more detailed list screen.

Picture 2-13:

Display of the step list, step 3 is active

2.2.1.4 Batch information window

The batch information window can optionally be configured to show batch information, time information and process information etc. of the actual running batch.

Picture 2-14: Batch information window

1-12

Introduction 737CE/1.94/01

Introduction

2.2.1.5 Program function key line

Located in the lower part of the screen is the function key line. Via the keys certain program functions can be started or menus can be opened.

Picture 2-15: Example program function key line

The actual valid function for the keys F1...F4 is displayed program controlled in the function key line.

Picture 2-16:

Example for an opened menu

The functionality of the function keys as well as the contents of the menus can be different according to the state of the controller.

The various menu entries can be selected via the cursor keys followed by pressing

OK.

On the following page you will find an overview over the menu structure and the menu items.

737CE/1.94/01 Introduction

1-13

Chapter 1

1-14

Introduction 737CE/1.94/01

Introduction

737CE/1.94/01 Introduction

1-15

Chapter 1

1-16

Introduction 737CE/1.94/01

Introduction

2.2.2 Message windows

Message windows are displayed on the SECOM providing information and guidance for the user. They point out different events or necessary steps to be taken. Each message window includes a message text as well as an icon. The icon shows the kind of displayed message.

The following information is shown in the message windows:

Inquiries

Inquiries are mostly used for the interactive user guidance, to guide the user step by step through the necessary measures or to point out different possible measures to be taken. Messages, which include an inquiry, are marked with a question mark (general inquiries) or an exclamation mark (safety inquiries).

Process messages

Process messages are generated by the PLC program and include certain information for the user, like e. g. ”Color kitchen ready”. Process messages are marked with the caution sign. In addition, the number of the process message is shown as well.

Alarms

Alarm messages point out errors or faults within the process or within the system.

There are 3 different kinds of alarms.

1. Info alarms

2. Hold alarms

3. Stop alarms

Info and hold alarms, like e.g. ”Motor protection addition tank pump” are marked with a warning sign. A stop alarm, like e.g. ”PLC communication error” is marked with a stop sign. The alarm number as well as the alarm text is shown.

Error messages

Error messages of the system software point out illegal actions or malfunctions within the system, like e.g. ”Program not found”. These messages are marked with a caution sign.

737CE/1.94/01 Introduction

1-17

Chapter 1

Picture 2-17:

Example of a startup screen

2.2.3 Startup screen

After the SECOM is switched on and Windows CE is started the startup screen is shown during the initialization of the SECOM application software.

Depending on the supplier of the controller, the screen may look different.

After the application software is running the screen changes to the main window automatically.

1-18

Introduction 737CE/1.94/01

Editing programs

Chapter 2

3 BASIC INFORMATION ............................................................... 2-21

3.1

P

ROGRAM STRUCTURE

............................................................ 2-21

3.1.1

Functions ........................................................................ 2-21

3.1.1.1

Main functions ................................................................... 2-22

3.1.1.1.1

System functions .......................................................... 2-23

3.1.1.2

Parallel functions ............................................................... 2-25

4 CREATING A PROGRAM .......................................................... 2-26

4.1

E

NTERING THE PROGRAM HEADER

............................................ 2-27

4.2

E

NTERING PROGRAM STEPS

..................................................... 2-28

4.2.1

Programming main functions .......................................... 2-29

4.2.2

Programming parallel functions ...................................... 2-33

4.2.2.1

More than 8 parallel function groups.................................. 2-34

4.3

S

AVING PROGRAM STEPS

......................................................... 2-35

4.4

S

AVING PROGRAMS

................................................................. 2-35

5 MODIFYING PROGRAMS .......................................................... 2-36

5.1

S

ELECTING A PROGRAM

........................................................... 2-37

5.2

C

HANGING PROGRAM NAMES AND COMMENTS

............................ 2-38

5.3

M

ODIFYING A PROGRAM STEP

................................................... 2-39

5.3.1

Modifying the main function parameters ......................... 2-40

5.3.2

Exchange/delete main functions ..................................... 2-40

5.3.3

Edit parallel functions ...................................................... 2-40

5.3.3.1

Change parameters of parallel functions ........................... 2-41

5.3.3.2

Delete parallel functions .................................................... 2-41

5.3.3.3

Program new parallel functions ......................................... 2-41

5.4

I

NSERTING A PROGRAM STEP

.................................................... 2-42

5.5

D

ELETING A PROGRAM STEP

..................................................... 2-43

6 COPYING A PROGRAM ............................................................. 2-44

6.1

C

OPYING A PROGRAM ON THE CONTROLLER

.............................. 2-45

6.2

C

OPY TO AN EXTERNAL DRIVE

.................................................. 2-47

6.2.1

Copy via USB (USB memory sticks) ............................... 2-47

6.2.2

Copy via the network (host operation) ............................ 2-49

737CE/1.94/01 Editing programs

2-19

Chapter 2

6.3

C

OPYING ALL PROGRAMS

(

BACKUP

) .......................................... 2-49

6.4

C

OPY MESSAGES

.................................................................... 2-50

7 DELETING A PROGRAM ........................................................... 2-51

8 ADDITION TREATMENT ............................................................ 2-53

8.1

M

ARKING THE ADDITIONS

......................................................... 2-53

8.2

P

ROGRAM STRUCTURE OF ADDITION TREATMENTS

..................... 2-54

8.3

C

REATING AN ADDITION TREATMENT

......................................... 2-54

8.4

D

EFINING ADDITION TEXTS

....................................................... 2-56

9 VARIABLE FUNCTION PARAMETER ....................................... 2-57

9.1

D

EFINITION OF VARIABLE FUNCTION PARAMETERS

/

FORMULAS

.... 2-57

9.2

E

DITING VARIABLE FUNCTION PARAMETERS

............................... 2-58

2-20

Editing programs 737CE/1.94/01

3 Basic information

3.1 Program structure

Programs, which are edited and run on a controller, consist of a program header and sequential program steps.

For program administration so-called header information data is required for each program.

This information includes:

• Program number

• Program name

• Comments

• Date of creation

• Date of last change

• Number of steps

Each program step consists of a main function and up to 12 parallel functions.

The main functions control the main process, i.e. related to the main tank of the dyeing machine.

The peripheral equipment of the machine, like preparation tank, addition tanks, color kitchen tanks, pumps etc., are controlled by the parallel functions.

3.1.1 Functions

The SECOM offers a function range that suits all kind of dyeing machines.

Each function has a specific function name, function graphics and several parameters.

All functions of a specific type (like rinsing) are grouped together for an easy reference.

Editing programs

737CE/1.94/01 Editing programs

2-21

Chapter 2

Main function groups

Assignment of main functions

3.1.1.1 Main functions

The main functions control the processes, which are directly related to the dyeing machine.

All machine functions of the same type are grouped together in main function groups.

Each function group includes a function group text and an icon.

The following main functions are included in the standard configuration:

• System

• Filling

• Rinsing

• Draining

• Dosing/inject Add1

• Dosing/inject Add2

• Operator Call

• Dyeing

You will find a detailed description of all the functions in a separate list.

During the project work for your machine, the required main function groups are selected. If necessary, new groups can be added. A maximum of 8 functions can be assigned to each group.

Only the functions that have been selected will be visible during the programming and the production process.

2-22

Editing programs 737CE/1.94/01

3.1.1.1.1 System functions

Among the main functions, the systems functions have a special purpose.

These functions do not control the machine but are used to trigger certain actions in the SECOM.

The following system functions are implemented in the SECOM:

Program-start

This function must be programmed in the first program step.

The program start function initializes the controller in order to start a new batch.

After the program is started, the function is confirmed automatically by the PLC and the program advances to the next step.

Program-end

This function must be programmed in the last program step.

The program end function stops the program and the mode of the controller changes to “END”.

After that it is not possible anymore to start the program of the current batch again.

No operation

This function is needed when a step consists of parallel functions only and does not include any main function.

The step confirmation then depends on the programmed parallel functions.

Addition start

This function marks an addition start within a program.

Each addition must be started with this function.

When an addition is started, this function will automatically be confirmed and the program advances to the next step.

Addition end

This function is programmed at the end of an addition.

Each addition must be finished with this function.

When an addition is processed and reaches addition end, the function will automatically be confirmed and the program returns to the “SAMPLE” step it came from.

Editing programs

737CE/1.94/01 Editing programs

2-23

Chapter 2

Jump

This function is used to skip parts of the program or to program a loop. A label function is used as a target to jump to. When the program reaches the function ”Jump”, the process will be continued at the programmed label.

There is no automatic return!

Label

This function marks the target of the program jump. A maximum of 100 jump labels can be defined.

2-24

Editing programs 737CE/1.94/01

Editing programs

3.1.1.2 Parallel functions

The SECOM provides a parallel function group for each peripheral equipment, like e.g. addition tanks, preparation tank, dye kitchen tank, etc.

Like the main functions all parallel functions of the same type are combined in function groups.

For each group there is a function group text and an icon.

The standard configuration for a jet for instance provides the following parallel function groups:

Parallel function groups

• Pump

• Material flow

• Addition tank 1

• Addition tank 2

You will find a detailed description of these functions in a separate function list.

During the project work for your machine the required parallel function groups are selected. If necessary, new groups can be added. A maximum of 12 parallel function groups can be programmed.

Assignment of parallel functions

Up to 8 parallel functions can be assigned to each function group.

Only these functions are visible during the programming and the production process.

737CE/1.94/01 Editing programs

2-25

Chapter 2

Picture 4-1: Main menu

4 Creating a program

A program can be created while a batch is running or if the controller is in the stop mode.

To avoid that every operator can invoke the program editor, the SECOM offers the possibility to lock this function with a pass-code.

If the default access is not set at least to level 4 (”Edit”), the operator only gets access to this function by entering the correct pass-code.

After pressing the lock key, the controller opens a window and you must enter the code. A yellow LED indicates that access to the corresponding level has been granted.

Picture 4-2: Program action window

Press key “PROGRAM” (F4) in the main window.

A selection menu appears.

With the cursor keys select line “New”.

A window to enter the program header data will be shown.

2-26

Editing programs 737CE/1.94/01

Editing programs

4.1 Entering the program header

A program header is automatically generated for each new program. Accessible for the operator are the fields for the program number, the program name and the comments.

A number (maximum 4 digits) must be assigned to each program. By default the controller shows the lowest free number (can be changed). This number is the main key for the program administration.

Setting up the program number

Picture 4-3: Program header window

Confirm the number or enter a new one.

Each program can have a name with a maximum of 20 characters. Thus, the operator has the possibility to enter meaningful program names distinguishing similar programs one from another.

After having entered the program number the window for the input of the program name is displayed. Use the cursor keys and/or the numerical keypad to select the required characters, digits and special of the program name.

Entering the program name

Picture 4-4: Program name input window

737CE/1.94/01 Editing programs

2-27

Chapter 2

Entering program comments

Every program can have a comment of up to 60 characters. This gives you the possibility to save important information with each program, like e.g. ”for light color shades only”.

After entering the program name press the OK key to close the character selection window.

If you do not wish to enter comments press F2 or use the cursor keys to select

“SAVE” and press OK.

Enter your comments in the first line as explained under program name above.

Saving the program header

To enter text in the second line you have to close the selection window by pressing the OK key and to move to the second line for comments. Repeat the procedure shown above to enter the second line of text.

After you entered the program name and eventually the comments please press F2 or use the cursor keys followed by the OK key to store the program header information.

At the same time the window for the input of program steps will be shown.

4.2 Entering program steps

The program steps have to be entered in the same sequence they are to be processed later in the program.

Each step has one main function and up to 12 parallel functions (depending on the configuration). Thus, using relatively few steps can create a complete program and it is guaranteed that the parallel processes are running optimized next to the main functions.

2-28

Editing programs 737CE/1.94/01

Editing programs

4.2.1 Programming main functions

For the programming of the main function you have to select the function group first.

Then the desired function is selected.

Picture 4-5:

Program step

Window

Step 2 is marked

”Program start” is inserted automatically as the first program step.

The step marked with the cursor can be programmed after pressing the OK key.

A new window for the selection of the function groups is shown.

Picture 4-6:

Selection of function groups

737CE/1.94/01 Editing programs

2-29

Chapter 2

Selecting main function groups

Press the 0 key and the group selection window for the main functions will be shown.

Each function group has an icon that symbolizes the corresponding group.

Picture 4-7: Example of a main function group window

2-30

During the project work for your machine, 8 main function groups can be selected as a maximum. They may be different depending on the machine type and your special requests.

Examples of main function groups:

• Dyeing

• Filling

• Rinsing

• Draining

• Dosing ADD 1

• Inject ADD

• Operator Call

• System

Select the requested main function by entering the function group number of the requested main function group or use the cursor keys to select it, followed by the OK

key.

In case that a function group contains only one function, the window to enter the parameters will be displayed directly.

Editing programs 737CE/1.94/01

Select the desired function by entering the related number on the keypad (example: temperature control). A window with the function picture and a keypad to enter the parameters will be shown.

Editing programs

Picture 4-8: Example of a function display

Temperature control

For the function ”temperature control” you can enter the following values into the three input fields:

• Upper field ⇒ temperature

Entering function parameters

• Middle field ⇒

• Lower field ⇒ gradient hold time

It might be possible that certain parameter fields contain already some values. If this is the case, then default values have been assigned in the configuration of the controller, representing common settings. The values are automatically inserted if you select a function. This may ease your programming work.

Of course you can overwrite the default value by any other value within specified limits. However, the value entered by you is only valid for the current program step.

When you select the same function in another step you will note that the default values are shown again.

During the project work for your machine the minimum and maximum values of each parameter are set in the configuration. When a parameter is entered that is not within the programmed limits, the input is rejected and the configured minimum or maximum values will be used instead. You can overwrite those values again by entering a value that is within the limits.

Min. and Max. values

The name and the minimum/maximum value of the actual edited parameter will be shown in the upper line of the window.

The selection of the parameters takes place by using the cursor keys.

737CE/1.94/01 Editing programs

2-31

Chapter 2

Selecting main functions

Enter the parameter(s) and press the F2 key to save this function.

In case that you do not wish to enter a value at this stage or if you have selected a wrong function, you can delete the function by using the F1 key.

If a main function group includes more than one function, a selection window with the available functions will be shown first.

Picture 4-9: Function selection window

Main function group

"Operator call"

Select the requested function by pressing the related number on the keypad.

2-32

Editing programs 737CE/1.94/01

Editing programs

4.2.2 Programming parallel functions

Parallel functions are processed parallel to the main functions.

The configuration of the controller contains parallel function groups for the peripheral equipment of the machine, like e.g. preparation tank, addition tank, dye kitchen tank, pump, winch, etc.

Picture 4-10: Select parallel function group

Enter the number of the parallel function (group) you want to select.

In case that a function group contains only one function, the window to enter the parameters will be displayed directly.

Picture 4-11: Enter parallel function parameter

Enter the parameter(s) and press the F2 key to save this parallel function.

In case that you do not wish to enter a parallel function at this stage or if you have selected a wrong function, you can deselect/delete the parallel function by using the

F1 key.

737CE/1.94/01 Editing programs

2-33

Chapter 2

Selection of parallel functions

If a parallel function group includes more than one function, a selection window with the available functions will be shown first.

Picture 4-12:

Example of a function selection window

The requested function can be selected by pressing the related number key or by using the cursor keys, followed by the OK key.

Programming parallel functions only

If you want to program a step with a parallel function only, you must program the function ”No Operation” as a main function first. This function can be found in the main function group ”System“.

Copied parallel functions

After this is done, you can select and program the parallel function(s) as described above.

Some parallel functions like pump and material flow (that are needed in nearly all steps) are marked as “copied functions“ for easier programming.

If these functions are programmed in one step, they will automatically be copied to all following steps. Thus, it is not necessary to program them over and over again.

In case you need other parameter values for these functions from a certain program step onwards, you can change of course the parameters at any time.

4.2.2.1 More than 8 parallel function groups

If more than 8 parallel function groups are available in the configuration for your machine, an arrowhead is shown at the right hand side of the window.

2-34

Editing programs 737CE/1.94/01

Editing programs

4.3 Saving program steps

After the selection and programming of main and parallel functions, the current program step can be saved.

Select with the cursor keys the “SAVE” button and use the OK key to confirm and store the step.

Picture 4-13:

Programmed step

The step is saved in the SECOM intermediate memory and the program step window is shown again. The main function text of the step that has just been saved will be displayed and the next program step will be marked.

All following steps are programmed as described above.

4.4 Saving programs

You can leave the program editor by pressing the Esc key.

The current edited program will automatically be stored in the SECOM.

737CE/1.94/01 Editing programs

2-35

Chapter 2

5 Modifying programs

All existing programs can be modified either if the controller is stopped or while a batch is running.

To avoid that every operator can invoke the program editor, the SECOM offers the possibility to lock this function with a pass-code.

If the standard access is not set at least to level 4 (”Edit”), the operator only gets access to this function by entering the correct pass-code.

After pressing the lock key, the controller opens a window and you must enter the code. A yellow LED indicates that access to the corresponding level has been granted.

Picture 5-1: Program action window

Press key ”PROGRAM” (F4) when in the main menu.

A selection menu is shown.

Select menu item ”Modify” by using the cursor keys and confirm with the OK key.

A window showing all programs stored in the

SECOM will be displayed.

2-36

Editing programs 737CE/1.94/01

5.1 Selecting a program

Editing programs

Picture 5-2: Program selection window

Select the program to be modified by using the cursor keys followed by the OK key.

The program step window of the selected program will be shown.

Picture 5-3: Program window

On the left side of the window the various program steps will be shown (main functions), on the right side you can find 6 fields.

You have to use the cursor keys “left / right” to switch between the step list and the fields. The active field will be shown with red letters and a frame.

With the “up / down” cursor keys the different fields can be selected. Pressing the

OK key start the selected function.

737CE/1.94/01 Editing programs

2-37

Chapter 2

Picture 5-4: Program window

5.2 Changing program names and comments

Picture 5-5: Program name and comment window

Press the F3 key or select the ”NAME” field by using the cursor keys and press OK.

Program name and comments of the program are displayed.

2-38

Select the field to be modified by using the cursor keys..

The character selection window appears.

Enter, change or delete the characters as described above for creating a program.

If you are done, press the F2 key or select the “SAVE” field with the cursor keys and confirm with OK. This stores your modification and the window will be closed.

If you changed the program number then you have created a copy of the program under a new program number.

Editing programs 737CE/1.94/01

5.3 Modifying a program step

Editing programs

Picture 5-6: Program step window

Select the program step to be modified by using the cursor keys.

You now have the possibility to modify or to delete an existing step or to insert a new step at this point of the program.

Press the OK key to confirm the program step selection. The step function window is displayed.

Picture 5-7:

Programmed step

737CE/1.94/01 Editing programs

2-39

Chapter 2

Picture 5-8: Function step window

5.3.1 Modifying the main function parameters

Press the 0 key. The function window will be opened.

You can modify the values if the field is displayed in inverted colors (white text on blue background).

If you are finished with your modification press the F2 key to save the changes.

5.3.2 Exchange/delete main functions

In order to delete or exchange a main function please press the 0 key. The window to enter the function parameters will be shown.

Press the F1 key. The function will be deleted and you get back to the step window. If necessary you can now program a new main function (function exchange).

5.3.3 Edit parallel functions

You can edit the parameters of programmed parallel functions or you can delete functions or insert new ones.

2-40

Editing programs 737CE/1.94/01

Editing programs

5.3.3.1 Change parameters of parallel functions

Enter the number shown underneath the desired function. A window to enter the function parameters will be shown.

Now select the parameter which value you want to change (the selected parameter is shown with a blue background) and enter the new value via the numeric keypad.

In order to save the changes please press the F2 key.

5.3.3.2 Delete parallel functions

First, enter the number shown underneath the desired function. A window to enter the function parameters will be shown.

Please press the F1 key. The function will be deleted and you get back to the step window. If necessary you can now select a new function (function exchange).

Picture 5-9: Function window

5.3.3.3 Program new parallel functions

If no function is programmed on the selected resource (is the case if the parallel function icon is grayed out) then you can program a new parallel function. This is done in the same way as already described in chapter “Programming parallel functions”.

737CE/1.94/01 Editing programs

2-41

Chapter 2

Picture 5-10:

Program step window

Step 5 has been marked

5.4 Inserting a program step

Mark the step in the program step window by using the cursor keys to insert a step above the selected one.

Picture 5-11:

Program step window

An empty step has been inserted on step

5

Press the F1 key or select the ”INSERT” field by using the cursor keys followed by the OK key.

2-42

An empty step is inserted at the marked position and all following steps are moved one step down.

Press the OK key in order to select the function and to program and save the step as described earlier.

You have to use the cursor keys “left / right” to switch between the step list and the fields. The active field will be shown with red letters and a frame.

With the “up / down” cursor keys the different fields can be selected. Pressing the

OK key executes the selected function.

Editing programs 737CE/1.94/01

Editing programs

5.5 Deleting a program step

Mark the program step to be deleted in the program step window by using the cursor keys. Then press the F2 key or select the “DELETE” field with the cursor keys and confirm with the OK key.

Picture 5-12:

Program step window

Step 4 marked for deletion

The marked step will be deleted and all following steps are moved up one step.

Picture 5-13:

Program step window

Step 4 has been deleted

737CE/1.94/01 Editing programs

2-43

Chapter 2

6 Copying a program

When creating a program that is quite similar to an already existing program, you can use the copying function to simplify the programming work. After having copied the program, you can modify the steps and functions that are different.

Moreover, it is possible to copy programs from or to a USB memory stick and to transfer the copied programs to other controllers. If the controller is connected to a host system, it is also possible to copy programs from or to the host. Thus, a program created on one controller can run on other controllers as well (if the machines and the functions are similar!) without the need to write it over and over again.

It is possible to copy programs from the main menu while a batch is running or if the controller is stopped.

To avoid that every operator can invoke the program editor, the SECOM offers the possibility to lock this function with a pass-code.

If the standard access is not set at least to level 4 (”Edit”), the operator only gets access to this function by entering the correct pass-code.

After pressing the lock key, the controller opens a window and you must enter the code. A yellow LED indicates that access to the corresponding level has been granted.

Picture 6-1: Program action window

Press key ”PROGRAM” (F4) when in the main menu.

A selection window is shown.

Select menu item ”Copy” by using the cursor keys followed by the OK key.

A window for the copy will be opened.

2-44

Editing programs 737CE/1.94/01

Editing programs

6.1 Copying a program on the controller

Make sure that all drives for the source and the target program are set to ”Intern”.

Picture 6-2: Program copying window

In order to do this, activate the field ”Drive”, press the OK key and select ”Intern”.

With the help of the cursor keys and the OK key you can activate the different input and key fields. Activate the field for the “Source program” to select the program that will be copied. A list of all available programs in the SECOM will be displayed:

Picture 6-3: Select drive

Picture 6-4: Program selection window

Select the program to be copied by using the cursor keys and OK.

737CE/1.94/01 Editing programs

2-45

Chapter 2

Picture 6-5: Program copy window the target program has been specified

The selected program is shown in the program source field as well as in the destination field.

The controller will automatically assign a new program number (next lowest, unused number) for the target program. By selecting the destination field you can modify the program name and you can also choose a different number if you want to.

Picture 6-6: Program copy window

Copying was successful

Select the ”COPY” field by using the cursor keys followed by the OK key.

The program is copied (with the new name) to the new program number on the internal flash disk.

Every time you copy a program, a message will be shown. The displayed text either indicates that the copy process has been successful or that an error occurred.

2-46

Editing programs 737CE/1.94/01

Editing programs

6.2 Copy to an external drive

In order to create backups of programs or to exchange dye programs between controllers that have the same function configuration, programs can be written and read to/from external media.

6.2.1 Copy via USB (USB memory sticks)

Dye programs from controllers can be stored on USB memory sticks and can be read back from there. For this the memory stick needs to be connected to the USB port of the controller.

For the copy process the source or destination drive must be set to USB instead of

intern.

Picture 6-7:

Program copywindow

“USB“ has been selected

Please note that it will take some time until the external USB memory stick is recognized and the controller can start the copy process.

737CE/1.94/01 Editing programs

2-47

Chapter 2

Picture 6-8: Drive not ready

If the “COPY” field is selected too early, the following message will be shown.

Picture 6-9: Select drives, drive not recognized!

Press the OK key and check the color of the USB selection. As long as it is shown in red color, the stick is not recognized and it will change to black if it is. Then you can try to start the copy process again.

2-48

Other reason for drive not ready could be that the USB stick is not formatted, defective or not (correctly) inserted.

Editing programs 737CE/1.94/01

Editing programs

6.2.2 Copy via the network (host operation)

Under network operation the controller can store and read dye programs from/to a network drive. All controllers of a certain machine group (machines with the same function configuration) will access the same network directory which allows exchanging programs directly via the network.

For the copy process the source or destination drive must be set to Host instead of

intern

.

6.3 Copying all programs (backup)

This function allows copying all available programs without the need to selecting them.

This functionality is mainly used to create a backup of the dye programs on a memory stick or to exchange complete sets of programs between controllers.

Press key “Program” (F4) in the main menu.

A selection window will be shown.

Select menu item “Copy“ by using the cursor keys and the OK key.

Picture 6-10:

Program action window

A window for the copy operation will be shown.

Picture 6-11:

Program copy window

Please use the cursor “right” key.

737CE/1.94/01 Editing programs

2-49

Chapter 2

Picture 6-12: Select drives

The next window will be opened where you can select the source and destination drive. As an example we will copy all internally stored programs to the USB stick.

Picture 6-13: Error message "No USB stick"

To start the copy process. press the F2 key or select the “COPY” field with the help of the cursor keys and the OK key.

6.4 Copy messages

The following errors may occur:

There is not enough space on the flash disk to save another program.

The USB stick has been selected as drive but has not been inserted. You will find

more information on the USB stick in chapter 1, item 2 Operation, on page 1-3.

A host as drive has been selected but there is no connection to a fileserver.

2-50

Editing programs 737CE/1.94/01

Editing programs

7 Deleting a program

You can delete a program from the main menu either if the controller is stopped or while a batch is running.

To avoid that every operator can invoke the program editor, the SECOM offers the possibility to lock this function with a pass-code.

If the standard access is not set at least to level 4 (”Edit”), the operator only gets access to this function by entering the correct pass-code.

After pressing the lock key, the controller opens a window and you must enter the code. A yellow LED indicates that access to the corresponding level has been granted.

Press key “PROGRAM” (F4) in the main menu. A selection window will be shown.

Select menu item “Delete“ by using the cursor keys and press OK.

Picture 7-1: Program action window

A list of all programs in the SECOM is displayed.

Picture 7-2: Program selection window

737CE/1.94/01 Editing programs

2-51

Chapter 2

Picture 7-3:

Confirmation window

Select the program you want to delete by using the cursor keys followed by OK.

Before the program is actually deleted, a confirmation window will be shown.

Press the ESC key to cancel the deleting process.

Press the OK key to delete the selected program.

2-52

Editing programs 737CE/1.94/01

Editing programs

8 Addition treatment

The daily work in a dye house often requires using addition treatments while a batch is running.

When writing new dyeing programs, addition treatments that might become necessary during the dye process, can already be implemented.

When a program is running and the function ”Operator call Sample” is active, it is possible to select addition treatments. Only the additions that have been set up with the program are displayed. Additionally, reasons for addition treatments can be selected and assigned.

From ”Sample” to ”Addition” and back

When the addition is finished, the SECOM automatically jumps back to the function

”Operator call sample” where it came from.

The advantages of this kind of additional treatment are obvious:

• All different additional treatments are processed in the same way

• The number of additions and the run time thereof can clearly be registered

• Reasons for additions can be registered and analyzed

Advantages

8.1 Marking the additions

In order for the SECOM to recognize additions the system function ”Addition Start” has to be programmed as the first step and the function ”Addition End” has to be programmed as the last step of the addition treatment.

Defining additions

You may enter an addition name for each system function ”addition start” to clearly specify all different additions.

It is possible to edit up to 100 different addition texts, like e. g:

• SUBST. 98°C 15 MIN

• DISP. 130°C 20 MIN

• REACTIVE 50°C 30 MIN

• ADDING SALT 15 MIN

• ADDING ACID 10 MIN

Addition texts

737CE/1.94/01 Editing programs

2-53

Chapter 2

Picture 8-1: Program step window

Edit addition treatment

8.2 Program structure of addition treatments

Basic rules to be observed:

• All addition treatment steps have to be programmed after the system function

”Program End“.

• Every addition treatment has to start with the system function ”Addition Start” and has to end with system function ”Addition End”.

• Several additions can be programmed one after another.

8.3 Creating an addition treatment

You can create an addition treatment while writing a program or by modifying an existing program.

After the function ”Program End” in the program step window, the system function

“Addition Start” has to be programmed.

2-54

Editing programs 737CE/1.94/01

Editing programs

Picture 8-2:

“Addition Start” window

If the “Addition Start” function is selected, press OK to open the list with the addition texts.

A list with all existing addition texts is shown.

Picture 8-3: Addition text window

Select the matching addition name by using the cursor keys.

Press the OK key.

You will find a description on how to modify addition texts and how to set up new

addition texts under 8.4 Defining addition texts, on page 2-56.

The step can now be completed with eventually necessary parallel function and then be saved.

After that, the next steps of the addition treatment can be programmed as well.

The system function ”Addition End” has to be programmed as the last step of the addition treatment.

737CE/1.94/01 Editing programs

2-55

Chapter 2

If more addition treatments are required, they have to be programmed directly after the system function ”Addition End”.

Possible errors:

In case you forgot to program ”Addition End”, the controller advances to the next program step (if available) instead of jumping back to the ”Sample” step!

If there is no more step available, the controller changes the status to ”END”, the batch is finished and cannot be started again!

Picture 8-4: Addition text window

Addition text has been edited

8.4 Defining addition texts

In case that further addition texts are needed or if it is necessary to modify an existing text, you have to open the program editor.

You get to the addition text window if you edit an existing step where the system function “Addition start” is programmed. If the “Addition Start” function is selected, press OK to open the list with the addition texts. A window with a list of all existing addition texts will be opened.

Select the text to be modified by using the cursor keys. Then press the F1 key or select the “Modify” field by using the cursor keys followed by OK.

The addition texts are edited with the help of the keyboard window. Enter the required

characters as described earlier in item 4.1 Entering the program header, on page 2-27

2-56

Select with the cursor keys the “OK” field and press the OK key to save the modified text.

Editing programs 737CE/1.94/01

9 Variable function parameter

When making up the machine configuration, formulas can be created that use certain batch data in order to calculate specific function parameter values. These parameters then become variable ones. During programming a function for which a formula exists, the operator has the choice to either enter a fixed value or to choose the result from the formula as function parameter (e.g. filling quantity).

With these variable function parameters it is possible to adapt and to optimize standard programs for different batch weights, different materials and shades.

When starting a batch, the required parameters, like batch weight and liquor ratio are entered. When the controller comes to a function that uses the related formula (filling with counter for instance), the batch parameters are processed and the filling value as a result (in this case) is automatically calculated and used as parameter value rather than a fixed value.

9.1 Definition of variable function parameters / formulas

Variable function parameters have formulas assigned in the machine configuration.

These formulas may include the following components:

• Batch parameters

• Set values (function parameters)

• Actual values

• Timer values

• Machine constants

• Numerical constants

All values can be combined with each other. Due to this, numerous variations of formulas are possible, from a very simple assignment up to a complex calculation.

You will find a description of the programmed formulas in your machine configuration in your supplier’s documentation.

Editing programs

737CE/1.94/01 Editing programs

2-57

Chapter 2

Picture 9-1: Edit variable function parameters

9.2 Editing variable function parameters

When editing a function and an input field for a variable function parameter is reached, the field “FORMULA” is displayed in the program function key line.

Press the F3 key or select the ”FORMULA” field with the cursor keys and the OK key to choose the input for this parameter.

Picture 9-2: Formula list

The formula(s) available for this parameter are displayed.

Select the required formula by using the cursor and the OK key.

Press the F2 key or select the “STORE” field to save the step.

The following entry will be shown in the parameter field after having selected a formula:

F{0}

2-58

Editing programs 737CE/1.94/01

Editing programs

Picture 9-3:

A formula has been selected

If a set value is included in the formula, then in addition to select a formula you have to enter the set value into the parameter field.

Picture 9-4:

A set value has been entered

The following entry will be shown in the parameter field when a formula has been selected and a set value has been entered:

F{xxx}

xxx = set value entered

If this concludes programming this step, press the OK key.

737CE/1.94/01 Editing programs

2-59

Chapter 2

2-60

Editing programs 737CE/1.94/01

Operation

Chapter 3

10 STARTING A BATCH ................................................................. 3-63

10.1

G

ENERAL

I

NFORMATION

........................................................... 3-63

10.2

O

PENING THE BATCH CREATION WINDOW

................................... 3-64

10.3

P

ROGRAM SELECTION

.............................................................. 3-65

10.3.1

Selection list .................................................................... 3-65

10.3.2

Entering the program number ......................................... 3-66

10.4

E

DITING BATCH INFORMATION

................................................... 3-67

10.4.1

Entering batch texts ........................................................ 3-67

10.4.2

Entering batch parameters .............................................. 3-68

10.5

B

ATCH PROGRAM GENERATION

................................................. 3-69

10.6

S

TARTING THE PROGRAM

......................................................... 3-70

10.6.1

Possible errors when starting the program ..................... 3-70

10.7

B

ATCH LIST

............................................................................. 3-71

10.7.1

Loading an OrgaTEX batch ............................................ 3-73

11 THE PROGRAM IS RUNNING .................................................... 3-74

11.1

D

ISPLAY STATUS LINE

.............................................................. 3-74

11.2

D

ISPLAY OF FUNCTIONS

........................................................... 3-74

11.2.1

Display of actual values .................................................. 3-74

11.2.2

Main functions ................................................................. 3-75

11.2.3

Parallel functions ............................................................ 3-75

11.2.3.1

Display of parallel function parameters .............................. 3-76

11.3

M

ANUAL

I

NTERVENTION

........................................................... 3-77

11.3.1

Manual intervention by pressing the hot key ................... 3-77

11.3.1.1

Changing the actual main function and its parameters ...... 3-78

11.3.1.2

Changing the parallel functions and their parameters ........ 3-78

11.3.1.3

Return to the automatic mode ........................................... 3-79

11.3.1.4

Changing the program steps ............................................. 3-79

11.3.2

Some explanations ......................................................... 3-80

11.4

D

ISPLAY OF OPERATOR CALLS

.................................................. 3-81

11.4.1

Operator call “Sample” .................................................... 3-81

11.4.1.1

Sample is O.K. .................................................................. 3-81

11.4.1.2

An addition is required ....................................................... 3-82

11.4.1.3

Possible errors .................................................................. 3-83

737CE/1.94/01 Operation

3-61

Chapter 3

11.4.1.4

Select a certain step for an addition ................................... 3-84

11.5

P

ROGRAM END

........................................................................ 3-84

12 INTERRUPTING A PROGRAM .................................................. 3-85

12.1

P

RESSING THE STOP BUTTON

................................................... 3-85

12.2

S

TOP

-

ALARM

.......................................................................... 3-85

12.3

P

OWER FAILURE

...................................................................... 3-86

12.4

R

ESTARTING THE PROGRAM

..................................................... 3-86

13 MANUAL OPERATION MODE ................................................... 3-88

13.1

C

ONDITIONS

........................................................................... 3-88

13.2

H

OW TO ACTIVATE THE MANUAL OPERATION MODE

? ................... 3-88

13.3

H

OW TO LEAVE THE MANUAL OPERATION MODE

? ........................ 3-89

3-62

Operation 737CE/1.94/01

Operation

10 Starting a batch

10.1 General Information

To collect batch data it is necessary to start batches. First of all, a batch has to be created and a program has to be assigned to every batch. Depending on your machine configuration it is possible to enter additional information for every batch like batch texts and batch parameters. After all entries have been made using the “Start” key can start a batch.

Picture 10-1:

Example: Creating a batch with batch texts and parameters

Batch texts are entered as alphanumeric values and are stored as batch info. They will help to assign a certain batch to a customer or order. You will find more information on

batch texts in item 10.4.1 Entering batch texts, on page 3-67 in this chapter.

Batch parameters are entered as numeric values, which are used for the calculation of variable function parameters. Using these parameters make the programs more universal and the filling quantity can be calculated in accordance with the batch weight and the liquor ratio. You will find more information on the batch parameters in item

10.4.2 Entering batch parameters, on page 3-68 in this chapter.

The SECOM provides a maximum of 20 input fields for the input of batch texts, like customer name, order number etc. and a maximum of 20 input fields for the input of batch parameters like batch weight, fabric length or liquor ratio etc. Please note that the number of texts and parameters (if any) depends on the particular configuration and may vary from configuration to configuration.

In case that your machine configuration includes formulas (see chapter 2 / 9 Variable function parameter), these parameters are assigned when starting the batch.

Depending on the configuration the calculation of the formulas takes place either at batch creation time or when the particular function is activated.

737CE/1.94/01 Operation

3-63

Chapter 3

Picture 10-2:

Program action window

10.2 Opening the batch creation window

If the controller is in the stop mode press the F4 function key. A menu is shown.

Please use the cursor and the OK key to select the “Batch” menu item.

Depending on the configured program access level, the batch creation window will be opened immediately or after entering the appropriate pass-code.

Picture 10-3: Batch creation window

The creation of a new batch first assigns a new reference number on the SECOM that allows for a definite assignment of actual and historical data for this batch.

3-64

Select the desired dye program.

Operation 737CE/1.94/01

Operation

10.3 Program selection

There are two possibilities to select programs:

1. Select programs from a list of all existing programs in the SECOM.

2. Enter the program number.

10.3.1 Selection list

From the batch start creation window press the OK key.

Picture 10-4: Batch creation window

A window with all available programs on the SECOM will be shown.

Picture 10-5:

Program selection list

737CE/1.94/01 Operation

3-65

Chapter 3

Use the cursor keys and OK to select the required program.

The batch creation window is displayed again.

The program name and the program number of the selected program are shown.

Make sure that the selected program (name and program number) is the correct one and enter additional batch data. After this is done please press the OK key to confirm the selection and entries.

If a wrong program has been selected you can use the OK key again to correct your selection.

10.3.2 Entering the program number

Select the program number field by using the cursor keys and press OK. Then enter the desired program number. The controller will select the desired program.

If a program number has been entered that does not exist on the SECOM the controller will open the list of all programs, positioned on the closest match to the entered number.

3-66

Operation 737CE/1.94/01

Operation

10.4 Editing batch information

Depending on the machine configuration it will be possible to enter batch texts and batch parameters.

Picture 10-6: Input of batch texts and parameters

Activate the field you want to edit with the cursor keys, followed by the OK key, and depending on the kind of field (alphanumeric or numerical) the keyboard or the numerical keypad will be shown.

10.4.1 Entering batch texts

For the input of batch texts an alphanumerical keypad will be displayed. The maximum number of characters will be shown. Enter the required characters as described earlier

in item 4.1 Entering the program header, on page 2-27. Select with the cursor keys the

“OK” field and press the OK key to store the text.

.

Picture 10-7:

Input of batch texts

737CE/1.94/01 Operation

3-67

Chapter 3

Picture 10-8: Input of batch parameters

10.4.2 Entering batch parameters

Depending on the machine configuration it is possible to enter up to 20 batch parameters for every batch. A numerical keypad will be shown and can be used for input.

If the entered values are not within the tolerances specified in the machine configuration, the controller automatically uses the minimum or the maximum value respectively. Either use these values or overwrite it with a correct one.

By pressing the OK key the entered value will be stored.

3-68

Operation 737CE/1.94/01

Operation

10.5 Batch program generation

After finishing the input of all batch information data and after pressing the OK key, a window showing the generation of the batch program will be shown.

Picture 10-9:

Information window during batch generation

If the program has been created on the SECOM, the main window is displayed.

Picture 10-10: Main menu before program start

The program number and the number of the actual step (step 1 at this point) are shown in the status line.

The batch status is set to ”READY”. This means that a batch/program has been selected but has not been started yet.

On the left side of the window the function symbol of the first program step (start function) is shown. The right side of the window shows the program name.

The window of the step list shows the steps of the actual selected program.

737CE/1.94/01 Operation

3-69

Chapter 3

Picture 10-11:

Program start not possible, PLC offline

10.6 Starting the program

Press the green Start button on the SECOM to start the program.

The batch status is set on ”RUN” and the green LED in the start button is lit.

The program start function is processed and the program automatically advances to the next program step. All following programmed functions are processed in sequence.

10.6.1 Possible errors when starting the program

Under certain error conditions (e. g. PLC is offline or a stop alarm is active) it is not possible to start a program.

Information about alarm No 301 “PLC Offline“ can be found in chapter 5, item 15.3.3

System alarms of the SECOM, on page 5-112.

Picture 10-12:

Program start not possible, stop alarm is active

The alarm number is displayed in the status line of the SECOM. You will find a complete list of all SECOM and PLC system alarms in chapter 5. First eliminate the problem and then quit the alarm message.

As soon as there is no stop alarm active anymore the program can be started by pressing the start button again.

3-70

Operation 737CE/1.94/01

Operation

10.7 Batch list

With the help of the batch list you have the possibility to schedule batches on the controller or to download batches from the central control system OrgaTEX. If the option “Batch list” is enabled please press the F4 key, a selection window will be shown.

Picture 10-13:

Program action window

Select the menu item “Batch list”.

A window with the list of all available batches on the controller will be shown.

Picture 10-14: Batch selection window

The actually active or selected batch will be shown marked by a green rectangle. In order to select or start another batch please select the corresponding line first by using the cursor keys. Then press the OK key or the F4 key to select the batch.

The window will be closed, the batch program will be created and the controller changes to the state “READY”. The batch can now be started by pressing the green start button.

737CE/1.94/01 Operation

3-71

Chapter 3

Picture 10-15:

Selection window

To get additional information about the selected batch please press the F2 function

key. A selection window will be shown.

Picture 10-16: Batch information

Select the menu item “Batch Info”. A window with additional batch information will be shown:

3-72

The window will be closed by pressing the Esc key. You get back to the batch selection window.

Via the selection menu additional tasks can be selected like deleting a batch or creating a new one.

The batch list is only available if the value for the system constant 6 is set to 2.

Operation 737CE/1.94/01

Operation

10.7.1 Loading an OrgaTEX batch

If the controller is connected to the OrgaTEX host system then it is possible via the batch list to select and load batches that were created and queued in OrgaTEX to the controller.

If the batch list is shown, please press the F1 key. The batch list with the scheduled batches for this machine which are enabled for download will be shown.

Picture 10-17:

OrgaTEX batch list

Mark the desired batch by using the cursor keys. By pressing F4 or the OK key the batch will be selected and transferred from the host system to the controller. The controller shows the status “READY” and the batch can be stated by pressing the green start key.

If the desired batch cannot be found in the host batch list you can switch back to the local batch list by pressing the F1 key.

737CE/1.94/01 Operation

3-73

Chapter 3

11 The program is running

While a program is running, the operator gets information on the current status of the process at any time.

11.1 Display status line

During a running program, the left side of the status line shows two symbols with the actual values of the process.

Picture 11-1: Status line

Normally the status line shows the actual temperature of the dyeing machine and eventually the remaining time in minutes.

What the time value represents depends on the actual running main function. It may represent hold times, delay times or operator call times, etc.

Depending on the main function of the current step it is also possible to display other symbols or actual values. However, this has to be configured by the machine supplier during the projecting works for your machine.

11.2 Display of functions

While a program is running, all active functions are displayed on the screen.

11.2.1 Display of actual values

Picture 11-2:

Display of set values

Next to the function picture, the programmed set values of each function parameter are displayed. The set values are displayed with blue characters on gray ground.

If the controller is running and the function is active, the actual values are also displayed.

Picture 11-3:

Display of actual values

The actual values are displayed with green characters on yellow ground.

3-74

Operation 737CE/1.94/01

Operation

11.2.2 Main functions

The programmed main function of the current program step is displayed on the left side of the window. The information includes the function text, the function picture and the parameters (if any).

Picture 11-4:

Program running

If a function parameter includes a formula, F= is displayed in front of the calculated set value.

See chapter 2 / 9 Variable function parameter.

11.2.3 Parallel functions

The active parallel functions, their function icon and their function name are displayed on the right side of the window. Depending on the machine configuration an additional set parameter value might be displayed with white characters on blue ground. The parallel function group number is displayed below this value.

Parallel functions, which have already been finished or are inactive, are displayed in light color.

Example: Function: Preparation of a tank in the dye kitchen

The function is shown as active until the preparation of the tank has been confirmed.

When the function is confirmed, the symbol and the function name are displayed in light color until the contents of the tank is transferred to the machine in a later step. If this takes place, the tank function

”Preparation” is deleted.

This provides clear information on the current status of the function ”Preparation” and the situation around the tank.

737CE/1.94/01 Operation

3-75

Chapter 3

Picture 11-5:

Displaying parameters and actual values of parallel functions

11.2.3.1 Display of parallel function parameters

You can get information on the programmed parameters of parallel functions at any time while a program is running.

Press the related function number key.

The function text, the function picture and the corresponding set and actual parameters (if the controller is on RUN) are displayed.

In the line underneath the icon the function set time and the actual function runtime will be shown.

Press the Esc key to close this window.

3-76

Operation 737CE/1.94/01

Operation

11.3 Manual Intervention

It is possible to modify the current program step as well as following steps of the running program with the help of the manual intervention function build into the

SECOM.

The following modifications can be made:

All parameters can be changed

Functions can be deleted

Functions can be inserted

Functions can be replaced

In order to prevent that every operator is able to modify the running program with the help of the manual intervention function of the SECOM, it is possible to lock the access to the manual intervention by a pass-code.

There are three different ways to make a manual intervention and they are listed below

11.3.1 Manual intervention by pressing the hot key

While the controller is in ”RUN” mode, press the “Manual Intervention” hot key. The yellow LED in the button starts blinking and the status changes to “Intervent”.

Depending on the access level, the manual intervention editor can be started directly from the program menu window or after entering the appropriate pass-code.

A window will be shown where you can choose to modify main or parallel functions and their parameters or to insert, delete or exchange programs steps within the remaining steps.

Picture 11-6: Manual intervention window

737CE/1.94/01 Operation

3-77

Chapter 3

Picture 11-7:

Function intervention window

11.3.1.1 Changing the actual main function and its parameters

In order to modify the actual main function, please press the 0 key. For the main function the following window appears.

Picture 11-8: Parallel function intervention window

Here you can modify the function parameters by entering different numerical values and/or by selecting different text parameters. Press the F2 key to save the changes.

You can also delete (finish) the function by using the F1 key. This will end the main function and after returning to automatic mode will cause the controller to go to the next (main) step.

11.3.1.2 Changing the parallel functions and their parameters

In order to modify the parallel functions, please enter the number that is shown underneath the function icon. A window as shown below appears.

3-78

Also here, you can change the parameters and store the changes or you can delete

(finish) the parallel function by using the F1 key.

Operation 737CE/1.94/01

Operation

11.3.1.3 Return to the automatic mode

After all the necessary changes have been made and after pressing the F1 key or F2

key you will return to the manual intervention window. If you use the Esc key the controller takes over the new values and/or the finished functions and resumes the automatic operation.

The controller returns to RUN mode and the yellow LED is switched on.

During manual intervention on the SECOM the yellow LED in the intervention hot key is flashing. The controller cannot advance to the next step. The actual functions of the current step are processed normally.

11.3.1.4 Changing the program steps

Via the manual intervention editor changes can be made to the active program step as well as to the following steps.

By selecting the “List” field or pressing the F4 key as shown in the Picture 11-6 a

window showing all the steps of the program will be opened. The next upcoming step is marked. From there onwards all the steps and their function can be changed. It is also possible by selecting the fields “INSERT” and “DELETE” to insert new, empty steps that need to be filled with functions later or to delete complete steps with all its functions. Select the program step you want to change and do the modification as

shown in chapter 2, item 5.3 Modifying a program step, on page 2 -39

Picture 11-9:

Changing program steps

If you are finished, please select the “SAVE” field by using the cursor and press the

OK key, the controller stores all the changes and returns to the main window, changing the status from “Intervent” to “Run” and continues by processing the modified program.

737CE/1.94/01 Operation

3-79

Chapter 3

11.3.2 Some explanations

All modifications are immediately executed while the controller is in the manual intervention mode. However, the controller will not advance to the next program step.

Please note that the manual interventions as described above, be it changing the actual active functions or be it adding, deleting and changing steps will in no way change the original program as stored in the controller memory or on the OrgaTEX host system.

All the changes will be effective on the batch program only. Will say that a copy of the original program that has been assigned to the batch during batch creation will be used. This program with all its eventual changes is valid until program/batch end. If logging is switched on, the actual program (including changes) will be stored together with the other logging and batch data for later reference.

Another batch, using the same program will start with the original version. So if the changes have to be permanent, then the original dye program must be modified.

3-80

Operation 737CE/1.94/01

Operation

11.4 Display of operator calls

When a program is processed and the controller comes to an operator call function, the window ”confirm operator call, please” is displayed.

Picture 11-10:

Message ”Confirm operator call”

The message must be confirmed either by pressing the OK key or the operator call

key. As long as the operator call is active, the yellow LED in the operator call key is flashing.

When the operator call has been finished please use the function key (F3) and the controller advances to the next program step. If the system constant 47 has been set to 1, it is also possible to go to the next step by pressing the operator call key (hot key). You will find more information on the system constants in the SECOM Service

Manual.

11.4.1 Operator call “Sample”

The operator call ”SAMPLE” allows either continuing the dye program or to select and start an already programmed addition treatment.

As long as the function ”Sample” is active, the operator call LED and the addition LED are flashing.

After an eventually necessary addition treatment, the controller returns automatically to the “Sample” step it came from.

11.4.1.1 Sample is O.K.

Press the function key (F3). A selection window is shown.

Select the line ”Go to next step” from the menu, confirm with the OK key.

The SECOM advances to the next program step and continues to process the program.

It is also possible to press key operator call (only if system constant 47 is set on 1).

The controller continues with the next step.

Picture 11-11: "next step" has been selected

737CE/1.94/01 Operation

3-81

Chapter 3

11.4.1.2 An addition is required

Picture 11-12:

"addition" has been selected

Press the function key (F3). A selection window is shown.

Select the line ”Select addition” from the menu, press OK to confirm.

Another window is shown.

As a shortcut it is also possible to press the addition key (hot key) instead of F3. (only

if the system constant 28 is set to “0”). The window shown in Picture 11-13 will then be

displayed directly.

All programmed addition treatments are displayed.

Picture 11-13:

Selection window for programmed additions

Automatic program return

Select the requested addition treatment by using the cursor keys and OK.

The controller jumps to the selected addition treatment and starts it. The yellow LED in the addition key is illuminated as long as the addition is active.

After the addition treatment has been finished, the controller automatically returns to program step ”Sample” it came from.

If no addition treatment program has been programmed the addition selection window will be empty and can be closed by using the Esc key.

3-82

Operation 737CE/1.94/01

Operation

11.4.1.3 Possible errors

If an addition is started directly and not from the program step ”SAMPLE”, the controller cannot return to ”SAMPLE” after the addition treatment has been finished!

The controller stops the program and the alarm 327 ”wrong label address” is displayed.

Solution: Confirm the alarm message. You will find information on how to display the alarm list and how to quit alarms in chapter 4, item 14.2

Alarm list, on page 4-93

Use the cursor keys to move to the corresponding program step

”Sample” and press the green start button.

If the function ”Addition end” has not been programmed the controller advances to the next program step (if available)!

After the last program step has been processed, the program status is set to END!

This means that the program for the current batch cannot be started again!

Solution: Correct the program immediately!

First of all check up to which point the program has been processed!

If the program status has already been set to END, you have to

restart a new batch with the corrected program. Press the cursor keys to move to the corresponding program step ”Sample” and press the green start button.

737CE/1.94/01 Operation

3-83

Chapter 3

11.4.1.4 Select a certain step for an addition

From the operator call “Sample” you can also go to any other step. The program is then processed from that step onwards. Asynchronous functions that were active at the time of sample continue to be processed.

To go to a certain program step press the function key (F3). A selection window is shown.

Picture 11-14: "Step selection" has been choosen

Select the menu item “Select Step”, press the OK key.

A window with the actual dye program is shown.

Picture 11-15:

Program list for the step selection

3-84

Select the desired step by using the cursor keys and confirm with OK. The controller continues the dye program on the selected step.

Such a correction of dye process is not treated or logged as an addition. The dye program will be continued from the selected step onwards. There is no jump back to any sample step. If the program reaches the program end function, the batch will be ended and cannot be started again.

11.5 Program end

As soon as the system function ”Program End” is reached, the program status changes to ”END”.

The SECOM and all active functions are stopped.

The green LED in the start button is off.

The program for this batch cannot be started again.

Operation 737CE/1.94/01

Operation

12 Interrupting a program

The running program can be interrupted due to the following reasons:

• The red stop button on SECOM has been pressed

• A stop alarm occurs

• Power failure

12.1 Pressing the stop button

Pressing the red stop button causes the program running on the SECOM to be stopped.

The program status changes to ”BREAK” and all active functions are interrupted.

If necessary, you may press the cursor keys to advance to another program step.

After that you can restart the program by pressing the green start button.

Parallel functions that were active and not dependent on a step before the stop

button was pressed will continue to run after the controller is restarted.

Hint: If you wish to switch off these parallel functions, move to the step “Program

Start” and start the program from there. All active functions are reset.

Then press the Stop button immediately and move on to the desired program step. Continue the program by pressing the start button.

The start characteristics of asynchronous parallel functions can be influenced by the system constant No. 14 “Mode of asynchronous functions”. Further information about system constants can be found in the Service Manual of the SECOM.

12.2 Stop-alarm

Due to failures in the process, alarms may occur which will stop the program.

The program status changes to ”BREAK” and all active functions are stopped.

An alarm number is displayed in the status line. At the same time an alarm window displays an alarm message.

First of all, you have to quit the alarm message. Then you have to analyze the reason of the failure and to remove the problem.

If this is done press the green start button to start the program again.

737CE/1.94/01 Operation

3-85

Chapter 3

Picture 12-1:

Inquiry: "resume program?”

12.3 Power failure

If a power failure occurs, the SECOM is switched off and all active functions are stopped.

After the power is restored, the controller boots again and the machine configuration is loaded. After the startup screen the main window will be shown. The program step that was active at the time of power loss, will automatically be displayed. The program status indicates ”BREAK”.

Press the green start button to restart the program.

12.4 Restarting the program

To restart an interrupted program press the green start button.

If you restart the program on the same step it was interrupted at, a window with the following text is shown: ”resume program?”

There are two possibilities:

1. Press the OK key (=yes) to continue the program. All functions that were active when the program was interrupted are continued with the current actual values.

Example: A program step with a hold time of 30 minutes has been interrupted after 20 minutes runtime. After pressing the OK key the remaining 10 minutes are running down.

The programmed filling volume of the preparation tank is 150 liters. At the time of interruption 100 liters have already been filled. After pressing the OK key, the remaining quantity of 50 liters will be filled.

2. Press the Esc key (=no) to continue the program with the current program step and the programmed set values.

Example: A hold time of 10 minutes had been programmed. At the point of interruption 4 minutes have been elapsed. After pressing the ESC key, the complete hold time of 10 minutes is running down again.

An asynchronous parallel function in this case will also be restarted. This can lead to the situation that such a function is processed several times. The start characteristics of asynchronous parallel functions can be influenced by the system constant No. 14 “Mode of asynchronous functions”. Further information about system constants can be found in the SECOM Service Manual.

3-86

Operation 737CE/1.94/01

Operation

Each program interruption is an exceptional situation!

The measures to be taken to continue the current process in an appropriate way depend on the failure that led to the program interruption!

Only authorized and qualified personnel only will be in a position to check the current situation and to take the necessary decision and action!

The SECOM can only provide useful information in order to resume the interrupted process!

737CE/1.94/01 Operation

3-87

Chapter 3

13 Manual operation mode

With the manual operation mode the user has the option to start certain functions without having to start a program or a batch.

13.1 Conditions

The manual operation mode can only be activated under the following conditions.

1. Functions must be enabled for manual operation in the configuration.

2. The system constant No. 49 must be set to 1.

3. The controller must be in the stop mode (message “SELECT” or ”BREAK” in the status line).

Picture 13-1:

Display in the status line during manual operation

13.2 How to activate the manual operation mode?

To activate the manual operation mode, press the manual operation key in the stop mode.

The yellow LED in the key is lit as long as the manual operation mode is active. In the status line ”MANUAL” is displayed as controller mode. As current program step and program 0 is displayed.

At the same time the selection window for the function groups that are enabled for manual operation is displayed.

Picture 13-2:

Selection window for function groups

3-88

In order to select a main function group please select the 0 key first and then enter the related number of the desired function group to finally select the function you wish to run. You may also select parallel functions to the main functions by selecting the empty parallel function window and by selecting the desired function(s).

Operation 737CE/1.94/01

Operation

If you wish to execute parallel functions only (parallel track) then you can simply select a parallel function. There is no need to program an additional main function (No operation) in the manual operation mode. You will find more information on how to

select functions in chapter 2, item 4.2.1 Programming main functions, on page 2-29.

After the required functions are selected and the function parameters are inserted, the manual operation for this function can be initiated by pressing the green start button.

”MANUAL RUN” is displayed in the status line.

While the manual operation mode is active, the functions are processed normally until the PLC program quits them. The functions that have been quit are displayed in light color.

Picture 13-3:

Display while manual operation mode is active and controller is started

Picture 13-4:

Display of the finished functions while the manual operation mode is active

After the controller has been started, the actual parameter values are shown next to the set parameters.

As it is not possible to run a program in the manual operation mode but single functions only, there is no function ”program end” for this mode. For this reason, the controller mode does not automatically change to stop when the functions are finished. The controller has to be stopped manually by pressing the red stop button.

13.3 How to leave the manual operation mode?

The manual operation mode can only be left in the stop mode. To stop the controller, press the red stop button. When the controller is in the stop mode, you can quit the manual operation mode by pressing the manual operation key.

While the controller is in the manual operation mode, the controller can be started although a stop alarm is active.

If a stop alarm occurs after the controller has been started, it will be stopped.

737CE/1.94/01 Operation

3-89

Chapter 3

3-90

Operation 737CE/1.94/01

Batch information

14 INFO-MENU ................................................................................ 4-92

14.1

P

ROCESS INFORMATION

........................................................... 4-92

14.2

A

LARM LIST

............................................................................. 4-93

14.3

E

VENT LIST

............................................................................. 4-95

14.4

H

ISTORY

................................................................................ 4-96

14.4.1

Batch selection ............................................................... 4-97

14.4.2

Display of process values ............................................... 4-97

14.4.3

Copy historical batch data ............................................. 4-100

14.4.3.1

Only one batch ................................................................ 4-100

14.4.3.2

All batches ....................................................................... 4-101

14.5

P

ROGRAM LIST

...................................................................... 4-102

14.6

B

ATCH INFO

.......................................................................... 4-104

Chapter 4

737CE/1.94/01 Batch information

4-91

Chapter 4

Picture 14-1:

Info menu while a program is running

14 Info-menu

Starting from the main window you can get information on the machine, the process and the current program at any time.

Press the F2 key from the main window. An Info menu will be shown.

14.1 Process information

For the process information of the machine or of related equipment, like the color kitchen etc. pictures with the actual values of the running batch can be displayed (if configured accordingly).

Use the cursor keys and OK for the selection of the menu item ”Process Info”.

Picture 14-2: Process info: Overview

Display of the current actual values

The first window of the process information, normally a machine diagram, will be shown.

4-92

Different analog values (temperature, speed, filling volumes, etc.) and time values can be configured during the project work for your machine according to the specific machine and the sensors available.

Batch information 737CE/1.94/01

Different fields are available for each picture graphic to display the actual values

(actual values, set values, batch texts, batch parameters and time values with their related units). The actual values are constantly updated.

Press the Esc key to close this window and to return to the main menu.

If more than one process picture has been configured there will be action fields in the graphics that allow changing to the other picture(s) via the cursor keys and the

function keys. In the example above there is an action field (clock symbol) in the upper left corner.

Batch information

14.2 Alarm list

If you want to display active alarms you have to press the F2 key to open the info menu.

Picture 14-3: Alarm list has been selected

Select the menu item ”Alarm list“ by using the cursor keys and OK.

You can also press the alarm key while in the main window. The screen below will then directly be shown. The window is showing all alarms that are currently active, sorted by the start time of the alarms.

Picture 14-4: Alarm list

737CE/1.94/01 Batch information

4-93

Chapter 4

Picture 14-5: List of historical alarms

For every alarm an alarm number, a time stamp, the alarm text, an alarm description and an alarm icon will be shown. The alarm icon describes the reaction (STOP,

HOLD, indication only).

After the reason for an alarm has been removed the alarm will automatically be reset and removed from the list.

Press the F1 key to obtain information on previously occurred alarms.

In system constant no. 002 ”max. number of alarms” the number of displayed alarms in the history list is limited (the default value is 50).

+

+

This list has a similar structure as the actual alarm list. Only an additional time stamp for the time the alarm was cancelled has been added.

Use the cursor keys to scroll trough the list or to scroll horizontally.

Press parallel the “up / down” cursor keys and the Alt key to scroll through the historical alarm list page by page.

Press F1 to return to the list of current active alarms.

In order to confirm an alarm please press the (F2) key. The time of confirmation will be displayed.

If applicable, active system alarms are quit at the same time.

Press the Esc key or the alarm key to close the alarm list window and to return to the main window.

4-94

Batch information 737CE/1.94/01

Batch information

14.3 Event list

Next to alarms there is other vital information available that will give on overall impression about the dye process. This information for instance includes, under more, if the power was switched off, if settings were changed or if someone switched from automatic to manual mode.

Select the menu item “Event List”.

Picture 14-6: Event list selection

A list with events will be shown. With the default settings the last 100 events will be stored. This value can be changed via the system constant No. 65 max No. of events

(from 50 to 10,000).

Picture 14-7: Event list display

737CE/1.94/01 Batch information

4-95

Chapter 4

14.4 History

For the daily work in a dye house, it becomes more and more important to record and to analyze the complete batch dyeing process. With the recorded information, the dye house staff is able to control the dyeing process and to localize reasons for off-shade dyes.

The SECOM records data of the running process permanently and provides a process protocol for each batch. With analyzing programs available on a host system and on the controller, the dyeing process can be analyzed either online or in retrospective.

The logging is done on the controller. During logging of the data, the information related to the active batch is clearly assigned. Following data will be written cyclic to the batch protocol file:

• Analog values (e. g. temperature, pressure, speed, etc.)

• Digital values (e. g. mode of valves, pump on/off, etc.)

• Active alarms

• Current machine status (start/stop, addition, etc.)

In addition to the cyclic logging, the following asynchronous information is recorded:

• Start and end of an alarm

• Start of function and end of function including function parameters

• Start of addition and end of addition

• Changes to the set values due to manual intervention

• Start of batch and end of batch, Start/Stop

Picture 14-8: History has been selected

To display the process values of the running batch or of a historical batch press the F2

key.

Select menu item ”History“.

4-96

Batch information 737CE/1.94/01

Batch information

14.4.1 Batch selection

A window with the current running and the historical batches is displayed.

The number of the displayed batches depends on the configuration of the system constant no. 001 ”Max. number of batches”. The default value is 3).

Picture 14-9: Batch selection for the display of process charts

You will find the current batch marked with a green rectangle. Select the desired batch by using the cursor keys. Confirm the selection by pressing the F4 key.

A window with the process values will be opened.

14.4.2 Display of process values

Picture 14-10:

Display of process values

737CE/1.94/01 Batch information

4-97

Chapter 4

Picture 14-11:

Display of the process charts

The recorded data can clearly be displayed on the SECOM on a diagram with a maximum of 20 analog values and 20 digital values. How many and which curves and diagrams are available depends on the supplier of the controller/machine.

With the help of the cursor keys and OK, press the “left or right” field to move the line cursor along the time axis. The values on the time axis represent the batch run time. It starts with the batch start time. As a default 6 hours are shown in one window.

By selecting the double cursor fields you can move trough the time/temperature curve page by page.

By selecting the tab fields you can move the cursor to the start and to the end of the time/temperature curve.

When moving the time cursor, the date of the actual recorded process values is displayed on top of the window (in the example shown above it is ”22/05/2006”). At the right hand side next to the curve scale selection the time at the cursor position on the time axis is displayed (in the example shown above it is ”14:09:02“).

For each position of the line cursor the process values recorded at that time are displayed.

If an alarm occurs during the process an additional bar is displayed. This bar is displayed as long as the alarm is active. If you move the cursor to an alarm bar, the number and eventually the description of the alarm is shown.

4-98

Select the zoom fields by using the cursor keys and press OK. With the zoom fields you can change the horizontal time scale. You can zoom in to display a minimum of 6 minutes on screen and you can zoom out to display up to 4 days.

If the SECOM is switched off and a batch has not yet been finished (this might be the case at the end of a shift) a message is shown. It says that no data is available for this time period.

If there is a white vertical line and the text ”End of data” after the last data record, this means that there is no more data recorded for this batch.

For a historical batch this means that the batch was finished at that point of time. For a running batch it means that this is the last data record that has been logged.

Batch information 737CE/1.94/01

Batch information

In addition to zoom into the curve horizontally the SECOM provides also the feature to spread the vertical axis. By selecting the fields shown here with the help of the cursor and the OK key you can zoom into the vertical axis up to 8x.

If the vertical axis is spread you can use the fields shown on the side to move the display up and down the vertical axis, so being able to investigate the time/temperature curves etc. in detail. For selection please use the cursor keys followed by the OK key.

Select the “INFO” field with the cursor and the OK key to get more information of the currently selected batch or to go to the actual cursor position within the curve. A window will be opened.

Picture 14-12: Batch information at the current cursor position

The following information is displayed:

• Date and time of the current cursor position, controller state, function, alarm

(if any), temperature, batch reference number, assigned program, date of batch creation, start time, end time, batch runtime, stop time and logging cycle time.

By selecting the curve selection field with the help of the cursor and the OK key a menu will be opened where different diagrams can be selected. Please note that the availability of more than one diagram depends on the machine configuration and may vary from machine to machine. Also machine dependent is the data that will be shown in the additional diagrams. It may be analog values like pressure; tank levels etc, binary information like pump status (off/on), winch status etc. or a combination of both, analog and digital values.

Picture 14-13:

Selection diagram

737CE/1.94/01 Batch information

4-99

Chapter 4

14.4.3 Copy historical batch data

Historical batch data can be copied to a USB stick inserted into the front USB connector and can later be analyzed and printed by a computer equipped with the required software. The data can be copied for single or for all batches.

Picture 14-14: Batch data copy menu

14.4.3.1 Only one batch

To copy the data press the F1 key in the “Batch selection” window (see Picture 14-9,

on page 4-97).

4-100

A progress bar is shown and the batch data of the selected batch is copied to the USB stick.

If there is a problem with the USB stick (either not inserted or defect/unformatted) then the following message will be shown. Press the OK key, eliminate the problem regarding the USB stick and try again.

Picture 14-15: USB stick not ready

If the USB stick is out of memory, the following error message will be shown. In this case please delete unnecessary data from the stick and try the copy process again.

Picture 14-16: USB stick out of memory

Batch information 737CE/1.94/01

Batch information

14.4.3.2 All batches

In order to copy all available historical batch data to the USB stick another menu is used. From the main window please press the F1 key. Confirm the “Setup” field by using the cursor keys followed by OK and then the menu item “Copy logging data ->

USB”. You can use the cursor keys and the OK key to select the desired menu items as well. The data of all batches is written to the directory “Reports” on the USB stick.

Picture 14-17: Batch data copy menu

The errors and error messages that can appear during copying all batches are the

same as described under section 14.4.3.1 Only one batch. The directory “Reports” will

be created automatically if not available on the USB stick.

737CE/1.94/01 Batch information

4-101

Chapter 4

14.5 Program list

Picture 14-18:

Program list selected

The program list is displayed after pressing the F2 key and selecting it from the info menu. The window shows all program steps of the running or selected program.

Use the cursor keys and the OK key to select the menu item “Program list”.

Picture 14-19:

Program step list

The actual active step 2 is marked

All programmed steps of the current program will be shown. The step currently processed is marked with a blue line.

+

+

Each line includes information from left to right:

Step number, function description (main and parallel functions), function parameter and function set time.

You can use the cursor to scroll trough the program horizontally and vertically.

Use parallel the “up or down” cursor and the Alt key to scroll through the steps page by page.

4-102

Batch information 737CE/1.94/01

You will get a complete display of all the step information after selecting the step with the cursors and pressing the OK key.

Batch information

Picture 14-20: Step information

Step 2 fill quantity

Press parallel the “up / down” cursor keys and the Alt key to move to the next or to the previous program step.

Press the related number key to open a window showing the parallel function details.

+

+

Picture 14-21: Step information

Set values of parallel functions are displayed

Press the Esc key to return to the main window step by step.

The displayed program step information is related to the programmed functions. The displayed parallel functions might be different from the current running parallel function as shown in the main window as they may run asynchronous to the step they are programmed in.

737CE/1.94/01 Batch information

4-103

Chapter 4

14.6 Batch info

Picture 14-22: Batch info selection

In order to display general batch related information please select “Batch info” from the info menu or the F2 key. Use the cursor keys and the OK key.

Select the menu item ”Batch info“.

.

A list of batch related information like reference number, program number, batch creation, start and end time as well as batch texts and batch parameters will be shown. You can use the cursor keys to scroll through the information.

Please note that available information depends on the machine configuration and may vary from machine to machine.

Picture 14-23:

Display of batch info

4-104

Batch information 737CE/1.94/01

Messages

15 ALARMS ................................................................................... 5-106

15.1

A

LARM DISPLAY

..................................................................... 5-106

15.1.1

Alarm list ....................................................................... 5-108

15.2

S

TARTING THE CONTROLLER AFTER ALARMS OCCURRED

........... 5-110

15.2.1

Start the controller after a stop alarm ............................ 5-110

15.2.2

Start the controller after a hold alarm ............................ 5-110

15.3

A

LARM CLASSIFICATION

......................................................... 5-111

15.3.1

User alarms .................................................................. 5-111

15.3.2

Controller and measurement system alarms ................ 5-111

15.3.3

System alarms of the SECOM ...................................... 5-112

15.3.4

System alarms of the PLC ............................................ 5-117

Chapter 5

737CE/1.94/01 Messages

5-105

Chapter 5

15 Alarms

Alarms are announcements and alerts for the operator. They are announcing irregularities or problems with the dyeing process, regarding the machine or with the control system.

15.1 Alarm display

If the SECOM recognizes an alarm an alarm window is opened. An alarm text is displayed in the window.

Picture 15-1: Alarm window “Stop alarm”

Picture 15-2: Alarm window “Info alarm”

After the OK key or the Alarm key is pressed to confirm the alarm, the alarm window is closed again and the alarm confirmation time is stored.

Depending on the PLC program, the alarm window is closed automatically and the alarm message is confirmed automatically after the reason for the alarm has been removed.

If an alarm appears then next to the alarm window the alarm number will be displayed in the status line.

Picture 15-3: Status line during active alarm

If more than one are active at the same time, the alarm number with the highest priority will be shown in the status line followed by the total number of active alarms.

Picture 15-4: Status line with more than one alarm

Depending on the machine configuration, an alarm can have different effects on the running program.

5-106

Messages 737CE/1.94/01

Messages

There are three alarm effects on a running process:

STOP

The running program will be stopped and must be started again with the green start key after the reason for the alarm is removed.

INFO

The occurring alarm does not have any effect on the running program.

This kind of alarm gives a hint to the operator that there is an irregularity within the process.

HOLD

The advance to next step function is locked in the running program.

The status of the controller (display in status line 2) changes to

”HOLD”. The alarm number is displayed in the status line 1 and the green LED on the start key is flashing.

By pressing the OK key the user confirms that he has noticed the alarm. However, the alarm is still active. The displayed alarm number in the status line also shows this.

Only after the reason for the alarm is eliminated, the alarm indication will be cleared!

737CE/1.94/01 Messages

5-107

Chapter 5

Picture 15-5: Alarm list selected

15.1.1 Alarm list

You can display the alarm list, which contains all current active alarms after pressing the F2 key.

Use the cursor keys and the OK key to select the menu item "Alarm list”.

Picture 15-6: Alarm list

Alternatively you can also press the alarm key while in the main window. The window below is opened directly showing the active alarms sorted by the alarm time.

5-108

For every alarm the alarm number, the timestamp when the alarm appeared, the alarm text, the alarm description as well as an alarm icon will be shown. The alarm icon describes the reaction (STOP, HOLD, indication only).

After the reason for the alarm is eliminated, the alarm will be deleted from the list above.

Messages 737CE/1.94/01

Press the F1 key to display the machine alarms that occurred earlier.

The number of displayed alarms depends on the configuration of the system constant no. 002 ”max. number of alarms” (the default value is 50).

Messages

Picture 15-7: List of historical alarms

This list is very similar to the actual alarm list, except that a time stamp for the alarm end will be shown additionally.

Press parallel the “up / down” cursor keys and the Alt key to scroll through the list of historical alarms.

Press the F1 key to go back to the actual alarms.

In order to confirm an alarm please press the F2 key. The time of confirmation will be displayed.

If applicable, active system alarms are quit at the same time.

Press the Esc key to leave the alarm window.

+

+

737CE/1.94/01 Messages

5-109

Chapter 5

15.2 Starting the controller after alarms occurred

15.2.1 Start the controller after a stop alarm

In order to restart the controller after a stop alarm occurred, you must confirm the alarm message on the display by pressing the OK key.

If this is done, you must eliminate the alarm reason.

You will find more information on alarms and how to remove them in this chapter item

15.3.3 System alarms of the SECOM, from page 5-112 onwards.

The alarm number is displayed in the status line. You can restart the controller by pressing the start key after the alarm reason has been eliminated.

15.2.2 Start the controller after a hold alarm

To restart the controller after a hold alarm occurred you must confirm the alarm message on the display by pressing the OK key.

If this is done you must eliminate the alarm reason.

You will find more information on alarms and how to remove them in this chapter 5

item 15.3.3 System alarms of the SECOM, from page 5-112 onwards.

The alarm number is displayed in the status line. After the alarm reason is eliminated open the alarm list by pressing the alarm key or by selecting menu item ”Alarm list”

(function key F2) in the info menu.

When the alarm list is displayed, press the function key F2 (QUIT). The controller mode changes to ”RUN” and the green LED on the start key is on.

5-110

Messages 737CE/1.94/01

15.3 Alarm classification

A total of 400 alarms are available on the SECOM. They are classified as follows:

• User alarms

• System alarms PLC

• Controller and measurement alarms

• System alarms SECOM

(No. 001 - 100)

(No. 101 - 150)

(No. 151 - 300)

(No. 301 - 400)

15.3.1 User alarms

Depending on the machine, up to 100 different alarms can be configured by your supplier during the project work. The alarm text and the effect of the alarms can be set up in the configuration.

Example: Fabric flow problem / overload winch drive

Dye kitchen tank not ready

Level sensor defective

You should find a list of your specific user alarms in your suppliers’ machine documentation.

15.3.2 Controller and measurement system alarms

The control and analog process routines of the connected PLC transfer alarms to the

SECOM when errors occur in the control loops and the analog channels.

Example: Gradient alarms (temperature control dye machine)

Measurement system failures (dosing ADD 1)

PT100 channel 2 defective

You should find a list of your specific controller and measurement system alarms in your suppliers’ machine documentation.

Messages

737CE/1.94/01 Messages

5-111

Chapter 5

5-112

15.3.3 System alarms of the SECOM

System alarms of the SECOM are generated if the software of the controller discovers problems, which are not directly related to the dyeing process. The SECOM distinguished between software and hardware problems.

Examples: Communication error to PLC

Wrong type of configuration

You will find a complete list of all system alarms below.

Alarm

-No.

Description Reaction Alarm group

301 no communication between SECOM controller and

PLC reasons:

- PLC is switched off

- faulty cable connection

- Arcnet terminator is not connected remedy:

- check and exchange cabling

- check Arcnet terminators

302 PLC has been exchanged remedy:

- will be reset automatically after the PLC has been initialized

303 battery of the CPU is empty remedy:

- exchange battery

308 the PLC does not have the required system software, no program execution possible remedy:

- exchange PLC system software

309 the PLC does not have the required system software, program execution possible, but not all features supported remedy:

- exchange PLC system software

310 the PLC is not equipped with the PLC boards that are configured in the machine configuration. remedy:

- check boards in the PLC or

- adapt the machine configuration to the actual equipment

311 the type configuration is not correct or has the wrong structure. remedy:

- transfer a correct type configuration

STOP

STOP

DISPLAY

STOP

DISPLAY

DISPLAY

STOP

Messages

10

10

10

10

10

10

10

737CE/1.94/01

Alarm-

No.

Description Reaction Alarm group

312 the machine configuration is not correct or has the wrong structure. remedy:

- transfer a correct machine configuration

313 Wrong PLC type connected that is not supported by the controller remedy:

- connect a different PLC

320 The PLC memory can’t be initialized or the control parameter (machine constants, timers etc.) can’t be transferred to the PLC. remedy:

- check the machine configuration

321 incorrect dye program remedy:

- acknowledge the alarm in the alarm list

- change the dye program

- create a new batch with the correct program

322 dye program does not correspond to the configuration remedy:

- acknowledge the alarm in the alarm list

- change the dye program

- create a new batch with the correct program

323 the executable dye program is incorrect. remedy:

- acknowledge the alarm in the alarm list

- create and start a new batch

324 a program step can’t be downloaded to the PLC. remedy:

- acknowledge the alarm in the alarm list

- restart the program on the same step

325 invalid controller state in the program execution of the SECOM controller remedy:

- will be reset automatically by the controller

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

10

10

10

10

10

10

Messages

737CE/1.94/01 Messages

5-113

Chapter 5

Alarm-

No.

Description Reaction Alarm group

326 power fail during the step change, the program step hasn’t been activated in the PLC remedy:

- acknowledge the alarm in the alarm list

- restart the program on the same step

327 error during return from an addition routine, wrong return address remedy:

- acknowledge the alarm in the alarm list

- restart the program on the desired step

STOP

STOP

328 error during calculation of a parameter formula, formula is wrong reasons:

- wrong formula

- wrong values (for example machine constants are not set) remedy:

- acknowledge the alarm in the alarm list

- check used values and correct formula if necessary

- start batch on another step or create and start a new batch

329 error during calculation of a function set time formula, formula is wrong reasons:

- wrong formula

- wrong values (for example machine constants are not set) remedy:

- acknowledge the alarm in the alarm list

- check used values and correct formula if necessary

STOP

DISPLAY

330 problem in accessing the file server directories remedy:

- check the connection to the file server (cables, cards)

- check that the directories are available and if the access right for the controller are set correctly

The controller cyclical tests this access. If the reason for the alarm has been removed the alarm will be reset automatically

DISPLAY

10

10

10

10

10

5-114

Messages 737CE/1.94/01

Alarm-

No.

Description Reaction Alarm group

331 not enough disk space for data logging. The logging will be interrupted until enough space is available. remedy:

- delete old batches

- The alarm is reset automatically, if enough disk space is available.

DISPLAY

332 parameter can’t be transferred to the PLC. remedy:

- acknowledge the alarm in the alarm list

- start batch once again

- correct configuration if necessary

STOP

STOP 333 parameter can’t be saved in a program. remedy:

- acknowledge the alarm in the alarm list

- please check program memory and configuration

- start batch once again

334 parameter can’t be saved in a program. remedy:

- acknowledge the alarm in the alarm list

- please check program memory and configuration

- start batch once again

STOP

335 batch can’t be started remedy:

- acknowledge the alarm in the alarm list

- start batch once again

STOP

336 not enough disk space on the ram disk, the error log protocol will be interrupted until enough space will be available

DISPLAY remedy:

- please check, if there is an error log file

ERROR.LOG on the RAM disk. If yes, than copy this file to a memory card and give the information to SETEX.

- after that reboot the controller. The ram disk will be deleted automatically.

10

10

10

10

10

10

Messages

737CE/1.94/01 Messages

5-115

Chapter 5

Alarm-

No.

Description Reaction Alarm group

337 error reading the configuration error reading one of the configuration data records remedy:

- Check the configuration with the Typeconf Tool and correct it if necessary

338 Not enough memory to store the status information remedy:

Finish batch normally, delete batch data.

Check if alarm 330 exists and correct if necessary

STOP

DISPLAY

339 Warning! Batch change not possible!

Changing the log file after the set log time could not be performed

340 error reading/transferring module parameters remedy:

- Check placement/modules and correct if necessary

DISPLAY

DISPLAY

10

10

10

10

5-116

Messages 737CE/1.94/01

Messages

15.3.4 System alarms of the PLC

The SECOM announces errors of the connected PLC. The SECOM distinguishes between system alarm of the software and hardware installed on the PLC.

Examples: Communication problem to PLC

Battery PLC empty

You will find a complete list of all system alarms of the PLC below.

Alarm-

No.

Description Reaction Alarm group

101 Communication problem between controller and

PLC, e.g.: - defective cable

Remedy :

- check and repair cable connection

102 Fault in communication to the analog board.

No analog processing possible. No calibration data available.

Remedy :

- exchange analog board

103 Power fail > 2 sec. (cold start) occurred while the controller was on "RUN".

Remedy :

- is automatically reset after the controller recognizes the alarm.

104 Faulty instruction list.

Remedy:

- switch off PLC and restart. If this is not successful, the PLC program has to be transferred again from the programming station into the PLC.

105 Faulty placement of cards/modules

During the instruction list processing a board was not recognized or not found.

Remedy :

- switch off PLC and restart

- if necessary exchange boards

STOP

STOP

STOP

STOP

STOP

106 Timeout of the PLC program

The PLC program exceeded the max. cycle/run time (e.g. by an infinite loop).

Remedy :

- check the PLC program and correct it

107 Battery empty

Remedy :

- insert a new battery.

STOP

DISPLAY

10

10

10

10

10

10

10

737CE/1.94/01 Messages

5-117

Chapter 5

5-118

Alarm-

No.

Description

108 Problem when burning the EEPROM

Remedy :

- burn EEPROM again

109 Faulty function number on step download

Remedy :

- check and correct controller

- configuration

110 Faulty parameter number on step download

Remedy :

- check and correct controller

- configuration

111 communication error module 1

112 communication error module 2

113 communication error module 3

114 communication error module 4

115 communication error module 5

116 communication error module 6

117 communication error module 7

118 communication error module 8

119 communication error module 9

120 communication error module 10

121 communication error module 11

122 communication error module 12

123 communication error module 13

124 communication error module 14

Messages

Reaction Alarm group

DISPLAY 10

STOP 10

STOP 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

737CE/1.94/01

Alarm-

No.

Description

125 communication error module 15

126 communication error module 16

127 communication error module 17

128 communication error module 18

129 communication error module 19

130 communication error module 20

131 communication error module 21

132 communication error module 22

133 communication error module 23

134 communication error module 24

135 communication error module 25

136 communication error module 26

137 communication error module 27

138 communication error module 28

139 communication error module 29

140 communication error module 30

141 communication error module 31

142 communication error module 32

737CE/1.94/01 Messages

Reaction Alarm group

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

DISPLAY 10

Messages

5-119

Chapter 5

Alarm-

No.

Description Reaction Alarm group

143 Wrong PLC placement

The alarm will be set if in the PLC placement a difference between plcId and SecomId appears.

Please check if all modules are switched on or inserted correctly. Eventually adapt the placement on the controller.

DISPLAY 10

144 Faulty controller configuration in the PLC

The alarm will be set if in the PLC placement a difference between CoDeSysId and the SecomId appears.

Adapt the placement on the controller

DISPLAY 10

145 PLC was new initialized

(short power drop)

Remedy:

- will be reset automatically if the controller recognized the alarm.

DISPLAY 10

You will find a description of how to display and to quit alarms in item 15.1.1 Alarm list,

on page 5-108.

5-120

Messages 737CE/1.94/01

Messages

1