Arad Octave Installation manual
Add to my manuals
8 Pages
Arad Octave is a compact ultrasonic flow meter designed to measure water flow accurately. It features a long battery life of up to 10 years, a multi-line 9-digit LC display, and programmable flow rate and volume units. The Octave is suitable for various applications and offers precise flow measurement in both forward and reverse directions. With its IP68 environmental protection and wide operating temperature range, it can withstand harsh conditions. Additionally, the Octave provides both digital pulse output and a 4-20mA analog output for easy integration into different systems.
advertisement
I n s t a l l a t i o n M a n u a l
A Member of the
Integrated Metering Technologies
1.0
General and safety
• Do not install, operate or maintain this flow meter without reading, understanding and followingthe factory-supplied instructions. Otherwise, injury or damage may result
• Read these instructions carefully before beginning installation and save them for future reference.
• Observe all warnings and instructions marked on the product
• Consider handling and lifting instructions to avoid damage
• If the product does not operate normally, refer to the service instructions or to a qualified ARAD service engineer
• There are no operator-serviceable parts inside this product
2.0
Product liability and warranty
Arad’s standard products (the “Products”) are sold to Customer and are purchased by Customer under the terms of warranty set forth herein below:
1. Arad warrants that the Products shall, under conditions of normal use and when properly installed, administered , applied and maintained, be free from defects in material and workmanship (the “Warranty”), for a period of 12 months following delivery thereof to Customer (the “Warranty Period”).
2. Arad’s sole obligation and liability under the Warranty shall be limited to the replacement, the repair or the refund of the original purchase price, at Arad’s sole discretion, of any defective Products which are proven not to conform to the
Products’ specification and which are returned to the factory or service center designated by Arad during the Warranty
Period by the Customer after completing a failure report. All provided that written notice of such defect is given by the
Customer to Arad within 21 days after discovery thereof. Freight cost to such factory or service center will be paid by the
Customer and freight cost from such factory or service center to Customer will be paid by Arad.
3. Arad will not be responsible for and will have no obligation under the Warranty to any non-conformity of the Products, caused, in whole or in part, as a result of misuse, abuse, tampering with or modification of any of the Products and/ or by accidents, fault or negligence, improper administration, application and/or use, installation, service, repair and/ or maintenance of the relevant Products, by act of vandalism or by any causes whatsoever (including but not limited to environmental conditions) that are external thereto.
4. The foregoing warranty is a limited warranty and is exclusive and in lieu of all other warranties, express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose and shall constitute the Customer’s sole and exclusive remedy with respect thereto. Replacement or repair in the manner provided above will constitute fulfillment of all of Arad’s obligations with respect to the quality and performance of the products.
No dealer, distributor, agent or employee of either Arad or customer is authorized to modify these warranties. Such modification shall be null and void and shall not bind Arad for any and all purposes.
5. Except and to the extent provided under the warranty, in no event shall Arad be liable, whether in contract, tort or otherwise, for any damages, whether direct or indirect, consequential, incidental, special or punitive, resulting from any defect in the products, including, without limitation, loss of profits, business, income, anticipated savings, goodwill or other commercial loss, even if Arad had been advised of the possibility of such damages, except to the extent that such liability may not lawfully be excluded.
Customer shall be solely responsible for the selection, use, efficiency and suitability of the Products.
2
3.0
Items included with order:
• One OCTAVE ultrasonic flow meter, size as indicated on the packaging box, pieced together into a complete compact system (flow tube plus electronics)
• One OUTPUT module, either digital or analog (based on the customer’s order)
4.0
Supplied Documentation:
• Condensed installation and user manual
• Report of factory meter settings
• Certificate of calibration data
5.0
Unpacking and Inspection
• This product has been thoroughly inspected and tested before shipment and is ready for operation.
• After carefully unpacking the meter, inspect for shipping damage before attempting to install. If any indication of mechanical damage is found, immediately contact the responsible transportation service and your local ARAD
LTD. representative.
6.0
System Descri ption and Measurement Method
• The OCTAVE’s measurement method is based on an ultrasonic, transit-time, dual-beam sensor which determines the length of time it takes an ultrasonic sound wave to travel the distance between the two sensors located on the meter’s body. The two sensors function as both the sender and the receiver, each one alternating these functions so that the ultrasonic wave travels both with and against the direction of the flow. Since the ultrasonic wave travels slower against the flow than with the flow, the time difference of two waves traveling with and against the flow leads to determining the velocity of the water
• The OCTAVE ultrasonic flow meter is a battery-powered precision flow meter designed for linear, bidirectional flow measurement of water
• Flow measurement values can be transferred through the standard digital or analog output
• The OCTAVE can be set up for a wide range of applications
7.0
Mechanical Data
Maximum Working Pressure
Liquid Temperature
Precision Class
Configuration
Power Source
Environmental Protection
Display Units
Output (optional)
16
bar
0.1-50
°C
ISO
4064 rev.2005
Compact - The display is built in to the unit
2
D size Li-battery
-10
years life time
IP
68
, Ambient operation temp.
-25
°C
÷ +55
°C
Multi line
9
digit LC display (Programmable - m
USG, CuFt. Acre Feet, Flow rate and volume)
3
,
Programmable dual open collector pulse output
Powered loop
4-20
mA
3
Dimensions
Model
(mm)
Nominal size
(inch)
L – Length (mm)
B – Width (mm)
H – Height (mm) h – Height (mm)
Weight (kg)
194
40
9
50
2
200
165
Octave
50
Threaded
2
Threaded
300
113
155
35
8
210
90
11.5
65
2.5
200
185
210
90
13
80
3
225
200
223
103
15
100
4
250
220
H
H h
8.0
Mechanical Installation
8.1
Handling the flow meter
Important handling information:
• Do not lift the Octave by the electronic housing.
• Do not carry the Octave by his lid.
• Do not place the Octave on the electronic housing.
• When handling the Octave, avoid hard blows, jolts or impacts.
h
8.2
Installation: Location and Position
L
L
Flo w D irection
Flow D irection Proper Installation
B
B
4
Flow D irection
Wrong Installation
The following examples are Arad’s recommendations for achieving
top performance
“O” DN
Flow D irection
Zero ( 0) pipe diameters before and after elbows ( 90°)
2 DN
5 DN
Flow D irection
Minimum of five (5) pipe diameters after pumps
Flow D irection
Minimum of two (2) pipe diameters before and after
2 DN
Flow D irection
Minimum of two (2) pipe diameters before T connections
2 DN
Flow D irection
Minimum of two (2) pipe diameters after strainers
Zero ( 0) pipe diameters before and after elbows ( 90°) in vertical installations
5
9.0
Notes
• For proper flow measurements, the OCTAVE’s measuring tube should be completely full at all times. Non-wetted sensors show loss of signal. Though this will not cause damage to the meter, it will, however, not measure flow and display zero
• Flow direction: The OCTAVE is a bidirectional flow meter. Note the indicating arrow on the OCTAVE’s display for forward and backward flows
• In case of direct sunlight exposure, it is recommended to keep the lid closed, though no direct damage will occur with the lid open
• Do not expose the OCTAVE to excessive vibration. To avoid vibration, support the pipeline on both side of the meter
• Ambient working temperature: -25 to +55°C
• Water working temperature: 0.1 to +50°C
• To avoid measuring errors due to air in the flow tube, observe the following precautions:
• Since air collects at the highest point of the system, installation of the flowmeter should be at the lowest point
• Always install control valves downstream of the meter in order to avoid cavitation
• ever install the meter on a pump suction side in order to avoid cavitation
10.0
Pipe flanges
• Refer to the standard dimensional drawings for flange spacing, accommodating for the thickness of gaskets
• Install meter in line with the pipe axis. The pipe flange faces must be parallel to each other
• Permissible length deviation: Lmax - Lmin ≤ 0.5
mm ( 0.02” )
11.0
Start-up
12.0
12.1
Electrical Outputs
Pulse Output (Digital)
• The OCTAVE is delivered with dual pulse output
• Pulse Type – open collector that allows current loading of 200mA, and up to 50volt
• The pulse width is programmable with a maximum resolution value of 1ms
Octave Pulse Output Module Specification
Outputs diagram
1K
10R
1
1
1
Pulse Out#1
Pulse Out#2
GND
AG3
AG3
1K
6
10R
AG3
Output wire colors
Warning - Signal connection polarity is mandatory!
Red
Green
Black
Pulse Out#1
Pulse Out#2
GND
Pulse per selected quantity
0.0001
0.001
0.01
0.1
1
10
100
1000
Pulse Duration table
M3
Max pulse
width [ms]
1
10
90
125
125
125
125
125
USG
Max pulse width [ms]
40
125
125
125
4
Cuft
Max pulse width [ms]
3
32
125
125
125
A.F
Max pulse width [ms]
125
125
125
125
125
125
12.2 4-20
mA Module (Analog)
• The current output is a passive 4-20mA.
• 4 mA is always “ 0” (zero) flow and the 20 mA is factory programmable according to the customer requirements.. (If the customer did not specify, the
20 mA will be the maximum flow rate)
Output characteristics
Outputs Type
Supplied Cable Length
Loop supply voltage
Output Impedance
4-20mA passive current output
3 [meters]
12 - 24 [Vdc]
25 [MΩ] typ
Output characteristics
Outputs Type Open Drain
Cable Length
3 meters
(up to maximum of
100 meters)
Maximum Supply Voltage 50Vdc
Maximum power load 200mA
4-20
mA Outputs diagram
Octave
4-20mA
Module
Read-out
Instrument
Output wire colors
Warning - Signal connection polarity is mandatory!
Red
Black current loop + current loop -
12 - 24 [Vdc]
13.0
Digital Display
m
3
Volume units m3/h Flow rate units
Leak detector
Battery level
Flow direction
Alarm/Error
Output Mode
Coil/3G/GSM - Active communication
7
14.0
Output Module Installation
If your Octave order includes output module, the following will explain how to attach it to the meter.
Output module kit includes (Pic.1)
1. Output module
2. 2 Allen Screws 3mm X 20mm
3. O-ring
4. Sealing cap
5. 3mm Allen key
Pic. 3 Stage 1:
Using the 3mm Allen key disassemble the cover (Pic. 2) from the meter, keep the cover the screws and the O-ring for future use (Pic.3).
Pic. 2
Stage 2:
Place the O-ring in the groove (Pic.4 & 5).
Pic. 4 Pic. 5
Pic. 7 Stage 3:
Insert the output module into the plug (Pic.6), and tighten the screws with the 3mm Allen key (Pic.7).
Pic. 6
Stage 4:
Push the sealing cap to the lower hole of the module
(Pic.8) and fixed it all the way in with a hammer (Pic.9).
Pic. 8 Pic. 9
Innovation through precision, quality and performance
Arad Ltd. Association Dalia Ramot-Menashe, 19239 Dalia, ISRAEL
Tel: (972)4-9897911 Fax: (972)4-9897965 w w w. a r a d . c o . i l
advertisement