advertisement
AUTOMATIC DOOR
M200
(KAPV SP / KAPVE SP)
Instructions
Manual
Automatic Door M200
English
PLEASE READ CAREFULLY BEFORE
ANY ASSEMBLY OR INSTALLATION
VER.: 1.2
REV.: 02/2014
Content
Warning to installer and user
1. Characteristics & Technical Data
2. Power Beam Sectional View
3. Glass production
4. Power Beam Device Component List
5. Power Beam Parts Positions
6. Power Beam Installation
7. Door Leaf Hanging
8. Door Leaf Adjusting
9. Belt Tensioner Installation
10. Door Halter Installation
11. Connection Scheme
12. Emergency battery wiring scheme (optional)
13. The installation of safety sensor (optional)
14. Connections of all devices with the PCB ML
15. Switch of Power Supply, Control Device & Motor Connection
16. Bi-Doors Inter-locking Connection Diagram
17. Program selector diagram
18. Graphic: Programming control unit
19. Control System Functions Setting
20. Connections Photocells module
21. Connecting Microwave sensors
22. The abnormal status & the resolving methods
Automatic Door M200
English pg. 14 pg. 15 pg. 15 pg. 16 pg. 16 pg. 17 pg. 18 pg. 19 pg. 03 pg. 04 pg. 06 pg. 07 pg. 08 pg. 10 pg. 11 pg. 13 pg. 19 pg. 20 pg. 21 pg. 22 pg. 23 pg. 24 pg. 26
Page 02
Automatic Door M200
English
Warning to installer and user
1) WARNING: It´s very important to your safety that this instructions are followed.The bad installation or wrong appliance can damage people or materials.
2) This product was designed and produced strictly for the use indicated in this manual. Any other use then expressly mentioned may damage the product and / or be a hazard to people, and void the warranty.
3) ELECTROCELOS is not responsible for the incorrect use of the product or by using other than that for which it was designed.
4) Do not install the product in an area where there is danger of explosion: gases or flammable fumes are a serious security threat.
5) ELECTROCELOS is not responsible if the safety standards weren´t taken into account in the manufacture of the element to be automated, or any deformation that may occur at the same.
6) Before the installation, turn off the power.
7) The devices (ex: photocells) should be used for prevent injury in people or materials.
8) ELECTROCELOS is not responsible for safety and proper operation of the product when isn´t used components sold by itself.
9) Do not make any changes to motor components and accessories.
10) The installer should inform the customer of how to operate the product in an emergency case and provide the manual of it.
11) Do not let children closer to the door when in motion.
12) Keep controls out of reach of children, to prevent any accident.
13) You shouldn´t in any circumstances, attempt to repair or modify the equipment. Must call a qualified technician for that job.
14) The equipment should be installed protected from elements such as: water, rain, humidity or excessive dust.
15) Equipment must be connected to earth ground.
16) Equipment for indoor use only.
Page 03
Automatic Door M200
English
1. Characteristics & Technical Data
- Intelligent Automatic Door - Auto programmable and with adjustable parameters.
- Low noise level - Replaceable rubber guide base.
- Firm movement , ABS Braking - Virtually no noise.
- Auto reverse when hitting an obstacle.
- Unic electronic motor lock - Locking force of approximately 800N.
- Lower Power Consumption - Approximately 10W in Standby.
- 36V brushless motor - High efficiency, high strength and long life.
- Bi-Door Interlocking - One of the doors remains closed (interlock between doors).
- Program selector with 5 available functions: Fully closed, Fully open, Partial opening, Automatic,
Entry/exit only.
- Emergency Battery optional - Allows emergency opening in case of 230V power failure.
- Auxiliary functions - Compatible with most access control systems.
- Satin finish.
- Adapted for varied climates.
- Simple installation.
Objectives focused by the designer:
- Reverses automatically when hiting obstacle in the path - Security in first place.
- Move Steadily - Low noise level
Page 04
Automatic Door M200
English
1. Characteristics & Technical Data
Specification
Door Body Type
Door Weight
Door Width
Type of Use
Power Supply
Opening Speed
Closing Speed
Bounce Time
Pause Time
Airproof Force
Electronic Lock Force
Motor Rated power
Standby consumption
Functions
Working Temperature
1 Leaf
Max. 200Kg
DW = 700 ~ 2000mm
Surface Mouting Type
2 Leafs
Max. 100Kg/leaf
DW = 650 ~ 1500mm
Intensive Use
AC230V +/- 10%, 50 ~60Hz
300 ~ 500 mm/s (Adjustable)
250 ~ 500mm/s (Adjustable)
< 1s
1 ~ 20s (Adjustable)
> 70N
Approximately 800N
100W
Approximately 10W
Fully closed, Fully open, Partial open, Automatic, Entry/exit only
- 30º C ~ 50º C
Page 05
2. Power Beam Sectional View
Aluminum profile type: M0103 (Length: 4200mm or 5800mm)
108
Automatic Door M200
English
31
10
20
(28∼44 variable)
Until the center of the leaf
( Leaf movement )
Pag. 06
3. Glass production
Ø16
150
20
(We recommend the use of tempered glass)
Automatic Door M200
English
Page 07
Automatic Door M200
English
4. Power Beam Component List
- The following components attached in the packing boxes
Item Part Number Schematic Drawing
Quantity
Note
Glass Profile
M PERFIL V
2
Batteries
Power beam Model
Cover Profile
Motor
Belt Tensioner
Cradle parts
M BAT
M0103
M0103T
M0901
M0201
M0401 4
1
1
1
1
3 3 x 12V 1,2Ah
Standard 4200mm
Standard 5800mm
Standard 4200mm
Standard 5800mm
Normally 2pcs per door
Upper Connection Parts
Lower Connection Parts
Belt
Controller
Door Halter
Switch of power supply
Microwave Sensor
M0501
M0502
M0301
M0802
M0601
M1201
M1601
MOTORLINE
1
1
4
1
1
1
2
Page 08
Automatic Door M200
English
4. Power Beam Component List
- The following components attached in the packing boxes
Item Part Number Schematic Drawing
Quantity
Note
Photocells Module
CR10MS
FREQUENCY WORK
FREQUENCIA TRABALHO
1/2 f
f
GAIN/GANHO 100%
GAIN/GANHO 50%
N.C. CONTACT
N.O. CONTACT
LED
GAIN / GANHOS
10% - 50%
+
12 Volt
24 Volt
1
Photocells FOTO9S1A 1par
Door guide M2125 2
Program Selector M CELE 01
1
3
F U N C
2
4
1
O
Optional
Electric Lock
Electric lock controller module
M ELE 02
M FE 03 O Optional
Page 09
Automatic Door M200
English
5. Power Beam Parts Positions
All mounting parts position are basically as follows:
(Single Door Leaf Type)
Belt Tensioner Lower Connection Parts(Right)
Upper Connection Parts(Left)
Control Device Motor Device
Door Halter Cradle Parts Belt Door Halter Switch of Power Supply
(Double Door Leaf Type )
Belt Tensioner
Belt
Upper Connection Parts
Cradle Parts
Lower Connection Parts Control Device Motor Device
OWNIC AUT
Cradle Parts
Door Halter Door Halter
Switch of Power Supply
Page 10
Automatic Door M200
English
6. Profile Installation
(Surface Mounting)
The surface must vertically and horizontally leveled to ensure the proper functioning condition.
- Set the M0103 profile to wall using at least 8mm screws
(1) Make holes in the profile and in the wall in order to fix power beam.
Use a level to verify that the profile is perfectly level.
(2) Pay attention to the passage of electrical cables and signal in order to prevent them from being damaged by moving parts.
Profile
End cover
(Not Standard Configuration)
400
400
400
400
400
Cover
(Not Standard Configuration)
Page 11
6. Profile Installation
POSSIBLE APPLICATIONS:
Automatic Door M200
English
11
21
Page 12
Automatic Door M200
English
To adjust the leaves, follow the steps below:
(1) Loosen the screw A to lower the support in relation to cradle
(2) Hang the door leaf in the profile
(3) Ensure that the nylon wheel of the cradle will roll down right along the curve track.
Pressing Wheel
Door Top
(Single door leaf type)
Cradle parts Cradle parts
Cradle
Height adjustment screw (C)
Screw (D)
120
Cradle parts
(Bisection type)
Cradle parts Cradle parts
Cradle parts
Screw (D)
Screw (A)
Page 13
Automatic Door M200
English
Adjusting steps:
(1) Left and right side cradles should be installed in a straight line.
(2) After hanging the door leaf on the power beam, check if the door leaf slides to left or right side.
(3) With the door leaf hung on the sliding guide, it should be open and close by hand in order to verify if exists friction.
(4) The movable door leaf has to be hung vertically.
- When the space between the movable leaf and the fixed parts is not desired, you can adjust using screws D from the cradle (See previous page).
- When the movable door leaf are declining as the following diagram, you can adjust it relieving bolts A and B and turning the screw C.
(5) No friction is allowed on the movable door.
Attention: No oil can be used on the sliding guide.
Screw (D)
Cracks
Height adjustment screw (C)
Screw(B)
(Up ) (Down)
Cracks
Screw (A)
Screw (D)
Leveling and adjusting leafs:
(1) Loosen the screws A and B from bracket.
(2) Turn the screw C to adjust height
(3) Tighten the screws A and B after adjustment.
Page 14
(1) Check the tightness of the 4 screws (F) and (G)
(2) Adjust screw (D) to reduce or increase belt tension.
(3) Belt may get prolonged after a long time of use. In this case, belt tension has to be renewed by repeating the above steps (1 and 2).
Screw
(D)
Screw
(E)
Screw
(F)
Belt
Ajusting Panel Limiter
(F)
Terminal
A
Screw (G)
(F)
Screw
(H)
Automatic Door M200
English
Switch of Power Supply
10. Door Halter Installation
(1) Define the closing position of the door by installing the stopper.
(2) The position of the stoppers is as follows.
(
Single door leaf type
)
Door Halter
(
Bisection type
)
Door Halter
Door Halter Door Halter
Page 15
Automatic Door M200
English
11. Connection Scheme
!WARNING! : All the connections should be operated under cutting off the 230V power supply.
Control Device
M0802
0V
(Battery , Accessories)
+36V (Battery)
+15V (Accessoies power supply 600mA)
Function of Bi-door Inter-Locking
Partial-opening terminal
Do not use (For Future use only)
Input for photocells (NC)
Full opening terminal
Common
Anti Panic Function
Do not use (For Future use only)
Note: Exit 6 and 7 are only for Anti Panic automatic glass doors. If not using this function, place a shunt between the 2 exits.
Battery
0V
36VDC
9
10
Controller
The batteries are only for the following cases:
1 - Open the door automatically in case of 230V power failure.
2 - Electronic lock when closed, for a limited time in case of 230V fault.
For this select K2 ON or K2 OFF.
K2 ON - In the presence of batteries, door opens automatically in case of 230V power failure.
K2-OFF - In the presence of batteries, door remains closed in case of 230V power failure.
Page 16
Automatic Door M200
English
13. The Installation of Safety Sensor (optional)
(1) Make holes in the pillar, making sure that holes will keep photocells lens in the same horizontal level.
Attention: The mounting distance should be within 7meters.
Installation height is 600mm, when using single circuit.
Installation height is 300mm & 900mm, when using double circuit.
Horizontal Line
Within 7m
Pillar
Fasten
Connection Wire
Guide
Pillar
Page 17
Automatic Door M200
English
14.
Connections of all devices with the PCB ML (OPTION 1)
Page 18
Automatic Door M200
English
14.
Connections of all devices with the PCB ML (OPTION 2)
Page 19
Automatic Door M200
English
Controller Motor Device Switch of Power Supply
16. Bi-Door Inter-Locking Connection Diagram
Double doors - After the closing of one door, another opens (Inter-Locking)
With this connection the 2 doors are never open at the same time.
Controller (M0802)
12-13
13-12
14-14
Page 20
Automatic Door M200
English
11. Belt Parts Installation
Fully Lock
Button
Partial Open
Button
1
3
F U N C
2
4
LED
Fully Open
Button
Automatic
Button
Unidirectional
Button
P R O G R A M S W IT C H F O R A UT O -DO O R
MO DE L :M -2 03F W IN F O R T E C H N O L O G Y
+V DD
G ND
AC C E S S
O U T-S W
IN-S W
P U S H
C O M
N O
P C O M
P N O
2 3
5 6
DC 12 30V
Initialization Reset Button
Screw fixed hole
5
Terminals
Screw fixed hole
(Frontal Panel)
(Back Panel)
• Five-range program selector
• DC15 power input
• Easy instalation and use
• Function switch against password
• With memory function in case of power failure
• Instruction with indicator light to confirm operation validity.
“FULLY LOCK”
“ FULLY OPEN”
6
“HALF OPEN” - Outdoor and indoor sensors are enabled - Door only half open
“
UNIDIRECTIONAL
” - It allows to disable one of the microwave sensors according to direction
“AUTOMATIC” - Indoor and outdoor sensors are enabled.
Changing operation mode:
- Press the "FUNC" key for 5 seconds - Led indicator turns green - Enter password (original password is 1234).
Reconfirm by pressing the "FUNC" button again - Select the function you need from the five available FULL LOCK /
FULL OPEN / HALF OPEN / EXIT ONLY / AUTOMATIC.
Setting Management password:
- Press the "FUNC" key for 10 seconds - Selector will emit sound between 5 and 10s - Enter correct password.
Reconfirm by pressing the "FUNC" button again - Enter new password and press "FUNC", reconfirm the new password and pressing "FUNC" key (New password setting completed successfully).
Note - If you have forgotten your password, open the rear panel and press the RESET button for 40 seconds.
The initialization of the system is confirmed by sounding a beep. Password back to 1234.
Page 21
Automatic Door M200
English
(Bisection type)
After assembly completed, open and close the door several times by hand before connecting to main power supply 230V in order to assure that there is no obstacle during opening and closing.
After checking the proper motion of the leaves, can now move to the programming, which is made automatically.
Wait about 3 seconds
Door will open and close at low speed
Wait until door stops at close position
In case of controller receives an order from sensor or obstacle before finishing maneuver recognition, it will repeat the whole process again
Page 22
Automatic Door M200
English
Adjust steps and warnings:
1. Open and close the door for several times with hands before turning on the electricity to make sure there is no unconviniently during the process of opening and closing.
2. If there is safe power, you can enable/disable according to K2 switch position.
3. You must adjust the rebound force (F) according to door leaf’s weight and running speed.
4. When adjusting speed, you must also adjust rebound force in order to avoid the door taking for meets barriers bounde to present repeatedly movement.
5. At the beggining, the opening time should be selected to the mínute. This parameter will be easier adjusted after the other parameters have already been selected.
A B C D E F
K
1
K
2
K
3
K
4
Controller M0802
MOTORLINE
A - Indicator light
B - Hand handling button (Start)
C - Door opening speed adjustment
D - Door closing speed adjustment
E - Pause time adjustment
F - Rebound force adjustment
K1, K2, K3, K4 in OFF condition (default)
K1. K1 button in ON, by receiving signal from the radar, the door will open and only will close after receiving a second pulse.
K1 OFF - Automatic Mode: The door opens to the 1st radar signal and closes automatically after expiry preselected pause time.
K2. If emergency battery present, the switch K2 in ON will keep the door open in case of power failure
230V. K2 OFF, in the event of 230V power failure, the the door remains closed.
K3. ON / OFF - Selects the direction of the door opening.
K4. Choosing closing force.
Page 23
Automatic Door M200
English
ELHO / VERM
LHA /MA
NCO
LHA /MA
/ BRA
Page 24
Automatic Door M200
English
21. Connecting Microwave sensors
1 General information
LED
- flashes after power-on
- lights up during detection
Sensitivity potentiometer
JST-connector
Red
12-24V Power Supply
Yellow
Relay (COM)
Relay (NO)
2 Adjustments
1
The sensitivity settings determine the size of the sensing field
Planar antenna
for wide detection field
MIN
MIDDLE
MAX
1.5
3
4.5
3 1.5
0 vertical angle: 30°, mounting height: 2.2m
2
The lateral angle of the planar antenna determines the position of the sensing field
4.5
3 1.5
0 1.5
3 4.5
1.5
3
4.5
3
The vertical angle of the planar antenna determines the depth of the sensing field
3 1.5
0 1.5
3
0°
15°
45°
30°
1.5
3
15°
30°
15° 30° 45°
4.5
45°
sensitivity: maximum
Page 25
Automatic Door M200
English
21. Connecting Microwave sensors
3
Installation tips
Avoid vibrations!
4 Troubleshooting
SYMPTOMS
The door will not open and no red LED lights up.
The door opens and closes constantly.
Avoid moving objects in
proximity of the sensor!
Avoid HF lamps or fluorescent lighting in proximity of the sensor!
PROBABLE CAUSES
The sensor power is off.
Avoid touching electronics!
CORRECTIVE ACTION
Check the wiring and the power supply.
The door will not close.
Red LED is OFF.
The sensor "sees" the door moving.
When closing, the door creates vibrations picked up by the sensor.
ON-OFF switch at door control is in wrong position or faulty.
Improper output configuration.
Revolve the with small strength.
Increase the tilt angle and/or reduce the sensitivity.
Make sure that the sensor is correctly fixed.
Reduce the sensitivity.
Make sure that the ON-OFF switch for the door is in the ON or
AUTOMATIC position. Check the output configuration setting on each sensor connected to the door operator.
5 Technical specifications
Technology
Transmitter frequency
Transmitter radiated power
Transmitter power density
Maximum mounting height
Tilt angles
Detection field (mounting height=2.2m)
Detection mode
Minimum speed
Supply voltage
Mains frequency
Power consumption
Output relay (free of potential change-over contact)
Max. contact voltage
Max. contact current
Max. switching power
Hold time
Temperature range
Degree of protection
Norm Conformity
Material
Color of housing
Dimensions
Weight
Length of cable
: microwave and microprocessor
: 24.125GHz
: <20dBm EIRP
: <5mW/cm²
: 3.5 m
: 0° to 90° vertical and -30° to + 30° lateral
: 6m (W) x 3m (D)
: motion
: 5 cm/s (measured in the sensor axis)
: 12V to 30V AC/DC +30% / -10%
: 50 to 60 Hz
: < 2W (VA)
: 42V AC- 60V DC
: 1A (resistive)
: 30W (DC) / 60VA (AC)
: 1.0 s
: IP54
: R&TTE 1999/5/EC; EMC 89/336/EEC
: ABS
: black smoked, aluminium finish
: 120mm (W) x 80mm (H) x 50mm (D)
: 0.265kg
: 2.5m
Page 26
Automatic Door M200
English
22. The Abnormal Status and the Resolving Methods
When the auto-door unconventionally runs, please cut off the power supply for a few seconds, and then turn on again.
Nº Abnormal Status
1
The door cannot move
Possible cause
1. Power failure
2. Door blocked
3. Damaged fuse
4. Cables desconnected
Resolving Methods
1. Check the 230V power supply.
2. Separate the door from belt and check if door can be moved by hand
3. Check fuse M1201
4. Make sure the cables are securely connected
3
2
Door open and close with very low speed
1. Leafs with friction
2. Cradels with damaged bearings
3. M0201Group tensioner with damaged bearings
4. Defective control unit
5. Motor with stuck reducer
Door cannot be closed
1. Sensor sending continued signal
2. Photocells always open
1. Move the door manually, without being attached to belt and verify proper operation.
2. Repeat the previous step
3 Remove belt and check by hand if the movement is correct.
4.Change the position of the potentiometers D and C see whether the unit changes the operation.
5. Without the belt and without power, make sure the motor turns manually
1.Unplug one radar ,one by one to see if the door close
2. Check if the cables connecting photocells module to control unit (1 and 2) close the circuit NO.Install
an shunt between point 1 and 2 and make sure the door close.In case it closes verify power suplly cables
4
Door reverse direction when closing
1. There are obstacles in the sensor detection area.
2. The door leaves are within the detection area.
3. Photocells misaligned
4. There is friction in some door components
1. Remove obstacles in the area of the detection sensor.
2. Adjust the sensor detection area and sensitivity
3. Align the photocells
4. Check, moving leaves by hand, where exists contact between components
5
Door leafs slam violently
- Lack of stoppers
- Faulty control board
- Check if the stoppers are tight and in place;
- Change the position of the potentiometers C and D in order to see whether the switch changes control unit operation.
- Reset control board by disconnecting batteries and
230V power supply for 5seconds.Power
on again, the door will start new programming.
Page 27
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project