JUNG TK-SIP-10REG DCM SIP gateway Operating instructions

Add to My manuals
12 Pages

advertisement

JUNG TK-SIP-10REG DCM SIP gateway Operating instructions | Manualzz

Product information

SIP-Gateway

for 115 call destinations

FBI6100-0400

for 10 call destinations

FBI6101-0400

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

2 01/2013

Table of contents

Scope of delivery ................................................................................................................. 2

Please observe! ............................................................................................................ 2

Safety instructions................................................................................................................ 3

Connections, indication and operating elements ................................................................. 3

Device overview ................................................................................................................... 5

Technical data ..................................................................................................................... 5

Intended use ........................................................................................................................ 6

Short description .................................................................................................................. 6

Connect the lines ................................................................................................................. 6

General notes ................................................................................................................... 6

Connect the TCS system ................................................................................................. 6

Connect the network ........................................................................................................ 6

Wiring example operation mode ACTIVE ......................................................................... 7

Wiring example: operation mode PASSIVE ..................................................................... 7

Commissioning .................................................................................................................... 8

Note .................................................................................................................................. 8

Error detection and indication ........................................................................................... 8

Start browser: connection establishment PC

– SIP Gateway .............................................. 8

Prepare the ethernet connection ...................................................................................... 8

Enter / change IP address ................................................................................................ 9

Change the password ...................................................................................................... 9

Enter / change SIP settings ............................................................................................ 10

Configure the telephone book ........................................................................................ 10

Adjust the switch time door opener and light relay ......................................................... 11

Programming the TCS front-door station ........................................................................ 11

Operation ........................................................................................................................... 11 door call from front-door station ..................................................................................... 11

Call from a telephone to a front-door station .................................................................. 12

Reload to factory settings ............................................................................................... 12

Service ............................................................................................................................... 12

Scope of delivery

1 x FBI610x-0400

1 x product information

Please observe!

This product information describes all necessary steps to connect the FBI610x with a

TCS front-door station and with a SIP server.

For detailed information refer to the FBI610x user manual.

You’ll find the manual for free download under www.tcsag.de.

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

01/2013 3

Safety instructions

!

Attention! Mounting, installation, commissioning and repair of electronic devices have to be carried out only by qualified electricians. Thus, the current standards for the installation of door communication systems must be observed!

For working with main connection of 230 V alternating voltage, the safety regulations according to DIN VDE 0100 must be observed.

When installing TCS:BUS systems, the general safety regulations for telecommunication systems according to VDE 0800 must be observed. Inter alia:

separated conduit of heavy and low current lines,

minimum distance of 10 cm in case of a common cable conduit,

use of separators between heavy and low current lines within shared cable ducts,

use of standard communication lines, e.g. J-Y (St) Y with 0.8 mm diameter,

existing lines (modernisation) with deviating cross-sections can be used in compliance with the loop resistance.

!

With suitable measures to protect against lightning, it has to be ensured that a voltage of each 32 V DC is not exceeded at the a- and b-wire.

Connections, indication and operating elements

19|20

Labelling connection for supply voltage

Function

only operation mode ACTIVE: 8 - 12 V AC (from bell transformer NWV1000-0400)

23|24|25 a*/b*/P* connection TCS:BUS

ACTIVE

only for operation mode ACTIVE!

The SIP-Gateway realises the supply voltage for a

BUS strand.

In this operation mode, a front-door station can be connected to the network at minimal expense.

One audio front-door station (incl. extensions) and 3 audio indoor stations can be operated in this mode.

The selection of connectable devices must be realised in compliance with the max. offset current output of the FBI610x.

Terminals are short-circuit protected.

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

4 01/2013

28|29|30

21|22

26|27 a/b/P connection TCS:BUS

PASSIVE

Door release relay

(potential-free relay contact

– closing contact)

Internal light switch relay (potential-free relay contact

– closing contact)

Only for operation mode PASSIVE!

The supply voltage for the TCS:BUS is provided by an additional power supply and control unit.

This operation mode is selected if the SIP-Gateway is integrated into e.g. a video system, a system with several front-door stations, resp. if the system which is to supplied exceeds the power output of the SIP-Gateways.

Terminals are short-circuit protected.

door release voltage via bridge terminal 20 to 21

12 V, 50/60 Hz / 2 A (for door opener not smaller than 6 Ohm)

door release time can be adjusted: 0 to 99 sec

function can be adjusted via web interface

To control automatic light switching units, the following extensions can be connected:

automatic light switch unit (max. permitted contact load capacity of 24 V DC / 1 A)

staircase light control unit FNA1000 (or TZ1-SG)

(with 8 - 24 V AC)

relay

adjustable light switch time: 0 to 99 sec

adjustable function via web interface

connection for network (PC/Laptop) RJ45 socket

RUN

PROG

ERR

2

3

4

RUN/PROG push button

RUN/PROG indication

(LED orange) error indication at

TCS:BUS (LED red)

only for operation mode ACTIVE!

switching to the system mode: operation mode – programming mode

indication of the system mode:

lights up: operation mode

blinks: programming mode

flashes: error in the connection to the TCS:BUS

(see page 8)

flashes OFF: error in the network connection (see

page 8)

lights up: operation voltage is present indication operation voltage (LED green) indication status voice connection (LED orange) error indication SIP

(LED red)

indication voice connection or connection establishment FBI610x to an external device status indication (LED green) status indication (LED orange)

lights up: start process (around 40 sec long) or no

connection to the SIP server (see page 8)

blinks: if data is sent or received via LAN

lights up: connection FBI610x to the network is established

lights up simultaneously green with status indication: no connection to the network

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

01/2013 5

Device overview

connection supply voltage error indication at the TCS:BUS

(LED red) connection RJ45 status indication

(LED green) status indication

(LED orange)

RUN/PROG indication

RUN/PROGpush button indication for operation volatge (LED green) error indication

SIP (LED red) indication for status voice connection (LED orange)

Technical data

housing: weight:

DIN-rail housing 6 SU for DIN-rail according to

DIN EN 60715 TH35

215 g acceptable ambient temperature: 0 °C ... +40 °C degree of protection: IP 20 operation mode ACTIVE supply voltage: output voltage idle state: output voltage speaking:

8-12 V AC (from bell transformer NWV1000-0400)

U(a/b) = 24 V ± 1 V, U(b/P) = 26V ± 1V

U(a/b) = 22 V ± 1 V

I(a) =40 mA,

I(Pmax) = 180 mA output current: max. output current: operation mode PASSIVE: supply voltage: input current: max. input current:

+26 V ± 8 % (power supply and control unit)

I(a) = 0.05 mA, I(P) = 27

I(Pmax) = 45 mA mA

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

6 01/2013

Intended use

The FBI610x is an interface for the connection of TCS front-door stations to a VoIP network as end device (client) via Session Initiation Protocol (SIP).

The SIP-Gateway can be used generally in 2 operation modes at the TCS:BUS: operation mode ACTIVE or operation mode PASSIVE.

Short description

providing the voltage supply of 24 V DC (for TCS:BUS, only operation mode ACTIVE)

switching to the system mode between operation and programming mode,

LED indication (only in operation mode ACTIVE).

automatic detection of the operation mode PASSIVE or ACTIVE

potential-free relay contacts (closing contacts) to control automatic light switch units / door opener

single speech channel:

Communication from front-door and indoor stations to more than one call destination is not possible simultaneously.

optical indication for voice connection and operating voltage

error detection and indication for TCS:BUS and network errors

Connect the lines

General notes

!

Use a small screwdriver to connect the lines and to avoid damaging the device.

Connect the TCS system

Isolate the ends of the lines.

Connect the TCS system to the FBI610x in compliance to the operation mode and the type of system completely and according to the wiring example.

Connect the network

Establish a connection between the RJ45 interface at the FBI610x and your network by using a patch cord.

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

01/2013

Wiring example operation mode ACTIVE

7

Wiring example: operation mode PASSIVE

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

8 01/2013

Commissioning

Install the devices of the system completely.

Check the a-, b- and P-wire against each other for short-circuits.

Switch on the mains voltage.

After switching on the voltage supply, the FBI610x starts automatically.

Note

!

!

The SIP Gateway restarts automatically after a voltage interruption, even if the device was switched off.

Switching off the power supply during a storage process or software update can cause a loss of data or a malfunction of the device.

Error detection and indication

Error at the TCS:BUS

Only operation mode PASSIVE: a-wire is not connected / not supplied, a-b short-circuit or a- and P-wire are interchanged / short-circuited

Only operation mode ACTIVE: a-b or a-P short-circuited

ERR error indication flashes

(1:7, 1 Hz)

Connect a-wire / check power supply, interchange a- and P-wire or remove short-circuit, device is in standby mode again

Network error defective network connection or no connection to the SIP server

ERR error indication flashes out

(7:1, 1 Hz)

Check the network, check data transmission, check login data for

SIP server, device is in standby mode again

Network error defective network connection or no connection to the SIP server

4 error indication SIP

lights up *

Check the network, check the data transmission, check the

SIP server, device is in standby mode again

* No error during the start process, indication, lights up and expires after around. 40 sec if no error was detected.

Start browser: connection establishment PC – SIP Gateway

Prepare the ethernet connection

The PC/Laptop must be equipped with a network connection and the device must be located in the same subnet as the SIP-Gateway. If your network and server are working in the 192.168.1 address area (C net), you can directly access the SIP-Gateway (provided that another device does not use the IP address of the SIP-Gateway).

Otherwise the used PC/Laptop must be set temporary to an IP address within the address area of the FBI610x to establish a connection with the SIP-Gateway. To install / modify your network connection, please use the network installation assistant or the help menu of your operating system (buzzword: Install the network). If several FBI610x, which are in delivery state, are to be installed within one network, the devices must be commissioned one after the other and assigned to a free IP address.

To install the network connection, eventually you need administrator.

In delivery state, the following values are pre-set at the FBI610x:

IP address: 192.168.1.200, net mask: 255.255.255.0, password: 1234

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

01/2013

Open an internet browser.

Enter the IP address of the SIP

Gateway into the address line: http://192.168.1.200

The start page is called.

Select Settings VoIP.

Enter the password (preset:

1234) and click Register.

9

Enter / change IP address

Manually configured IP ad-

dress is already selected.

Enter a free IP address which belongs to the address area of the required network.

Enter the number of the related subnet mask.

Eventually enter also the IP address of your DNS server.

Confirm with Save.

The IP address can be obtained automatically via a DHCP (Dynamic Host Configuration

Protocol) server.

!

If the IP address was changed manually, eventually the web browser can no longer display the page with the feedback. If this is the case, enter the new IP manually into the browser to get back to the start page. Eventually, change the address area of your

PC/Laptop again.

Change the password

Register under Settings VoIP. Select System in the navigation bar.

Enter your new password into the field Administrator password. You can also remove the password if there is no need for security.

!

Please observe that without any password protection, the system can be manipulated by anyone!

Click Save.

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

10 01/2013

Enter / change SIP settings

Register under Settings

VoIP.

Select SIP settings in the navigation bar.

Enter here the necessary data for your SIP server / telephone system, which you have determined during the registration of the

FBI610x.

Click Save.

Note for user name:

This field is used only for information and does not have a special function. You can enter e.g. the position of the frondoor station here.

Configure the telephone book

Register under

Telephone book.

Enter your required call destinations for your connected front-door station

(see table below).

Click Save.

Column name

Function

This text is used only to inform the installer resp. for a better assignment of call number and serial number to a resident or a flat. This text is not displayed somewhere else. number Entry of the selected SIP telephone numbers without special characters. serial number TCS:BUS serial number, which is to be programmed at the front-door station. The serial number has max. 6 digits. Shorter serial numbers are entered and displayed without leading zeroes. incomming Decision, how to react in case of an incoming call of the corresponding number. The following can be selected: rejecting, automatic acceptance, automatic acceptance with playing a stored announcement (the caller can hear it) and manually acceptance. The additional opti on “pieps“ realises that conversation partners hear a signal tone after the audio connection is established. outgoing group ID

Decision, if in case of an outgoing call, a stored announcement (e.g. position of the communication system) should be played by the called person.

Via the group ID, 10 different call chains can be determined. Telephone book entries with the identic ID are handled as call chain. If an entry of this group is called by a front-door station and the call is not accepted, all entries with the same ID are called one after the other.

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

01/2013 11

Adjust the switch time for door opener and light relay

Register under Settings

hardware.

Select System in the navigation bar.

Select the values.

The switch time is to be adjusted by selecting numbers from

0…99 sec. The left selection field adjusts the 10th seconds, the right one the 1th seconds.

Programming the TCS front-door station

Program the serial numbers which are used in the telephone book of the FBI610x with c onfigo™ or TCSK-01 at the required buttons of your front-door station.

The buttons of the front-door station can be programmed also manually:

Switch on the programming mode of the system.

In the operation mode ACTIVE: Shortly press the RUN/PROG button at the FBI610x

or in the operation mode PASSIVE: Shortly press the RUN/PROG button at your power supply and control unit. The RUN/PROG LED starts blinking.

First delete already programmed buttons by pressing the button for a long period (see product information front-door station).

Call the FBI610x from the number which is allocated to the serial number in the telephone book. Select a front-door station.

After the voice connection is established, shortly press the bell button which is to be programmed. Despite a negative acknowledgement tone sounds at the front-door station, the button was successfully programmed.

!

This function is only available, if the corresponding telephone book entry under in-

coming is not set on Reject.

The incoming call number at the FBI610x must be identic with the telephone book entry.

Operation

door call from front-door station

An incoming call is directly connected to the front-door station by accepting the call at the called telephone (delivery state).

If the option confirmed ac- ceptance ( ’7’) was activated (activation see user manual), the button 7 must be pressed to accept the call. The controlling of the FBI610x is realised via the

MFV dial of the connected telephone.

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A

12 01/2013

Call from a telephone to a front-door station

A telephone can establish a connection to the FBI610x only if the incoming SIP telephone number is stored in the telephone book and the corresponding entry under

Incoming is not set on Re-

ject.

After the FBI610x has accepted the call, you have to select the front-door station via the telephone keypad.

See graphic Select front-

door station.

Using the binary output conditions a configuration, see user manual of the

FBI610x.

Reload to factory settings

!

When loading the factory settings all VoIP and hardware settings are reset. The entries in the telephone book remain unchanged.

IP address: 192.168.1.200, netmask: 255.255.255.0, password: 1234

Reload to factory setting yellow LED lights up

Press RUN/PROG button and hold it … yellow LED blinks keep RUN/PROG button pressed … yellow LED blinks fast

…, until LED blinks, then release yellow LED lights up factory settings loaded

Service

!

Please use first the detailed formation and the FAQ in the user manual of the FBI610x.

Find the manual for free download under www.tcsag.de

Please send your questions and inquiries to

[email protected]

Headquarters

TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin

Tel.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911, www.tcsag.de

TCS TürControlSysteme AG, TCS Hotline Germany: [email protected] www.tcsag.de

Subject to technical changes.

PI_FBI610x_uk 1 A