red lion G315C manual
Add to my manuals8 Pages
Red Lion G315C is a powerful graphic color LCD operator interface terminal with TFT XGA display and touchscreen. It's configured using Crimson software (version 2.0 or later) and has up to 6 RS-232/422/485 communications ports. With a 10 BASE T/100 BASE-TX Ethernet port that supports multiple protocols simultaneously, a built-in web server, and an FTP server/client, the G315C offers extensive connectivity options. It also features a USB device port for configuration downloads and data transfers, and a CompactFlash® socket for database/recipe storage and data logging.
advertisement
Bulletin No. G315C2-D
Drawing No. LP0820
Released 11/14
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839 www.redlion.net
MODEL G315C2 – GRAPHIC COLOR LCD OPERATOR INTERFACE TERMINAL
WITH TFT XGA DISPLAY AND TOUCHSCREEN
CONFIGURED USING CRIMSON
(VERSION 2.0 OR LATER)
® SOFTWARE
C
UL
US LISTED
43NH
PROCESS CONTROL EQUIPMENT
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
UP TO 6 RS-232/422/485 COMMUNICATIONS PORTS
(2 RS-232 AND 2 RS-422/485 ON BOARD, 1 RS-232 AND 1
RS422/485 ON OPTIONAL COMMUNICATIONS CARD)
10 BASE T/100 BASE-TX ETHERNET PORT SUPPORTS MULTIPLE
PROTOCOLS SIMULTANEOUSLY (2nd ETHERNET PORT OPTIONAL)
BUILT-IN WEB SERVER AND FTP SERVER/CLIENT
USB DEVICE PORT TO DOWNLOAD THE UNIT’S CONFIGURATION
FROM A PC OR FOR DATA TRANSFERS TO A PC
UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE MEMORY
(64 MBYTE FLASH)
COMPACTFLASH ® SOCKET FOR DATABASE/RECIPE STORAGE
AND DATA LOGGING
15-INCH TFT ACTIVE MATRIX 32K COLOR XGA 1024 X 768 PIXEL
LCD WITH LED BACKLIGHT
10-BUTTON KEYPAD FOR ON-SCREEN MENUS
THREE FRONT PANEL LED INDICATORS
POWERED BY 24 VDC ±20% SUPPLY
RESISTIVE ANALOG TOUCHSCREEN
GENERAL DESCRIPTION
The G315C Operator Interface combines powerful features normally found only in PC-based HMIs, with the reliability of a dedicated operating system. It is built around a high performance core with integrated features, allowing it to provide SCADA-like functionality at a fraction of the cost.
The G315C is able to act as a multiple protocol converter using four highspeed RS232/422/485 communications ports and an Ethernet 10/100 Base-TX port. The Ethernet port supports up to four protocols simultaneously, allowing dissimilar Ethernet based products to communicate with one another.
The G315C’s USB port allows fast downloads of configuration files and access to trending and data logging. A CompactFlash socket is provided so that standard ComplactFlash cards can be used to collect your trending and data logging information as well as to store configuration files. The built-in web server allows processes to be controlled remotely.
The G315C’s large, high-resolution display allows users to easily view and enter information. Data can be manipulated through the touchscreen and/or the
10-button keypad.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the controller.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2
CAUTION: Risk of Danger.
Read complete instructions prior to installation and operation of the unit.
CompactFlash is a registered trademark of CompactFlash Association.
CONTENTS OF PACKAGE
- G315C2 Operator Interface.
- Panel gasket.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.
ORDERING INFORMATION
MODEL NO.
DESCRIPTION
15" TFT XGA Display Operator Interface (indoor),
USB Host
G315C2
G3CF
G3RS
G3CN
G3DN
CANopen Optional Communication Card
DeviceNet Option Card With Isolated High Speed
Communications Ports
G3GSM GSM/GPRS Modem Option Card 3
G3PBDP Profibus DP Optional Communication Card
SFCRM2 Crimson 2.0 2
RS-232 Programming Cable
CBL
DR
15" TFT XGA Display Operator Interface (indoor),
Dual Ethernet, USB Host
CompactFlash Card 6
RS232/485 Optional Communication Card
USB Cable
Communications Cables 1
DIN Rail Mountable Adapter Products 4
Replacement Battery 5
PART NUMBER
G315C210
G315C230
G3CFxxxx
G3RS0000
G3CN0000
G3DN0000
G3GSM000
G3PBDP00
SFCRM200
CBLPROG0
CBLUSB00
CBLxxxxx
DRxxxxxx
BNL20000
1 Contact your Red Lion distributor or visit our website for complete selection.
2 Use this part number to purchase Crimson on CD with a printed manual, USB cable, and RS-232 cable. Otherwise, download for free from
3 www.redlion.net.
Antenna (G3QANT00) is NOT included with the card. Must be purchased
4 separately if needed.
Red Lion offers RJ modular jack adapters. Refer to the DR literature for
5 complete details.
Battery type is lithium coin type CR2025.
6 Industrial grade two million write cycles. SMART Modular Technologies model SG9CF (UL Listed Directory Category NWGQ).
1
S
pecificationS
1. POWER REQUIREMENTS:
Must use a Class 2 circuit according to National Electrical Code (NEC),
NFPA-70 or Canadian Electrical Code (CEC), Part I, C22.1 or a Limited
Power Supply (LPS) according to IEC 60950-1 or Limited-energy circuit according to IEC 61010-1.
Power connection via removable three position terminal block.
Supply Voltage:
Typical Power 1 :
Maximum Power 2
+24 VDC ±20%
20 W
: 30 W
Notes:
1. Typical power with +24 VDC, RS232/485 communications, Ethernet communications, CompactFlash card installed, flash drive installed in one
USB Host port, and display at full brightness.
2. Maximum power is consumed when all features and comm ports are used at the same time. Refer to “Power Supply Requirements” under
“Installing and Powering the G315C.”
3. The G315C’s circuit common is not connected to the enclosure of the unit. See “Connecting to Earth Ground” in the section “Installing and
Powering the G315C.”
4. Read “Power Supply Requirements” in the section “Installing and
Powering the G315C” for additional power supply information.
2. BATTERY: Lithium coin cell. Typical lifetime of 10 years.
3. LCD DISPLAY:
SIZE
TYPE
COLORS
PIXELS
BRIGHTNESS
LED BACKLIGHT LIFE*
15-inch
TFT
32K
1024 X 768
600 cd/m 2
50,000 HR TYP.
*Lifetime at room temperature. Refer to “Display” in “Software/Unit Operation”
4. 10-KEY KEYPAD: for on-screen menus.
5. TOUCHSCREEN: Resistive analog
6. MEMORY:
On Board User Memory: 64 Mbyte of non-volatile Flash memory.
Memory Card: CompactFlash Type II slot for Type I and Type II
CompactFlash cards.
7. COMMUNICATIONS:
USB Device Port: Adheres to USB 2.0 Specification supporting high speed and full speed via Type B connection.
WARNING - DO NOT CONNECT OR DISCONNECT CABLES WHILE
POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON-
HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND DIAGNOSTICS
AND IS NOT INTENDED FOR PERMANENT CONNECTION.
USB Host Ports: Comply with Universal Serial Bus Specification Rev 2.0.
Support data transfers at full-speed. Hardware over current protected (0.5
A max per port).
Serial Ports: Format and Baud Rates for each port are individually software programmable up to 115,200 baud.
PGM Port: RS232 port via RJ12.
COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12.
DH485 TXEN: Transmit enable; open collector, V
OH
V
OL
= 15 VDC,
= 0.5 V @ 25 mA max.
Note: For additional information on the communications or signal common and connections to earth ground please see the “Connecting to
Earth Ground” in the section “Installing and Powering the G315C.”
Port to port isolation: 500 Vrms for 1 minutes signal isolation : 50V
Ethernet Port: 10 BASE-T / 100 BASE-TX
RJ45 jack is wired as a NIC (Network Interface Card).
Isolation from Ethernet network to G3 operator interface: 1500 Vrms
8. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50 °C
Storage Temperature Range: -20 to 70 °C
Operating and Storage Humidity: 80% maximum relative humidity (noncondensing) from 0 to 50°C.
Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g.
Shock to IEC 68-2-27: Operational 35 g.
Altitude: Up to 2000 meters.
9. CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A
Safety requirements for electrical equipment for measurement, control, and laboratory use:
EN 61010-1: General Requirements
RoHS Compliant
UL Listed: File #E179259
UL Hazardous: File #E245515
Type 4X Indoor Enclosure rating (Face only)
IP66 Enclosure rating (Face only)
10. CONNECTIONS: Compression cage-clamp terminal block.
Wire Gage: 12-22 AWG copper wire
Torque: 5-7 inch-pounds (56-79 N-cm)
11. CONSTRUCTION: Steel rear metal enclosure with Type 4X/IP66 aluminum front plate for indoor use only when correctly fitted with the gasket provided.
Installation Category II, Pollution Degree 2.
12. MOUNTING REQUIREMENTS: Maximum panel thickness is 0.25" (6.3 mm). For Type 4X/IP66 sealing, a steel panel with a minimum thickness of
0.125" (3.17 mm) is recommended.
Maximum Mounting Stud Torque: 17 inch-pounds (1.92 N-m)
13. WEIGHT: 11.41 lbs (5.17 Kg)
DIMENSIONS In inches (mm)
16.00 (406.4)
.28
(7.1)
2.8
(71.5)
13.00
(330.2)
14.59 (370.6)
11.59
(294.4)
PROTECTIVE EARTH GROUND
2
i
nStalling and
p
owering the
g315c
MOUNTING INSTRUCTIONS
This operator interface is designed for through-panel mounting. A panel cutout diagram and a template are provided. Care should be taken to remove any loose material from the mounting cut-out to prevent that material from falling into the operator interface during installation. A gasket is provided to enable sealing to Type 4X/IP66 specification. Install the 22 kep nuts provided and tighten evenly for uniform gasket compression.
Note: Tightening the kep nuts beyond a maximum of 17 inch-pounds (1.92
N-m) may cause damage to the front panel.
15.425 (391.8)
10.283 (261.2)
5.142 (130.6) 22X ∅.188
(∅4.8)
CONNECTING TO EARTH GROUND
Each G315C has a chassis ground terminal on the back of the unit. Your unit should be connected to earth ground.
The chassis ground is not connected to signal common of the unit.
Maintaining isolation between earth ground and signal common is not required to operate your unit. But, other equipment connected to this unit may require isolation between signal common and earth ground. To maintain isolation between signal common and earth ground care must be taken when connections
are made to the unit. For example, a power supply with isolation between its signal common and earth ground must be used. Also, plugging in a USB cable may connect signal common and earth ground.
1
1 USB’s shield may be connected to earth ground at the host. USB’s shield in turn may also be connected to signal common.
11.720
(297.7)
14.720 (373.9)
All tolerances ±0.010" (±0.25 mm).
2.485
(63.1)
7.455
(189.4)
12.425
(315.6)
ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING
DIVISION 2 WIRING METHODS AS SPECIFIED IN THE NATIONAL
ELECTRICAL CODE, NFPA 70 FOR INSTALLATION WITHIN THE
UNITED STATES, OR AS SPECIFIED IN THE CANADIAN
ELECTRICAL CODE FOR INSTALLATION IN CANADA.
POWER SUPPLY REQUIREMENTS
The G315C requires a 24 VDC power supply. Your unit may draw considerably less than the maximum rated power depending upon the options being used. As additional features are used your unit will draw increasing amounts of power. Items that could cause increases in current are additional communications, optional communications card, CompactFlash card, and other features programmed through Crimson.
In any case, it is very important that the power supply is mounted correctly if the unit is to operate reliably. Please take care to observe the following points:
– The power supply must be mounted close to the unit, with usually not more than 6 feet (1.8 m) of cable between the supply and the operator interface. Ideally, the shortest length possible should be used.
– The wire used to connect the operator interface’s power supply should be at least 22-gage wire. If a longer cable run is used, a heavier gage wire should be used. The routing of the cable should be kept away from large contactors, inverters, and other devices which may generate significant electrical noise.
– A power supply with an NEC Class 2 or Limited Power Source (LPS) and SELV rating is to be used. This type of power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults. SELV is an acronym for
“safety extra-low voltage.” Safety extra-low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault, such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred.
BLOCK DIAGRAM
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA
IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.
24VDC
+
-
POWER
SUPPLY
USB DEVICE
PROGRAMMING
A
A
ISOLATED
RS485
PORT A
ISOLATED
RS232
PORT A
PGM PORT
HOST A
B C A
ISOLATED
RS485
PORT B
D
ISOLATED
ETHERNET
F
ISOLATED
RS232
PORT B
E
ISOLATED
AUXILIARY
ETHERNET
G
HOST B
A
3
i
nStalling
a
n
o
ption
c
ard
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED
AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.
Each option card comes with a cable for communications and three screws for attaching the option card to the G3’s main board.
To install the option card, remove all power and I/O communications cables from the unit and remove the rear cover.
Connect the cable from the option card to the connector on the main board. Be sure both ends of the cable are firmly seated into their appropriate connector housings. Use the three screws provided to mount the option card to the main board as shown in
Figure 1.
Carefully replace the rear cover by reversing the instructions for removing the rear cover.
TYPICAL EXPANSION CARD INSTALLATION
Figure 1
c
ommunicating
w
ith the
g315c
CONFIGURING A G315C
The G315C is configured using Crimson ® software. Crimson is available as a free download from Red Lion’s website, or it can be purchased on CD. Updates to Crimson for new features and drivers are posted on the website as they become available. By configuring the G315C using the latest version of Crimson, you are assured that your unit has the most up to date feature set. Crimson software can configure the G315C through the RS232 PGM port, USB port, Ethernet port, or
CompactFlash.
The USB port is connected using a standard USB cable with a Type B connector. The driver needed to use the USB port will be installed with Crimson.
The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer. If you choose to make your own cable, use the “G315C Port Pin Out Diagram” for wiring information.
The CompactFlash can be used to program a G3 by placing a configuration file and firmware on the CompactFlash card. The card is then inserted into the target
G3, and the G3 is then powered up. Refer to the Crimson literature for more information on the proper names and locations of the files.
CABLES AND DRIVERS
Red Lion has a wide range of cables and drivers for use with many different communication types. A list of these drivers and cables along with pin outs is available from Red Lion’s website. New cables and drivers are added on a regular basis. If making your own cable, refer to the “G315C Port Pin Outs” for wiring information.
ETHERNET COMMUNICATIONS
Ethernet communications can be established at either 10 BASE-T or 100
BASE-TX. The G315C unit’s RJ45 jack is wired as a NIC (Network Interface
Card). For example, when wiring to a hub or switch use a straight-through cable, but when connecting to another NIC use a crossover cable.
The Ethernet connector contains two LEDs. A yellow LED in the upper right, and a bi-color green/amber LED in the upper left. The LEDs represent the following statuses:
USB, DATA TRANSFERS FROM THE
COMPACTFLASH CARD
WARNING - DO NOT CONNECT OR DISCONNECT CABLES
WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE
NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND
DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT
CONNECTION.
LED COLOR
YELLOW solid
YELLOW flashing
GREEN
AMBER
DESCRIPTION
Link established.
Data being transferred.
10 BASE-T Communications
100 BASE-TX Communications
On the rear of each unit is a unique 12-digit MAC address and a block for marking the unit with an IP address. Refer to the Crimson manual and Red
Lion’s website for additional information on Ethernet communications.
In order to transfer data from the CompactFlash card via the USB port, a driver must be installed on your computer. This driver is installed with Crimson and is located in the folder C:\Program Files\Red Lion Controls\Crimson 2.0\Device\ after
Crimson is installed. This may have already been accomplished if your G315C was configured using the USB port.
Once the driver is installed, connect the G315C to your PC with a USB cable, and follow “Mounting the CompactFlash” instructions in the Crimson 2 user manual.
4
w
iring the
g315c
G315C PORT PIN OUTS
EARTH GROUND
TxEN Rx Tx COMM COMM
ETHERNET
(NIC)
AUXILIARY
ETHERNET
(NIC)
PORT B
PORT A
USB
HOST
USB
TYPE B
POWER
CONNECTOR
RS485
PORT B
RS232
PORT B
RS485
PORT A
RS232
PORT A
PGM PORT
RS232 PORTS
The G315C has two isolated RS232 ports. The port marked “RS232/PORT A/
PGM PORT” may be used for programming as well as communications, while the port marked RS232/PORT B may only be used for communications.
Both ports can be used for either master or slave protocols.
RS232 CONNECTIONS
6 RTS
5 Tx
4 GND
3 GND
2 Rx
RS422/485 COMMS PORT
The G315C has two isolated RS422/485 ports. These ports can be configured to act as either RS422 or RS485.
RS422/485 4-WIRE
CONNECTIONS
5V
130K 7
1
TxB
TX
130K
8
2
TxA
RS485 2-WIRE
CONNECTIONS
5V
TX/RX
130K
130K
7
1
TxB
8
2
TxA
5 TxEN (OC) 5 TxEN (OC)
6 GND
RX
5V
130K
130K
4 RxB
3 RxA
6 GND
1 CTS
Note: All Red Lion devices connect A to A and B to B, except for Paradigm devices. Refer to www.redlion.net for additional information.
5
Examples of RS485 2-Wire Connections
G3: RJ45
5
6
1
2
G3 to Red Lion RJ11 (CBLRLC00)
DLC, IAMS, ITMS, PAXCDC4C
Name
TxEN
COM
TxB
TxA
Connections
RLC: RJ11
2
3
5
4
Name
TxEN
COM
B-
A+
G3
1,4
4,1
2,3
3,2
5
6
7
8
G3 to Modular Controller (CBLRLC05)
Name
TxB
RxB
TxA
RxA
TxEN
COM
TxB
TxA
Connections
Modular Controller
1,4
4,1
2,3
3,2
5
6
7
8
Name
TxB
RxB
TxA
RxA
TxEN
COM
TxB
TxA
DH485 Connections
The G315C’s RS422/485 COMMS port can also be used for Allen Bradley
DH485 communications.
WARNING: DO NOT use a standard DH485 cable to connect this port to Allen
Bradley equipment. A cable and wiring diagram are available from Red Lion.
RJ45: RLC
1
2
3, 8
4, 7
5
6
4, 7
3, 8
G3 to AB SLC 500 (CBLAB003)
Name
TxB
TxA
RxA
RxB
TxEN
COMM
TxB
TxA
Connections
RJ45: A-B
1
-
2
-
5
-
-
4
Name
A
B
24V
COMM
TxEN
SHIELD
COMM
24V
S
oftware
/u
nit
o
peration
CRIMSON ® SOFTWARE
Crimson ® software is available as a free download from Red Lion’s website or it can be purchased on a CD, see “Ordering Information” for part number. The latest version of the software is always available from the website, and updating your copy is free.
DISPLAY
This operator interface uses a liquid crystal display (LCD) for displaying text and graphics. The display utilizes an LED backlight for lighting the display. The backlight can be dimmed for low light conditions.
The LED backlight has a limited lifetime. Backlight lifetime is based upon the amount of time the display is turned on at full intensity. Turning the backlight off when the display is not in use can extend the lifetime of your backlight. This can be accomplished through the Crimson software when configuring your unit.
KEYPAD
The G315C keypad consists of ten keys that can be used for on-screen menus.
TOUCHSCREEN
This operator interface utilizes a resistive analog touchscreen for user input.
The unit will only produce an audible tone (beep) when a touch on an active touchscreen cell is sensed. The touchscreen is fully functional as soon as the operator interface is initialized, and can be operated with gloved hands.
TROUBLESHOOTING YOUR G315C
If for any reason you have trouble operating, connecting, or simply have questions concerning your new G315C, contact Red Lion’s technical support.
For contact information, refer to the back page of this bulletin for phone and fax numbers.
EMAIL: [email protected]
Web Site: http://www.redlion.net
General Troubleshooting Tech Note: http://www.redlion.net/TechNotes/TN0135.html
FRONT PANEL LEDS
There are three front panel LEDs. Shown below is the default status of the LEDs.
LED INDICATION
GREEN (TOP, LABELED “PWR”)
FLASHING Unit is in the boot loader, no valid configuration is loaded.
1
STEADY Unit is powered and running an application.
YELLOW (MIDDLE)
OFF No CompactFlash card is present.
STEADY Valid CompactFlash card present.
FLASHING
RAPIDLY
CompactFlash card being checked.
FLICKERING
Unit is writing to the CompactFlash, either because it is
storing data, or because the PC connected via the USB port
has locked the drive.
2
FLASHING
SLOWLY Incorrectly formatted CompactFlash card present.
GREEN (BOTTOM)
FLASHING A tag is in an alarm state.
STEADY Valid configuration is loaded and there are no alarms present.
1. The operator interface is shipped without a configuration. After downloading a configuration, if the light remains in the flashing state continuously, try cycling power. If the LED still continues to flash, try downloading a configuration again.
2. Do not turn off power to the unit while this light is flickering. The unit writes data in two minute intervals. Later Microsoft operating systems will not lock the drive unless they need to write data; Windows 98 may lock the drive any time it is mounted, thereby interfering with logging. Refer to
“Mounting the CompactFlash” in the Crimson 2 User Manual.
6
BATTERY & TIME KEEPING
WARNING - EXPLOSION HAZARD - THE AREA MUST BE
KNOWN TO BE NON-HAZARDOUS BEFORE SERVICING/
REPLACING THE UNIT AND BEFORE INSTALLING OR
REMOVING I/O WIRING AND BATTERY.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED
AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.
CAUTION: The circuit board contains static sensitive components.
Before handling the operator interface without the rear cover attached, discharge static charges from your body by touching a grounded bare metal object. Ideally, handle the operator interface at a static controlled clean workstation. Also, do not touch the surface areas of the circuit board. Dirt, oil, or other contaminants may adversely affect circuit operation.
A battery is used to keep time when the unit is without power. Typical accuracy of the G315C time keeping is less than one minute per month drift. The battery of a G315C unit does not affect the unit’s memory, all configurations and data is stored in non-volatile memory.
To change the battery of a G315C, remove power, cabling, and then the rear cover of the unit. To remove the cover, remove the 16 screws on the rear of the unit. Then, by lifting the top side, hinge the cover, thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below. Install in the reverse manner.
Remove the old battery* from the holder and replace with the new battery.
Replace the rear cover, cables, and re-apply power. Using Crimson or the unit’s keypad, enter the correct time and date.
* Please note that the old battery must be disposed of in a manner that complies with your local waste regulations. Also, the battery must not be disposed of in fire, or in a manner whereby it may be damaged and its contents come into contact with human skin.
The battery used by the G315C is a lithium type CR2025.
WARNING - EXPLOSION HAZARD -
BATTERIES MUST ONLY BE CHANGED IN AN
AREA KNOWN TO BE NON-HAZARDOUS.
COVER PLATE
BATTERY
EXPANSION
CARD
7
o
ptional
f
eatureS and
a
cceSSorieS
COMPACTFLASH SOCKET
CompactFlash socket is a Type II socket that can accept either Type I or II cards. Use cards with a minimum of 4Mbytes and formatted to a maximum of
2 GB (see Note box below) with the G315C’s CompactFlash socket. Cards are available at most computer and office supply retailers.
CompactFlash can be used for configuration transfers, larger configurations, data logging, and trending.
OPTIONAL COMMUNICATION CARD
Red Lion offers optional communication cards for fieldbus communications.
These communication cards will allow your G315C to communicate with many of the popular fieldbus protocols.
Red Lion is also offering a communications card for additional RS232 and
RS422/485 communications. Visit Red Lion’s website for information and availability of these cards.
)
CompactFlash-
Insert Face Up
Note: Do not remove or insert the CompactFlash card while power is applied. Refer to
“Front Panel LEDs.”
Information stored on a CompactFlash card by a G315C can be read by a card reader attached to a PC. This information is stored in IBM (Windows compatible FAT16 file format.
® ) PC
NOTE
For reliable operation of this and other Red Lion products, one of the following brands of CompactFlash card must be used...
SimpleTech SMART ®
SanDisk ®
Modular
Silicon Systems
Not all of the above manufacturers offer CompactFlash cards recognized to
UL standards, which may be required for your application.
Although RLC products limit use of CompactFlash card memory to 2 GB, cards with a larger capacity can be used. They MUST be formatted to 2
GB and use the FAT 16 file system. It is recommended to format the CF card using the format utility from within Crimson.
LIMITED WARRANTY
The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety
Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty
Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.
Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls
Europe
Softwareweg 9
NL - 3821 BN Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
Red Lion Controls
India
201-B, 2nd Floor, Park Centra
Opp 32 Mile Stone, Sector-30
Gurgaon-122002 Haryana, India
Tel +91 984 487 0503
Red Lion Controls
China
Unit 302, XinAn Plaza
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113 3688
Fax +86 21 6113 3683
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project