ENGLISH
Quick start guide - Altistart 22
Preliminary information
Information below is designed to use for simple applications with 2-wire control mode and freewheel stop.
If you need more information, or for other applications, see the User manual on www.schneider-electric.com
. For a hard copy, contact your local sales Office or Schneider Electric representative.
Note:
DO NOT USE this guide for Altistart 22 connected inside the delta of the motor (it means Altistart 22 connected to the motor with delta connections in series with each motor windings). In this case, see User manual on www.schneider-electric.com
.
Read and understand these instructions before performing any procedure with this soft starter.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION AND ARC FLASH
Read and understand this manual before installing or operating the Altistart 22 starter. Installation, adjustment, repair, and maintenance must be performed by qualified personnel.
• The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all equipment.
• Many parts of this soft starter, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools.
• DO NOT touch unshielded components or terminal strip screw connections with voltage present.
• Before servicing the starter:
- Disconnect all power, including external control power that will be present.
- Place a “DO NOT TURN ON” label on all power disconnects.
- Lock all power disconnects in the open position.
• Before applying power section close the enclosure.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by
Schneider Electric for any consequences out of the use of this material.
Check the delivery of the soft starter
Remove Altistart 22 from the packaging and check that it has not been damaged.
WARNING
DAMAGED SOFT STARTER EQUIPMENT
Do not operate or install any soft starter or soft starter accessory that appears damaged.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Check that the soft starter reference on the nameplate is similar to the purchase order delivery note.
Write the soft starter model Reference: ATS22 ______
and Serial Number :___________________
Check the line voltage compatibility
Check that the line voltage is compatible with the supply range of the soft starter.
Line voltage __________ Volts Soft starter voltage range ______________ Volts
Control voltage _______ Volts Soft starter control voltage range _______ Volts
Mount the soft starter vertically
For a surrounding air temperature up to 40 °C (104°F) .
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION AND ARC FLASH
ATS22 soft starters are open devices and must be mounted in a suitable enclosure.
Failure to follow these instructions will result in death or serious injury.
For other thermal conditions, see user manual on www.schneider-electric.com
.
www.schneider-electric.com 1/4 S1A10388 - 08/2009
Connect the soft starter
For ATS22 ppp Q or ATS22 ppp S6
2-wire control, freewheel stop a) Connect Power:
- Wire the soft starter to the ground.
- Wire the soft starter to the line supply: 1/L1 – 3/L2 – 5/L3.
- Check that the motor voltage is compatible with the soft starter voltage.
- Wire the soft starter to the motor.
(1) Check the operating limits of the contact.
(2) Select a voltage transformer in accordance with the mains voltage.
b) Connect Control:
Check that the control supply
is 230V
for CL1 and CL2.
- Remove the red sticker which covers the CL1-CL2 terminals.
- Wire control supply: CL1 and CL2.
- Wire logical inputs: LI1 and LI2.
- Wire the relay: R2A and R2C.
Note: For additional information in order to size the protective and control devices, refer to the catalog or the user manual available on www.schneider-electric.com
www.schneider-electric.com 2/4 S1A10388 - 08/2009
Connect the soft starter
For ATS22 ppp S6U
2-wire control, freewheel stop a) Connect Power:
- Wire the soft starter to the ground.
- Wire the soft starter to the line supply: 1/L1 – 3/L2 – 5/L3.
- Check that the motor voltage is compatible with the soft starter voltage.
- Wire the soft starter to the motor.
(1) Check the operating limits of the contact.
(2) Select a voltage transformer in accordance with the mains voltage.
b) Connect Control:
Check that the control supply
is 110V
for CL1 and CL2.
- Remove the red sticker which covers the CL1-CL2 terminals.
- Wire control supply: CL1 and CL2.
- Wire logical inputs: LI1 and LI2.
- Wire the relay: R2A and R2C.
Note: For additional information in order to size the protective and control devices, refer to the catalog or the user manual available on www.schneider-electric.com
www.schneider-electric.com 3/4 S1A10388 - 08/2009
Power on the control
• Check that S3 is open.
• Switch on: Q1, Q2, Q3 and Q4.
• The soft starter displays nrdY.
Adjust
UIn
line voltage
• Push scroll down button to reach conF menu.
Adjust
In
motor rated current
•
• In conF menu
Push scroll down button to reach In parameter.
• See Nominal Motor Current on Motor Nameplate • Push scroll down button to reach UIn parameter.
• Set UIn to the main line voltage ac value, using scroll Up/down.
• Push button to validate the UIn value.
•
•
(Motor Full Load Amps) in STAR connection, note the “Amps” value.
Set In to this value using scroll Up/down.
Push button to validate the In value.
Apply power to the Altistart 22 and start the motor
• Close the enclosure.
• Push S2 button.
• The soft starter displays rdY .
• Close S3, the motor starts.
Factory settings
The Altistart 22 is factory configured for most standard applications. If the factory configuration is not suitable for your application, refer to
User manual on www.schneider-electric.com. Here is the list of writable parameters in an “easy start up” mode.
Menu Code Description Factory setting Customer setting conF
Configuration
ICL dLtA
UIn
In
Cod
LAC t90
ILt tLS
Soft starter rated current
Connection type (Line or delta)
Line voltage
Motor rated current
Setting lock
Advanced mode
Initial voltage
Current limit
Max start time
According to the soft starter rating
LInE
ATS22 pppQ range: 400 Vac
ATS22 pppS6-S6U ranges: 480 Vac
According to the soft starter rating nLoC (Not locked) oFF
30 % of input voltage
350 % of In
IS s
SEt
Adjustments
ACC dEC
Acceleration time
Deceleration time
ID s
FrEE (Freewheel)
EdC tHP
Final torque
Motor thermal protection
O
IO (IEC class 10) rdY : soft starter ready, when power and control voltage are present and the motor is not operating.
nrdY : when power is not supplied and control voltage is supplied or when power and control voltage are present with LI1 not connected and
LI2 present (run command).
Short-circuit rating and branch circuit protection
(use in place of Q1 shown on page 2 and 3)
Recommended fuse ratings for UL and CSA requirements. Components for use together in accordance with standard UL508
ATS22
Stand-alone product
Max. short circuit current rating (SCCR)
X
Branch circuit protection
Rating
Soft starter 208/600 V- 60 Hz (+10% -15%) - Standard rating.
ATS22D17ppp
ATS22D32ppp
ATS22D47ppp
ATS22D62ppp
ATS22D75ppp
ATS22D88ppp
ATS22C11ppp
ATS22C14ppp
ATS22C17ppp
ATS22C21ppp
ATS22C25ppp
ATS22C32ppp
ATS22C41ppp
ATS22C48ppp
ATS22C59ppp
5 kA
10 kA
18 kA
30 kA
Z1 (1)
AJT40
AJT70
AJT100
AJT125
AJT175
AJT200
AJT250
AJT300
AJT400
AJT500
AJT600
2 x AJT350
2 x AJT400
2 x AJT500
2 x AJT600
Z2
40 A
70 A
100 A
125 A
175 A
200 A
250 A
300 A
400 A
500 A
600 A
2 x 350 A
2 x 400 A
2 x 500 A
2 x 600 A
Suitable for use on a circuit capable of delivering not more than
___X____ rms symmetrical Amperes, 575 Volts maximum, when protected by ___Z 1____ with a maximum rating of___Z 2___.
(1) Ferraz Shawmut manufacturer.
www.schneider-electric.com 4/4 S1A10388 - 08/2009
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Quick start guide - Altistart 22
- 1 Preliminary information
- 1 Check the delivery of the soft starter
- 1 Check the line voltage compatibility
- 1 Mount the soft starter vertically
- 2 Connect the soft starter
- 3 Connect the soft starter
- 4 Power on the control
- 4 Adjust UIn line voltage
- 4 Adjust In motor rated current
- 4 Apply power to the Altistart 22 and start the motor
- 4 Factory settings
- 4 Short-circuit rating and branch circuit protection (use in place of Q1 shown on page 2 and 3)