Parflange ECO 25

Add to my manuals
32 Pages

advertisement

Parflange ECO 25 | Manualzz

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

Bulletin 4390 - ECO25 June 2015

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL

INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

Offer of Sale

The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the “Offer of Sale.”

2

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

Table of Contents

Features and Advantages ...................................................................................4

ECO 25 Specifications ........................................................................................5

Setup Instructions ...............................................................................................5

Tube End Preparation .........................................................................................6

90˚ Flanging Information for Seal-Lok Fittings ........................................... 7-13

37˚ Flaring Information for Triple-Lok Fittings .......................................... 14-20

Component Parts Breakdown .................................................................... 21-27

ECO 25 Guide Assembly ..............................................................................21

ECO 25 Flare/Flange Head Assembly .........................................................23

ECO 25 Die Holder Assembly ......................................................................25

ECO 25 Motor Assembly ..............................................................................27

Offer of Sale .......................................................................................................28

3

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

Features and Advantages

Easy to Operate

The ECO 25 is capable of flanging or flaring steel and stainless tubing with a few simple operations. And since each die has flanging tooling on one side and flaring tooling on the other, you only need one die to perform both functions. In addition, because of its adjustable tube stop, the ECO 25 does not require a different die for each wall thickness of tubing – just one die for each tube outside diameter.

Portable

The ECO 25 has handles on three sides of the machine, making moving it around the workplace an easy task. It can either be set on its rubber feet or, for a more permanent location, bolted to a work bench or cart.

90˚ Flanging

The ECO 25 is capable of completing 90° flanges on steel and stainless steel tubing from ¼” through 1½” outside diameters for use with O-ring Face Seal tube fittings, such as Parker Seal-Lok

.

Hydraulic Pump

The ECO 25 is easily operated using a hand hydraulic pump, allowing it to be utilized virtually anywhere.

37˚ Flaring

The ECO 25 is capable of completing 37° flares on steel and stainless steel tubing from ¼” through 1½” outside diameters for use with JIC 37˚ flared tube fittings, such as Parker Triple-Lok ® .

Hand Pump

4

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

ECO 25 Specifications

Height

Width

Depth

Weight

Electrical Requirements

Motor

Maximum Pump Flow

Max. # Flares/Flanges per day

Capacity (90° Flanging)

Steel Tubing

Stainless Steel Tubing

Capacity (37° Flaring)

Steel Tubing

Stainless Steel Tubing

20.5 in. (520 mm)

15 in. (381 mm)

20.5 in. (520 mm)

190 lbs. (86.4 kg)

110 Volt, 1 phase, 60Hz/20A

1.5 HP

20 in.

3

/min.

50

1 1/2" O.D. x .120 Wall (38mm O.D. x 4mm Wall)

1 1/2" O.D. x .120 Wall (38mm O.D. x 4mm Wall)

1 1/2" O.D. x .120 Wall (38mm O.D. x 4mm Wall)

1 1/2" O.D. x .120 Wall (38mm O.D. x 4mm Wall)

Setup Instructions

Step 1: ECO 25 Adapter

Ensure the ECO 25 Adapter (part number 6 F5OLO-S) is properly installed into the SAE straight thread port in the rear of the

ECO 25 cylinder.

Step 5: Hose Conversion Adapters

Install Hose Conversion Adapter #1 (part number 6 G6L-S) onto the 1/4" male NPT threaded end (smaller end) of the Hose

Assembly (part number 910133) using a pipe thread sealant.

Then, install Hose Conversion Adapter #2 (part number 6-6

G6L-S) onto the 3/8" male NPT end (larger end) of the Hose

Assembly using a pipe thread sealant..

Step 2: Hydraulic Pump Tee

Install the Hydraulic Pump Adapter (part number 6-6 FLO-S) into the NPT pipe thread port in the rear of the hand-hydraulic pump with a pipe thread sealant. Assemble the swivel end of the

Hydraulic Pump Tee (part number 6 R6LO-S) to the Hydraulic

Pump Adapter. Make sure the branch end of the Tee is oriented upward.

Step 6: Hose to Pump Tee Assembly

Assemble the swivel end of the Hose Conversion Adapter #2

(part number 6-6 G6L-S) to the remaining end of the Hydraulic

Pump Tee (part number 6 R6LO-S).

Step 3: Pressure Gauge Adapter

Step 7: Hose to ECO 25 Assembly

Assemble the Pressure Gauge Adapter (part number 6 G6L-S) onto the NPT Pipe Thread end of the pressure gauge (part number 900044) with a pipe thread sealant.

Assemble the swivel end of Hose Conversion Adapter #1

(part number 6 G6L-S) to the ECO 25 Adapter (part number 6

F5OLO-S).

Step 4: Pressure Gauge

Assemble the Pressure Gauge and Adapter assembly onto the branch end of the Hydraulic Pump Tee (part number 6 R6LO-S).

Make sure to orient the front of the gauge toward the front of the

ECO 25 so it may be seen during operation.

Step 8: Check for Leaks

Assuring all connections are properly tightened, operate the hydraulic pump and check for leaks.

5

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

Tube End Preparation

Tube end preparation is one of the most critical processes in obtaining an optimum seal of a flanged or flared tube end connection. Regardless of the tube material, similar guidelines for tube cut-off, deburring, and cleanliness can help assure the tube to fitting connection remains leak free.

Tube Cutting

• It is critical that the tube be cut squarely within +/- 1° in order to assure the proper tube to fitting connection. A tube end which is not cut squarely may result in a flange or flare which is not circular, potentially causing leakage.

• When cutting tube in preparation for flanging or flaring, a saw which utilizes a toothed blade is recommended. This type of tool will assure that the tube end is not hardened from excessive heat or cold working of material.

Recommended

Low speed Circular Saw, Hacksaw

Not Recommended

Rotary Tube Cutter, Abrasive Saw

Tube Deburring

• Deburring the inside and outside diameter of the tube end is necessary to assure the tube fits properly inside the flange or flare sleeve. In addition, proper deburring of the tube end is necessary to form a flanged or flared tube end which is free of imperfections that may create a leak path between the tube and fitting.

Improper Cut

Proper Cut

Samples of improper and proper cuts on steel tube

6

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

90˚ Flanging Information for Seal-Lok Fittings

Flanging Die Set, Inch Sizes

Tube O.D.

(in.)

1/4

3/8

1/2

5/8

3/4

1

1 1/4

1 1/2

Die Set

Part Number

M2504

M2506

M2508

M2510

M2512

M2516

M2520

M2524

Flanging Pin, Inch Sizes

0.083

0.095

0.109

0.120

0.134

0.065

0.083

0.095

0.120

0.049

0.065

0.083

0.095

0.109

0.120

0.065

Wall

Thickness

(in.)

0.028

0.035

0.049

0.035

0.049

0.065

0.035

0.049

0.065

0.083

0.095

0.049

0.065

0.083

0.095

0.109

0.120

0.134

0.065

0.083

0.095

0.109

0.120

1

1 1/4

1 1/4

1 1/4

1

1

1

1

3/4

3/4

3/4

1

5/8

3/4

3/4

3/4

1 1/4

1 1/4

1 1/4

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

5/8

5/8

5/8

5/8

1/2

1/2

1/2

1/2

Tube O.D.

(in.)

1/4

1/4

1/4

3/8

3/8

3/8

1/2

Flanging Pin

Steel Tube

B4004X028180

Flanging Pin

Stainless Tube

-

B4004X035180 B4004X035180SS

B4004X049180 B4004X049180SS

B4006X035180 B4006X035180SS

B4006X049180 B4006X049180SS

B4006X065180 B4006X065180SS

B4008X035180 B4008X035180SS

B4008X049180 B4008X049180SS

B4008X065180 B4008X065180SS

B4008X083180 B4008X083180SS

B4008X095181 B4008X095180SS

B4010X049180 B4010X049180SS

B4010X065180 B4010X065180SS

B4010X083180 B4010X083180SS

B4010X095180 B4010X095180SS

B4010X120180 -

B4012X049180 B4012X049180SS

B4012X065180 B4012X065180SS

B4012X083180 B4012X083180SS

B4012X095180 B4012X095180SS

B4012X109180 B4012X109180SS

B4012X120180 B4012X120180SS

B4016X065180 B4016X065180SS

B4016X083180 B4016X083180SS

B4016X095180 B4016X095180SS

B4016X109180 B4016X109180SS

B4016X120180 B4016X120180SS

B4016X134180

B4020X065180 -

B4020X083180 B4020X083180SS

B4020X095180 B4020X095180SS

B4020X109180 B4020X109180SS

B4020X120180 B4020X120180SS

B4020X134180 -

B4024X065180

B4024X083180

-

-

B4024X095180 B4024X095180SS

B4024X109180 B4024X109180SS

B4024X120180 B4024X120180SS

7

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

90˚ Flanging Information for Seal-Lok Fittings

Parflange ECO 25 Dial Settings and Pressures for 90˚ Flanging

Steel Tube

0072

0064

0059

0055

0050

0081

0075

0072

0068

0081

0075

0075

0064

0059

0055

0074

Tube Stop

Setting

0088

0086

0077

0095

0089

0082

0099

0094

0093

0088

0079

0088

0083

0075

0071

0067

0064

0059

0070

0065

0061

0056

0053

0.083

0.095

0.109

0.120

0.134

0.065

0.083

0.095

0.120

0.049

0.065

0.083

0.095

0.109

0.120

0.065

Wall

Thickness

(in.)

0.028

0.035

0.049

0.035

0.049

0.065

0.035

0.049

0.065

0.083

0.095

0.049

0.065

0.083

0.095

0.109

0.120

0.134

0.065

0.083

0.095

0.109

0.120

1

1 1/4

1 1/4

1 1/4

1

1

1

1

3/4

3/4

3/4

1

5/8

3/4

3/4

3/4

1 1/4

1 1/4

1 1/4

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

5/8

5/8

5/8

5/8

1/2

1/2

1/2

1/2

Tube O.D.

(in.)

1/4

1/4

1/4

3/8

3/8

3/8

1/2

0198

0199

0201

0200

0201

0194

0199

0199

0208

0197

0200

0202

0200

0199

0198

0196

Head Stop

Setting

0199

0196

0198

0200

0202

0201

0203

0195

0204

0204

0204

0195

0200

0199

0197

0196

0199

0200

0192

0196

0197

0194

0198

3000

3200

3400

4000

4500

3600

4000

4000

4800

1500

2000

3000

3000

3000

3000

3000

4000

4800

5000

2000

3600

4600

4600

5000

1500

1600

2000

2200

1600

2000

2600

2000

Flanging

Pressure

(psi)

1000

1000

1500

1000

1600

2000

1000

Stainless Steel Tube

5000

5500

6500

6500

-

-

6500

6000

-

4600

5600

5000

5000

6000

6500

4500

6000

6500

-

-

-

6500

6500

6000

3000

3500

3600

3600

3000

3000

5000

5000

Flanging

Pressure

(psi)

-

2000

3000

2500

2500

3000

2000

0063

0064

0047

0045

-

-

0063

0062

-

0077

0067

0064

0059

0045

0050

0065

Tube Stop

Setting

-

0086

0075

0082

0084

0082

0098

0094

0088

0078

0073

0078

0078

0072

0066

0058

0045

-

-

-

0031

0044

0038

0204

0199

0201

0201

-

-

0203

0202

-

0202

0206

0200

0203

0203

0203

0200

Head Stop

Setting

-

0201

0208

0205

0206

0206

0202

0198

0205

0201

0200

0198

0201

0208

0206

0201

0198

-

-

-

0190

0192

0187

8

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

90˚ Flanging Information for Seal-Lok Fittings

Components Required

• Dual-Function Flare/Flange Die Set (contains tooling for both

Flanging and Flaring)

See chart page 7

• Flanging Pin specific to Tube O.D., Wall Thickness, and Tube

Material

See chart page 7

• LB-2000 Lubricant

Dual Function Die Set

Flanging Pin

LB-2000 Lubricant

ECO 25 Operating Instructions for 90˚ Flanging

for Seal-Lok FIttings

Step 1: Measure the tube O.D. and wall thickness for proper die and pin selection.

Step 2: Select the die set and flanging pin matching the tube

O.D., wall thickness and material of your tube from the charts on page 7. The die set is stamped with the tube

O.D. and the pin is stamped with both the tube O.D. and wall thickness (and material if flanging stainless steel tube).

Step 3: Open the swing arm to expose die cavity and main spindle head.

9

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

90˚ Flanging Information for Seal-Lok Fittings

Step 4: Raise the tube stop and install the flanging pin into the main spindle head of the machine. Be sure to lower the tube stop to its original position after inserting the pin.

Step 5: Using the LB-2000 lubricant, adequately lubricate the flanging pin as well as the inside diameter of the tube end.

It is very important to lubricate the Flanging

Pin and Inside Diameter of the tube end prior to

each flanging operation.

Step 6: Insert the bottom half of the die set (either die half can be used) into the die cavity of the machine using the keyways on either side to secure the die.

Ensure that the 90° Flange side of the die half is facing toward the main spindle head of the machine (away from the operator).

Step 7: Place a Parflange mechanical sleeve (part number

TPL) onto the end of the tube with the widest part of the sleeve facing the end of the tube you intend to flange.

Place the sleeve and tube assembly into the bottom half of the die set, ensuring the Parflange sleeve is placed into the corresponding cavity in the die half.

Step 8: Insert the top half of the die set into the die cavity on top of the other half, also ensuring that the 90° Flange side of the die half is facing toward the main spindle head of the machine.

Step 9: Set Tube Stop adjustment dial to recommended value for flanging the O.D., wall thickness and material of the tubing you are using (See Chart on page 8). Dial settings are recommendations only and may require adjustment to obtain desired results.

10

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

90˚ Flanging Information for Seal-Lok Fittings

Step 10: Set Head Stop adjustment dial to recommended value for flanging the O.D., wall thickness and material of the tubing you are using (See Chart on page 8). Dial settings are recommendations only and may require adjustment to obtain desired results.

Step 11: Close swing arm against shoulder bolt.

Step 12: While keeping tube end against tube stop, rotate clamp vise arm clockwise and securely clamp tube in die set. Be sure to properly support long tubes during the clamping and flanging process.

Step 13: Obtain the recommended flanging pressure for the

O.D., wall thickness, and tube material you are using from the chart on page 8.

Step 14: Press and release green start button on front of machine to start rotation of main spindle head. If head does not rotate upon activation of motor, check electrical connections and retry. Be sure to use an electrical outlet with 110V/20A power.

Step 15: Ensure the tube is held in position and slowly actuate the hydraulic hand pump. The flanging pin will come forward and the tube stop will automatically rise up and away from the tube. The pressure gauge will show a rapid rise in pressure as the pin engages the tube end and flanges the tube.

11

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

90˚ Flanging Information for Seal-Lok Fittings

Step 16: When the pressure gauge reaches the recommended flanging pressure from Step 13, de-energize the hydraulic power supply. This will allow the flanging pin and spindle head to retract to their original position.

Step 17: Press the red stop button on the front of the machine to stop rotation of the main spindle head.

Step 18: Rotate clamp vise handle counter-clockwise to loosen clamp from die set and tube and open swing arm to expose die halves.

Step 19: Remove the top half of the die set from the die cavity and set aside.

Step 20: Remove flanged tube from bottom half of die.

12

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

90˚ Flanging Information for Seal-Lok Fittings

Step 21: Inspect flange to ensure proper surface finish. Measure the flange diameter and compare to values in chart below.

Adjusting the ECO 25 to compensate for over/undersized flange diameters

If the flange diameter of your ECO 25 tube assembly is not within the diameter specifications listed, please complete the following steps:

• First, check to make sure that the correct flanging pin and die set are being used for the outside diameter, wall thickness, and material tubing you are using. Keep in mind that each

Die Set can be used with every wall thickness of that size tubing and also with both carbon and stainless steel tubing.

However, the flanging pins are specific to the outside diameter, wall thickness, and material of the tubing.

• Once the tooling and tubing have been verified, the correct method of increasing or decreasing the diameter of the tube flange is to alter the Head Stop adjustment dial (do not change the Tube Stop adjustment dial setting).

• To increase the diameter of a tube flange, adjust the Head Stop adjustment dial

Clockwise (dial setting number will increase) a small amount and repeat the flanging process. If the desired result is not achieved, repeat adjustment process as needed until the proper sized flange is made.

• To decrease the diameter of a tube flange, adjust the Head

Stop adjustment dial

Counter Clockwise (dial setting number will decrease) a small amount and repeat the flanging process.

If the desired result is not achieved, repeat adjustment process as needed until the proper sized flange is made.

Flange

Diameter

Inch

Tube O.D.

(in.)

1/4

3/8

1/2

5/8

3/4

1

1-1/4

1-1/2

90˚ Flange dimensions

Metric

Tube O.D.

(mm)

6

10

12

14, 15, 16

18, 20

22, 25

28, 30, 32

38

Flange

Diameter

(in.)

.478 / .502

.594 / .620

.719 / .745

.875 / .923

1.048 / 1.097

1.298 / 1.347

1.549 / 1.597

1.861 / 1.910

13

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

37˚ Flaring Information for Triple-Lok Fittings

Flaring Die Sets, Inch Sizes

Fitting

Dash Size

4

6

8

10

12

16

20

24

Tube

O.D.

(in.)

1/4

3/8

1/2

5/8

3/4

1

1 1/4

1 1/2

Die Set

Part Number

M2504

M2506

M2508

M2510

M2512

M2516

M2520

M2524

Flaring Pins, Inch Sizes

0.120

0.065

0.083

0.095

0.109

0.120

0.065

0.083

0.065

0.083

0.095

0.109

0.065

0.083

0.095

0.109

0.095

0.109

0.120

Wall

Thickness

(in.)

0.028

0.035

0.049

0.035

0.049

0.065

0.035

0.049

0.065

0.083

0.049

0.065

0.083

0.095

0.049

1

1 1/4

1 1/4

1 1/4

1 1/4

1 1/4

1 1/2

1 1/2

1

1

1

1

3/4

3/4

3/4

3/4

1 1/2

1 1/2

1 1/2

5/8

5/8

5/8

3/4

1/2

1/2

1/2

5/8

Tube O.D.

(in.)

1/4

1/4

1/4

3/8

3/8

3/8

1/2

B4012X065074

B4012X083074

B4012X095074

B4012X109074

B4016X065074

B4016X083074

B4016X095074

B4016X109074

B4016X120074

B4020X065074

B4020X083074

B4020X095074

B4020X109074

B4020X120074

B4024X065074

B4024X083074

B4024X095074

B4024X109074

B4024X120074

Flaring Pin

Part Number

B4004X028074

B4004X035074

B4004X049074

B4006X035074

B4006X049074

B4006X065074

B4008X035074

B4008X049074

B4008X065074

B4008X083074

B4010X049074

B4010X065074

B4010X083074

B4010X095074

B4012X049074

Note: Tooling suitable for 37˚ flaring of steel and stainless steel tube materials. One die covers each tube O.D., but a different pin is required for each tube wall thickness.

14

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

37˚ Flaring Information for Triple-Lok Fittings

Parflange ECO 25 Dial Settings and Pressures for 37˚ Flaring

Steel Tube

0.120

0.065

0.083

0.095

0.109

0.120

0.065

0.083

0.065

0.083

0.095

0.109

0.065

0.083

0.095

0.109

0.095

0.109

0.120

Wall

Thickness

(in.)

0.028

0.035

0.049

0.035

0.049

0.065

0.035

0.049

0.065

0.083

0.049

0.065

0.083

0.095

0.049

1

1 1/4

1 1/4

1 1/4

1 1/4

1 1/4

1 1/2

1 1/2

1

1

1

1

3/4

3/4

3/4

3/4

1 1/2

1 1/2

1 1/2

5/8

5/8

5/8

3/4

1/2

1/2

1/2

5/8

Tube O.D.

(in.)

1/4

1/4

1/4

3/8

3/8

3/8

1/2

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

Head Stop

Setting

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

Tube Stop

Setting

0150

0150

0150

0150

0150

0150

0150

3000

2500

2500

3000

3000

3500

2000

2000

1500

2000

2000

2000

1500

1500

1500

2000

2000

2500

2500

1000

1000

1000

1000

1500

2000

2000

1000

Flaring

Pressure

(psi)

1000

1000

1000

1000

1000

1000

1000

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

0150

Stainless Steel Tube

Flaring

Tube Stop

Setting

Head Stop

Setting

Pressure

(psi)

0150 0275 1000

0150

0150

0275

0275

1000

1500

0150

0150

0150

0150

0275

0275

0275

0275

1000

1500

1500

1500

0275

0275

0275

0275

0275

0275

0275

0275

1500

1500

1500

1500

2000

2000

2500

1500

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

0275

4000

2500

3000

3500

3500

3500

2000

2000

2000

2000

2500

2500

2000

2000

2500

3500

2500

3000

3000

15

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

37˚ Flaring Information for Triple-Lok Fittings

Components Required

• Dual-Function Flare/Flange Die Set (contains tooling for both

Flanging and Flaring)

See chart page 14

• Flaring Pin specific to Tube O.D. and Wall Thickness

See chart page 14

Dual Function Die Set

• LB-2000 Lubricant

Flaring Pin

LB-2000 Lubricant

ECO 25 Operating Instructions for 37˚ Flaring

for Triple-Lok FIttings

Step 1: Measure the tube O.D. and wall thickness for proper die and pin selection.

Step 2: Select the die set and flaring pin matching the tube

O.D. and wall thickness of your tube from the chart on page 7. The die set is stamped with the tube O.D. and the pin is stamped with both the tube O.D. and wall thickness.

Step 3: Open the swing arm to expose die cavity and main spindle head.

16

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

37˚ Flaring Information for Triple-Lok Fittings

Step 4: Raise the tube stop and install the flaring pin into the main spindle head of the machine. Be sure to lower the tube stop to its original position after inserting the pin.

Step 5: Using the LB-2000 lubricant, adequately lubricate the flaring pin as well as the inside diameter of the tube end.

It is very important to lubricate the Flaring Pin and Inside Diameter of the tube end prior to each

flaring operation.

Step 6: Insert the bottom half of the die set (either die half can be used) into the die cavity of the machine using the keyways on either side to secure the die.

Ensure that the 37° Flare side of the die half is facing toward the main spindle head of the machine (away from the operator).

Step 7: Insert the top half of the die set into the die cavity on top of the other half, also ensuring that the 37° Flare side of the die half is facing toward the main spindle head of the machine.

Step 8: Rotate the Tube Stop adjustment dial clockwise until it cannot be adjusted any further (dial should read approximately 0150). At this point, the tube stop should be in contact with the back side of the die set, but please ensure it is not pressing against the die set too tightly, as this can damage the machine. The aim is to line up the tube end flush with the back side of the die set.

This process will be the same for every size and wall thickness of tubing used.

Step 9: Rotate the Head Stop adjustment dial clockwise until it cannot be adjusted any further (dial should read approximately 0275 but it may be slightly higher or lower). The aim is to get the head stop out of the way of the spindle head travel, as it is not necessary for the flaring process. This process will be the same for every size and wall thickness of tubing used.

17

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

37˚ Flaring Information for Triple-Lok Fittings

Step 10: Insert the tube through the die set until it touches the tube stop. You may have to raise the upper die half slightly to allow the tube to fully insert through the die set.

Step 11: Close swing arm against shoulder bolt.

Step 12: While keeping the tube end against the tube stop, rotate clamp vise arm clockwise and securely clamp tube in die set. Be sure to properly support long tubes during the clamping and flaring process.

Step 13: Obtain the recommended flaring pressure for the O.D., wall thickness, and tube material you are using from the chart on page 15.

Step 14: Press and release green start button on front of machine to start rotation of main spindle head. If head does not rotate upon activation of motor, check electrical connections and retry. Be sure to use an electrical socket with 110V/20A power.

Step 15: Ensure the tube is held in position and energize the hydraulic power supply. The flaring pin will come forward and the tube stop will automatically rise up and away from the tube end. The pressure gauge will show a rapid rise as the pin engages the tube end and flares the tube.

18

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

37˚ Flaring Information for Triple-Lok Fittings

Step 16: When the pressure gauge reaches the recommended flaring pressure from Step 13, de-energize the hydraulic power supply. This will allow the flaring pin and spindle head to retract to their original position.

Step 17: Press the red stop button on the front of the machine to stop rotation of the main spindle head.

Step 18: Rotate clamp vise handle counter-clockwise to loosen clamp from die set and tube and open swing arm to expose die halves.

Step 19: Remove the top half of the die set from the die cavity and set aside.

Step 20: Remove flared tube from bottom half of die set

19

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

37˚ Flaring Information for Triple-Lok Fittings

Step 21: Inspect the flare to ensure proper surface finish. Measure the flare diameter and compare to values in chart below.

Adjusting the ECO 25 to compensate for over/undersized flare diameters

If the flare diameter of your ECO 25 tube assembly is not within the diameter specifications listed, please complete the following steps:

• First, check to make sure that the correct flaring pin and die set are being used for the outside diameter, wall thickness, and material tubing you are using. Keep in mind that each

Die Set can be used with every wall thickness of that size tubing and also with both carbon and stainless steel tubing.

However, the flaring pins are specific to the outside diameter and wall thickness of the tubing.

• Once the tooling and tubing have been verified, the correct method of increasing or decreasing the diameter of the tube flare is to alter the flaring pressure used during the flaring process.

• To increase the diameter of a tube flare, repeat the flaring process as before, but utilize a slightly higher flaring pressure than noted in the charge on page 15. Continue this process until the flare diameter is within the specifications listed to the right.

• To decrease the diameter of a tube flare, repeat the flaring process as before, but utilize a slightly lower flaring pressure than noted in the chart on page 15. Continue this process until the flare diameter is within the specifications listed to the right.

Inch

Tube O.D.

(in.)

Metric

Tube O.D.

(mm)

37° Flare

Diameter ØA

(in.)

1/4

5/16

3/8

6

8

10

.340/.360

.400/.430

.460/.490

1/2

5/8

3/4

1

1 1/4

1 1/2

12

15 & 16

18 & 20

25

.630/.660

.760/.790

.920/.950

1.170/1.200

30 & 32 1.480/1.510

38 1.700/1.730

37° Flare Dimensions

20

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

21

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

22

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

23

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

24

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

Component Parts Breakdown - ECO 25 Die Holder Assembly

5

25

24

13

12

10

15

18

4

23

2

1

9

20

14

21

16

8

19

25

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Component Parts Breakdown

ECO 25 Die Holder Assembly Parts List

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

8

14

15

16

9

10

12

13

18

19

20

21

23

24

25

Item

1

2

4

5

4

1

1

2

1

1

2

1

4

1

1

2

2

1

1

Qty.

1

2

1

2

Part Number

SK112411JW02_02

KEY GUIDE

SK112411JW01

SWING BOLTS

GUIDE RAIL BOLTS

POSITION INDICATOR

SK041712JW02

SK041712JW03

SK041712JW00

SK041712JW01

TUBE STOP SET SCREW

BUMPER FOOT

KEY GUIDE IDLER MOUNT BOLTS

THREADED BAR CLIP

STAR KNOB HANDLE

THREADED BAR - TUBE STOP

DIE VICE GRIP HANDLE

DIE VICE GRIP BOLT

BALL PLUNGER

Description

FRONT PLATE

5/16" X 5/16" X 3.138" LONG KEY STOCK

SWING

ALLOY STEEL SHOULDER SCREW, 3/4" SHOULDER DIAMETER,

1 1/4 L SHOULDER, 5/8-11 THREAD

1/2"-20 X 1 1/2" BLACK OXIDE ALLOY STEEL SOCKET CAP SCREW

GRADE 8

4 DIGIT POSITION INDICATOR

TUBE STOP GUIDE POST

TUBE STOP SLIDER NUT

TUBE STOP PLATE

TUBE STOP COLLAR

5-40 UNC-2A X 0.5" LONG SET SCREW

5/16" -18 X 2.125" HEIGHT

#6-32 X 5/8" BLACK OXIDE ALLOY STEEL SOCKET CAP SCREW

GRADE 8

9/16" EXTERNAL RETAINING RING

REFERENCE FASTENAL PN 11101409

TUBE STOP ADJUSTMENT SCREW

DIE VICE GRIP HANDLE

DIE VICE GRIP BOLT

REFERENCE CARRLANE PN CL-60-BP-3

26

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

Component Parts Breakdown - ECO 25 Motor Assembly

17

55

51

42

18

Component Parts Breakdown - ECO 25 Motor Assembly Parts List

Item

17

18

42

51

55

Qty.

1

1

1

4

3

Part Number

MOTOR

SK112211JW01_02

SMALL PULLEY

MOTOR MOUNT2GUIDE BOLTS

MOTOR, HEAD STOP MOUNT BOLTS

Description

NEMA 56 FRAME, 1.5 HP, 1725 RM, 115/230V, SINGLE PHASE 60 HZ

E-MOTOR

MOTOR PLATE

3/8" PITCH; L BELT SIZE; 1" BELT WIDTH; 14 TEETH; 1.671" PITCH

DIAMETER; 5/8" FINISHED BORE

1/2"-20 X 7/8" BLACK OXIDE ALLOY STEEL SOCKET CAP SCREW

GRADE 8

5/16"-24 X 1/2" BLACK OXIDE ALLOY STEEL SOCKET CAP SCREW

GRADE 8

27

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Offer of Sale

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

Offer of Sale

The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors (“Seller”) are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions. Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods, services or work described will be referred to as “Products”.

1. Terms and Conditions. ASeller’s willingness to offer Products, or accept an order for Products, to or from Buyer is subject to these Terms and Conditions or any newer version of the terms and conditions found on-line at www.parker.com/saleterms/. Seller objects to any contrary or additional terms or conditions of Buyer’s order or any other document issued by Buyer.

2. Price Adjustments; Payments. Prices stated on Seller’s quote or other documentation offered by Seller are valid for 30 days, and do not include any sales, use, or other taxes unless specifically stated. Unless otherwise specified by Seller, all prices are F.C.A. Seller’s facility (INCOTERMS

2010). Payment is subject to credit approval and is due 30 days from the date of invoice or such other term as required by Seller’s Credit Department, after which Buyer shall pay interest on any unpaid invoices at the rate of 1.5% per month or the maximum allowable rate under applicable law.

3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and Seller shall not be responsible for any damages resulting from any delay. Regardless of the manner of shipment, title to any products and risk of loss or damage shall pass to Buyer upon placement of the products with the shipment carrier at Seller’s facility. Unless otherwise stated, Seller may exercise its judgment in choosing the carrier and means of delivery. No deferment of shipment at Buyers’ request beyond the respective dates indicated will be made except on terms that will indemnify, defend and hold Seller harmless against all loss and additional expense. Buyer shall be responsible for any additional shipping charges incurred by Seller due to Buyer’s acts or omissions.

4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects in material or workmanship for a period of twelve months from the date of delivery to Buyer or 2,000 hours of normal use, whichever occurs first. The prices charged for Seller’s products are based upon the exclusive limited warranty stated above, and upon the following disclaimer:

DISCLAIMER OF WARRANTY: THIS WARRANTY

COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING

TO PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS

ALL OTHER WARRANTIES, EXPRESS AND IMPLIED, INCLUDING

DESIGN, MERCHANTABILITY AND FITNESS FOR A PARTICULAR

PURPOSE.

5. Claims; Commencement of Actions. Buyer shall promptly inspect all

Products upon delivery. No claims for shortages will be allowed unless reported to the Seller within 10 days of delivery. No other claims against

Seller will be allowed unless asserted in writing within 30 days after delivery. Buyer shall notify Seller of any alleged breach of warranty within

30 days after the date the defect is or should have been discovered by

Buyer. Any action based upon breach of this agreement or upon any other claim arising out of this sale (other than an action by Seller for an amount due on any invoice) must be commenced within 12 months from the date of the breach without regard to the date breach is discovered.

6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT

ITS OPTION, REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR

REFUND THE PURCHASE PRICE.

IN NO EVENT SHALL SELLER BE

LIABLE TO BUYER FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR

CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT

OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR

LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF, OR

FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED

WITHOUT SELLER’S WRITTEN CONSENT, EVEN IF SELLER HAS

BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR OTHER

LEGAL THEORY. IN NO EVENT SHALL SELLER’S LIABILITY UNDER

ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF

THE PRODUCTS.

7. User Responsibility. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and

Product and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application and follow applicable industry standards and Product information. If Seller provides Product or system options, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the Products or systems.

8. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confidential information or equipment furnished by Buyer or any other items which become Buyer’s property, will be considered obsolete and may be destroyed by Seller after two consecutive years have elapsed without Buyer ordering the items manufactured using such property.

Seller shall not be responsible for any loss or damage to such property while it is in Seller’s possession or control.

9. Special Tooling. A tooling charge may be imposed for any special tooling, including without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. Such special tooling shall be and remain Seller’s property notwithstanding payment of any charges by

Buyer. In no event will Buyer acquire any interest in apparatus belonging to Seller which is utilized in the manufacture of the Products, even if such apparatus has been specially converted or adapted for such manufacture and notwithstanding any charges paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or otherwise dispose of any special tooling or other property in its sole discretion at any time.

10. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise, Seller shall retain a security interest in the goods delivered and this agreement shall be deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems necessary to perfect its security interest.

11. Improper use and Indemnity. Buyer shall indemnify, defend, and hold

Seller harmless from any claim, liability, damages, lawsuits, and costs

(including attorney fees), whether for personal injury, property damage, patent, trademark or copyright infringement or any other claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out of: (a) improper selection, improper application or other misuse of Products purchased by Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product; or (d)

Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify Buyer under any circumstance except as otherwise provided.

12. Cancellations and Changes. Orders shall not be subject to cancellation or change by Buyer for any reason, except with Seller’s written consent and upon terms that will indemnify, defend and hold Seller harmless against all direct, incidental and consequential loss or damage. Seller may change product features, specifications, designs and availability with or without notice to Buyer.

13. Limitation on Assignment. Buyer may not assign its rights or obligations under this agreement without the prior written consent of Seller.

14. Force Majeure. Seller does not assume the risk and shall not be liable for delay or failure to perform any of Seller’s obligations by reason of circumstances beyond the reasonable control of Seller (hereinafter “Events of Force Majeure”). Events of Force Majeure shall include without limitation: accidents, strikes or labor disputes, acts of any government or government agency, acts of nature, delays or failures in delivery from carriers or suppliers, shortages of materials, or any other cause beyond

Seller’s reasonable control.

15. Waiver and Severability. Failure to enforce any provision of this agreement will not waive that provision nor will any such failure prejudice

Seller’s right to enforce that provision in the future. Invalidation of any provision of this agreement by legislation or other rule of law shall not invalidate any other provision herein. The remaining provisions of this agreement will remain in full force and effect.

16. Termination. Seller may terminate this agreement for any reason and at any time by giving Buyer thirty (30) days written notice of termination.

Seller may immediately terminate this agreement, in writing, if Buyer: (a) commits a breach of any provision of this agreement (b) appointments a trustee, receiver or custodian for all or any part of Buyer’s property (c) files a petition for relief in bankruptcy on its own behalf, or by a third party

(d) makes an assignment for the benefit of creditors, or (e) dissolves or liquidates all or a majority of its assets.

17. Governing Law. This agreement and the sale and delivery of all

Products hereunder shall be deemed to have taken place in and shall be governed and construed in accordance with the laws of the State of Ohio, as applicable to contracts executed and wholly performed therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and consents to the exclusive jurisdiction and venue of the courts of

Cuyahoga County, Ohio with respect to any dispute, controversy or claim arising out of or relating to this agreement.

28

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Offer of Sale

Offer of Sale

18. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets or similar rights except as provided in this Section. Seller will defend and indemnify Buyer against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense and will pay the cost of any settlement or damages awarded in an action brought against Buyer based on an allegation that a Product sold pursuant to this Agreement infringes the Intellectual Property Rights of a third party. Seller’s obligation to defend and indemnify Buyer is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of such allegations of infringement, and Seller having sole control over the defense of any allegations or actions including all negotiations for settlement or compromise. If a Product is subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller may, at its sole expense and option, procure for Buyer the right to continue using the

Product, replace or modify the Product so as to make it noninfringing, or offer to accept return of the Product and return the purchase price less a reasonable allowance for depreciation. Notwithstanding the foregoing,

Seller shall have no liability for claims of infringement based on information provided by Buyer, or directed to Products delivered hereunder for which the designs are specified in whole or part by Buyer, or infringements resulting from the modification, combination or use in a system of any Product sold hereunder. The foregoing provisions of this Section shall constitute Seller’s sole and exclusive liability and Buyer’s sole and exclusive remedy for infringement of Intellectual Property Rights.

19. Entire Agreement. This agreement contains the entire agreement between the Buyer and Seller and constitutes the final, complete and exclusive expression of the terms of sale. All prior or contemporaneous written or oral agreements or negotiations with respect to the subject matter are herein merged.

20. Compliance with Law, U. K. Bribery Act and U.S. Foreign Corrupt

Practices Act. Buyer agrees to comply with all applicable laws and regulations, including both those of the United Kingdom and the United

States of America, and of the country or countries of the Territory in which Buyer may operate, including without limitation the U. K. Bribery

Act, the U.S. Foreign Corrupt Practices Act (“FCPA”) and the U.S. Anti-

Kickback Act (the “Anti-Kickback Act”), and agrees to indemnify and hold harmless Seller from the consequences of any violation of such provisions by Buyer, its employees or agents. Buyer acknowledges that they are familiar with the provisions of the U. K. Bribery Act, the FCPA and the

Anti-Kickback Act, and certifies that Buyer will adhere to the requirements thereof. In particular, Buyer represents and agrees that Buyer shall not make any payment or give anything of value, directly or indirectly to any governmental official, any foreign political party or official thereof, any candidate for foreign political office, or any commercial entity or person, for the purpose of influencing such person to purchase products or otherwise benefit the business of Seller.

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

29

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Notes

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

30

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Notes

Parflange ECO 25

Hydraulic Flanging and Flaring Tool

31

Parker Hannifin Corporation

Tube Fittings Division

Columbus, Ohio http://www.parker.com/tfd

Parker Fluid Connectors Group

North American Divisions & Distribution Service Centers

Your complete source for quality tube fittings, hose

& hose fittings, brass & composite fittings, quickdisconnect couplings, valves and assembly tools, locally available from a worldwide network of authorized distributors.

Fittings:

Available in inch and metric sizes covering SAE, BSP,

DIN, GAZ, JIS and ISO thread configurations, manufactured from steel, stainless steel, brass, aluminum, nylon and thermoplastic.

Hose, Tubing and Bundles:

Available in a wide variety of sizes and materials including rubber, wire-reinforced, thermoplastic, hybrid and custom compounds.

Worldwide Availability:

Parker operates Fluid

Connectors manufacturing locations and sales offices throughout North America,

South America, Europe and

Asia-Pacific.

For information, call toll free...

1-800-C-PARKER

(1-800-272-7537)

North American Divisions

Energy Products Division

Stafford, TX phone 281 566 4500 fax 281 530 5353

Fluid System Connectors

Division

Otsego, MI phone 269 694 9411 fax 269 694 4614

Hose Products Division

Wickliffe, OH phone 440 943 5700 fax 440 943 3129

Industrial Hose Division

Strongsville, OH phone 440 268 2120 fax 440 268 2230

Parflex Division

Ravenna, OH phone 330 296 2871 fax 330 296 8433

Quick Coupling Division

Minneapolis, MN phone 763 544 7781 fax 763 544 3418

Tube Fittings Division

Columbus, OH phone 614 279 7070 fax 614 279 7685

Distribution Service Centers

Buena Park, CA

phone 714 522 8840 fax 714 994 1183

Conyers, GA

phone 770 929 0330 fax 770 929 0230

Lakeville, MN

phone 952 469 5000 fax 952 469 5729

Louisville, KY

phone 502 937 1322 fax 502 937 4180

Portland, OR

phone 503 283 1020 fax 503 283 2201

Toledo, OH

phone 419 878 7000 fax fax

419 878 7001

419 878 7420

(FCG Kit Operations)

Canada

Grimsby, ONT

phone 905 945 2274 fax 905 945 3945

(Contact Grimsby for other

Service Center locations.)

© 2013 Parker Hannifin Corporation Bulletin 4390-ECO25

Parflange is a registered trademark of Parker Hannifin Corporation.

Parker Hannifin Corporation

Tube Fittings Division

3885 Gateway Blvd.

Columbus, OH 43228 phone 614 279 7070 fax 614 279 7868 e-mail [email protected]

www.parker.com/tfd

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals