MP3743
MPPT Solar
Charge Controller
for Lithium or SLA Batteries
Instruction Manual
2
3
4
1
BOX CONTENTS:
1 x 12V/24V 30A MPPT Solar Charge Controller
1 x External Temperature Sensor
1 x User Guide
1 x App Guide
PRODUCT DIAGRAM:
5 6 7 8 9 10
1 LCD Screen
2 Green Indicator LED
3 Red indicator LED
4 External Temperature Probe
5 Solar Positive Input
6 Solar Negative Input
7 Battery Positive Input
8 Battery Negative Input
9 Load Positive Output
10 Load Negative Output
11 Up Button
12 Menu Button
13 Enter Button
14 USB Outputs
15 Down Button
16 Ethernet Socket
1
15
16
11
12
13
14
LCD SCREEN:
A B C D E F G
P
H I J K L M N O
A Solar Input Indicator
B Solar Current Indicator
C MPPT Charging Indicator
D WiFi Indicator
E Remote Control Indicator
F Setting Mode Indicator
G Load Switch Indicator
H Battery capacity indicator
I Load indicator
J Display indicator for current reading
K Battery type (12/24V)
L Protection Icon – See error codes
M Timing clock
N Timing clock
O Day/night indicator – set by PV input
P Reading display with unit type
2
BASIC FUNCTIONS:
Settings Menu
If the display is off, tap the Menu button to turn it on.
Press & hold the Menu button to enter the settings menu, and tap the Menu button again to cycle through each setting in the following order. Use the
Enter button to enter / save a setting.
# Menu Item
1 Battery Type
2 WiFi
3 Load Voltage Protection Cut Off
4 Load Under Voltage Recovery
5 24 Mode
6 Time
7 Load Timer
Options
Standard (STD) / Lithium (L) / AGM
(A)
On / Off
10 – 11.5V (12V) – Default 10V
20 – 23V (24V) – Default 20V
12 – 13V (12V) – Default 12.5V
24 – 26V (24V) – Default 25V
On / Off
Hours / Minutes
On / Off
When turned on, the next setting is used to set the Load on time
Factory Reset
With the unit turned off, press & hold the Menu button & power up the controller via the battery input. The screen will display FFFF to indicate all settings have been factory reset.
3
FAULT CODES:
E1 Battery has been installed with the polarity reversed.
E2 Battery is not currently connected, or is under the low voltage cut off.
E3 Battery over current protection enabled. If the issue persists, the controller may be faulty.
E4 Load over current / short circuit protection. Turn off the machine for 10 seconds to reset.
E5 Battery over voltage protection.
E6 Solar input over voltage protection.
E7 Over temperature protection. Charging will restart once the temperature is under 60’C.
E8 Solar input has been installed with the polarity reversed.
4
SPECIFICATIONS:
SOLAR
Maximum PV Open Circuit Voltage: 100V
MMPT Voltage:
Maximum PV Input Power:
Maximum MPPT Current:
16 – 80VDC
450W (12VDC) / 900W (24VDC)
30A
DC OUTPUT
Battery Voltage:
Output Current:
12/24VDC
30A
USB OUTPUT
Output Voltage
Number of USB Ports
Maximum Output Current:
STANDBY CURRENT
MPPT Charger Only:
MPPT Charger & WiFi:
PROTECTIVE FUNCTIONS
High / Low Voltage Protection:
Reverse Polarity Protection:
Temperature Cut Off:
5VDC
2
3.4A
60mA
160mA
High: 15V (12V) / 31V (24V)
Low: 8V (12VDC) / 18V (24VDC)
Yes
90°C
GENERAL
Dimensions:
Weight:
Operating Temperature:
Cooling method:
Insulation Class:
IP Rating
238 x 177 x 63mm
1.5kg
-10°C – 40°C
Heatsink
Class 1
IP30
5
NOTES:
6
Distributed by:
Electus Distribution Pty. Ltd.
320 Victoria Rd, Rydalmere
NSW 2116 Australia www.electusdistribution.com.au
Made in China