GA SERIES
HEAVY DUTY AIR CURTAIN
(3 Models with: 3, 4 and 5 Foot Coverage)
FOR COMMERCIAL AND INDUSTRIAL USE
(INDOOR USE ONLY)
Voltage: 110~120VAC, 60Hz
High Velocity Version:
Air Speed (At Nozzle: 2900 Ft/Min)
Installer: Please read this manual carefully and follow all instructions. Leave it with the owner after installation for future reference.
GA Series Commercial Air Curtain, User and Installation Manual
This air curtain was packed in the best possible way to avoid any shipping damages. Yet, although rare, some damages are unavoidable due to rough handling. Upon arrival, please inspect the air curtain carefully for any shipping damages. Please report any damages. Do not return to the shipper.
Replacements parts are available and will be provided free of charge by the shipper. All components can be easily replaced.
For service parts during and after the warranty period, please email [email protected]
with your model and serial number.
WIRING DIAGRAM: i n f r a r e d ray r e c e i v e r
cap aci to r
Magnetic Switch plug
bl ack wh it e gr een
earth
ora nge
blue w h i t e black red motor yellow/green earth
2
GA Series Commercial Air Curtain, User and Installation Manual
WORKING PRINCIPLE
Air curtains are designed to keep the air in the room separate from the outside air, thus preventing the heated or cooled indoor air from leaking outside and pests and obnoxious smells from entering inside. It creates an invisible air screen at the openings to the outside.
The unit should be installed above the opening to cover the entire width of an external door. Suggested height is between 8 to 10 feet from the floor level.
The air inside the room is sucked in by two centrifugal fans through the decorative front grilles and then directed through manually adjustable louvers downwards, all the way to the floor. Motor provides high and low speed settings which can be selected by the user.
3
GA Series Commercial Air Curtain, User and Installation Manual
CHOICE OF MODEL
The air curtain should have the same length as the width of the door, over which it will be installed. If necessary, two or more curtains can be installed side by side, to attain uniform coverage across the entire opening.
To obtain maximum performance, the air outlet should be positioned in immediate correspondence with the top edge of the door and the air flow speed at ground level must be between 300 and 500 foot/min.
GA series air curtains are equipped with 6 inch diameter centrifugal blowers and provide excellent coverage when installed at heights up to 12 feet max.
(preferably between 8 and 10 feet) from the floor.
INSTALLATION
Installation location
The installation location of the air curtain must be indoors only, on a solid and vibration free wall. Do not install the appliance in an excessively humid location or in a place where it can be easily sprayed with water. If possible avoid installing the unit where there is direct sunlight.
If the door is wider than the air curtain, two or more units can be installed side by side.
Installation of the Mounting Frame:
1) After removing the appliance from the packing, separate the mounting frame from the air curtain (attached to the back of the unit at the factory as packed);
2) If included, remove the styrene protective inserts, placed inside the unit to prevent the blower wheels from damage during the shipment (see separate instructions).
3) Position the mounting frame so it is perfectly level and mark the fastening holes (see the drawings provided for details);
4) Fasten the mounting frame to the wall using screw anchors which are suitable for the type of wall;
5) Hook the air curtain on to the mounting frame and fix it using the provided screws at the bottom part.
There should be no space left between the curtain and the wall once installation is complete.
4
GA Series Commercial Air Curtain, User and Installation Manual
Installing on a concrete wall:
1) Drill holes with a diameter of ½ Inch and 3 Inches depth.
2) Insert expansion bolts (1/2 x 3) into the holes and mount the mounting frame with the rectangular holes.
Hang the unit body on and tighten the fixing screws at the bottom.
Installing on the wooden wall:
Fix the mounting frame with the proper wood screws on the chosen position.
Hang the unit body on and tighten the fixing screws at the bottom.
Start up
Once installation is complete, connect the power supply cable to the 110~120V receptacle. This air curtain is equipped with a three-lead electric cable (line, neutral, Ground), which should be connected to properly grounded and receptacle with proper protection.
LOUVER ADJUSTMENT
The adjustable louvers allow the air flow to be directed as required.
Usually the louvers are to be pointed vertically, to direct the air flow vertically towards the floor.
If the air curtain is installed in a windy area the louver can be pointed slightly towards the outside, in order to balance the wind force.
5
GA Series Commercial Air Curtain, User and Installation Manual
WARNINGS: i. Connect the unit to a power socket protected by a thermal-magnetic safety switch suited to the electrical input of the appliance. ii. Use the push button switches to start, stop, or change the speed of the unit. Or use the Remote Controller. iii. When the air curtain is working or not, never insert fingers or any other things into inlet grill or outlet grills, to prevent serious injury and damage to the unit or other property.
DOOR SWITCH OPTION (Optional):
When equipped the magnetic door switch controls the air curtain based on the opening and closing of a door below. If the entry point where the air curtain is equipped with a door and user desires to run the air curtain automatically, only when the door is opened, than install the door switch to the door. When the 2 pieces of the door switch and aligned against each other closely, the air curtain will stop.
If the door switch is not installed to the unit, it will run all the time when turned on by the controller, until it is turned off again. This is recommended for the areas without a door installed.
MAINTENANCE
Unit cleaning and maintenance:
Remove the plug or turn off the automatic circuit-breaker before carrying out any cleaning operations.
Clean the air intake and outlet grilles with a soft cloth, warm water (maximum 100 F) and mild detergent.
Do not use solvents or harsh detergents.
If the inside of the air curtain needs to be cleaned , remove the grilles and use a jet of air or a vacuum cleaner to get rid of the dust .
Lubricate the bearings of the electric motor and the fan at least once a year.
IF THE AIR CURTAIN DOES NOT WORK
If the unit gives no signs of life, make sure that the power is reaching to the unit:
– is the plug inserted properly
?
– has the automatic circuit-breaker tripped
?
– has there been a power failure
?
6
GA Series Commercial Air Curtain, User and Installation Manual
0 1
Parts Diagram:
M 4
02
0 3
04
0 5
M4
06
07
08
M6
M4
09
M6
M4
10
M4
M4
1 1
12 13
M8
NO.
Model
Description
01 Air inlet grill
02 Case body
03 Air outlet grill
04 Cross fan wheel
05 Bearing support
06 Under pan
07 Motor
08 Power wire
09 Infrared ray receiver
10 Capacitor
11 Soleplate
12 Scale board
13 Pin
3 Foot
Part code
1250901
1250902
1250903
1250904
1250905
1250906
1250907
1250908
1250909
1250910
1250911
1250912
1250913
4 Foot
Part code
1251201
1251202
1251203
1251204
1251205
1251206
1251207
1251208
1251209
1251210
1251211
1251212
1251213
5 Foot
Part code
1251501
1251502
1251503
1251504
1251505
1251506
1251507
1251508
1251509
1251510
1251511
1251512
1251513
7
GA Series Commercial Air Curtain, User and Installation Manual
A Quality Product of
Parker Davis HVAC International, Inc.
2260 NW 102 Place
Doral, FL 33172
Tel : (305) 513-4488
Fax : (305) 513-4499
Corporate Site : www.pd-hvac.com
Online Sales : www.highseer.com
Designed in U.S.A., Manufactured in China under strict quality control standards.