MITSUBISHI AL-232CAB INTERFACE CABLE Operating instructions


Add to my manuals
90 Pages

advertisement

MITSUBISHI AL-232CAB INTERFACE CABLE Operating instructions | Manualzz

FX-Family

MELSEC PLC

The world’s favorite micro PLCs

10 Million FX PLCs Worldwide ///

Over

30 Years Experience ///

Expanded Micro PLC Control /// Networking Solutions ///

Analog Solutions /// Positioning Solutions ///

Global leader /// Global leader /// Global leader /// Global leader /// Global

Global Leader

The MELSEC FX3U/FX3UC series are the third generation on programmable controllers of the Mitsubushi Electric FX family.

They offer improved network capability and solutions for positioning tasks.

10 Million FX

The FX Family of PLCs is the PLC of choice across the world, industries and applications.

Mitsubishi Electric has always worked closely with its customers to design the

PLC that they want for their applications.

The manufacturing and use of 10 million

FX CPUs is a demonstration that this close working relationship has delivered quality, reliability and the product that customers want.

Over 30 Years

The FX Family of PLCs has been an important part of control engineering for over

30 years. Throughout its history, the product has evolved from the original F Series into today's current FX3G series.

The FX Family has proven to be highly reliable and it consistently improves its compatibility with previous PLC generations.

Number 1 in the world

Mitsubishi Electric was shown to be the largest volume producer of PLCs in the world following the 2004 Worldwide

PLC survey by the respected American automation research company ARC.

2 ARC is protected by ARC Advisory Group copyright 2004

/// Contents /// Contents /// Contents /// Contents /// Contents /// Contents

Contents

What makes a world leading PLC?

Range overview

FX3U/FX3UC, a new concept in PLCs

FX3G, an automation standard

FX1N, the modular micro

FX1S, micro control

Programming and software

Networking

Analog solutions

Positioning solutions

Displays solutions

Applications

Section 2: Technical Informations

13

14

11

12

7-9

10

4-5

6

17

18

15

16

3

World leading PLCs /// World leading PLCs /// World leading PLCs /// World l

What makes a world leading PLC range?

Adapter or "ADP" units are used on the left hand side of the main PLC unit.

Memory cassette port is located under the removable front cover.

Global use

Wide range power supply means your

FX solution will work all over the world.

International acceptance

Shipping approvals such as Lloyds, German

Lloyds, ABS, RINA, Det Norse Vetaritas, for example plus CE and E1 compliance for

Low Voltage and EMC directives as well as manufacturing to Automotive industry quality levels, make the FX Family PLCs products to trust.

The standard RS422 Mini-DIN programming port can also be used for HMI connection.

Optional communication boards are available in USB, RS232C,

RS422 and RS485 formats.

The RUN/STOP switch has become a familiar feature with all FX Family PLCs.

Flexible design

The FX Family is designed so that the main

PLC CPU acts as a platform to which you can add and customize the special functions you need – making every FX your personal PLC.

4

eading PLCs /// World leading PLCs /// World leading PLCs /// World leading

Main base unit where CPU,

I/O and power supply are contained in a single unit.

All FX PLC units can be mounted on a DIN rail or directly mounted with screw fixings.

Easy

Programming

The FX Family incorporates an easy programming concept where several complex tasks can be reduced to a single instruction.

Fast and reliable

FX PLCs continually push the limits of high speed operation to process your applications more effectively and accurately.

Simple ribbon connection links each unit together.

Bright LED lamps indicate I/O and power status.

Special function blocks can be added to the right hand communications bus of the PLC.

Compatibility

The FX Family of PLCs continues to raise the level of backward compatibility with many existing FX PLC programs being transferable. And in later models, sharing common peripherals and special function blocks means even greater protection for your investment in both FX and the machine or process being controlled.

5

The power to perform /// The power to perform /// The power to perform /

The power to perform

/ FX3UC

Ultra high speed, maximum performance and a simplified design concept make this the ultimate micro PLC.

FX3G

Advanced control, multiple communication possibilities and a wide range of options make this PLC an industry leader.

FX1N

This powerful micro brings the flexibility of the modular

PLC design concept but, with the ease of use typical of

FX Family PLCs.

FX1S

A compact micro controller for simple applications, supported by a strong communications capability.

I/O

The FX Family of PLCs builds on previous performance and capability, ensuring you have a comprehensive range of control and automation options to choose from.

Model

Power supply

Maximum I/O

Digital I/O

Cycle period/ logical instruction

PLC program memory

FX1S

100–240 V AC,

24 V DC

30

(34 optional)

Relay/

Transistor

0.55 µs

2 k steps

FX1N

100–240 V AC,

12-24 V DC

128

(132 optional)

Relay /

Transistor

0.55 µs

8 k steps

FX3G

100–240 V AC

256**

Relay /

Transistor

0.21 µs or 0.42 µs

32 k steps

FX3U

100–240 V AC,

24 V DC

384*

Relay /

Transistor

0.065 µs

64 k steps

FX3UC

24 V DC

384*

Transistor

0.065 µs

64 k steps

Summary table of FX PLCs

Note * : When networked with CC-Link or AS-Interface (Discrete I/O, maximum 256)

Note ** : When networked with CC-Link or AS-Interface (Discrete I/O, maximum 128)

A solution for every application

Micro PLCs have opened up a world of opportunities in Industrial Automation due to their small size and low cost. Now many applications benefit from enhanced performance, easier manufacturing, maintenance and greater reliability.

The FX Family has been a part of this revolution for over 30 years and has developed and redeveloped a range of products to suit most applications. The FX Family consists of four main ranges which are distinct and independent but compatible.

Depending on your application and control needs, you can choose from; the simple

FX1S CPU, the modular FX1N range, the powerful FX3U and now the current and dynamic FX3G.

With the FX Family there really is a solution to most applications.

6

/// FX3U a perfect PLC concept /// FX3U a perfect PLC concept /// FX3U

The FX3U has an enhanced communications bus that automatically switches into high speed mode for communication with new FX3U expansion modules.

Full compatibility is still available with

FX2N and FX0N expansion blocks, and when these are configured the FX3U automatically reduces the bus speed to suit.

This means greater support for existing installed systems as well as delivering high performance and greater response with new installations.

Adapters add flexibility

A major design enhancement of FX3U is the new adapter expansion bus on the left hand side of the FX3U CPU. Through this bus users can add additional analog and temperature units as well as multiple communications and positioning blocks.

FX3U a perfect

PLC concept

The FX3U CPU brings a combination of greater flexibility and increased performance to the FX Family.

New high speed bus

The FX3U design has increased the opportunity to configure the PLC directly for your needs.

Following the standard FX Family configuration, the FX3U CPU can be expanded to the right hand side using a wide range of options. These include input and output blocks as well as special function blocks such as analog, pulse train and network communication units.

FX3U has a unique new system of directly programmable adapters.

However, the major benefit for the user is that the analog and positioning adapter units no longer require the use of the traditional To/From instruction to configure and operate.

All control is through direct access data registers and setting bits. This means quicker set-up, easier use, and above all much higher processing speeds.

The FX3U can use new FX3U blocks as well as standard FX2N and FX0N expansion blocks..

7

FX3U/FX3UC a perfect PLC concept /// FX3U/FX3UC a perfect PLC concept /// F

FX3U/FX3UC. More power.

More performance.

FX3U/FX3UC Base Unit Expansion I/O

Network master

Maximum

256 I/O

Remote I/O Remote I/O Remote I/O

Remote network stations

FX3U/FX3UC provides additional I/O and networking capacity.

Maximum

256 I/O

System Maximum

384 I/O

Increased I/O capacity

With enhanced networking functions, the

FX3U/FX3UC requires an increased input/ output (I/O) range. FX3U/FX3UC can support systems with combined local I/O and networked I/O up to a total of 384 I/O points. For users, this means increased system control and added possibilities for advanced networks.

In addition FX3U/FX3UC also fully supports Profibus/DP as well as Ethernet using

TCP and UDP protocols.

Basic instruction

Applied instruction (MOV)

FAST

FAST

FX3U/FX3UC provides increased performance in all areas.

Note: 4.5 times increase in speed is measured under the following conditions: program capacity=16 k step, with an I/O usage of 144 points. Program scan time is then; FX3U/FX3UC:

4.6 ms and FX2N: 21.0 ms, an increase in processing speed of

4.56 times.

Up to 4.5

times faster

This means the PC MIX value has been greatly improved with basic instructions now being processed in 0.065 µsec.

For users this means quicker program response and more accurate process performance as inputs, outputs and actions are processed and monitored more times per second.

Auxilliary Relay (M)

State Flags (S)

Timers (T)

Data Registers (D)

7680 points

3072 points

4096 points

1000 points

512 points

256 points

40768* points

8000 points

*Includes R Registers

FX3U/FX3UC offers increased resources as well as increased performance.

8 times more memory

FX3U/FX3UC comes with a standard internal memory of 64 k steps, which is 8 times more memory than FX2N.

More memory means users can write larger and more complex programs, store more data in file registers, or take greater advantage of using IEC 61131-3 style programming tools.

8

5 times more data storage

With a larger program memory comes the need for more operational devices such as timers, state flags, auxiliary relays and data registers. The FX3U/FX3UC has increased capacity in all of these major areas making program construction easier. Data register capacity has increased by a factor of

5 reflecting the needs of users who have an increased requirement to log operation information against products or batches of products being manufactured.

A typical example of this can be found in the Food and Pharmaceutical industries.

Here exact process data such as oven temperatures and cooking times or quantities of ingredients mixed need to be stored against production batches – all this requires increased data handling and data capacity within the PLC.

75 new instructions

The FX3U/FX3UC has 75 new instructions in comparison with FX2N. This now makes available 249 instructions for program creation. All of the instructions follow the traditional FX Applied instruction concept designed to make the task of application building and program writing easier and quicker, with less chance for errors.

FX3U/FX3UC a perfect PLC concept /// FX3U/FX3UC a perfect PLC concept ///

New instructions include greater control over data processing with a range of new comparison and string manipulation commands.

LOGE (Nr. 125)

Calculates the natural logarithm in floating point

SORT2 (Nr.149)

Sort tabulated data

TBL (Nr. 152)

Batch data positioning mode

BAND (Nr.257)

Defines a band or range of valid numbers

IVWR (Nr.273)

Write parameter to inverter

RS 485

RS 232

GOT1000

Inverter multidrop

Some examples of new instructions from the FX3U/FX3UC.

Inverter 1

FX3U/FX3UC has a range of flexible communication options.

RS 422

Inverter 8

USB

Simple high speed positioning

The FX3U/FX3UC has been designed with six high speed counters that can each count up to 100 kHz simultaneously per channel.

This, combined with three 100 kHz pulse train outputs, means users can directly configure simple 3-axis positioning systems without the use of additional modules.

A great communicator

FX3U/FX3UC has strengthened the communications capability of the FX Family even further.

The new adapters allow up to three RS communication channels to be operated simultaneously allowing multiple HMIs to be connected to a single FX3U/FX3UC CPU or combinations of HMIs, third party devices and programming tools – the choice is yours.

The FX3U/FX3UC also supports a wide range of network options including

AS-interface, Profibus-DP, CC-Link,

DeviceNet, CANopen as well as Ethernet.

Adapter modules increase positioning performance.

The FX3UC is the ideal choice for applications where there is not much space for the controller hardware. The smallest base unit with 8 digital inputs and 8 transistor outputs takes up just 27 % of the space required for a comparable FX3U unit – and yet the FX3UC incorporates all the features of the FX3U.

However, the new high speed counter ADP and pulse train ADPs can provide the

FX3U/FX3UC with maximum positioning performance. Each unit can process signal speeds of up to 200 kHz.

The connections for the FX3UC inputs and outputs on the front side can be wired with ribbon cable connectors. For this purpose system cabling sets and remote I/O terminal blocks for easy and fast connections are available.

FX3U/FX3UC at a glance

I/O range

16–384 (Discrete I/O, maximum 256)

Program memory

64 k steps (standard)

Basic instruction processing

0.065 µsec/logical instruction

Analog signal processing

Up to 80 analog inputs,

Up to 48 analog outputs

Analog resolution

8, 12 and 16 bits

Analog options

19 analog input, output and temperature blocks available for selection

Positioning

Internal:

6 high speed counters (100 kHz)

2 high speed counters (10 kHz)

3 pulse train outputs (100 kHz), transistor unit only

External (FX3U only):

High speed counter block (50 kHz)

High speed counter ADP module

(200 kHz)

Pulse train ADP (200 kHz)

Pulse train output block (1 MHz)

9

FX3G powerful micro control /// FX3G powerful micro control /// FX3G ///

FX3G an industry standard

FX3G PLCs are used in many applications for processing and packaging as well chilled storage and transportion of food items.

Since its launch, the FX3G has been a standard of micro PLC control.

Customized control

The FX3G is an introductory compact PLC and is the newest addition to the FX3 series, designed for simple yet performance-critical applications that require discrete control of up to 128 local I/O or up to

256 I/O with CC-Link remote I/Os.

Incorporating innovative FX3 series technology the customer is presented with a suite of benefits. These include a large program memory to implement sophisticated algorithms plus high speed execution to enhance system productivity.

Highly flexible

A dual bus architecture provides flexible expansion possibilities and with the ability to handle analog, high speed, positioning, and inverter control, the FX3G is able to successfully adapt to a range of applications in industry areas such agriculture, water processing, material handling, food processing and more.

The great communicator

With a wide range of network and serial protocols available, such as Ethernet,

CC-Link and Modbus, the FX3G enables seamless integration and data communications between both Mitsubishi Electric and third-party devices. Furthermore, a built-in

USB port permits convenient connection to any PC or laptop.

FX3G at a glance

I/O range

14–256 (Discrete I/O, maximum 128)

Program memory

32 k steps (internal)

Basic instruction processing

0.21 µs or 0.42 µs/logical instruction

Analog signal processing

Up to 74 analog inputs

Up to 41 analog outputs

Analog resolution

8, 12 and 16 bit

Analog options

19 analog input, output and temperature blocks available for selection

Positioning

Internal:

Up to 4 high speed counters (max. 10 kHz) up to 2 high speed counters (max. 60 kHz) up to 3 (2) pulse train outputs (100 kHz)

FX3G has the versatility to handle applications from a wide range of industries.

10

/ FX1N modular micro /// FX1N modular micro /// FX1N modular micro ///

FX1N the modular micro

Powerful performance

The FX1N saves space, cost and engineering time with the use of powerful, built in, positioning tools such two 100 kHz pulse train outputs and up to two 60 kHz high speed counters. These can be used to create simple 2-axis positioning systems, linked to servo amplifiers or stepper motor drivers without the need for additional PLC hardware saving space, cost and engineering time.

FX1N has six shipping approvals. It has been used in applications from controlling temperature in containers to managing diesel engines.

The FX1N offers comprehensive expansion options.

The FX1N provides a simple introduction to modular micro control offering comprehensive functionality and expansion options.

Compatibility cuts costs

The FX1N provides many user benefits including excellent compatibility with other FX Family PLCs. The FX1N is upwardly compatible to the FX2N/FX3G using many of the FX2Ns I/O and special function blocks. It also shares the same programming structure as the FX1S. This means that users benefit from learning and using one PLC programming syntax; resulting in faster program development and reduced programming errors.

In addition, users benefit from a reduced stock and spare parts requirement as the

FX1N uses the same expansion boards as the FX1S and the same special function and expansion I/O blocks as the FX2N.

FX1N at a glance

I/O range

14–132

Program memory

8 k steps (standard)

Basic instruction processing

0.55 µsec/logical instruction

Analog signal processing

66 analog inputs

33 analog outputs

Analog resolution

8, 12 and 16 bits

Analog options

12 analog input, output and temperature blocks available for selection

Positioning

Internal:

2 high speed counters 60 kHz,

4 high speed counters 10 kHz

2 pulse train outputs (100 kHz), transistor unit only

11

FX1S micro control /// FX1S micro control /// FX1S micro control /// FX1S //

FX1S micro control

Remote control

The FX1S has an additional range of BD expansion boards providing RS232,

RS485 and RS422 communications options. These can be used to connect and control various third party products such as bar code readers or panel printers.

Simple programming

The FX Family has a simple programming structure combining Basic and Applied instructions. The Basic instructions are common to all FX Family PLCs. Applied instructions provide the specialist control options such as data comparisons, PID and communications control, all of which are available on FX1S. As each FX PLC range increases in capability (FX1S, FX1N, FX3G,

FX3U/FX3UC) so do the number of available Applied instructions.

FX1S has been used in a wide range of embedded control applications.

FX1S offers communication and real time control from a single unit.

Fit and forget

Typically FX1S applications are small, embedded control functions that are hidden away or unaccessible under normal maintenance activities. This is why the FX1S has been designed to be a robust low maintenance PLC. Features such as the maintenance free, 2000 step EEPROM memory and real time clock management all help to make the FX1S a self managing system, reducing the impact on the maintenance engineer.

FX1S at a glance

I/O range

10–34

Program memory

2 k steps (standard)

Basic instruction processing

0.55 µsec/logical instruction

Analog signal processing

Up to 2 points

Analog resolution

12 bits

Analog options

2 analog input BD board

1 analog output BD board

Positioning

Internal:

2 high speed counters 60 kHz,

4 high speed counters 10 kHz

2 pulse train outputs (100 kHz), transistor unit only

Example of connectivity to 3rd party products

12

/// Programming /// Programming /// Programming /// Programming ///

Progressive software concepts

The Mitsubishi FX PLC Family has a worldwide reputation for reliability, performance and ease of use. These key values have also been used to form

Mitsubishi’s integrated software concept, MELSOFT.

Simple and intuitive

Productivity tools

Programming software for PLCs is constantly evolving. Users are placing more focus on reusable program code and function block concepts. This helps to reduce errors, reduce programming time and to help manage the whole programming process – increasing overall productivity.

GX Developer offers ease of use for programmers of all skill levels.

The key to any good software is that it is simple to use. Mitsubishi’s GX Developer

PLC programming packages have achieved this by using intuitive design.

One step further with iQ Works

Mitsubishi Electric's iQ Works software is a suite of four MELSOFT software packages that enable intuitive programming and setup of an iQ Platform system, including system/network configuration, Q and FX

Series programming, Q Motion Controller and Servo setup, GOT1000 HMI screen design. This next generation software provides a fully customizable user friendly environment with the developers in mind.

First time user?

For users who do not have the time to take local training, there is the option of using Mitsubishi’s home study software,

FX-TRN-BEG, where PLC programs can be created, simulated and debugged in the safety of a PC simulation.

They also have comprehensive help functions and an advanced communications layer, ensuring safe reliable communication to the target PLC.

Often the biggest cost on a project is engineering time.

Choose what you need

GX Developer offers users the chance to program all Mitsubishi MELSEC PLCs from a single package. However, for users who only need support for FX based systems there is GX Developer FX.

Mitsubishi also provide GX IEC Developer packages, providing IEC61131-3 compliant programming in; Instruction List,

Ladder, Function Block, Structured Text and SFC formats. Using standard programming languages, like IEC61131-3, on large programming projects can help users save costs by creating reusable PLC code and Function Blocks.

Learning to program can be achieved quickly using interactive software.

MELSOFT is a wide range of software solutions designed to optimize your plant productivity.

13

Networking solutions /// Networking solutions /// Networking solutions /

Networking and communication solutions

Remote maintenance

With communications technology it is now possible to put PLC control in the most remote locations. Using a PLC with a RS232 interface to a telemetry solution, such as a

GSM modem, allows the user the ability to remotely monitor and maintain the system. It can also allow the remote system to send alarm messages, warnings or general status information back to the user’s central data processing centre.

FX Family PLCs have a wide range of communications options.

Applications are often required to integrate between each other across a factory, to report production or tracking data back for office based processing and in some cases be remotely monitored and maintained when the application is in an inaccessible location. The FX Family of PLCs has evolved to match this demand at all levels.

Networks make sense

Networked solutions to complex applications often make the overall solution easier to achieve and more cost effective. For example a conveyor system integrated with a warehouse pick and place system may extend over many hundreds of meters, and by using a fieldbus, such as CC-

Link, wiring, troubleshooting and maintenance can be dramatically reduced.

Example of remote pumping station.

Easy communications

Today’s FX Family of PLCs share a basic communication concept where additional

RS232, RS422 or RS485 communications boards can be added to the main base unit without increasing the required cabinet space. These can then be used for communication to various third party devices like bar code readers, printers and modems.

FX Family PLCs, such as FX1N, FX3G, FX3U and FX3UC, have a wider range of communications modules. These include options for connection to open and bespoke networks such as Ethernet, Profibus-DP,

CC-Link, DeviceNet, CANopen, AS-interface or Modbus for example.

14

Networking solutions /// Networking solutions /// Networking solutions /// Analog solutions /// Analog solutions /// Analog solutions /// Analog

Analog solutions

Analog control is one of the most important areas for any automation system.

Critically for users the concern is to match the performance demanded by the application to the available solutions in a cost effective way.

Where is analog used?

Analog control is widely used. In simple terms it allows a variable signal to be used to control items such as a motor’s speed or to sense inputs such as fluid levels.

Digital to analog (D-A) control

Here a digital PLC value is output as an analog signal. It can be used, for example, to send a speed command to an inverter which in turn causes the motor to increase or decrease speed.

Analog to digital (A-D) control

In this type of control a variable signal is sent to a PLC where it is converted in to a direct digital value. An example of this could be the measurement of the level of a liquid in a storage tank so that the exact amount of stored liquid can be controlled by the PLC.

Temperature control

Temperature control is the third type of analog control. An example of use could be where the temperature of a furnace is measured and compared by the PLC against a set range. Additional heating or cooling can then be applied to maintain a constant temperature.

Inverter

Example: D-A control can be used to set the speed of an inverter driving a motor.

Example:

Temperature control keeps the liquid at the correct viscosity.

Example:

A-D control can be used to control the filling speed of the container.

Analog solutions are an important part of control engineering and can be used to simplify and accurately control actions happening in the production environment.

22 solutions to choose from

The FX Family offers a wide range of analog solutions from 1 and 2 channel BD boards for FX1S up to 8 channel input blocks like the FX2N-8AD where temperature, voltage and current input can be mixed on the same block. FX analog blocks also come in a range of resolutions from 8 bit up to

16 bit signal processing. Overall there are

22 different analog options available to users of the FX PLC Family.

With this range of choice and flexibility it is sure that there will be a solution here for most applications.

Example of temperature control.

15

Positioning solutions /// Positioning solutions /// Positioning solutions /// Displays /// GOTs /// Displays /// GOTs /// Displays /// GOTs /// Displays ///

Positioning solutions

X-Y table for simple shaping

The larger the range of output pulse frequencies available means greater speed and/or accuracy is achievable. For example, if a stepper motor with a larger number of steps is used, the travel distance per step can be reduced, resulting in an increased system accuracy.

High speed counter input

When a motor is being driven, its relative position can be controlled by counting the number of output pulses.

However, for a more accurate process,

reading the actual position from an encoder feedback directly into a high speed counter is preferred. This helps to overcome issues of backlash and slippage as the actual position is measured and not assumed.

Horizontal drill station

Vertical drill station

Positioning built in as standard

Simple positioning solutions can be effectively managed within a standard FX PLC.

Using simple positioning solutions can help increase the accuracy of the work process, reduce waste and rework as well as provide a higher quality of production.

FX PLCs come with high speed counters

(in some cases up to 100 kHz) and pulse train outputs (also in some cases up to

100 kHz) as standard. The high speed counters can be configured in single pulse train inputs, The high speed counters can be configured in a single or two phase input.

Pulse train outputs can be configured to provide continuous pulse streams at different frequencies or a set quantity of pulses at a single frequency.

Typical applications

Simple positioning applications typically involve independently controlled operational axis and can sometimes have many requirements. In the example of an X-Y table, a relative position is achieved by driving each axis until its target position is achieved, regardless of what happens with the other axis. There are two main elements to achieve this type of positioning control.

Pulse train outputs

A stream of output pulses can be used as a drive signal to a line driver, stepper motor or servo amplifier, which then causes the connected motor to perform the positioning activity.

There are also optional modules and adapters that can provide additional high speed counters with performance up to

200 kHz. The same is true for pulse train outputs with 200 kHz and 1 Mpps (1 MHz) output options available.

Example of conveyor belt control.

16

Positioning solutions /// Positioning solutions /// Positioning solutions /// Displays /// GOTs /// Displays /// GOTs /// Displays /// GOTs /// Displays ///

Display solutions

An increasingly important area of any automation solution is the reporting and display of operational information. This data enables operators, maintenance teams and business managers to make informed decisions in the best interests of the business.

The right tool for the right job

For maximum efficiency, each user requires access to information at their work place in a form that highlights the important data for them first. This means a range of different tools are required. As an example, here are three possible scenarios.

The machine operator

Machines often have a lot of manufacturing debris around or are subject to hygienic cleaning as in the food industry. Any display located in this environment would need to have a high Ingress Protection (IP) rating, indicating a high degree of waterproofness.

In the food industry hygiene is very important.

The maintenance team

The critical information for a maintenance engineer is the error and diagnostic data within the PLC as this is used to diagnose any process problems. However, additional

The FX3U-7DM can be directly mounted within the PLC (FX3U) or mounted on the front cabinet.

information regarding the operational

"hours run" or cycles processed, which could be called soft information as it is calculated on operational parameters, could allow the maintenance engineer to predict possible failure and arrange preventative maintenance.

Access to this data could be through the machine operator's terminal, across a network or through a dedicated display mounted inside or on the control cabinet itself.

The business manager

In a production controllers office it would be better to display information through a network to their existing desktop PC. In this application a piece of software such as an OPC server/client, a Java applet, an

Active X control or a SCADA system would allow lots of data from lots of sources to be displayed in a clear and concise way giving the production controller the overview of the business operation that they need.

The GOT1000 is a typical HMI.

It may also be a benefit to the operator to have a large and clear display to reduce the chances for error from misreading, due to poor light or small fonts being used. It is also recognized that the use of graphics also reduces the chances for reading errors with complex data.

Data the way you want it

Mitsubishi offers a wide range of visualization solutions from simple data displays such as the FX3U-7DM, advanced Graphic Operator

Terminals like the GOT1000 Series and E1000

Series, and a wide choice of software solutions from the MELSOFT software suite.

This powerful combination of hardware and software means there is a cost effective solution for most applications.

17

Application solutions /// Application solutions /// Application solutions /// Automation solutions /// Automation solutions /// Automation solutions

Where have FX PLCs been used?

Sanitation management on Eurostar rollingstock.

18

Customer applications with FX PLCs have been wide spread from critical applications in pharmaceutical industries to sublime applications in the leisure industry.

However, the FX PLC Family still remains the PLC of choice for many machine builders as it is flexible, compact and easy to use, which is why it is so often used.

Here are just a few examples of applications that customers have completed in the past

Agriculture

– Plant watering systems

– Plant handling systems

– Saw mill (wood)

Building management

– Smoke detection monitoring

– Ventilation and temperature control

– Lift (elevator) control

– Automated revolving doors

– Telephone management

– Energy management

– Swimming pool management

Construction

– Steel bridge manufacturing

– Tunnel boring systems

Food and drink

– Bread manufacture (mixing/baking)

– Food processing (washing/sorting/ slicing/packaging)

Leisure

– Multiplex cinema projection

– Animated mechatronics

(museums/theme parks)

Medical

– Respiration machine testing

– Sterilization

Pharmaceutical/chemical

– Dosing control

– Polution measurement systems

– Cryogenic freezing

– Gas chromotography

– Packaging

Plastics

– Plastic welding systems

– Energy management systems for injection molding machines

– Loading/unloading machines

– Blow molding test machines

– Injection molding machines

Printing

Textiles

Transportation

– Sanitation on passenger ships

– Sanitation on rail rolling stock

– Fire tender, pump management

– Waste disposal truck management

Utilities

– Waste water treatment

– Fresh water pumping

Swimming pools are managed using FX PLCs.

ALPHA

///

FX1S

///

FX1N

///

FX3G

///

FX3U

///

FX3UC

///

Technical Information Section

Further Publications within the PLC Range

Brochures

System Q Family

Product catalogues for programmable logic controllers and accessories for the further MELSEC PLC series

HMI Family

Product catalogue for operator terminals, supervision software and accessories

Inverter Family

Product catalogue for frequency inverters and accessories

Servo and Motion Systems

Product catalogue for servo amplifiers and servo motors as well as motion controller and accessories

Robots Family

Product catalogue for industrial robots and accessories

Low Voltage Switchgears

Product catalogue for low voltage switchgears, magnetic contactors and circuit breakers

Automation Book

Overview on all Mitsubishi automation products, like frequency inverters, servo/motion, robots etc.

More information?

This product catalogue is designed to give an overview of the extensive range of FX Family of MELSEC PLCs. If you cannot find the information you require in this catalogue, there are a number of ways you can get further details on configuration and technical issues, pricing and availability.

For technical issues visit the www.mitsubishi-automation.com website.

Our website provides a simple and fast way of accessing further technical data and up to the minute details on our products and services. Manuals and catalogues are available in several different languages and can be downloaded for free.

For technical, configuration, pricing and availability issues contact our distributors and partners.

Mitsubishi partners and distributors are only too happy to help answer your technical questions or help with configuration building.

For a list of Mitsubishi partners please see the back of this catalogue or alternatively take a look at the "contact us" section of our website.

About this product catalogue

This catalogue is a guide to the range of products available. For detailed configuration rules, system building, installation and configuration the associated product manuals must be read. You must satisfy yourself that any system you design with the products in this catalogue is fit for purpose, meets your requires and conforms to the product configuration rules as defined in the product manuals.

Specifications are subject to change without notice. All trademarks acknowledged.

© Mitsubishi Electric Europe B.V., Factory Automation - European Business Group

2 MITSUBISHI ELECTRIC

System Description

ALPHA and MELSEC PLC system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Extension modules and special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

1

ALPHA Controllers

Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Extension units and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2

MELSEC FX Base Units

FX1S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

FX1N series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

FX3G series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

FX3U series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

FX3UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

3

MELSEC FX Extension Units

Powered compact extension units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Unpowered modular extension blocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

4

MELSEC FX Special Function Modules

Analog modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Temperature control modules/Data logger modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

High-speed counter modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Positioning modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Network modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Communications modules, Interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Adapter boards and communications adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

5

Accessories

Expansion Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Memory media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

External Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Power supply units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Backup batteries, Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Display modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

6

Dimensions

Base and extension units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

7

Software & Programming

Trainings and programming software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Programming unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Others

Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

CONTENTS

///

5

6

7

3

4

1

2

MITSUBISHI ELECTRIC 3

///

SYSTEM

DESCRIPTION

ALPHA and MELSEC PLC Systems

The ALPHA Series

The ALPHA closes the gap between single components and a PLC system. It combines all advantages of a PLC system in a very compact housing and therefore provides a space and cost saving alternative to relays and contactors.

The ALPHA series is suited to applications in industrial machines and in automated building services.

Key enhancements in the ALPHA2 include a program capacity of 200 function blocks, an extra-large display, expansion options and a second communications port. The instruction set, includes math operations,

PWM and SMS text messaging functions.

All this opens up possibilities for analog and temperature control as well as remote operation.

The MELSEC FX Family

The MELSEC FX family includes a very comprehensive range of base and expansion modules, enabling you to configure a customised system tailored to your precise requirements.

Depending on your application and control needs you can choose from the small, attractively-priced, "stand-alone" FX 1S series, the expandable FX 1N series or the more powerful FX 3G and FX 3U series.

With the exception of the FX 1S all FX series can be expanded to adapt them to the changing needs of your installations and applications.

Network integration is also supported, making it possible for your FX controllers to communicate with other PLCs, controllers and HMIs. The PLC systems can be configured as local stations in MITSUBISHI networks. In addition these flexible units can also be used as master or slave units on fieldbus’s like Profibus/DP and CC-Link.

The MELSEC FX Family controllers also support CANopen, DeviceNet,

AS-Interface and Ethernet. Special versions with E-Mark label (ECE requestion) are available upon request for vehicle application.

+ (A) (B) 1 2

3 4 5 6

7

DC INPUT

8 9 10 11

12 13 14 15

POWER

24V DC

MITSUBISHI

ESC

AL2-24MR-D

OK

100-240

VAC

L N

S/S X1

X0

X2

X3

X4

X5 X7

X6

IN

MITSUBISHI

POWER

RUN

ERROR

0V

24V

Y0

Y1

COM0 COM1COM2

Y3

Y4

Y5

OUT

0 1 2 3

4 5

14MR

-ES/UL

100-240

VAC L

N

S/S

X1

X0 X2

X3

X4

X5

X6

X7 X11 X13

X10 X12

MITSUBISHI

0 1 2 3

4 5 6 7

8 9 10 11

12 13 14 15

IN

POWER

RUN

ERROR

24+

0V

Y0

COM0

Y1 Y2

COM1 COM2

Y3

Y4

Y5 Y6

COM4

Y7

OUT

0 1 2 3

4 5 6 7

10 11

Y11

24MR

-ES/UL

Expandability and Power

The MELSEC FX family is highly flexible, enabling fast and efficient configuration and programming for the application at hand.

It is the ideal choice, no matter whether you need to install a simple control application requiring 30 I/Os (FX 1S ) or a demanding, complex system with up to

384 I/O points (FX 3U ).

The use of memory cassettes can expand the available programming space on some

FX Family PLCs while generally providing a long term program storage option for all

FX PLC users. In addition, memory cassettes can also allow programs to be switched at very short notice simply by replacing the cassette.

There are five series in the MELSEC FX family, each of which is designed for a different application profile:

앬 The FX

1S

Series

The MELSEC FX 1S series is the inexpensive entry to the MELSEC FX family. With its small dimensions it is also an excellent alternative to relay/contactor control configurations.

앬 The FX 1N Series

The CPUs of the FX 1N series offer more power than the FX 1S series, plus modular expansion capabilities. You can choose from I/O expansion modules and special function modules for a wide variety of applications.

앬 The FX

3G

Series

The FX3G is an introductory compact PLC and is the newest addition to the FX3 series, designed for simple yet performance-critical applications. Incorporating innovative FX3 series technology the customer is presented with a suite of benefits.

앬 The FX 3U Series

The FX 3U series gives you the freedom of modular expandability, with a wide selection of expansion modules and special function modules.

The FX 3U is the fastest PLC systems available, with a cycle time of just 0.065 μs per logical instruction. This gives users a powerful CPU delivering modular PLC performance in a compact PLC design.

앬 The FX 3UC Series

The performance of the FX 3UC is the same as that of the FX 3U series, but it has more compact dimensions. It is the ideal choice for applications where little space is available for the controller.

Thus the FX 3U and FX 3UC series give you the most powerful CPU for your application and combines all benefits of a compact PLC system with the performance of a modular PLC system.

FX

1S

No. of inputs/outputs

Program steps

FX 1N

FX 3G

FX /FX 3UC

Cycle time (µs)

* Available with optional cassette

4 MITSUBISHI ELECTRIC

SYSTEM

DESCRIPTION

///

Features

The modular design of the FX family makes it extremely flexible, enabling it to be used for a very broad range of applications.

You can configure tailor-made systems by combining modules from a variety of different categories (see figure).

All modules are electrically isolated from their environment with optocouplers for maximum reliability.

Communications modules

Interface modules with

RS232/RS422/RS485 interfaces for the connection of peripherals and PLC–PLC links.

Network modules for Ethernet,

Profibus/DP, CC-Link, AS-Interface, DeviceNet, CANopen and for the configuration of proprietary Mitsubishi networks

DIGITAL

INPUTS/OUTPUTS

COMMUNI-

CATIONS-

MODULES

KOMMUNI-

KATIONS-

MODULE

DIGITALE

EIN-/AUSGÄNGE CPU

ANALOG

INPUTS/

OUTPUTS

ANALOGE

EIN-/AUS-

GÄNGE

POSITIONING

MODULES

POSITIONIER-

MODULE

Digital I/O modules

For a variety of signal levels with relay or transistor switches

Positioning modules

High-speed counter modules with support for the connection of incremental rotary transducers and positioning modules for servo and stepping motor drives

Analog I/O modules

For processing current/voltage signals and temperature registration with a direct connection option for

PT100 resistance thermometers and thermocouplers

Digital and special function modules – configuration

The options for using digital and special function modules are dictated by the CPU used in the system.

When calculating the number of special function modules you can use in a system you must take both the number of digital modules and the maximum number of special function modules that can be used into account.

The table on the right provides a simplified guide to the number of modules you can use in each system type. More detailed information and the basic principles of system configuration can be found in the corresponding manuals.

FX1S

FX1N

FX3G

FX3U

FX3UC

MITSUBISHI ELECTRIC

Stand-alone PLC with 10 / 14 / 20 or 30 I/Os; no special function modules but 1 I/O adapter board can be installed

PLC with max. 132 I/Os

A maximum of 2 special function modules or digital expansion modules with up to

32 inputs and outputs (4x8 I/Os or 2x16 I/Os) or one special function module and one digital extension module with up to 16 inputs and outputs (2x8 I/Os or 1x16 I/Os) can be connected.

PLC with max. 256 I/Os

A maximum of 8 special function modules and digital extension modules with up to

128 I/Os can be connected to the right side of the main unit. In addition, a maximum of

4 special adapters from the FX3U series can be connected to the left side.

PLC with max. 384 I/Os

To the left side of the main unit, a maximum of 10 special adapters from the FX3U series can be connected. To the right side of the main unit, up to 8 special function modules and digital extension modules with up to 256 I/Os can be connected.

PLC with max. 384 I/Os

To the left side of the main unit, a maximum of 6 special adapters from the FX3U series can be connected. To the right side of the main unit, up to 4 special function modules and digital extension modules with up to 256 I/Os can be connected.

5

///

SYSTEM

DESCRIPTION

The Components for an FX PLC System

A basic FX PLC system can consist of a stand alone base unit, with the functionality and I/O range increased by adding extension I/O and special function modules. The following section provides an overview of options available.

Base Units

The entire FX PLC range can be AC or DC powered with a mix of input and output styles. The PLCs can be programmed with the user friendly GX or GX IEC Developer programming software, allowing programs to be transferred between different

FX PLCs. All PLC base units include an integrated real time clock.

Base units are available with different I/O configurations from 10 to 128 points but can be expanded to 384 points depending upon the FX range selected.

Extension Boards

Extension adapter boards can be installed directly into the base unit and therefore do not require any additional installation space. For a small number of I/O (2 to 4) an extension adapter boards can be installed directly into the (left-hand side) FX

1S

,

FX 1N , FX 3G or FX 3U controller. Interface adapter boards can also provide the FX

PLC with additional RS232, RS422, RS485 or USB interfaces. To connect special function modules (e.g. Ethernet module) a communication adapter has to be installed (except FX 3UC ).

Extension I/O Modules

Unpowered and powered extension I/O modules can be added to the FX 1N /FX 3U and FX 3UC PLCs.

For expansion modules powered by the base unit, the power consumption has to be calculated as the 5 V DC bus can only support a limited number of expansion I/O

(for further details please refer to next page

– calculation of the power consumption).

Special Function Modules

A wide variety of special function modules are available for the FX 1N , FX 3G , FX 3U and

FX

3UC

PLCs. They cover networking functionality, analog control, pulse train outputs, data logging function and temperature inputs.

Memory extension and operator terminals

Each FX family base unit can be equipped with a memory cassette. The programming unit interface enables the connection of programming tools like PC and hand held programming units as well as graphical operator terminals.

FX

0N

-3A

POWER

0

ON L

1 2

4

ATION

5 6 7

OFF

ON

8

9 A B C D E F

ERR

IN

ERROR STATION

OFF

ON

MOD 0 1 2 3

6

Extensions for inside

PLC installation

Extension modules

(installation outside the PLC)

Network modules

Communications boards

Communications modules

Dedicated function modules

Memory cassettes

External Display

Digital

Analog

Digital

Analog

Temperature

AS-Interface

CC-Link

CAN open

Ethernet

Profibus/DP

DeviceNet

Modbus RTU/ASCII

SSCNET

RS232

RS422

RS485

USB

RS232

RS485

High speed counter

Positioning

ALPHA2

FX1S

FX3G

FX1N

FX3U

FX3UC

Reference page

11, 45

11, 46

29

33

11, 34

12, 39

41

43

44

37

48

38

43

40

44

44

36

48

48

47

37

12, 49

54

� only via IEC function blocks

MITSUBISHI ELECTRIC

SYSTEM

DESCRIPTION

///

Calculation of the Power Consumption

The power consumption figures on the

5 V DC bus for the special function modules are shown in the specifications tables on the following pages.

The maximum permissible currents on the

5 V DC and 24 V DC bus are shown in the table below.

Modules Max. current

5 V bus

FX 3G -14/24M

-ES(ESS) —

FX 3G -40/60M

-ES(ESS)

FX 3U -16/32M

-ES(ESS)

500 mA

FX 3U -48–128M

-ES(ESS) 500 mA

FX3UC-16MT/D(DSS) 600 mA

FX3UC-32MT/D(DSS)

FX3UC-64MT/D(DSS)

FX3UC-96MT/D(DSS)

560 mA

480 mA

400 mA

24 V bus

400 mA

400 mA

400 mA

600 mA

The residual currents for the 24 V DC service voltage at different input/output configurations are shown in the tables on the right.

A maximum of 256 I/Os are possible for

FX3U/FX3UC (128 I/Os for FX3G).

Max. residual current values (in mA) for FX 3U -16M

-E

첸첸 through FX 3U -32M

-E

첸첸 for the permissible configuration

Number of additional outputs

40 25

32 100 50

8

0

24 175 125 75 25

16 250 200 150 100 50 0

325 275 225 175 125 75

0

25

400 350 300 250 200 150 100 50 0

0 8 16 24 32 40 48 56 64

Number of additional inputs

Max. residual current values (in mA) for FX 3U -48M

-E

첸첸 through FX 3U -128M

-E

첸첸 for the permissible configuration

Number of additional outputs

64 0

56 75 25

48 150 100 50 0

40 225 175 125 75 25

32 300 250 200 150 100 50

8

0

24 375 325 275 225 175 125 75 25

16 450 400 350 300 250 200 150 100 50 0

525 475 425 375 325 275 225 175 125 75

0

25

600 550 500 450 400 350 300 250 200 150 100 50 0

0 8 16 24 32 40 48 56 64 72 80 88 96

Number of additional inputs

An external power supply is necessary, if the residual current for the 24 V supply of the special function modules is not sufficiant.

Sample Calculations

The tables below and on the right show different examples for sample power calculation for a PLC system.

The current values for the special function modules can be found in the specifications on the following pages.

Comparison with the current value tables show that the calculated figures for the

5 V bus lie within the allowable ranges.

In the example below all units can be supplied sufficiently with the internal

24 V power supply.

Module

FX3U-80MR/ES

FX3U-4AD

FX3U-4DA

FX3U-ENET

No.

1

3

2

1

24 V DC calculation

Current / module

600 mA

Calculation

+600 mA

90 mA

160 mA

240 mA

-180 mA

-320 mA

-240 mA

-140 mA !!!

An external 24 V power supply has to be added in the example above.

5 V DC calculation

Current / module

+500 mA

Total current

+500 mA

110 mA

120 mA

Result:

-220 mA

-240 mA

500 – 460 mA

40 mA (OK !)

Module

FX3U-48MR/ES

FX2N-16EYR-ES/UL

FX2N-8EX-ES/UL

FX2N-8EYR-ES/UL

FX3U-4AD-PT-ADP

FX2N-32ER-ES/UL

FX2N-16EX-ES/UL

FX2N-10PG

FX2N-32CCL

No.

1

1

1

1

Result:

1

1

1

1

1

16

16

8

X

24

Number of I/Os

8

Y

24

16

16

64 + 64 + 16 = 144! (< 256) OK!

8

8

X/Y

— X = 8

Y = 24

X = 16

Y = 0

24 V DC calculation

Total

Total current

+325 mA

-50 mA

+275 mA (OK!)

+150 mA residual current for extension unit

FX2N-32ER-ES/UL

0 mA

-50 mA

+100 mA (OK!)

5 V DC calculation

Current / module

500 mA

30 mA

690 mA

120 mA

130 mA

Total current

+500 mA

0 mA

0 mA

0 mA

-15 mA

+485 mA (OK!)

+690 mA

0 mA

-120 mA

-130 mA

+440 mA (OK!)

Total no. of I/Os which are connected to a base unit to calculate the max. residual current values (see tables)

햳 see tables above (max. residual current values)

MITSUBISHI ELECTRIC 7

///

ALPHA

SYSTEM

OUTLINE

1

The ALPHA 2 Series

Up to 15 inputs can be used as digital inputs and up to for (controllers with 24 V DC supply).

The analog inputs (0–10 V, 9 bits resolution) can be used very easily due to the integrated gain function and a

Schmitt-trigger.

The communication with a computer and with external peripherals is supported by the two integrated serial interfaces .

Integrated calender/real-time function with up to 1200 switch ON or OFF commands in one program

+ -

(A)

(B) 1

2

3 4

5

6 7

DC INPUT

8

9 10

11

12 13

14

15

POWER

24V DC

ESC

OK

MITSUBISHI

Direct programming via

8 function keys on the front control panel without any additional programming device

The units can be expanded to additional inputs/outputs with extension modules to be mounted directly into the controller

AL2-24MR-D

Flexible mounting through integrated

DIN rail adapter and screw fixing

Large LC display for programming, entering, and editing plain text, values and bar graphs

Password protection can be activated.

The program is stored in a maintenancefree EEPROM with a memory capacity of

5000 bytes.

A backup battery is not required.

Description of the Unit Components

Power supply terminals

Mounting hole

+ (A) (B)

1

2

3 4

5

6 7

DC INPUT

8

9 10

11

12 13

14

15

Adapter for

DIN rail mounting

Slot for

EEPROM cassette or connector for programming cable

POWER

24V DC

ESC

OK

AL2-24MR-D

Protective cover

LCD display

(4 lines x 12 characters)

MITSUBISHI

Terminals for digital/analog inputs

Connector for PC,

GSM, modem and other automation components

Operating keys (8 pcs.)

Housing cover

(place holder) for the extension modules

8

Connection for extensions

Terminals for digital outputs

MITSUBISHI ELECTRIC

ALPHA

BASE

UNITS

///

Specifications ALPHA 2

+ -

(A)

(B) 1

2

3 4

5 6

7

DC INPUT

8 9

10 11

12 13

14 15

POWER

24V DC

MITSUBISHI

ESC

OK

AL2-24MR-D e.g. AL2-24M

-

ALPHA 2 Base Units

The ALPHA 2 controllers offer simple reliable control for a range of automation applications including lighting, air conditioning, security systems, and temperature and water control.

Special features:

Transistor and relay output options

Analog input/output

High Speed counters up to 1 kHz

GSM function for communication with mobile phones

Language support for 8 different languages

Display unit for messages and function block data

1

Base Units with 10–24 I/Os

AL2-10MR-D AL2-14MR-A AL2-14MR-D AL2-24MR-A AL2-24MR-D

Electrical specifications

Integrated inputs/outputs

Power supply

Digital inputs

Analog inputs

Channels

Integrated outputs

Max. power consumption

Typ. power consumption

Weight

All I/Os

ON /OFF

Dimensions (WxHxD)

Order information

Accessories

4

10

100–240 V AC

6

W 4.9

10

24 V DC

6

6

6

4

14

100–240 V AC

8

6

14

24 V DC

8

8

8

6

24

100–240 V AC

15

9

24

24 V DC

15

8

8

9 kg 0.2

mm 71.2x90x55

Art. no. 215070

4.0

2.5/0.75

0.2

71.2x90x55

215071

5.5

4.5/2.0 240 V AC

3.5/1.5 120 V AC

0.3

124.6x90x52

215072

7.5

4.0/1.0

0.3

124.6x90x52

215073

7.0

5.5/2.5 240 V AC

4.5/2.0 120 V AC

0.35

124.6x90x52

215074

Power supplies with DIN-rail or wall mounting possibilities for powering the 24 V DC modules (refer to the power supply chapter in this catalogue)

9.0

5.0/1.0

0.3

124.6x90x52

215075

MITSUBISHI ELECTRIC 9

///

GENERAL

SPECIFICATIONS

1

Environmental Specifications

Ambient temperature

Protection rating

Noise immunity

Dielectric withstand voltage

Allowable relative humidity

Shock resistance

Vibration resistance direct mounting

DIN rail mounting

Insulation resistance

Ambient conditions

Certifications

Display: -10–55 °C, Hardware: -25–55 °C (storage temperature: -30–+70 °C)

IP20

1000 Vpp with noise generator; 1 µs at 30–100 Hz, tested by noise simulator

3750 V AC, >1 min. according to EN60730

35–85 % (no condensation)

Acc. to IEC 68-2-27: 147 m/s

2 acceleration, 11 ms 3x3 directions

Acc. to IEC-2-6: 19.6 m/s

2 acceleration, 80 min. in each direction

Acc. to IEC-2-6: 9.8 m/s 2 acceleration, 80 min. in each direction

500 V DC, 7 M

W acc. to EN60730-1

No corrosive gases, no dust

Please refer to pages 66–67 in this catalogue

Electrical Specifications

Power supply

Inrush current at ON

24 V DC

£

7.0 A (at 24 V DC)

Allowable momentary power failure time 5 ms

Digital Inputs

Input voltage

Input current

Response time

OFF

ON

®

®

ON

OFF

100–240 V AC (50/60 Hz)

£

6.5 A (at 240 V AC)

10 ms

24 V DC

(+20 %/-15 %)

100–240 V AC

(+10 %/-15 %), 50/60 Hz

The input current changes depending on Source or Sink.

For Sink:

(AL2-10/14/24MR-D)

= 5.5 mA, 24 V DC

For Source:

(AL2-10/14MR-D)

= 6.0 mA, 24VDC

(AL2-24MR-D)

= 5.5 mA, 24 V DC

I01–I08

0.13 mA/120 V AC*

0.25 mA/240 V AC*

I09–I15

0.15 mA/120 V AC*

0.29 mA/240 V AC* ms 10–20 ms 10–20

35–85 ms, 120 V AC

25–55 ms, 240 V AC

35–85 ms, 120 V AC

50–130 ms, 240 V AC

Analog Inputs

Analog input range

Resolution

Conversion speed

Voltage

Impedance

Accuracy

0–500

9 bit, (10 V/500) ms 8

0–10 V DC k

W

142 ±5 %

±5 % (0.5 V DC)

* Current leakage from the sensors connected to the inputs might provide enough current to turn the controller On. Do not use two wire sensors

Type

Switching voltage (max.)

Rated current

Max. switching load

Minimum load

Response time

- inductive load

Type

Relay

V 250 V AC, 30 V DC

10M, 14M: 8 A/point

24M (001-004): 8 A/point

24M (005-009): 2 A/point

14M, 24M:249 VA, 250 V AC/373 VA, 250 V AC

24M: 93 VA, 125 V AC/93 VA, 250 V AC

10 mA, 5 V DC ms

£

10

Programming Specifications

Programming method

Program capacity

Program processing

Number of available instructions

Program storage

Data storage

Processing time

Real-time clock

Program protection

Function block

200 function blocks or 5000 bytes

Cyclic processing of the stored program

38 different function blocks

Integrated EEPROM and optional additional EEPROM cassette

At voltage loss the current status of values, running time meters, and real-time data are stored for up to 20 days (at temperatures of 0 to 25 °C) through integrated capacitors

1 ms + 20 m s/log. instruction (complex commands 500 m s/instruction)

Seconds, minutes, hours, day of week, month, year (4-digit); accuracy: 5 s/day; automatic summer and winter time toggling

Program and keys (3 levels)

10 MITSUBISHI ELECTRIC

EXTENSION

MODULES

///

RELAY

OUTPUT

EO1

EO2

MITSUBISHI

EO3

EO4

4EYR

Digital Extension Modules

There are 4 different extension modules available for the ALPHA 2, which allow the controller to be extended through additional inputs or outputs. The modules are inserted directly into the ALPHA 2 and therefore do not take up any additional space.

The AL2-4EX has the additional feature that 2 inputs may be used as high-speed counters with a counting frequency of 1 kHz.

All modules feature photocoupler insulation for all I/Os.

Note: The digital extension modules cannot be used with the AL2-10MR series.

1

AL2-4EX AL2-4EYR AL2-4EYT

Inputs

Integrated inputs

Input voltage

Input current

4

220–240 V AC

7.5 mA at 240 V AC (50 Hz),

9.0 mA at 240 V AC (60 Hz)

Outputs

Integrated outputs

Output type

Switched voltage (max.)

Rated current

V —

A —

Electrical specifications

Power Supply AC range (+10 %, -15 %) 220–240 V AC

Mechanical specifications

Weight kg 0.05

Dimensions (WxHxD) mm 53.1x90x24.5

4

24 V DC (+20 %, -15 %)

5.4 mA ±1 mA at 24 V DC

24 V DC

0.05

53.1x90x24.5

4

Relay

250 V AC, 30 V DC

2 A per output

100–240 V AC

0.05

53.1x90x24.5

4

Transistor

5–24 V DC

1 A per output

24 V DC

0.05

53.1x90x24.5

Order information Art. no. 142522 142521 142523 142524

Note: EI1 and EI2 of the AL2-4EX can be used as high-speed counter inputs. In each case the response time for the high-speed counter inputs will be 0.5 ms or less.

The AL2-4EX-A2, AL2-4EX, AL2-4EYR and AL2-4EYT modules can not be used with the AL2-10MR series.

+ V1+ V1-

V2+ V2-

POWER

24V DC

CH1

OUTPUT

CH2

0~10V

MITSUBISHI

POWER

450°C

CH1

-50°C Line

450°C

CH2

-50°C

Line

AL2-2TC-ADP

K-type Thermocouple

-50~450°C

CH1

CH2

L1+

L1SLD L2+

L2SLD

+ V1+ V1-

V2+ V2-

POWER

24V DC

CH1

OUTPUT

CH2

0~10V

MITSUBISHI

POWER

200°C

CH1

-50°C Line

200°C

CH2

-50°C

Line

AL2-2PT-ADP

PT100 -50~200°C

CH1

CH2

L1+

L1L2+

L2-

I

2-

POWER

24V DC

+

V1+ I1+

VI1-

ANALOG

OUTPUT

MITSUBISHI

ANALOG

OUTPUT

V2+ I2+

VI2-

2DA

Analog Extension Modules

The analog extension modules significantly increase the range of applications for the

ALPHA 2. With these modules it is possible to output voltage or current signals or to measure temperatures.

Three different analog extension modules are available:

앬 The AL2-2DA offers two additional analog outputs for the ALPHA 2 and converts a digital input value into a voltage or a current. This module is inserted directly into the

ALPHA 2.

Note: the AL2-2DA cannot be used with the AL2-10MR series.

앬 The AL2-2PT-ADP connects an external PT100 sensor to convert temperature readings into analog signals (0–10 V).

앬 The AL2-2TC-ADP connects thermocouple sensors (K type) to convert temperature readings into analog signals (0–10 V).

Analog inputs

Integrated inputs

Connectable temperature sensors

Compensated range

Analog outputs

Integrated outputs

Analog output range voltage current

Electrical specifications

Number of channels

Power Supply

Mechanical specifications

Weight

Dimensions (WxHxD)

Order information

2

0–10 V DC (5 k

1 M

)

4–20 mA (max. 500

)

2

24 V DC (-15–+10 %), 70 mA kg 0.05

mm 53.1x90x24.5

Art. no. 151235

AL2-2PT-ADP

2

PT100 sensor

Temp. coefficient 3.850 ppm/°C (IEC 751)

-50–+200 °C

2

24 V DC (-15–+20 %), 1 W

0.07

35.5x90x32.5

151238

AL2-2TC-ADP

2

Thermocouple (K type), isolated type

(IEC 584-1 1977, IEC 584-2 1982)

-50–+450 °C

2

24 V DC (-15–+20 %), 1 W

0.07

35.5x90x32.5

151239

MITSUBISHI ELECTRIC 11

///

EXTENSION

MODULES

AND

ACCESSORIES

1

12

MITSUBISHI ELECTRIC

ASI

+

ASI

-

ASI

+

ASI

-

AS-Interface Module AL2-ASI-BD

The Actuator Sensor Interface module AL2-ASI-BD in combination with an ALPHA 2 controller facilitates the data communications via an AS-Interface system. The AL2-ASI-BD is attached to an ALPHA 2 series module and forms a slave unit. Up to 4 inputs and 4 outputs can be exchanged with the AS-Interface master.

The addresses of the slave devices in the AS-Interface are assigned either automatically via the master in the network or via a programming device (software).

The maximum communication distance is 100 m without a repeater. If 2 repeaters are used, the distance is extended to up to 300 m.

For the AS-Interface a separate power supply is required. The communication signal is superimposed on the power supply of the AS-Interface bus.

Note: The AL2-ASI-BD cannot be used with the AL2-10MR series.

Module type

Number of I/O points

External power supply

External current consumption

Communications protocol

Weight

Dimensions (WxHxD)

Order information

Slave module

4 inputs, 4 outputs

30.5 V DC (AS-Interface power supply) mA Max. 40

AS-Interface standard kg 0.05

mm 53.1x90x24.5

Art. no. 142525

Memory Cassette AL2-EEPROM-2 Memory Media

With the AL2-EEPROM-2 memory cassettes, a new program can be transferred to the

ALPHA 2 controller’s internal system memory from the cassette, or the program of the internal system memory can be saved to the cassette.

If the memory cassette is used, a certain program can be run temporarily by simply plugging the external memory module onto the ALPHA 2.

After removing the memory cassette, the former program in the internal memory becomes active again.

The memory cassette AL2-EEPROM-2 is not a memory expansion device, but a medium for data exchange.

Memory type

Application

Memory capacity

Function blocks

Dimensions (WxHxD)

Order information

EEPROM

ALPHA 2

5,000 bytes

Max. 200 mm 10x45x25

Art. no. 142526

AL-232CAB

Interface Cable AL-232CAB

The AL-232CAB is an RS232C interface cable. It connects the ALPHA 2 controller to a personal computer running the programming software for the ALPHA 2 controller.

The cable ensures a galvanic isolation between the ALPHA 2 controller and the personal computer. The cable AL-232CAB can not be used for any other connection.

GSM Cable AL2-GSM-CAB

The GSM AL2-GSM-CAB is an RS232C interface cable and it is used to connect the

ALPHA 2 controller to a normal or GSM modem, a personal computer or other serial devices. It can transfer SMS data to a GSM modem for onward transmission to mobile telephones or e-mail addresses. It also permits remote monitoring and remote maintenance.

Note: The above cables cannot be used with the AL2-10MR series.

AL2-GSM-CAB

Connector

Application

Length

Order information

9-pin D-SUB female connector

ALPHA 2 <-> PC m 2.5

Art. no. 87674

9-pin D-SUB male connector

ALPHA 2 <-> PC, modem

1.5

142528

MITSUBISHI ELECTRIC

BASE UNITS

FX1S SERIES

///

The MELSEC FX 1S Series

All units feature two

RUN/STOP switch .

Integration of analog potentiometer for setpoint value entry and an integrated interface, extension, and functions adapters for direct installation in the base unit

High-speed inputs for fast counting tasks with counting frequencies of up to 60 kHz and capabilities interrupt processing

MITSUBISHI

MELSEC

0 1

2 3

4 5

6 7

IN

POWER

ERROR

FX1S-14MR

OUT

0 1

2 3

4 5

The internal service power supply unit for 24 V DC has a capacity of 400 mA.

Note: service power supply is only available for AC Power

Supply types.

Square pulse output

(this applies only to transistor units.)

Two high speed pulse outputs for frequencies up to

100 kHz for outputting and controlling stepping motors

Integrated real-time clock with year, month, day and time

Integrated serial RS422 interface for direct communication with computers

Flexible installation with the integrated DIN rail adapter and screw fastening holes for mounting on flat surfaces

Password access protection facility for effective protection of your intellectual property.

Your PLC programs are stored in a maintenance-free EEPROM user memory with a capacity of 2,000 program steps, so there is no need for a backup battery to protect against power failures.

2

Description of the Unit Components

Fixing hole

Connection of the power supply

Adapter interface

Slot for adapter

2 analog potentiometers

Connection for programming units

Service voltage source

Terminals for digital outputs

100-240

VAC

L

N

S/S

X0

X1

X2

X3

X4

X5

X6

X7

0 1 2 3

4 5 6 7

IN

POWER

RUN

ERROR

Y0

Y1

Y2

24V

0V

COM0 COM1COM2

Y3

Y4

Y5

OUT

0 1 2 3

4 5

14MR

-ES/UL

MITSUBISHI

Protective cover

Terminal cover

Terminals for digital inputs

LEDs for indicating the input status

RUN/STOP switch

LEDs for indicating the operating status

LEDs for indicating the output status

Housing cover

MITSUBISHI ELECTRIC 13

2

///

BASE UNITS

FX1S SERIES

Base Units

100-240

VAC

L

N

S/S

X0

X1

X2

X3

X4

X5

X6

X7

0 1 2 3

4 5 6 7

IN

MITSUBISHI

POWER

RUN

ERROR

24V

0V

Y0 Y1

COM0 COM1COM2

Y2

Y3

Y4

Y5

OUT

0 1 2 3

4 5

14MR

-ES/UL

þ FX 1S

¨ FX 1N

¨ FX 3G

¨ FX 3U

¨ FX 3UC

Base Units FX 1S

The FX 1S series base units are available with 10 to 30 input/output points.

It is possible to choose between relay and transistor output type.

Note: Versions with UL certification are available on request.

Special Features:

Integrated power supply (AC or DC powered)

Maintenance-free EEPROM memory

Ample memory capacity (2000 steps) and device ranges

High-speed operations

Incorporated positioning control

Integrated real-time clock

System upgrades by exchangeable interface and I/O adapter boards for direct fitting into the base unit

LEDs for indicating the input and output status

Standard programming unit interface

User-friendly programming systems, including IEC 61131.3

(EN 61131.3)-compatible programming software, HMIs and hand-held programming units

Base Units with 10–14 I/Os

Max. number inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

6

4

10

24 V DC

Relay

W 6 kg 0.22

mm 60x90x49

Art. no. 141240

FX1S-10

MR-ES/UL

6

4

10

100–240 V AC

Relay

19

0.3

60x90x75

141243

FX1S-10

MT-DSS

10

24 V DC

6

4

Transistor

(source)

6

0.22

60x90x49

141246

FX1S-14

MR-DS

8

6

14

24 V DC

Relay

6.5

0.22

60x90x49

141247

FX1S-14

MR-ES/UL

8

6

14

100–240 V AC

Relay

19

0.3

60x90x75

141248

FX1S-14

MT-DSS

14

24 V DC

8

6

Transistor

(source)

6.5

0.22

60x90x49

141249

Base Units with 20–30 I/Os

Max. number inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

20

24 V DC

12

8

Relay

W 7 kg 0.3

mm 75x90x49

Art. no. 141251

FX1S-20

MR-ES/UL

20

100–240 V AC

12

8

Relay

20

0.4

75x90x75

141252

FX1S-20

MT-DSS

20

24 V DC

12

8

Transistor

(source)

7

0.3

75x90x49

141254

FX1S-30

MR-DS

30

24 V DC

16

14

Relay

8

0.35

100x90x49

141255

FX1S-30

MR-ES/UL

30

100–240 V AC

16

14

Relay

21

0.45

100x90x75

141256

FX1S-30

MT-DSS

30

24 V DC

16

14

Transistor

(source)

8

0.35

100x90x49

141257

14 MITSUBISHI ELECTRIC

BASE UNITS

FX1S SERIES

///

Base Units

Environmental Specifications

Ambient temperature

Protection

Noise durability

Dielectric withstand voltage

Ambient relative humidity

Shock resistance

Vibration resistance

Insulation resistance

Ground

Fuse rating

Environment

Certifications

þ FX 1S

¨ FX 1N

¨ FX 3G

¨

0–55 °C (storage temperature: -20–+70 °C)

IP10

1000 Vpp with noise generator; 1 µs at 30–100 Hz

1,500 V AC, 1 min. (500 V AC for direct voltage modules)

35–85 % (non-condensing)

Acc. to IEC/EN 68-2-27: 15G (3 times each in 3 directions for 11 ms)

Acc. to IEC/EN 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting

500 V DC, 5 M

W

Class D: Grounding resistance 100

W or less

AC models: 250 V 1.0 A; DC models: 0.8 A

Avoid environments containing corrosive gases, install in a dust-free location.

Please refer to pages 66–67 in this catalogue

FX 3U

¨ FX 3UC

2

Electrical Specifications

Power supply 24 V DC (+10 %/-15 %)

Inrush current at ON 10 A/0.1 ms (at 24 V DC)

Allowable momentary power failure time

Primary power supply

5 ms

24 V DC, 400 mA

External power supply (24 V DC) —

100–240 V AC (+10 %/-15 %),

50/60 Hz (±10 %)

15 A/5 ms (at 100 V AC);

25 A/5 ms (at 200 V AC)

10 ms

400 mA

Switching voltage (max.)

Max. output current

Max. switching current

Response time

- per output

- per group*

- inductive load

- lamp load

Life of contacts (switching times)**

Type

Transistor modules

V <250 V AC, <30 V DC 5–30 V DC

A 2 0.5

A 8

80 VA

W 100 ms 10

0.8

12 W

1.2

0.2

3,000,000 at 20 VA; 1,000,000 at 35 VA;

200,000 at 80 VA

* The limitation applies only per reference terminal for each group, 1 and 4 outputs for relays and transistors. Please observe the terminal assignments for the group identification.

** Not guaranteed by Mitsubishi Electric.

Programming Specifications

Program data

Program memory

Program execution

Program protection

Number of instructions

Cycle period

Operands

Internal relays

Special relays

State relays

Timers

External setpoint entry via potentiometer

Counter

High-speed counter inputs

Data register

Index register

Special register

Pointer

Nesting operands

Interrupt inputs

Constants

2.000 steps EEPROM (internal)

Periodical execution of the stored program

Password protection with 3 protection levels. Note: Protection levels may only be changed with FX-10P/FX-20P/FX-30P.

27 sequence instructions, 2 step ladder instructions, 85 applied instructions

0.55–0.7 µs/logical instruction

512 total, with 384 general (M0–M383) and 128 latched (M384–M511)

256 (M8000–M8255)

128

64 (max. 63 timers, partially switchable to 100 ms and 10 ms)

2 potentiometers

32 (16 bit), C0–C31

1 phase, 6 points max: 60kHz/2 points, 10kHz/4 points ; 2 phase, 2 points max: 30kHz/1 point, 5kHz/1 point

256 subtotal (128 general (D0–D127) and 128 latched (D128–D255))

16

256 (16 bit), D8000–D8255

64, P0–P63

8, N0–N7

6

16 bits: K: -32768 to +32767, hex: 0–FFFF

32 bits: K: -2147483648 to +2147483647, hex: 0–FFFF FFFF

MITSUBISHI ELECTRIC 15

///

BASE UNITS

FX1N SERIES

The MELSEC FX 1N Series

High-speed inputs for fast counting tasks with counting frequencies of up to 60 kHz and interrupt processing capabilities

2

Integration of for direct installation in the base unit

The base units have integrated, maintenance-free EEPROM user memory for up to 8,000

PLC program steps, so there is no need for a backup battery to protect against power failure.

You can also configure password protection to prevent unauthorized access to your programs.

Integrated RUN/STOP switch and two analog potentiometers for setpoint value entry.

MITSUBISHI

MELSEC

0

4

1

10

2

5

11

14

3

6

12

7

13

15

IN

RUN

ERROR

FX1N-24MR

2

0

4

3

1

5

10

11

6

7

The base units can be expanded for up to 128 inputs/outputs with different extension units .

Integrated real-time clock with year, month, day and time

External EEPROM memory cassettes for PLC program storage

Square pulse output

(This only applies for transistor units.)

Two i ntegrated high-speed pulse outputs for frequencies up to

100 kHz for outputting pulse signals and controlling stepping motors

Description of the Unit Components

Terminal cover

Fixing hole

RUN/STOP switch

Slot for memory cassettes, displays and ADPs.

2 analog potentiometers

Connection for programming units

Terminals for service voltage source

Terminals for digital outputs

Terminal cover

Protective cover

100-240

VAC

L

N

S/S

X0

X1

X2

X3

X4

X5

X6

X7 X11 X13

X10 X12

X15

X14

0 1 2 3

4 5 6 7

8 9 10 11

12 13 14 15

IN

POWER

RUN

ERROR

OUT

24+

0V

Y0

COM0

Y1

Y2

COM1 COM2

Y3

COM3

Y4

Y5

Y6

COM4

Y10

Y7

0 1 2 3

4 5 6 7

10 11

Y11

24MR

-ES/UL

MITSUBISHI

16

Protective cover

Terminals for digital inputs

Connection of the power supply

Extension bus

LEDs for indicating the input status

LEDs for indicating the operating status

LEDs for indicating the output status

Housing cover

Lid

MITSUBISHI ELECTRIC

Base Units

100-240

VAC

L N

S/S

X0

X1

X2

X3

X4

X5

X6

X7

X11 X13

X10

X12

X15

X14

0 1 2 3

4 5 6 7

MITSUBISHI

8 9 10 11

12 13 14 15

IN

POWER

RUN

ERROR

OUT

0 1 2 3

4 5 6 7

10 11

24+

0V Y0

COM0

Y1

Y2

COM1

COM2

Y3

COM3

Y4

Y5

Y6

COM4 Y7

Y10

Y11

24MR

-ES/UL

BASE UNITS

FX1N SERIES

///

¨ FX 1S

þ FX 1N

¨ FX 3G

¨ FX 3U

¨ FX 3UC

Base Units FX 1N

The FX 1N series base units are available with 14 to 60 input/output points.

It is possible to choose between relay and transistor output type.

Note: Versions with UL certification are available on request.

Special Features:

앬 Integrated serial interface for communication between

Personal computers and HMI

Standard programming unit interface

LEDs for indicating the input and output status

Detachable terminal blocks for units with 14, 24, 40, and 60 I/Os.

Slot for memory cassettes

All DC models with variable voltage from 12 up to 24 V

Integrated real-time clock

Exchangeable interface and I/O adapter boards for direct fitting into the base unit

2

Base Units with 14–24 I/Os

Specifications

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

FX1N-14

MR-DS

8

6

14

12–24 V DC

Relay

Power consumption

Weight

Dimensions (WxHxD)

Order information

W 13 kg 0.45

mm 90x90x75

Art. no. 141258

FX1N-14

MR-ES/UL

8

6

14

100–240 V AC

Relay

29

0.45

90x90x75

141259

FX1N-14

MT-DSS

14

12–24 V DC

8

6

Transistor

(source)

13

0.45

90x90x75

141260

FX1N-24

MR-DS

24

12–24 V DC

14

10

Relay

15

0.45

90x90x75

141261

FX1N-24

MR-ES/UL

24

100–240 V DC

14

10

Relay

30

0.45

90x90x75

141262

FX1N-24

MT-DSS

24

12–24 V DC

14

10

Transistor

(source)

15

0.45

90x90x75

141263

Base Units with 40–60 I/Os

Specifications

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

FX1N-40

MR-DS

40

12–24 V DC

24

16

Relay

Power consumption

Weight

Dimensions (WxHxD)

Order information

W 18 kg 0.65

mm 130x90x75

Art. no. 141264

FX1N-40

MR-ES/UL

40

100–240 V AC

24

16

Relay

32

0.65

130x90x75

141265

FX1N-40

MT-DSS

40

12–24 V DC

24

16

Transistor

(source)

18

0.65

130x90x75

141266

FX1N-60

MR-DS

60

12–24 V DC

36

24

Relay

20

0.8

175x90x75

141267

FX1N-60

MR-ES/UL

60

100–240 V AC

36

24

Relay

35

0.8

175x90x75

141268

FX1N-60

MT-DSS

60

12–24 V DC

36

24

Transistor

(source)

20

0.8

175x90x75

141269

MITSUBISHI ELECTRIC 17

///

BASE UNITS

FX1N SERIES

2

Base Units

Environmental Specifications

Ambient temperature

Protection

Noise durability

Dielectric withstand voltage

Ambient relative humidity

Shock resistance

Vibration resistance

Insulation resistance

Ground

Fuse rating

Environment

Certifications

¨ FX 1S

þ FX 1N

¨ FX 3G

¨ FX 3U

0–55 °C (storage temperature: -20–+70 °C)

IP10

1000 Vpp with noise generator; 1 µs at 30–100 Hz

1,500 V AC, 1 min. (500 V AC for direct voltage modules)

35–85 % (non-condensing)

Acc. to IEC 68-2-27: 15G (3 times each in 3 directions for 11 ms)

Acc. to IEC 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting

500 V DC, 5 M

W

Class D: Grounding resistance 100

W or less

AC units: From FX1N-14M

첸 to FX1N-24M

: 250 V AC 1.0 A; From FX1N-40M

첸 to FX1N-60M

: 250 V AC 3.15 A/DC units: 125 V DC 3.15 A

Avoid environments containing corrosive gases, install in a dust-free location.

Please refer to pages 66–67 in this catalogue

¨ FX 3UC

Electrical Specifications

Power supply 12–24 V DC (+20 %/-15 %)

Inrush current at ON

25 A/1 ms (at 24 V DC);

22 A/0.3 ms (at 12 V DC)

Allowable momentary power failure time

5 ms

Primary power supply 24 V DC, 400 mA

External power supply (24 V DC) —

100–240 V AC (+10 %/-15 %),

50/60 Hz (±10 %)

30 A/5 ms (at 100 V AC);

50 A/5 ms (at 200 V AC)

10 ms

400 mA

Switching voltage (max.)

Max. output current

Max. switching current

Response time

- per output

- per group

- inductive load

Life of contacts (switching times)*

* Not guaranteed by Mitsubishi Electric.

Type

Transistor modules

V <240 V AC, <30 V DC 5–30 V DC

A 2

A 8

0.5

0.8

80 VA 12 W ms 10 <0.2(Y0, Y1<5µs)

3,000,000 at 20 VA; 1,000,000 at 35 VA;

200,000 at 80 VA

Programming Specifications

Program data

I/O points (addresses)

Address range

Program memory

Cycle period

Number of instructions

128 (+4 optional)

Max.128 inputs X0–X177, max. 128 outputs Y0–Y177

8,000 steps EEPROM (internal), exchangeable

EEPROM for easy program exchange

0.55–0.7 µs /logical instruction

27 sequence instructions, 2 step ladder instructions,

89 applied instructions

Programming language

Program execution

Program protection

Step ladder, instruction list, SFC

Cyclical execution, refresh mode processing

Password protection with 3 protection levels*

* Protection levels may only be changed with FX-10P/FX-20P/FX-30P.

Operands

Internal relays

Special relays

Step ladder

Timer

Ext. preset value via potentiometer

Counter

High-speed counter

Real-time clock

Data register

File register

Index register

Special register

Pointer

Nestings

Interrupt inputs

Constants

1,536

256

1,000

256

2

235

1 phase, 6 points max: 60kHz/2 points, 10kHz/4 points;

2 phase, 2 points max: 30kHz/1 point, 5kHz/1 point

Year, month, day, hour, minute, second, weekday

8,000

Max. 7,000 (parameter editable),

Total registers = 8,000

16

256

128

8

6

16 bits: K: -32768 to +32767, hex: 0–FFFF; 32 bits:

K: 2147483648 to +2147483647, hex: 0–FFFF FFFF

18 MITSUBISHI ELECTRIC

BASE UNITS FX3G SERIES ///

The MELSEC FX 3G Series

Integrated high-speed counter inputs for processing fast input signals. For example, you can configure two 60 kHz counters and four 10 kHz counters.

Interrupt processing is also handled via the inputs.

Add-in function boards can be installed in the PLC to provide a second RS485/

RS422/RS232 communications interface for programming or network configurations.

Analog function boards for input and output and a function board with

8 analog potentiometers are also available as add-in.

An integrated RUN/STOP switch is available.

Connection possibility for special function adaptermodules

Two integrated serial interfaces for direct communication with computers.

Description of the Unit Components

RAM/EEPROM memory for up to

32,000 PLC program steps gives you plenty of reserve, even for big, complex applications.

The base units can be expanded to provide configurations with up to 256 inputs and outputs with modular and compact extension units .

2

Integrated real-time clock with year, month, day and time

Two integrated pulse outputs for frequencies from 2 to 100,000 Hz for controlling stepping motors and outputting pulse-width modulated signals .

Memory cassette, display module, and expansion board connector

2 analog potentiometers

RUN/STOP switch

Option battery holder

Programming port: RS-422

Programming port: USB

Flip cover for programming port, potentiometer and

Run/Stop switch

Top cover

Terminal cover

Terminal protector

Input terminals

Input indicator LEDs

Operation status indicator

LEDs

Expansion bus connector cover

Output indicator LEDs

Output terminals

Terminal protector

Terminal cover

Protective cover

MITSUBISHI ELECTRIC 19

///

BASE UNITS

FX3G SERIES

2

Base Units ¨ FX 1S

¨ FX 1N

þ FX 3G

¨ FX 3U

¨ FX 3UC

Base Units FX 3G

The FX 3G series base units are available with 14 to 60 input/output points .

It is possible to choose between relay and transistor output types.

Special features:

Integrated USB interface for communication between PLCs and PC

Integrated serial interface for communication between PCs and HMI

LEDs for indicating the input and output status

Detachable terminal blocks for all units

Slot for memory cassettes

Integrated real-time clock

Integrated positioning control

Exchangeable interface and extension adapters for direct mounting into a base unit

Expandable with digital I/O modules, special function modules and ADP modules

User-friendly programming systems, including IEC 1131.3

(EN 61131.3) compatible programming software, HMIs and hand-held programming units

Base Units with 14–24 I/Os

Specifications

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

FX3G-14

MR/ES

14

FX3G-14

MT/ESS

14

100–240 V AC 100–240 V AC

8 8

6

Relay

6

Transistor

(source)*

W 31 kg 0.50

mm 90x90x86

31

0.50

90x90x86

Art. no. 231466

* Sink type transistor output units on request.

231470

FX3G-14

MR/DS

14

24 V DC

8

6

Relay

19

0,50

90x90x86

231474

FX3G-14

MT/DSS

14

24 V DC

8

6

Transistor

(source)*

19

0,50

90x90x86

231478

FX3G-24

MR/ES

24

100–240 V AC

14

10

Relay

32

0.55

90x90x86

231467

FX3G-24

MT/ESS

24

100–240 V AC

14

10

Transistor

(source)*

32

0.55

90x90x86

231471

FX3G-24

MR/DS

24

24 V DC

14

10

Relay

21

0,55

90x90x86

231475

FX3G-24

MT/DSS

24

24 V DC

14

10

Transistor

(source)*

21

0,55

90x90x86

231479

Base Units with 40–60 I/Os

Specifications

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

FX3G-40

MR/ES

40

FX3G-40

MT/ESS

40

100–240 V AC 100–240 V AC

24 24

16

Relay

16

Transistor

(source)*

W 37 kg 0.70

mm 130x90x86

37

0.70

130x90x86

Art. no. 231468

* Sink type transistor output units on request.

231472

FX3G-40

MR/DS

40

24 V DC

24

16

Relay

25

0,70

130x90x86

231476

FX3G-40

MT/DSS

40

24 V DC

24

16

Transistor

(source)*

25

0,70

130x90x86

231480

FX3G-60

MR/ES

60

100–240 V AC

36

24

Relay

40

0.85

175x90x86

231469

FX3G-60

MT/ESS

60

100–240 V AC

36

24

Transistor

(source)*

40

0.85

175x90x86

231473

FX3G-60

MR/DS

60

24 V DC

36

24

Relay

29

0,85

175x90x86

231477

FX3G-60

MT/DSS

60

24 V DC

36

24

Transistor

(source)*

29

0,85

175x90x86

231481

20 MITSUBISHI ELECTRIC

BASE UNITS FX3G SERIES ///

Base Units

Environmental Specifications

Ambient temperature

Protection

Noise durability

Dielectric withstand voltage

Ambient relative humidity

Shock resistance

Vibration resistance

Insulation resistance

Ground

Fuse

Environment

Certifications

¨ FX 1S

¨ FX 1N

þ FX 3G

0–55 °C (storage temperature: -25–+75 °C)

IP10

1000 Vpp with noise generator; 1 µs at 30–100 Hz

1500 V AC, 1 min.

5–95 % (non-condensing)

147m/s 2 Acceleration, Action time: 11ms, 3 times by half-sine pulse in each direction X, Y, and Z

Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting

500 V DC, 5 M

W

Class D: Grounding resistance 100

W or less

For FX3G-14M

첸 and FX3G-24M

: 250 V 1 A; For FX3G-40M

첸 and FX3G-60M

: 250 V 3.15 A

Avoid environments containing corrosive gases, install in a dust-free location.

Please refer to pages 66–67 in this catalogue

¨ FX 3U

¨ FX 3UC

2

Electrical Specifications

Power supply

Inrush current at ON

100–240 V AC (+10 %/-15 %), 50/60 Hz

30 A/<5 ms (at 100 V AC);

50 A/<5 ms (at 200 V AC)

Allowable momentary power failure time

10 ms

Primary power supply —

External power supply (24 V DC) 400 mA

Switching voltage (max.)

Transistor modules

V <240 V AC, <30 V DC 5–30 V DC

Max. output current

- per output

- per group*

A 2

A 8

0.5

0.8

Max. switching current

Response time

- inductive load 80 VA ms 10

12 W

<0.2(<5 µs for Y0,Y1)

Life of contacts (switching times)

� 3,000,000 at 20 VA; 1,000,000 at 35 VA;

200,000 at 80 VA

The 40 and 60 I/O points main units supports 5 µs for Y2.

Not guaranteed by Mitsubishi Electric.

* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and

2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.

Programming Specifications

Program data

I/O points (addresses)

Address range

Program memory

Cycle period

Number of instructions

Programming language

Program execution

Program protection

256 total (combined local and CC-Link remote I/O)

Max. 128 direct addressing and max. 128 remote I/O

32,000 steps EEPROM (internal), exchangeable EEPROM memory cassette

0.21 µs or 0.42 µs/contact instruction

29 sequence instructions,

2 step ladder instructions,

123 applied instructions

Step ladder, instruction list, SFC

Cyclical execution, refresh mode processing

2 different keywords, maximum password length 16 characters

Operands

Internal relays

Special relays

Step ladder

Timer

Ext. preset value via potentiometer

Counter

High-speed counter

Real-time clock

Data register

File register

Index register

Special register

Pointer

Nestings

Interrupt inputs

Constants

7680

512

4096

320

2

235

6 single phase inputs (max. 60 kHz),

3 double phase inputs (max. 30 kHz)

Year, month, day, hour, minute, second, weekday

8.000

24,000 (ER0~R23999) internal/optional memory

16

512 (D8000-D8511)

2,048

8

6

16 bits: K: -32,768 to +32,767; hex: 0–FFFF

32 bits: K: 2,147,483,648 to +2,147,483,647; hex: 0–FFFF FFFF

MITSUBISHI ELECTRIC 21

///

BASE UNITS

FX3U SERIES

2

The MELSEC FX 3U Series

RAM/EEPROM memory for up to

64,000 PLC program steps gives you plenty of reserve, even for big, complex applications.

Add-in function boards can be installed in the PLC to provide a second RS485 /

RS422 / RS232/USB communications interface for programming or network configurations.

An integrated RUN/STOP switch is available.

Connection possibility for special function adapter modules

Integrated serial interface for direct communication with computers

Integrated high-speed counter for processing fast input signals. For example, you can configure six

100 kHz counters and two 10 kHz counters.

Interrupt processing is also handled via the inputs.

The base units can be expanded to provide configurations with up to 384 inputs and outputs with compact extension units

(total of 384 only by using main unit I/Os, extension unit I/Os and remote I/Os).

Integrated real-time clock with year, month, days and time

Three integrated pulse outputs for frequencies up to 100 kHz with deceleration and acceleration ramps for controlling stepping motors and outputting pulse-width modulated signals .

Description of the Unit Components

Battery cover

Battery

Installation place for

FX3U-7DM

Expansion board dummy cover

RUN/STOP switch

Periphal device connecting connector

Top cover with Model name

(used, if FX3U-7DM is not installed)

Protective cover

Terminal block cover

Input terminals

LEDs for indicating the input status

LEDs for indicating the operating status

Extension device connecting connector cover

LEDs for indicating the output status

Output terminals

Terminal block cover

Protective cover

22 MITSUBISHI ELECTRIC

Base Units

Base Units with 16 I/Os

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

8

8

16

24 V DC

Relay

25 W kg 0.6

mm 130x90x86

Art. no. 231498

Base Units with 32 I/Os

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

32

24 V DC

16

16

Relay

30 W kg 0.65

mm 150x90x86

Art. no. 231499

FX3U-16

MR/ES

8

8

16

100–240 V AC

Relay

30 VA

0.6

130x90x86

231486

BASE UNITS

FX3U SERIES

///

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

¨ FX 3UC

Base Units FX 3U

The FX 3U series base units are available with 16, 32, 48, 64, 80 or

128 input/output points expandable to 384 points.

It is possible to choose between relay and transistor output type.

Note: Additional special versions are available on request.

Special Features:

Integrated serial interface for communication between PCs and HMI

Integrated positioning control

Exchangeable interface modules for direct mounting into a base unit

LEDs for indicating the input and output status

Slot for memory cassettes

Integrated real-time clock

Expandable with digital I/O modules, special function modules and ADP modules

User-friendly programming systems, including IEC 1131.3

(EN 61131.3) compatible programming software, HMIs and hand-held programming units

2

FX3U-16

MT/DSS

16

24 V DC

8

8

Transistor

(source type)

25 W

0.6

130x90x86

231503

FX3U-16

MT/ESS

16

100–240 V AC

8

8

Transistor

(source type)

30 VA

0.6

130x90x86

231492

FX3U-32

MR/ES

32

100–240 V AC

16

16

Relay

35 VA

0.65

150x90x86

231487

FX3U-32

MT/DSS

32

24 V DC

16

16

Transistor

(source type)

30 W

0.65

150x90x86

231504

FX3U-32

MT/ESS

32

100–240 V AC

16

16

Transistor

(source type)

35 VA

0.65

150x90x86

231493

MITSUBISHI ELECTRIC 23

///

BASE UNITS

FX3U SERIES

2

Base Units with 48 I/Os

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

48

24 V DC

24

24

Relay

35 W kg 0.85

mm 182x90x86

Art. no. 231500

48

100–240 V AC

24

24

Relay

40 VA

0.85

182x90x86

231488

FX3U-48

MT/ESS

48

100–240 V AC

24

24

Transistor

(source type)

40 VA

0.85

182x90x86

231494

FX3U-48

MT/DSS

48

24 V DC

24

24

Transistor

(source type)

35 W

0.85

182x90x86

231505

Base Units with 64 I/Os

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

64

24 V DC

32

32

Relay

40 W kg 1.0

mm 220x90x86

Art. no. 231501

FX3U-64

MR/ES

64

100–240 V AC

32

32

Relay

45 VA

1.0

220x90x86

231489

FX3U-64

MT/ESS

64

100–240 V AC

32

32

Transistor

(source type)

45 VA

1.0

220x90x86

231495

FX3U-64

MT/DSS

64

24 V DC

32

32

Transistor

(source type)

40 W

1.0

220x90x86

231506

Base Units with 80–128 I/Os

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

Order information

80

24 V DC

40

40

Relay

45 W kg 1.20

mm 285x90x86

Art. no. 231502

FX3U-80

MR/ES

80

100–240 V AC

40

40

Relay

50 VA

1.20

285x90x86

231490

FX3U-80

MT/DSS

80

24 V DC

40

40

Transistor

(source type)

45 W

1.20

285x90x86

231507

FX3U-80

MT/ESS

80

100–240 V AC

40

40

Transistor

(source type)

50 VA

1.20

285x90x86

231496

FX3U-128

MR/ES

128

100–240 V AC

64

64

Relay

65 VA

1.80

350x90x86

231491

FX3U-128

MT/ESS

128

100–240 V AC

64

64

Transistor

(source type)

65 VA

1.80

350x90x86

231497

24 MITSUBISHI ELECTRIC

BASE UNITS

FX3U SERIES

///

Base Units

Environmental Specifications

Ambient temperature

Protection

Noise durability

Dielectric withstand voltage

Ambient relative humidity

Shock resistance

Vibration resistance

Insulation resistance

Ground

Fuse

Environment

Certifications

¨ FX 1S

¨ FX 1N

¨ FX 3G

0–55 °C (storage temperature: -25–+75 °C)

IP10

1000 Vpp with noise generator; 1 µs at 30–100 Hz

AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.

5–95 % (non-condensing)

Acc. to IEC 68-2-27: 15G (3 times each in 3 directions for 11 ms)

Acc. to IEC 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting

500 V DC, 5 M

W

Class D: Grounding resistance 100

W or less

From FX3U-16M

첸 to FX3U-32M

: 3.15 A; From FX3U-48M

첸 to FX3U-128M

: 5 A

Avoid environments containing corrosive gases, install in a dust-free location.

Please refer to pages 66–67 in this catalogue

þ FX 3U

¨ FX 3UC

2

Electrical Specifications

Power supply 24 V DC (+20 %/-30 %)

Inrush current at ON

Allowable momentary power failure time

Primary power supply

5 ms

24 V DC

External power supply (24 V DC) —

100–240 V AC (+10 %/-15 %),

50/60 Hz

30 A/<5 ms (at 100 V AC);

65 A/<5 ms (at 200 V AC)

10 ms

FX3U-16/32MR/ES: 400 mA/

FX3U-48–128MR/ES: 600 mA

Switching voltage (max.)

Max. output current

- per output

- per group*

Type

Transistor modules

V <240 V AC, <30 V DC 5–30 V DC

A 2 0.5 / 0.3

A 8 0.8/1.6

Max. switching current

Response time

- inductive load 80 VA 12 W/7.2 W ms 10 <0.2(Y0,Y1<30 µs)

Life of contacts (switching times)

햴 3,000,000 at 20 VA; 1,000,000 at 35 VA;

200,000 at 80 VA

햲 for Y0 and Y1 = 0.3 A; all others 0.5 A

Not guaranteed by Mitsubishi Electric.

0.8 for 4 per group and 1.6 for 8 per group

* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and

2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.

Programming Specifications

Program data

I/O points (addresses)

Address range

Program memory

Cycle period

Number of instructions

Max. total 384 (with remote I/O)

Max. 256 direct addressing and max. 256 network I/Os

64,000 steps RAM (internal), exchangeable FLROM for easy program exchange

0.065 µs /basic instruction

27 sequence instructions, 2 step ladder instructions,

209 applied instructions

Programming language

Program execution

Program protection

Step ladder, instruction list, SFC

Cyclical execution, refresh mode processing

Password protection with 3 protection levels*

* Protection levels may only be changed with FX-10P/FX-20P/FX-30P.

Operands

Internal relays

Special relays

State relays

Timer

Counter

High-speed counter

High-speed counter speed

Real-time clock

Data register

Extension file register

Index register

Special register

Pointer

Nestings

Interrupt inputs

Constants

7,680

512

4,096

512

235

16

1 phase, 8 points max: 100kHz/6 points

10kHz/2 points

2 phase, 2 points max: 50kHz/2 points

Year, month, day, hour, minute, second, weekday

8,000

32768

16

512

4,096

8

6

16 bits: K: -32768 to +32768, hex: 0–FFFF;

32 bits: K: -2147483648 to +2147483647; hex: 0–FFFF FFFF

MITSUBISHI ELECTRIC 25

2

///

BASE UNITS

FX3UC SERIES

The MELSEC FX 3UC Series

Integrated serial interface for direct communication with computers

Interface adapter connection for

RS232

RS485 / RS422 /

Integrated high-speed counter for processing fast input signals. For example, you can configure six 100 kHz counters and two 10 kHz counters.

Interrupt processing is also handled via the inputs.

Integrated RUN/STOP switch

RAM/EEPROM memory for up to

64,000 PLC program steps gives you plenty of reserve, even for big, complex applications.

The base units can be expanded to provide configurations with up to 384 inputs and outputs with compact extension units

(total of 384 only by using main unit I/Os, extension unit I/Os and remote I/Os).

Three integrated pulse outputs for frequencies up to 100 kHz with deceleration and acceleration ramps for controlling stepping motors and outputting pulse-width modulated signals .

Description of the Unit Components

RUN/STOP switch

LEDs for indicating the operating status

Slot for memory cassettes

Memory cassette

(optional)

Cover for adapter module connection

LEDs for indicating the input status

LEDs for indicating the output status

Protective cover for the extension bus

Extension bus (lateral)

Connection for programming units

26

Back-up battery

Battery cover

Connector for digital outputs

Connector for digital inputs

MITSUBISHI ELECTRIC

BASE UNITS

FX3UC SERIES

///

Base Units

Base Units with 16–96 I/Os

Integrated inputs/outputs

Power supply

Integrated inputs

Integrated outputs

Output type

Power consumption

Weight

Dimensions (WxHxD)

16

24 V DC (+20 %, -15 %)

8

8

Transistor (source type)*

W 6 kg 0.2

mm 34x90x74

Order information Art. no. 231508

* Sink type transistor output units on request.

System Cabling

A choice of terminal blocks with screw or spring terminals are available for easy wiring of the FX3UC modules with standard ribbon cable connectors.

For more details please refer to the

"Accessories" section in this catalogue.

FX3UC-32

MT/DSS

32

24 V DC (+20 %, -15 %)

16

16

Transistor (source type)*

8

0.2

34x90x74

231509

¨ FX 1S

¨ FX 1N

¨ FX 3G

¨ FX 3U

þ FX 3UC

Base Units FX 3UC

The FX 3U series base units are available with 16, 32, 64 or

128 input/output points (expandable to 384 I/Os).

It is possible to choose between relay and transistor output type.

Special Features:

Integrated serial interface for communication between PCs and HMI

Same instruction set as FX3U

Integrated positioning control

Very compact dimensions

LEDs for indicating the input and output status

Slot for memory cassette

Adapter modules and system cabling sets available for units with ribbon cable connectors

Expandable with digital I/O modules, special function modules and ADP modules

User-friendly programming systems, including IEC 1131.3

(EN 61131.3) compatible programming software, HMIs and hand-held programming units

FX3UC-64

MT/DSS

64

24 V DC (+20 %, -15 %)

32

32

Transistor (source type)*

11

0.3

59.7x90x74

231510

96

24 V DC (+20 %, -15 %)

48

48

Transistor (source type)*

14

0.35

85.4x90x74

231511

2

Input terminal block with screw or spring terminals.

.0

.1

.2

.3

.4

.5

.6

.7

Output terminal block with screw or spring terminals. It can be fitted with relay or transistor outputs.

.0

.1

.2

.3

24V+

-

.4

.5

.6

.7

A2A2-

A2A2-

A2A2-

A2A2-

24

V

24

V

24

V

24

V

24

V

24

V

24

V

24

V

MITSUBISHI ELECTRIC 27

///

BASE UNITS

FX3UC SERIES

2

Base Units

Environmental Specifications

Ambient temperature

Protection

Noise durability

Dielectric withstand voltage

Ambient relative humidity

Shock resistance

Vibration resistance

Insulation resistance

Ground

Environment

Certifications

¨ FX 1S

¨ FX 1N

¨ FX 3G

0–55 °C (storage temperature: -25–+75 °C)

IP10

1000 Vpp with noise generator; 1 µs at 30–100 Hz

AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.

5–95 % (non-condensing)

Acc. to IEC 68-2-27: 15G (3 times each in 3 directions for 11 ms)

Acc. to IEC 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting

500 V DC, 5 MW

Class D: Grounding resistance 100 W or less

Avoid environments containing corrosive gases, install in a dust-free location.

Please refer to pages 66–67 in this catalogue

¨ FX 3U

þ FX 3UC

Electrical Specifications

Power supply 24 V DC (+20 %/-30 %)

Inrush current at ON

Allowable momentary power failure time

5 ms

Primary power supply 24 V DC

External power supply (24 V DC) —

28

Switching voltage (max.)

Max. output current

- per output

- per group*

Max. switching current

- inductive load

V 5–30 V DC

A 0.1/0.3

A 0.8/1.6

2.4 W/7.2 W

Response time ms <0.2 (Y0,Y1<30 µs)

Life of contacts (switching times)

햴 햴 3,000,000 at 20 VA; 1,000,000 at 35 VA;

200,000 at 80 VA

햲 for Y0 and Y1 = 0.3 A; all others 0.1 A

Not guaranteed by Mitsubishi Electric.

7.2 W for Y0 to Y3, all other outputs 2.4 W

* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and

2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.

Programming Specifications

Program data

I/O points (addresses)

Address range

Program memory

Cycle period

Number of instructions

Max. total 384 (with remote I/O)

Max. 256 direct addressing and max. 256 network I/Os

64,000 steps RAM (internal), exchangeable FLROM for easy program exchange

0.065 µs/basic instruction

27 sequence instructions, 2 step ladder instructions,

209 applied instructions

Programming language

Program execution

Program protection

Step ladder, instruction list, SFC

Cyclical execution, refresh mode processing

Password protection with 3 protection levels*

* Protection levels may only be changed with FX-30P.

Operands

Internal relays

Special relays

State relays

Timer

Counter

High-speed counter

High-speed counter speed

Real-time clock

Data register

Extension file register

Index register

Special register

Pointer

Nestings

Interrupt inputs

Constants

7,680

512

4,096

512

235

16

1 phase, 8 points max: 100 kHz/6 points

10 kHz/2 points

2 phase, 2 points max: 50 kHz/2 points

Year, month, day, hour, minute, second, weekday

8,000

32768

16

512

4,096

8

6

16 bits: K: -32768 to +32768, hex: 0–FFFF;

32 bits: K: -2147483648 to +2147483647; hex: 0–FFFF FFFF

MITSUBISHI ELECTRIC

Powered Compact Extension Units

COMPACT

EXTENSION

UNITS

///

¨ FX 1S

þ FX 1N

¨ FX 3G

¨ FX 3U

¨ FX 3UC

Extension Units FX 0N

The FX 0N series extension units are available with 40 input/ output points.

It is possible to choose between relay and transistor output type.

Special Features:

LEDs for indicating the input and output status

MELSEC FX 1N series compatible

Integrated service power supply with up to 200 mA capacity

3

FX0N-40

ER-DS

FX0N-40

ET-DSS

Electrical data

Integrated inputs/outputs

AC range (+10 %, -15 %)

Power supply

Frequency at AC

DC range (+20 %, -15 %)

Max. input apparent power

100 V AC

Inrush current at ON

200 V AC

24 V DC

Allowable momentary power failure time

External service power supply (24 V DC)

Inputs

Integrated inputs

Min. current for logical 1

Max. current for logical 0

Response time

Outputs

Integrated outputs

40

100–240 V

Hz 50/60

40 VA

30 A/5 ms

50 A/5 ms

— ms 10 mA 200

24 mA 3.5

40

24 V

20 W

60 A/50 m s

5

24

3.5

mA 1.5

1.5

For all extension units of the MELSEC FX 0N series: 10 ms (at time of shipment)

Output type

Max. switching voltage

Max. output current

- per output

- per group*

Max. switching power

- inductive load

Response time

Life of contacts (switching times)

Mechanical data

Weight

Dimensions (WxHxD)

A 2

A 5

16 16

Relay Relay

Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC

2

5

VA 80 ms 10

40

24 V

30 W

60 A/50 m s

24

3.5

1.5

For all extension units of the MELSEC FX 0N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (only for relay output) kg 0.75

mm 150x90x87

80

10

0.75

150x90x87

5

16

Transistor

0.5

0.8

12

<0.2

0.75

150x90x87

55954 Order information Art. no. 60012 55955

0.8 for 4 per group

Not guaranteed by Mitsubishi Electric.

* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.

MITSUBISHI ELECTRIC 29

3

///

COMPACT

EXTENSION

UNITS

Powered Compact Extension Units ¨ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

Extension Units FX 2N

The FX 2N series extension units are available with 32 or

48 input/output points.

It is possible to choose between relay and transistor output type.

Special Features:

LEDs for indicating the input and output status

MELSEC FX 1N /FX 3G and FX 3U series compatible

Detachable terminal blocks

Integrated service power supply with 250 mA or 460 mA

FX2N-32

ET-ESS/UL

FX2N-48

ER-DS

FX2N-48

ER-ES/UL

FX2N-48

ET-DSS

Electrical data

Integrated inputs/outputs

AC range (+10 %, -15 %)

Power supply frequency at AC

DC range (+20 %, -30 %)

Max. input apparent power

Inrush current at ON

100 V AC

200 V AC

Allowable momentary power failure time

32

100–240 V

Hz 50/60

35 VA

40 A <5 ms

60 A <5 ms ms 10

32

100–240 V

50/60

35 VA

40 A <5 ms

10

48

24 V

30 W

5

48

100–240 V

50/60

45 VA

40 A <5 ms

60 A <5 ms

10

48

24 V

30 W

40 A < 5 ms

60 A < 5 ms

5

External service power supply (24 V DC) mA 250

Power supply int. bus (5 V DC)

Inputs mA 690

Integrated inputs

Min. current for logical 1

Max. current for logical 0

16 mA 3.5

mA 1.5

250

690

16

3.5

1.5

690

24

3.5

1.5

For all extension units of the MELSEC FX 2N series: 10 ms (at time of shipment) Response time

Outputs

Integrated outputs

Output type

Switching voltage (max.)

Max. output current

- per output

- per group *

Max. switching power

- inductive load

Response time

Life of contacts (switching times)

A 2

A 8

16

Relay

16

Transistor

(source)

24

Relay

24

Relay

Generally for relay version: <264 V AC, <30 V DC; for transistor version: 5–30 V DC

0.5

0.8/1.6

2

8

2

8

W 80 ms 10

12

<0.2

80

10

460

690

24

3.5

1.5

80

10

690

24

3.5

1.5

24

Transistor

(source)

0.5

0.8/1.6

12

<0.2

For all extension units of the MELSEC FX 2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)

Mechanical data

Weight

Dimensions (WxHxD) kg 0.65

mm 150x90x87

0.65

150x90x87

0.85

182x90x87

0.85

182x90x87

0.85

182x90x87

Order information Art. no. 65568 65569 66633 65571

Not guaranteed by Mitsubishi Electric

0.8 for 4 per group and 1.6 for 8 per group

* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.

66634

FX2N-48

ET-ESS/UL

24

3.5

1.5

10

460

690

48

100–240 V

50/60

45 VA

40 A <5 ms

60 A <5 ms

24

Transistor

(source)

0.5

0.8/1.6

12

<0.2

0.85

182x90x87

65572

30 MITSUBISHI ELECTRIC

Unpowered Modular Extension Blocks

2

IN

OUT

MODULAR

EXTENSION

UNITS

///

¨ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

Extension Blocks FX 2N

The FX 2N series modular extension blocks are available with

8 or 16 input/output points.

It is possible to choose between relay and transistor output type.

Special Features:

LEDs for indicating the input and output status

MELSEC FX 1N /FX 3G and FX 3U series compatible

Very compact dimensions

Vertically terminal blocks with a cable guide to the upper or lower side

3

FX2N-8EX-ES

FX2N-16EYR-ES/UL

OUT

FX2N-8

EX-ES/UL

FX2N-8

EYR-ES/UL

FX2N-8

EYT-ESS/UL

FX2N-16

EYR-ES/UL

Electrical data

Integrated inputs/outputs

Nbr. of occupied I/O points in the PLC

Power supply

Inputs

Integrated inputs

Min. current for logical 1

Max. current for logical 0

Response time

Outputs

Integrated outputs

Output type

Max. switching voltage

Max. output current

- per output

- per group

Max. switching power

- inductive load

Response time

Life of contacts (switching times)

Mechanical data

Weight

Dimensions (WxHxD)

8

16

4 mA 3.5

mA 1.5

4

Relay

8

8

Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC

A 2

A 8 kg 0.2

mm 43x90x87

8

8

8

3.5

1.5

0.2

43x90x87

8

8

All modular extension blocks are supplied by the base unit.

8

Relay

2

8

0.2

43x90x87

For all extension blocks of the MELSEC FX 2N series: 10 ms (at time of shipment)

8

Transistor

0.5

0.8

0.2

43x90x87

Order information Art. no. 166285 166284 166286 166287

This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.

Not guaranteed by Mitsubishi Electric

16

16

16

3.5

1.5

VA 80 — 80 12 — 80 ms 10 10 10 <0.2

— 10

For all extension units of the MELSEC FX 2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)

0.3

40x90x87

65776

16

16

16

Relay

2

8

0.3

40x90x87

65580

FX2N-16

EYT-ESS/UL

16

16

16

Transistor

(source)

0.5

1.6

12

<0.2

0.3

40x90x87

65581

MITSUBISHI ELECTRIC 31

3

///

MODULAR

EXTENSION

UNITS

Modular Extension Units

POWER

X0

1

X4

5

6

7

2

3

X0

1

X4

5

2

3

6

7

3

X4

1

2

5

6

7

X0

1

2

3

X4

7

X0

5

6

FX -32EX

-DS

FX2NC-32EX-DS

PW

Y0

1

Y0

1

6

7

2

Y4

5

2

3

3

Y4

5

6

7

¨ FX 1S

¨ FX 1N

¨ FX 3G

¨ FX 3U

þ FX 3UC

Extension Units FX 2NC

The modular extension units of the FX 2NC series can be used in combination with FX 3UC series base units only. They are available with 16 or 32 input/output points. For modules with 16 outputs it is possible to choose between relay and transistor output type.

Note: These modules can be used in combination with a FX3UC PLC only!

Special Features:

Very compact dimensions

LEDs for indicating the input and output status

Removable terminal blocks for FX 2NC -16EYR-T-DS and

FX 2NC -16EX-T-DS (interchangeable against optional spring terminal blocks)

앬 Adapter modules and system cabling sets are optionally available for units with ribbon cable connectors (transistor output types)

FX2NC-16EYR-DS

FX2NC-32

EX-DS

FX2NC-32

EYT-DSS

Electrical data

Integrated inputs/outputs

Power supply

Inputs

Integrated inputs

Input current X0

®

X7 / X10

®¥

Min. current for logical 1

X0

®

X7 / X10

®¥

Max. current for logical 0

Isolation

Response time

Outputs

Integrated outputs

Output type

Max. switching voltage

Max. output current

- per output

- per group*

Max. switching power

- inductive load

- lamp load

Response time

Life of contacts (switching times)

Mechanical data

Connection type

Weight

Dimensions (WxHxD)

16

16

7/5 mA 4.5/3.5

16

7/5

4.5/3.5

32

7/5

4.5/3.5

— mA 1.5

— 1.5

— 1.5

Photocoupler isolation between input terminals and PC power for all base units

For all extension units of the MELSEC FX 2NC series: 10 ms (at time of shipment), partly adjustable between 0 and 60 ms in 1 ms steps (REFF, FNC51 = 0–60 ms)

A —

A —

VA —

W — ms —

16

16

Relay

2

4/8

80

100

10 like base unit

16

All modular extension blocks are supplied by the base unit.

16

Transistor

V Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC

Removable screw terminal blocks kg 0.2

mm 20.2x90x89

0.2

24.2x90x89

16

0.1/0.3

0.8

2.4/7.2

0.3/0.9

<0.2

32

32

32

Transistor

0.1/0.3

0.8

2.4/7.2

0.3/0.9

<0.2

Ribbon cable connector Ribbon cable connector Ribbon cable connector Ribbon cable connector

0.15

14.6x90x87

0.2

14.6x90x87

0.2

26.2x90x87

0.2

26.2x90x87

104505 104506 Order information Art. no. 128152 128153 104503 104504

0.3A for Y0 to Y1; 0.1 A all others

7.2 W for Y0 to Y3; 2.4 W all others

0.9 W for Y0 to Y3; 0.3 W all others

* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.

32 MITSUBISHI ELECTRIC

ANALOG

MODULES

///

Analog Output Modules

FX2N-2DA

FX3U-4DA

24 V

D/A

¨ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

FX 2N -2DA, FX 2N

-4DA, FX

3U

-4DA

The analog output modules provide the user with 2 to 4 analog outputs. The modules convert digital values from the FX 1N /FX 3G /FX 3U controller to the analog signals required by the process. The module can output both current and voltage signals.

Note: The FX 3U -4DA can only be used in combination with a FX3G/FX3U series base unit.

Analog channels

Analog output range voltage

Resolution current

Fullscale overall accuracy

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD) inputs outputs

2

0 –+10 V DC/

0–+5 V DC/

4–+20 mA

2.5 mV (12 bits)

4 µA (12 bits)

±1 %

30 mA (from base unit)

85 mA

8 kg 0.3

mm 43x90x87

Order information Art. no. 102868

* Dependent on the ambient temperature

FX2N-4DA

4

-10 –+10 V DC/

0 –+20 mA/

4–+20 mA

5 mV (10 bits)

20 µA (11 bits + sign)

±1 %

30 mA (from base unit)

200 mA

8

0.3

55x90x87

65586

FX3U-4DA

4

-10 –+10 V DC/

0 –+20 mA/

4–+20 mA

0.32 mV (16 bits +sign)

0.63 µA (15 bits)

±0.3–0.5 %*

100 mA (from base unit)

160 mA

8

0.2

55x90x87

169509

4

Analog Input Modules

FX 2N

-2AD

POWER

MITSUBISHI

POWER

24V

¨ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

FX 2N -2AD, FX 2N -4AD, FX 3U -4AD, FX 2N -8AD

The analog input modules provide the user with 2 to 8 analog inputs. The module converts analog process signals into digital values which are further processed by the

MELSEC FX 1N /FX 3G /FX 3U controller.

The actual values or mean values over several measurements may be output.

Note: The FX 3U -4AD can only be used in combination with a FX3G/FX3U series base unit.

Analog channels

Analog input range

Resolution inputs outputs voltage current

Fullscale overall accuracy

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

5 V DC

24 V DC

2

0 –+10 V DC/

0–+5 V DC/

0/ 4–+20 mA

2.5mV, 1.25mV/

4 µA (12 bits)

±1 %

20 mA

(from base unit)

50 mA

(from base unit)

8 kg 0.3

mm 43x90x87

FX2N-4AD

4

-10–+10 V DC/

-20–+20 mA/

4–+20 mA

5 mV

(11 bits + sign)

20 µA

(10 bits + sign)

±1 %

30 mA

(from base unit)

55 mA

8

0.3

55x90x87

FX3U-4AD

4

-10 –+10 V DC/

-20–+20 mA/

4–+20 mA

0.32 mV

(16 bits + sign)

1.25 µA

(15 bits + sign)

±0.3–1 %*

110 mA

(from base unit)

90 mA

8

0.2

55x90x87

FX3UC-4AD

4

-10–+10 V DC/

-20–+20 mA/

8

4–+20 mA

0.32 mV

(16 bits + sign)

1.25 µA

(15 bits + sign)

±0.3–1 %*

100 mA

(from base unit)

80 mA

0.13

20.2x90x79

FX2N-8AD

8

-10 –+10 V DC/

-20–+20 mA/

4–+20 mA

0.63 mV

(14 bits + sign)

2.5 µA

(13 bits + sign)

±0.3–0.5 %*

50 mA

(from base unit)

80 mA

8

0.4

75x105x75

Order information Art. no. 102869 65585 169508 210090 129195

*Dependent on the ambient temperature

Note: The FX 2N -8AD can be configured to accept standard analog inputs as well as selected temperature inputs such as K, T or J type thermocouples.

MITSUBISHI ELECTRIC 33

///

ANALOG

MODULES

4

Combined Analog I/O Modules ¨ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

FX 0N -3A, FX 2N -5A, FX 3U -3A-ADP

The analog input/output modules are available in two different models. They provide the user with 2 or 4 analog inputs and 1 analog output. They serve for conversion of analog process signals into digital values, and vice versa.

As of the FX 2N -5A module the analog inputs can be selected between current or voltage input signals.

Note: The FX 2N -5A may not be used in combination with a FX 1N series base unit.

FX0N-3A

FX2N-5A

24 V

AD / DA

Number of analog points

Input (resolution)

Output (resolution)

Total accuracy

Power supply inputs outputs voltage current voltage current

5 V DC

24 V DC

2

1

0–+10 V (8 bit),

0–+5 V (8 bit)

0/4–+20 mA (8 bit)

Related I/O points

Weight

Dimensions (WxHxD)

Order information Art. no. 41790

*Dependent on the ambient temperature

0–+10 V (8 bit),

0–+5 V (8 bit)

4–+20 mA (8 bit)

±

1 %

30 mA (from base unit)

90 mA (from base unit)

8 kg 0.2

mm 43x90x87

FX2N-5A

4

1

FX3U-3A-ADP

2

1

-10–+10 V (15 bit + sign),

-100–+100 mV (11 bit + sign) 0–+10 V (2.5 mV/12 bit)

-20–+20 mA (14 bit + sign),

0/4–+20 mA (14 bit)

4–+20 mA (5 µA/12 bit)

-10–+10 V (12 bit) 0–+10 V (2.5 mV/12 bit))

0/4–+20 mA (10 bit)

±0.3–1 %*

70 mA (from base unit)

90 mA

8

0.3

55x90x87

4–+20 mA (4 µA/12 bit)

±0.5–1 %*

20 mA (from base unit)

90 mA

0

0.1

17.6x90x89.5

153740 221549

Analog Temperature Input Modules

¨

FX 1S

þ

FX 1N

þ

FX 3G

þ

FX 3U

þ

FX 3UC

FX 2N -4AD-TC, FX 2N -4AD-PT, FX 2N -2LC

The analog input module for thermocouples FX 2N -4AD-TC is used for processing temperatures. It has 4 independent inputs for detecting signals from thermocouples of types J and K. The type of thermocouple can be chosen independently for each point.

The analog input module for Pt100 inputs FX 2N -4AD-PT permits the connection of four

Pt100 sensors to the FX 2N /FX 3U series controller.

The temperature control module FX 2N -2LC is equipped with two temperature input points and two transistor (open collector) output points. It is used to read temperature signals from thermocouples and Pt100 sensors, and performs PID output control

Note: The FX2N-2LC may not be used in combination with a FX1N series base unit.

A / D

Analog inputs

Compensated temperature range

Digital outputs

Resolution

Total accuracy

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

Order information

5 V DC

24 V DC

4 (J or K type)

FX2N-4AD-PT

4 (Pt100 sensors)

-100–+600

-1000–+6000 (J type)/

-1000–+12000 (K type)

-1,000–6,000

(12 bit conversion)

0.3 (J type) / 0.4 (K type) 0.2–0.3 °C

±0.5 % fullscale +1 °C

40 mA (from base unit)

60 mA

8 kg 0.3

mm 55x90x87

Art. no. 65588

±1. 0 % fullscale

30 mA (from base unit)

50 mA

8

0.3

55x90x87

65587

FX2N-2LC

2 points

Thermocouple and

Pt100 sensor

2 transistor output points

0.1 °C or 1 °C

±0.7 % fullscale

(±0.3 % when ambient temperature is 23 °C ±5 °C)

70 mA (from base unit)

55 mA

8

0.3

55x90x87

129196

34 MITSUBISHI ELECTRIC

ANALOG

MODULES

///

Analog Temperature Input Adapters

FX 3U

-4AD-TC-ADP

POWER

FX 3U -4AD-PT-ADP

POWER

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

FX 3U -4AD-TC-ADP, FX 3U -4AD-PT-ADP, FX 3U -4AD-PTW-ADP, FX 3U -4AD-PNK-ADP

The analog input adapter for thermocouples FX 3U -4AD-TC-ADP is used for processing temperatures. It has 4 independent inputs for detecting signals from thermocouples of types J and K.

The FX 3U -4AD-PNK-ADP analog input adapter enables the connection of up to four

Pt1000/Ni1000 thermocouples.

The FX 3U -4AD-PT-ADP and FX 3U -4AD-PTW-ADP analog input adapters enable the connection of up to four Pt100 thermocouples to the PLC system.

All analog adapters can be used in combination with the base units of the

FX 3G /FX 3U /FX 3UC series only.

Note: When connecting the analog adapters to a FX3U base unit, a communications adapter is required.

A direct connection without adapter is possible if these modules are connected to a FX3UC base unit.

When connecting an adapter to a FX3G PLC the communications adapter FX3G-CNV-ADP is required.

FX3U-4AD-TC-ADP

FX3U-4AD-PT-ADP

Analog inputs

Compensated temperature range

Digital outputs

Resolution

Total accuracy

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

5 V DC

24 V DC

4 (J or K type)

-1000–+6000(Jtype)/

FX3U-4AD-PT-ADP FX3U-4AD-PTW-ADP FX3U-4AD-PNK-ADP

4 (Pt100 sensors)

-1000–+10000(Ktype) -500–+2500

4 (Pt100 sensors,

3-wire)

-100–+600

-1000–+6000

(Pt1000/Ni1000 sensors, 2/3 wire)

-50–+250 (Pt1000)/

-40–+110 (Ni1000)

-500–+2500 (Pt1000)/

-400–+1100 (Ni1000)

0.1

0.2–0.3

0.1

±0.5 % fullscale ±0.5–1.0 % fullscale*

15 mA (from base unit) 15 mA (from base unit) 15 mA (from base unit) 15 mA (from base unit)

45 mA 50 mA 50 mA 45 mA

0 kg 0.1

mm 17.6x90 (106)x89.5

Order information Art. no. 165273

*Dependent on the ambient temperature

0

0.1

165272

0

0.1

214173

0

0.1

214172

4

Analog I/O Adapters

FX3U-4AD-ADP

¨

FX 1S

¨

FX 1N

¨

FX 3G

þ

FX 3U

þ

FX 3UC

FX 3U -4AD-ADP, FX 3U -4DA-ADP

The FX 3U -4AD-ADP adapter module for analog input is a special function adapter to add four analog input points to the FX 3G /FX 3U /FX 3UC PLC system.

The FX 3U -4DA-ADP adapter module for analog output is a special function adapter to add four analog output points to the FX 3G /FX 3U /FX 3UC PLC system.

Note: When connecting the analog adapters to a FX3U base unit, a communications adapter is required.

A direct connection without adapter is possible if these modules are connected to a FX3UC base unit.

When connecting an adapter to a FX3G PLC the communications adapter FX3G-CNV-ADP is required.

FX

3U

-4DA-ADP

POWER

FX3U-4DA-ADP

Analog channels inputs outputs

Analog range

Resolution

Overall accuracy

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

5 V DC

24 V DC

4

0–+10 V DC, 4–+20 mA

2.5 mV/10 µA (12 bit/11 bit )

±0.5 %*/±1 %

15 mA (from base unit)

40 mA

0 kg 0.1

mm 17.6x90 (106)x89.5

Order information Art. no. 165241

*Dependent on the ambient temperature and signal quality

4

0–+10 V DC, 4–+20 mA

2.5 mV/4 µA (12 bit)

±0.5 %*/±1 %

15 mA (from base unit)

150 mA

0

0.1

17.6x90 (106)x89.5

165271

MITSUBISHI ELECTRIC 35

///

TEMPERATURE

CONTROL

/DATA

LOGGER

4

Temperature Control Module ¨ FX 1S

¨ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

Temperature control module

The temperature control module FX3U-4LC is equipped with four temperature input points and four transistor (open collector) output points. It is used to read temperature signals from thermocouples and Pt100 sensors, and performs PID output control.

The proportional band, the integral time and the derivative time can be easily set by auto tuning.

The channels are isolated against each other.

24 V

OUT1

OUT2

OUT3

OUT4

Analog inputs

Compensated temperature range

Digital outputs

Resolution

Total accuracy

Power supply

Related I/O points

Dimensions (WxHxD)

5 V DC

24 V DC

Order information

4 (Thermocouple and Pt100 sensors)

°C -200 to +2300

4 NPN transistor open collector output points

°C 0.1 or 1

±0.3 to 0.7 % (fullscale, dependent on the ambient temperature)

160 mA (from base unit)

50 mA

8 mm 90x90x86

Art. no. 232806

Data Logger Module

FX

3U

-CF-ADP

POWER

BUFFER

ERR.

CF CARD

ACCESS

ON

FULL

ACCESS

SLOT

OFF

¨

FX 1S

¨

FX 1N

¨

FX 3G

þ

FX 3U

þ

FX 3UC

Data logger module

The FX3U-CF-ADP is a general purpose data logging adapter. The difference to other available logging units is that the PLC main unit controls the data logging based on user requirements, e.g. periodical or even based. For tracing a timestamp is automatically added to all data storages, that eases alarm and other time critical logging. Another usage is the storage of bigger recipe data. A CompactFlash 쏐 memory card up to 2GB can be used. Six applied instructions allow all kinds of data writing, manipulation or reading, making this adapter the optimum solution towards customer requirements.

Data access method

Connectable units

Time stamp function

Recommended storage media

Max. file size

File format

Max. numbers of files

FIFO function

Power supply 24 V DC

Related I/O points

Dimensions (WxHxD)

Controlled by the main unit, no polling from the logging unit possible.

A maximum of one FX3U-CF-ADP can be connected per PLC.

The real time clock data of the base unit is used.

CompactFlash

쏐 memory card (GT05-MEM-256MC, -512MC,-1GC, -2GC)

512 MB

CSV

63 (Plus one FIFO file.)

One pattern (The file name gets automatically generated.)

130 mA

0 mm 45x90x89.5

Order information Art. no. 230104

36 MITSUBISHI ELECTRIC

HIGH

SPEED

COUNTER

///

High-Speed Counter Modules ¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

FX 2N -1HC, FX 2NC -1HC

In addition to the internal high-speed MELSEC FX counters, the high-speed counter modules FX 2N -1HC and FX 2N c-1HC provide the user with an external counter. It counts 1- or

2-phase pulses up to a frequency of 50 kHz. The counting range covers either 16 or 32 bit.

The two integrated transistor outputs can be switched independently of one another by means of internal comparison functions. Hence, simple positioning tasks can also be realized economically. In addition, the FX 2N -1HC and FX 2Nc -1HC can be used as a ring counter.

Signal level

Counter inputs

Max. counting frequency

Input format

Type of counter

Counting range

Output type

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

5 V DC

24 V DC

5, 12, 24 V DC/7 mA

2 (1 phase) or 1 (2 phase) kHz 50 bit 16, 32

Up/down counter, ring counter

16 bit 0–65535

32 bit -2147483648–+2147483647

2 x transistor (5–24 V DC; 0.5 A)

90 mA (from base unit)

8 kg 0.3

mm 55x90x87

Order information Art. no. 65584

5, 12, 24 V DC/7 mA

2 (1 phase) or 1 (2 phase)

50

16, 32

Up/down counter, ring counter

0–65535

-2147483648–+2147483647

2 x transistor (5–24 V DC; 0.5 A)

90 mA (from base unit)

8

0.13

20.2x90x89

217916

4

High-Speed Counter Adapters

FX

3U

-2HSX-ADP

POWER

X0/3 X2/5

X1/4 X6/7

¨

FX 1S

¨

FX 1N

¨

FX 3G

þ

FX 3U

þ

FX 3UC

FX 3U -4HSX-ADP, FX 3U -2HSY-ADP, FX 3U -2HC

These adapter modules allow direct processing of positioning application data.

The FX 3U -4HSX-ADP and the FX 3U -2HC provide high speed counter inputs up to 200 kHz while the FX 3U -2HSY-ADP delivers 2 channels of pulse train outputs up to 200 kHz.

Note: The adapters FX3U-

-ADP can only be used with the FX3U and they require a function extension board.

FX3U-4HSX-ADP

FX

3U

-2HSY-ADP

POWER

Y0/2 Y1/3

Y4/6 Y5/7

FP.RP

PLS DIR

FX3U-2HSY-ADP

Counter

Max. counting frequency

Input format

Output format

Maximum cable length

Input potential

Output load

Maximum connectivity

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information inputs 4 outputs inputs kHz

1 ch 1 input or

1 ch 2 inputs: 200

2 ch 2 inputs: 100 outputs kHz —

Differential line receiver

(AM26C32 is suitable)

Photocoupler isolation on inputs

— m 10

5 V DC

2

30 mA (from base unit)

30 mA (from base unit)

0 kg 0.08

mm 17.6x90 (106)x89.5

Art. no. 165274

FX3U-2HSY-ADP

2

200

Differential line driver

(AM26C31 is suitable)

Normal rotation pulse train, reverse pulse train or pulse train + one

10

— less than 25 mA

2

30 mA (from base unit)

60 mA (from base unit)

0

0.08

17.6x90 (106)x89.5

165275

FX3U-2HC

2

1 phase input: 200

2 phase input: 200/100/50

Differential line receiver

(AM26C32 is suitable)

Photocoupler isolation on inputs

Transistor output, 5–24 V DC

When the counter value coincides with an output compare value, the appropriate output is set ON.

10

5/12/24 V DC

0.5 A

8

245 mA (from base unit)

8

0.08

55x90x87

232805

MITSUBISHI ELECTRIC 37

///

POSITIONING

MODULES

4

Positioning Modules

FX 2N

-10PG

START

DOG

X0

X1

øA

øB

POWER

ERROR

PGO

FP

RP

CLR

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

FX 2N -1PG-E, FX 2N -10PG

The positioning modules FX 2N -1PG-E and FX 2N -10PG are extremely efficient single-axis positioning modules for controlling either step drives or servo drives (by external regulator) with a pulse chain. They are very suitable for achieving accurate positioning in combination with the MELSEC FX series. The configuration and allocation of the position data are carried out directly via the PLC program. A very wide range of manual and automatic functions are available to the user.

Accessible axes

Output frequency

Signal level for digital inputs

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information

1 pulse/s 10–100 000

24 V DC/40 mA

55 mA (from base unit)

8 kg 0.3

mm 43x90x87

Art. no. 65583

FX2N-10PG

1

1–1 000 000

5 V DC/100 mA; 24 V DC/70 mA

120 mA (from base unit)

8

0.2

43x90x87

140113

Positioning Module for SSCNET

INT 0

INT 1

A

B

START

DOG

INT 0

INT 1

A

B

X READY

Y READY

X ERROR

Y ERROR

POWER

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

SSCNET III Module FX 3U -20SSC-H

The SSCNET module FX 3U -20SSC-H can be used in combination with a FX 3U programmable controller to achieve a cost effective solution for high precision, high speed positioning. The plug-and-play fiber optic SSCNET cabling reduces setup time and increases control distance for positioning operations in a wide range of applications.

Servo parameters and positioning information for the FX 3U -20SSC-H are easily set up with an FX 3U base unit and a personal computer. For parameter setting, monitoring and testing the easy programming software FX Configurator-FP is available.

Note: the FX 3U -20SSC-H can be used in combination with a FX3U- or FX3UC base unit only. Please refer to the Mitsubishi Electric MELSERVO catalog for suitable servo motors and amplifiers.

FX2 CU -20SSC-H

Accessible axes

Output frequency

Pulse output format

Communications speed

Starting time

Max. to PLC connectable modules

Status displays

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information

2 (independent or interpolation)

1 Hz to 50 MHz

SSCNET III (servo bus)

50 Mbps ms 1.6 (+1.7 SSCNET cycle time)

Up to 8 can be connected to the FX3U PLC

Power, module status, axis status, error

100 mA

8 kg 0.3

mm 55x90x87

Art. no. 168914

38 MITSUBISHI ELECTRIC

NETWORK

MODULES

///

Network Modules for CC-Link

RUN

ERR.

MST

TEST 1

TEST 2

L RUN

L ERR.

SW

M/S

PRM

TIME

LINE

SD

RD

CCLINK

¨ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

CC-Link Master Module FX 2N -16CCL-M

The CC-Link network enables the controlling and monitoring of decentralized I/O modules at the machine.

The CC-Link master module FX2N-16CCL-M is a special extension block which assigns an

FX series PLC as the master station of the CC-Link system.

The setting of all modules within the network is handled directly via the master module.

Up to 15 remote stations and remote device stations can be connected to the master station as decentralized I/O stations. These remote stations can be up to 7 I/O modules and up to 8 remote device stations. 2 master modules can be connected to one FX

1N

, FX 3G or

FX 3U /FX3 UC base unit.

The maximum communications distance is 1200 m without repeater.

Note: When connecting this module to a FX3UC base unit, the communications adapter FX2N-CNV-IF resp. a power supply unit FX3UC-1PS-5V is required. For more informations about CC-Link please refer to the "Automation Book".

Module type

Link points per station

Max. number of I/O points

Number of connectable modules

5 V DC

Power supply

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Master station

I/O points 32 register 8

128 (with FX1N PLC), 256 (with FX3G PLC)*, 384 (with FX3U PLC)*

Max. 15

150 mA

8

0.4

85x90x87

Order information

*Including I/O points in PLC and network.

Art. no. 133596

4

RUN

ERR.

L RUN

L ERR.

SD

RD

POWER

FX

3U

-64CCL

FX3U-64CCL Interface Block

The FX3U-64CCL CC-Link interface block is available for FX3 series main units and enables

CC-Link V2 functionality, for example expanded cyclic transmission which facilitates handling of multiple data processes.

Note: When attaching the FX3U-64CCL to an FX3UC main unit, the FX2NC-CNV-IF interface converter or the FX3UC-1PS-5V power supply unit is required. For more informations about CC-Link please refer to the

"Automation Book".

Module type

Link points per station

Max. transmission speed

Related I/O points

Power supply

Weight

Dimensions (WxHxD)

Order information

Intelligent device station

I/O points 128 (Occupying 1 station with Octuple expanded cyclic setting) register 32 (Occupying 1 station with Octuple expanded cyclic setting)

10 Mbps

8

24 V DC/220 mA

0.3

55x90x87

Art. no. 217915

MITSUBISHI ELECTRIC 39

///

NETWORK

MODULES

4

Network Modules for CC-Link ¨ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

CC-Link Communication Module FX 2N -32CCL

The communication module FX 2N -32CCL enables the user to connect to the CC-Link network with a superior PLC system as master CPU. This gives him access to the network of all MELSEC PLC systems and frequency inverters and to additional products from other suppliers.

Thus the network is expandable via the digital inputs/outputs of the FX modules to a maximum of 256 I/Os.

The buffer memory of the FX

2N

-32CCL is read and written by FROM/TO instructions.

The connection is to the extension bus on the right side of the controller.

Note: For more informations about CC-Link please refer to the "Automation Book".

LRUN • LERR • RD • SD

Module type

Link points per station

Max. number of I/O points

Number of connectable modules

5 V DC

Power supply

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information

Remote station

I/O points 32 register 8

— max. 130 mA (from base unit)

50 mA

8

0.3

43x90x87

Art. no. 102961

Network Module for AS-Interface

¨

FX 1S

þ

FX 1N

þ

FX 3G

þ

FX 3U

þ

FX 3UC

AS-Interface Module FX 2N -32ASI-M

The FX 2N -32ASI-M serves as master module for the connection of the FX 1N , FX 3G , FX 3U and FX 3UC PLC to the AS-Interface system. Up to 31 slave units with up to 4 inputs and

4 outputs can be controlled.

U ASI

ASI ACTIVE

ADRESS/ERROR

POWER

PRJ MODE

PRG ENABLE

FROM/TO

CONFIG ERR

Module type

Max. number of I/O points

Communication protocol

Communication speed

Method

Communication cable

Total extension distance

Max. number of controllable units

I/O refresh time

Network setup

Display

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

5 V DC

24 V DC

FX2N-32ASI-M

Master module

128 (with FX1N PLC); 256 (with FX3G PLC); 384 (with FX3U/FX3UC PLC)*

AS-Interface standard kbps 167

APM method (Alternating Pulse Modulation)

AS-Interface standard cable

Up to 31 slave modules (up to 4 inputs / 4 outputs per slave)

Max. 5 ms

2 key network setup

7-segment display for status and diagnosis messages

150 mA (from base unit)

70 mA external

8 kg 0.2

mm 55x90x87

Order information

*Including I/O points in PLC and network.

Art. no. 103314

40 MITSUBISHI ELECTRIC

NETWORK

MODULES

///

Network Module for Ethernet

POWER

LINK

ACT

SD

RD

þ FX 1S

þ FX 1N

¨ FX 3G

¨ FX 3U

¨ FX 3UC

Ethernet Communications Adapter FX 2NC -ENET-ADP

The FX 2NC -ENET-ADP communications adapter is an Ethernet interface with 10BASE-T specifications for the FX 1S and FX 1N series.

The FX 2NC -ENET-ADP enables upload, download, monitor and test sequence of programs via Ethernet from a personal computer (GX Developer or MX Component and the virtual

COM port driver installed).

Note: When connecting this adapter module to a FX1S or FX1N PLC the communications adapter

FX1N-CNV-BD is required.

Protocol

No. of simultaneous open connections

Interface

Connector

Max. transfer rate

Cable

Related I/O points

Power supply

5 V DC

24 V DC

Weight

Dimensions (WxHxD)

Order information

TCP/IP

1

IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT)

RJ45 (to Ethernet), 3 screw terminals (to ground)

10 Mbit/s

CAT5 STP or 3 STP

0

135 mA (from base unit)

— kg 0.1

mm 19.1x90x78

Art. no. 157447

4

Network Module for Ethernet

RUN

INIT.

100M

SD

RD

ERR.

COM.ERR.

POWER

¨ FX 1S

¨ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

Ethernet Communications Module FX 3U -ENET

The FX3U-ENET communications module provides the FX 3G , FX 3U or FX3 UC with a direct connection on to an Ethernet network.

With the FX3U-ENET installed an FX 3G /FX 3U /FX3 UC PLC can exchange data quickly and easily with process visualization systems in addition to supporting full program

UP/DOWN load as well as comprehensive monitoring support. The module also supports

Peer to Peer connection and MC Protocol. It is easily set-up with the FX Configurator-EN software.

Note: The FX 3U -ENET can be used in combination with a FX3G, FX3U- or FX3UC base unit only.

FX3U-ENET

10BASE-T/100BASE-TX

C1

C2

C3

C4

C5

C6

C7

C8

Protocol

Communication mode

No. of simultaneous open connections

Fixed buffer communication

Communication with mail server

Interface

Connector

Max. transfer rate

Max. segment length

Cable

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information

TCP/IP, UDP

Full-duplex / half-duplex

8

1023 word x 8

SMTP, POP3

IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT)

RJ45

100 Mbits/s, 10 Mbit/s m 100

CAT5 STP or 3 STP

240 mA (from base unit)

8 kg 0.3

mm 55x90x87

Art. no. 166086

MITSUBISHI ELECTRIC 41

///

NETWORK

MODULES

4

Network Module for Profibus/DP

RUN

TOKEN

FROM/TO

ERROR

POWER

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

Master module FX 3U -64DP-M

The FX 3U -64DP-M PROFIBUS/DP master module enables you to integrate a MELSEC FX 3U or FX3 UC PLC system as a class 1 master of a PROFIBUS/DP network.

This interface module provides your FX 3U /FX 3UC base unit with an intelligent Profibus/DP link for the implementation of decentralised control tasks.

The FX 3U Profibus/DP master provides comprehensive data and alarm processing to the

Profibus/DP V1 standard. It is easily set up with the GX Configurator-DP software.

Note: The FX 3U -64DP-M can be used in combination with a FX3U- or FX3UC base unit only.

Module type

Transmission type

Transmission data

Interface

Max. number of master per configuration

Repeaters

Max. number of slaves

Communications speed

Communications distance

Communication cable

5 V DC

Power supply

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information

Accessories

Master

Bus network

32 byte/slave (normal service mode)

244 byte/slave (extended service mode)

PROFIBUS/DP (with 9 pole D-SUB connector)

1

3

64

PROFIBUS standard m Max. 1,200 (depends on communication speed)

PROFIBUS cable with 9-pin D-SUB connector

Max. 155 mA (from base unit)

8 kg 0.2

mm 43x90x87

Art. no. 166085

PROFIBUS connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or

PROFICON-PLUS-PG, art. no. 140009

Network Module for Profibus/DP

¨

FX 1S

þ

FX 1N

¨

FX 3G

¨

FX 3U

¨

FX 3UC

Slave Module FX 0N -32NT-DP

The FX 0N -32NT-DP PROFIBUS/DP slave module enables you to integrate a MELSEC FX 1N in an existing PROFIBUS/DP network.

This interface module provides your FX 1N CPU with an intelligent PROFIBUS/DP link for the implementation of decentralised control tasks.

It links the system to the master PLC in the PROFIBUS/DP network for efficient and trouble-free data exchange.

POWER

DC RUN

BF DIA

Module type

Interface

Communications speed

Profibus specifications

Communications distance

Communication cable

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information

Accessories

Slave

PROFIBUS/DP (with 9 pole D-SUB connector)

PROFIBUS standard

PROFIBUS standard m Max. 1,200 (depends on communication speed)

PROFIBUS cable with 9-pin D-SUB connector

Max. 170 mA (from base unit)

60 mA

8 kg 0.3

mm 43x90x87

Art. no. 62125

PROFIBUS connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or

PROFICON-PLUS-PG, art. no. 140009

42 MITSUBISHI ELECTRIC

NETWORK

MODULES

///

Network Module for Profibus/DP ¨ FX 1S

¨ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

FX 3U -32DP PROFIBUS DP Slave Module

The FX 3U -32DP PROFIBUS DP slave module is available for FX3 series main units and allows the attached FX main unit to function as a slave station on a PROFIBUS DP-V1 network. PROFIBUS DP-V1 functionality supports extensive alarm processing and messaging on top of standard cyclic data exchange.

Note: When attaching the FX3U-32DP to an FX3UC main unit, the FX2NC-CNV-IF interface converter or the FX3UC-1PS-5V power supply unit is required.

RUN

TOKEN

FROM/TO

DIA

POWER

Module type

Transmission type

Transmission data

Slave station

Bus network

Max. 144 bytes

Interface PROFIBUS DP connector

Max. number of slave stations per configuration 8

Communication speed

Communication distance

Communication cable

Max. 12 Mbps

Max. 1,200m (depends on communication speed)

PROFIBUS cable with PROFIBUS DP connector

Related I/O points

Power supply

Weight

Dimensions (WxHxD)

8

Internal 24 V DC/145 mA kg 0.2

mm 43x90x89

Order information Art. no. 194214

4

Remote I/O Station for PROFIBUS/DP

L N

COM 24 +

RUN

STOP

MITSUBISHI

POWER

RUN

BF

DIA

Remote I/O Station FX 2N -32DP-IF

The remote I/O station FX 2N -32DP-IF forms an extremely compact communication unit and provides a connection of I/O modules with up to 256 I/O points and/or up to 8 special function modules as an alternative.

It features an entire electrical isolation of the PROFIBUS/DP connector and of the sensor/actuator circuits.

The FX 2N -32DP-IF includes a 240 V power supply unit and a 24 V service voltage terminal, e.g. for analog modules. The FX 2N -32DP-IF-D is supplied with 24 V DC.

PROFIBUS data such as the baud rate or I/O data can be monitored directly with the programming software or on the hand-held programming units FX-10P/FX-20P/ FX-30P. This facilitates an easy error diagnosis directly on the remote I/O station.

ON

OFF

Power supply

Power consumption

Internal current consumption

Interface (connectors)

Communication speed

200 m

100 m

Communication distance

Communication cable

Max. number of controllable I/O points

Related I/O points

Weight

Dimensions (WxHxD) distance

1200 m

1000 m

400 m

Order information

100–240 V AC

(+10 %/-15 %) 50/60 Hz

30 VA

5 V DC/max. 220 mA (from base unit),

24 V DC/500 mA

FX2N-32DP-IF-D

24 V DC

(+20 %/-30 %)

14 W

5 V DC/max. 220 mA (from base unit)

9-pin D-SUB for PROFIBUS/DP,

8-pin Mini-DIN for PC or programming unit FX-10P/FX-20P/FX-30P kbps 9.6/19.2/45.45/93.75

kbps 187.5

kbps 500 kbps 1500 kbps 3000/6000/12000 m Max. 1200 (depends on communication speed)

PROFIBUS cable with 9-pin D-SUB connector

256

0 kg 0.4

mm 75x98x87

Art. no. 145401 142763

MITSUBISHI ELECTRIC 43

///

NETWORK

MODULES

4

Network Module for DeviceNet

POWER

¨ FX 1S

¨ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

DeviceNet Slave Module FX 2N -64DNET

The DeviceNet slave module FX 2N -64DNET can be used to connect FX 3G and FX 3U programmable controllers to a DeviceNet network.

The FX 2N -64DNET can communicate to the master by the master/slave communication

(using the master/slave I/O connection), and to other nodes supporting the UCMM connection by client/server communication (using the UCMM connection).

The communication between the programmable controller and the internal buffer memory of the FX

2N-

64DNET is handled by FROM/ TO instructions.

/TO

MS

NS

Module type

Node type

Station numbers

Supported communication speeds

Communication data

(open connection)

Master/ slave

UCMM client/server

Communication data

(I/O connection)

Module ID code

Status displays

Related I/O points

Power supply

Weight

Dimensions (WxHxD) no. of connections

Slave (group 2)

G2 Server

0–63 points kbps 125/250/500

1 connection (group 2) transfer time-out no. of connections data length type data length

2,000 ms (ACK time-out)

63/63 (group 1, 3)

Max. 64 bytes per connection

Polling, cyclic, change of state

Max. 64 bytes (fragmentation is possible)

K 7090

5 V DC

24 V DC

Power, module status, network status

8

120 mA mA 50 mA kg 0.2

mm 43x90x87

Order information Art. no. 131708

Network Module for CANopen

RUN

FROM/TO

Tx/Rx

ERROR

POWER

¨

FX 1S

þ

FX 1N

þ

FX 3G

þ

FX 3U

þ

FX 3UC

CANopen Master-Modul FX

2N

-32CAN

The FX

2N

-32CAN communications module makes it possible to connect an FX

1N

, FX

3G or

FX 3U /FX3 UC PLC to an existing CANopen network.

In addition to real-time capabilities and high-speed data transfer at rates of up to 1Mbit/s the

CANopen module also shines with high transfer reliability and simple network configuration.

Up to 120 data words can be sent and received as process data objects (30 PDOs). The number of words that can be transmitted in each direction can be set between 1 and 120.

Communication with the module’s memory buffer is performed with simple FROM/TO instructions.

44

Module type

Power supply

CAN standard

CANopen standard by CiA

Additional CANopen features

NMT, Guarding, and Guarding request based on DS-302 V2.0.

network variables based on DS-405 V1.0

Max. nbr. of modules that can be connected to the network

Station numbers

Supported baud rate

Status displays

30 without repeater; 127 with repeater

1–127 kBaud 10, 20, 50, 125, 250, 500, 800, 1000

RUN, Error, Power, Network status

Related I/O points

Power supply

Weight

Dimensions (WxHxD)

5 V DC

24 V DC

CANopen master

5 V DC (via base unit)

ISO 11898/1993

DS-301 version 3.0

8

290 mA

— kg 0.2

mm 43x90x88.7

Order information Art. no. 141179

MITSUBISHI ELECTRIC

COMMUNICATIONS

MODULES

///

Modbus & Serial Communication Special Adapters þ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

Active data modules (RS485)

The addition of active data interface modules permit active communication between the

PLC and surrounding devices. With RS485 communication can be configured as either

1:N multidrop, parallel link or peer to peer operation.

FX3U-485ADP-MB also supports Modbus RTU and Modbus ASCII.

FX2NC-485ADP

FX

3U

-

MB

POWER

RD

SD

330

OPEN

110

FX3U-485ADP

Interface

Communication speed*

Max. communication distance

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

RS485 kbps 0.3–19.2

m 500

Max. 150 mA (from base unit)

0 kg 0.1

mm 19.1x90x78

FX3U-485ADP-MB

RS485; Modbus RS485

0.3–19.2

500

20 mA (from base unit)

0

0.08

17.6x90(106)x74

Order information Art. no. 149111 206191

Application for FX1S/FX1N base unit

Application for FX3G/FX3U/FX3UC base units

* Speed depends on communication method (Parallel link, N:N Network, No protocol, Dedicated protocol etc.)

Note: When connecting these adapter modules to a FX3U, a communications adapter FX3U첸첸첸 -BD is required. When connecting the

FX2NC adapters to a FX1S or FX1N PLC the communications adapter FX1N-CNV-BD is required. When connecting an FX3U adapter to a FX3G

PLC the communications adapter FX3G-CNV-ADP is required.

4

Interface Modules

POWER

RD

SD

FX2NC-232ADP

FX

3U

-232ADP

POWER

RD

SD

FX3U-232ADP

þ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

Active Data Interface Modules FX 2NC -232ADP, FX 3U -232ADP

The additional active data interface modules permit active communication between the

PLC and surrounding RS232C peripherals. All device information can be sent or received via these interfaces.

The module is suitable for the connection of printers, bar code readers, PCs and other PLC systems. The communication is handled by the PLC program using the RS instruction.

The connection is to the communications bus on the left side of the controller.

The internal serial RS422 interface is also fully available.

Note: The FX 2NC -232ADP requires a FX 2N -CNV-BD interface adapter when connecting to a FX1S or FX1N base unit.

The FX3U-232ADP can be used in combination with a FX3G, FX3U or FX3UC base unit only. When connecting the interface modules to a FX3U base unit, an interface or communications adapter FX3U-

쏔쏔쏔

-B is required.

A direct connection without adapter is possible if these modules are connected to a FX3UC base unit.

Interface

Communication speed*

Communication distance

Communication cable

Communication mode

Protocols

Format

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

5 V DC

24 V DC

FX3U-232ADP

RS232C with 9 pin D-SUB compact plug (photocoupler isolation) kbps 0.3–19.2

0.3–115.2

m Max. 15

Shielded cable

Max. 15

Shielded cable

Half duplex /Full Duplex Half duplex /Full Duplex

Computer link (dedicated protocol: format1, format4), no protocol, optional programming port

7 or 8 bits, parity: none/even/odd, stop bits: 1 or 2

100 mA (from base unit)

0 kg 0.1

mm 19.1x90x83

7 or 8 bits, parity: none/even/odd, stop bits: 1 or 2

30 mA (from base unit)

0

0.08

17.6x90(106)x81.5

Order information Art. no. 149110 165276

* Speed depends on communication method (No protocol, Dedicated protocol, Protocol for programming tool)

MITSUBISHI ELECTRIC 45

///

COMMUNICATIONS

MODULES/

EXTENSION

ADAPTERS

4

Interface Modules ¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

Interface Module FX 2N -232IF

The interface module FX 2N -232IF provides an RS232C interface for serial data communications with the MELSEC FX 3U and FX 3UC .

Communication with PCs, printers, modems, barcode readers etc. is handled by the PLC program.

The send and receive data are stored in the FX 2N -232IF’s own buffer memory.

Changes at the user program are not possible via this interface module.

Interface

Communication speed

Communication distance

Communication cable

Communication mode

Protocols

Send and receive buffer

Format

Power supply

5 V DC

24 V DC

Related I/O points

Weight

Dimensions (WxHxD)

Order information

RS232C with 9 pole D-SUB connector (photocoupler isolation) kbps 0.3–19.2

m Max. 15

Shielded cable

Full duplex

Non protocol mode/start stop synchronisation

512 byte each

7 or 8 bits, parity none/even/odd, stop bits: 1 or 2

40 mA (from base unit)

80 mA

8 kg 0.3

mm 55x90x87

Art. no. 66640

Digital Extension Adapter Boards

FX1N-2EYT-BD

þ FX 1S

þ FX 1N

¨ FX 3G

¨ FX 3U

¨ FX 3UC

Extension Adapters FX 1N -4EX-BD, FX 1N -2EYT-BD

The extension adapters for the FX 1N series are available with 4 inputs or 2 outputs.

They are installed directly in the controller of the FX 1S or FX 1N series and therefore do not require any additional installation space.

These adapters are especially advantageous when only few additional I/Os are required and there is not enough room for an adjacent module to be installed.

FX1N-2EYT-BD

Connector side

Applicable for

Integrated inputs/outputs

Power supply

Integrated inputs

Input level voltage current

Integrated outputs

Output type

Max. switching voltage

Weight

Dimensions (WxHxD)

Order information

Base units FX1S/FX1N

4

From base unit

4

24 V DC (+20 %/-15 %)

5 mA (24 V DC)

V — kg 0.02

mm 43x38.5x22

Art. no. 139418

FX1N-2EYT-BD

Base units FX1S/FX1N

2

From base unit

2

Transistor

5–30 V DC

0.02

43x38.5x22

139420

46 MITSUBISHI ELECTRIC

EXTENSION

ADAPTERS

///

Analog Adapter Boards

FX1N-2AD

FX1N-2AD-BD

þ FX 1S

þ FX 1N

þ FX 3G

¨ FX 3U

¨ FX 3UC

Analog Adapter Boards FX 1N -2AD-BD, FX 1N -1DA-BD, FX 3G -1DA-BD and

FX 3G -2AD-BD

The analog input adapter boards FX 1N -2AD-BD and FX 3G -2AD-BD provide the user with

2 analog inputs.

The boards convert analog process signals into digital values which are further processed by the MELSEC controller.

The analog adapters FX 1N -1DA-BD and FX 3G -1DA-BD provide the user with 1 analog output. The modules convert digital values from the FX 1S /FX 1N /FX 3G controller to the analog signals required by the process.

Connector side

FX1N-1DA-BD

FX1N-1DA-BD

Connector side

Applicable for

Power supply

Analog channels inputs outputs

Analog input range

Input resistance

External load voltage input current input voltage output current output

Resolution

Overall accuracy

Conversion speed

Related I/O points

Weight

Dimensions (WxHxD) analog

® digital digital

® analog

Order information

Base units FX1S/FX1N

From base unit

2

0 –+10 V DC/4–+20 mA k

W

300

W

250 k

W

W

2.5 mV (12 bits)/8 µA (11 bits)

±1 %

1 program cycle ms —

0 kg 0.02

mm 43x38.5x22

Art. no. 139421

Base units FX1S/FX1N

From base unit

1

0 –+10 V DC/4–+20 mA

2 –1,000

< 500

2.5 mV (12 bits)/8 µA (11 bits)

±1 %

1 program cycle

0

0.02

43x38.5x22

139422

4

FX3G-2AD-BD

FX3G-1DA-BD

Applicable for

Power supply

Analog channels inputs outputs

Analog input range

Input resistance

External load voltage input current input voltage output current output

Resolution

Overall accuracy

Conversion speed

Related I/O points

Weight

Dimensions (WxHxD) analog

® digital digital

® analog

Order information

Base units FX3G

From base unit

2

0 –+10 V DC/4–+20 mA k

W

198.7

W

250 k

W

W

2.5 mV (12 bits)/8 µA (11 bits)

±1 %

180 µs (1 program cycle) ms —

0 kg 0.02

mm 35x51.2x29.2

Art. no. 221265

Base units FX3G

From base unit

1

0 –+10 V DC/4–+20 mA

2 –1,000

< 500

2.5 mV (12 bits)/8 µA (11 bits)

±1 %

60 µs (1 program cycle)

0

0.02

35x51.2x29.2

221266

MITSUBISHI ELECTRIC 47

///

ADAPTER

BOARDS

4

Setpoint Adapter Boards

FX1N-8AV-BD

FX3G-8AV-BD

FX1N-8AV-BD

þ FX 1S

þ FX 1N

þ FX 3G

¨ FX 3U

¨ FX 3UC

Analog Setpoint Adapters FX 1N -8AV-BD and FX 3G -8AV-BD

The FX

첸첸

-8AV-BD analog setpoint adapters enable the user to set 8 analog setpoint values. The analog values of the potentiometers are read into the controller and used as default setpoint values for timers, counters and data registers by the user’s PLC programs.

Setpoint value polling and the definition of the potentiometer scales are performed in the PLC program using the dedicated instructions VRRD/VRSC (FNC85/86).

The FX

첸첸

-8AV-BD analog setpoint adapters are installed in the expansion slot of the

FX

1S

/FX 1N / FX 3G CPU. No additional power supply is required for operation.

Applicable for

Power supply

Adjusting range

Related I/O points

Potentiometer evaluation

Weight

Dimensions (WxHxD)

Order information

Base units FX1S/FX1N

From base unit

8 bit

0

FX3G-8AV-BD

Base units FX3G

From base unit

8 bit

0

Via application instruction from the PLC CPU (FNC 85/86) kg 0.02

0.02

mm 43x38.5x22

35x51.2x12

Art. no. 130744 221267

Communications Adapter Boards

RD

SD

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

¨ FX 3UC

Adapter Board FX 3U -USB-BD

This adapter board allows direct USB 2.0 connection to the front of the FX 3U PLC for program maintenance.

Applicable for

Power supply

Weight

Dimensions (WxHxD)

Order information

Base units FX3U

5 V DC (from base unit) kg 0.02

mm 19.6x46.1x53.5

Art. no. 165284

Expansion Adapters

FX

3G

-CNV

-ADP

þ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

¨ FX 3UC

Expansion Adapters FX 1N -CNV-BD, FX 3G -CNV-ADP, FX 3U -CNV-BD

The below listed expansion adapters enable the connection of the adapter modules

FX

첸첸

-

첸첸첸

ADP on the left hand side of the FX1N, FX3G and FX3U base units.

Applicable for

Weight

Dimensions (WxH)

Order information

Base units FX1S/FX1N kg 0.01

mm 43x38x(D)14

Art. no. 130745

FX3G-CNV-ADP

Base units FX3G

0.1

90x14.6x(D)86

221268

Base units FX3U

0.01

19.6x46.1x(D)53.5

165285

FX3G-CNV-ADP

48 MITSUBISHI ELECTRIC

Interface Adapters

FX3U-232-BD

FX3G-232-BD

FX3U-422-BD

FX3G-422-BD

INTERFACE

ADAPTERS

///

þ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

¨ FX 3UC

Interface Adapters FX 1N -232-BD, FX 3G -232-BD, FX 3U -232-BD

The FX 첸첸 -232-BD interface adapters provide an RS232C interface for serial data communications with the MELSEC FX 1S /FX 1N /FX 3G /FX 3U .

Applicable for

Interface

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

Order information

Base units FX1S/FX1N

FX3G-232-BD

Base units FX3G

RS232C with 9 pole D-SUB connector

5 V DC/20 mA (from base unit)

— kg 0.02

mm 43x38.5x22

0.02

35x51.2x17.2

Art. no. 130743 221254

FX3U-232-BD

Base units FX3U

5 V DC/20 mA

(from base unit)

0.02

19.3x46.1x62.7

165281

Interface Adapters FX 1N -422-BD, FX 3G -422-BD, FX 3U -422-BD

The FX 첸첸 -422-BD interface adapters provide a second RS422 interface for connection of an additional device to the controller (programming unit or operator terminal).

Applicable for

Interface

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

Order information

Base units FX1S/FX1N

FX3G-422-BD

Base units FX3G

RS422 with 8 pole mini DIN connector

5 V DC/60 mA

(from base unit)

5 V DC/20 mA (from base unit)

FX3U-422-BD

Base units FX3U

— kg 0.01

mm 43x38.5x20

0.02

35x51.2x14.9

0.02

19.6x46.1x53.5

Art. no. 130741 221252 165282

4

FX3U-485-BD

FX3G-485-BD

Interface Adapters FX 1N -485-BD, FX 3G -485-BD, FX 3U -485-BD

The interface adapters FX 첸첸 -485-BD provide the controller with an additional RS485 interface. The adapter, which is simply inserted into the base unit’s expansion slot, enables the configuration of RS485 1:n multidrop, parallel link or peer-to-peer networks with FX 1S /FX 1N /FX 3G /FX 3U systems.

Applicable for

Interface

Power supply

Related I/O points

Weight

Dimensions (WxHxD)

Order information

Base units FX1S/FX1N

RS485/RS422

5 V DC/60 mA

(from base unit)

— kg 0.02

mm 43x38.5x22

Art. no. 130742

FX3G-485-BD

Base units FX3G

5 V DC/20 mA

(from base unit)

0.02

35x51.2x29.2

221253

FX3U-485-BD

Base units FX3U

5 V DC/40 mA

(from base unit)

0.02

19.6x46.1x69

165283

MITSUBISHI ELECTRIC 49

///

EXPANSION

ADAPTER/

MEMORY

CASSETTES

Expansion Adapter

FX

2NC

-CNV-IF

¨ FX 1S

¨ FX 1N

¨ FX 3G

¨ FX 3U

þ FX 3UC

FX 2NC -CNV-IF

The FX2NC-CNV-IF expansion adapter connects FX3UC main units with the standard

FX0N/FX2N/FX3U right side expansion bus.

Bus connection

Weight

Dimensions (WxHxD)

Order information

FX3UC bus to FX0N/FX2N/FX3U bus kg 0.3

mm 90x 4.6x74

Art. no. 104508

FX2NC-CNV-IF

5

Memory Media

WR

RD

8L PLC

ON

PROTECT

SW

OFF

8L PLC

FX1N-EEPROM-8L

þ FX 1S

þ FX 1N

þ FX 3G

¨ FX 3U

¨ FX 3UC

Memory cassettes for FX 1S , FX 1N and FX 3G

All FX 1S , FX 1N and FX 3G base units are equipped with a slot for the optional, robust FX memory cassettes. By connection of these memory cassettes, the internal memory of the controller is switched off and only the program specified in the respective memory cassette is run.

The memory cassettes can upload/download programs to and from the FX PLC internal memory with the help of 2 buttons.

The memory cassette FX3G-EEPROM-32L can also be placed on top of the standard BD expansion boards.

Applicable for

Memory type

Size

Protect switch

Data transfer buttons

Order information

Base units FX1S/FX1N

EEPROM

2000/8000 steps

Provided

Provided

Art. no. 130746

FX3G-EEPROM-32L

Base units FX3G

EEPROM

32000 steps

Provided

Provided

221269

FX3G-EEPROM-32L

Memory Media

¨

FX 1S

¨

FX 1N

¨

FX 3G

þ

FX 3U

þ

FX 3UC

Memory Cassettes for FX 3U /FX 3UC

The memory cassette can be installed at the main unit, and when installed, the memory cassette’s internal program is used in place of the internal RAM memory.

The FX 3U -FLROM-64L features additional data transfer buttons.

50

FX3U-FLROM-64L

Applicable for

Number of steps

Memory type

Protect switch

Data transfer buttons

Dimensions (WxHxD)

Order information

Base units FX3U/FX3UC

16,000

Flash memory

Provided

Not provided mm 37x20x6.1

Art. no. 165278

Base units FX3U/FX3UC

64,000

Flash memory

Provided

Not provided

37x20x6.1

165279

Base units FX3U/FX3UC

64,000

Flash memory

Provided

Provided

37x20x6.1

165280

MITSUBISHI ELECTRIC

EXTERNAL

TERMINAL

BLOCKS

///

Terminal Blocks

2 4 6 8 10 12 14 16 18 20

TB-20C

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

These terminal blocks are adapter modules that simplify the wiring of the inputs and outputs of the FX3UC main units with ribbon cable connectors. This practical, time-saving wiring system also improves the performance of the outputs. Special terminal blocks are also available for the FX3U/FX3UC positioning modules with ribbon cable connectors.

Input blocks, output blocks and combined I/O blocks are available, with a choice of different terminal types.

The TB-

EX

쏔 input blocks are fitted with rows of bridged connectors for 24V/0V terminals, which make wiring quick and easy.

The TB-8EY-S and TB-8EY-C output blocks consist of 8 standard terminals and a system adapter. The standard terminals can be populated with relay or transistor elements, which makes it possible to configure the system for much higher output currents.

Preconfigured system cabling is available for all the terminal blocks (see next page).

TB-

.0

.1

.2

.3

.4

.5

.6

.7

EX

Type

Integrated inputs

Design

Connection type

Application

Dimensions (WxHxD)

Order information

Accessories

Input block

8

TB-8EX-C

Input block

8

Initiator module with potential terminals

TB-16EX-S

Input block

16

Screw terminals Spring terminals Screw terminals

FX2NC series base and extension modules with connectors mm 75x45x54 75x45x63 116x45x54

Art. no. 149144 149145

Connection Cable (see following page)

149021

Socket

Power supply terminal

.0

.1

.2

24V+

.3

-

.4

.5

.6

.7

PLC-V8/FLK14/OUT

Art. 22 95 55 4

System adapter

Base terminal

A2A2-

A2A2-

A2A2-

A2A2-

24

V

24

V

24

V

24

V

24

V

24

V

24

V

24

V

TB-

EY

Type

Channels

Design

Connection type

Application

Dimensions (WxHxD)

Output block

8

TB-8EY-C

Output block

8

Socket for relay or transistor elements

Screw terminals Spring terminals

FX2NC series base and extension modules with connectors mm 49.6x100x94

Order information Art. no. 149044

49.6x100x94

149045

Accessories

Pluggable function elements (see below),

Connection cable (see following page)

TB-16EX-C

Input block

16

Spring terminals

116x45x63

149022

TB-20-S

Input/output block

8/16

20 pin terminal module

Screw terminals

TB-20C

Input/output block

8/16

Spring terminals

FX2N series positioning module

75x45x52

149148

75x45x52

149023

Connection cable (see following page)

5

Catch

Contact for plug-in strip bridge

Terminal opertion aperture

LED status display

Inserted relay or transistor element

Notch lever for securing and ejecting

The transistor and relay elements are plugged directly into the standard terminals in the

TB-8EY-S or TB-8EY-C modules. All the elements feature a status LED, protection against reverse polarity connection and a freewheeling diode.

Neighbouring terminals with identical voltages can be connected with plug-in strip bridge connectors, which can be cut to length as required.

Output type

Number of elements

Relay with 1 switch-over contact

8

Rated input voltage 24 V DC

Switching voltage (min./max.) 12 V AC/DC; 250 V AC/DC

Limit permanent current

Max. breaking capacity

Ambient temperature

6 A

140 W (24 V DC), 1500 VA (250 V AC)

-20–+60 °C

Transistor (with optocoupler)

8

24 V DC

3 V DC; 33 V DC

3 A (at 20 °C), 2 A (at 60 °C)

-20–+60 °C

Order information Art. no. 149034 (set with 8 elements)

Accessories

149035 (set with 8 elements)

Insulated infinite pin bridge for potential isolation, TB-PIB-RD, color red, art.-no.: 149146;

Insulated infinite pin bridge for potential isolation, TB-PIB-BL, color blue art.-no.: 149147;

Isolation plate TB-SP for lateral base terminal connection, art.-no.: 149158

MITSUBISHI ELECTRIC 51

///

EXTERNAL

TERMINAL

BLOCKS

5

Terminal Connection Cable ¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

These preconfigured cables enable quick, error-free wiring of the terminal blocks of the positioning modules for the FX 3U and FX 3UC series fitted with ribbon cable connectors.

The cables are available in a choice of lengths between 1 and 5 m. Other lengths are also possible by special order.

Application

Length

For TB-20m 1

Order information Art. no. 149038

(1:1 cable)

3

149039

TB-EX-CAB-5M

5

149040

Application

Length

For 2 x terminal blocks TB-8EY-S or TB-8EY-C (Y cable) m 1

Order information Art. no. 149041

3

149042

TB-EY-CAB-5M

5

149043

Connection terminals ¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

The base unit FX 2NC -16MR-T-DS and the extension units FX 2NC -16EX-T-DS and

FX

2NC

-16EYR-T-DS are fitted with screw terminals as standard equipment.

These plug-in terminals can easily be replaced with spring terminals if required.

Two replacement terminal units are required for each module with 16 I/Os.

Number of terminal points

Connection type

Application

TB-CON-5-C

5

Spring terminals

Adapter modules

Dimensions (WxHxD) mm 12.5x20x21

Order information Art. no. 221539

10

Spring terminals

Adapter modules and FX2NC-16EX-T-DS /

FX2NC-16EYR-T-DS extension modules

12.5x20x21

149036

52 MITSUBISHI ELECTRIC

POWER

SUPPLIES/

BATTERIES

///

24 V Power Supply Unit

Output DC

24V 1.75 A

Input AC

24V 1.75 A

ALPHA POWER

þ ALPHA þ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

The ALPHA-POWER units are a convenient power supply for 24 V units and other external devices. They come with mounting systemfor wall or DIN rail mounting and their dimensions are matched to those of the ALPHA family.

Up to 5 power supply units can be installed together for redundant mode operation or connected in parallel for more power. The units have an integrated thermal overload protection circuit and a POWER LED. The output voltage is adjustable.

Application

General specifications

Nominal input voltage

Output voltage

Nominal output current

Max. output current

Ambient temperature

Ambient humidity

Weight

Dimensions (WxHxD)

Order information

ALPHA POWER 24-1.75

ALPHA POWER 24-2.5

Power supply for 24 V DC Alpha base units

Conforms to FX family and ALPHA base units

100–240 V (45–65 Hz)

24 V DC (+/-1 %)

0.75 A (at T=55 °C) 1.75 A (at T=55 °C)

1.4 A 3.75 A

-25–+55 °C (operation), -40–+85 °C (storage)

2.5 A (at T=55 °C)

4.4 A

Max. 95 % (no condensation) kg 0.1

0.2

mm 36x90x61 54x90x61

0.3

72x90x61

Art. no. 209029 209030 209031

5 V Power Supply Unit

FX3U-1PSU-5V

FX3UC-1PS-5V

POWER

FX

3UC

-1PS-5V

¨ FX 1S

¨ FX 1N

¨ FX 3G

þ FX 3U

þ FX 3UC

The power supply modules FX 3U -1PSU-5V and FX 3UC -1PS-5V are used to reinforce the build-in 5 V DC and 24 V DC power supply of a FX 3G /FX 3U /FX 3UC main unit. They do not occupy any I/O points and deliver up to 1 A more current for the 5 V system bus (for special function modules).

Up to two FX 3U -1PSU-5V or FX 3UC -1PS-5V modules can be used. Both modules have an integrated overload protection available.

Note: The FX3U-1PSU-5V can't be used with a 24 V base unit!

When connecting an input extension module (incl. FX2N-8ER-ES/UL, FX2N-8ER) to the FX3U-1PSU-5V, supply the power for it from the 24 V DC service power supply of the connected main unit or powered extension unit on the upstream side.

Application

General specifications

Nominal input voltage

Output voltage

Max. output current

Ambient temperature

Ambient humidity

Weight

Dimensions (WxHxD)

Order information

FX3UC-1PS-5V

Power supply for the FX3G/FX3U system bus Power supply for the FX3UC system bus

Conforms to FX family base units

100–240 V (50/60 Hz) 24 V DC (+20 %/-15 %)

5 V DC/24 V DC

5 V DC 1 A at 40 °C; 0.8 A at 55 °C

5 V DC

1 A

24 V DC 0.3 A at 40 °C; 0.2 A at 55 °C —

-25–+55 °C (operation), -40–+85 °C (storage)

Max. 95 % (no condensation) kg 0.3

mm 55x90x87

0.15

24x90x74

Art. no. 169507 210086

Backup Batteries

FX3U-32BL

MITSUBISHI ELECTRIC

¨ FX 1S

¨ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

Batteries

The battery buffers the internal RAM of the MELSEC PLC in the event of a voltage failure.

The battery FX 2NC -32BL is suitable for the positioning modules FX 2N -20GM.

The battery FX 3U -32BL can be used for all base units of the MELSEC FX 3G /FX 3U /FX 3UC series.

Applicable for

Order information

FX2NC-32BL

FX2N-20GM module

Art. no. 128725

FX3U-32BL

Base unit FX3U

165286

53

5

5

///

CABLES

Cables

FX-20P-CAB0

FX-16E-500CAB

FX0N-65EC

þ FX 1S

þ FX 1N

þ FX 3G

þ FX 3U

þ FX 3UC

FX Series connection cables

The cable listed in the following tables are used for FX Series PLC programming, positioning applications, block connections and interface conversion.

Connection cable for RS232C peripherals

Application

Length

Order information

FX2N-1RM to resolver m 5.0

Art. no. 76160

Connection cable for RS-422 peripherals

PC to FX-232AWC-H

3.0

76163

PC to GOT

3.0

124972

Application

Length

Order information

FX-232AWC-H to FX

PLC m 1.5

Art. no. 76094

Connection cable for programming unit

FX-232AWC-H to FX PLC

0.3

25949

Application

Length

Order information

FX-20P-G/FX-30P to FX

PLC FX-20P-E to FX PLC m 1.5

1.5

Art. no. 55917 30815

FX-232AWC-H to FX PLC

1.5

FX-20P-CAB to FX

PLC

0.3

31870

Connection cable for extension bus

Application

Length

Order information

PLC bus cable for two-stage-configuration with extension units FX

첸첸

-

첸첸

ES m 0.65

Art. no. 45348

Interface converter

Application

Dimensions

Order information

USB to RS422 converter m 0.063+3.0

Art. no. 165288

RS422 to RS232C converter

0.25x0.8x0.6

159642

Programming Cables

FX-USB-AW

54

The USB to RS-422 converter FX-USB-AW is used for the connection between the PLC and a serial interface of a personal computer. The converter is devided into 2 parts and thus universally applicable for all

FX-series PLCs.

The SC-09 programming cable is used for the connection between the PLC and a serial interface of a personal computer. The cable is devided into 2 parts and thus universally applicable for all Mitsubishi PLCs.

Connection on PC side

Order information

USB

Art. no. 165288

SC-09

9-pin D-SUB

43393

MITSUBISHI ELECTRIC

DISPLAYS

///

Display Modules

MITSUBISHI

ESC -

+ OK

FX

3G

-5DM

Display Module FX 1N -5DM and FX 3G -5DM

The display modules FX 1N -5DM and FX 3G -5DM are inserted directly with space-saving into the controller and enable monitoring and editing of the data stored in the PLC.

The display module e.g. can be used instead of digital switches and external 7-segment displays in very confined areas.

Applicable for

Display

Power supply

Current consumption

Weight

Dimensions (WxHxD)

Order information

Base units FX1S/FX1N

LCD (with backlight)

5 V DC ±5 % (from base unit) mA 110 kg 0.02

mm 40x32x17

Art. no. 129197

FX3G-5DM

Base units FX3G series

LCD (with backlight)

5 V DC ± 5 % (from base unit) n/a

0.02

49x34x12

221270

CLR FNC

ENT

Control and Display Panel FX-10DM-E

The control and display panel FX-10-DM-E provides a key-oriented user-interface and enables you to monitor and edit process data in the PLC.

The display is arranged in 2 rows of 16 characters each. Functions can be invoked and values can be edited using the panel keys.

Applicable for

Display

Resolution

Power supply

Current consumption

Weight

Dimensions (WxHxD)

Order information

All base units FX1S/FX1N/FX2N/FX3U

LCD (with backlight)

2x16 signs (80x16 pixles)

5 V DC ±5 % (from base unit) mA 220 kg 0.02

mm 96x62x32

Art. no. 132600

5

Panel FX 3U -7DM with built-in holder

FX 3U -7DM-HLD

Control and Display Panel FX 3U -7DM, Holder FX 3U -7DM-HLD

The FX3U-7DM display module can be incorporated in the main unit, or can be installed in the enclosure using the FX3U-7DM-HLD display module holder.

Applicable for

Display

Resolution

Power supply

Current consumption

Extension cable

Weight

Dimensions (WxHxD)

Order information

Base units FX3U

16 letters x 4 lines

5 V DC (from base unit) mA 20

— kg 0.02

mm 48x35x11.5

Art. no. 165268

Base units FX3U

Included

0.01

66.3x41.8x13

165287

MITSUBISHI ELECTRIC

For further control and operator terminals please refer to the technical catalogue HMI.

55

///

DIMENSIONS

ALPHA

Dimensions of the ALPHA series

AL2-14M

-

, AL2-24M

-

6,0

(A) (B)

DC INPUT

MITSUBISHI

ESC

+

-

OK

AL2-10MR-D

52,0 71,2

6,0

6,0

+ (A) (B) 1 2 3 4 5

DC INPUT

6 7 8 9 10 11 12 13 14 15

POWER

24V DC

MITSUBISHI

ESC

+

-

OK

AL2-24MR-D

OUT1 OUT2 OUT3 OUT4

RELAY

OUTPUT

OUT

5 6 7 8 9

124,6

6,0

6

AL2-4EY

, AL2-2DA

53,1

+

EI1

+

EI2

-

MITSUBISHI

+

EI3

+

EI4

-

4EX

24,5

AL2-ASI-BD

53,1

ASI+

ASI-

ASI+

ASI-

24,5

AL2-2PT-ADP, AL2-2TC-ADP

33,5 35,5

+ -

V1+ V1V2+ V2-

POWER

24V DC

CH1

OUTPUT

CH2

0~10V

MITSUBISHI

POWER

200°C

CH1

-50°C Line 200°C

CH2

-50°C Line

AL2-2PT-ADP

PT100 -50~200°C

CH1 CH2

L1+ L1-

I

1L2+ L2-

I

2-

All dimensions in mm

56 MITSUBISHI ELECTRIC

DIMENSIONS

FX1S/FX1N/FX3G

BASE

UNITS

///

Dimensions of Base Units FX 1S

X

X-8

100-240

VAC

L N

S/S

X0

X1

X2

X3

X4

X5

X6

X7

MITSUBISHI

0 1 2 3

4 5 6 7

IN

POWER

RUN

ERROR

24V

0V

COM0

Y0

COM1

Y1

COM2

Y2

Y3

Y4

Y5

OUT

0 1 2 3

4 5

14MR

-ES/UL

2 x ø4,5

Dimensions of Base Units FX 1N

X

X – 8

100-240

VAC

L N

S/S

X0

X1

X2

X3

X4

X5

X6

X7

X10

X11

X12

X13

X14

X15

X16

X17

X20

X21

X22

X23

X24

X25

X26

X27

MITSUBISHI

0 1 2 3 4 5 6 7 10

11 12 13 14 15 16 17 20 21

22 23 24 25 26 27

IN

POWER

RUN

ERROR

24V

0V

COM0

Y0

COM1

Y1

COM2

Y2

Y3 COM3

Y4

Y5

Y6

Y7

0 1 2 3 4 5 6

11 12 13 14 15 16 17

OUT

7 10

COM4

Y10

Y11

Y12

Y13 COM5

Y14

Y15

Y16

Y17

40M

2 x ø4,5

Dimensions of Base Units MELSEC FX 3G

X

X - 8

Z

75

87

FX1S-10MR-DS

FX1S-10MR-ES/UL

FX1S-10MT-DSS

FX1S-14MR-DS

FX1S-14MR-ES/UL

FX1S-14MT-DSS

FX1S-20MR-DS

FX1S-20MR-ES/UL

FX1S-20MT-DSS

FX1S-30MR-DS

FX1S-30MR-ES/UL

FX1S-30MT-DSS

75

100

100

100

60

75

75

X

60

60

60

60

60

90

90

90

90

90

90

90

Y

90

90

90

90

90

All dimensions in mm

49

49

75

49

49

49

75

Z

49

75

49

49

75

FX1N-14MR

왏왏왏

FX1N-14MT

왏왏왏

FX1N-24MR

왏왏왏

FX1N-24MT

왏왏왏

FX1N-40MR

왏왏왏

FX1N-40MT

왏왏왏

FX1N-60MR

왏왏왏

FX1N-60MT

왏왏왏

FX3G-14

FX3G-24

FX3G-40

FX3G-60

X

90

90

90

90

130

130

175

175

All dimensions in mm

X

90

90

130

175

All dimensions in mm

6

ø4,5

MITSUBISHI ELECTRIC 57

6

///

DIMENSIONS

FX3U

BASE

UNITS

AND

ADAPTERS

Dimensions of Base Units FX 3U

22

X

X1

FX 3U

L N

S/S 0V

24V

X0

X1

X2

X3

X4

X5

X6

X7

-16M

03 12

IN

47 56

POWER

RUN

BATT

ERROR

03 12

OUT

47 56

Y0

Y0

Y1

Y1

Y2

Y2

Y3

Y3

Y4

Y4

Y5

Y5

Y6

Y6

Y7

Y7

R

86

Base Units

FX3U-16M

왏왏왏

FX3U-32M

왏왏왏

FX3U-48M

왏왏왏

FX3U-64M

왏왏왏

FX3U-80M

왏왏왏

FX3U-128M

왏왏왏

X

130

150

182

220

285

350

X1

103

123

155

193

258

323

All dimensions in mm

Ø 4.5

Dimensions of Base Units FX 3UC

X

Base Units

FX3UC-16MT/DSS

FX3UC-32MT/DSS

FX3UC-64MT/DSS

FX3UC-96MT/DSS

X

34

34

59.7

85.4

All dimensions in mm

Dimensions of Adapter Modules FX 3U and Extension Adapters

Ø3.2

74 15.5

17.6

FX 3U -4AD-ADP

POWER

53.5

Ø3.2

19.6

Extension Adapters

FX3U-CNV

FX3U-USB

FX3U-485

FX3U-422

FX3U-232

X

15,5

9,2

All dimensions in mm

53.5

X

19.6

58 MITSUBISHI ELECTRIC

DIMENSIONS

FX0N/FX2N

EXTENSION

UNITS

///

Dimensions of Compact Extension Units FX 0N

X

X -10

87

MITSUBISHI

MELSEC FX -24MR-ES

ø4,5

FX0N-40ER-DS

FX0N-40ER-ES/UL

FX0N-40ET-DSS

X

150

150

150

All dimensions in mm

Dimensions of Compact Extension Units and Modular Extension Blocks MELSEC FX 2N

87

ø4,5

Ø4.5

X

IN

3

4

5

6

7

0

1

2

POWER

4

IN

2

3

4

0

1

5

6

7

Compact Extension Units

FX2N-32E

왏왏왏

FX2N-48E

왏왏왏

FX2N-48ER-UA1/UL

X

150

182

220

Modular Extension Blocks

FX2N-8E

왏왏왏

FX2N-16E

왏왏왏

X

43

40

All dimensions in mm

6

Dimensions of Modular Extension Blocks FX 2NC

74 Y X

Power

X0

3

X4

5

1

2

X0

1

6

7

2

3

X4

5

6

7

FX

2NC

-32EX

-DS

2

3

X4

5

6

7

X0

1

2

3

X4

5

6

7

X0

1

Extension Blocks

FX2NC-16EX-DS

FX2NC-16EYT-DSS

FX2NC-16EX-T-DS

FX2NC-16EYR-T-DSS

FX2NC-32EX-DS

FX2NC-32EYT-DSS

X

14.6

14.6

20.2

24.2

26.2

26.2

Y

13

13

15

15

13

13

All dimensions in mm

MITSUBISHI ELECTRIC 59

6

///

DIMENSIONS

SPECIAL

FUNCTION

MODULES

Dimensions of Special Function Modules MELSEC FX 2N

ø4,5

X 87

4

POWER

24 V

A / D

FX0N-3A

FX2N-2DA

FX2N-2AD

FX2N-4DA

FX2N-4AD

FX2N-4AD-TC

FX2N-4AD-PT

FX2N-1HC

FX2N-1PG-E

FX2N-10PG

FX2N-2LC

FX2N-5A

FX2N-232-IF

FX2N-32ASI-M

FX2N-32CCL

FX2N-32CAN

FX2N-64DNET

Special Function Modules FX

0N

/FX

2N

55

43

43

43

43

43

55

55

55

55

55

55

55

55

X

43

43

43

All dimensions in mm

90

75

FX2N-8AD

75

24+ 24-

V1+

V2+

I1+

I2+

COM1 V3+

COM2 V4+

I3+ COM3

I4+ COM4

MITSUBISHI

POWER

RUN

V5+

V6+

I5+

I6+ COM6

COM5 V7+

V8+

I7+

I8+ COM8

COM7

FX2N-32DP-IF

75

L N

COM 24 +

RUN

STOP

MITSUBISHI

POWER

RUN

BF

DIA

ON

OFF

Dimensions of Special Function Modules MELSEC FX 3U /FX 3UC

X 87

ø4,5

4

POWER

24 V

A / D

FX3U-2HC

FX3U-3A-ADP

FX3U-4DA

FX3U-4AD

FX3U-4LC

FX3U-CF-ADP

FX3U-ENET

FX3U-20SSC-H

FX3U-64CCL

FX3U-64DPM

FX3U-1PSU-5V

FX3UC-4AD

FX3UC-1PS-5V

Special Function Modules FX 3U /FX 3UC

55

90

45

55

55

X

55

17.6

55

55

43

55

20.2

24.2

All dimensions in mm

60 MITSUBISHI ELECTRIC

Dimensions of Adapters FX 1N and FX 3G

FX3G-485-BD

FX1N-4EX-BD

43

DIMENSIONS

SPECIAL

FUNCTION

MODULES

///

43

35 X1 X

FX

3G

Extension Adapters

FX3G-1DA-BD

FX3G-232-BD

FX3G-2AD-BD

FX3G-422-BD

FX3G-485-BD

FX3G-8AV-BD

X

14.1

12

14.1

12

14.1

12

X1

15.1

5.2

15.1

2.9

15.1

All dimensions in mm

Dimensions for Terminal Blocks

TB-20-S

75

50

TB-20-C

6

75

TB-8EX-S

75 54

TB-8EX-C

75

63

TB-16EX-S

116

62

TB-16EX-C

54

MITSUBISHI ELECTRIC

All dimensions in mm

61

///

DIMENSIONS

ACCESSORIES

Dimensions for Accessories

FX-485PC-IF

MITSUBISHI

POWER

RD

SD

FX-485PC-IF

SDA SDB RDA RDB LINK SG

100

FX3G-EEPROM-32L

30

FX3U-FLROM-16/64/64L

FX1N-EEPROM-8L

33

WR

RD

8L PLC

ON

PROTECT

SW

OFF

8L PLC

9

37

35 9.6

6

Dimensions for Display Panels

FX1N-5DM

17

11 40

FX3U-7DM

11.5

8.5

ESC + OK

FX-10DM-E

96 32

48

6.1

FX3G-5DM

49.4

MITSUBISHI

DISPLAY MODULE

MODEL

SERIAL

FX-10DM-E

030002 V1.00

MITSUBISHI ELECTRIC CORPORATION

CLR FNC

86

ENT

4,5

62

All dimensions in mm

9.6

12

All dimensions in mm

MITSUBISHI ELECTRIC

PROGRAMMING

///

MELSOFT – Programming and Documentation Software for Standard Personal Computers

With the MELSOFT software family Mitsubishi Electric offers efficient software packages helping to reduce programming and setup times to a high degree. The MELSOFT software family provides instant access, direct communications, compatibility, and open exchange of variables.

The MELSOFT family comprises:

Programming packages AL-PCS/WIN and GX Developer

Various development software for operator terminals (please refer to the

GOT Technical Catalogue )

앬 Software for a dynamic data exchange like MX Change

AL-PCS/WIN is recommended as a cost-effective beginners package for the ALPHA series.

This package offers a quick and easy introduction to programming.

GX Developer is the right decision for a universal programming package.

In addition, GX Developer is fully compatible with all MELSEC PLCs, including A and

Q series controllers.

For detailed information please order our separate MELSOFT brochure.

For structured programming the IEC1131.3 (EN 61131-3) conform programming software

GX IEC Developer is recommended.

ALPHA Programming Software

AL-PCS/WIN Programming Software

All controllers of the ALPHA series can be programmed with the MS Windows software

AL-PCS/WIN. Programming the ALPHA with this software is very easy and is done by placing the different program elements on a graphical programming environment. The connections (wiring) between the inputs, function blocks, and outputs are drawn graphically by mouse click to build the logic. By this, programs with up to 200 function blocks can be created, where each single function in a program can be used as many times as desired.

A complete documentation of the program can be created directly from AL-PCS/WIN.

Series

Language

Applicable for

Order information

Alpha series

7 languages (English/German/French/Italian/Spanish/Swedish/Russian)

Windows 95/98/ME/NT/2000/XP/Vista

Art. no. 152603

7

PLC Training Software

FX-TRN-BEG-E Training Software

The FX-TRN-BEG-E training software package is designed to help beginners get started with the programming of PLC systems. It combines a simulated PLC environment with expert tutorials. A real-time module simulates the operation of the PLC program. Simulation speed is adjustable and you can also access system elements and display program status while the process is running.

Series

Language

Applicable for

Order information

Whole FX family

English, Russian

Windows 95/98/ME/NT/2000/XP/Vista

Art. no. 149714

MITSUBISHI ELECTRIC 63

///

PROGRAMMING

PLC Programming Software

GX Developer

Series

Language

Disk type

Order information

Accessory

GX Developer is the standard programming software for all MELSEC PLC series and combines all functions of MELSEC

MEDOC with the user guidance of

Microsoft Windows.

With this software you can comfortably create PLC programs alternatively in the form of Ladder Diagrams or Instruction

Lists. Both forms of representation can be toggled easily during operation.

Besides efficient monitoring and diagnostics functions GX Developer features an offline simulation of any PLC type.

With GX Developer all MELSEC PLCs from the FX 1S to the Q25PH (Q series) are supported.

The GX Developer FX is limited to the programming of the FX series.

This software provides all the Windows-specific advantages and is especially suited to all MELSEC PLCs.

The software is supplied without an SC-09 programming cable, which can be ordered separately. This cable is needed for the connection between the PLC and a serial interface of a personal computer.

GX Developer can be run under MS Windows® XP and Vista.

FX1S, FX1N, FX3G, FX3U, FX3UC

German/English

CD ROM

GX DEVELOPER FX

V0878-2L0C-M_2&MORE

FX1S, FX1N, FX3G, FX3U, FX3UC

German/English

CD ROM

Art. no. 225141 225155

Programming cable SC-09, art. no.: 43393

GX Developer V0800-1LOC-G

All MELSEC PLCs

German

CD ROM

152816

All MELSEC PLCs

English

CD ROM

150420

7

GX IEC Developer

GX IEC Developer provides all functions of the pre-mentioned programs and in addition meets the programming standard:

IEC 1131.3 (EN 61131). This makes the software ready for the programming standard of the future and offers beside the FX version in addition the full version as a basis for the on-leading programming of the MELSEC AnS/QnAS series, the

MELSEC AnU/QnA series and MELSEC System Q.

GX IEC Developer can be run under Windows 95/98 and Windows NT/2000/XP.

The software is supplied without an SC-09 programming cable, which can be ordered separately. This cable is needed for the connection between the PLC and a serial interface of a personal computer.

Series

Language

Disk type

Order information

Accessory

FX1S, FX1N, FX3G, FX3U, FX3UC

German

CD ROM

Art. no. 221425

Programming cable SC-09, art. no.: 43393

FX1S, FX1N, FX3G, FX3U, FX3UC

English

CD ROM

221430

All MELSEC PLCs

German

CD ROM

221413

GX IEC Developer V0703-1LOC-E

All MELSEC PLCs

English

CD ROM

221419

64 MITSUBISHI ELECTRIC

PROGRAMMING

///

Configurations Software

GX Configurator DP

The GX Configurator DP is a user friendly configurations software for the open network

PROFIBUS/DP.

The software package is a 32 bit application and runs under all Windows versions.

Configuration of all PROFIBUS/DP modules for the MELSEC Ans/QnAS and A/Q series and also the FX family is possible.

Due to the supported extended user parameters of a GSD file, easy parameter setting of

PROFIBUS/DP slave devices is possible even for third-party devices.

The new GX Configurator DP enables the download of all configuration data via an overriding network.

All PROFIBUS modules are configured via the backside bus.

Supported PROFIBUS/DP master modules for the Mitsubishi MELSEC series

Language

Disk type

Order information

A1SJ71PB92D, AJ71PB92D, QJ71PB92D

English/German

CD ROM

Art. no. 145312

Ac cessory Programming cable SC-09, art. no.: 43393

FX Configurator FP

FX Configurator-FP is beneficial for setting up table operation information, servo amplifier parameters and positioning parameters for the FX3U-SSC-H positioning module. Positioning operations and their associated parameters (speeds, addresses, torque limits etc.) can be monitored and tested with the integrated monitor and test functions.

Control patterns from simple to complicated combinations of positioning commands can easily be configured with new methods.

The software runs under all Windows versions.

7

Supported modules for the Mitsubishi MELSEC series

Language

Disk type

Order information

Accessory

FX3U-20SSC-H

English

CD ROM

Art. no. 189283

Programming cable SC-09, art. no.: 43393

MITSUBISHI ELECTRIC 65

///

PROGRAMMING

7

Hand-Held Programming Unit

STL/MEP

RE

EF

The FX-30P is a small, industrial programming and maintenance tool for the FX Series.

This unit can perform program uploads/downloads and store up to 15 programs in its internal memory. Keywords can be registered, deleted or canceled in applicable PLCs.

Program monitoring and data device adjustment functionality is also available. To stay up to date the latest firmware can be downloaded on a PC then installed via the USB port.

PLC programs on the PC can also be transferred via USB, eliminating the need for peripheral devices.

Note: FX-30P firmware and program downloads from a PC via the embedded USB port available in firmware versions 1.10 and later.

Applicable for

Ambient temperature

Ambient relative humidity

(non-condensing)

Power supply

Display

Character display

Keyboard

Memory

Cable

Weight

Dimensions(WxHxD)

Base units FX1S, FX1N, FX3G, FX2N, FX3U, FX3UC

0–40 °C

5–95 %

Program capacity

HPP held data

5V DC ±5%/155 mA (from main unit)

LCD (with backlight)

21x8

35

Built-in RAM: 64K steps for program monitoring and modification RAM retention (for about five years, ambient temperature 25 C(77 F)) by battery.

Built-in flash memory ROM: Up to 15 programs can be stored in the built-in flash memory

ROM. Allowable number of writes: 100,000 times

Display language setting (Japanese, English or Chinese), contrast, buzzer sound volume, brightness adjustment, screen saver and HPP protect key (saved in the built-in flash memory)

FX-20P-CAB0 kg 0.3

mm 87x170x30

Order information Art. no. 221271

66 MITSUBISHI ELECTRIC

CERTIFICATIONS

///

CE

EMC LVD

ALPHA 2 Base Units

AL2-10MR-A

AL2-10MR-D

AL2-14MR-A

AL2-14MR-D

AL2-24MR-A

AL2-24MR-D

ALPHA Extension Modules

AL2-4EX-A2

AL2-4EX

AL2-4EYR

AL2-4EYT

AL2-2DA

AL2-2PT-ADP

AL2-2TC-ADP

AL2-ASI-BD

FX1S Base Units

FX1S-10MR-DS

FX1S-10MR-ES/UL

FX1S-10MT-DSS

FX1S-14MR-DS

FX1S-14MR-ES/UL

FX1S-14MT-DSS

FX1S-20MR-DS

FX1S-20MR-ES/UL

FX1S-20MT-DSS

FX1S-30MR-DS

FX1S-30MR-ES/UL

FX1S-30MT-DSS

FX1N Base Units

FX1N-14MR-DS

FX1N-14MR-ES/UL

FX1N-14MT-DSS

FX1N-24MR-DS

FX1N-24MR-ES/UL

FX1N-24MT-DSS

FX1N-40MR-DS

FX1N-40MR-ES/UL

FX1N-40MT-DSS

FX1N-60MR-DS

FX1N-60MR-ES/UL

FX1N-60MT-DSS

FX3G Base Units

FX3G-14MR/ES

FX3G-14MT/ESS

FX3G-14MR/DS

FX3G-14MT/DSS

FX3G-24MR/ES

FX3G-24MT/ESS

FX3G-24MR/DS

FX3G-24MT/DSS

FX3G-40MR/ES

FX3G-40MT/ESS

FX3G-40MR/DS

FX3G-40MT/DSS

FX3G-60MR/ES

FX3G-60MT/ESS

FX3G-60MR/DS

FX3G-60MT/DSS

쎲 uL cUL

Ship approvals

ABS DNV LR GL BV RINA

— —

— — — — —

— — —

— — — — —

— — —

CE

EMC LVD

FX3U Base Units

FX3U-16

FX3U-32

FX3U-48

FX3U-64

FX3U-80

FX3U-128

FX3UC Base Units

FX3UC-16MT/DSS

FX3UC-32MT/DSS

FX3UC-64MT/DSS

FX3UC-96MT/DSS

FX0N/FX2N Extension Units

FX0N-40ER-ES/UL

FX0N-40ER-DS

FX0N-40ET-DSS

FX2N-32ER-ES/UL

FX2N-32ET-ESS/UL

FX2N-48ER-DS

FX2N-48ER-ES/UL

FX2N-48ET-DSS

FX2N-48ET-ESS/UL

쎲 uL cUL

FX2N Extension Blocks

FX2N-8ER-ES/UL

FX2N-8EX-ES/UL

FX2N-8EYR-ES/UL

FX2N-8EYT-ESS/UL

FX2N-16EX-ES/UL

FX2N-16EYR-ES/UL

FX2N-16EYT-ESS/UL

FX1N/FX2N Special Function Modules

FX0N-3A

— —

FX0N-32NT-DP

쎲 쑗 쎲

FX2N-1HC

쎲 쎲 쎲

FX2N-1PG-E

쎲 쎲 쎲

FX2N-2AD

쎲 쑗 쎲

FX2N-2DA

쎲 쑗 쎲

FX2N-2LC

쎲 쑗 쎲

FX2N-4AD

쎲 쑗 쎲

FX2N-4AD-TC

쎲 쑗 쎲

FX2N-4AD-PT

쎲 쑗 쎲

FX2N-4DA

쎲 쑗 쎲

FX2N-5A

쎲 쑗 쎲

FX2N-8AD

FX2N-10PG

FX2N-16CCL-M

FX2N-32ASI-M

FX2N-32CAN

FX2N-32CCL

FX2N-32DP-IF

FX2N-64DNET

FX2N-232IF

FX2NC Extension Blocks

FX2NC-16EX-T-DS

FX2NC-16EYR-T-DS

FX2NC-16EX-DS

FX2NC-16EYT-DSS

FX2NC-32-EX-DS

FX2NC-32-EYT-DSS

Ship approvals

ABS DNV LR GL BV RINA

— —

— —

— —

— —

— —

— —

— —

쎲 쎲

쎲 쎲

— —

쎲 쎲

— —

쎲 쎲

— — — —

— — — —

— — —

— — —

쎲 쎲 쎲

— — — —

— —

쎲 쎲 쎲 쎲

— — —

— — — —

쎲 쎲 쎲 쎲

— — —

— — — —

— — — —

— — — —

— — — —

— — — —

— —

— — — —

쎲 쎲 쎲 쎲

= comply,

= no need to comply

— —

— —

— —

— —

— —

— —

— —

쎲 쎲

쎲 쎲

— —

쎲 쎲

— —

— —

— —

— —

쎲 쎲

— —

— —

— —

— —

— —

— —

— —

— —

쎲 쎲

쎲 쎲

— —

— —

— —

쎲 쎲

— —

— —

— —

— —

— —

— —

— —

쎲 쎲

MITSUBISHI ELECTRIC 67

///

CERTIFICATIONS

CE

EMC LVD uL cUL

FX2NC Special Function Modules

FX2NC-485ADP

FX2NC-232ADP

FX2NC-ENET-ADP

— — —

— — —

쑗 쎲

FX2NC-1HC

쎲 쑗 쎲

— —

Ship approvals

ABS DNV LR

GL

BV

RINA

FX3U Special Function Modules

FX3U-2HC

쎲 쑗

FX3U-3A-ADP

FX3U-4AD

FX3U-4DA

FX3U-4AD-TC-ADP

FX3U-4AD-PT-ADP

FX3U-4AD-PNK-ADP

FX3U-4AD-Ptw-ADP

FX3U-4AD-ADP

FX3U-4DA-ADP

FX3U-4HSX-ADP

FX3U-4LC

FX3U-CF-ADP

FX3U-2HSY-ADP

FX3U-20SSC-H

FX3U-485ADP-MB

FX3U-232ADP-MB

FX3U-ENET

FX3U-64DP-M

FX3U-64CCL

— —

— — —

— — —

Adapter Boards

FX1N-1DA-BD

FX1N-2AD-BD

FX1N-2EYT-BD

FX1N-4EX-BD

FX1N-8AV-BD

FX1N-232-BD

FX1N-422-BD

FX1N-485-BD

FX1N-CNV-BD

FX2N-8AV-BD

FX2N-232-BD

FX2N-422-BD

FX2N-485-BD

FX2N-CNV-BD

FX3G-1DA-BD

FX3G-2AD-BD

FX3G-8AV-BD

FX3G-232-BD

FX3G-422-BD

FX3G-485-BD

FX3U-232-BD

FX3U-422-BD

FX3U-485-BD

FX3U-CNV-BD

FX3U-USB-BD

— — —

— — —

쎲 쎲

쎲 쎲

쎲 쎲

쎲 쎲

— —

— — —

— — —

쎲 쎲 쎲

CE

EMC LVD uL cUL

Ship approvals

ABS DNV LR GL BV RINA

Terminal Blocks

TB-20S

TB-20C

Accessories

ALPHA POWER 24

FX1N-5DM

FX-10DM-E

FX-20 P-E-SET0

FX-USB-AW

FX-232AWC-H

FX2N-CNV-IF

FX2N-CNV-BC

FX2NC-CNV-IF

FX3U-1PSU-5V

FX3UC-1PS-5V

FX3U-7DM

FX3U-7DM-HLD

— — — —

— — — —

— — — —

— — — —

— — — —

— — — —

쎲 쎲

— — —

— — —

쎲 쑗

— —

— — — —

= comply,

= no need to comply

— —

— —

— —

— —

— —

— —

— —

— —

— —

— —

— —

— —

쎲 쎲

— —

68 MITSUBISHI ELECTRIC

INDEX

///

A

AL-232CAB . . . . . . . . . . . . . . . . . . . . . . . 12

AL2-10MR-A . . . . . . . . . . . . . . . . . . . . . . . 9

AL2-10MR-D . . . . . . . . . . . . . . . . . . . . . . . 9

AL2-14MR-A . . . . . . . . . . . . . . . . . . . . . . . 9

AL2-14MR-D . . . . . . . . . . . . . . . . . . . . . . . 9

AL2-24MR-A . . . . . . . . . . . . . . . . . . . . . . . 9

AL2-24MR-D . . . . . . . . . . . . . . . . . . . . . . . 9

AL2-2DA . . . . . . . . . . . . . . . . . . . . . . . . . 11

AL2-2PT-ADP. . . . . . . . . . . . . . . . . . . . . . 11

AL2-2TC-ADP . . . . . . . . . . . . . . . . . . . . . 11

AL2-4EX . . . . . . . . . . . . . . . . . . . . . . . . . 11

AL2-4EX-A2 . . . . . . . . . . . . . . . . . . . . . . 11

AL2-4EYR . . . . . . . . . . . . . . . . . . . . . . . . 11

AL2-4EYT . . . . . . . . . . . . . . . . . . . . . . . . 11

AL2-ASI-BD . . . . . . . . . . . . . . . . . . . . . . . 12

AL2-EEPROM-2 . . . . . . . . . . . . . . . . . . . . 12

AL2-GSM-CAB . . . . . . . . . . . . . . . . . . . . . 12

ALPHA 2 series

Accessories . . . . . . . . . . . . . . . . . . . . . 12

Base units . . . . . . . . . . . . . . . . . . . . . . . 9

Dimensions . . . . . . . . . . . . . . . . . . . . . 56

Extension modules . . . . . . . . . . . . . . . . 11

Interface Cable. . . . . . . . . . . . . . . . . . . 12

Memory Cassette . . . . . . . . . . . . . . . . . 12

Specifications . . . . . . . . . . . . . . . . . . . 10

System description. . . . . . . . . . . . . . . . . 8

ALPHA POWER 24-0.75 . . . . . . . . . . . . . . . 53

ALPHA POWER 24-1.75 . . . . . . . . . . . . . . . 53

ALPHA POWER 24-2.5 . . . . . . . . . . . . . . . . 53

Accessories

Batteries . . . . . . . . . . . . . . . . . . . . . . . 53

Cables . . . . . . . . . . . . . . . . . . . . . . . . 52

Connection terminals . . . . . . . . . . . . . . 52

Display modules. . . . . . . . . . . . . . . . . . 55

Programming Cables . . . . . . . . . . . . . . 54

Terminal blocks . . . . . . . . . . . . . . . . . . 51

Active data modules . . . . . . . . . . . . . . . . . 45

Adapter boards . . . . . . . . . . . . . . . . . . . . 47

Analog modules. . . . . . . . . . . . . . . . . . . . 33

Dimensions . . . . . . . . . . . . . . . . . . . . . 60

C

Cables . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Connection Cable . . . . . . . . . . . . . . . . . . . 52

Modules . . . . . . . . . . . . . . . . . . . . . . . 54

Terminal blocks . . . . . . . . . . . . . . . . . . 52

D

Data logger module . . . . . . . . . . . . . . . . . 36

Dimensions . . . . . . . . . . . . . . . . . . . . . . . 56

Display Modules. . . . . . . . . . . . . . . . . . . . 55

E

Extension Adapter Boards . . . . . . . . . . . . . 46

Extensions

ALPHA 2 Series. . . . . . . . . . . . . . . . . . . 11

Dimensions . . . . . . . . . . . . . . . . . . . . . 59

FX series . . . . . . . . . . . . . . . . . . . . . . . 26

External Terminal Blocks . . . . . . . . . . . . . . 51

F

F2-232CAB-1. . . . . . . . . . . . . . . . . . . . . . 54

F2-RS-5CAB. . . . . . . . . . . . . . . . . . . . . . . 54

FX Configurator FP . . . . . . . . . . . . . . . . . . 65

FX-10DM-E . . . . . . . . . . . . . . . . . . . . . . . 55

FX-20P-CAB. . . . . . . . . . . . . . . . . . . . . . . 54

FX-20P-CAB0. . . . . . . . . . . . . . . . . . . . . . 54

FX-20P-CADP. . . . . . . . . . . . . . . . . . . . . . 54

FX-232AWC-H . . . . . . . . . . . . . . . . . . . . . 54

FX-232CAB-1. . . . . . . . . . . . . . . . . . . . . . 54

FX-422CAB . . . . . . . . . . . . . . . . . . . . . . . 54

FX-422CAB-150 . . . . . . . . . . . . . . . . . . . . 54

FX-422CAB0 . . . . . . . . . . . . . . . . . . . . . . 54

FX-USB-AW . . . . . . . . . . . . . . . . . . . . . . . 54

FX0N-32NT-DP. . . . . . . . . . . . . . . . . . . . . 42

FX0N-3A . . . . . . . . . . . . . . . . . . . . . . . . . 34

FX0N-40ER-DS . . . . . . . . . . . . . . . . . . . . . 29

FX0N-40ER-ES/UL . . . . . . . . . . . . . . . . . . 29

FX0N-40ET-DSS . . . . . . . . . . . . . . . . . . . . 29

FX0N-65EC . . . . . . . . . . . . . . . . . . . . . . . 54

FX1N series

Base units . . . . . . . . . . . . . . . . . . . . . . 17

Specifications . . . . . . . . . . . . . . . . . . . 18

System description . . . . . . . . . . . . . . . . 16

FX1N-14MR-DS . . . . . . . . . . . . . . . . . . . . 17

FX1N-14MR-ES/UL . . . . . . . . . . . . . . . . . . 17

FX1N-14MT-DSS. . . . . . . . . . . . . . . . . . . . 17

FX1N-1DA-BD . . . . . . . . . . . . . . . . . . . . . 47

FX1N-232-BD . . . . . . . . . . . . . . . . . . . . . 49

FX1N-24MR-DS . . . . . . . . . . . . . . . . . . . . 17

FX1N-24MR-ES/UL . . . . . . . . . . . . . . . . . . 17

FX1N-24MT-DSS. . . . . . . . . . . . . . . . . . . . 17

FX1N-2AD-BD . . . . . . . . . . . . . . . . . . . . . 47

FX1N-2EYT-BD . . . . . . . . . . . . . . . . . . . . . 46

FX1N-40MR-DS . . . . . . . . . . . . . . . . . . . . 17

FX1N-40MR-ES/UL . . . . . . . . . . . . . . . . . . 17

FX1N-40MT-DSS. . . . . . . . . . . . . . . . . . . . 17

FX1N-422-BD . . . . . . . . . . . . . . . . . . . . . 49

FX1N-485-BD . . . . . . . . . . . . . . . . . . . . . 49

FX1N-4EX-BD. . . . . . . . . . . . . . . . . . . . . . 46

FX1N-5DM . . . . . . . . . . . . . . . . . . . . . . . 55

FX1N-60MR-DS . . . . . . . . . . . . . . . . . . . . 17

FX1N-60MR-ES/UL . . . . . . . . . . . . . . . . . . 17

FX1N-60MT-DSS. . . . . . . . . . . . . . . . . . . . 17

FX1N-8AV-BD . . . . . . . . . . . . . . . . . . . . . 48

FX1N-CNV-BD . . . . . . . . . . . . . . . . . . . . . 48

FX1N-EEPROM-8L. . . . . . . . . . . . . . . . . . . 50

FX1S series

Base units . . . . . . . . . . . . . . . . . . . . . . 14

Specifications . . . . . . . . . . . . . . . . . . . 15

System description . . . . . . . . . . . . . . . . 13

FX1S-10MR-DS . . . . . . . . . . . . . . . . . . . . 14

FX1S-10MR-ES/UL . . . . . . . . . . . . . . . . . . 14

FX1S-10MT-DSS . . . . . . . . . . . . . . . . . . . . 14

FX1S-14MR-DS . . . . . . . . . . . . . . . . . . . . 14

FX1S-14MR-ES/UL . . . . . . . . . . . . . . . . . . 14

FX1S-14MT-DSS . . . . . . . . . . . . . . . . . . . . 14

FX1S-20MR-DS . . . . . . . . . . . . . . . . . . . . 14

FX1S-20MR-ES/UL . . . . . . . . . . . . . . . . . . 14

FX1S-20MT-DSS . . . . . . . . . . . . . . . . . . . . 14

FX1S-30MR-DS . . . . . . . . . . . . . . . . . . . . 14

FX1S-30MR-ES/UL . . . . . . . . . . . . . . . . . . 14

FX1S-30MT-DSS . . . . . . . . . . . . . . . . . . . . 14

FX2N-10PG . . . . . . . . . . . . . . . . . . . . . . . 38

FX2N-16CCL-M. . . . . . . . . . . . . . . . . . . . . 39

FX2N-16EX-ES/UL . . . . . . . . . . . . . . . . . . 31

FX2N-16EYR-ES/UL. . . . . . . . . . . . . . . . . . 31

FX2N-16EYT-ESS/UL . . . . . . . . . . . . . . . . . 31

FX2N-1HC . . . . . . . . . . . . . . . . . . . . . . . . 37

FX2N-1PG-E . . . . . . . . . . . . . . . . . . . . . . 38

FX2N-232IF . . . . . . . . . . . . . . . . . . . . . . . 46

FX2N-2AD . . . . . . . . . . . . . . . . . . . . . . . . 33

FX2N-2DA . . . . . . . . . . . . . . . . . . . . . . . . 33

FX2N-2LC . . . . . . . . . . . . . . . . . . . . . . . . 34

FX2N-32ASI-M. . . . . . . . . . . . . . . . . . . . . 40

FX2N-32CAN . . . . . . . . . . . . . . . . . . . . . . 44

FX2N-32CCL . . . . . . . . . . . . . . . . . . . . . . 40

FX2N-32DP-IF . . . . . . . . . . . . . . . . . . . . . 43

FX2N-32DP-IF-D. . . . . . . . . . . . . . . . . . . . 43

FX2N-32ER-ES/UL . . . . . . . . . . . . . . . . . . 30

FX2N-32ET-ESS/UL . . . . . . . . . . . . . . . . . . 30

FX2N-48ER-DS . . . . . . . . . . . . . . . . . . . . . 30

FX2N-48ER-ES/UL . . . . . . . . . . . . . . . . . . 30

FX2N-48ET-DSS . . . . . . . . . . . . . . . . . . . . 30

FX2N-48ET-ESS/UL . . . . . . . . . . . . . . . . . . 30

FX2N-4AD . . . . . . . . . . . . . . . . . . . . . . . . 33

FX2N-4AD-PT . . . . . . . . . . . . . . . . . . . . . 34

FX2N-4AD-TC. . . . . . . . . . . . . . . . . . . . . . 34

FX2N-4DA . . . . . . . . . . . . . . . . . . . . . . . . 33

FX2N-5A . . . . . . . . . . . . . . . . . . . . . . . . . 34

FX2N-64DNET . . . . . . . . . . . . . . . . . . . . . 44

FX2N-8AD . . . . . . . . . . . . . . . . . . . . . . . . 33

FX2N-8ER-ES/UL . . . . . . . . . . . . . . . . . . . 31

FX2N-8EX-ES/UL . . . . . . . . . . . . . . . . . . . 31

FX2N-8EYR-ES/UL . . . . . . . . . . . . . . . . . . 31

FX2N-8EYT-ESS/UL . . . . . . . . . . . . . . . . . . 31

FX2NC-16EX-DS . . . . . . . . . . . . . . . . . . . . 32

FX2NC-16EX-T-DS. . . . . . . . . . . . . . . . . . . 32

FX2NC-16EYR-T-DS. . . . . . . . . . . . . . . . . . 32

FX2NC-16EYT-DSS . . . . . . . . . . . . . . . . . . 32

FX2NC-1HC . . . . . . . . . . . . . . . . . . . . . . . 37

FX2NC-232ADP . . . . . . . . . . . . . . . . . . . . 45

FX2NC-32BL . . . . . . . . . . . . . . . . . . . . . . 53

FX2NC-32EX-DS . . . . . . . . . . . . . . . . . . . . 32

FX2NC-32EYT-DSS . . . . . . . . . . . . . . . . . . 32

FX2NC-485ADP . . . . . . . . . . . . . . . . . . . . 45

FX2NC-CNV-IF . . . . . . . . . . . . . . . . . . . . . 50

FX2NC-ENET-ADP . . . . . . . . . . . . . . . . . . . 41

FX3G series

Base units . . . . . . . . . . . . . . . . . . . . . . 20

Specifications . . . . . . . . . . . . . . . . . . . 21

System description . . . . . . . . . . . . . . . 19

FX3G-14MR/DS . . . . . . . . . . . . . . . . . . . . 20

FX3G-14MR/ES . . . . . . . . . . . . . . . . . . . . 20

FX3G-14MT/DSS. . . . . . . . . . . . . . . . . . . . 20

FX3G-14MT/ESS . . . . . . . . . . . . . . . . . . . . 20

FX3G-1DA-BD . . . . . . . . . . . . . . . . . . . . . 47

FX3G-232-BD. . . . . . . . . . . . . . . . . . . . . . 49

FX3G-24MR/DS . . . . . . . . . . . . . . . . . . . . 20

FX3G-24MR/ES . . . . . . . . . . . . . . . . . . . . 20

FX3G-24MT/DSS. . . . . . . . . . . . . . . . . . . . 20

FX3G-24MT/ESS . . . . . . . . . . . . . . . . . . . . 20

FX3G-2AD-BD . . . . . . . . . . . . . . . . . . . . . 47

FX3G-40MR/DS . . . . . . . . . . . . . . . . . . . . 20

FX3G-40MR/ES . . . . . . . . . . . . . . . . . . . . 20

FX3G-40MT/DSS. . . . . . . . . . . . . . . . . . . . 20

FX3G-40MT/ESS . . . . . . . . . . . . . . . . . . . . 20

FX3G-422-BD. . . . . . . . . . . . . . . . . . . . . . 49

FX3G-485-BD. . . . . . . . . . . . . . . . . . . . . . 49

FX3G-5DM . . . . . . . . . . . . . . . . . . . . . . . 55

FX3G-60MR/DS . . . . . . . . . . . . . . . . . . . . 20

FX3G-60MR/ES . . . . . . . . . . . . . . . . . . . . 20

FX3G-60MT/DSS. . . . . . . . . . . . . . . . . . . . 20

FX3G-60MT/ESS . . . . . . . . . . . . . . . . . . . . 20

FX3G-8AV-BD . . . . . . . . . . . . . . . . . . . . . 48

FX3G-CNV-ADP . . . . . . . . . . . . . . . . . . . . 48

FX3G-EEPROM-32L . . . . . . . . . . . . . . . . . . 50

FX3U series

Base units . . . . . . . . . . . . . . . . . . . . . . 23

Specifications . . . . . . . . . . . . . . . . . . . 25

System description . . . . . . . . . . . . . . . . 22

FX3U-128MR/ES . . . . . . . . . . . . . . . . . . . 24

FX3U-128MT/ESS . . . . . . . . . . . . . . . . . . . 24

FX3U-16MR/DS . . . . . . . . . . . . . . . . . . . . 23

FX3U-16MR/ES . . . . . . . . . . . . . . . . . . . . 23

FX3U-16MT/DSS. . . . . . . . . . . . . . . . . . . . 23

FX3U-16MT/ESS . . . . . . . . . . . . . . . . . . . . 23

FX3U-1PSU-5V. . . . . . . . . . . . . . . . . . . . . 53

FX3U-20SSC-H . . . . . . . . . . . . . . . . . . . . 38

FX3U-232-BD . . . . . . . . . . . . . . . . . . . . . 49

FX3U-232ADP . . . . . . . . . . . . . . . . . . . . . 45

FX3U-2HC . . . . . . . . . . . . . . . . . . . . . . . . 37

FX3U-2HSY-ADP. . . . . . . . . . . . . . . . . . . . 37

FX3U-32BL . . . . . . . . . . . . . . . . . . . . . . . 53

FX3U-32DP . . . . . . . . . . . . . . . . . . . . . . . 43

FX3U-32MR/DS . . . . . . . . . . . . . . . . . . . . 23

FX3U-32MR/ES . . . . . . . . . . . . . . . . . . . . 23

FX3U-32MT/DSS. . . . . . . . . . . . . . . . . . . . 23

FX3U-32MT/ESS . . . . . . . . . . . . . . . . . . . . 23

FX3U-3A-ADP . . . . . . . . . . . . . . . . . . . . . 34

FX3U-422-BD . . . . . . . . . . . . . . . . . . . . . 49

FX3U-485-BD . . . . . . . . . . . . . . . . . . . . . 49

FX3U-485ADP-MB . . . . . . . . . . . . . . . . . . 45

FX3U-48MR/DS . . . . . . . . . . . . . . . . . . . . 24

FX3U-48MR/ES . . . . . . . . . . . . . . . . . . . . 24

FX3U-48MT/DSS. . . . . . . . . . . . . . . . . . . . 24

FX3U-48MT/ESS . . . . . . . . . . . . . . . . . . . . 24

FX3U-4AD . . . . . . . . . . . . . . . . . . . . . . . . 33

FX3U-4AD-ADP . . . . . . . . . . . . . . . . . . . . 35

FX3U-4AD-PNK-ADP . . . . . . . . . . . . . . . . . 35

FX3U-4AD-PT-ADP . . . . . . . . . . . . . . . . . . 35

FX3U-4AD-PTW-ADP . . . . . . . . . . . . . . . . 35

FX3U-4AD-TC-ADP . . . . . . . . . . . . . . . . . . 35

FX3U-4DA . . . . . . . . . . . . . . . . . . . . . . . . 33

FX3U-4DA-ADP . . . . . . . . . . . . . . . . . . . . 35

FX3U-4HSX-ADP. . . . . . . . . . . . . . . . . . . . 37

FX3U-4LC . . . . . . . . . . . . . . . . . . . . . . . . 36

FX3U-64CCL . . . . . . . . . . . . . . . . . . . . . . 39

FX3U-64DP-M . . . . . . . . . . . . . . . . . . . . . 42

FX3U-64MR/DS . . . . . . . . . . . . . . . . . . . . 24

FX3U-64MR/ES . . . . . . . . . . . . . . . . . . . . 24

FX3U-64MT/DSS. . . . . . . . . . . . . . . . . . . . 24

FX3U-64MT/ESS . . . . . . . . . . . . . . . . . . . . 24

FX3U-7DM . . . . . . . . . . . . . . . . . . . . . . . 55

FX3U-7DM-HLD . . . . . . . . . . . . . . . . . . . . 55

FX3U-80MR/DS . . . . . . . . . . . . . . . . . . . . 24

FX3U-80MR/ES . . . . . . . . . . . . . . . . . . . . 24

FX3U-80MT/DSS. . . . . . . . . . . . . . . . . . . . 24

FX3U-80MT/ESS . . . . . . . . . . . . . . . . . . . . 24

FX3U-CF-ADP . . . . . . . . . . . . . . . . . . . . . 36

FX3U-CNV-BD . . . . . . . . . . . . . . . . . . . . . 48

FX3U-ENET . . . . . . . . . . . . . . . . . . . . . . . 41

FX3U-FLROM-16 . . . . . . . . . . . . . . . . . . . 50

FX3U-FLROM-64 . . . . . . . . . . . . . . . . . . . 50

FX3U-FLROM-64L. . . . . . . . . . . . . . . . . . . 50

FX3U-USB-BD . . . . . . . . . . . . . . . . . . . . . 48

FX3UC-16MT/DSS. . . . . . . . . . . . . . . . . . . 27

FX3UC-1PS-5V . . . . . . . . . . . . . . . . . . . . . 53

FX3UC-32MT/DSS. . . . . . . . . . . . . . . . . . . 27

FX3UC-4AD . . . . . . . . . . . . . . . . . . . . . . . 33

FX3UC-64MT/DSS. . . . . . . . . . . . . . . . . . . 27

FX3UC-96MT/DSS. . . . . . . . . . . . . . . . . . . 27

FX3UC-Serie

Base Units . . . . . . . . . . . . . . . . . . . . . . 27

Specifications . . . . . . . . . . . . . . . . . . . 28

System description . . . . . . . . . . . . . . . . 26

G

GX Configurator DP. . . . . . . . . . . . . . . . . . 65

GX Developer. . . . . . . . . . . . . . . . . . . . . . 64

GX IEC Developer . . . . . . . . . . . . . . . . . . . 64

H

High speed counter . . . . . . . . . . . . . . . . . 37

I

Interface Adapters . . . . . . . . . . . . . . . . . . 49

Interface modules . . . . . . . . . . . . . . . . . . 45

M

Memory Media . . . . . . . . . . . . . . . . . . . . 12,

50

N

Network modules. . . . . . . . . . . . . . . . . . . 39

P

Positioning modules. . . . . . . . . . . . . . . . . 38

Power supply units . . . . . . . . . . . . . . . . . . 53

24 V . . . . . . . . . . . . . . . . . . . . . . . . . . 53

5 V . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

S

SC-09 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Sample Calculations . . . . . . . . . . . . . . . . . . 7

Ship approvals . . . . . . . . . . . . . . . . . . . . . 67

Software

AL-PCS/WIN . . . . . . . . . . . . . . . . . . . . 63

FX Configurator FP V0100-1LOC-E . . . . . . 65

FX-TRN-BEG-E . . . . . . . . . . . . . . . . . . . 63

GX Configurator DP V0500-1L0C-E . . . . . 65

GX DEVELOPER FX V0878-1L0C-M . . . . . . 64

GX DEVELOPER FX V0878-2L0C-M_2&MORE 64

GX Developer V0800-1LOC-E . . . . . . . . . 64

GX Developer V0800-1LOC-G . . . . . . . . . 64

Specifications

ALPHA 2 . . . . . . . . . . . . . . . . . . . . . . . . 9

FX1N series . . . . . . . . . . . . . . . . . . . . . 18

FX1S series . . . . . . . . . . . . . . . . . . . . . 15

FX3G . . . . . . . . . . . . . . . . . . . . . . . . . 21

FX3U series . . . . . . . . . . . . . . . . . . . . . 25

FX3UC series . . . . . . . . . . . . . . . . . . . . 28

System description

ALPHA 2 series. . . . . . . . . . . . . . . . . . . . 8

FX1N series . . . . . . . . . . . . . . . . . . . . . 16

FX1S series . . . . . . . . . . . . . . . . . . . . . 13

FX3G Series . . . . . . . . . . . . . . . . . . . . . 19

FX3U series . . . . . . . . . . . . . . . . . . . . . 22

FX3UC series . . . . . . . . . . . . . . . . . . . . 26

MELSEC PLC Systems. . . . . . . . . . . . . . . . 4

T

TB-16EX-C. . . . . . . . . . . . . . . . . . . . . . . . 51

TB-16EX-S. . . . . . . . . . . . . . . . . . . . . . . . 51

TB-20-S . . . . . . . . . . . . . . . . . . . . . . . . . 51

TB-20C . . . . . . . . . . . . . . . . . . . . . . . . . . 51

TB-8EX-C . . . . . . . . . . . . . . . . . . . . . . . . 51

TB-8EX-S. . . . . . . . . . . . . . . . . . . . . . . . . 51

TB-8EY-C. . . . . . . . . . . . . . . . . . . . . . . . . 51

TB-8EY-S. . . . . . . . . . . . . . . . . . . . . . . . . 51

TB-8RELAY-6A . . . . . . . . . . . . . . . . . . . . . 51

TB-8TRANSISTOR-2A. . . . . . . . . . . . . . . . . 51

TB-CON-5-C. . . . . . . . . . . . . . . . . . . . . . . 52

TB-CON10-C . . . . . . . . . . . . . . . . . . . . . . 52

TB-EX-CAB-1M. . . . . . . . . . . . . . . . . . . . . 52

TB-EX-CAB-3M. . . . . . . . . . . . . . . . . . . . . 52

TB-EX-CAB-5M. . . . . . . . . . . . . . . . . . . . . 52

TB-EY-CAB-1M. . . . . . . . . . . . . . . . . . . . . 52

TB-EY-CAB-3M. . . . . . . . . . . . . . . . . . . . . 52

TB-EY-CAB-5M. . . . . . . . . . . . . . . . . . . . . 52

Temperature control module . . . . . . . . . . . 36

MITSUBISHI ELECTRIC 69

70 MITSUBISHI ELECTRIC

Application solutions /// Application solutions /// Application solutions /// Automation solutions /// Automation solutions /// Automation solutions

A world of automation solutions

Robots

Motion control and servos

Inverters

LV circuit protection

Laser machines

CNC controllers

HMI and GOTs

EDM machines

Micro PLCs

Modular PLCs

Mitsubishi offer a wide range of automation equipment from PLCs and HMIs to CNC and EDM machines.

A name to trust

Since its beginnings in 1870, some

45 companies use the Mitsubishi name, covering a spectrum of finance, commerce and industry.

This is why you can rely on a Mitsubishi automation solution – because we know first hand about the need for reliable, efficient, easy-to-use automation and control in our own factories.

The Mitsubishi brand name is recognized around the world as a symbol of premium quality.

Mitsubishi Electric Corporation is active in space development, transportation, semiconductors, energy systems, communications and information processing, audio visual equipment, home electronics, building and energy management and automation systems, and has 237 factories and laboratories worldwide in over 121 countries.

As one of the world’s leading companies with a global turnover of over 4 trillion

Yen (over $40 billion), employing over

100,000 people, Mitsubishi Electric has the resource and the commitment to deliver the ultimate in service and support as well as the best products.

Global Partner.

Local Friend.

EUROPEAN BRANCHES

MITSUBISHI ELECTRIC EUROPE B.V.

GERMANY

Gothaer Straße 8

D-40880 Ratingen

Phone: +49 (0)2102 / 486-0

MITSUBISHI ELECTRIC EUROPE B.V.

CZECH REPUBLIC

Radlická 714/113a

CZ-158 00 Praha 5

Phone: +420 - 251 551 470

MITSUBISHI ELECTRIC EUROPE B.V.

25, Boulevard des Bouvets

F-92741 Nanterre Cedex

Phone: +33 (0)1 / 55 68 55 68

FRANCE

MITSUBISHI ELECTRIC EUROPE B.V.

Viale Colleoni 7

I-20041 Agrate Brianza (MB)

Phone: +39 039 / 60 53 1

ITALY

MITSUBISHI ELECTRIC EUROPE B.V.

Krakowska 50

PL-32-083 Balice

Phone: +48 (0)12 / 630 47 00

POLAND

MITSUBISHI ELECTRIC EUROPE B.V.

SPAIN

Carretera de Rubí 76-80

E-08190 Sant Cugat del Vallés (Barcelona)

Phone: 902 131121 // +34 935653131

MITSUBISHI ELECTRIC EUROPE B.V.

Travellers Lane

UK-Hatfield, Herts. AL10 8XB

Phone: +44 (0)1707 / 27 61 00

UK

EUROPEAN REPRESENTATIVES

GEVA

Wiener Straße 89

AT-2500 Baden

AUSTRIA

Phone: +43 (0)2252 / 85 55 20

TEHNIKON BELARUS

Oktyabrskaya 16/5, Off. 703-711

BY-220030 Minsk

Phone: +375 (0)17 / 210 46 26

AutoCont C.S. s.r.o.

CZECH REPUBLIC

Technologická 374/6

CZ-708 00 Ostrava-Pustkovec

Phone: +420 595 691 150

KAZPROMAUTOM. Ltd.

KAZAKHSTAN

Mustafina Str. 7/2

KAZ-470046 Karaganda

Phone: +7 7212 / 50 11 50

B:ELECTRIC, s.r.o.

CZECH REPUBLIC

Mladoboleslavská 812

CZ-197 00 Praha 19 - Kbely

Phone: +420 286 850 848

Beijer Electronics SIA

Ritausmas iela 23

LV-1058 Riga

Phone: +371 (0)784 / 2280

LATVIA

Beijer Electronics AS

Postboks 487

NO-3002 Drammen

Phone: +47 (0)32 / 24 30 00

NORWAY

Sirius Trading & Services ROMANIA

Aleea Lacul Morii Nr. 3

RO-060841 Bucuresti, Sector 6

Phone: +40 (0)21 / 430 40 06

Beijer Electronics AB

Box 426

SE-20124 Malmö

Phone: +46 (0)40 / 35 86 00

SWEDEN

Omni Ray AG

Im Schörli 5

CH-8600 Dübendorf

SWITZERLAND

Phone: +41 (0)44 / 802 28 80

TEXEL ELECTRONICS Ltd.

2 Ha´umanut, P.O.B. 6272

IL-42160 Netanya

Phone: +972 (0)9 / 863 39 80

ISRAEL

CEG INTERNATIONAL LEBANON

Cebaco Center/Block A Autostrade DORA

Lebanon - Beirut

Phone: +961 (0)1 / 240 430

ESCO D & A

Culliganlaan 3

BE-1831 Diegem

Phone: +32 (0)2 / 717 64 30

BELGIUM Beijer Electronics A/S

Lykkegårdsvej 17

DENMARK

DK-4000 Roskilde

Phone: +45 (0)46/ 75 76 66

Beijer Electronics UAB LITHUANIA

Savanoriu Pr. 187

LT-02300 Vilnius

Phone: +370 (0)5 / 232 3101

Craft Con. & Engineering d.o.o.

SERBIA

Bulevar Svetog Cara Konstantina 80-86

SER-18106 Nis

Phone: +381 (0)18 / 292-24-4/5

GTS TURKEY

Bayraktar Bulvari Nutuk Sok. No:5

TR-34775 Yukarı İSTANBUL

Phone: +90 (0)216 526 39 90

CBI Ltd.

Private Bag 2016

SOUTH AFRICA

ZA-1600 Isando

Phone: + 27 (0)11 / 977 0770

Koning & Hartman b.v.

BELGIUM

Woluwelaan 31

BE-1800 Vilvoorde

Phone: +32 (0)2 / 257 02 40

Beijer Electronics Eesti OÜ ESTONIA

Pärnu mnt.160i

EE-11317 Tallinn

Phone: +372 (0)6 / 51 81 40

ALFATRADE Ltd.

99, Paola Hill

Malta- Paola PLA 1702

Phone: +356 (0)21 / 697 816

MALTA INEA SR d.o.o.

Izletnicka 10

SER-113000 Smederevo

Phone: +381 (0)26 / 617 163

SERBIA CSC Automation Ltd.

4-B, M. Raskovoyi St.

UKRAINE

UA-02660 Kiev

Phone: +380 (0)44 / 494 33 55

INEA BH d.o.o.

BOSNIA AND HERZEG.

Aleja Lipa 56

BA-71000 Sarajevo

Phone: +387 (0)33 / 921 164

Beijer Electronics OY

Peltoie 37

FIN-28400 Ulvila

FINLAND

Phone: +358 (0)207 / 463 540

INTEHSIS srl bld. Traian 23/1

MD-2060 Kishinev

MOLDOVA

Phone: +373 (0)22 / 66 4242

AutoCont Control s.r.o.

SLOVAKIA

Radlinského 47

SK-02601 Dolny Kubin

Phone: +421 (0)43 / 5868210

AKHNATON BULGARIA

4 Andrej Ljapchev Blvd. Pb 21

BG-1756 Sofia

Phone: +359 (0)2 / 817 6004

UTECO A.B.E.E.

5, Mavrogenous Str.

GR-18542 Piraeus

Phone: +30 211 / 1206 900

GREECE HIFLEX AUTOM. B.V.

NETHERLANDS

Wolweverstraat 22

NL-2984 CD Ridderkerk

Phone: +31 (0)180 – 46 60 04

CS MTrade Slovensko, s.r.o.

SLOVAKIA

Vajanskeho 58

SK-92101 Piestany

Phone: +421 (0)33 / 7742 760

INEA CR d.o.o.

Losinjska 4 a

HR-10000 Zagreb

CROATIA

Phone: +385 (0)1 / 36 940 - 01/ -02/ -03

MELTRADE Ltd.

Fertő utca 14.

HU-1107 Budapest

Phone: +36 (0)1 / 431-9726

HUNGARY Koning & Hartman b.v.

NETHERLANDS

Haarlerbergweg 21-23

NL-1101 CH Amsterdam

Phone: +31 (0)20 / 587 76 00

INEA d.o.o.

Stegne 11

SI-1000 Ljubljana

SLOVENIA

Phone: +386 (0)1 / 513 8100

Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Gothaer Straße 8 /// D-40880 Ratingen /// Germany

Tel.: +49(0)2102 4860 /// Fax: +49(0)2102 4861120 /// [email protected] /// www.mitsubishi-automation.com

Specifications subject to change /// Art.-no. 167840-F /// 10.2010

All trademarks and copyrights acknowledged.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents