output shouldn’t be active more than 120s. Beyond enable add/remove mode on main controller, Group 2: multilevel sensor report (triggered at change of stop the movement. this time overheating protection can be activated (in press service button S for more than 6 second or temperature sensor) up to 16 nodes. Keeping pressed push-button (>2s) connected to I1 (up), this case outputs will switch off for 60s). press push button I1 five times within 3s (5 times Automatic calibration initiates up movement, until push-button is released. Package contents change switch state within 3 seconds) in the first 60 Automatic calibration is a process during which the Flush Keeping pressed push-button (>2s) connected to I2 seconds after the module is connected to the power shutter DC learns the position of the limit switches. (down), initiates down movement, until push-button is supply. Shutter positioning calibration released. By this function all parameters of the module are set to (par. 71 set to 0) Manual operation for venetian blinds default values and own ID is deleted. There are two procedures of calibration. (par. 71 set to 1) If service button S is pressed more than 2 and less than 6 Calibration through main controller UI Slates on start position - 0 degree second module is excluded, but configuration parameters 1) Include the module into the Z-wave network, Clicking push-button (for time < full turn slates time-par.72) according to module include instructions. connected to I1 (up), initiates slates turning towards end - Set the parameter 78 (Forced Flush shutter DC 180 degree position, until push-button is released. calibration) value to 1. Clicking push-button (for time < full turn slates time-par.72) Flush shutter DC performs the calibration process, connected to I2 (down), initiates shutter down movement. completing full cycle - up, down and up again. If the shutter is moving, each click, of any push-button, will Set the parameter 78 (Forced Flush shutter DC stop the movement. calibration) value to 0. Keeping pressed push-button (for time > full turn slates Qubino Flush shutter DC Electrical diagram 12 - 24VDC The INNOVATIVE and SMALLEST Flush shutter DC are not set to default values. Associations ORDERING CODE Z-WAVE FREQUENCY ZMNHOD1 2) Association enables Flush shutter DC module to transfer commands inside Z-wave network directly (without main 868,4 MHz 3) controller) to other Z-Wave modules. ZMNHOD2 921,4 MHz ZMNHOD3 908,4 MHz ZMNHOD4 869,0 MHz Associated Groups: 4) Root device: Notes for the diagram: Group 1: default reporting group (reserved for the main Calibration through the inputs I1 and I2 time-par.72) connected to I1 (up), initiates full slates turn controller). 1) and up movement, until the push-button is released. Group 2: basic on/off (triggered at change of the input I1 according to module inclusion instructions. Keeping pressed push-button (for time > full turn slates state and reflecting its state) up to 16 nodes. 2) time-par.72) connected to I2 (down), initiates shutter down Group 3: basic on/off (triggered at change of the input I2 input and wait until the shutter reach upper limit switch. movement, until the push-button is released. state and reflecting its state) up to 16 nodes. 3) Keeping pressed push-button (for time > (full turn slates Group 4: basic on/off (triggered at sensing moving input and wait until the shutter reach lower limit switch. time +2s)) connected to I1 (up), initiates up movement, direction of roller: up=FF, down=0) up to 16 nodes. 4) until push-button is released. Include the module into the wireless network, + +VDC (12 – 24VDC) This Z-Wave module is used to control the motor of blinds, - -VDC (0V) rollers, shades, venetian blinds, etc.. The module can be Q1 Output for motor UP (open) controlled either through a Z-Wave network or through the Q2 Output for motor DOWN (close) wall switch. I2 Input for switch/push button DOWN (close) Precise positioning is supported for motors equipped with I1 Input for switch/push button UP (open) mechanical or electronic end switches. The module is TS Terminal for digital temperature sensor (only Group 5: basic on/off (triggered at reaching roller position: input and wait until the shutter reach upper limit switch. Slates on end position - 180 degree designed to be mounted inside a “flush mounting box”, for Flush shutter DC module compatible digital bottom=FF, top=0) up to 16 nodes. Slates tilting position calibration Clicking push-button (for time < full turn slates time-par.72) hidden behind a traditional wall switch. Module measures temperature sensor, which must be ordered Group 6: basic on/off (triggered at reaching roller position: (par. 71 set to 1) connected to I1 (up), initiates shutter up movement. power consumption of motor and support connection of separately). bottom=FF, not bottom=0) up to 16 nodes. When enabling venetian blind mode, position calibration Clicking push-button (for time < full turn slates time-par.72) Group 7: multilevel set (triggered at changes of value of for slats titling must be done. After doing this, position and connected to I2 (down), initiates slates turning towards Service button (used to the Flush shutter DC position) up to 16 nodes. angle of slates can be set. By default full turn time for start - 0 degree position, until the push-button is released. add or remove module Group 8: multilevel set (triggered at changes of value of slates is set to 1,5s. This value can be changed with If the shutter is moving, each click, of any push-button, will from slats tilting position) up to 16 nodes. parameter 72. stop the movement. Group 9: multilevel sensor report (triggered at change of 1) Include and make module calibration according to Keeping pressed push-button (for time > full turn slates section ‘Shutter positioning calibration’. time-par.72) connected to I1 (up), initiates shutter up ZMNHOD5 916,0 MHz digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. S Supported switches Module supports mono-stable switches (push button) and bi-stable switches. the Z-Wave network). Installation temperature sensor) up to 16 nodes. Before the installation disconnect power supply. Module Inclusion (Adding to Z-wave network) Connect the module according to electrical diagram. Locate the antenna far from metal elements (as far as possible). Do not shorten the antenna. Quick press the switch/push-button connected to I1 Quick press the switch/push-button connected to I2 Quick press the switch/push-button connected to I1 End point 1: 2) Set parameter 71 to 1 ‘Venetian blinds’. movement, until the push-button is released. Connect module to power supply (with Group 1: Lifeline group, 0 nodes allowed. 3) Exclude the module (without reset!). Keeping pressed push-button (for time > full turn slates temperature sensor connected - if purchased), Group 2: basic on/off (triggered at change of the input I1 4) Include the module. time-par.72) connected to I2 (down), initiates full slates auto-inclusion (works for about 5 seconds after state and reflecting its state) up to 16 nodes. 5) After module inclusion beside main shutter widget, turn and down movement, until the push-button is connected to power supply) or Group 3: basic on/off (triggered at change of the input I2 another widget for slates control will appear on UI. released. By default full turn movement is set to 1,5s. If this time Keeping pressed push-button (for time > (full turn slates Danger of electrocution! press service button S for more than 2 second or state and reflecting its state) up to 16 nodes. press push button I1 three times within 3s (3 times Group 4: basic on/off (triggered at sensing moving is too long (if after slates full cycle shutter starts time +2s)) connected to I2 (down), initiates down change switch state within 3 seconds). direction of roller: up=FF, down=0) up to 16 nodes. moving up or down), decrease this time defined with movement, until push-button is released. Module installation requires a great degree of skill and may be performed only by a qualified and licensed 6) electrician. NOTE1: For auto-inclusion procedure, first set main Group 5: basic on/off (triggered at reaching roller position: parameter 72. If this time is to short (if slats will not Configuration parameters Even when the module is turned off, voltage may be controller into inclusion mode and then connect module to bottom=FF, top=0) up to 16 nodes. turn for full cycle), increase this time defined with Parameter no. 10 - Activate/deactivate functions ALL present on its terminals. Any works on configuration power supply. Group 6: basic on/off (triggered at reaching roller position: parameter 72. ON / ALL OFF changes related to connection mode or load must be NOTE2: When connecting temperature sensor to module bottom=FF, not bottom=0) up to 16 nodes. Manual operation for shutter Available config. parameters (data type is 2 Byte DEC): always performed by disconnected power supply that has already been included, you have to exclude Group 7: multilevel set (triggered at changes of value of (par. 71 set to 0) default value 255 (disable the fuse). module first. Switch off power supply, connect the sensor the Flush shutter DC position) up to 16 nodes. Module allows connecting of push-buttons (mono-stable) 255 - ALL ON active, ALL OFF active. Note! and re-include the module. End point 2: or switches (bi-stable) to I1 and I2 terminals. 0 - ALL ON is not active, ALL OFF is not active Group 1: Lifeline group, 0 nodes allowed. Clicking push-button (<2s) connected to I1 (up), initiates 1 - ALL ON is not active ALL OFF active recommended values. Connect the module only in Module Exclusion/Reset Z-Wave network) up movement. 2 - ALL ON active ALL OFF is not active accordance to the Group 2: multilevel set (triggered at changes of value of Connect module to power supply slats tilting position) up to 16 nodes. Clicking push-button (<2s) connected to I2 (down), Module responds to commands ALL ON / ALL OFF that bring module within maximum 1 meter (3 feet) of the End point 3: initiates down movement. may be sent by the main controller or by other controller main controller, Group 1: Lifeline group, 0 nodes allowed. If the shutter is moving, each click, of any push-button, will belonging to the system. Do not connect the module to loads exceeding below diagrams. Improper connections may be dangerous. When device is loaded with max. rated current 2A, (Removing from This parameter defines shutter motor moving time of configuration parameters (data type is 1 Byte DEC): Parameter no. 40 - Power reporting in Watts on power complete opening or complete closing. default value 8 = 800ms change for Q1 or Q2 configuration parameters (data type is 2 Byte DEC): 3 – 50 = 0,3seconds – 5seconds (100ms resolution) Set value means percentage, set value from 0 – 100 = 0% default value 0 Parameter no. 86 – Power consumption at limit switch Dimensions (WxHxD) 41,8x36,8x15,4mm COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V7 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 - 100%. Available configuration parameters (data type is 1 0 – moving time disabled (working with limit delay time (package) (79x52x22) NOTE: The above list is valid for the product with a switches) This parameter defines the max time at limit switch, when Weight (Brutto with package) 28g (34g) temperature sensor connected to TS terminal at the time 1 – 32767 = 0,1seconds – 3276,7seconds. After that power consumption is below power threshold. If the power For installation in boxes Ø ≥ 60mm or 2M of inclusion. In case the sensor is not connected then the time motor is stopped (relay goes to off state) consumption during this time is below power threshold Switching H bridge following command class and endpoint 3 are not Byte DEC): Available default value 1 0 – reporting disabled 1 – 100 = 1% - 100% Reporting enabled. Power NOTE: Important is that the reference position to manually (par. 76), the active output will switch off, means that limit report is send (push) only when actual power (in set moving time is always shutter lower position! switch is reached. Available configuration parameters Watts) in real time changes for more than set Set parameter 74 to 0 and move the shutter (using (data type is 1 Byte DEC): percentage comparing to previous actual power in up/down push buttons or main controller UI) to the lowest default value 8 = 800ms Watts, step is 1%. desired position. On this shutter position, set parameter 74 3 – 50 = 0,3seconds – 5seconds (100ms resolution) NOTE: if power changed is less than 1W, the report is not to time for complete opening or complete closing. At this Parameter no. 90 – Time delay for next motor send (pushed), independent of percentage set. point shutter can be moved up (open) for set time, but movement Parameter no. 42 – Power reporting in Watts by time can't be moved down because this position is already set This parameter defines the minimum time delay between interval for Q1 or Q2 as lower shutter position. next motor movement (minimum time between switching Set value means time interval (0 – 32767) in seconds, To change shutter lower position below already set motor when power report is send. Available configuration (manual recalibration), parameter 74 must be set to 0 and parameters (data type is 1 Byte DEC): parameters (data type is 2 Byte DEC): repeat the procedure described above. default value 5 = 500ms default value 300 = 300s In case shutter has limit switches, but anyhow you would 1 – 30 = 0,1seconds – 3seconds (100ms resolution) 0 – Reporting Disabled like to limit opening/closing position by time, you can still Parameter no. 110 – Temperature sensor offset 1 – 32767 = 1 second – 32767 seconds. Reporting do it. In case you put time that is longer that settings enabled, power report is send with time interval set opening/closing real time limited by limit switches, shutter Set value is added or subtracted to actual measured value by entered value. will stop at limit switch, but the module relay will switch off by sensor. Parameter no. 71 – Operating modes after define time, not by shutter limit switch. Take in is 2 Byte DEC): This parameter defines selection between two available consideration that in this condition, the positioning with default value 32536 operating modes. Available configuration parameters slider through UI will not show correct shutter position. 32536 – offset is 0.0C (data type is 1 Byte DEC): Parameter no. 76 - Motor operation detection From 1 to 100 – value from 0.1 °C to 10.0 °C is default value 0 Power threshold to be interpreted when motor reach the 0 – Shutter mode limit switch. Available configuration parameters (data type 1 – Venetian mode (up/down and slate rotation) is 1 Byte DEC): and on again). Available configuration Available configuration parameters (data type From 1001 to 1100 – value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature. NOTE: When setting parameter, module needs to be default value 6 = 0,6W Parameter no. 120 – Digital temperature sensor excluded and included again! Please check detailed Available settings: 5 - 100 (0,5W - 10W), step is reporting 0,1W. If digital temperature sensor is connected, module reports description in this manual. Parameter no. 72 – Slats tilting full turn time NOTE: Motors with power consumption less than 0,5W measured temperature on temperature change defined by This parameter defines the time necessary for slats to could not be auto calibrated. In that case set time this parameter. Available configuration parameters (data make full turn (180 degrees). Available configuration manually (par. 74). type is 1 Byte DEC): parameters (data type is 2 Byte DEC): Parameter no. 78 - Forced Shutter DC calibration Default value 5 = 0,5°C default value 150 = 1,5 seconds By modifying the parameters setting from 0 to 1 a Shutter 0 – Reporting disabled 0 – Tilting time disabled DC module enters the calibration mode. Available 1-127 = 0,1°C – 12,7°C, step is 0,1°C 1 – 32767 = 0,01seconds – 327,67 seconds configuration parameters (data type is 1 Byte DEC): NOTE: If time set is too high, this will result that after full default value 0 turn, shutter will start move up/down, for time remaining. 1 - Start calibration process (when calibration Power supply 12-24VDC +/-10% Parameter no. 73 – Slats position process is finished, completing full cycle - up, down Rated load current 2A This parameter defines slats position after up/down and up, set the parameter 78 (Forced Shutter Overcorrect protection 5A movement through Z-wave or push-buttons. Available calibration) value back to 0. Output circuit power of DC 48W (24VDC) Technical Specifications configuration parameters (data type is 1 Byte DEC): Parameter no. 85 – Power consumption max delay output (resistive load) default value 1 time Power measurement 0 - Slats return to previously set position only in case This parameter defines the max time before motor power accuracy of Z-wave control (not valid for limit switch positions). consumption is read after one of the relays is switched Digital temperature sensor 1 - Slats return to previously set position in case of ON. If there is no power consumption during this max range (sensor must be Z-wave control, push-button operation or when the time (motor not connected, damaged or requires higher ordered separately) lower limit switch is reached. time to start, motor in end position,...) the relay will switch Parameter no. 74 – Motor moving up/down time OFF. Time is defined by entering it manually. Available materials) supported: Z-Wave Device Class: BASIC_TYPE_ROUTING_SLAVE GENERIC_TYPE_SWITCH_MULTILEVEL SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL Z-Wave Supported Command Classes: COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 COMMAND_CLASS_POWERLEVEL_V1 COMMAND_CLASS_BASIC_V1 COMMAND_CLASS_SWITCH_ALL_V1 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_METER_V4 COMMAND_CLASS_SENSOR_MULTILEVEL_V7 COMMAND_CLASS_MULTI_CHANNEL_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_CONFIGURATION_V1 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC_V1 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Endpoint1: Device Class: added to actual measured temperature. up to 30 m indoors (depending on building off Distance +/-5% -50 ~ +125°C COMMAND_CLASS_SENSOR_MULTILEVEL_V7 Endpoint 2 is supported by the module only when the parameter no. 71 is set to the value 1 and the module is excluded and re-included into the network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. All constantly powered nodes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network. Important disclaimer Z-wave wireless communication is inherently not always 100% reliable, and as such, this product should not be used in situations in which life and/or valuables are solely dependent on its function. Warning! Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding BASIC_TYPE_ROUTING_SLAVE GENERIC_TYPE_SWITCH_MULTILEVEL SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL the collection systems available. If electrical appliances Command Classes: COMMAND_CLASS_ZWAVEPLUS_INFO_V2 substances can leak into the groundwater and get into the COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_BASIC_V1 COMMAND_CLASS_SWITCH_ALL_V1 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_METER_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC_V1 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Endpoint2: Device Class: are disposed of in landfills or dumps, hazardous food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. This user manual is subject to change and improvement without notice. NOTE: User manual is valid for module with SW version S3 (SW version is part of P/N)! Example: P/N: ZMNHODx H1S3P1 BASIC_TYPE_ROUTING_SLAVE GENERIC_TYPE_SWITCH_MULTILEVEL SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL Qubino Command Classes: Goap d.o.o. Nova Gorica COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_BASIC_V1 COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC_V1 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Ulica Klementa Juga 007 Endpoint 3: Device Class: Operation temperature -10 ~ +40°C GENERIC_TYPE_SENSOR_MULTILEVEL SPECIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL Electricity consumption cca. 0,3W Command Classes: 5250 Solkan Slovenia E-mail: [email protected] Tel: +386 5 335 95 00 Web: www.qubino.com Date: 15.10.2015 Document: Qubino_Flush shutter DC PLUS user manual_V1.2_eng
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project