IPM-4SE

4-Port E1 IP Multiplexer

LEGAL

The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union Technologies assumes no responsibility, however, for possible errors or omissions, or for any consequences resulting from the use of the information contained herein. CTC Union

Technologies reserves the right to make changes in its products or product specifications with the intent to improve function or design at any time and without notice and is not required to update this documentation to reflect such changes.

CTC Union Technologies makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does CTC Union assume any liability arising out of the application or use of any product and specifically disclaims any and all liability, including without limitation any consequential or incidental damages.

CTC Union products are not designed, intended, or authorized for use in systems or applications intended to support or sustain life, or for any other application in which the failure of the product could create a situation where personal injury or death may occur. Should the Buyer purchase or use a CTC Union product for any such unintended or unauthorized application, the Buyer shall indemnify and hold CTC Union Technologies and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, expenses, and reasonable attorney fees arising out of, either directly or indirectly, any claim of personal injury or death that may be associated with such unintended or unauthorized use, even if such claim alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product.

TRADEMARKS

Microsoft is a registered trademark of Microsoft Corp.

HyperTerminal™ is a registered trademark of Hilgraeve Inc.

FCC WARNING:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference in which case the user will be required to correct the interference at his own expense. NOTICE: (1) The changes or modifications not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. (2) Shielded interface cables and AC power cord, if any, must be used in order to comply with the emission limits.

CISPR PUB.22 Class A COMPLIANCE:

This device complies with EMC directive of the European Community and meets or exceeds the following technical standard. EN 55022 - Limits and Methods of Measurement of Radio Interference Characteristics of

Information Technology Equipment. This device complies with CISPR Class A.

WARNING:

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

CE NOTICE

Marking by the symbol CE indicates compliance of this equipment to the EMC and LVD directives of the

European Community. Such marking is indicative that this equipment meets or exceeds the following technical standards: EN 55022:1994/A1:1995/A2:1997 Class A and EN61000-3-2:1995, EN61000-3-3:1995 and EN50082-1:1997

CTC Union Technologies Co., Ltd.

Far Eastern Vienna Technology Center (Neihu Technology Park)

8F, No. 60, Zhouzi St.

Neihu, Taipei, 114

Taiwan

Phone: +886-2-2659-1021

FAX: +886-2-2799-1355

IPM-4SE

4-Port E1 IP Multiplexer (TDM over IP)

User Manual

Version 0.9c March 16, 2011

Version 1.0 September 28, 2011 (Updated and released as 1.0)

This manual supports the following models:

IPM-4SE AC

IPM-4SE DC

This document is the current official release manual. Please check CTC Union's website for any updated manual or contact us by E-mail at [email protected]. Please address any comments for improving this manual or to point out omissions or errors to [email protected]. For technical support for this product or other

CTC Union products, contact our support staff at [email protected]. Thank you.

©2010-2011 CTC Union Technologies Co.,Ltd.

All Rights Reserved

The contents of this document are subject to change without any prior notice.

Table of Contents

CHAPTER 1. INTRODUCTION ...................................................................................................................7

 

1.1

W ELCOME .................................................................................................................................................7

 

1.2

P RODUCT D ESCRIPTION ............................................................................................................................7

 

1.3

F EATURES ..................................................................................................................................................7

 

1.4

P HYSICAL A PPEARANCE ...........................................................................................................................8

 

1.5

IPM-4SE A PPLICATION .............................................................................................................................8

 

1.6

IPM-4SE S PECIFICATIONS ........................................................................................................................8

 

CHAPTER 2. INSTALLATION...................................................................................................................10

 

2.1

I NTRODUCTION ........................................................................................................................................10

 

2.2

U NPACKING .............................................................................................................................................10

 

2.3

S ITE P REPARATION .................................................................................................................................10

 

2.4

M ECHANICAL A SSEMBLY ......................................................................................................................10

 

2.5

E LECTRICAL I NSTALLATION ..................................................................................................................11

 

2.6

R ACK I NSTALLATION .............................................................................................................................11

 

2.7

B ASIC C ONFIGURATION AND D IAGNOSIS ...............................................................................................12

 

2.7.1 Utilize tools for diagnosis ................................................................................................................12

 

2.7.2 Basic Troubleshooting .....................................................................................................................12

 

2.8

LED I NDICATORS ....................................................................................................................................12

 

CHAPTER 3. CONFIGURATION AND OPERATION............................................................................13

 

3.1

D ESCRIPTION ...........................................................................................................................................13

 

3.2

F RONT P ANEL I NTRODUCTION ................................................................................................................13

 

3.2.1 System Indicators .............................................................................................................................13

 

3.2.2 Reset Button .....................................................................................................................................13

 

3.2.3 LAN & MNT Ethernet Connectors and Indicators...........................................................................13

 

3.2.4 Alarm LED Display..........................................................................................................................13

 

3.2.5 RS232 Connector .............................................................................................................................13

 

3.2.6 MNT Port (10/100M Ethernet Port for Telnet, or SNMP-based Management)...............................13

 

3.3

R EAR P ANEL I NTRODUCTION ..................................................................................................................14

 

3.3.1 WAN Interface: ................................................................................................................................14

 

3.3.2 AC Power Socket and Switch (On/Off switch for AC): ....................................................................14

 

3.3.3 DC Power Socket and Switch (On/Off switch for DC): ...................................................................14

 

3.4

L OOPBACK M ODE ...................................................................................................................................14

 

3.5

IP C ONFIGURATION .................................................................................................................................14

 

3.6

I NTERFACE C ONFIGURATION ..................................................................................................................14

 

3.7

F AULT R EPORT ........................................................................................................................................15

 

3.8

S AVE C ONFIGURATION ...........................................................................................................................15

 

3.9

C OMMAND L INE I NTERFACE S ETUP ........................................................................................................15

 

3.9.1 Using HyperTerminal™ as Local Console Terminal ......................................................................15

 

3.9.2 Telnet in for Remote Console Terminal ...........................................................................................15

 

3.10

F ACTORY D EFAULT S CRIPTS ................................................................................................................18

 

3.10.1 Determine Device MAC Address ...................................................................................................18

 

3.10.2 CO Unit Factory Default Script .....................................................................................................18

 

3.10.3 CPE Unit Factory Default Script ...................................................................................................19

 

3.11

A PPLICATION E XAMPLES ......................................................................................................................20

 

3.11.1 Point-to-Point with single E1 (port1) and LAN port active. ..........................................................20

 

3.11.2 Point-to-Point with Single E1 (port 1), Fractional /w CRC4 (nx64, n=8) active. .........................20

 

3.11.3 Notes on Fractional E1 Operation.................................................................................................21

 

3.11.4 Using the IPM in a Routing Environment ......................................................................................22

 

APPENDIX .....................................................................................................................................................23

 

A BBREVIATIONS ...........................................................................................................................................23

 

i

Table of Contents ii

Chapter 1 Introduction

Chapter 1. Introduction

1.1 Welcome

In telecommunications, TDM over IP (TDMoIP) is the emulation of time-division multiplexing (TDM) over a packet switched network (PSN). In the case of the IPM-4SE, TDM refers to E1 signals, while the PSN is based on Ethernet.

TDM over IP is a type of pseudo wire (PW). However, unlike other traffic types that can be carried over pseudo wires (e.g. ATM, Frame Relay, and Ethernet), TDM is a real-time bit stream, leading to TDM over

IP having unique characteristics. In addition, conventional TDM networks have numerous special features, in particular those required in order to carry voice-grade telephony channels. These features imply signaling systems that support a wide range of telephony features, a rich standardization literature, and well-developed

Operations and Management (OAM) mechanisms.

One critical issue in implementing TDM PWs is clock recovery. In native TDM networks the physical layer carries highly accurate timing information along with the TDM data which is easily recovered using phaselocked loop (PLL) techniques. However, when emulating TDM over PSNs this synchronization is absent.

TDM timing standards can be exacting, and conformance with these may require innovative mechanisms to adaptively reproduce the TDM timing.

Another issue that must be addressed is TDM over IP packet loss concealment (PLC). Since TDM data is delivered at a constant rate over a dedicated channel, the native Ethernet network may have bit errors. All

PSNs suffer to some degree from packet loss, and this must be compensated when delivering TDM over a

PSN.

1.2 Product Description

The IPM-4SE series is a "Multi-service (TDM and Ethernet) Over LAN/MAN" bridge, which transports one, two, three, or four ports of ITU-T G.703 E1 and one LAN into Ethernet packets. Its target application shown in Figure 1.2 is the transparent E1 port interconnection via the Ethernet network (using Ethernet packets).

Based upon RFC3916, the IPM-4SE series employs the latest Circuit Emulation System over packet technology.

The E1 over IP of IPM-4SE is compliant with IETF “CES over IP” standard. Versatile LEDs are provided for alarms and status indication.

1.3 Features

• Supports E1 (only) over 100M Ethernet to LAN/MAN.

• Provide one LAN for Ethernet access.

• User side provides standard PDH (E1 only) interfaces using balanced signals for twisted pair.

• Full-duplex 100M Ethernet Interface.

• Provides auto-negotiation which can auto configure 10/100M depending on the speed of LAN/MAN port.

• Supports "E1" Timing, i.e. LAN/MAN bandwidth requires at leased 5MHz or 10MHz.

• Provides "ACT" and "ALM" LED indicators for each PDH interface.

• Provides "Link status, Activity" LED indicators for 100M Ethernet interface.

• Stand–alone desktop unit, optional 19" rack mountable.

• Supports AC 100 ~ 240V input and optional DC -36 ~ -75V input for redundancy.

Important: T1(DS1) is currently not supported in this model.

7

Chapter 1 Introduction

1.4 Physical Appearance

Figure 1.1 IPM-4SE 4-Port E1 Physical Appearance

Important: T1(DS1) is currently not supported in this model

1.5 IPM-4SE Application

The IPM-4SE is mainly applied for the solution of wire-line application connecting PSTN via E1 and Router via 100BaseTx and for integrating various equipments based on traditional TDM and popular IP services.

Figure 1.2 IPM-4SE 4-Port E1/T1 Application

1.6 IPM-4SE Specifications

100M Ethernet Interface

• Compliant with 802.3/802.3u standards

• 10/100-BaseT with RJ-45 connector

• Full-duplex

• Supports Auto-Negotiation per IEEE802.3u

• LED indicators for Ethernet: Link status and Activity

PDH Interfaces x 4

E1 Interface

Data Rate: 2.048 Mbit/s

± 50 ppm

Line Code: HDB3

Impedance: 120 ohms

± 5% resistive, balanced.

LED indications for E1: ACT, ALM

Connector Type: RJ-45 per USOC RJ-48C (Rx pair 1&2; Tx pair 4&5)

8

Power Supply

(Optional) DC: -18 ~ -75 V

Power Consumption: less than 10W

Operating Environment

Ambient temperature: 0 ~ 40

°C for indoor application

(Optional): 0 ~ 55

°C

Storage temperature: 0 ~ 85

°C

Relative humidity: 5 ~ 95% non condensing

Physical Dimension

Height: 44.5 mm (1U)

Width: 370 mm

Depth: 215 mm

Weight: 2 Kg (net)

9

Chapter 1 Introduction

Chapter 2 Installation

Chapter 2. Installation

2.1 Introduction

The Installation chapter will cover the physical installation of the IPM-4SE, 4-Port E1 IP Multiplexer, the electrical connections, interface connections and cabling requirements. A brief overview of the functional components such as main unit and management options will also be outlined in this chapter.

Required Tools

You will need these tools to install the IPM-4SE:

Number 2 Phillips screwdriver for the 3mm and the 12-24 rack installation screws.

Wrist strap or other personal grounding device to prevent ESD occurrences.

Antistatic mat or antistatic foam to set the equipment on.

2.2 Unpacking

If there is a possibility for future relocation of the IPM-4SE unit, please keep the packing cartons and protection packaging materials. Carefully unpack and inspect the unit and accessories for potentially damaged or missing parts. Contact our nearest sales representative or our company directly if you detect any damaged or missing parts. Improper handling during shipment may cause early failure. Notify the shipper or forwarder immediately if the outer package shows signs of dropping or rough handling.

2.3 Site Preparation

Install the IPM-4SE within reach of an easily accessible grounded AC outlet or three wire (-48VDC, Power return, Earth Ground) central office power. The AC outlet should be capable of furnishing 90 to 250 VAC.

Refer to 2.4 Electrical Installation. Allow at least 10cm (4 inch) clearance at the front of the IPM-4SE for the

E1 and LAN copper cables.

2.4 Mechanical Assembly

The IPM-4SE is designed for desktop, shelf or rack mount installation and will require 1U space in a standard EIA 19" rack. The IPM-4SE chassis is delivered completely assembled upon delivery. The rack mount adapters may be placed along the front of the chassis as shown below.

Figure 2.1 Standard 19" Rack-Mount Installation of IPM-4SE Unit requires 1RU space

10

Chapter 2 Installation

2.5 Electrical Installation

With an AC power model, AC power is supplied to the IPM-4SE through a standard IEC C14 3-prong receptacle, located on the rear of the unit. Any national power cord with IEC C13 line plug may be used to connect AC power to the power module. With a DC model, DC -48V is connected to the terminal block located on the rear of the module, observing the proper polarity. The IPM-4SE should always be grounded through the protective earth lead of the power cable in AC installations, or via the frame ground connection for DC installations.

DC IN

-V FG +V

36~75VDC

Left: Live line

Right: Neutral l ine

Midd le: Ground

Left: -V (-48V)

Right: +V (0V)

Middle: Frame Ground

IEC C13 line plug

Figure 2.2 IEC (AC) & terminal block (DC) power connector pin assignment

2.6 Rack Installation

There are 3 common parts for each IPM-4SE package, including 1 set of TDM over IP multiplexer, 1 AC power cord. If the IPM-4SE is intended for mounting into a rack, a pair of L-type Steel brackets with 16 screws should be requested with the user's order. The user manual, an electronic PDF format file, will be included on a CD-ROM along with any accessory files such as SNMP MIB files and example script files.

The following Figure 2.3 shows desktop or shelf operation and Figure 2.4 shows rack mounting of the IPM-

4SE.

Figure 2.3 Stand-alone shelf or tabletop use h

Rack Brackets

Figure 2.4 Rack mounted use

11

Chapter 2 Installation

2.7 Basic Configuration and Diagnosis

The IPM-4SE units are shipped in pre-configured pairs. One is labeled CO (central office) and the other labeled CPE (customer premises equipment). Simply place the CO unit towards the E1 clock source (SDH multiplexer, BSC, carrier, etc.) and place the CPE unit connecting to the E1 recovery equipment (DSU/CSU,

BTS, customer, etc.). After installing the device and powering on, if E1 transmission does not immediately work, follow the diagnostics and basic troubleshooting.

2.7.1 Utilize tools for diagnosis

• Maintain and troubleshoot the status from LED indications, shown below.

• Connect basic VT100 terminal to console port using 115.2K, 8bit, no parity, 1 stop bit no flow control

• Telnet NE using port 8888 to show the alarm or status if association still works.

• Associate NE via IPM-4SE GUI (tbd) to diagnose if configuration is correct and what status occurs.

2.7.2 Basic Troubleshooting

• If a ping of the remote NE via LAN/MAN does not respond, then please check the LAN connections and make sure Switch/LAN/MAN are working.

• If TDM or LAN provides unstable quality of service, please check the link performance or access port

(E1/LAN) and reset the NE.

2.8 LED Indicators

LED Name

PWR

ALM

Light Status

Green

Red

Descriptions

Power is on

Raised from any PDH link alarms

Table 2.1 Chassis LED Indications of IPM-4SE

LED Name

ACT

ALM

Light Status

Green

Yellow

Descriptions

E1 traffic is active (Ports 1~4)

Raised from E1 link alarms (Ports 1~4)

Table 2.2 E1 LED Indications of IPM-4SE

LED Name

Ethernet LINK

Ethernet ACT

Light Status

Green

Blinking Yellow

Descriptions

Ethernet link is up

TX or RX Ethernet traffic is active

Table 2.3 MNT, LAN and WAN (RJ-45) LED Indications of IPM-4SE

12

Chapter 3 Configuration and Operation

Chapter 3. Configuration and Operation

3.1 Description

IPM-4SE consists of the front panel and the rear panel. The views and description of front and rear panels are shown in Figure 3.1 and 3.2.

The IPM-4SE units are shipped in pre-configured pairs. One is labeled CO (central office) and the other labeled CPE (customer premises equipment). Be sure to carefully check the model's sticker. Simply place the CO unit towards the E1 clock source (SDH multiplexer, BSC, carrier, etc.) and place the CPE unit connecting to the E1 recovery equipment (DSU/CSU, BTS, customer, etc.).

3.2 Front Panel Introduction

There are 6 items that need to be mentioned on the front panel of IPM-4SE.

3.2.1 System Indicators

PWR (Power Exist LED) Make sure power is available and switch is turned on

ALM (for any of E1 Links or WAN port Status)

3.2.2 Reset Button

Provides the facility of rebooting the system without powering off.

3.2.3 LAN & MNT Ethernet Connectors and Indicators

The Lan and MNT Ethernet interfaces use an RJ-45 connector with LED indicators

There are green and yellow LED indicators:

• Green Link (Link Up/Down Status)

• Yellow Act (TX/RX Active Status)

3.2.4 Alarm LED Display

E1/T1 Interface

• Green ACT (E1 Port Traffic)

• Yellow ALM (E1 Port Link Status)

The "RED" chassis LED indicates one of the following alarms occurred:

E1/T1 LOS, AIS, L-bit or no received traffic from WAN port

3.2.5 RS232 Connector

An RS232 interface with baud-rate 115200bps via DB9 (female)-to-DB9 (male) cable is provided for diagnostics. The user commands (CLI command) are listed in Table 3.1.

3.2.6 MNT Port (10/100M Ethernet Port for Telnet, or SNMP-based Management)

Provides a user management interface - Telnet or SNMP, via MNT port for managing the local & remote

NEs.

Figure 3.1 IPM-4SE 4-Port E1 Front Panel View

13

Chapter 3 Configuration and Operation

3.3 Rear Panel Introduction

There are three parts to the rear panel of the IPM-4SE, shown in Figure 3.2.

Figure 3.2 IPM-4SE 4-Port E1/T1 Rear Panel View

3.3.1 WAN Interface:

The Ethernet WAN interface is an RJ-45 connector with LED

There are green and yellow LED indicators:

• Green Link (Link Up/Down Status)

• Yellow Act (TX/RX Active Status)

3.3.2 AC Power Socket and Switch (On/Off switch for AC):

The power socket provides the power with an input range of AC 110 ~ 240V via standard IEC connector.

3.3.3 DC Power Socket and Switch (On/Off switch for DC):

The power terminal strip provides the power with an input range of DC -75 ~ -36V

3.4 Loopback Mode

The IPM-4SE provides two types of loopback: "E1 Remote Loopback" and "E1 Local Loopback". (Please refer to Figure 3.4).

Local Loopback Remote Loopback

TDM

IPM-4SE

LAN/MAN

IPM-4SE

TDM

Figure 3.4 IPM-4SE E1 Loopback Mode

3.5 IP Configuration

The IP address, subnet mask address, and Gateway address of the management port (MNT) should be setup thru RS232 console using CLI commands.

3.6 Interface Configuration

For the LAN configuration, the setting of traffic bandwidth is provided to ensure the quality of service in

TDM circuits with 16 throughput options of 50K, 100K, 150K, 200K, 250K, 300K, 350K, 400K, 800K,

1.6M, 3.2M, 6.4M, 12.8M, 25.6M, 51.2M and 100M, depending on the user's requirement. In addition, setting 100M option will utilize all the available bandwidth to LAN with no QoS for E1 traffic.

For the E1 configuration, the LEDs will be lit after enabling the E1 channel and user can select the remote output E1 channel for flexible cross connection purposes. A Jitter Buffer is also used to compensate for the latency of real network traffic between two devices. The Jitter buffer includes 8 options which are 11, 23, 40,

75, 99, 145, 192, and 239 ms.

14

Chapter 3 Configuration and Operation

3.7 Fault Report

The alarms/status of NE node can be reported thru RS232 or Telnet (CLI command). The resource of alarms is only from TDM interface (E1) and the acronym alarm names are shown as follows.

E1LOS: (E1 Loss of Signal) No E1 line connected to the specific E1 port.

E1AIS: (E1 Alarm Indication Signal) AIS (all 1’s) signal input from the specific E1 port.

PWLBIT: (Pseudo Wire L bit) Remote E1 port failure condition (LOS or AIS).

PWRBIT: (Pseudo Wire R bit) Packet loss occurred at remote E1 port.

PWSEQNUMERR: (Pseudo Wire Sequence Number Error) Packet loss occurred for specific E1 local port.

JBUFEMP: (Jitter Buffer Empty) Buffer empty occurred at specific E1 port. (typically from link down or mis-configuration.) If link is good, increase the jitter buffer at the expense of latency.

JBUFOV: (Jitter Buffer Overflow) Buffer overflow occurred at specific E1 port. There is probably a problem with bi-direction throughput of the Ethernet WAN link.

3.8 Save Configuration

After changing the configurations from CLI or Telnet, the "SAVE" action should be done to store the configuration into non-volatile storage. This can avoid loosing settings if the device is rebooted or powered off/on.

3.9 Command Line Interface Setup

3.9.1 Using HyperTerminal™ as Local Console Terminal

When logging into the HyperTerm, set up the terminal port as follows:

• Bit rate: 115200bps

• Data bit: 8

• Parity: none

• Stop bit: 1

• Flow control: none

• Login password: admin (factory default)

3.9.2 Telnet in for Remote Console Terminal

If using the "Telnet" command in an Operation System, such as Windows or Linux, the default port of the

IPM-4SE is 8888 instead of the standard port 23 for security issue. The default IP address of the management port is 192.168.1.1 and net mask is 255.255.255.0. The IP address, therefore, of the Telnet Client needs to be set in the IP range 192.168.1.2 to 192.168.1.254 and the same net mask. An example of a command line in

Windows would be the following:

C:\WINDOWS\system32> telnet 192.168.1.1 8888

The factory default login password in both serial console CLI and Telnet modes is "admin". The CLI user commands are listed in the following table for detail and implemented on CLI and TELNET modes:

3.9.3 Setting CLI (Telnet) login password

Important: DO NOT FORGET the password once changed or you must return the unit to factory. There is no back-door password or any recovery procedure.

CLI> setpass c

===== Set Password for CLI Login =====

Enter Old Password: admin ==> OK!

Enter New Password: *** ==> OK!

Re-Enter New Password: *** ==> OK!

CLI>

15

CLI Command 

System Commands  logout  cdisp  csave  cload  reboot  passwd   setpass mode  ipset ip_addr net_mask gateway_ip  ipget  trapset mode trap_ip_addr  trapget  ntpset mode server_ip_addr  ntpget  upgrade server_ip file_name  backup tftp_server_ip file_name  restore tftp_server_ip file_name  tgmode mode  ceschclkset ch_num clksrc  tgpriset 1st.source 2nd.source  tge1loop e1_num  tgget  timeset hour min sec  dateset year month day  timeget  lpkset ch_no mode enable lpkget ping ip_addr

Chapter 3 Configuration and Operation

CLI Command Descriptions

Descriptions 

Logout from the CLI System 

Display IPM‐4SE current configurations. 

Save current configurations: IPM‐4SE & relative settings. 

Load configuration setting from FLASH. 

Reboot command to use after saving configuration 

Enter password to change user‐mode. (i.e. View/Setup/Admin mode) 

PS: If inputted password is not for "setup" or "admin", it will enter the "view" mode. 

Modify password for user‐mode.  mode: ‘s’ for setup mode, ‘a’ for admin mode. 

Set IPM‐4SE IP address, net mask and gateway IP address.   ip_addr: IP Address, net_mask: net mask, gateway_ip: gateway IP. 

EX: ipset 192.168.1.28 255.255.255.0 192.168.1.254 

Get IPM‐4SE current IP address, net mask, and gateway IP address. 

Set SNMP Trap Mode & Host IP  mode: 0 for disabling SNMP trap, 1 for enabling SNMP trap 

EX: trapset 1 192.168.6.3 (enables trap sending to 192.168.6.3 manager) 

Get SNMP Trap Mode & Host IP 

Set NTP Enable Mode & NTP Server IP  mode: 0 for disable NTP function, 1 for enable NTP function 

Get NTP Enable Mode & NTP Server IP 

Upgrade Software image file from TFTP server  server_ip: TFTP server IP address  file_name: SW image file name 

EX: upgrade 192.168.2.199 ipm130.bin 

Backup the system configuration to TFTP server  tftp_server_ip: the TFTP server IP address  file_name: the backup file name 

EX: backup 192.168.2.199 ipm4se_co_backup_1 

Restore the system configuration from TFTP server  tftp_server_ip: the TFTP server IP address  file_name: the backup file name 

EX: restore 192.168.2.199 ipm4se_co_backup_1 

Set TG Mode   mode: 0 for Global mode, 1 for E1‐Indep mode 

Set Channel Timing Gen Clock Source  ch_no: E1 channel number.  clksrc: 0:Adaptive (remote), 1:Internal, 2:E1 Recovery, 3:Bits. 

Set TG Clock Priority Source   source: 0:Ext.BITS, 1:Global.TG, 2:HoldOver, 3:FreeRun 

Set TG Secondary Clock Source Input  e1_num: 1 ~4 for E1#1 ~ E1#4 

Get TG Mode and Status 

Set current time with ‘hour’, ‘minute’ and ‘second’. 

Set current date with ‘year’, ‘mouth’ and ‘day’ 

Get current time and date 

Enable/Disable E1 channel loopback mode. ch_no: E1 channel number. mode: 0:Disable-All, 1:E1-Remote (FE), 2:E1-Local (NE) enable: 0:disable, 1:enable.

EX: lpkset 1 1 1

Get current loopback mode of E1 channel.

Use ICMP to check connection

EX: ping 192.168.1.28

16

Chapter 3 Configuration and Operation

CLI Command  eberset ch_no enable threshold  ceschtgpriset ch_no 1st.source 

2nd.source  ceschvlanvlpid  ch_no  vlp  id  eberget 

Alarm Command 

Descriptions 

Provisioning Commands  gci  cesopget  srcnet ip_addr net_mask gateway_ip  lanset enable bandwidth 

Initialize GCI Middle Ware & CESoPSN chip 

Initialize relative Tasks, Messages and Semaphores. 

CAUTION: This will clear all the configuration. 

Get current CESoPSN Setting. 

Set CESoPSN IP address, net mask and gateway IP address.   ip_addr: IP Address, net_mask: net mask, gateway_ip: gateway IP. 

EX: srcnet 192.169.1.28 255.255.255.0 192.169.1.254 

Set CESoPSN LAN Traffic Enable and Bandwidth.  enable: 0:disable, 1: enable.  bandwidth:  0~15  (0:  50K,  1:100K,  2:150K,  3:200K,  4:250K,  5:300K,  6:350K,  7:400K,

8:800K, 9:1.6M, 10:3.125M, 11:6.25M, 12:12.5M, 13:25M, 14:50M, 15:100M) 

EX: lanset 1 15 (use the rest of BW minus TDM traffic) 

Set Vlan Mode enable/disable  vlanset enable  ceschset ch_no enable dest_ip  dest_mac  cespwidset ch_no TrPWID PrPWID  jitterbd ch_no depth  pktsize ch_no pkt_size  cesfe1mode ch_no enable   

Set CESoPSN Channel Enable, Destination IP and MAC.  ch_no: E1 channel number (1~4)  enable: 0:disable, 1: enable.  dest_ip: destination node IP address.  dest_mac: destination node MAC address 

Situation 1: Set dest_ip, then get dest_mac from far end 

EX: ceschset 1 1 192.168.1.28 

Situation 2: Set dest_ip and dest_mac manually 

EX: ceschset 1  1  192.168.1.28  AA:BB:CC:DD:EE:FF 

Set CESoPSN Channel TrPWID and PrPWID.  ch_no: E1 channel number (1~4) 

TrPWID: Transmit PseudoWire ID. 

PrPWID: Provision PseudoWire ID. 

EX: cespwidset 1 1 1 

Set CESoPSN Channel Jitter Buffer Depth. Initial Jitter DS is 3.  ch_no: E1 channel number (1~4)  depth:  jitter  buffer  depth  0~7  (0:11ms,  1:23ms,  2:40ms,  3:75ms,  4:99ms,  5:145ms, 

6:192ms, 7:239ms) 

EX: jitterbd 1 2 (Suggested default is to set 40 ms for general uplink latency) 

Set CESoPSN Channel Packet Size 

Pkt_size: 0: 1514 Byte,  1: 782 Byte, 2:  178 Byte.  3: 306 Byte.  cesfe1crc ch_no enable    cesfe1tsmap ch_no TsMap   

Set CESoPSN EBER Enable and Threshold.  ch_no: E1 channel number (1~4)  enable: 0:disable, 1: enable.  threshold: 0 ~ 3 (0:10^‐3, 1:10^‐4, 2:10^5, 3:10^‐6) 

Set CESoPSN Channel clock priority source in TG mode 

Source: 1:E1.TG, 2:HoldOver, 3:FreeRun. 

Set CESoPSN Channel vlan tag  vlp:0 ~ 7, id: 0 ~ 0xFFF 

Get CESoPSN EBER Enable and Threshold.  almall  Display all alarm status (CESoPSN) 

Table 3.1 CLI Command Descriptions

17

Chapter 3 Configuration and Operation

3.10 Factory Default Scripts

When delivered from the factory, the units are paired as CO and CPE for immediate point-to-point use, with all 4 E1s enabled, unframed, and LAN enabled. Because these units operate at Ethernet Layer 2, we address the remotely connected pseudowire by MAC address.

If the device sticker has been lost, or if the MAC address has been inadvertently changed, the MAC for both the MNT port and WAN port can be viewed through the CLI. Below is an example.

3.10.1 Determine Device MAC Address

CLI> m 4321

====== CLI: MW Test Functions ====== m 4321 OUI(xx:xx:xx)

===== Config: HW/SW MAC = 1 (HW_MAC).

===== Config: OUI-Addr = 00:02:AB.

===== Config: eth0 Addr = 00:02:AB:16:CD:13. <== this is NMS MAC Source

===== Config: eth1 Addr = 00:02:AB:16:CD:12. <== this is WAN MAC Source

3.10.2 CO Unit Factory Default Script

CO default, replace xx:xx:xx with CPE unit’s unique MAC Address gci srcnet 172.16.1.1 255.255.255.0 ipset 192.168.1.11 255.255.255.0 172.16.1.2 ceschset 1 1 172.16.1.2 00:02:AB:xx:xx:xx ceschset 2 1 172.16.1.2 00:02:AB:xx:xx:xx ceschset 3 1 172.16.1.2 00:02:AB:xx:xx:xx ceschset 4 1 172.16.1.2 00:02:AB:xx:xx:xx cespwidset 1 1 1 cespwidset 2 2 2 cespwidset 3 3 3 cespwidset 4 4 4 pktsize 1 0 pktsize 2 0 pktsize 3 0 pktsize 4 0 jitterbd 1 1 jitterbd 2 1 jitterbd 3 1 jitterbd 4 1 ceschclkset 1 2 ceschclkset 2 2 ceschclkset 3 2 ceschclkset 4 2 lanset 1 7 csave

18

Chapter 3 Configuration and Operation

3.10.3 CPE Unit Factory Default Script

CPE default, replace xx:xx:xx with CO unit's unique MAC address gci srcnet 172.16.1.2 255.255.255.0 ipset 192.168.2.11 255.255.255.0 172.16.1.1 ceschset 1 1 172.16.1.1 00:02:AB:xx:xx:xx ceschset 2 1 172.16.1.1 00:02:AB:xx:xx:xx ceschset 3 1 172.16.1.1 00:02:AB:xx:xx:xx ceschset 4 1 172.16.1.1 00:02:AB:xx:xx:xx cespwidset 1 1 1 cespwidset 2 2 2 cespwidset 3 3 3 cespwidset 4 4 4 pktsize 1 0 pktsize 2 0 pktsize 3 0 pktsize 4 0 jitterbd 1 1 jitterbd 2 1 jitterbd 3 1 jitterbd 4 1 ceschclkset 1 0 ceschclkset 2 0 ceschclkset 3 0 ceschclkset 4 0 lanset 1 7 csave

The factory default scripts allow the units to connect with 4xE1 over any LAN environment. To quickly modify these two scripts for your LAN:

1. Change the ‘srcnet’ IP address to the new IP you want for the WAN port.

2. Change the ‘ipset’ to the IP, Subnet and GW for the MNT (management) port.

3. Change the ‘ceschset’ IP address to be the WAN destination for the PW (the opposite IPM)

4. Make sure the ‘ceschset’ MAC address is the actual MAC address of the destination unit (opposite

IPM).

19

Chapter 3 Configuration and Operation

3.11 Application Examples

3.11.1 Point-to-Point with single E1 (port1) and LAN port active.

CO Side: (use the correct MAC address for the remote CPE unit) gci srcnet 172.16.1.1 255.255.255.0 ipset 192.168.1.11 255.255.255.0 172.16.1.2 ceschset 1 1 172.16.1.2 00:02:AB:xx:xx:xx cespwidset 1 1 1 pktsize 1 0 jitterbd 1 1 ceschclkset 1 2 lanset 1 7 csave

CPE Side: (use the correct MAC address for the local CO unit) gci srcnet 172.16.1.2 255.255.255.0 ipset 192.168.2.11 255.255.255.0 172.16.1.1 ceschset 1 1 172.16.1.1 00:02:AB:xx:xx:xx cespwidset 1 1 1 pktsize 1 0 jitterbd 1 1 ceschclkset 1 0 lanset 1 7 csave

3.11.2 Point-to-Point with Single E1 (port 1), Fractional /w CRC4 (nx64, n=8) active.

CO Side: (use the correct MAC address for the remote CPE unit) gci srcnet 172.16.1.1 255.255.255.0 ipset 192.168.1.11 255.255.255.0 172.16.1.2 ceschset 1 1 172.16.1.2 00:02:AB:xx:xx:xx cespwidset 1 1 1 pktsize 1 0 jitterbd 1 1 ceschclkset 1 2 cesfe1mode 1 1 cesfe1crc 1 1 cesfe1tsmap 1 x000001FE lanset 0 csave

20

Chapter 3 Configuration and Operation

CPE Side: (use the correct MAC address for the local CO unit) gci srcnet 172.16.1.2 255.255.255.0 ipset 192.168.2.11 255.255.255.0 172.16.1.1 ceschset 1 1 172.16.1.1 00:02:AB:xx:xx:xx cespwidset 1 1 1 pktsize 1 0 jitterbd 1 1 ceschclkset 1 0 cesfe1mode 1 1 cesfe1crc 1 1 cesfe1tsmap 1 x000001FE lanset 0 lanset 1 7 csave

3.11.3 Notes on Fractional E1 Operation

If IPM carries E1 as 'unframed', then it becomes transparent (SAToP). As long as the equipment on both sides of IPM equipment have the same framing, then there will be no alarms. However, the advantage of using framing (CESoPSN) is that the data bandwidth can be reduced considerably by sending only the payload, especially over a satellite link. You must make sure the right timeslots are enabled and match the crc4 if enabled or not (cesfe1crc). Duplicate these settings on both IPM4SE units.

For the hex to timeslot bit mask, each TS is represented by a bit:

TS bits : 11111111111111111111111111111111

TS # 33222222222211111111110000000000

31~0 10987654321098765432109876543210

If we breakup into octets, then we can assign hex values:

1111|1111|1111|1111|1111|1111|1111|1111

F | F | F | F | F | F | F | F

So, if we want to enable fifteen timeslots, starting with TS1:

0000|0000|0000|0000|1111|1111|1111|1110

0 | 0 | 0 | 0 | F | F | F | E

The cesfe1tsmap value would be x0000FFFE

If the timeslot range always starts at TS1, this table will work for you: hex map no. of TS x00000002 = 1 x00000006 = 2 x0000000E = 3 x0000001E = 4 x0000002E = 5 x0000006E = 6 x000000FE = 7 x000001FE = 8 x000002FE = 9 x000006FE = 10 x00000FFE = 11 x00001FFE = 12 x00002FFE = 13 x00006FFE = 14 x0000FFFE = 15 x0001FFFE = 16 x0002FFFE = 17 x0006FFFE = 18 x000FFFFE = 19 x001FFFFE = 20 x002FFFFE = 21 x006FFFFE = 22 x00FFFFFE = 23 x01FFFFFE = 24 x02FFFFFE = 25 x06FFFFFE = 26 x0FFFFFFE = 27 x1FFFFFFE = 28 x2FFFFFFE = 29 x6FFFFFFE = 30 xFFFFFFFE = 31

21

Chapter 3 Configuration and Operation

3.11.4 Using the IPM in a Routing Environment

The IPM-4SE is designed for use in an Ethernet environment (Layer 2). However, with proper configuration, the IPM-4SE will work in a routing environment. Knowing the Router MAC is the key. It is very easy to discover the router’s MAC address. From a PC, open a command window, ping the gateway, then check the ARP table using the command arp –a. Make note of the gateway MAC on each subnet that has an

IPM.

It is also very important to assign the right IP address to MNT port. The MNT port MUST be set to different subnet from WAN port. If the MNT port and WAN port are set to the same subnet, IPM-4 may not know where to route its packets, i.e., to the Router via MNT or WAN port. If it routes packets via MNT port, the CESoTDM packets will not be delivered to Router for forwarding to the remote side.

CO CPE

10.10.1.1/24

WAN

MNT

10.10.3.1

CO Side

RS-232 115.2k

10.10.1.20

10.10.1.254/24

00:48:54:5c:ca:fc

CLI> m 4320 0 <== Set to SW MAC mode

CLI> csave

10.10.2.254/24

00:40:f4:47:ba:24

10.10.2.1/24

WAN

MNT

10.10.4.1

CLI> reboot

CLI> gci

CLI> srcnet 10.10.1.1 255.255.255.0

<== CO_Wan_IP Mask

CLI> ipset 10.10.3.1 255.255.255.0 10.10.1.254

<== MNT_IP Mask Default_GW

CLI> ceschset 1 1 10.10.2.1 00:48:54:5c:ca:fc <== ch_no en remote_ip GW_MAC

CLI> cespwidset 1 1 1

CLI> pktsize 1 1

CLI> jitterbd 1 1

CLI> ceschclkset 1 0

CLI> lanset 1 7

CLI> cs

CPE Side

CLI> m 4320 0

CLI> csave

CLI> reboot

CLI> gci

CLI> srcnet 10.10.2.1 255.255.255.0

<== CPE_Wan_IP Mask

CLI> ipset 10.10.4.1 255.255.255.0 10.10.2.254

<== MNT_IP Mask Default_GW

CLI> ceschset 1 1 10.10.1.1 00:40:f4:47:ba:24 <== ch_no en remote_ip GW_MAC

CLI> cespwidset 1 1 1

CLI> pktsize 1 1

CLI> jitterbd 1 1

CLI> ceschclkset 1 0

CLI> lanset 1 7

CLI> cs

22

Appendix

Abbreviations

DSU/CSU Digital Service Unit/Channel Service Unit

Remote Indication

LOS/LOF/PATH Loss of Signal/Frame/Path Alarm

Plesiochronous Hierarchy

23

Appendix

This page left blank intentionally.

Appendix

24

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals