EXTECH EX300 Series Digital Multimeters User Guide
Add to my manuals
8 Pages
Extech EX300 Series is a versatile line of mini digital multimeters with built-in non-contact voltage detectors. These affordable and portable devices are ideal for a wide range of electrical testing applications, including voltage, current, resistance, capacitance, and temperature measurements. With their compact size and user-friendly interface, EX300 Series multimeters are perfect for electricians, technicians, hobbyists, and DIY enthusiasts alike.
advertisement
EX300 Series Multimeters
Digital Multimeter (DMM) Index Guide
Pick the right Multimeter for your application
6
MN Series
Compact and affordable
Digital Multimeters with choice of Manual
Ranging or Autoranging models. Perfect for
DIYers, students, hobbyists, mechanics and technicians.
p. 13
EX300 Series
Mini Digital DMMs with built-in Non-Contact
Voltage Detector and numerous electrical functions and temperature.
p. 6
EX350 Series
These professional
True RMS DMMs are loaded with advanced features and functions.
Low Impedance (LoZ) mode eliminates false readings caused by ghost voltages. Low Pass Filter
(LPF) attenuates high frequencies to reduce noise for accurate readings. p. 7
EX360 Series
Professional CAT IV
True RMS Multimeters designed for Electrical,
HVAC, or Industrial
Applications. Advanced
LoZ feature eliminates false readings caused by ghost voltages.CAT IV safety rating ensures the highest level of protection.
p. 8
EX400A Series
Professional Full
Size Series Digital
Multimeters. Features include Large Digits,
True RMS or Averaging, and Type K and/or built-in
IR Thermometer.
p. 9
EX500 Series
Industrial Series Digital
DMMs are accurate and rugged. Waterproof, dustproof, drop tested to 2 m (6.5’), and CAT IV safety rated for higher voltage applications.
Wireless datalogging model or built-in IR
Thermometer.
p. 10
Look for this symbol: indicating products that are available with optional calibration traceable to NIST. See complete listing on p. 146-167.
MG320 Series
Combines a 1000 V
Insulation Resistance
Tester with Resistance range up to 200 GΩ and a fully-loaded True RMS
CAT IV Digital Multimeter. p. 12
EX300
Series Mini Digital Multimeters + Voltage Detector
Combination Multimeter with non-contact AC Voltage Detector
• Built-in non-contact AC Voltage Detector with red LED indicator and audible beeper
• Large 1" digits makes display easy to read
• CAT III-600 V, CAT II-1000 V safety rating
• 2-year warranty
• Complete with stand, test leads, protective holster, batteries, general purpose Type K bead wire temperature probe (EX330 only)
Model EX310 (Manual Ranging)
• Battery test 1.5 V and 9 V
Model EX330 (Autoranging)
• Data Hold and Auto Power Off
• Advanced functions include Type K Temperature, Capacitance, and Frequency
SPECIFICATIONS
Display Count
Basic Accuracy
NCV Detector
DC Voltage
AC Voltage
DC/AC Current
Resistance
Capacitance
Frequency
Temperature
Duty Cycle
Diode/Continuity
Dimensions
Weight
EX310 (MANUAL RANGING)
2000
0.50%
100 to 600 V AC
0.1 mV to 600 V
0.1 V to 600 V
0.1 mA to 10 A
0.1 Ω to 2000 k Ω
—
—
—
—
Yes
5.7x2.9x1.6" (147x76x42 mm)
9 oz (260 g)
EX330 (AUTORANGING)
4000
0.50%
100 to 600 VAC
0.1 mV to 600 V
0.1 mV to 600 V
0.1 μA to 10 A
0.1 Ω to 40 M Ω
0.001 nF to 200 μF
0.001 Hz to 10 MHz
-4 to 1382°F (-20 to 750°C)
0.1 to 99.9%
Yes
5.7x2.9x1.6" (147x76x42 mm)
9 oz (260 g)
Integrated Non-Contact
Voltage Detector for quickly checking the presence of live wires before testing.
ORDERING
EX310
EX330
409996
TP873
TL803
Manual Ranging 9 Function Mini Multimeter + Non-Contact Voltage Detector
Autoranging 12 Function Mini Multimeter + Non-Contact Voltage Detector
Vinyl soft case
Replacement Bead wire Temperature Probe (-22 to 572°F/-30 to 300°C)
Replacement Test Leads
Indicates products that are available with optional calibration traceable to NIST.
See pages 146-147 for a complete listing.
EX350 Series Professional Multimeters
EX350
Series True RMS Multimeters with LPF and LoZ
EX350
EX355 with Temperature
Professional meters loaded with advanced features and functions including
Low Pass Filter (LPF) and Low Impedance (LoZ)
• True RMS for accurate AC measurements
• 0.5% basic accuracy
• Low Pass Filter (LPF) for accurate measurement of variable frequency drive signals
• LoZ prevents false readings caused by ghost voltages
• Built-in Non-Contact AC Voltage Detector (NCV) with LED indicator
• Data Hold freezes the reading on the display
• Min/Max/Max-Min captures highest and lowest readings and the difference between them
• Relative Mode for Capacitance Zero and offset adjustment
• Continuity and Diode Test
• Auto Power Off conserves battery life
• CAT III-600 V safety rating
• 3-year warranty
Model EX350
• 4000 count backlit LCD display
• Complete with test leads and two AA batteries
Model EX355
• 6000 count backlit LCD display
• Type K Temperature
• Complete with test leads, two AA batteries, and general purpose bead wire temperature probe
SPECIFICATIONS
Display Count
Basic DCV Accuracy
NCV Detector
DC/AC Voltage
DC/AC Current
Resistance
Capacitance
Frequency
Temperature (Type K)
Duty Cycle
Diode Test
Continuity
Dimensions/ Weight
EX350
4000
±0.5%
Yes
EX355
6000
±0.5%
Yes
0.01 mV to 600 V
0.1 μA to 10.00 A
0.1 Ω to 40.00 M Ω
1 pF to 60.00 mF
0.001 Hz to 10 MHz
—
0.1 to 99.9%
3.2 V
0.01 mV to 600 V
0.1 μA to 10.00 A
0.1 Ω to 60.00 M Ω
1 pF to 60.00 mF
0.001 Hz to 10 MHz
-40 to 1832°F (-40 to 1000°C)
0.1 to 99.9%
3.2 V
Audible Audible
6.7x3.2x1.9" (175x81x48.5 mm)/13.1 oz (370 g)
Low Pass Filter (LPF) ensures accurate
AC Voltage measurements on a variable frequency drive.
ORDERING
EX350
EX355
TL810
TL803
TP200
True RMS Multimeter + NCV
True RMS Multimeter + NCV + Temperature
Electrical Test Lead Kit
Standard Test Leads
Type K Clamp Probe (212°F/100°C)
Calibration Traceable to NIST
A NIST traceable certificate with data is available when you order your meter with
Certificate Traceable to NIST. Look for this symbol next to product part numbers.
Verify Temperature output on HVAC units using Model EX355
For the name of your local stocking distributor, visit www.extech.com
7
CAT IV Electrical, HVAC, and Industrial Multimeters
EX360 Series
CAT IV True RMS Multimeters + NCV + LoZ
Model EX360
Electrical DMM
Model EX363
HVAC DMM
Choose a CAT IV-600 V multimeter designed for Electrical, HVAC, or
Industrial Applications with LoZ function for accurate Voltage readings
• True RMS for accurate AC measurements
• LoZ prevents false readings caused by ghost voltages
• Built-in Non-contact AC Voltage Detector (NCV) with LED indicator
• Smart Data Hold freezes the displayed reading and automatically updates the reading and alerts user (audibly and visually) if the measurement changes ±50 counts
• Large white LED backlit display with 60-segment analog bargraph for viewing trends
• Peak Hold captures the highest reading
• Relative Mode for Capacitance Zero and offset adjustment
• Continuity beeper with visual alert; Auto Power off with disable
• CAT IV-600 V safety rating
• 2-year warranty
Model EX360 — for Electrical applications
• Frequency and Capacitance measurement
Model EX363 — for HVAC applications
• μA function for HVAC flame rod measurements
• Type K Temperature
• Frequency and Capacitance measurement
Model EX365 — for Industrial/Commercial applications
• 10 A AC/DC Current measurement with 11 A/1000 V high energy fuse
• Frequency and Capacitance measurement
Model EX365
Industrial DMM
Includes test leads, 9 V battery, holster with tilt stand and built-in magnet, and general purpose bead wire temperature probe (Model EX363)
SPECIFICATIONS
Display Count
Basic Accuracy (DCV)
NCV Detector
DC/AC Voltage
DC/AC Current
DC/AC μA Current
Resistance
Capacitance
Frequency
Temperature (Type K)
Diode Test/Continuity
Dimensions/ Weight
EX360 EX363 EX365
6000
0.5%
Yes
0.1 mV to 1000 V
—
—
0.1 Ω to 40 M Ω
1 nF to 10 mF
6000
0.5%
Yes
0.1 mV to 1000 V
—
600 μA
0.1 Ω to 40 M
1 nF to 10 mF
Ω
6000
0.5%
Yes
0.1 mV to 1000 V
1 mA to 10 A
—
0.1 Ω to 40 M
1 nF to 10 mF
Ω
0.01 Hz to 100 kHz
—
Yes
0.01 Hz to 100 kHz 0.01 Hz to 100 kHz
-40 to 742°F (-40 to 394°C) —
Yes
6.5x3.2x1.7" (164x82x44 mm)/5.9 oz (450 g)
Yes
ORDERING
EX360
EX363
EX365
Electrical CAT IV True RMS Multimeter + NCV
HVAC CAT IV True RMS Multimeter + NCV
Industrial CAT IV True RMS Multimeter + NCV
Benefits of LoZ Function
ON ON ON OFF
ON ON
OFF
ON
OFF
ON
OFF
OFF No LoZ function – picks up reading from ghost voltages
LoZ function – prevents false readings from ghost voltages
8
Indicates products that are available with optional calibration traceable to NIST.
See pages 146-147 for a complete listing.
EX400 Series Professional Multimeters
EX400A
Series Professional Multimeters
EX410A
EX430A
Models with or without the built-in Infrared Thermometer, auto or manual ranging, True RMS or averaging
• Large backlit LCD display with easy-to-read 1" digits
• Type K thermometer built-in for temperature measurements
• Low current capability: measure down to 0.1 μA
• Input fuse protection and mis-connection warnings
• CAT III-600 V safety rating
• Complete with CAT III test leads, multi-position tilt stand and velcro strap for hanging, protective holster with test lead holder, bead wire temperature probe, and 9 V battery
Model EX410A (Manual Ranging)
• Averaging multimeter
• 2-year warranty
Model EX430A (Autoranging)
• True RMS for accurate AC measurements
• Relative function
• 3-year warranty
Model EX470A (Autoranging)
• Built-in non-contact Infrared (IR) Thermometer
• True RMS for accurate AC measurements
• Relative function
• 3-year warranty
EX470A
DMM+IR Thermometer
Built-in non-contact
IR Thermometer allows you to safely perform non-contact temperature scans.
SPECIFICATIONS EX410A EX430A EX470A
Display Count
Temperature (IR)
2000
—
Averaging/True RMS Averaging
Basic Accuracy (VDC) ±0.5%
AC Voltage 1 mV to 600 V
DC Voltage
AC Current
DC Current
Resistance
Capacitance
Frequency
Temperature (Type K)
Duty Cycle
Diode Test/Continuity
Dimensions/ Weight
4000
—
True RMS
±0.3%
0.1 mV to 600 V
4000
58 to 518°F (-50 to 270°C)
True RMS
±0.3%
0.1 mV to 600 V
0.1 mV to 600 V
0.1 μA to 10 A
0.1 μA to 10 A
0.1 Ω to 20 M Ω
—
0.1 mV to 600 V
0.1 μA to 10 A
0.1 μA to 10 A
0.1 Ω to 40 M Ω
0.01nF to 100μF
0.1 mV to 600 V
0.1 μA to 10 A
0.1 μA to 10 A
0.1 Ω to 40 M Ω
0.01 nF to 100 μF
— 0.001 Hz to 10 MHz 0.001 Hz to 10 MHz
-4 to 1382°F (-20 to 750°C) -4 to 1382°F (-20 to 750°C) -4 to 1382°F (-20 to 750°C)
—
Yes
0.1% to 99.9%
Yes
7.4x3.2x2" (187x81x50 mm)/0.75 lbs (342 g)
0.1% to 99.9%
Yes
Watch the
Video
www.extech.com/video
ORDERING
EX410A
EX430A
EX470A
TL810
TL803
TP200
HG500
Manual Ranging Multimeter
True RMS Autoranging Multimeter
True RMS Autoranging Multimeter + IR Thermometer
Electrical Test Lead Kit
Standard Test Leads
Type K Clamp Probe (212°F/100°C)
Magnetic Hanging Strap
Extech-exclusive Meters with Built-in IR Thermometer!
Our innovative design incorporates a built-in IR Thermometer. Look for the built-in IR Thermometer logo throughout this catalog.
Multimeters Clamp Meters Psychrometers Humidity Meters Moisture Meters Tachometers Air Flow Meters
For the name of your local stocking distributor, visit www.extech.com
9
EX500 Series CAT IV Waterproof Industrial Multimeters
EX500
CAT IV Heavy Duty True RMS Multimeters
EX505
EX520
EX530
Waterproof (IP67)/drop proof (6.5 ft/2 m) rugged design for heavy duty use
• True RMS for accurate AC measurements
• 1000 V input protection on all functions
• Dual sensitivity frequency functions; Diode open circuit voltage of 2.8 V DC
• Auto Power Off with disable feature
• CAT IV-600 V safety rating
• 3-year warranty
Model EX505
• 4,000 count backlit LCD
• 0.5% basic accuracy
• Data Hold, Relative, and 10 A max Current
Model EX520
• 6000 count—high resolution backlit LCD
• 0.09% basic accuracy
• Min/Max, Data Hold, Relative, and 20 A max Current
Model EX530
• 40,000 count—highest resolution backlit LCD
• 0.06% basic accuracy
• Min/Max, Data Hold, Relative, 20 A max Current, and Peak Hold (AC only)
Complete with double molded test leads, magnetic hanging strap, general purpose Type K bead wire temperature probe, soft case, and one 9 V battery
Watch the
Video
www.extech.com/video
SPECIFICATIONS EX505 EX520 EX530
Basic Accuracy
DC Voltage
±0.5%
0.1 mV to 1000 V DC
AC Voltage 0.1 mV to 1000 V AC
DC/AC Current
Resistance
Capacitance
0.1 μA to 10 A
0.1 Ω to 40 M Ω
0.01 nF to 100 μF
Frequency (electrical) 5 Hz to 1 kHz
±0.09%
0.1 mV to 1000 V DC
1 mV to 1000 V AC
0.1 μA to 20 A
0.1 Ω to 40 M Ω
0.01 nF to 1000 μF
10 Hz to 400 Hz
±0.06%
0.01 mV to 1000 V DC
0.01 mV to 1000 V AC
0.01 μA to 20 A
0.01 Ω to 40 M Ω
0.001 nF to 40 mF
40 Hz to 400 Hz
Frequency (electronic) 0.001 Hz to 10 MHz 0.001 Hz to 40 MHz 0.001 Hz to 100 MHz
Temperature (Type K) -4 to 1382°F/-20 to 750°C -4 to 1382°F/-20 to 750°C -4 to 1382°F/-20 to 750°C
Duty Cycle
Diode/Continuity
Dimensions/Weight
0.1 to 99.9%
Yes/Audible
0.1 to 99.9%
Yes/Audible
7.25x3.25x2.25" (184x83x57 mm)/12.3 oz (349 g)
0.1 to 99.9%
Yes/Audible
Waterproof (IP67) rugged double molded design for heavy duty application use
ORDERING
EX505
EX520
EX530
TL810
TL805
HG500
True RMS Industrial Multimeter (4000 count)
True RMS Industrial Multimeter (6000 count)
True RMS Industrial Multimeter (40,000 count)
Electrical Test Lead Kit
Double Injected Test Leads
Magnetic Hanging Strap
10
EX505-K
Heavy Duty Industrial Multimeter Kit
CAT IV Multimeter and AC Voltage Detector With 8 piece test lead kit
• Kit includes EX505 True RMS waterproof (IP67)/drop-proof Multimeter, DV25
Dual Range Non-contact AC Voltage Detector + Flashlight, TL808 8-piece
Professional Test Lead Kit, plus professional double-molded test leads, Type K thermocouple bead probe with banana input adaptor, and magnetic hanging strap
• Supplied in a soft carrying case that provides protection and organization for the meters and accessories
• Dimensions: 9.8x8x2" (248x203x51 mm); Weight: 1.2 lbs (544 g)
Model EX505: Industrial grade, CAT IV-600 V, 4000 count display, waterproof (IP67),
CE/UL listed, drop-proof, rugged multimeter with True RMS functions (see p. 10 )
Model DV25: Dual Range Non-Contact Voltage (NCV) Detector (24 to 1000 V AC/100 to 1000 V AC) + Flashlight with Audible/ Visual indication, and double-molded housing
CAT IV-1000 V, CE/UL (see p. 28 )
Model TL808: 8-Piece Professional Test Lead Kit with CAT III-1000 V rating
ORDERING
(VISIT WWW.EXTECH.COM FOR PRODUCT SPECIFICATIONS)
EX505-K Heavy Duty Industrial Multimeter Kit
Indicates products that are available with optional calibration traceable to NIST.
See pages 146-147 for a complete listing.
Bluetooth ® Wireless Datalogging Multimeter
MM750W
Wireless Datalogging CAT IV True RMS Multimeter
DAT12 included
Using the Wireless connectivity feature, Bluetooth ® datalogging module, and free app, you can transmit readings right to your iOS ® or Android ™ devices
Multimeter Features
• Wireless DMM function with Bluetooth Datalogging Module transmits readings to iOS and Android devices for remote viewing using the free app
• True RMS for accurate AC measurements
• Type K Temperature function
• Large backlit LCD display
• ±0.6% basic DCV accuracy
• Built-in Non-Contact AC Voltage Detector (NCV)
• AC μA function ideal for HVAC flame rod current measurement
• External clamp adapter input (1 mV=1 A; 600 A AC/DC max)
• MIN/MAX/DIF captures highest & lowest readings and the difference between them
• Relative Mode for Capacitance Zero and offset adjustment
• Data Hold freezes the reading on the display
• Auto Power Off with disable and low battery indicator
• CAT IV-600 V, CAT III-1000 V safety category
• 2 year warranty
• Complete with test leads, general purpose Type K bead wire temperature probe,
Wireless Datalogging Module (DAT12), 9 V battery, and soft case
Wireless Datalogging Features
• Bluetooth Datalogging Module (DAT12) can record over 15k readings and transmit them to a smart device
• Free ExView ® W-Series App, provides Wireless Data Streaming with real-time remote viewing of readings
• Adjustable sample rate and file size support most application needs
• Record data directly to phone or tablet
• Programmable High/Low audible alarms
• Export data in Excel ® format
• Share data files and snapshots directly from application
• Take snapshots of the measurement area with your connected smart phone or tablet camera to capture measurement-related images and to document date/time stamps and measurement data
Using the wireless feature, Bluetooth ® Datalogging
Module, and the free ExView ® W-Series App, you can transmit readings in real-time to your smart devices, store over 15k readings for wireless transfer to generate a report/data analysis, add notes and readings to photos taken from your smart device camera, and use your smart device as a 2nd display for easy viewing or sharing.
Download the Extech ExView ™ W-Series App available on App Store or Google Play. NOTE: iOS/
Android device not included.
Apple and the Apple logo are trademarks of Apple Inc., registered in the
U.S. and other countries. App Store is a service mark of Apple Inc.
Google Play and the Google Play logo are trademarks of Google LLC.
SPECIFICATIONS
AC Current
DC Current
AC μA Current
DC μA Current
Resistance
Capacitance
Frequency
Temperature (Type K)
Duty Cycle
Diode Test
Continuity
Datalogging (with DAT12)
Dimensions/Weight
RANGE
Display Count 6000
Non-Contact Voltage (NCV) >100 V AC
AC Voltage
DC Voltage
0.1 mV to 1000 V
0.1 mV to 1000 V
MAX RESOLUTION
0.1 mV
0.1 mV
BASIC ACCURACY
±0.6% of rdg ±3 digits
±0.6% of rdg ±2 digits
0.1 μA to 10.00 A
0.1 μA to 10.00 A
0.1 μA to 6000 μA
0.1 μA to 6000 μA
0.1 Ω to 60.00 M Ω
9.999 nF to 99.99 mF
9.999 Hz to 55.00 MHz
-40 to 1832°F
(-40 to 1000°C)
0.1 μA
0.1 μA
0.1 μA
0.1 μA
0.1 Ω
0.001 nF
0.001 MHz
1°
±0.15% of rdg ±5 digits
±0.12% of rdg ±5 digits
±0.15% of rdg ±5 digits
±0.12% of rdg ±5 digits
±0.6% of rdg ±2 digits
±5% of rdg ±5 digits
±1.5% of rdg ±3 digits
±(2%+2°F) / ±(2%+2°C)
0.1 to 99.9%
3.000 V
Audible
15,360 data points
0.10%
0.001 V
±1.2% of rdg ±2 digits
±10% of rdg ±5 digits
7.4x3.8x2.2" (188x96x56 mm) / 14.6 oz (415 g) without battery
ORDERING
MM750W
TL810
TL803
DAT12
Wireless Datalogging CAT IV True RMS Multimeter
Test Lead Kit
Standard Test Leads
Replacement Bluetooth ® Wireless Datalogging Module
For the name of your local stocking distributor, visit www.extech.com
11
Combination Multimeters/Insulation Testers
MG320/MG325
CAT IV Insulation Tester/True RMS Multimeters
Combines a portable Insulation Tester with a CAT IV True RMS Multimeter
• 5 Test Voltage ranges up to 1000 V
• Polarization Index (PI) and Dielectric Absorption Ratio measurements (DAR)
• Low Resistance measurement with Zero function
• Programmable Timer feature sets the duration of test
• Comparison Mode allows user to set the Pass/
Fail values for insulation measurements
• Step Voltage (10% steps at 50% to 120% of range)
• Auto-discharge of voltage test signal
• Lock Power-On function for hands-free operation
• Manually store/recall up to 99 readings
• High voltage and overloa d indication
• Data Hold to freeze displayed reading
• Auto Power Off and low battery indication
• CAT IV-600 V safety category
• 2-year warranty
Model MG320
• Measures Insulation Resistance to 20 G
Ω
• Backlit 6,000 count display with analog bargraph
• Complete with test leads, alligator clip, 6 x AA batteries, and soft case
Model MG325
• Measures Insulation Resistance to 200 G
Ω
• Backlit 10,000 count display with analog bargraph
• View the Frequency (45 Hz ~ 400 Hz) of AC Voltage measurements
• Remote probe with built-in TEST button allows for quick on-spot testing
• LED high voltage and LCD overload indication
• Measures Leakage Current, Low Resistance, Capacitance, and Frequency
• Complete with remote probe, test leads, alligator clip, 6 x AA batteries, and soft case
SPECIFICATIONS
Insulation Resistance
MG320
50 M Ω , 100 M Ω , 200 M Ω , 500 M Ω ,
2000 M
Ω
, 1 G
Ω
, 10 G
Ω
, 20 G
Ω
MG325
50 M Ω , 100 M Ω , 200 M Ω , 500 M Ω ,
2000 M
Ω
, 1 G
Ω
, 10 G
Ω
, 20 G
Ω
, 50 G
Ω
,
100 G Ω , 200 G Ω
50 V, 100 V, 250 V, 500 V, 1000 V
600 V
Insulation Test Voltages 50 V, 100 V, 250 V, 500 V, 1000 V
AC/DC Voltage 600 V
Leakage Current
Resistance
Low Resistance
Capacitance
Frequency
Continuity
Dimensions/ Weight
—
20 k Ω
—
—
—
Audible
8.9x4.1x2.3" (225x103x59 mm)/1.5 lbs (0.7 kg)
2000 μA
10 M Ω
100 Ω
500 μF
1 kHZ
Audible
ORDERING
MG320
MG325
CAT IV Insulation Tester/True RMS Multimeter
CAT IV Insulation Tester/ True RMS Multimeter with Remote Test Probe
Checking voltage on a lathe and insulation test on pump motor
12
Indicates products that are available with optional calibration traceable to NIST.
See pages 146-147 for a complete listing.
Compact Multimeters and Pen Multimeter
DM220
CAT IV Pocket Multimeter + NCV
Autoranging DMM with 4000 count LCD display, NCV and built-in Flashlight
• Non-Contact Voltage detection identifies live circuits
• Rugged double molded housing; CAT IV-600 V, CAT III-1000 V safety rating
Includes test leads and two AAA batteries; 2-year warranty
SPECIFICATIONS
DC/AC Voltage
DC/AC Current
NC Voltage
Resistance
Frequency
Capacitance
Duty Cycle
Diode/Continuity
Dimensions/Weight
RANGE
600 V
200 mA
100 to 600 VAC
40 M Ω
10 kHz
200 μF
MAX RESOLUTION
0.1 mV DC/1 mV AC
0.1 μA
0.1 Ω
0.001 Hz
0.001 nF
0.5 to 99%
Yes/Audible
0.5%
4.72x2.2x1.6" (120x55x540 mm)/5.12 oz (145 g)
BASIC ACCURACY (%RDG)
±0.8% DC/±1.5% AC
±2.0% DC/±2.5% AC
±0.8%
±2.0%
±5.0%
±(2.0% reading + 5 digits)
ORDERING
DM220 CAT IV Pocket Multimeter + NCV
MN35/MN36
Digital Mini Multimeters
Autoranging or Manual ranging multimeters with Temperature function
• Large easy to read digital display
MN35 (Manual Ranging/ 8 Functions)
• 1.5 V and 9 V Battery test
MN36 (Autoranging/ 10 Functions)
• AC Current, Capacitance and Frequency measurements
Includes holster with stand,
Type K bead wire probe, battery, and test leads; 2-year warranty
SPECIFICATIONS
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Capacitance
Frequency
Temperature
Battery Test
Dimensions/Wt
MN35 BASIC ACCURACY MN36
600 V (0.1 mV)
600 V (0.1 V)
10 A (0.1 mA)
—
20 M
—
Ω (0.1 μ Ω )
—
-4 to 1400°F (1°)
-20 to 750°C
±0.5%
±1.2%
±1.5%
—
±0.8%
—
—
±(1%+4°)
600 V (0.1 mV)
600 V (0.1 V)
10 A (0.1 μA)
10 A (0.1 μA)
40 M Ω (0.1 μ Ω )
100 μF (0.001 nF)
5 MHz (0.01 Hz)
-4 to 1400°F (1°)
-20 to 750°C
9 V and 1.5 V
5.43x2.83x1.5" (138x72x38 mm)/5.4 oz (153 g)
—
BASIC ACCURACY
±0.5%
±1.2%
±1.2%
±1.5%
±1.2%
±3.0%
±1.0%
±(1%+4°)
ORDERING
MN35
MN36
Manual Ranging Mini Digital Multimeter
Autoranging Mini Digital Multimeter
381676A
Pen DMM with Non-Contact Voltage Detector
Autoranging multimeter with non-contact voltage detection
• Autoranging with Data Hold, Range Hold, and Maximum Hold features
• CAT III-600 V; Auto power off, overload and low battery indication
• 2-year warranty
Includes test leads, two alligator clips, two 1.5 V
AAA batteries, and soft case
SPECIFICATIONS
Non-contact Voltage
AC/DC Voltage
AC/DC Current
Resistance ( Ω )
Logic Test
Diode/Continuity
Dimensions/Weight
RANGE MAX RESOLUTION BASIC ACCURACY
>110 V AC
200 mV, 2, 20, 200, 600 V 0.1 mV AC: ±0.8%; DC: 0.7%
20 mA, 200 mA 0.01 μA
200, 2 k, 20 k, 200 k, 2 M, 20 M Ω 0.1
Ω
AC: ±2%; DC: 0.1.5%
±0.8%
0 to 1.5 V (Green LED), 1.5 to 3.5 V (LED off), 3.5 to 5 V (Red LED)
Yes/Audible
8.2x1.5x1.1" (208x38x29 mm)/4.6 oz (129 g)
ORDERING
381676A Pen DMM with Non-Contact Voltage Detector
For the name of your local stocking distributor, visit www.extech.com
13
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Built-in non-contact voltage detector for quick and easy voltage detection
- Large, easy-to-read 1" digits for clear visibility
- CAT III-600 V, CAT II-1000 V safety rating for added protection
- 2-year warranty for peace of mind
- Complete with stand, test leads, protective holster, batteries, and general purpose Type K bead wire temperature probe (EX330 only)
Related manuals
Frequently Answers and Questions
What is the basic accuracy of the EX310?
What is the maximum voltage that the EX330 can measure?
What type of temperature probe is included with the EX330?
What is the difference between the EX310 and the EX330?
How long is the warranty on the EX300 Series multimeters?
advertisement