EX300 Series Multimeters

Digital Multimeter (DMM) Index Guide

Pick the right Multimeter for your application

6

MN Series

Compact and affordable

Digital Multimeters with choice of Manual

Ranging or Autoranging models. Perfect for

DIYers, students, hobbyists, mechanics and technicians.

p. 13

EX300 Series

Mini Digital DMMs with built-in Non-Contact

Voltage Detector and numerous electrical functions and temperature.

p. 6

EX350 Series

These professional

True RMS DMMs are loaded with advanced features and functions.

Low Impedance (LoZ) mode eliminates false readings caused by ghost voltages. Low Pass Filter

(LPF) attenuates high frequencies to reduce noise for accurate readings. p. 7

EX360 Series

Professional CAT IV

True RMS Multimeters designed for Electrical,

HVAC, or Industrial

Applications. Advanced

LoZ feature eliminates false readings caused by ghost voltages.CAT IV safety rating ensures the highest level of protection.

p. 8

EX400A Series

Professional Full

Size Series Digital

Multimeters. Features include Large Digits,

True RMS or Averaging, and Type K and/or built-in

IR Thermometer.

p. 9

EX500 Series

Industrial Series Digital

DMMs are accurate and rugged. Waterproof, dustproof, drop tested to 2 m (6.5’), and CAT IV safety rated for higher voltage applications.

Wireless datalogging model or built-in IR

Thermometer.

p. 10

Look for this symbol: indicating products that are available with optional calibration traceable to NIST. See complete listing on p. 146-167.

MG320 Series

Combines a 1000 V

Insulation Resistance

Tester with Resistance range up to 200 GΩ and a fully-loaded True RMS

CAT IV Digital Multimeter. p. 12

EX300

Series Mini Digital Multimeters + Voltage Detector

Combination Multimeter with non-contact AC Voltage Detector

• Built-in non-contact AC Voltage Detector with red LED indicator and audible beeper

• Large 1" digits makes display easy to read

• CAT III-600 V, CAT II-1000 V safety rating

• 2-year warranty

• Complete with stand, test leads, protective holster, batteries, general purpose Type K bead wire temperature probe (EX330 only)

Model EX310 (Manual Ranging)

• Battery test 1.5 V and 9 V

Model EX330 (Autoranging)

• Data Hold and Auto Power Off

• Advanced functions include Type K Temperature, Capacitance, and Frequency

SPECIFICATIONS

Display Count

Basic Accuracy

NCV Detector

DC Voltage

AC Voltage

DC/AC Current

Resistance

Capacitance

Frequency

Temperature

Duty Cycle

Diode/Continuity

Dimensions

Weight

EX310 (MANUAL RANGING)

2000

0.50%

100 to 600 V AC

0.1 mV to 600 V

0.1 V to 600 V

0.1 mA to 10 A

0.1 Ω to 2000 k Ω

Yes

5.7x2.9x1.6" (147x76x42 mm)

9 oz (260 g)

EX330 (AUTORANGING)

4000

0.50%

100 to 600 VAC

0.1 mV to 600 V

0.1 mV to 600 V

0.1 μA to 10 A

0.1 Ω to 40 M Ω

0.001 nF to 200 μF

0.001 Hz to 10 MHz

-4 to 1382°F (-20 to 750°C)

0.1 to 99.9%

Yes

5.7x2.9x1.6" (147x76x42 mm)

9 oz (260 g)

Integrated Non-Contact

Voltage Detector for quickly checking the presence of live wires before testing.

ORDERING

EX310

EX330

409996

TP873

TL803

Manual Ranging 9 Function Mini Multimeter + Non-Contact Voltage Detector

Autoranging 12 Function Mini Multimeter + Non-Contact Voltage Detector

Vinyl soft case

Replacement Bead wire Temperature Probe (-22 to 572°F/-30 to 300°C)

Replacement Test Leads

Indicates products that are available with optional calibration traceable to NIST.

See pages 146-147 for a complete listing.

EX350 Series Professional Multimeters

EX350

Series True RMS Multimeters with LPF and LoZ

EX350

EX355 with Temperature

Professional meters loaded with advanced features and functions including

Low Pass Filter (LPF) and Low Impedance (LoZ)

• True RMS for accurate AC measurements

• 0.5% basic accuracy

• Low Pass Filter (LPF) for accurate measurement of variable frequency drive signals

• LoZ prevents false readings caused by ghost voltages

• Built-in Non-Contact AC Voltage Detector (NCV) with LED indicator

• Data Hold freezes the reading on the display

• Min/Max/Max-Min captures highest and lowest readings and the difference between them

• Relative Mode for Capacitance Zero and offset adjustment

• Continuity and Diode Test

• Auto Power Off conserves battery life

• CAT III-600 V safety rating

• 3-year warranty

Model EX350

• 4000 count backlit LCD display

• Complete with test leads and two AA batteries

Model EX355

• 6000 count backlit LCD display

• Type K Temperature

• Complete with test leads, two AA batteries, and general purpose bead wire temperature probe

SPECIFICATIONS

Display Count

Basic DCV Accuracy

NCV Detector

DC/AC Voltage

DC/AC Current

Resistance

Capacitance

Frequency

Temperature (Type K)

Duty Cycle

Diode Test

Continuity

Dimensions/ Weight

EX350

4000

±0.5%

Yes

EX355

6000

±0.5%

Yes

0.01 mV to 600 V

0.1 μA to 10.00 A

0.1 Ω to 40.00 M Ω

1 pF to 60.00 mF

0.001 Hz to 10 MHz

0.1 to 99.9%

3.2 V

0.01 mV to 600 V

0.1 μA to 10.00 A

0.1 Ω to 60.00 M Ω

1 pF to 60.00 mF

0.001 Hz to 10 MHz

-40 to 1832°F (-40 to 1000°C)

0.1 to 99.9%

3.2 V

Audible Audible

6.7x3.2x1.9" (175x81x48.5 mm)/13.1 oz (370 g)

Low Pass Filter (LPF) ensures accurate

AC Voltage measurements on a variable frequency drive.

ORDERING

EX350

EX355

TL810

TL803

TP200

True RMS Multimeter + NCV

True RMS Multimeter + NCV + Temperature

Electrical Test Lead Kit

Standard Test Leads

Type K Clamp Probe (212°F/100°C)

Calibration Traceable to NIST

A NIST traceable certificate with data is available when you order your meter with

Certificate Traceable to NIST. Look for this symbol next to product part numbers.

Verify Temperature output on HVAC units using Model EX355

For the name of your local stocking distributor, visit www.extech.com

7

CAT IV Electrical, HVAC, and Industrial Multimeters

EX360 Series

CAT IV True RMS Multimeters + NCV + LoZ

Model EX360

Electrical DMM

Model EX363

HVAC DMM

Choose a CAT IV-600 V multimeter designed for Electrical, HVAC, or

Industrial Applications with LoZ function for accurate Voltage readings

• True RMS for accurate AC measurements

• LoZ prevents false readings caused by ghost voltages

• Built-in Non-contact AC Voltage Detector (NCV) with LED indicator

• Smart Data Hold freezes the displayed reading and automatically updates the reading and alerts user (audibly and visually) if the measurement changes ±50 counts

• Large white LED backlit display with 60-segment analog bargraph for viewing trends

• Peak Hold captures the highest reading

• Relative Mode for Capacitance Zero and offset adjustment

• Continuity beeper with visual alert; Auto Power off with disable

• CAT IV-600 V safety rating

• 2-year warranty

Model EX360 — for Electrical applications

• Frequency and Capacitance measurement

Model EX363 — for HVAC applications

• μA function for HVAC flame rod measurements

• Type K Temperature

• Frequency and Capacitance measurement

Model EX365 — for Industrial/Commercial applications

• 10 A AC/DC Current measurement with 11 A/1000 V high energy fuse

• Frequency and Capacitance measurement

Model EX365

Industrial DMM

Includes test leads, 9 V battery, holster with tilt stand and built-in magnet, and general purpose bead wire temperature probe (Model EX363)

SPECIFICATIONS

Display Count

Basic Accuracy (DCV)

NCV Detector

DC/AC Voltage

DC/AC Current

DC/AC μA Current

Resistance

Capacitance

Frequency

Temperature (Type K)

Diode Test/Continuity

Dimensions/ Weight

EX360 EX363 EX365

6000

0.5%

Yes

0.1 mV to 1000 V

0.1 Ω to 40 M Ω

1 nF to 10 mF

6000

0.5%

Yes

0.1 mV to 1000 V

600 μA

0.1 Ω to 40 M

1 nF to 10 mF

Ω

6000

0.5%

Yes

0.1 mV to 1000 V

1 mA to 10 A

0.1 Ω to 40 M

1 nF to 10 mF

Ω

0.01 Hz to 100 kHz

Yes

0.01 Hz to 100 kHz 0.01 Hz to 100 kHz

-40 to 742°F (-40 to 394°C) —

Yes

6.5x3.2x1.7" (164x82x44 mm)/5.9 oz (450 g)

Yes

ORDERING

EX360

EX363

EX365

Electrical CAT IV True RMS Multimeter + NCV

HVAC CAT IV True RMS Multimeter + NCV

Industrial CAT IV True RMS Multimeter + NCV

Benefits of LoZ Function

ON ON ON OFF

ON ON

OFF

ON

OFF

ON

OFF

OFF No LoZ function – picks up reading from ghost voltages

LoZ function – prevents false readings from ghost voltages

8

Indicates products that are available with optional calibration traceable to NIST.

See pages 146-147 for a complete listing.

EX400 Series Professional Multimeters

EX400A

Series Professional Multimeters

EX410A

EX430A

Models with or without the built-in Infrared Thermometer, auto or manual ranging, True RMS or averaging

• Large backlit LCD display with easy-to-read 1" digits

• Type K thermometer built-in for temperature measurements

• Low current capability: measure down to 0.1 μA

• Input fuse protection and mis-connection warnings

• CAT III-600 V safety rating

• Complete with CAT III test leads, multi-position tilt stand and velcro strap for hanging, protective holster with test lead holder, bead wire temperature probe, and 9 V battery

Model EX410A (Manual Ranging)

• Averaging multimeter

• 2-year warranty

Model EX430A (Autoranging)

• True RMS for accurate AC measurements

• Relative function

• 3-year warranty

Model EX470A (Autoranging)

• Built-in non-contact Infrared (IR) Thermometer

• True RMS for accurate AC measurements

• Relative function

• 3-year warranty

EX470A

DMM+IR Thermometer

Built-in non-contact

IR Thermometer allows you to safely perform non-contact temperature scans.

SPECIFICATIONS EX410A EX430A EX470A

Display Count

Temperature (IR)

2000

Averaging/True RMS Averaging

Basic Accuracy (VDC) ±0.5%

AC Voltage 1 mV to 600 V

DC Voltage

AC Current

DC Current

Resistance

Capacitance

Frequency

Temperature (Type K)

Duty Cycle

Diode Test/Continuity

Dimensions/ Weight

4000

True RMS

±0.3%

0.1 mV to 600 V

4000

58 to 518°F (-50 to 270°C)

True RMS

±0.3%

0.1 mV to 600 V

0.1 mV to 600 V

0.1 μA to 10 A

0.1 μA to 10 A

0.1 Ω to 20 M Ω

0.1 mV to 600 V

0.1 μA to 10 A

0.1 μA to 10 A

0.1 Ω to 40 M Ω

0.01nF to 100μF

0.1 mV to 600 V

0.1 μA to 10 A

0.1 μA to 10 A

0.1 Ω to 40 M Ω

0.01 nF to 100 μF

— 0.001 Hz to 10 MHz 0.001 Hz to 10 MHz

-4 to 1382°F (-20 to 750°C) -4 to 1382°F (-20 to 750°C) -4 to 1382°F (-20 to 750°C)

Yes

0.1% to 99.9%

Yes

7.4x3.2x2" (187x81x50 mm)/0.75 lbs (342 g)

0.1% to 99.9%

Yes

Watch the

Video

www.extech.com/video

ORDERING

EX410A

EX430A

EX470A

TL810

TL803

TP200

HG500

Manual Ranging Multimeter

True RMS Autoranging Multimeter

True RMS Autoranging Multimeter + IR Thermometer

Electrical Test Lead Kit

Standard Test Leads

Type K Clamp Probe (212°F/100°C)

Magnetic Hanging Strap

Extech-exclusive Meters with Built-in IR Thermometer!

Our innovative design incorporates a built-in IR Thermometer. Look for the built-in IR Thermometer logo throughout this catalog.

Multimeters Clamp Meters Psychrometers Humidity Meters Moisture Meters Tachometers Air Flow Meters

For the name of your local stocking distributor, visit www.extech.com

9

EX500 Series CAT IV Waterproof Industrial Multimeters

EX500

CAT IV Heavy Duty True RMS Multimeters

EX505

EX520

EX530

Waterproof (IP67)/drop proof (6.5 ft/2 m) rugged design for heavy duty use

• True RMS for accurate AC measurements

• 1000 V input protection on all functions

• Dual sensitivity frequency functions; Diode open circuit voltage of 2.8 V DC

• Auto Power Off with disable feature

• CAT IV-600 V safety rating

• 3-year warranty

Model EX505

• 4,000 count backlit LCD

• 0.5% basic accuracy

• Data Hold, Relative, and 10 A max Current

Model EX520

• 6000 count—high resolution backlit LCD

• 0.09% basic accuracy

• Min/Max, Data Hold, Relative, and 20 A max Current

Model EX530

• 40,000 count—highest resolution backlit LCD

• 0.06% basic accuracy

• Min/Max, Data Hold, Relative, 20 A max Current, and Peak Hold (AC only)

Complete with double molded test leads, magnetic hanging strap, general purpose Type K bead wire temperature probe, soft case, and one 9 V battery

Watch the

Video

www.extech.com/video

SPECIFICATIONS EX505 EX520 EX530

Basic Accuracy

DC Voltage

±0.5%

0.1 mV to 1000 V DC

AC Voltage 0.1 mV to 1000 V AC

DC/AC Current

Resistance

Capacitance

0.1 μA to 10 A

0.1 Ω to 40 M Ω

0.01 nF to 100 μF

Frequency (electrical) 5 Hz to 1 kHz

±0.09%

0.1 mV to 1000 V DC

1 mV to 1000 V AC

0.1 μA to 20 A

0.1 Ω to 40 M Ω

0.01 nF to 1000 μF

10 Hz to 400 Hz

±0.06%

0.01 mV to 1000 V DC

0.01 mV to 1000 V AC

0.01 μA to 20 A

0.01 Ω to 40 M Ω

0.001 nF to 40 mF

40 Hz to 400 Hz

Frequency (electronic) 0.001 Hz to 10 MHz 0.001 Hz to 40 MHz 0.001 Hz to 100 MHz

Temperature (Type K) -4 to 1382°F/-20 to 750°C -4 to 1382°F/-20 to 750°C -4 to 1382°F/-20 to 750°C

Duty Cycle

Diode/Continuity

Dimensions/Weight

0.1 to 99.9%

Yes/Audible

0.1 to 99.9%

Yes/Audible

7.25x3.25x2.25" (184x83x57 mm)/12.3 oz (349 g)

0.1 to 99.9%

Yes/Audible

Waterproof (IP67) rugged double molded design for heavy duty application use

ORDERING

EX505

EX520

EX530

TL810

TL805

HG500

True RMS Industrial Multimeter (4000 count)

True RMS Industrial Multimeter (6000 count)

True RMS Industrial Multimeter (40,000 count)

Electrical Test Lead Kit

Double Injected Test Leads

Magnetic Hanging Strap

10

EX505-K

Heavy Duty Industrial Multimeter Kit

CAT IV Multimeter and AC Voltage Detector With 8 piece test lead kit

• Kit includes EX505 True RMS waterproof (IP67)/drop-proof Multimeter, DV25

Dual Range Non-contact AC Voltage Detector + Flashlight, TL808 8-piece

Professional Test Lead Kit, plus professional double-molded test leads, Type K thermocouple bead probe with banana input adaptor, and magnetic hanging strap

• Supplied in a soft carrying case that provides protection and organization for the meters and accessories

• Dimensions: 9.8x8x2" (248x203x51 mm); Weight: 1.2 lbs (544 g)

Model EX505: Industrial grade, CAT IV-600 V, 4000 count display, waterproof (IP67),

CE/UL listed, drop-proof, rugged multimeter with True RMS functions (see p. 10 )

Model DV25: Dual Range Non-Contact Voltage (NCV) Detector (24 to 1000 V AC/100 to 1000 V AC) + Flashlight with Audible/ Visual indication, and double-molded housing

CAT IV-1000 V, CE/UL (see p. 28 )

Model TL808: 8-Piece Professional Test Lead Kit with CAT III-1000 V rating

ORDERING

(VISIT WWW.EXTECH.COM FOR PRODUCT SPECIFICATIONS)

EX505-K Heavy Duty Industrial Multimeter Kit

Indicates products that are available with optional calibration traceable to NIST.

See pages 146-147 for a complete listing.

Bluetooth ® Wireless Datalogging Multimeter

MM750W

Wireless Datalogging CAT IV True RMS Multimeter

DAT12 included

Using the Wireless connectivity feature, Bluetooth ® datalogging module, and free app, you can transmit readings right to your iOS ® or Android ™ devices

Multimeter Features

• Wireless DMM function with Bluetooth Datalogging Module transmits readings to iOS and Android devices for remote viewing using the free app

• True RMS for accurate AC measurements

• Type K Temperature function

• Large backlit LCD display

• ±0.6% basic DCV accuracy

• Built-in Non-Contact AC Voltage Detector (NCV)

• AC μA function ideal for HVAC flame rod current measurement

• External clamp adapter input (1 mV=1 A; 600 A AC/DC max)

• MIN/MAX/DIF captures highest & lowest readings and the difference between them

• Relative Mode for Capacitance Zero and offset adjustment

• Data Hold freezes the reading on the display

• Auto Power Off with disable and low battery indicator

• CAT IV-600 V, CAT III-1000 V safety category

• 2 year warranty

• Complete with test leads, general purpose Type K bead wire temperature probe,

Wireless Datalogging Module (DAT12), 9 V battery, and soft case

Wireless Datalogging Features

• Bluetooth Datalogging Module (DAT12) can record over 15k readings and transmit them to a smart device

• Free ExView ® W-Series App, provides Wireless Data Streaming with real-time remote viewing of readings

• Adjustable sample rate and file size support most application needs

• Record data directly to phone or tablet

• Programmable High/Low audible alarms

• Export data in Excel ® format

• Share data files and snapshots directly from application

• Take snapshots of the measurement area with your connected smart phone or tablet camera to capture measurement-related images and to document date/time stamps and measurement data

Using the wireless feature, Bluetooth ® Datalogging

Module, and the free ExView ® W-Series App, you can transmit readings in real-time to your smart devices, store over 15k readings for wireless transfer to generate a report/data analysis, add notes and readings to photos taken from your smart device camera, and use your smart device as a 2nd display for easy viewing or sharing.

Download the Extech ExView ™ W-Series App available on App Store or Google Play. NOTE: iOS/

Android device not included.

Apple and the Apple logo are trademarks of Apple Inc., registered in the

U.S. and other countries. App Store is a service mark of Apple Inc.

Google Play and the Google Play logo are trademarks of Google LLC.

SPECIFICATIONS

AC Current

DC Current

AC μA Current

DC μA Current

Resistance

Capacitance

Frequency

Temperature (Type K)

Duty Cycle

Diode Test

Continuity

Datalogging (with DAT12)

Dimensions/Weight

RANGE

Display Count 6000

Non-Contact Voltage (NCV) >100 V AC

AC Voltage

DC Voltage

0.1 mV to 1000 V

0.1 mV to 1000 V

MAX RESOLUTION

0.1 mV

0.1 mV

BASIC ACCURACY

±0.6% of rdg ±3 digits

±0.6% of rdg ±2 digits

0.1 μA to 10.00 A

0.1 μA to 10.00 A

0.1 μA to 6000 μA

0.1 μA to 6000 μA

0.1 Ω to 60.00 M Ω

9.999 nF to 99.99 mF

9.999 Hz to 55.00 MHz

-40 to 1832°F

(-40 to 1000°C)

0.1 μA

0.1 μA

0.1 μA

0.1 μA

0.1 Ω

0.001 nF

0.001 MHz

±0.15% of rdg ±5 digits

±0.12% of rdg ±5 digits

±0.15% of rdg ±5 digits

±0.12% of rdg ±5 digits

±0.6% of rdg ±2 digits

±5% of rdg ±5 digits

±1.5% of rdg ±3 digits

±(2%+2°F) / ±(2%+2°C)

0.1 to 99.9%

3.000 V

Audible

15,360 data points

0.10%

0.001 V

±1.2% of rdg ±2 digits

±10% of rdg ±5 digits

7.4x3.8x2.2" (188x96x56 mm) / 14.6 oz (415 g) without battery

ORDERING

MM750W

TL810

TL803

DAT12

Wireless Datalogging CAT IV True RMS Multimeter

Test Lead Kit

Standard Test Leads

Replacement Bluetooth ® Wireless Datalogging Module

For the name of your local stocking distributor, visit www.extech.com

11

Combination Multimeters/Insulation Testers

MG320/MG325

CAT IV Insulation Tester/True RMS Multimeters

Combines a portable Insulation Tester with a CAT IV True RMS Multimeter

• 5 Test Voltage ranges up to 1000 V

• Polarization Index (PI) and Dielectric Absorption Ratio measurements (DAR)

• Low Resistance measurement with Zero function

• Programmable Timer feature sets the duration of test

• Comparison Mode allows user to set the Pass/

Fail values for insulation measurements

• Step Voltage (10% steps at 50% to 120% of range)

• Auto-discharge of voltage test signal

• Lock Power-On function for hands-free operation

• Manually store/recall up to 99 readings

• High voltage and overloa d indication

• Data Hold to freeze displayed reading

• Auto Power Off and low battery indication

• CAT IV-600 V safety category

• 2-year warranty

Model MG320

• Measures Insulation Resistance to 20 G

Ω

• Backlit 6,000 count display with analog bargraph

• Complete with test leads, alligator clip, 6 x AA batteries, and soft case

Model MG325

• Measures Insulation Resistance to 200 G

Ω

• Backlit 10,000 count display with analog bargraph

• View the Frequency (45 Hz ~ 400 Hz) of AC Voltage measurements

• Remote probe with built-in TEST button allows for quick on-spot testing

• LED high voltage and LCD overload indication

• Measures Leakage Current, Low Resistance, Capacitance, and Frequency

• Complete with remote probe, test leads, alligator clip, 6 x AA batteries, and soft case

SPECIFICATIONS

Insulation Resistance

MG320

50 M Ω , 100 M Ω , 200 M Ω , 500 M Ω ,

2000 M

Ω

, 1 G

Ω

, 10 G

Ω

, 20 G

Ω

MG325

50 M Ω , 100 M Ω , 200 M Ω , 500 M Ω ,

2000 M

Ω

, 1 G

Ω

, 10 G

Ω

, 20 G

Ω

, 50 G

Ω

,

100 G Ω , 200 G Ω

50 V, 100 V, 250 V, 500 V, 1000 V

600 V

Insulation Test Voltages 50 V, 100 V, 250 V, 500 V, 1000 V

AC/DC Voltage 600 V

Leakage Current

Resistance

Low Resistance

Capacitance

Frequency

Continuity

Dimensions/ Weight

20 k Ω

Audible

8.9x4.1x2.3" (225x103x59 mm)/1.5 lbs (0.7 kg)

2000 μA

10 M Ω

100 Ω

500 μF

1 kHZ

Audible

ORDERING

MG320

MG325

CAT IV Insulation Tester/True RMS Multimeter

CAT IV Insulation Tester/ True RMS Multimeter with Remote Test Probe

Checking voltage on a lathe and insulation test on pump motor

12

Indicates products that are available with optional calibration traceable to NIST.

See pages 146-147 for a complete listing.

Compact Multimeters and Pen Multimeter

DM220

CAT IV Pocket Multimeter + NCV

Autoranging DMM with 4000 count LCD display, NCV and built-in Flashlight

• Non-Contact Voltage detection identifies live circuits

• Rugged double molded housing; CAT IV-600 V, CAT III-1000 V safety rating

Includes test leads and two AAA batteries; 2-year warranty

SPECIFICATIONS

DC/AC Voltage

DC/AC Current

NC Voltage

Resistance

Frequency

Capacitance

Duty Cycle

Diode/Continuity

Dimensions/Weight

RANGE

600 V

200 mA

100 to 600 VAC

40 M Ω

10 kHz

200 μF

MAX RESOLUTION

0.1 mV DC/1 mV AC

0.1 μA

0.1 Ω

0.001 Hz

0.001 nF

0.5 to 99%

Yes/Audible

0.5%

4.72x2.2x1.6" (120x55x540 mm)/5.12 oz (145 g)

BASIC ACCURACY (%RDG)

±0.8% DC/±1.5% AC

±2.0% DC/±2.5% AC

±0.8%

±2.0%

±5.0%

±(2.0% reading + 5 digits)

ORDERING

DM220 CAT IV Pocket Multimeter + NCV

MN35/MN36

Digital Mini Multimeters

Autoranging or Manual ranging multimeters with Temperature function

• Large easy to read digital display

MN35 (Manual Ranging/ 8 Functions)

• 1.5 V and 9 V Battery test

MN36 (Autoranging/ 10 Functions)

• AC Current, Capacitance and Frequency measurements

Includes holster with stand,

Type K bead wire probe, battery, and test leads; 2-year warranty

SPECIFICATIONS

DC Voltage

AC Voltage

DC Current

AC Current

Resistance

Capacitance

Frequency

Temperature

Battery Test

Dimensions/Wt

MN35 BASIC ACCURACY MN36

600 V (0.1 mV)

600 V (0.1 V)

10 A (0.1 mA)

20 M

Ω (0.1 μ Ω )

-4 to 1400°F (1°)

-20 to 750°C

±0.5%

±1.2%

±1.5%

±0.8%

±(1%+4°)

600 V (0.1 mV)

600 V (0.1 V)

10 A (0.1 μA)

10 A (0.1 μA)

40 M Ω (0.1 μ Ω )

100 μF (0.001 nF)

5 MHz (0.01 Hz)

-4 to 1400°F (1°)

-20 to 750°C

9 V and 1.5 V

5.43x2.83x1.5" (138x72x38 mm)/5.4 oz (153 g)

BASIC ACCURACY

±0.5%

±1.2%

±1.2%

±1.5%

±1.2%

±3.0%

±1.0%

±(1%+4°)

ORDERING

MN35

MN36

Manual Ranging Mini Digital Multimeter

Autoranging Mini Digital Multimeter

381676A

Pen DMM with Non-Contact Voltage Detector

Autoranging multimeter with non-contact voltage detection

• Autoranging with Data Hold, Range Hold, and Maximum Hold features

• CAT III-600 V; Auto power off, overload and low battery indication

• 2-year warranty

Includes test leads, two alligator clips, two 1.5 V

AAA batteries, and soft case

SPECIFICATIONS

Non-contact Voltage

AC/DC Voltage

AC/DC Current

Resistance ( Ω )

Logic Test

Diode/Continuity

Dimensions/Weight

RANGE MAX RESOLUTION BASIC ACCURACY

>110 V AC

200 mV, 2, 20, 200, 600 V 0.1 mV AC: ±0.8%; DC: 0.7%

20 mA, 200 mA 0.01 μA

200, 2 k, 20 k, 200 k, 2 M, 20 M Ω 0.1

Ω

AC: ±2%; DC: 0.1.5%

±0.8%

0 to 1.5 V (Green LED), 1.5 to 3.5 V (LED off), 3.5 to 5 V (Red LED)

Yes/Audible

8.2x1.5x1.1" (208x38x29 mm)/4.6 oz (129 g)

ORDERING

381676A Pen DMM with Non-Contact Voltage Detector

For the name of your local stocking distributor, visit www.extech.com

13

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Built-in non-contact voltage detector for quick and easy voltage detection
  • Large, easy-to-read 1" digits for clear visibility
  • CAT III-600 V, CAT II-1000 V safety rating for added protection
  • 2-year warranty for peace of mind
  • Complete with stand, test leads, protective holster, batteries, and general purpose Type K bead wire temperature probe (EX330 only)

Related manuals

Frequently Answers and Questions

What is the basic accuracy of the EX310?
The basic accuracy of the EX310 is 0.50%.
What is the maximum voltage that the EX330 can measure?
The EX330 can measure up to 600 V AC and DC.
What type of temperature probe is included with the EX330?
The EX330 includes a general purpose Type K bead wire temperature probe.
What is the difference between the EX310 and the EX330?
The EX310 is a manual ranging multimeter, while the EX330 is an autoranging multimeter. The EX330 also has additional features such as data hold, auto power off, and advanced functions like Type K temperature, capacitance, and frequency measurements.
How long is the warranty on the EX300 Series multimeters?
The EX300 Series multimeters come with a 2-year warranty.

advertisement