Specifications
MODEL
RH-42
RH-42
Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision.
Royal Hearth 42
Wood-burning Fireplace
FRONT WIDTH BACK WIDTH HEIGHT DEPTH
Actual Framing Actual Framing Actual Framing Actual Framing
47 48 29-3/4 48 39-1/2 39-3/4 21-3/8 21-1/2
FIREBOX OPENING
42 X 18-3/4
29-3/4" [7564]
14-7/8"
[378]
7-3/8"
[187]
21-3/8"
[543]
47" [1194]
Top View
21"
[533]
18-3/4"
[476]
7-1/2"
[191]
21"
[533]
14-1/8"
[359]
7-1/2"
[191]
42" [1067]
Front View
Outside
Air
Gas
Knockout
7-1/2"
[191]
Left Side View
9-1/4"
[235]
Additional information can be found online at www.heatnglo.com or www.fireplaces.com
39-1/2"
[1003]
Gas
Knockout
7-1/2"
[191]
Right Side View
9-1/4"
[235]
APPLIANCE LOCATION
17"
[429]
52-1/4" [1327]
37-1/4"
[946]
48"
[1219]
73-7/8"
[1876]
48" [1219]
56" [1422] or projecting into a garage fireplace opening wall
21-1/2"
[546] divider
65-1/2"
48"
[1664]
[1219] minimum
MANTEL PROJECTIONS
Along a wall
56" [1422]
48" [1219]
5/8" [16] all configurations
21-1/2"
[546]
FRAMING DIMENSIONS
2" [51] minimum air space clearance from chimney
Header MUST NOT be notched!
*39-3/4"
[1010]
48"
[1219]
8"
[203]
21-1/2"
[546]
* If interior of chase is drywalled, add thickness to
** Adjust header height for raised floor under fireplace
Extra space needed for outside air connection.
See install manual for other details.
CLEARANCE TO COMBUSTIBLES
Combustible Wall Combustible
Decorative Facing
7 ft [2134] minimum base of fireplace to ceiling
2 x 4 stud wall
Standoffs
12"
[305]
12" [305]
Seal joint with non-combustible sealant
6" [152] minimum
Measured from top of fireplace opening
Non-combustible
Decorative Facing such as:
Steel, iron, brick, tile, concrete, slate, glass, plasters.
MANTEL LEG/WALL PROJECTIONS
FLUSH
FRONT
BRICK
FRONT
4"
[102]
11-1/4"
[286]
42" [1067]
39° angle 9-3/4"
[248]
50° angle
47" [1194]
12"
[305]
HEARTH EXTENSIONS
4" [102] minimum between bottom of fireplace opening and surface of hearth extension
12"
[305]
20"
[508]
12"
[305]
Storm Collar
Roof Flashing
(attic)
(insulation)
2" [51] minimum
Ceiling Firestop
(roof)
Shaded areas represents
2" [51] minimum air space clearance required around pipe.
Insulation
Shield
(ceiling)
(ceiling)
Must have 2" [51] minimum clearance to header
0" to level of standoffs
1/2" [13] to back & sides of appliance
HEARTH EXTENSION CONSTRUCTION
1/2" Micore Hearth
Extension (or
Continuous, noncombustible sealant
Tile, stone or other non-combustible material
Fireplace
Opening
4" [102] minimum
Floor constructed of wood or other combustible material
2" [51] of the Protective
Metal Hearth Strip is required under the front of the fireplace
PRODUCT LISTING CODES
US
CAN
UL 127
ULC-S610
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Additional information can be found online at www.heatnglo.com
A brand of Hearth & Home Technologies™ Inc.
Lakeville, MN Phone: (800) 927-6841
Web: www.heatnglo.com
WS/HNG/RH-42_0316