- Home
- Home security & automation
- Security device components
- Ascon tecnologic
- SAT1
- Installation manual
Ascon Tecnologic SAT1 Open case customizable Multifunction Controller Installation Manual
Add to My manuals8 Pages
advertisement
mod.
SAT1
23/10 - Code: ISTR_ I _SAT1_E_00_--
Installation
Manual
Integrated system,
CPU module with on-board I/O
SAT1
model
Ascon Tecnologic S.r.l. a socio unico via Indipendenza 56,
27029 - Vigevano (PV)
Tel.: +39 0381 69871,
Fax: +39 0381 698730 www.ascontecnologic.com
E
Contents
- General description
- Accessories
- Installation
- Electrical connections
- Electric safety
1
21 20
General description
19 10 11 6 5
15
14
13
12
7
8
9
Dimensions (mm)
Installation
Operating conditions
1 X5
1 X12
1 X4
1 X8
X2 1
203
X1
70
Environmental condition
B
Operating conditions
T
%Rh
Temperature
0...+50°C
Umidity:
5... 95% Rh non condensing
Suggestion
T Temperature
> 50°C
Use forced ventilation
Special conditions
%Rh
> 95% RH Warm up
Forbidden conditions
P
C
Conducting atmosphere
Corrosive atmosphere
Use filter
E Explosive atmosphere
18 17 16 4 3 2
1 DIN RAIL 35 x 7.5 (EN50022);
2 X1 : 2 poles plug to connect the power supply;
3 X2 : 5 poles plug to connect DI5... DI8 High Voltage Digital Inputs;
4 X3 : 4 poles plug to connect OP9... OP11 SPST-NO 5 A output relays;
5 X4 : 6 poles plug to connect DI1... DI4 Digital Inputs;
6 X5 : 5 poles plug to connect OP4, OP5 (SPST-NO 5 A) and OP6 (SPDT 8 A) output relays;
7 X6 : 5 poles plug to connect AO1... AO4 analogue outputs (0/4... 20 mA,
PWM and Hz);
8 X7 : 5 poles plug to connect CN1... CN4 High speed Digital Inputs;
9 X8 : 10 poles plug to connect AI1... AI4 Analogue Inputs (mA, TC, PT100,
PT1000, NTC)
10 X10 : USB type A receptacle to connect a flash drive;
11 X11 : RJ45 plug to connect the Ethernet TCP/IP network for programming purposes or for the MODBUS through the TCP port;
12 X12 : 3 poles plug to connect COM1 serial port (RS485);
13 4 switches to configure the serial port parameters;
14 Reset button;
15 Status/diagnostic LEDs: COM1 (green, COM1 traffic), USB (white, USB activity), MSG (red, message), RUN (green, program status run/stop),
PWR (blue, power supply ON);
16 X13 : 3 poles plug to connect OP3 (SPDT 16 A) output relay;
17 X14 : 3 poles plug to connect OP2 (SPDT 16 A or SPST-NO 30 A) output relay;
18 X15 : 3 poles plug to connect OP1 (SPDT 16 A or SPST-NO 30 A) output relay;
19 X16 : 4 poles plug to connect OP14... OP16 SPST-NO 5 A output relays;
20 X17 : 4 poles plug to connect OP12... OP13 (SPST-NO 5 A output relays or
12 V outputs for SSR drives or 4 A/250 Vdc SSR outputs);
21 X18 : 4 poles plug to connect OP7... OP8 (SPST-NO 5 A output relays or
12 V outputs for SSR drives or 4 A/250 Vdc SSR outputs).
Mounting position
- Mount the module vertically;
- In order to help the ventilation flow of air, respect the distances between modules and walls or other modules.
Mounting position (mm) min. 80 min. 60
55 min. 100
Mounting/removing the modules on/from the DIN rail
1 C lip the upper part of the module to the rail ;
2 Rotate the module downwards until the lower hook engages the DIN rail ;
3 Switch OFF the Power Supply
With two fingers, press in the area indicated by the arrow until the hook is freed from the DIN guide ;
4 Turn and lift the module upwards to remove the CPU from the DIN rail.
Mounting the module
1
2
Removing the module
Disposal
The appliance (or the product) must be disposed of separately in compliance with the local standards in force on waste disposal.
Accessories
24 Vdc Power supply
APS2ALEDR12024 (120 W, 5.0 A),
APS2ALNDR75-24 (75 W, 3.2 A),
APS2ALMDR20-24 (20 W, 1.0 A)
Screw Terminal Blocks
APS2/??
3
4
X18 X17 X16
X10
X11
X6 X7
Electrical connections
X5
Terminals connections and plugs
X12
X8
X4
Conn. Label
X1
1
2
X2
24 Vac/dc
Signals
Power Supply
1 Neutral (high voltage input)
2 DI5 Line (high voltage input)
3 DI6 Line (high voltage input)
X3
4 DI7 Line (high voltage input)
5 DI8 Line (high voltage input)
1 OP9 SPST-NO relay
2 OP10 SPST-NO relay
3 OP11 SPST-NO relay
4 Common pole of the relays
X2 X1
Conn. Label Signals
1 RS485 D+ connection
X12
X13
2 RS485 D connection
3 RS485 Ground connection
1 NC pole of OP3 relay
2 Common pole of OP3
3 NO pole of OP3 relay
X14
1
NC pole of OP2 SPDT relay.
Not connected for SPST-NO
30 A relay
2 Common pole of OP2
3
NO pole of OP2 relay (SPDT
16 A or SPST-NO 30 A)
X15 X14 X13 X3
X15
X18
X15
X18
X14
X17
X14
X17
X13
X16
X13
X6
X16
X10
X6
X7
X3
X10
X11
X3
X7
Description
Flexible cable section:
L
Stripped wire
Plugs of all terminals
0.2... 2.5 mm ² (AWG24... AWG12)
Screw: 7mm Spring: 10mm
Flat blade screwdriver 0.6 x 3.5 mm 0.4 x 2.5 mm
Tightening torque 0.5... 0.6 Nm -
X5 X4
- The green terminals are male connectors (pitch 3.5 or 5 mm), the corresponding female plugs are snap-on connectors with screw or spring terminals for connecting the wires. The connectors terminals are labelled;
- Made with self extinguishing material as required by UL94 V0 standard;
- Overvoltage cathegory/pollution degree II/2;
- Max. load current/section 8 A/2.5mm
- Test pulse voltage: 4 kVp.
² at 65°C;
A
A
Make sure that the overall current absorption (modules and field devices) matches the power supply;
In order to avoid excessive voltage drops, install the most power consuming modules closer to the power supply.
Conn. Label
X4
1 Ground
2 DI1
3 DI2
4 DI3
5 DI4
X5
X6
Signals
6 24 V for Digital Inputs
1 Common pole of the relays
2 NC pole of OP6 relay
3 NO pole of OP6 relay
4 NO pole of OP5 relayv
5 NO pole of OP4 relay
1 AO4 Positive pole
2 AO3 Positive pole
3 AO2 Positive pole
4 AO1 Positive pole
5 Common pole of the AOs
Conn. Label
X15
X16
X17
1
Signals
NC pole of OP2 SPDT relay.
Not connected for SPST-NO
30 A relay
2 Common pole of OP2
3
NO pole of OP2 relay (SPDT
16 A or SPST-NO 30 A)
1 NO pole of OP14 relay
2 NO pole of OP15 relay
3 NO pole of OP16 relay
4 Common pole of the relays
1
2
OP12 5 A relay common
Negative pole of OP12 SSR
Pole of OP12 SSR Drive
OP12 5 A relay NO pole
Positive pole of OP12 SSR
Pole of OP12 SSR Drive
X11
X2
X5
X8
Power supply (X1 connector)
X4
- Connector : 24 Vac/dc
(–10...+10%), 15W max.;
- The power supply terminals
( X1-1 and X1-2 ) are not polarized as the CPU acceps both the 24 Vac
X18 and 24 Vdc.
X17
X12
Vac/Vdc
X1 Power Supply connector
Conn. Label Signals
1 CN4 Positive pole
2 CN3 Positive pole
X7
X16
3 CN2 Positive pole
4 CN1 Positive pole
5 Ground
1 Ground
2 Transmitters PWS (12 V)
X8
3 AI1 Negative pole
4 AI1 Positive pole (TC)
5 AI2 Negative pole
6
7
X10
Positive pole (TC)
Negative pole
8 AI3 X11
9 AI4 Negative pole
10 AI4 Positive pole (TC)
X10 USB USB Type A port
X11 ETH RJ45 Ethernet port
X5
Conn. Label
X17
(cnt.)
3
4
1
2
3
4
Signals
OP13 5 A relay common
Negative pole of OP13 SSR
Pole of OP13 SSR Drive
OP13 5 A relay NO pole
Positive pole of OP13 SSR
Pole of OP13 SSR Drive
X4
5 A relay common
Negative pole of OP7 SSR
Pole of OP7 SSR Drive
OP7 5 A relay NO pole
Positive pole of OP7 SSR
Pole of OP7 SSR Drive
OP8 5 A relay common
Negative pole of OP8 SSR
Pole of OP8 SSR Drive
OP8 5 A relay NO pole
Positive pole of OP8 SSR
Pole of OP8 SSR Drive
High Voltage (mains) Digital Inputs (X2 connector)
X2 1
X8
X1
X15
- Connector X2 : DI5... DI8 High
Voltage Digital Inputs;
- Terminal 1 (CV) is the common (neutral) terminal of the 100... 240 Vac digital inputs DI5... DI8;
- Respect the connection shown, the common terminal is shared by the
4 digital inputs.
k
X14 X13
High voltage inputs, remove the mains and pay extreme attention while performing these input connections.
Line Neutral
X2 High voltage
Digital Inputs
X6
Digital outputs: SPST-NO Relays (X3 connector)
- Connector X3 : OP9... OP11
SPST-NO relays outputs;
X7
- Insulation: 2500 V beween channel and Power Supply and between channel and main electronics.
1
X3 - SPST-NO 5A relay terminals
X2 X1
X18 X17 X16 X5 X4
X10
X11
X12
X15
X18
X15
X18
X14
X17
X14
X17
X13
X18
X15
X16
X15
X5
X18
DI1... DI4 Digital Inputs (X4 connector)
X4 - DI1... DI4 terminals
- Connector X4 : DI1... DI4 digital inputs;
- Insulation: 800 V between channel ad Power Supply.
X6 X7
X17
X17
X14
1 X4
X13
X10
X3
X11
X5
X16
X2
X12
AI1... AI4 Analogue Input (X8 connector)
TC
X8
X8
X4
X10
X1
X11
- Connector X8 : AI1... AI4 digital inputs;
- Respect the polarity shown;
- Pay attention to correctly connect the power source (12 Vdc);
- Type: 0/4... 20 mA, TC (J, K, L, N, R,
X5
- Resolution: 16 bit;
X4
- Accuracy: 0.5% of span (linear inputs),
0.5% (temp.) ±1°C (cold junction);
- Input impedance: 120 k Ω (V),
<200 Ω (mA).
X12 m Verify the option ordered for
AI1... AI4 Inputs.
X18
X15
X13
X10 X12
TC TC TC TC
X8 Analogue input terminals
X6
X16
X17
X14
X3
X6
X11
X7
X17
X5 - OP4... OP6 relay output terminals
X16
X18
X15
OP4... OP6 Digital Outputs (X5 connector)
X8
X14
X17
- Connectors X5 :
2 SPST NO relays (OP4, OP5) +
1 SPDT relay (OP6);
X5 loads);
X6
X4
X7
X17 and Power Supply and between
X13
X15 X12 X14
X3
1
X10
X2 X1
X11
X13
X5
1
X16
Pt100/Pt1000
2 wires input
X6
X8
X4
X2
X7
X10 X12
X11
X16
X3
X7
X13
+
X15
+
1
AO1... AO4 Analogue Output (X6 connector)
+
X6
X2
X14
X11
G
X6 - AO1... AO4 terminals
X3
X8
X5
X1
- Connector X6 : AO1... AO4 analoue outputs;
X8
- For the analogue output, respect the polarity shown;
X4 X6 X7 and Hz;
X2 Ω ;
- Resolution: 16 bit; m
X1
- Accuracy: 0.5%;
- Insulation:
X14
X3
800 V Channel-Power supply,
50 V channel-main electronics;
These outputs are ordered in pairs (AO1/AO2 and AO3/AO4).
Verify the option ordered for
AO1/AO2 and AO3/AO4 Inputs.
X13
X12 X10
A A A A
X11
B b
B b
B b
B b
X8 Analogue input terminals
1
X2
0/4... 20 mA active transmitter
X6 X7
X8
+
-
+
-
+
-
+
-
X8 Analogue input terminals
X14 X13
X6
Special (High Speed) Digital Inputs (X7 connector)
1
X3
X7
24 Vdc
+
X7 - DI1... DI4 terminals
X2
In the drawing are connected only 2 counter inputs as an example (CN2 and CN4).
Frequency meter input:
- The channels can manage up to 10 kHz signals having a duty-cycle that guarantees minimum of ON signal
X18 X17
Impulse counter input:
- The minimum time of an impluse must be 20 ms;
Digital input:
- The input circuit is internally closed to System Ground.
m Verify the option ordered for
CN1... CN4 Inputs.
X16
X10
X11
X5
1
X2
NPT inputs
X8
X8
X4
X8 Analogue input terminals
X5
0/4... 20 mA 2 wires passive Transmitter
X8
1 X8
X2
X12
X12
X4
X1
X1
X8 Analogue input terminals
USB port connector
X10 - USB type A connector
- USB type A receptacle ( X10 ) to connect a flash drive (system files upload or data logging download).
USB type A
X15 X14 X13
X6 X7
X3
X8
X2 X1
X18 X17 X16 X5 X4
X10
X11
X12
X15
X18
X14
X14
X17
X17
X15
X18
X13
X16
X13
X14
X16
X17 X16
Ethernet connector (X11 connector)
X11 - Ethernet RJ45 connector
Status/traffic LEDs
X5
- Connector X11 : The Ethernet connection is made through a standard
J45 connector;
- The 2 green LEDs near the Ethernet connector show the port status and the communication traffic.
X4
OP1 Digital Output: SPST-NO 30 A or SPDT 16 A Relay (X14 connector)
X18
First option:
SPST-NO 30A X17
- Connector X14 : OP2 first option
SPST-NO relay output.
- Rate: 30 A (for resistive loads).
- Insulation: 2500 V beween channel
X6 m
X16
OP2 output.
X10 X12
X15 X13
X10
X3
X11
OP2 X11
X14 - Configurable relay terminals
X10
X13
X11
X12 - RS485 connector
X6
X5
D+ D- GND
1 X12
X3
Serial Communications Port (X12 connector)
X7
X12
X4
POL+ POL- NONE TERM
X2
- Connector X12 : RS485 port to connect a fieldbus network using the
Modbus protocol (master/slave) or serial ASCII;
- The line settings can be configured using the specific DIP switches:
SW Description
1 Line polarization Pull-Up
Default
OFF
OFF 2 X1
3 Not used
4 110 Ω line termination OFF
DIP switch settings
X15
X18
OP2
Second option:
SPDT 16A
- Connector X14 : OP2 second option
SPDT relay output.
- Rate: 16 A (for resistive loads).
- Insulation: 2500 V beween channel
X6
X17
X13 m Verify the option ordered for
OP2 output.
X16
X3
X10
DIP switches
- Insulation from other electronics:
1.6 kV.
SPDT 16A
X14 - Configurable relay terminals
X11
X5
X2
X12
X2
X5
X8
X4
X8
X12
X1
X1
X4
X6
X10
X6
X18
X3
X11
X7
X7
X15
X3
X14
X17
X5
Sytem Pushbutton and Status LEDs
Status LEDs
X2
X8
X16
X4
System pushbutton
X1
- The 5 Status LEDs are:
COM (green), USB (white),
MSG (RED), RUN (green) and
PWR (blue).
- The meaning of the various LEDs behaviours are fully described in the “ SAT1 User Manual ”.
X4 m The system pushbutton performs different operations accorndingly to the system status but does not restart the CPU or
X10
X12
X11
OP2 Digital output: SPST-NO 30 A or SPDT 16 A Relay (X15 connector)
First option:
X17
- Connector X15 : OP1 first option
SPST-NO relay output.
- Rate: 30 A (for resistive loads).
- Insulation: 2500 V beween channel and Power Supply and between
X16 m Verify the option ordered for
OP1 output.
X7
OP1
X14 X13
X10
X3
X11
X15 - Configurable relay terminals
X2
Digital Output: SPDT 16 A Relay (X13 connector)
X8
X6
X3
- Connector X13 : OP3 SPDT relay output;
- Rate: 16 A (for resistive loads);
X7 channel and main electronics.
Digital output: SPDT 16 A Relay
(X13 connector)
X2
X1
OP3
X1
Second option:
SPDT 16A
OP1
X14
- Connector X15 : OP1 second option
SPDT relay output.
- Rate: 16 A (for resistive loads).
- Insulation: 2500 V beween channel
X7 m Verify the option ordered for
OP1 output.
X13 X3
X13 - SPDT 16A relay terminals
SPDT 16A
X15 - Configurable relay terminals
X5
X2
X12
X2
X8
X4
X8
X1
X1
X15
X18
X14
X18
X17
Digital outputs: SPST Relays (X16 connector)
X16 - SPST-NO 5A relay terminals
- Connector X16 : OP14... OP16
SPST-NO relays outputs;
- Rate: 5 A (for resistive loads);
- Insulation: 2500 V beween channel and Power Supply and between channel and main electronics.
1
X5 X4
X10
X11
X12
Digital outputs: Configurable Outputs (X18 connector)
X18 - Configurable output terminals
1
X17
- Connector X18 : OP7, OP8 first option 2 relays outputs;
Relays:
- 2 SPST-NO relays;
- Rate: 5 A (for resistive loads);
- Insulation: 2500 V beween channel and Power Supply and between channel and main electronics.
m
First option:
2 SPST-NO 5A
X10
X11
Digital outputs: Configurable Outputs (X17 connector)
X17 - Configurable output terminals
- Connector X17 : OP12, OP13 first option 2 relays outputs;
Relays:
- 2 SPST-NO relays;
- Rate: 5 A (for resistive loads);
X6 X7
1
X16 and Power Supply and between channel and main electronics.
m Verify the option ordered for
OP12 and OP13 outputs.
X13
First option:
2 SPST-NO 5A
X3 X2 X1
X10 X12
X11
OP7
X18 - Configurable output terminals
LOAD
SSR
LOAD
SSR
OP8
+ +
X4
1
X15
12VDC for SSR
X14
X17
- Connector X18 : OP7, OP8 second option: 2 x 12 Vdc for SSR ;
SSR drives:
- Voltage output 0/12 Vdc;
- Respect the polarity shown;
- Outputs not isolated.
m Verify the option ordered for
X7
X16
X13
X10
X3
X11
X18
X15
X17 - Configurable output terminals
LOAD
SSR
LOAD
SSR
OP12 OP13
+ +
X14
1
Second option:
12VDC for SSR
X13
X16
- Connector X17 : OP12, OP13 second option: 2 x 12 Vdc for SSR .
SSR drives:
- Voltage output 0/12 Vdc;
- Respect the polarity shown;
- Outputs not isolated.
Verify the option ordered for
X10
X3
X5
X2
X12
OP7
X18 - Configurable output terminals
LOAD LOAD
Fuse Fuse
NO NO
OP8
X8
X4
1
X15
X1
SSR 4A/250V
X14
X11
X17
- Connector X18 : OP12, OP13 third option: SSR relays .
SSR:
- Rate: 4 A, 250 Vac;
- Zero Crossing Function;
- Insulation: 2500 V between channe-
X7 m
X6
Verify the option ordered for
OP12 and OP13 outputs.
X16
X13 X3
X10
X11
X18
X15
X17 - Configurable output terminals
LOAD LOAD
Fuse Fuse
OP12
NO NO
OP13
1
X14
Third option:
SSR 4A/250V
X13
X16
- Connector X17 : OP12, OP13 third option: SSR relays .
SSR:
- Rate: 4 A, 250 Vac;
- Zero Crossing Function;
- Insulation: 2500 V between channe-
X6 m
X7
Verify the option ordered for
OP12 and OP13 outputs.
X5
X3 X2
X10 X12
X11
X8
X4
X14 X13
X6
X3
X7
X5
X5
X2
X12
X8
X4
X1
X2
X12
X8
X4
X5
X2
X12
X8
X4
X1
X1
X15 X14 X13
X6 X7
X3
X8
X2 X1
SUGGESTED WIRES ROUTING
AI and DO cables
100
X18 X17 X16
X10
X11
X5 X4
X12
100
Power cables
X15 X14 X13
X6 X7
X3
X8
X1
100
Output cables
100
AI and DI cables
A Despite the fact that the instrument has been designed to work in an harsh and noisy environment, it is strongly recommended to follow the following suggestions.
All the wiring must comply with the local regulations.
The supply wiring should be routed away from the power cables. Avoid to use electromagnetic contactors, power relays and high power motors nearby.
Avoid power units nearby, especially if controlled in phase angle. Keep the low level sensor input wires away from the power lines and the output cables.
Power lines and output cables must also be at 100 mm (min.) away from the CPU.
If this is not achievable, use shielded cables on the sensor input, with the shield connected to earth.
A
Warning!
Whenever a failure or a malfunction of the device may cause dangerous situations for persons, things or animals, please remember that the plant must be equipped with additional devices which will guarantee safety.
How to Order
SAT1 = CPU of the Programmable Logic Controller with 24 Vac/Vdc Power Supply
AI1: Analogue Input 1 Pre-Configured
A = mA
C = Pt100
M = PT1000
N = NTC
T = TC
AI2: Analogue Input 2 Pre-Configured
A = mA
C = Pt100
M = PT1000
N = NTC
T = TC
AI3: Analogue Input 3 Pre-Configured
A = mA
C = Pt100
M = PT1000
N = NTC
T = TC
AI4: Analogue Input 4 Pre-Configured
A = mA
C = Pt100
M = PT1000
N = NTC
T = TC
AO1O2: Analogue Outputs 1 and 2
= Not provided
A = mA Outputs
D = Digital Outputs
F = PWM/Frequency Outputs
V = Voltage Outputs
AO3O4: Analogue Outputs 3 and 4
= Not provided
A = mA Outputs
D = Digital Outputs
F = PWM/Frequency Outputs
V = Voltage Outputs
DIGFI: High Speed Digital Inputs CN1... CN4
= Not provided
T = 4 High Speed Digital Inputs
ID: Free of Voltage Digital Inputs DI1... DI4
= Not provided
L = 4 Free of Voltage Digital Inputs
DIGVI: Main Voltage Digital Inputs DI5... DI8
= Not provided
V = 4 Main Voltage Digital Inputs
OO1: Digital Output OP1
F = Relay SPST-NO 40 A (faston)
H = Relay SPST-NO 30 A
S = Relay SPDT 16 A
OO2: Digital Output OP2
F = Relay SPST-NO 40 A (faston)
H = Relay SPST-NO 30 A
S = Relay SPDT 16 A
OO3: Digital Output OP3
S = Relay SPDT 16 A
OO456: Digital Outputs OP4... OP6
R = 2 relays SPST-NO 16 A + 1 relay SPDT 8 A
OO78: Digital Outputs OP7... OP8
O = 2 digital outputs 12 VDC for SSR drive
Q = 2 SSR digital outputs
R = 2 relays SPST-NO 5 A
OO9AB: Digital Outputs OP8... OP11
= Not provided
R = 3 relays SPST-NO 5 A
OOCD: Digital Outputs OP12 and OP13
O = 2 digital outputs 12 VDC for SSR drive
Q = 2 SSR digital outputs
R = 2 relays SPST-NO 5 A
OOEFG: Digital Outputs OP14... OP16
R = 3 relays SPST-NO 5 A
SCM: Serial Communications Port
= Not provided
I = Insulated RS485
S = Not Insulated RS485
SAT1
Connector map m SAT1 is a compex instrument with a very limited space for the connection labels.
Refer to the image that follows to identify each connector and find the position of terminal 1.
All the connections previously described are based on these 2 details
advertisement
Related manuals
advertisement