advertisement
Woodbridge Fireplace Inc.
OUTDOOR FIRE FEATURE
IN ENCLOSURE
O W N E R ’ S O P E R A T I O N A N D I N S T A L L A T I O N M A N U A L
We recommend that our products be installed and serviced by professionals who are certified in the U.S. by NFI (National Fireplace Institute).
Report # 0401GF002S
Complies with ANS Z21.97
.
CSA 2.41-201
7
"Outdoor Decorative Gas Appliances",
C S A 2.17-20 17 "Gas
-
Fired Appliances for Use at High Altitudes"
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space as a camper, tent, car or home .
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage.
Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
DANGER
If you smell gas:
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department.
WARNING:
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other ap p liance.
A
propane cylinder not connected for use shall not be stored in the vicinity of this or any other ap p liance.
For Outdoor Use Only
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
Version française de ce manuel est disponible à partir du site WEB : www.woodbridge
dealer .com
French version of this Owners Manual is available at www.woodbridgedealer.com
SAFETY
INFORMATION
WARNING: Any change to this appliance or its controls can be dangerous.
WARNINGS
1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate.
IMPORTANT:
should be inspected before use and at least annually by a quilified service person.
More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners and circulating air passageways of the appliance be kept clean.
2
2. When an appliance is for con-
nection to a fixed piping system,
the installation must conform
with local codes, or in the ab-
sence of local codes with the
National Fuel Gas Code, ANSI
Z223.1/NFPA 54 , or I nterna ti onal Fuel Gas Code , Natural
Gas and Propane Installation
Code, CSA B149.1
, or Pro-
pane Storage and Handling
Code, B149.2
, as applicable.
DANGER: Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the Fire - place may not be working properly.
Get fresh air at once! Have the
Fire place serviced.
Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade.
Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this appliance.
3. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
4. Do not burn solid fuel in the fireplace after installing the appliance. Do not use this appliance to cook food or burn paper or other objects.
5.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
6.
Clothing or other flammable materials should not be hung from the appliance, or placed on or near the app liance.
7.
Young children should be carefully supervised when they are in the area of the appliance.
8. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the trical Code, or the Canadian Electrical
Code, CSA C22.1, if applicable.
National Elec-
ANSI/NFPA 70
9.
Do not use appliance if any part has been under water.
Imm ediat ely call a qualif ied service techn ician to inspect the room appliance and to replace any part of the system and any gas control which has been under water.
10. Inspect the burner before each use of Outdoor Fire Feature .
The burner must be replaced prior to the appliance being put into operation if it is evident that the burner is damaged.
Please refer to "Illustrated parts List" for the replacement burner part number.
11. Turn the appliance off and let cool before servicing, installling, or repairing. Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance. Only a qualified service person should install, service, or repair appliance.
HIGH ALTITUDE
INSTALLATIONS:
The appliance is rated for installations up to 4500’ (1372 m) above sea level. Above 4500’ the appliance must be de- rated at the factory for the appropriate altitude.
LOCAL CODES
Install and use Outdoor Fire place
with care the
.
National Fuel Gas Code ANSI
In absence of local codes,
use the latest edition of The
Z223.1/NFPA54 available from:
* American National Standards
Institute, Inc., 1430
Broadway, New York,
NY 10018
* National Fire Protection
Association, Inc.,
Batterymarch Park, Quincy,
MA 02269.
INSTALLATION
LOCATING YOUR OUTDOOR GAS FIREPLACE
1) When selecting a location for your fi replace, ensure that the clearances are met.
2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant heat and could become damaged.
4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall comply with one of the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover.
Within a partial enclosure that includes an overhead cover and no more that two walls.
Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply:
• At least 25% of the total wall area is completely open, and
• At least 30% of the remaining wall area is open and unrestricted
30% or more in total of the remaining wall area is open and unrestricted.
Open side at least 25% of total wall area
IMPORTANT: Minimum ambient air temperature for the fireplace operation is 0°C (32°F)
3
4
PRODUCT ASSEMBLY
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specially approved with this appliance may result in property damage or personal injury.
colored glass or lava rock) on top of burner media as shown on a picture.
INSTALLATION
CAUTION: Do not remove the metal data plates attached to the
Fire
Feature. These plates contain important information.
1. Remove Burner Assembly,
Front Cover and Burner
Media from packaging (see
Parts List, page 14 ).
2. Connect the Burner Assembly to gas supply using supplied flex connector and shutoff valve.
3. Evenly fill the media compartment with burner media (broken tempered glass) fully covering the burner as shown on a picture.
If you are NOT planning to add optional topping media, then fill the proceed to the step 5.
media compartment in full and
NOTE
: If you are planning to add some topping media
(optional colored glass or lava rock), leave approximately ¾” not filled on top of burner media and proceed to the next step.
4. Place and evenly distribute topping media (optional
Make sure that pilot opening is not blocked with excess of media.
5. Carefully leak test all connections following the procedure on page 5.
6. Having free access to the valve and manifold compartment of the Burner
Assembly turn ON the appliance following the procedure on page 8 .
Make sure the flame is even along the burner and appliance is fully operational and safe for use. Turn OFF the appliance and let it cool before proceeding to the next step.
7. Cover manifold and valve compartment of the Burner
Assembly with Front Cover.
Install the Rear Tray on opposite side from the burner.
8. Fill the tray s with topping media to desired level.
NOTICE: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that control compartment, burner and circulating air passageways of the appliance be kept clean.
WARNING:
Never light th e appliance without having the clear glass media completely covering the burner!
CLEARANCES TO
COMBUSTIBLE MATERIALS
FROM THE BURNER :
- Top……… 60” (153 cm)
- Short Side of the Unit
to Wall ……. . 8 ” (2 1 cm)
- Long Side of the Unit
to Wall …… 16” (41 cm)
No Thermal Floor Protection Required
Fuel pressure specification:
Inlet Nat. Gas (NG) Min: 4.5” w.c.
Max: 10.5" w.c.
Manifold (NG) 3.5” w.c.
Inlet Propane Min: 11.0” w.c.
Max: 13.0" w.c.
Manifold 10.0” w.c.
Fire Feature Enclosure Dimensions
NOTE: Fire Feature with Enclosure can be installed on any non-combustible materials.
Cover
(see Illustrated Parts List, page 1 5 )
must be in place when appliance is not in use.
5
FIREPLACE INSTALLATION
CHECK GAS TYPE
Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit.
INSTALLING GAS PIPING TO FIREPLACE / FIRE FEATURE LOCATION
WARNING
A qualified installer or service person must connect appliance to gas supply. Follow all local codes.
CAUTION
For propane units, never connect fireplace directly to the propane supply. This Fire
Feature requires an external regulator (not supplied). Install the external regulator between the Fire Feature and propane supply.
INSTALLATION ITEMS NEEDED
Before installing fireplace /Fire Feature , make sure you have the items listed below.
• External regulator (supplied by installer) • Piping (check local codes)
• Equipment shutoff valve* • Test gauge connection*
• Sealant (resistant to propane)
• Sediment trap (recommended)
• Tee joint • Pipe wrench
• approved flexible gas line with gas connector (if allowed by local codes — not provided)
* A CSA design-certified equipment shutoff valve with 1 /
8
" NPT tap is an acceptable alternative to test gauge connection.
Purchase the CSA design-certified equipment shutoff valve from your dealer.
For propane connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, Fire Feature regulator damage could occur. Install external regulator with the vent pointing down as shown in
Figure 1 . Pointing the vent down protects it from freezing rain or sleet.
External
Regulator
100 lb. (min)
Propane
Supply Tank
CAUTION
Use only new black iron or steel pipe. Internally tinned copper or copper tubing can be used per
National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes. Gas piping system must be sized to provide minimum inlet pressure (listed on data plate) at the maximum flow rate (BTU/hr). Undue pressure loss will occur if the pipe is too small.
Vent Pointing
Down
When using copper or flex connectors use only fittings approved for gas connections. The gas control inlet is 3 /
8
" NPT.
6
Figure 1 - External Regulator with Vent Pointing Down
(Propane Only)
CONNECTING TO GAS
SUPPLY
WARNING: A qualified service person must connect appliance to gas supply. Follow all local codes.
Installation Items Needed
Before installing the Outdoor
Fire place , make sure you have all
items listed bellow:
piping (check local codes)
sealant
manual shutoff valve
adjustable (crescent) wrench or pliers
sediment trap
tee joints
pipe wrench
CAUTION: Use only new, black iron or steel pipe.
Internally tinned copper tubing may be used in certain areas. Use pipe of
1/2" diameter or greater to allow proper gas volume to
Fire Feature .
If pipe is too small, undue lossof pressure will occur.
traps moisture and contaminants.
This keeps them from going into
Outdoor Fire place controls.
If sediment trap is not installed or is installed wrong, unit may not run properly.
CHECKING GAS
CONNECTION
WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water on all joints.
Bubbles forming show a leak. Correct all leaks at once.
Approved Flexible
Gas Connector
Test Pressures in Excess Of
1/2 psi (3.5 kPa)
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
Test Pressures Equal To or
Less Than 1/2 psi (3.5 kPa)
The appliance must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
IMPORTANT
This appliance is not designed for use with a non-disposable, self-contained propane supply
system! Do not use a gas hose to connect the appliance to any gas supply. Use approved
Flexible Gas Connectors.
Installation must include a manual shutoff valve, union, and plugged
1/8” NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from the appliance.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.
Install sediment trap in supply line as shown below. Locate sediment trap where it is within reach for cleaning and trapped matter is not likely to freeze. A sediment trap
A.G.A. Design-Certified
Manual Shutoff Valve
With 1/8” NPT Tap
3” Minimum
From Gas Meter
(5” W.C. to 10.5” W.C.
pressure)
Cap Pipe Nipple Tee Joint
Sediment Trap
7
FIRE FEATURE SPECIFICATIONS
BURNER DIMENSIONS
1.5"
6" 7"
4.25"
4"
BURNER TUBE
TOP COVER
2.5"
PILOT
3"
MEDIA BURNER TRAY
10" 1 6 "
OVERAL WIDTH (W)
*
4"
TOP COVER DIMENSIONS
1"
WELD-ON HANDLE
17.5"
TOP COVER WIDTH (W+0.
6 5")
8
MODEL
FF 24 - N (P )
OVERALL
WIDTH ( W )
BURNER TUBE
LENGTH
24" 20"
INPUT RATE (B tu / hr )
N.G. P ropane
41,000 33,500
FF 36 - N (P)
36" 32" 61,000 54,000
FF 48 - N (P) 48" 44" 82,000 72,000
FF
FF
60 - N
72 - N
(P)
(P)
60" 56" 102,000 90,000
72" 68" 116,000 110,000
FF 84 - N (P) 84" 80"
FF 96 - N (P) 96" 92"
129,000 128,000
142,000 146,500
# ORIF.
N.G. (P rop)
2 (1)
ORIF. SIZE
N.G. P rop
44 49
3 (1) 44 4 3
4 (1) 4 3 38
5 (2) 4 3 46
6 (2) 43 41
7 (2) 43 38
8 (2) 43 35
32 L100001
LIGHTING
INSTRUCTION
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A.
This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand .
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Main gas valve in this appliance is not serviceable and does not have any control knobs or switches to operate.
Do not remove heat shields covering the valve and electronic devices; do not try to repair or modify the valve as it may result in a fire or explosion. Call a qualified service technician if you have any safety concerns.
D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
LIGHTING FOR THE FIRST TIME
INITIAL LIGHTING
Purge air from the supply line as follows:
DANGER
Never use an open flame to check for gas leak.
• Open main shutoff valve.
• Unscrew main pressure test point.
• Leave inlet test screw open until gas comes in.
• When gas is flowing, tighten inlet screw immediately.
LEAK TESTING
1.
Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and water mixture.
2.
Next check for gas leaks at the burner with soap and water mixture.
3.
Check the pilot for gas leaks with soap and water mixture.
9
Continued
LIGHTING FOR THE FIRST TIME
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
WARNING
• Soap and water solution
WARNING
• An approved leak testing spray
• Electronic sniffer
If using a soap and water solution to test for leaks, DO NOT spray solution onto electronic parts .
DANGER
Never use an open flame to check for gas leak.
NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.
Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections, pilot
• All joints on valve and control body
•
•
Field made joints / gas shutoff valve
Factory made joints, each joint and connection
OPERATING INSTRUCTIONS
1.
STOP! Read the safety information on previous page.
2. Turn off all electric power to the appliance.
3. Do not attempt to light the pilot by hand.
4. Remove Front Tray from the appliance (see Illustrated Parts List, page 14).
5. Turn the gas control manual valve to the full OFF position.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the safety information (see page 7).
If you don't smell gas, go to the next step.
7. Turn the gas control manual valve to the ON position.
WA
8. Plug supplied 7V DC adapter into 110V power outlet.
9. Connect the wire to the DC input plug at the unit.
10. Lift and remove Heat Shield covering electronic components inside of the unit (see Illustrated Parts List, page 13).
11. Locate Remote Receiver inside of the unit (see Illustrated Parts List, page 13).
Make sure that the slider switch of the Receiver is in "REMOTE" (middle) position.
12. Replace Heat Shield and then replace Front Tray.
13. Read and follow instructions in how to set up and to use remote control described in supplied
"INSTALLATION AND OPERATING INSTRUCTIONS FOR SKYTECH MODEL: 1001 T/LCD-A"".
14. If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.
10
L100001 35
34 L100001
Continued
T
TO TURN OFF GAS TO APPLIANCE
1.
Turn off all electric power to the appliance if service is to be performed.
Unplug 7V DC adapter from the power outlet.
2.
If necessary, remove Front Tray from the appliance to access manual shutoff valve on gas line.
3.
Turn the gas control manual valve to the full OFF position.
4.
If necessary, replace Front Tray.
ELECTRICAL WIRING
This fireplace requires 110V AC electrical supply for normal operation in order to power up 7V DC adapter which is required to operate Remote Control. However, during power outage situation, its electronic system (DFC board) can be temporar il y powered with 6 V DC bat t ery pack (4 AA batteries).
WARNING
Electrical connections should only be performed by a qualified, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA
70 (latest edition) and Canadian Electrical Code, CSA C22.1.
CAUTION
Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation.
WARNING
Do not operate the appliance without the burner being completely filled with glass media.
Lighting the burner without the glass media will cause unsafe temperatures within the appliance.
11
CLEANING AND MAINTENANCE
WARNING
Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season.
BURNER, PILOT AND CONTROL COMPARTMENT
Keep the control compartment clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
PILOT FLAME
The fames from the pilot should be visually checked as soon as the unit is installed and periodically during normal operation. The pilot flame must always be present when the fireplace is in operation or connected to the gas line with main shutoff valve open and the IPS activated (powered) . The pilot flame has two distinct flames, one engulfing the flame sensor and the other reaching to the main burner.
Pilot Flame
BURNER normal operation.
Keep the appliance and its burner clean by vacuuming or brushing at least twice a year. Make sure the burner porting and burner air openings are free of obstructions at all times.
Inspect area around the burner. Remove any lint or foreign material with a brush or vacuum.
The burner must be replaced prior to the appliance being put into operation if it is evident that the burner is damaged. Please refer to "Illustrated Parts List" for the replacement part number specified by the manufacturer.
1 2 1
OBSERVED PROBLEM
TROUBLESHOOTING
WARNING: Turn off the unit and let cool before servicing. Only a qualified service person should service and repair this appliance .
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM POSSIBLE CAUSE
Unit is smoking / sooting excessively
( Note : It is natural and unavoidable for appliance sets to produce moderate levels of carbon (soot) where flames contact the media . This is especially true with propane gas.)
REMEDY
1. Poor fuel quality
2. Fireplace venting system not drafting properly
3. Excessive flame impingement or blockage
4. Improper fuel/air mixture
5.
Not enough media over burner tube.
1. Contact local natural or propane gas company
2. Adjust damper wide open and/or have fireplace and venting professionally cleaned and checked
3. Separate the stones to allow more flame passage
4. Remove any foreign items from the flame pattern and/or check for proper orifice sizing
5.
Make sure burner tube is completely covered
with glass media.
Burner is excessively noisy
( Note: The movement and combustion of gas will create low, unavoidable levels of noise.)
1. Passage of air/gas across irregular surfaces
2. Excessive gas pressure on natural gas units
1. Relieve any tight bends or kinks in gas supply line
2. Check/reset gas regulator pressure
Burner flame is too low or too high
Remote does not function
1. Incorrect gas supply or pressure
2. Blocked burner orifice or burner manifold ports
3. Improper burner orifice size
1. Battery is not installed. Battery power is low
1. Check for proper gas supply pressure
2. Free burner orifice and manifold ports of any burrs, paint, or other blockage i.e. spider webs, etc.
3. Verify proper burner orifice sizing (see page 8 )
1. Replace batteries in receiver and remote control . Re-program the receiver.
1 3
14 position
Gas odor during combustion
Continued
OBSERVED PROBLEM
When remote control / switch is pressed, there is spark at pilot but no ignition
POSSIBLE CAUSE
1. Gas supply turned off or manual shutoff valve closed
2. Air in gas lines when installed
3. Pilot adjustment screw closed
4. Pilot is clogged
5. Ignitor electrode broken
REMEDY
1. Turn on gas supply or open manual shutoff valve
2. Purge air from the supply line
(see page )
3. Adjust pilot flame for approximately
1" blue flame
4. Clean pilot (see Cleaning and Maintenance, page 1 ) or replace pilot assembly.
5.
Replace pilot assembly.
Burner does not light after pilot is lit 1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Flame sensor leads disconnected .
5. DFC Module failure.
1. Clean burner orifice
2. Contact local natural or propane gas company to check pressures and gas pipe sizing.
3.
Replace burner orifice
(s).
4. Reconnect leads .
5. Replace DFC module.
Delayed ignition burner 1. Pilot flame needs adjusting
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating unit where impurities in air exist may create odors.
Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
Unit produces unwanted odors 1. Unit burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See statement above).
2. Gas leak. See Warning statement above.
1. Adjust pilot flame for approximately
1" blue flame
1. Open flue to maximum. Stop using odor causing products while unit is running
2. Locate and correct all leaks (see Checking Gas Connections, page 7)
Gas odor even when Remote Control is in OFF position
1. Gas leak. See Warning statement above.
2. Main gas valve defective
1.
Locate and correct all leaks (see p.7)
2. Replace gas valve
.
1. Gas leak. See Warning statement at top of page
1. Locate and correct all leaks (see Checking Gas Connections , page 5 )
13
O W N E R ’ S O P E R A T I O N A N D I N S T A L L A T I O N M A N U A L
1 5
ILLUSTRATED PARTS LIST
FOR PART DESCRIPTION SEE NEXT PAGE
16
9
18
13
7
4
8
5
14
15
17
2
6
1
3
12
10
16
11 1
9
Key
# Part Description
PARTS LIST
This list contains replaceable parts used in your Fire Feature appliance
All replacement parts should be ordered from your
www.
woodbridgedealer .com retai ler or from
Woodbridge Fireplace Inc.
at 1-905-564-3001 or on-line at
Part Number according to the Fire Feature Natu ra l Gas model (and Propane)
FF2 4 FF 36 FF 48 FF 60 FF 72 FF84 FF 96
Q-ty
1 Burner Assembly
NG (P
NG (P ropane ropane )
)
2 Main Gas Valve
NG ( Propane )
3 Pilot Assembly
W110202
(W120202)
W120203
(W120203)
R100026
(R100027)
R100026
(R100027)
W110204
(W120204)
W120205
(W120205)
R100026
(R100027)
R100026
(R100027)
(R100029) (R100029) (R100029) (R100029)
W110206 W110207 W110208
(W120206) (W120207) (W120208)
1
R100026 R100026 R100026
(R100027) (R100027) (R100027)
1
R100028 R100028
(R100029) (R100029)
R100028
(R100029)
1
4 Burner Flex Connector C1000 10 C1000 10 D3 000 98 D300098 D300098 D300098 D300098
5 DFC Wire Assembly
6
Valve Bracket
(NOT SHOWN)
H100141
D400260
H100141
D400260
H100141
D400260
H100141
D400260
7 Valve Heat Shield D400261 D400261 D400261 D400261
8 Manifold complete with Tubing Assembly
MISC. MISC.
W130204 W130205 W130206 W130207 W130208
(MISC.) (MISC.) (MISC.) (MISC.) (MISC.) (MISC.) (MISC.)
NG (P ropane )
1
1
1
1
1
Continued on Next Page
Key
Part Description
#
9 Orifice for NG models
(Air m ixer for propane
model s )
PARTS LIST (CONTINUED)
This list contains replaceable parts used in your Fire Feature appliance
Part Number according to the Fire Feature Natural Gas model (and Propane)
FF 24
R100044
(R200061)
FF3 6
R100044
(R200062)
FF 48
R100043
FF 60 FF 72 FF84
R100043 R100043 R100043
FF 96
R100043
(R200063) (R200064) (R 2 0006 6 ) (R 2 0006 3 ) (R20006 7 )
Q-ty
10 Front Tray
11
12
Rear Tray
Pilot Shield
13 Control Heat Shield
14 DFC Board
15 Remote Receiver
1 6 Remote Control
17 6 Volt Battery Pack
D400234 D400254 D400253 D400209 D400217 D400224 D400210 1
W100286 W100287 W100288 W100289 W100290 W100291 W100292 1
D400267
(D400290) (D400290)
D400267
(D400290) (D400290)
D400267 D400267
(D400290) (D400290)
D400267
(D400290)
1
D4002 65 D4002 65 D400265 D400265 D400265 1
H100142 H100142 H100142 H100142 H100142 1
RCB-R RCB-R RCB-R RCB-R RCB-R RCB-R RCB-R 1
RCB RCB
H1001 39 H1 001 39
RCB
H1001 39 H1
RCB RCB RCB
001 39 H1001 39 H100139
RCB 1
H1001 39 1
18 7V 10mA DC adapter H1 00140
19 Enclosure Cover
H1 00140 H100140 H100140
W100279 W100280 W100281 W100282 W100283 W100284
H100140
W100285
1
1
- Burner Glass Media G100030 G100030 G100030 G100030 G100030 G100030 G100030 Pkg
/standard/
- Topping Media MISC. MISC. MISC.
MISC.
MISC. MISC. MISC.
Pkg
Pilot Assembly
6 Volt Battery Backup ( uses 4 pcs AA Batteries)
17
INSTALLATION RECORD
The installer should complete the form below that describes the details of the installation. Having this written record of installation information available will greatly expedite trouble-shooting should any problem arise with your fireplace. The installer should keep a duplicate of this form for their records. Accurate completion of this form is required for warranty coverage and for any technical support by Woodbridge
Fireplace Inc .
Date Purchased:
Purchaser/Dealer:
Installer:
Fireplace S/N on product ID tag:
Date Installed:
FUEL: ◯ Natural Gas ◯
Inlet Pressure Measured After Installation:
Propane
Manifold Pressure Measured After Installation:
High Fire: In. W.C.
Low Fire:
In. W.C.
In. W.C.
CONFIGURATION:
ALTITUDE:
Feet Above Sea Level
Was Fireplace Derated?
◯
Yes
◯
No
If Yes To What Orifice Size?
Unusual Structure Near Appliance ?
◯ Inside Corner ◯ Trees/Shrubs ◯ Other
Termination: (Please Describe)
Prevalent Wind Conditions?
Other Installation Notes:
SMF32011
WARRANTY INFORMATION
KEEP THIS FOR WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
LIMITED LIFETIME WARRANTY
The following components are warranted for life to the original owner, subject to proof of purchase:
Burner Assembly .
BASIC WARRANTY
Woodbridge Fireplace Inc. warrants the components and materials in your appliance to be free from manufacturing and material defects for a period of two years from date of installation. After installation, if any of the components manufactured by Woodbridge Fireplace in the appliance are found to be defective in materials or workmanship, Woodbridge Fireplace will, at its option, replace or repair the defective components at no charge to the original owner. Woodbridge Fireplace will also pay for reasonable labor cost incurred in replacing or repairing such com - ponents for a period of two years from date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase.
This Limited Lifetime Warranty will be void if the appliance is not installed by a qualified installer in accordance with installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to (1) firebox/burner assembly damaged by accident, neglet, misuse, abuse, alterations, negligence of others, including the installation thereof by unqualified installers, (2) the costs of removal, reinstallation or transportation of defective parts on the appliance, or (3) indentical or consequential damage. All service work must be performed by an authorized service representative.
This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fitness for purpose and of all other obligations or liabilities. Woodbridge Fireplace does not assume for it any other obligations or liabilities in connection with sale or use of the appliance. I n states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you.
You may also have additiona l right not covered in the Limited Lifetime Warranty. Woodbridge Fireplace reserves the right to investigate any and all the claims against this Warranty and decide upon method of settlement. For information about this warranty contact :
Woodbridge Fireplace Inc.
1 305 Meyerside Dr., Mississauga
Ontario, Canada L 5 T 1C9
Tel.: 1905564 3001 www.woodbridge
dealer .com
Rev. No: 11/2020