Specification guide
Gas fireplaces
Important:
This guide has been written to help you select and order the right Rinnai gas
fireplace, associated components, and accessories. This information is not
intended to be an installation guide.
Rinnai is constantly improving its products, and as such, information and
specifications are subject to change or variation without notice. For the most upto-date information go to www.rinnai.co.nz.
We’d love to hear from you
If you have any feedback about this guide we’d love to hear
from you. Either email us (place ‘Rinnai Specification Guide
feedback in the subject heading), or call Customer Services.
For more information about buying, using, and servicing of Rinnai appliances
call: 0800 RINNAI (0800 746 624).
Rinnai New Zealand Limited
105 Pavilion Drive, Mangere, Auckland
PO Box 53177, Auckland Airport, Auckland 2150
Phone:
Fax:
Email:
Website:
(09) 257 3800
(09) 257 3899
info@rinnai.co.nz
www.rinnai.co.nz
www.youtube.com/rinnainz
www.facebook.com/rinnainz
www.rinnaitraining.co.nz
contents:
Gas fire range .........................................................4
Flueing options.......................................................5
Choosing the right gas fire .....................................6
Mantels, surrounds, and hearths ............................7
TV installation above a fireplace.............................8
Product specification pages
Evolve 950 specification .........................................9
Evolve 950 positioning ...........................................10
Evolve 950 burn media, frames and accessories ....11
Evolve 950 flueing options .....................................13
Evolve 950 flue components ..................................14
Evolve 950 ordering guide .....................................16
Arriva 752 specification...........................................17
Arriva 750 specification ..........................................18
Arriva 750/752 frames and burn media options ......19
Arriva 750/752 positioning......................................20
Arriva 750/752 flueing options................................21
Arriva 750/752 flue components.............................22
Arriva 752 ordering guide .......................................24
Arriva 750 ordering guide .......................................25
Symmetry RDV3611 specification ............................26
Symmetry RDV3611 positioning ..............................27
Symmetry RDV3611 frames and accessories ...........28
Symmetry RDV3611 flueing options ........................29
Symmetry RDV3611 flue kits and components........30
Symmetry RDV3611 ordering guide ........................32
Neo Inbuilt/Premium Classic specification ............34
Neo Inbuilt/Premium Classic positioning...............35
Neo Inbuilt/Premium Classic frames and ZCB ........36
Neo Inbuilt/Premium Classic flueing options.........37
Neo Inbuilt/Premium Classic flue components .....38
Neo Inbuilt/Premium Classic ordering guide .........39
Neo Freestanding specification .............................40
Neo Freestanding positioning................................41
Neo Freestanding frames and outer panel kits ......41
Neo Freestanding flueing options..........................42
Neo Freestanding flue components ......................43
Neo Freestanding ordering guide ..........................45
Compact 2 specification .........................................46
Compact 2 positioning ...........................................47
Compact 2 frames and zero clearance box ............48
Compact 2 flueing options .....................................49
Compact 2 flue components ..................................50
Compact 2 ordering guide .....................................51
Impression outdoor fire specification ....................52
Impression outdoor fire positioning ......................53
Impression outdoor fire accessories ......................54
Impression outdoor fire ordering guide ................55
Appendices
Appendix 1: Rinnai heating running costs ..............57
Gas fire range
Rinnai gas fires are designed and made in New Zealand. Blending functionality and style,
a Rinnai gas fire will be a focal point in any room. Hallmarks of our product range are
precise temperature control, beautiful design and top rating energy efficient heating.
Rinnai gas fire range summary table
Compact 2
Neo
Symmetry
Arriva
Evolve 950
Model
Suitable for
Glass
front
Flue type
Integrated
ZCB*
Input
MJ/h
Output
kW
Thermal
eff. on
high %
Heating
area m2
Remote
control
Evolve 950
Inbuilt
mock chimney
Yes
Power flue
Yes
10-34
2.4-8.1
86
82-125
Yes
Symmetry
RDV3611
Inbuilt mock
chimney
Yes
Direct vent
Yes
19-33
3.8-7.5
80
62-101
Yes
Arriva 750/752
Inbuilt mock
Yes
chimney and
existing masonry
Power flue
Yes
8-31.5
1.8-7.0
85
70-108
Yes
Neo inbuilt
Inbuilt mock
Yes
chimney and
existing masonry
Natural draft
No
14-30
3.0-6.9
80
69-107
ETR
option
only
Yes
Natural draft
No
14-30
3.0-6.9
80
69-107
ETR
option
only
Compact 2
Inbuilt mock
Yes
chimney and
existing masonry
Natural draft
No
9-25
1.6-5.0
73
50-77
No
Impression
Outdoor only
N/A
N/A
25-45
12.0
N/A***
N/A***
No
Neo
Freestanding
freestanding
plinth & console
No**
* ZCB = zero clearance box, a box that isolates the appliance from combustible materials
** Glass bi-fold door assembly can be purchased as an accessory
*** Reduced efficiency appliance—primarily designed for aesthetics
NB: Input, output, and efficiency will vary depending on gas type and flue configuration.
4 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Flueing options
The type of flue (natural draft, power flue, or direct vent) will dictate where a Rinnai gas
fire can be installed. When selecting a fire, check the flue type on the previous page. The
different flue types are explained below.
Natural draft
Often referred to as a standard flue system.
This type of flue draws the air for combustion
(to run the fire) from the room and then expels
air to the outside via a vertical flue. As the air
for combustion is being drawn from the room
there is a requirement for adequate ventilation
(requirement to replenish the air).
Natural draft
Adequate ventilation must be calculated and
provided by the gasfitter, as per AS/NZS 5601.1
The flue must terminate vertically through the
roof (refer p. 37).
Power flue
A Rinnai power flue system has a sealed
combustion chamber, with a fan, that draws air for
combustion from the outside (through the outer
flue) and expels gases to the outside (through
the inner flue). This type of system heats a room
without taking oxygen or heated air from the
room.
Power flue
Rinnai appliances flued by a power flue are
approved by the sensitive choice programme of
the Asthma foundation as they maintain air quality
for a healthy breathing environment.
Power flues are smaller in size, can have a number
of bends, can be flued down-and-out, sideways,
and can terminate horizontally or vertically. This
means power flued appliances can be installed
in almost any living or working space, including
bedrooms (refer p. 13).
Direct vent
A direct vent flue system, like the power flue, also
has a sealed combustion chamber, but differs by
using natural draft to draw air (from the outside)
and expel combusted gases (to the outside).
Like the power flue, the air quality of the room
being heated is maintained, which is why the
Symmetry is also approved by the sensitive choice
programme of the Asthma foundation.
Direct vent
Direct vent flues, as they use natural draft to move
air and gases through the flue system have a
larger flue size (compared to the power flue). The
flue can terminate horizontally or vertically (refer
p. 29)
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 5
Choosing the right gas fire
Consideration such as geographical location, room size, room insulation, and
functionality versus aesthetics all play a part in choosing the right gas fire.
Geographical location
Where you live in New Zealand
can determine the type of
heating solution you choose.
The diagram shows nationwide
winter climate zones. It is
important to correctly identify
your climate zone as it directly
affects the performance of your
heating solution.
*RADIUS
Warm
zone
Medium zone
Room size
Consider the whole area you
need to heat. This should
include adjacent rooms through
permanently open doorways
and hallways.
A useful guide when calculating
the size of heater you need for a
room is to measure the volume
(length x width x height, in
metres) and divide by 20 to get
the kW rating of the appliance
needed.
Functionality vs. aesthetics
Additional considerations are
based on functionality, the look
of the fire, and where it is likely
to be installed.
For example; are electronic
timers and a fully programmable
remote control important, or is
simplicity a key factor? Is the fire
required to replace an existing
fireplace in a masonry chimney,
or is a new mock chimney being
built?
Cool zone
HEATING AREA
Gas Fireplace
Warm zone Medium zone Cool Zone
Evolve 950
125 m2
111 m2
82 m2
Arriva
108 m2
95 m2
70 m2
Neo
107 m2
93 m2
69 m2
Symmetry RDV3611
101 m2
77 m2
62 m2
Compact 2
77 m2
68 m2
50 m2
As an estimate you can make the following deductions from the heating
areas shown for specific heat loss factors .
If you have:
Deduct above heating
area by:
No ceiling insulation
10%
Wooden floor (not concrete slab)
5%
No carpets
5%
No curtains on single-glazed windows
5%
No curtains on single-glazed windows, area
exceeding 15 m2
10%
Ceiling height 2.5-2.8 m
3%
Ceiling height 2.8-3.0 m
5%
Ceiling height 3.0 m +
7%
For example: The Evolve 950 will heat 125 m2 (warm zone). If there is no
ceiling insulation this area reduces by 10% to become 112.5 m2.
6 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Mantels, surrounds, and hearths
Mantels, surrounds, and hearths can be added to complement design, providing they
conform to the clearance requirements and guidelines stated in this guide.
Mantels and surrounds
Clearance requirements of
mantels and surrounds made
of combustible material, such
as wood, will vary between
models due to the way in which
a fire is designed and how
heat is dispersed into a room.
The position of a mantel and
surround will vary if the fire has
a curved or flat front, has a fan,
or even how thick the frame is.
Arriva models have reduced
clearances compared to all
other Rinnai gas fires due
to their unique bottom air
discharge.
Example of a mantel and surround diagram
B
D
A
C
For individual mantel and
surround clearances for each
model, refer to the specific
positioning pages of each
model.
Hearths
A hearth is not necessary for
Rinnai gas fires, but can be used
for decorative purposes, or
protection of sensitive flooring
materials. Some flooring can
discolour from the radiant heat
generated by the appliance.
General hearth guidelines
General guidelines if installing
a hearth, or installing a gas fire
when there is already a hearth,
such as in an existing masonry
fireplace.
t It must not obscure the
front of the fire.
t The bottom of the appliance
must be level with the top
of the hearth so there is a
continuous level.
Ensure continuous level
t It should be at least the
width and depth of the fire.
If installing a hearth remember
to adjust the height of the cavity
to allow for the hearth.
Adjust dimensions of the cavity
to allow for hearth
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 7
TV installation above a fireplace
If installing a flat screen TV above a fire, the main issue is heat. Heat from the fire, and
heat from the flueing components that could be installed behind the TV (especially if
recessed).
The Rinnai gas fires below
all have a powerful fan that
distributes warm air from the
appliance out into the room. As
warm air is dispersed outwards,
as opposed to directly upwards,
installation of a TV may be an
option.
TV directly above
At least the
depth of the TV
Models with a powerful fan:
t Arriva 750/752
t Evolve 950
t Symmetry RDV3611
t Neo
Refer clearance
information for
each model
The general rule for television
installations is that the bottom
of the television recess should
be at least 400-450 mm above
the fire.
For a TV mounted directly
above a fire, the mantel must
be at least the depth of the TV
to deflect heat away from the
appliance.
Always check with the TV
manufacturer
Some television warranty
conditions state that a TV
is not to be installed above
a fireplace—always check
with the TV manufacturer
beforehand.
Rinnai does not accept any
responsibility for damage to a
TV resulting from the use of this
information.
Compact 2 not suitable
Installing a TV directly
above the Compact 2 is not
recommended due to the heat
being emitted directly above
the fire (especially when the fan
is not operational), and also due
to the heat being generated
from the flue components.
8 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
TV recessed
400 mm
minimum
Rinnai gas fireplaces
Product
specification
pages
Evolve 950 specification
Inbuilt exhaust balance flued
convection gas fire with electronic
temperature control, timer, and
remote. Different frame and burn
media options available.
Specification summary
Input
= 10-34 MJ/h
Output
= 2.4-8.1 3* kW
Efficiency
= 86% (on high)
Heating area
= 82-125 m2**
Gas type
= NG or ULPG
Suitability
Ideal for living rooms and open plan
areas. Versatile power flue system
makes for easy installation in almost
any living space, including bedrooms.
The Evolve is best suited for a new
build installation into a false (mock
chimney).
Burn media
Choice of river stones or oak log set.
Noise level: 37-45 dB(A)
Convection fan
3-speed fan. Heat is distributed from
the top of the appliance.
Power flue
Inner 50 mm, outer 70-80 mm.
Appliance must be installed with a
Rinnai flue system.
Data plate
Located inside the appliance, upper
right hand side.
Power consumption and electrical
supply
High
= 160 W
Standby = <8 W
Gas connection
½ “ BSP, the gas supply terminates
inside the heater—lower left hand side
of the appliance.
Ignition
Continuous spark electronic ignition.
Installation considerations: Room size
The Evolve is not suitable for smaller
rooms. This is due to the efficiency
of the appliance. Smaller rooms will
heat up quickly and once the set
temperature has been reached the
flame picture will reduce significantly
(and in some cases reduce to pilot
only). This is not ideal if customers
want a full flame picture to be visible
for the majority of time that the heater
is on.
This heater has a 1.5 m power cord
with a 3-pin plug supplied. The power
cord passes through a slot in the back
right hand corner of the appliance.
Safety devices
Flame failure sensing system, pressure
relief, overheat safety switch, air
temperature sensor, thermal fuse,
overcurrent fuse, and spark detector.
Temperature control
Thermostat control. Temperature
control range 16-26 °C (low to high).
Weight - 75 kg
®
Fan
Preheat
function
Timer
Remote
control
* Will vary according to gas type and flue configuration
Electronic Air filter
ignition
up to 5.7 STARS
Child lock
SUPP OR T IN G
A S T H M A CA RE
** Will vary depending on geographical location in NZ
430
420
660
500 ±25
1070
560
SENSITIVE
CHOICE
65
Thermostat
controlled
960
25
568
25
All dimensions are in mm.
10 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Evolve 950 positioning
Framing dimensions
The main points governing location are flueing
and warm air distribution. The Rinnai Evolve has
an integrated zero clearance box that isolates
the appliance from combustible materials. This
means it can be installed directly into a decorative
fireplace constructed from materials such as wood
or plaster.
W-width
H-height
D-depth
W
= 965-980 mm
= 570-580 mm
= 570 mm minimum
H
D
Clearances from combustibles - measured
from the edge of the glass
WHILE THE HEATER IS OPERATING
The appliance must not be installed where
curtains or other combustible materials could
come into contact with the heater. In some cases
curtains may need restraining. The clearances are
minimum clearances unless otherwise stated.
= 400 mm (1000 mm to ceiling)
= 400 mm (includes side walls)
= 1000 mm
1000
Above
Sides
In front
A Mantel height from top of glass
400 mm min.
B Mantel depth at A - 400 mm
(vertical clearance)
250 mm max.
400
MANTELS AND SURROUNDS
Mantels and surrounds, made of combustible
materials, are allowed providing they are outside
the minimum clearances shown.
400
400
For every 50 mm of added mantel depth, there must be
an additional 100 mm of vertical clearance. For example;
a mantel depth (B) of 350 mm will require 600 mm (A) of
vertical clearance.
C Surround from side of glass
250 mm min.
D Surround projection at C - 250 mm
(side clearance)
250 mm max.
B
D
A
C
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 11
Evolve 950 burn media, frames and accessories
Oak log set
River stones
Black on black frame
Code: R2781
Code: R2780
Code: R2770
Consists of eight realistic log pieces
(designed to look like split logs)
and two granule packs.
Consists of 30 stones (10 white and
20 grey), and two granule packs.
Black powder coated metal inner
and outer frame.
Stainless steel on black frame
Mesh guard
Code: R2771
Code: R2779
Stainless steel inner frame, and
black powder coated metal outer
frame.
To protect little hands from
touching the hot glass. The mesh
itself is black and sits flush with the
inner frame (inner frame holds it in
place).
660
441
305
Additional notes
We often get enquiries about the inner and outer frame measurements. Below is a graphic that has the
internal and external frame dimensions. The frame itself sits approximately 25 mm out from the wall,
refer dimension diagram on p. 10.
700
820
1070
12 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Evolve 950 flueing options (most common)
Direct
Flue component:
onent:
- Direct fluee (ASPDFK)
Vertical in-wall
Flue components:
03)
- Adaption flue (EVOKIT03)
- Flue pipe (ESPIPE900)
WL)
- Roof cowl (ESROOFCOWL)
Sideways through-wall
Down-and-out
Flue components:
onents:
- Adaption
n flue (EVOKIT03)
- Flue pipe (ESPIPE900)
- Wall terminal
minal (ESWTERM)
Flue components:
ts:
- Adaption flue (EVOKIT03)
PE900)
- Flue pipe (ESPIPE900)
- 90 ° bend (ESBEND)
END)
- Wall terminal (ESWTERM)
ESWTERM)
Vertical through-wall (45 °bends)
Vertical through-wall (90 ° bends)
Flue components:
- Adaption flue (EVOKIT03)
VOKIT03)
- Flue pipe (ESPIPE900)
E900)
ND)
- 45 ° bends (ESBEND)
- Roof cowl (ESROOFCOWL)
OOFCOWL)
Flue components:
ents:
- Adaption fluee (EVOKIT03)
- Flue pipe (ESPIPE900)
SPIPE900)
- 90 ° bends (ESBEND
ESBEND x 2)
- Roof cowl (ESROOFCOWL)
ESROOFCOWL)
Maximum flue length is 8.5 m. Maximum number of bends is three. One 90° bend equals 1 m. For every 90° bend
the overall length must be reduced by 1 m. For example, if an installation has three 90° bends, the maximum flue
length will be 5.5 m. EVOKIT03 is counted as one 90° bend.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 13
Evolve 950 flue components
115 mm
120
120
330 mm
Ø 80
65 mm
540 mm
43 mm
140 mm
50 mm
Ø 75 mm
Ø 75
Direct flue kit
Evolve adaption flue kit
45° flue bends (x2)
Code
Code
Code
= ASPDFK (aluminium)
Suitable for walls up to 385 mm (can
be cut to length).
Can also be used in combination
with ESPIPE900 for longer flueing.
Flue terminal section is reusable
when making flue longer.
= EVOKIT03
= ESBEND
Elbow section of this component
(circled) requires a 25 mm
clearance from combustibles, the
rest is zero clearance.
Two 45° bends used to facilitate
between horizontal, vertical, and
downwards flueing. Two spacers
are included.
Kit includes; flue transition
(rotates), condensate trap, wall
strap, drain tube (750 mm), silicone
grease, and flue slide stopper
(4822).
Can be used separately, or together
as one 90° bend.
Approx. 155 mm
External wall plate
Flue terminal
22mm
x6
7mm
x2
False wall
Ø 170 mm
Mounting/securing screws
Wall terminal kit
Wall plate (black or white)
Condensate trap
Code
Code
Code
= ESWTERM
Used to terminate the ESPIPE900
in horizontal flue installations
when used in conjunction with the
EVOKIT03.
Contains:
t External wall plate (black PVC)
t Flue terminal (aluminium)
14 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
= ESPLATE
Used if an extra wall cover
is required to tidy any installation
through the wall, ceiling, or floor.
N.B: Currently in stock are two
colours options. Please specify if a
particular colour is required.
= ESCONDK
Supplied with a 750 mm drain tube
(not pictured). ONLY ordered as a
separate item if doing a horizontal
through-wall vertical flueing
installation as shown above.
Female end
(do not cut)
975 mm
900 mm
35 mm
165 mm
Ø 50 mm
Male end
(can cut)
Ø 50 mm
Ø 75-80 mm
25 mm
Ø 75-80 mm
Coaxial flue pipe 900 mm
Vertical terminal
Steel flue guard
Code
Code
Code
= ESPIPE900
= ESROOFCOWL
= R1370
Extension pipe used to construct
horizontal, vertical, and downwards
flueing. Can be cut to size.
Roof cowl and connecting pipe for
termination of a vertical flue—can
be cut to size.
Protection against hot flue gases
when the termination is low to the
ground.
Inner is aluminium, and outer is
white PVC plastic.
Galvanised steel, powder coated
black.
Colour - warm white.
Comes with one wall bracket,
o-ring (4350), and spacer (4351).
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 15
Evolve 950 ordering guide
1. Select gas type (engine)
Evolve NG engine
RHFE950ETRN
Evolve LPG engine
RHFE950ETRL
Supplied with the engine is the remote control and batteries, remote control mounting bracket, screw pack,
cable tie, frame mounting screws, and two granule packs
2. Select frame option
Black on black
R2770
Stainless steel on black
R2771
Oak log set
R2781
River stones
R2780
Direct flue kit
ASPDFK
Adaption flue kit
EVOKIT03
Vertical terminal (roof cowl)
ESROOFCOWL
Flue pipe 900 mm
ESPIPE900
Wall terminal kit
ESWTERM
45° flue bends (two in a kit)
ESBEND
Wall plate
ESPLATE
Steel flue guard
R1370
Condensate trap
ESCONDK
3. Select burn media
4. Select flue components
Max. flue length is 8.5 m. Max. number of bends is three. One 90° bend equals 1 m. For every 90° bend the overall
length must be reduced by 1 m. For example, if an installation has three 90° bends, the maximum flue length will
be 5.5 m. EVOKIT03 is counted as one 90° bend.
The condensate trap is included with the EVOKIT03. It only needs to be ordered separately if you are doing a
horizontal through-wall flueing combination (not common).
5. Select optional accessories
Black mesh guard
16 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
R2779
Arriva 752 specification
Burn media
Choice of black pebbles or white
quartz.
Noise level: 33-41 dB(A)
Power flue
Inner 50 mm, outer 70-80 mm.
Appliance must be installed with a
Rinnai flue system.
Convection fan
3-speed fan (high, medium, and low)
radial blower fan. Heat is distributed
from the bottom of the appliance.
Inbuilt exhaust balanced flued
convection gas fire with electronic
temperature control, timer and
remote. Different frame and burn
media options available.
Power consumption and electrical
supply
High
= 90 W
Low
= 60 W
Standby = <8 W
Data plate
Inside appliance, upper right hand side
(beside the convection fan).
Gas connection
½ “ BSP male flare barrel union (lower
right hand side of appliance).
Specification summary
Input
= 8-31.5 MJ/h
Output
= 1.8-7.0* kW
Efficiency
= 79-89%
Heating area
= 70-108 m2**
Gas type
= NG or ULPG
This heater has a 1.5 m power cord
with a 3-pin plug supplied. The
standard electrical connection is to
the right hand side of the appliance.
Ignition
Continuous spark electronic ignition.
Suitability
Ideal for living rooms and open plan
areas. Versatile power flue system
makes for easy installation in almost
any living space, including bedrooms.
The Arriva is ideal for a new build
installation into a false (mock)
chimney, but can be fitted into an
existing masonry fireplace if it is big
enough.
Safety devices
Flame failure sensing system, pressure
relief, overheat safety switch, air
temperature sensor, thermal fuse,
overcurrent fuse, and spark detector.
Installation considerations: Room size
The Arriva is not suitable for smaller
rooms. This is due to the efficiency
of the appliance. Smaller rooms will
heat up quickly and once the set
temperature has been reached the
flame picture will reduce significantly.
This is not ideal if customers want a
full flame picture to be visible for the
majority of time that the heater is on.
Temperature control
Thermostat control. Temperature
control range 16-26 °C (low to high).
Weight - 70 kg
®
Thermostat
controlled
Fan
Preheat
function
Timer
Remote
control
* Will vary according to gas type and flue configuration
Electronic
ignition
Air filter
up to 5.6 STARS
Child lock
SENSITIVE
CHOICE
SUPP OR T IN G
A S T H M A CA RE
** Will vary depending on geographical location in NZ
710
1050
230
76
B
845
365
660
A
Two piece frame: A = 98, B = 20
Single frame:
A = 90, B = 12
365
Dimensions are in mm.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 17
Arriva 750 specification
Noise level: 33-41 dB(A)
Burn media
Log set comes as standard.
Convection fan
3-speed fan (high, medium, and low)
radial blower fan. Heat is distributed
from the bottom of the appliance.
Inbuilt exhaust balanced flued
convection gas fire with electronic
temperature control, timer and
remote. Different frame options
available.
Specification summary
Input
= 8-31.5 MJ/h
Output
= 1.8-7.0* kW
Efficiency
= 79-89%
Heating area
= 70-108 m2**
Gas type
= NG or ULPG
Suitability
Ideal for living rooms and open plan
areas. Versatile power flue system
makes for easy installation in almost
any living space, including bedrooms.
The Arriva is ideal for a new build
installation into a false (mock)
chimney, but can be fitted into an
existing masonry fireplace if it is big
enough.
Data plate
Inside appliance, upper right hand side
(beside the convection fan).
Gas connection
½ “ BSP male flare barrel union (lower
right hand side of appliance).
Ignition
Continuous spark electronic ignition.
Installation considerations: Room size
The Arriva is not suitable for smaller
rooms. This is due to the efficiency
of the appliance. Smaller rooms will
heat up quickly and once the set
temperature has been reached the
flame picture will reduce significantly
(and in some cases reduce to pilot
only). This is not ideal if customers
want a full flame picture to be visible
for the majority of time that the heater
is on.
Power flue
Inner 50 mm, outer 70-80 mm.
Appliance must be installed with a
Rinnai flue system.
Power consumption and electrical
supply
High
= 90 W
Low
= 60 W
Standby = 10 W
This heater has a 1.5 m power cord
with a 3-pin plug supplied. The
standard electrical connection is to
the right hand side of the appliance.
Safety devices
Flame failure sensing system, pressure
relief, overheat safety switch, air
temperature sensor, thermal fuse,
overcurrent fuse, and spark detector.
Temperature control
Thermostat control. Temperature
control range 16-26 °C (low to high).
Weight - 70 kg
®
Thermostat
controlled
Fan
Preheat
function
Timer
Remote
control
* Will vary according to gas type and flue configuration
Electronic
ignition
Air filter
Child lock
up to 5.2 STARS
SENSITIVE
CHOICE
SUPP OR T IN G
A S T H M A CA RE
** Will vary depending on geographical location in NZ
230
845
675
660
365
90
365
900
All dimensions are in mm.
18 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Arriva 750/752 frames and burn media options
Arriva 750 (Arriva 750 frames cannot be used on the Arriva 752)
750 satin black classic frame
750 stainless shine frame
Code: R2700
Code: R2701
A classic square style in matt black
steel.
A cool modernist look in stainless
steel.
Arriva 752 (Arriva 752 frames and burn media cannot be used on the Arriva 750)
752 flat black frame
752 flat stainless frame
752 stainless on black frame
Code: R2711
Code: R2712
Code: R2713
Single continuous flat black frame.
Single continuous flat stainless
steel frame.
Stainless steel inner on black outer
frame. Supplied in two pieces
(inner and outer).
752 black on black frame
752 stainless/stainless frame
752 black on stainless frame
Code: R2714
Code: R2715
Code: R2716
Black inner on black outer frame.
Supplied in two pieces (inner and
outer).
Stainless steel inner on stainless
steel outer. Supplied in two pieces
(inner and outer).
Black inner on stainless steel outer.
Supplied in two pieces (inner and
outer).
752 black pebbles
752 white quartz
Code: R2740
Code: R2741
Black glass pebbles for the Arriva
752.
Large and small white quartz stones
for the Arriva 752.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 19
Arriva 750/752 positioning
Framing dimensions
The main points governing location are flueing
and warm air distribution. The Arriva has an
integrated zero clearance box that isolates the
appliance from combustible materials. This
means it can be installed directly into a decorative
fireplace constructed from materials such as wood
or plaster.
W-width
H-height
D-depth
W
= 850-860 mm
= 660-665 mm
= 380 mm direct flue
= 475 mm extended flue
= 500 mm underfloor flue
H
D
Clearances from combustibles - measured
from the edge of the frame
WHILE THE HEATER IS OPERATING
The appliance must not be installed where
curtains or other combustible materials could
come into contact with the heater. In some cases
curtains may need restraining. The clearances are
minimum clearances unless otherwise stated.
Above
Sides
In front
250 mm
= 250 mm
= 100 mm
= 1000 mm
100 mm
MANTELS AND SURROUNDS
The Arriva models, due to their unique bottom
air discharge, have greatly reduced mantel and
surround clearances. The minimum clearance
above and to the side is 75 mm from the edge
of the frame. These clearances are important as
they:
t allow heat to escape in the event of a power
failure during operation
100 mm
1000 mm
t allow optimum performance of the heater
(room air return)
t allow access to the side mesh filters
A Mantel height from edge of frame
75 mm min.
B Mantel depth at A - 75 mm
(vertical clearance)
25 mm max.
For every 25 mm of added mantel depth, there must be
an additional 25 mm of vertical clearance. For example;
a mantel depth (B) of 50 mm will require 100 mm (A) of
vertical clearance.
C Surround from edge of frame
75 mm min.
D Surround projection at C - 75 mm (side
clearance)
25 mm max.
For every 25 mm of added surround projection there must
be an additional 25 mm of side clearance. For example; a
surround projection of 75 mm will require a side clearance
of 125 mm.
20 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
B
D
C
A
Arriva 750/752 flueing options (most common)
Direct
Flue component:
onent:
- Direct A flue (R2731), or
- Direct B flue (R2732), or
- Direct fluee (ASPDFK)
Vertical in-wall
Flue components:
- Adaption flue (ASPKIT03)
3)
- Flue pipe (ESPIPE900)
WL)
- Roof cowl (ESROOFCOWL)
Sideways through-wall
Down-and-out
Flue components:
onents:
- Adaption
n flue (ASPKIT03)
- Flue pipe (ESPIPE900)
- Wall terminal
minal (ESWTERM)
Flue components:
ts:
- Adaption flue (ASPKIT03)
- Flue pipe (ESPIPE900)
PE900)
- 90 ° bend (ESBEND)
END)
- Wall terminal (ESWTERM)
ESWTERM)
Vertical through-wall (45 °bends)
Vertical through-wall (90 ° bends)
Flue components:
SPKIT03)
- Adaption flue (ASPKIT03)
E900)
- Flue pipe (ESPIPE900)
- 45 ° bends (ESBEND)
ND)
OOFCOWL)
- Roof cowl (ESROOFCOWL)
Flue components:
ents:
- Adaption fluee (ASPKIT03)
SPIPE900)
- Flue pipe (ESPIPE900)
ESBEND x 2)
- 90 ° bends (ESBEND
- Roof cowl (ESROOFCOWL)
ESROOFCOWL)
Maximum flue length is 8.5 m. Maximum number of bends is three. One 90° bend equals 1 m. For every 90° bend
the overall length must be reduced by 1 m. For example, if an installation has three 90° bends, the maximum flue
length will be 5.5 m. ASPKIT03 is counted as one 90° bend.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 21
Arriva 750/752 flue components
115 mm
80 mm
240-400 mm wall thickness
540 mm
115 mm
50 mm
43 mm
115-240 mm wall thickness
140 mm
80 mm
Ø 75 mm
Outside wall terminal diameter - 140 mm
Outside wall terminal diameter - 140 mm
Direct A flue kit
Direct B flue kit
Direct flue kit
Code
Code
Code
= R2731 (stainless steel)
Mushroom flue kit for use in
walls 115-240 mm thick—typically
weatherboard construction (can
be cut to size). This is a complete
kit, no other components are
required.
t
Inbuilt 2° fall to drain
condensate
115 mm
Inbuilt 2° fall to drain
condensate
Arriva adaption flue kit
Code
330 mm
Long End
Condensate
tray
Condensate
drain hose
Barb (top)
Condensate
Tube
120
= ASPKIT03
Elbow section of this component
(circled) requires a 25 mm
clearance from combustibles, the
rest is zero clearance.
R1970
Short End
Can be used as an alternative to
R2731/R2732, and is suitable for
walls up to 385 mm (can be cut
to length). Can also be used in
combination with ESPIPE900
for longer flueing. Flue terminal
section is reusable when making
flue longer.
Ø 80
65 mm
Mushroom flue kit for use in walls
240-400 mm thick—typically block
construction (can be cut to size).
This is a complete kit, no other
components required.
= ASPDFK (aluminium)
Wire Tie
90° Bend
22 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
120
t
= R2732 (stainless steel)
Kit includes:
t Flue transition (rotates round)
t Condensate trap
t Wall strap
t Drain tube (750 mm)
t Silicone grease
t Flue slide stopper (4822)
t R1970 sub-kit
R1970 is a sub-kit called the
condensate drain kit. This is used
for installations that requires
draining of condensate back into
the heater.
Ø 75
45° flue bends (x 2)
Code
= ESBEND
Two 45 ° bends used to facilitate
between horizontal, vertical, and
downwards flueing. Two spacers
are included. Can be used separately, or together as one 90 °
bend.
Female end
(do not cut)
External wall plate
975 mm
900 mm
35 mm
165 mm
Ø 50 mm
Flue terminal
22mm
x6
7mm
x2
Mounting/securing screws
25 mm
Ø 75-80 mm
Male end
(can cut)
Ø 50 mm
Ø 75-80 mm
Coaxial flue pipe 900 mm
Vertical terminal
Wall terminal kit
Code
Code
Code
= ESPIPE900
Roof cowl and connecting pipe for
termination of a vertical flue—can
be cut to size.
Galvanised steel powder coated
black.
= ESWTERM
Used to terminate the ESPIPE900
in horizontal flue installations
when used in conjunction with the
EVOKIT03.
Contains:
t External wall plate (black PVC)
t Flue terminal (aluminium)
Approx. 155 mm
Extension pipe used to construct
horizontal, vertical, and downwards
flueing. Can be cut to size. Inner
is aluminium, and outer is white
PVC plastic. Comes with one wall
bracket, o-ring (4350), and spacer
(4351).
= ESROOFCOWL
False wall
Ø 170 mm
Steel flue guard
Wall plate (black or white)
Condensate trap
Code
Code
Code
= R1370
= ESPLATE
Protection against hot flue gases
when the termination is low to the
ground.
Used if an extra wall cover
is required to tidy any installation
through the wall, ceiling, or floor.
Colour - warm white.
N.B: Currently in stock are two
colours options. Please specify if a
particular colour is required.
= ESCONDK
Supplied with a 750 mm drain tube
(not pictured). ONLY ordered as a
separate item if doing a horizontal
through-wall vertical flueing
installation.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 23
Arriva 752 ordering guide
1. Select gas type (engine)
Arriva 752 NG engine
RHFE752ETRN
Arriva 752 LPG engine
RHFE752ETRL
Supplied with the engine is the remote control and batteries, remote control mounting bracket, screw pack,
cable tie, frame mounting screws, gas connection, and flue clamp bracket (for direct A/B flues).
2. Select frame option
Arriva 752 flat black frame
R2711*
Arriva 752 flat stainless frame
R2712*
Arriva 752 stainless on black frame
R2713**
Arriva 752 black on black frame
R2714**
Arriva 752 stainless/stainless frame
R2715**
Arriva 752 black on stainless frame
R2716**
* The flat frames (R2711/R2712) are supplied as a single frame.
** Supplied in two pieces—inner frame and outer frame
3. Select burn media
Arriva 752 black pebbles
R2740
Arriva 752 white quartz
R2741
4. Select flue components—refer next page
24 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Arriva 750 ordering guide
1. Select gas type (engine)
Arriva 750 NG engine
RHF750ETRN
Arriva 750 LPG engine
RHFE750ETRL
Supplied with the engine is the remote control and batteries, remote control mounting bracket, screw pack,
cable tie, frame mounting screws, gas connection, flue clamp bracket (for direct A/B flues), and log set.
2. Select frame option
Arriva 750 classic frame (matt black)
R2700
Arriva 750 shine frame (stainless steel)
R2701
Direct A flue kit (walls 115-240 mm)
R2731
Direct B flue kit (walls 240-400 mm)
R2732
Direct flue kit (walls up to 385 mm)
ASPDFK
Adaption flue kit
ASPKIT03
Vertical terminal (roof cowl)
ESROOFCOWL
Flue pipe 900 mm
ESPIPE900
Wall terminal kit
ESWTERM
45° flue bends (two in a kit)
ESBEND
Wall plate
ESPLATE
Steel flue guard
R1370
Condensate trap
ESCONDK
3. Select flue components
Max. flue length is 8.5 m. Max. number of bends is three. One 90° bend equals 1 m. For every 90° bend the overall
length must be reduced by 1 m. For example, if an installation has three 90° bends, the maximum flue length will
be 5.5 m. ASPKIT03 is counted as one 90° bend.
The condensate trap is included with the ASPKIT03. It only needs to be ordered separately if you are doing a
horizontal through-wall flueing combination (not common).
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 25
Symmetry RDV3611 specification
Burn media
Driftwood log set comes as standard.
Flue
Inner 100 mm, outer 170 mm.
Appliance must be installed with a
Rinnai flue system.
Convection fan
Fan forced 2-speed convection fan
(low and high). Heat is distributed
from the top of the appliance.
Power consumption and electrical
supply
High
= 50 W
Standby = < 1 W
Data plate
Centre front of base panel (behind the
service panels).
A direct vent (natural draft) inbuilt gas
fire with a glass front and convection
fan. Operated with a remote control
(7-day programmable timer). Different
frame options available.
This heater has a 1.5 m power cord
with a 3-pin plug supplied. The
standard electrical connection is to
the right hand side of the appliance.
Gas connection
½ “ BSP male flare. This connects
straight into the gas control on the
lower left hand side.
Specification summary
Input
= 19-33 MJ/h
Output
= 3.8-7.5 kW
Efficiency
= 80%
Heating area
= 62-101 m2*
Gas type
= NG or ULPG
Safety devices
Light to pilot, delayed ignition,
overheat switch, electronic flame
failure supervision, and combustion
chamber relief.
Ignition
Integrated sparker to pilot.
Installation considerations
Maximum flue height is 5.4 m.
Suitability
Suitable for living rooms and open
plan areas.
Temperature control
Thermostat control. Temperature
control range 7-32 °C.
Room size—smaller rooms will heat
up quickly, and due to the efficiency
of the appliance, the heater will turn
off once the set temperature has been
reached.
Recommended for a new build
installation into a false (mock)
chimney. It is not suitable for
retrofitting into an existing masonry
fireplace.
The lower temperature range is for
cooler climates where the room
temperature could fall below 7 °C.
Noise level: 37-45 dB(A)
Weight - 60 kg
®
Thermostat
controlled
Fan
Timer
Remote
control
Electronic
ignition
4.2 STARS
Child lock
SENSITIVE
CHOICE
SUPP OR T IN G
A S T H M A CA RE
* Will vary depending on geographical location in NZ
Premium metal frame outer dimensions
1155
538
668
538
643
1006ID
25
Standard metal frame outer dimensions
1110
845
1090
715
60
95
149
310
510
500
400
775
750
995
890
CL
190
440
1060
26 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
All dimensions are in mm.
Symmetry RDV3611 positioning
850 mm min.
Framing dimensions
The main points governing location are flueing
and warm air distribution. The Symmetry has
an integrated zero clearance box that isolates
the appliance from combustible materials. This
means it can be installed directly into a decorative
fireplace constructed from materials such as wood
or plaster.
250 MM SIDE CLEARANCE
If installing the Symmetry Heat Transfer Kit allow
an additional side clearance of 250 mm (per kit).
This clearance is required to ensure the ducting
does not come into contact with the fire.
250 m
m
0m
1100 -
m
95
m
915 mm
12
1830 mm
To ceiling
250 mm max.
1000
400
B Mantel depth at A - 400 mm (vertical
clearance)
m
m
MANTELS AND SURROUNDS
Mantels and surrounds, made of combustible
materials, are allowed provided they are outside
the minimum clearances shown.
400 mm min.
250 m
1125 m
The 400 mm side clearance includes side walls.
A Mantel height from top of glass
m
54
CORNER INSTALLATIONS
The diagram highlights the minimum dimensions
required if using the width, height, and depth of
the framing dimensions shown above it.
Clearances from combustibles - measured
from the edge of the glass
WHILE THE HEATER IS OPERATING
The appliance must not be installed where
curtains or other combustible materials could
come into contact with the heater. In some cases
curtains may need restraining. The clearances are
minimum clearances unless otherwise stated.
.
in
m
400
400
For every 50 mm of added mantel depth, there must be
an additional 100 mm of vertical clearance. For example;
a mantel depth (B) of 350 mm will require 600 mm (A) of
vertical clearance.
C Surround from side of glass
250 mm min.
D Surround projection at C - 250 mm
(side clearance)
250 mm max.
1
0
0
0
B
D
A
C
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 27
Symmetry RDV3611 frames and accessories
Black frame kit
Satin chrome frame kit
Black on black premium flat
frame kit
Code: R3601GL
Code: R3601SC
Code: R3602
Black inner and outer metal frame.
Satin chrome inner and outer metal
frame.
Flat black inner and outer metal
frame.
80
580
80
1252
120
Stainless on black premium
flat frame kit
R10
Granite frame kit
Inner frames only
Code: R3620
Codes:
Black inner
= 13621GL
Satin chrome inner = 13621SC
Code: R3603
Flat stainless steel inner, and black
outer metal frame.
Black granite surround. Supplied in
four pieces. Kit includes the black
inner frame.
Inner frame for frameless
installations.
Symmetry dress guard
Reflective side panel kit
Heat transfer kit 9 m
Code: R3610GL
Codes:
Brushed stainless = R3617
Mirrored finish = R3618
Code: R3626
Black integrated mesh, designed
to click into place over the fire—to
prevent from touching the surface
of the hot glass.
Enhances the flame picture of the
fire (fitted when fire is installed).
Transfers up to 1 kW of heat to
one additional room—one kit per
room.
Heat transfer kit - additional notes
Maximum of two kits can be connected to the unit. Grill provided in
the kit is a ceiling grill.
Ducting floor grill
Code: R3627
For installations where heat is being
transferred through the floor—
ordered in addition to the 9 m kit.
t Ceiling outlet: 160 x 160 mm
t Ducting: inner diameter 150 mm, outer diameter 200 mm
t Hanging chain for fan: Length is 2 m
If heat is being transferred through a floor grill instead of a ceiling
outlet the floor grill will need to be ordered in addition to the heat
transfer kit.
28 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Symmetry RDV3611 flueing options (most common)
Vertical termination with 45° bends
Vertical termination with 90° bends
Max. 5.4 m
Max. 5.4m
Restrictor position # 2
Restrictor position # 2
4.2 m
4.2 m
Restrictor position # 3
Restrictor position # 3
3.0 m
3.0 m
Restrictor position # 4
Restrictor position # 4
1.8 m
1.8 m
No restrictor
No restrictor
Min. 0.6 m
after bend
Min. 0.9 m
Min. 0.9 m
Max. 3.5 m
Max. 1.8 m
Horizontal termination with a 90° bend
Max. 1.2 m
Max. 5.4 m
Max
. Ho
rizo
ntal
=(6.0
3-Ve
Restrictor position # 3
rtica
l)/0
.52
4.2 m
Maximum number of bends
t Vertical termination with 45° bends - two
t Vertical termination with 90° bends - two
t Horizontal termination - one 90° bend
Inner flue clearance to combustibles
Minimum clearance from the inner flue to a
combustible material must be greater than 25 mm.
Horizontal runs of flue pipe
Horizontal pipe sections should be supported at
least every 1.2 m. Wall straps can be used for this
purpose.
Restrictor position # 4
2.4 m
No restrictor
tal
zon
ori
H
ax.
92
0.6
al/
rtic
The horizontal run of flue pipe MUST HAVE a rise
of 20 mm for every 1 m towards the flue terminal.
Never allow the horizontal pipe to run down
towards the flue terminal—potential fire hazard
due to heat becoming trapped in the flue.
e
=V
M
Min. 0.9 m
Min. 0.3 m Max. 0.9 m
Max. 3.5 m
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 29
Symmetry RDV3611 flue kits and components
310
325 - 440
310
435 - 550
Roof cowl
(high wind)
90 º elbow
1040
300 mm
pipe
230 mm pipe x 2
Wall terminal
1775
Flashing
kit
Wall strap
Interior wall
900 mm pipe
Flue pipe 1.2 m
Base
25
Flue kit horiz. short - A
Flue kit horiz. long - B
Flue kit vertical 3.6 m
Code
Code
Code
= R3660
= R3661
RDV3611 short horizontal flue
kit—635-750 mm frame to outside
wall.
RDV3611 long horizontal flue
kit—745-860 mm frame to outside
wall.
Contains; flue pipe 900 mm, elbow
90°, flue pipe 300 mm, horizontal
flashing kit, and wall terminal.
Contains; flue pipe 900 mm,
elbow 90 °, flue pipe 230 mm (x2),
horizontal flashing kit, and wall
terminal.
= R3665
RDV3611 3.6 m vertical flue kit.
Contains:
t Flue pipe 1.2 m (x3)
t Wall straps (x2)
t Roof cowl
Inner - aluminium
108
Outer - galvanised
165
108
165
RDV3611 flue elbow 90 °
RDV3611 flue elbow 45 ° (x2)
RDV3611 flue pipes
Code
Code
Codes:
150 mm
230 mm
300 mm
450 mm
600 mm
900 mm
1.2 m
= R3643
= R3642
Used to facilitate vertical and
horizontal flueing. Elbow swivels
360 ° at base. Angle not adjustable.
Offsets obstructions. Elbow swivels
360 ° at base. Angle not adjustable.
Kit contains two 45 ° bends.
Once joined effective length
reduces 35 mm to approximately
130 mm.
Once joined effective length
reduces 35 mm to approximately
73 mm.
Inner:
Outer:
Inner:
Outer:
aluminium
galvanised
30 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
aluminium
galvanised
= R3630
= R3631
= R3632
= R3633
= R3634
= R3635
= R3636
Pipe used to construct horizontal
and vertical flueing. Cannot be
cut to size. Once joined nominal
length reduces approx. 35 mm.
D
D
A
C
B
Flue extension
Elbow strap
Thru-wall plate interior
Codes:
75-175 mm
75-360 mm
Code
Code
= R3638
= R3639
= R3644
Flue support for elbow and offsets.
Used for extended straight lengths
of flue. Available in two lengths—
extending to 175 mm or 360 mm.
Inner:
Outer:
= R3645
Interior through-wall plate—
centres flue and ensures suitable
clearances from combustibles.
A = 171.5 mm
C = 304.8 mm
B = 279.4 mm,
D = 101.6 mm.
aluminium
galvanised
82
48.5
350 mm
338 mm
270
30
338 mm
11716 - Flashing Collar
252 mm
11715 - Flashing Box
Horizontal flashing kit
Wall strap
Horizontal wall terminal
Code
Code
Code
= R3646
Flashing components used to join
the internal flue to the outside
flue—to provide a weathertight
seal in horizontal flue installations.
Refer Horizontal Wall Terminal for
installed dimensions.
= R3647
Adjustable strap used in interior/
exterior installations to add lateral
support to the flue.
Provides a 50-200mm clearance to
combustible walls.
= R3650
Aluminium flue terminal required
for all horizontal installations.
Side profile image shows
dimensions with the horizontal
flashing kit added.
245.6 mm
325.6 mm
268 mm
Roof cowl
Flue restrictor
Code
Code
= R3651
Aluminium flue terminal required
for all vertical flue installations.
= 11516
Supplied with the unit.
Maintains efficiency by restricting
air flow through the unit as flue
length and flue pull increases.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 31
Symmetry RDV3611 ordering guide
1. Select gas type (engine)
Symmetry RDV3611 NG engine
RDV3611ETRN
Symmetry RDV3611 LPG engine
RDV3611ETRL
Supplied with the engine is the remote control and batteries, remote control mounting bracket, lintel spacers,
securing bracket and screws, flue restrictor, frame mouting screws, and log set.
2. Select frame option
Black inner and outer frame
R3601GL
Satin chrome inner and outer frame
R3601SC
Premium flat frame - black on black
R3602
Premium flat frame - stainless on black
R3603
Granite surround with black inner frame R3620
Black inner frame
13621GL* (for frameless installations)
Satin chrome inner frame
13621SC* ( for frameless installations)
* Only ordered if you are doing a frameless installation. Currently we do not sell the premium inner flat frame as
an option. This would need to be ordered as a spare part—contact Customer Services for more information.
3. Select flue kit and/or individual flue components
Flue kit horizontal short - A
(635-750 mm frame to outside wall)
R3660 (flue pipe: 900 mm, 300 mm)
Flue kit horizontal long - B
(745-860 mm frame to outside wall)
R3661 (flue pipe: 900 mm, 230 mm x 2)
Flue kit vertical 3.6 m
R3665 (flue pipes, cowl, and wall straps)
Horizontal flashing kit
R3646 (flue collar and flashing box)
Wall terminal
R3650
Roof cowl
R3651
Flue elbow 90°
R3643
Flue elbow 45° (two in a kit)
R3642
32 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Flue pipe 150 mm
Flue pipe 230 mm
Flue pipe 300 mm
Flue pipe 450 mm
Flue pipe 600 mm
Flue pipe 900 mm
Flue pipe 1.2 m
R3630 Cannot be cut to size. Once
R3631 joined length reduces by
approximately 35 mm.
R3632
R3633
R3634
R3635
R3636
Flue extension 75-175 mm
Flue extension 75-360 mm
R3638
R3639
Thru-wall plate interior
R3645
Wall strap
R3647
Elbow strap
R3644
4. Select optional accessories
Black mesh dress guard
R3610GL
Reflective side panel kit - brushed
stainless steel
R3617
Reflective side panel kit -mirrored finish R3618
Ducting kit 9 m (one kit per room)
R3626
Ducting floor grill (and transition boot)
R3627
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 33
Neo Inbuilt/Premium Classic specification
Burning log effect inbuilt gas fire
with glass front and convection fan.
Different frame options available.
Convection fan
Fan forced 2-speed convection fan
(low and high). Heat is distributed
from the top of the appliance.
Flue: Mock chimney
Natural draft flue. Inner 100 mm, outer
150 mm. Appliance must be installed
with a Rinnai flue system.
Data plate
Inside appliance on the front left hand
side.
Power consumption and electrical
supply
High
= 50 W
Standby = < 3 W
Gas connection
½ “ BSPT. The gas supply terminates
inside the heater at the lower front
right hand side of the appliance.
Choose from either the ETR model,
lets you preset the warmth to come
on at any time, or the manual control
model for push button operation.
Ignition
Continuous spark electronic ignition.
Specification summary
Input
= 14-30 MJ/h*
Output
= 2.98-6.94 kW*
Efficiency
= 80%
Heating area
= 69-107 m2**
Gas type
= NG or ULPG
Installation considerations
The Neo draws air for combustion
from the room. Adequate ventilation
must be calculated and provided by
the gasfitter, as per AS/NZS 5601.1
Suitability
Suitable for masonry installations
and installations into a mock (false
chimney). Ideally suited to living
rooms and open plan areas.
Noise level: 37-45 dB(A)
This heater has a 1.5 m power cord
with a 3-pin plug supplied. The
standard electrical connection is to
the rear left of the appliance.
Safety devices
Overheat switch, electrical fuse, and
flame failure sensing system.
Temperature control
t Manual models
Manual control on the unit
t
Flue: Masonry
Rinnai recommends the use of a Rinnai
flexiliner flue system (Ø 100 mm).
Burn media
Driftwood log set comes as standard.
ETR models
Thermostat temperature control,
range 7-32 °C. The lower temp.
range is for cooler climates where
rooms could fall below 7 °C.
Weight - 60 kg
ETR model
Manual model
Thermostat Timer
controlled
Remote Electronic Child lock
control
ignition
Electronic
ignition
Fan
Fan
* Will vary according to gas type, refer website for a full breakdown between NG and LPG
Inbuilt masonry
** Will vary depending on geographical location in NZ
Inbuilt mock chimney
A
B
4.1 STARS
Manual
control
C
D
A
F
A
= 865 mm
B
= 660 mm
C
= 359 mm
C
D
A
B
F
D = 62 mm
J
E
I
Premium classic dimensions
865
= 660 mm
C
= 363 mm
= 62 mm
E
= 795 mm
= 589 mm
F
= 650 mm
H = 305 mm
G
= 280 mm
H
= 305 mm
I
= 45 mm
J
= 240 mm
= 691 mm
F
I
= 45 mm
J
= 235 mm
J
E
I
G
Please note:
t Above dimensions include the frame
t H, I, J dimensions refer to the gas connection
436
590
359
703
B
D
E
H
H
34 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
= 865 mm
Neo Inbuilt/Premium Classic positioning
Inbuilt masonry
Inbuilt mock chimney
695 mm
800 mm
H-height 600 mm
650 mm
D-depth
370 mm
W-width
370 mm
Clearances from combustibles
WHILE THE HEATER IS OPERATING (FROM EDGE OF FRAME)
The appliance must not be installed where
curtains or other combustible materials could
come into contact with the heater. In some cases
curtains may need restraining. The clearances
stated are minimum clearances unless otherwise
stated.
Above
Sides
In front
= 400 mm (1000 mm to ceiling)
= 400 mm (includes side walls)
= 1000 mm
400 mm
Framing dimensions
The main points governing location are flueing
and warm air distribution. The Neo Inbuilt/
Premium Classic models require a zero clearance
box (p. 36). This is a box that isolates the appliance
from combustible materials. This means it can
be installed directly into a decorative fireplace
constructed from materials such as wood or
plaster.
40
0m
m
m
m
00
40
0m
10
m
MANTELS AND SURROUNDS (FROM EDGE OF GLASS)
Mantels and surrounds, made of combustible
materials, are allowed providing they are outside
the minimum clearances shown.
A Mantel height from top of glass
400 mm min.
B Mantel depth at A - 400 mm (vertical
clearance)
250 mm max.
For every 50 mm of added mantel depth, there must be
an additional 100 mm of vertical clearance. For example;
a mantel depth (B) of 350 mm will require 600 mm (A) of
vertical clearance.
C Surround from side of glass
200 mm min.
D Surround projection at C - 200 mm
(side clearance)
250 mm max.
B
F
D
A
E
E
Minimum mantel height from floor
(when heater is mounted on the floor)
910 mm max.
F
Minimum width for surround
915 mm min.
C
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 35
Neo Inbuilt/Premium Classic frames and ZCB
Premium classic black frame
with silver dress guard
Premium classic black frame
with bronze dress guard
Stainless inner, black outer
frame
Code: R2323
Code: R2324
Code: R2325
Comes with a black inner frame.
Comes with a black inner frame.
Stainless steel inner and black outer
frame, plus glass dress guard
Stainless inner/trims, black
outer frame
Stainless inner and outer
frame
Black inner and outer frame
Code: R2326
Code: R2327
Code: R2328
Stainless steel inner and trims, and
black outer frame, plus glass dress
guard.
Stainless steel inner and outer
frame, plus glass dress guard.
Black inner and outer frame, plus
glass dress guard.
81
Ø 146
790
Neo zero clearance box (ZCB)
Installed flush with the drywall
surface.
45
Isolates the appliance from
combustible materials. Required for
all mock chimney installations—
includes the flue spigot (requires
assembly).
650
Code: R2340
86
36 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Ø 53
361
Neo Inbuilt/Premium Classic flueing options
Masonry - without flexiliner flue
Masonry - with flexiliner flue
Flue component:
- Flue cowl (R1760-2)
Flue components:
- Flexiliner flue kit (R1756)
Inbuilt mock chimney - direct and offset
Inbuilt mock chimney - offset wall penetration
A - direct flue (straight vertical)
B - offset flue (45° bends)
Flue components:
- Zero clearance flue kit
(R1762Z)
Flue components - A:
- Zero clearance flue kit (R1762Z)
- Wall penetration kit
(R1766)
Flue components - B:
- Zero clearance flue kit
(R1762Z)
- 45° bend kit (R1764) x 2
Masonry installations
Rinnai recommends the use of a flexiliner flue
system (flexi Ø 100 mm) as it ensures optimum
performance of the appliance. Installation without
a flexiliner flue is permissible as long as the
chimney is checked for soundness and ability to
achieve a good draw. If in doubt it pays to install
the flexiliner flue.
Flue length and maximum number of bends
Minimum flue length
This is required to ensure adequate draw and
prevent spill-back of combustion products—can
cause the safety sensors to shut down the fire.
Mock chimney (zero clearance) flueing
Natural draft flue double skin flue. For installations
into a combustible opening a Rinnai zero
clearance box and flue kit are mandatory.
t Min. vertical length
3.6 m (or three lengths of flue)
Flue dimensions: Inner 100 mm, outer 150 mm.
There must be a 25 mm clearance from the inner
flue to any combustible surface.
t Min. flue length before any bends or offsets
1.2 m (or one length of flue)
Maximum flue length
Rinnai recommends a maximum flue length of
8 m, with a maximum of two 45° bends.
Flue construction
Inner - stainless steel
Outer - galvanised
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 37
Neo Inbuilt/Premium Classic flue components
R1760-2 Flue cowl 100 mm
R1760-3 Flexi flue chimney
flashing plate
R1764 flue bend
Exterior wall plate including
45° extension (400 x 340 mm)
150-250 mm adjustable
slip pipe
Interior wall plate
Pipe extension
with bend
R1760-6 Aluminium flexi flue 3.6 m
660-760 mm
10469 Guide rails
(sit either side of spigot guide)
11954 Spigot guide
11956 Spigot assembly flexi
Neo flexiliner flue kit 3.6 m
Code: R1756
For installation into an existing
masonry fireplace. Allows the fire
to perform more effectively by
achieving a better draw. Includes;
flue cowl, chimney flashing plate,
flexiliner, and flue spigot.
Wall penetration kit galv.
Flexiliner flue extension
Code: R1766
Code: R1761
For internal to external applications
(multi-storey dwelling). Used in
conjunction with the ZC flue kit.
Minimum of one length of flue pipe
required before using this kit.
Extension for flues exceeding 3.6 m.
Comes as a 2 m length and extends
to 3.6 m.
Stainless steel
inner 1.22 m
Galvanised
outer 1.2 m
Stainless steel
inner 1.2 m
Stainless steel
outer 1.2 m
R1760-2 Flue cowl 100 mm
R1762-2 Top spacer bracket
R1762-3 Galv. slip liner 400 mm
R1762-4 Galv. outer 1.2 m
(Ø 150 mm)
Flue extension galvanised
Flue extension stainless steel
Code: R1763Z
Code: R1763SS
Galvanised flue extension for flues
exceeding 3.6 m.
Stainless steel flue extension.
Recommended for external
penetrations through the roof, for
locations close to the sea, where
traditional flueing may rust.
R1762-5 Stainless steel inner (x3)
(Ø 100 mm)
R1762-4 Galv. outer 1.2 m
(Ø 150 mm)
R1762-4 Galv. outer 1.2 m
(Ø 150 mm)
85 mm
R1762Z-12 ZC adaptor
85 mm
R1762-9 Stainless clamp sleeve
Zero clearance flue kit galv.
45° bend galvanised (1)
Neo flexiliner flue spigot
Code: R1762Z
Code: R1764
Code: R1756-5F
Galvanised zero clearance flueing
(3.6 m) for fires installed into
combustible openings.
45° bend used for offset
applications. Can only be used to
offset the flue. Max. of two per
installation. Inner is stainless steel
and outer is galvanised.
If there is an existing flexiliner flue
already in place from a previous
installation (in good condition), the
flexiliner flue spigot can be ordered
as a separate component. Requires
assembly.
Centre to centre = 150 mm.
38 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Neo Inbuilt/Premium Classic ordering guide
1. Select gas and control type required
Neo ETR NG engine
RIB2311ETRN
Neo ETR LPG engine
RIB2311ETRL
Neo manual control NG engine
RIB2311MN
Neo manual control LPG engine
RIB2311ML
The only difference between the ETR and manual is the remote. Supplied with the engine is the gas connection,
frame mounting screws (pre-installed into the engine mounting brackets), and log set.
2. Select frame option
Premium Classic black frame with silver
dress guard
R2323
Premium Classic black frame with
bronze dress guard
R2324
Stainless steel inner, black outer frame
R2325
Stainless inner/trims, black outer frame R2326
Stainless inner and outer frame
R2327
Black inner and outer frame
R2328
3. Determine flueing option, and select flue kits and/or flue components
Masonry flueing
Neo flexiliner flue kit 3.6 m
R1756 (includes flue spigot)
Flexiliner flue extension
R1761 (for flues exceeding 3.6 m)
Neo flexiliner flue spigot
R1756-5F (refer note on p. 38)
Neo inbuilt zero clearance box
R2340
Zero clearance flue kit galv. 3.6 m
R1762Z
ZC flue extension galvanised 1.2 m
ZC flue extension stainless 1.2 m
R1763Z
R1763SS
Wall penetration kit galvanised
R1766
45° bend galvanised
(inner, outer and spacer)
R1764
Inbuilt mock chimney
Where bends are required—
need two per installation
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 39
Neo Freestanding specification
Burning log effect freestanding gas
fire with glass front and convection
fan. Different frame options available.
Choose from either the ETR model,
lets you preset the warmth to come
on at any time, or the manual control
model for push button operation.
Specification summary
Input
= 14-30 MJ/h*
Output
= 2.98-6.94 kW*
Efficiency
= 80%
Heating area
= 69-107 m2**
Gas type
= NG or ULPG
Convection fan
Fan forced 2-speed convection fan
(low and high). Heat is distributed
from the top of the appliance.
Power consumption and electrical
supply
High
= 50 W
Standby = < 3 W
Data plate
Inside appliance on the front left hand
side.
This heater has a 1.5 m power cord
with a 3-pin plug supplied. The
standard electrical connection is to
the rear left of the appliance.
Gas connection
½ “ BSPT. The gas supply terminates
inside the heater at the lower front
right hand side of the appliance.
Safety devices
Overheat switch, electrical fuse, and
flame failure sensing system.
Ignition
Continuous spark electronic ignition.
Temperature control
t Manual models
Manual control on the unit
Installation considerations
The Neo draws air for combustion
from the room. Adequate ventilation
must be calculated and provided by
the gasfitter, as per AS/NZS 5601.1
Suitability
Suitable for freestanding installations.
Ideally suited to living rooms and open
plan areas.
Burn media
Driftwood log set comes as standard.
t
Noise level: 37-45 dB(A)
Flue
Natural draft flue. Inner 100 mm, outer
150 mm. Appliance must be installed
with a Rinnai flue system.
ETR model
ETR models
Thermostat temperature
control, range 7-32 °C. The
lower temperature range is for
cooler climates where the room
temperature could fall below 7 °C.
Weight - 60 kg
Manual model
Thermostat Timer
controlled
Remote Electronic Child lock
control
ignition
Electronic
ignition
Fan
Fan
* Will vary according to gas type, refer website for a full breakdown between NG and LPG
Freestanding console
** Will vary depending on geographical location in NZ
Freestanding plinth
865
760
4.1 STARS
Manual
control
363
62
760
363
865
837
62
837
235
280
215
305
305
Please note: Above dimensions include the frame—all dimensions are in mm.
40 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
712
865
280
140
712
865
235
Neo Freestanding positioning
Clearances from combustibles - from edge of
frame
WHILE THE HEATER IS OPERATING
The appliance must not be installed where
curtains or other combustible materials could
come into contact with the heater. In some cases
curtains may need restraining. The clearances are
minimum clearances unless otherwise stated.
Above
Sides
In front
= 400 mm
= 400 mm (includes side walls)
= 1000 mm
* The 400 mm side clearance includes side walls.
Neo Freestanding frames and outer panel kits
Stainless inner, black outer
frame
Stainless inner/trims, black
outer frame
Stainless inner and outer
frame
Code: R2325
Code: R2326
Code: R2327
Stainless steel inner and black outer
frame, plus glass dress guard
Stainless steel inner and trims, and
black outer frame, plus glass dress
guard.
Stainless steel inner and outer
frame, plus glass dress guard.
Black inner and outer frame
Freestanding console kit
Freestanding plinth kit
Code: R2328
Code: R2341GL
Code: R2342GL
Black inner and outer frame, plus
glass dress guard.
Black flat pack console
freestanding kit—includes the flue
spigot. Assembly required.
Black flat pack plinth freestanding
kit—includes the flue spigot.
Assembly required.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 41
Neo Freestanding flueing options
Freestanding straight vertical
Freestanding with offset wall penetration
Flue components:
- Freestanding galaxy black flue kit (R1762GL), or
- Freestanding brushed stainless steel flue kit (R1762BS)
Flue components:
- Freestanding galaxy black flue kit (R1762GL), or
- Freestanding brushed stainless steel flue kit (R1762BS)
If you wanted to offset the
he flue in the
roof (see smaller image below)
you would use 45° bend kits
(R1764 x2)
- Wall penetration kit
black (R1766GL), or
- Wall penetration kit
galvanised (R1766)
Difference in flue lengths
For our inbuilt range our flue lengths are all 1.2 m. For our freestanding flues, those that are powder
coated (galaxy black and brushed stainless steel) flue lengths are 1 m. An easy way to remember is:
t unpainted 1.2 m
t painted 1 m
Flue length and maximum number of bends
Minimum flue length
This is required to ensure adequate draw and prevent spill-back of combustion products—can cause the
safety sensors to shut down the fire.
t Minimum flue length before any bends or offsets 1 m (or one length of flue)
t Minimum vertical length 3.6 m (or three lengths of flue)
Maximum flue length
Rinnai recommends a maximum flue length of 8 m, with a maximum of two 45° bends.
42 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Neo Freestanding flue components
R1760-2 Flue cowl 100 mm
R1762-2 Top spacer bracket
R1760-2 Flue cowl 100 mm
R1762-2 Top spacer bracket
R1762-3 Galvanised slip liner 400 mm
R1762-3 Galvanised slip liner 400 mm
R1762-4 Galvanised outer 1.2 m (Ø 150 mm)
R1762-4 Galvanised outer 1.2 m
R1762GL-6 FS ceiling plate galaxy black
(250 x 250 mm)
R1762BS-6 FS ceiling plate brushed stainless
(250 x 250 mm)
R1762BS-7 FS upper heat shield brushed stainless 1 m
(Ø 145 mm, one swage)
R1762GL-7 FS upper heat shield black 1 m
(Ø 145 mm, one swage)
R1762-5 Flue piper inner stainless steel inner 1.2 m
(Ø 100 mm)
R1762-5 Flue piper inner stainless steel inner 1.2 m
(Ø 100 mm)
R1762BS-8 FS lower heat shield brushed stainless 1 m
(Ø 145 mm, two swages)
R1762GL-8 FS lower heat shield black 1 m
(Ø 145 mm, two swages)
R1760-9 Stainless steel clamp sleeve
R1760-9 Stainless steel clamp sleeve
Freestanding galaxy black flue kit 3.6 m
Freestanding brushed stainless flue kit 3.6 m
Code: R1762GL
Code: R1762BS
Galaxy black powder coated freestanding flue kit. Black
sections of the flue equate to2 m of flue.
Brushed stainless freestanding flue kit. Brushed stainless
sections of the flue equate to 2 m of flue.
R1764 45° galvanised flue bend
R1764 45° galvanised flue bend
Galvanised exterior wall plate including 45°
extension (400 x 340 mm)
Galvanised exterior wall plate including 45°
extension (400 x 340 mm)
150-250 mm adjustable slip pipe
150-250 mm adjustable slip pipe
Galaxy black interior wall plate
Galvanised interior wall plate
Galaxy black pipe
extension with bend
660-670 mm
Galvanised pipe
extension with bend
660-670 mm
Wall penetration kit galaxy black
Wall penetration kit galvanised
Code: R1766GL
Code: R1766
For internal to external applications (multi-storey
dwelling). Used in conjunction with the freestanding flue
kit. Minimum of one length of flue pipe required before
using this kit.
For internal to external applications (multi-storey
dwelling). Used in conjunction with the freestanding flue
kit. Minimum of one length of flue pipe required before
using this kit.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 43
Stainless steel
inner 1.22 m
(Ø 100 mm)
Galvanised
outer 1.2 m
(Ø 150 mm)
Stainless steel
inner 1.2 m
(Ø 100 mm)
Stainless steel
outer 1.2 m
(Ø 150 mm)
Stainless steel
inner 1 m
(Ø 100 mm)
Galaxy black
outer 1 m
(Ø 145 mm)
Flue extension galvanised
Flue extension stainless steel
Flue extension galaxy black
Code: R1763Z
Code: R1763SS
Code: R1763GL
Galvanised flue extension for flues
exceeding 3.6 m.
Stainless steel flue extension.
Recommended for external
penetrations through the roof, for
locations close to the sea where
traditional flueing may rust.
Powder coated galaxy black
internal flue extension.
Stainless steel
inner 1 m
(Ø 100 mm)
Brushed stainless
outer 1 m
(Ø 145 mm)
85 mm
85 mm
85 mm
85 mm
Flue extension brushed SS
45° bend galvanised (1)
45° bend
d galaxy
gala black (1)
Code: R1763BS
Code: R1764
Code: R1765GL
Brushed stainless steel internal flue
extension.
45° bend used for offset
applications. Can only be used to
offset the flue. Max. of two per
installation. Inner is stainless steel
and outer is galvanised.
45° black bend used for offset
applications. Can only be used to
offset the flue. Max. of two per
installation. Inner is stainless steel
and outer is powder coated black.
Centre to centre = 150 mm.
Centre to centre = 150 mm.
Comes with a protective plastic
coating on inner and outer
component.
44 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Neo Freestanding ordering guide
1. Select gas and control type required
Neo ETR NG engine
RIB2311ETRN
Neo ETR LPG engine
RIB2311ETRL
Neo manual control NG engine
RIB2311MN
Neo manual control LPG engine
RIB2311ML
The only difference between the ETR and manual is the remote. Supplied with the engine is the gas connection,
frame mounting screws (pre-installed into the engine mounting brackets), and log set.
2. Select frame option
Stainless steel inner, black outer frame
R2325
Stainless inner/trims, black outer frame R2326
Stainless inner and outer frame
R2327
Black inner and outer frame
R2328
3. Select freestanding kit (outer panels for engine)
Flat pack console freestanding kit with
spigot
Flat pack plinth freestanding kit with
spigot
R2341GL
R2342GL
4. Determine flueing option, and select flue kits and/or flue components
Flue kit freestanding galaxy black 3.6 m
Flue kit freestanding brushed SS 3.6 m
R1762GL
R1762BS
Flue extension galvanised 1.2 m
Flue extension stainless steel 1.2 m
Flue extension galaxy black 1 m
Flue extension brushed SS 1 m
R1763Z
R1763SS
R1763GL
R1763BS
Wall penetration kit galvanised
Wall penetration kit galaxy black
R1766
R1766GL
45° bend galvanised
45 ° bend galaxy black
R1764
R1765GL
Where bends are required—
need two per installation
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 45
Compact 2 specification
Inbuilt radiant/convector, glass
fronted, ceramic gas fire with forced
convection and natural draft flue
system. Heat is distributed from the
top of the appliance. Different frame
options available.
Specification summary
Input
= 9-25 MJ/h
Output
= 1.6-5 kW
Efficiency
= 73%
Heating area
= 50-77 m2*
Gas type
= NG or ULPG
Data plate
Inside appliance on the front right
hand side panel.
Flue: Mock chimney
Natural draft flue. Appliance must be
installed with a Rinnai flue system.
Gas connection
½ “ BSPF male flare—enters from the
rear of the appliance, refer diagram
below.
Power consumption and electrical
supply
High
= 20 W
Standby = 0 W
Ignition
Continuous spark electronic ignition.
This heater has a 1.5 m power cord with
a 3-pin plug supplied. The electrical
connection can exit the appliance
from the lower left or right hand side,
or from the rear of the heater.
Installation considerations
The Compact 2 draws air for
combustion from the room. Adequate
ventilation must be calculated and
provided by the gasfitter, as per
AS/NZS 5601.1
Safety devices
Flame failure thermocouple, overheat
switch (bi-metal strip), fan delay, and
power failure protection.
Noise level: 49 dB(A)
Weight: 39 kg
Suitability
Suitable for masonry installations
and installations into a mock (false
chimney). Ideally suited to living
rooms and open plan areas.
Operation
Push button to light pilot and burners
(low, medium, high).
Burn media
Ceramic log set comes as standard.
Flue: Masonry
Rinnai recommends the use of a Rinnai
flexiliner flue system ( flexi Ø 100 mm).
Convection fan
Convection fan tangential 2-speed.
Electronic
ignition
Fan
2.8 STARS
Manual
control
* Will vary depending on geographical location in NZ
All dimensions are in mm.
25
750
227
45
528
645
310
582
43
79
46 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
280
Compact 2 positioning
Framing dimensions
The main points governing location are flueing
and warm air distribution. The Compact 2 requires
a zero clearance box (p. 48). This is a box that
isolates the appliance from combustible materials.
This means it can be installed directly into a
decorative fireplace constructed from materials
such as wood or plaster.
Inbuilt masonry
Inbuilt mock chimney
595-700 mm
685 mm
H-height 550-630 mm
615 mm
D-depth
380 mm
W-width
360 mm
Clearances from combustibles (from edge of frame)
WHILE THE HEATER IS OPERATING
The appliance must not be installed where
curtains or other combustible materials could
come into contact with the heater. In some cases
curtains may need restraining. The clearances are
minimum clearances unless otherwise stated.
Above
Sides
In front
80 mm
For inbuilt mock chimney installations, the total
depth MUST also include the thickness of the
external cladding as the zero clearance box MUST
BE installed flush with the cladding surface to
ensure alignment of the flue.
180 m
m
180 m
m
= 80 mm
= 180 mm (includes side walls)
= 1000 mm
MANTELS AND SURROUNDS
Mantels and surrounds, made of combustible
materials, are allowed providing they are outside
the minimum clearances shown.
A Mantel height from edge of frame
80 mm min.
B Mantel depth at A - 80 mm (vertical
clearance)
150 mm max.
Side wall
For every 50 mm of added mantel depth, there must be
an additional 100 mm of vertical clearance. For example;
a mantel depth (B) of 200 mm will require 180 mm (A) of
vertical clearance.
C Surround from side of glass
80 mm min.
E
A
B
C
D
D Surround projection at C - 80 mm (side 250 mm max.
clearance)
E
Clearance to side wall
180 mm
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 47
Compact 2 frames and zero clearance box
Traditional black
frame
Stainless inner,
black outer frame
Stainless inner and
outer frame
Black inner and
outer frame
Code: R2525
Code: R2527
Code: R2528
Stainless steel inner and
black outer frame, plus
glass dress guard.
Stainless steel inner and
outer frame, plus glass
dress guard.
Black inner and outer
frame, plus glass dress
guard.
Code: R2524
Matt black steel frame.
(275)
(99)
146
374
680
Compact 2 zero clearance box
Zero clearance box (ZCB) that isolates the
appliance from combustible materials.
610
Code: R2520
Required for all mock chimney installations—
includes flue spigot.
53
45
Installed flush with drywall.
65 80
48 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Compact 2 flueing options
Masonry - without flexiliner flue
Masonry - with flexiliner flue
Flue component:
- Flue cowl (R1760-2)
Flue components:
- Flexiliner flue kit (R1758)
Inbuilt mock chimney - direct and offset
Inbuilt mock chimney - offset wall penetration
A - direct flue (straight vertical)
B - offset flue (45° bends)
Flue components:
- Zero clearance flue kit
(R1762Z)
Flue components - A:
- Zero clearance flue kit (R1762Z)
- Wall penetration kit
(R1766)
Flue components - B:
- Zero clearance flue kit
(R1762Z)
- 45° bend kit (R1764) x 2
Masonry installations
Rinnai recommends the use of a flexiliner flue
system (flexi Ø 100 mm) as it ensures optimum
performance of the appliance. Installation without
a flexiliner flue is permissible as long as the
chimney is checked for soundness and ability to
achieve a good draw. If in doubt it pays to install
the flexiliner flue.
Flue length and maximum number of bends
Minimum flue length
This is required to ensure adequate draw and
prevent spill-back of combustion products—can
cause the safety sensors to shut down the fire.
Mock chimney (zero clearance) flueing
Natural draft flue double skin flue. For installations
into a combustible opening a Rinnai zero
clearance box and flue kit are mandatory.
t Min. vertical length
3.6 m (or three lengths of flue)
Flue dimensions: Inner 100 mm, outer 150 mm.
There must be a 25 mm clearance from the inner
flue to any combustible surface.
t Min. flue length before any bends or offsets
1.2 m (or one length of flue)
Maximum flue length
Rinnai recommends a maximum flue length of
8 m, with a maximum of two 45° bends.
Flue construction
Inner - stainless steel
Outer - galvanised
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 49
Compact 2 flue components
R1760-2 Flue cowl 100 mm
R1760-3 Flexi flue chimney
flashing plate
R1764 flue bend
Exterior wall plate including
45° extension (400 x 340 mm)
150-250 mm adjustable
slip pipe
Interior wall plate
Pipe extension
with bend
R1760-6 Aluminium flexi flue 3.6 m
660-760 mm
R1758-5F Flexi flue spigot
adaptor
Compact flexiliner flue kit
3.6 m
Code: R1758
For installation into an existing
masonry fireplace. Allows the fire
to perform more effectively by
achieving a better draw. Includes;
flue cowl, chimney flashing plate,
flexiliner, and flue spigot adaptor.
Wall penetration kit galv.
Flexiliner flue extension
Code: R1766
Code: R1761
For internal to external applications
(multi-storey dwelling). Used
in conjunction with the zero
clearance flue kit. Minimum of one
length of flue pipe required before
using this kit.
Extension for flues exceeding 4 m.
Comes as a 2 m length and extends
to 3.6 m.
Stainless steel
inner 1.22 m
(Ø 100 mm)
Galvanised
outer 1.2 m
(Ø 150 mm)
Stainless steel
inner 1.2 m
(Ø 100 mm)
Stainless steel
outer 1.2 m
(Ø 150 mm)
R1760-2 Flue cowl 100 mm
R1762-2 Top spacer bracket
R1762-3 Galv. slip liner 400 mm
R1762-4 Galv. outer 1.2 m
(Ø 150 mm)
Flue extension galvanised
Flue extension stainless steel
Code: R1763Z
Code: R1763SS
Galvanised flue extension for flues
exceeding 3.6 m.
Stainless steel flue extension.
Recommended for external
penetrations through the roof, for
locations close to the sea where
traditional flueing may rust.
R1762-5 Stainless steel inner (x3)
(Ø 100 mm)
R1762-4 Galv. outer 1.2 m
(Ø 150 mm)
R1762-4 Galv. outer 1.2 m
(Ø 150 mm)
85 mm
R1762Z-12 ZC adaptor
85 mm
R1762-9 Stainless clamp sleeve
Zero clearance flue kit galv.
45° bend galvanised (1)
Compact flexiliner flue spigot
Code: R1762Z
Code: R1764
Code: R1758-5F
Galvanised zero clearance flueing
for fires installed into combustible
openings.
45° bend used for offset
applications. Can only be used to
offset the flue. Max. of two per
installation. Inner is stainless steel
and outer is galvanised.
If there is an existing flexiliner flue
already in place from a previous
installation (in good condition), the
flexiliner flue spigot can be ordered
as a separate component. Requires
assembly.
Centre to centre = 150 mm.
50 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Compact 2 ordering guide
1. Select gas type (engine)
Compact 2 NG engine
RIBF2N
Compact 2 LPG engine
RIBF2L
Supplied with the engine is the ½ “ BSPF male flare nut, adhesive back foam sealing strip, frame mounting screws
(pre-installed into the engine mounting brackets), and the log set.
2. Select frame option
Traditional black frame
R2524
Black outer and stainless steel inner frame R2525
Stainless steel inner and outer frame
R2527
Black outer and inner frame
R2528
3. Determine flueing option, and select flue kits and/or flue components
Masonry flueing
Compact flexiliner flue kit 3.6 m
R1758 (includes flue adaptor)
Flexiliner flue extension
R1761 (for flues exceeding 3.6 m)
Compact flexiliner flue spigot*
R1758-5F
* If there is an existing Rinnai flexiliner flue already in place from a previous installation, in good condition, the
flexiliner flue spigot can be ordered as a separate component.
Inbuilt mock chimney
Compact inbuilt zero clearance box
R2520
Zero clearance flue kit galv. 3.6 m
R1762Z
ZC flue extension galvanised 1.2 m
ZC flue extension stainless 1.2 m
R1763Z
R1763SS
Wall penetration kit galvanised
R1766
45° bend galvanised
(inner, outer and spacer)
R1764
Where bends are required—
need two per installation
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 51
Impression outdoor fire specification
Data plate
Left hand side of burner under granite.
Open radiant/convector outdoor gas
fire with manual control.
Specification summary
Input
= 25-45 MJ/h
Output
= 12 kW
Gas type
= LPG as standard*
Gas control
Gas control valve consisting of an
inlet connection, Piezo igniter,
thermocouple flame failure and
manual control knob.
Safety devices
t Light to pilot
t Flame failure
Weight
Burner assembly = 20 kg
Body assembly
= 30 kg*
* Single sided cabinet
Ignition
Intermittent pilot.
* Can be converted to NG with a LPGNG conversion kit
Installation considerations
Cannot be installed into an exterior
wall.
Suitability
Suitable as a permanent fixed heating
appliance in outdoor areas only.
Installations using a 9 kg LPG bottle
connection can be completed by the
homeowner.
NOT SUITABLE for installation into an
exterior wall of a dwelling.
Installations for fixed NG and LPG
connections MUST BE completed by a
licensed gasfitter.
Burn media
Ceramic stones come as standard.
Operation
Push button control.
550 mm
Flue - no flue required.
1080 mm
52 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
400 mm
197 mm
470 mm
121 mm
1170 mm
Impression outdoor fire positioning
Appliance location and surround dimensions
The Rinnai Impression outdoor fire must be installed
as a permanent fixture in an outdoor area. It must
not be installed into an exterior wall of a dwelling.
Considerations such as trees, neighbours,
protection from direct rain and sea spray, openable
windows, gas supply, and clearances from
combustibles will influence where you can position
the appliance. Location will also be dependent on
the type of unit purchased and if installing into a
combustible cavity.
There are a number of different framing options
available, all of which have different installation
dimensions—too many to list here. For information
on enclosure and framing dimensions, please refer
to the operation and installation manual available on
the Rinnai website.
1m
1m
300mm
300mm
1m
General clearances for the freestanding unit
Clearances from combustibles
Clearance required
Below eaves, balconies or other
projections (A)
1000 mm
rh
r Ove
Roof o
A
If the projection is a shade cloth or material awning
then this is deemed a combustible material with a
recommended clearance of 1500 mm.
C
From the ground or other surface 100 mm cabinet
(B)
700 mm freestanding
Ground level to bottom of fireplace. For optimal viewing
while standing or sitting it is recommended to position
between 600-800 mm from the ground. If installing
the cabinet option at a lower level, remember to allow
enough room for the gas connection underneath.
Walls (C), side of unit to side wall
500 mm
Gas and electricity meters
1000 mm
Drain or soil pipe
150 mm
Openable windows and doors
500 mm
ang
Additional structure or sidewall
Structure
B
General clearances for the inbuilt unit
From an openable window, door or non-mechanical
air inlet, or any other opening into a building, with the
exception of sub-floor ventilation.
Mechanical air inlet (e.g. air
conditioning unit)
2000 mm
Mantels or protrusions cannot be installed above
the unit if any part of the surround is made of
combustible material. If installing into a noncombustible surround the mantel/protrusion must
also be non-combustible.
Fixed objects such as outdoor furniture, umbrellas,
and plants should be at least one metre away from
the unit when it is in operation.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 53
Impression outdoor fire accessories
Glass bi-fold door assembly
LPG-NG conversion kit
Console base module
Code: R2612
Code: R2613
Code: R2632
Offers wind protection when
the unit is on, and when not in
use, protection from wind, rain,
and nesting animals. Suitable for
cabinet installations using cladding
and finishes that can withstand
temperatures up to 150 °C.
Conversion can occur at the time
of installation of the fire, or as a
retrofit installation.
Allows for a perfect fit of the
Impression outdoor fire. The metal
modules can be stacked to form a
number of different configurations.
Conversion must be completed by
a licensed gasfitter.
Width - 1700 mm, height - 700 mm,
depth - 470 mm.
image unavailable
Console spacer module
Console door module
Metal lintel kit
Code: R2633 (sold as a pair)
Code: R2631
Code: R2629
Designed to act as side units
or legs. The Impression will sit
perfectly between the spacers,
giving the installation a clean flush
look.
Designed to be installed into the
base module to provide easy access
to either a storage area or to 9 kg
gas bottles.
Additional metal lintel.
Height - 560 mm, width - 250 mm,
depth - variable (dependent on
cladding).
54 ¦ Rinnai Gas Fireplaces Specification Guide 04-14
Can be customised with a hand slot
so the door can be lifted in and out.
For enclosure designs where
clearance from the first metal lintel
is less than 500 mm.
Impression outdoor fire ordering guide
1. Select Impression model
Single sided cabinet LPG
ROF4501MDBL
Freestanding burner assembly LPG
ROF4500MDBL
Single sided cabinet: Burner assembly, frame trim kit components, stainless steel weather cover, granite cover
and trims, ceramic stones, LPG hose and regulator assembly, angle brackets, and metal lintel.
Freestanding unit: Burner assembly, stainless steel weather cover, granite cover and trims, ceramic stones, LPG
hose and regulator assembly.
2. Select optional accessories
image unavailable
Glass bi-fold door assembly
R2612
LPG to NG conversion kit
R2613
Console base module
R2632
Console spacer module
R2633
Console door module
R2631
Metal lintel kit
R2629
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 55
Rinnai gas fireplaces
Appendices
Appendix 1: Rinnai heating running costs
Running costs can play an important part in the purchase decision. Based on the
information in the table below, calculate for yourself the approximate running cost of a
Rinnai appliance, and approximate hours a 45 kg LPG bottle will last.
Rinnai appliance
ENERGYSAVERS
Gas
Energy
consumption output
(MJ/H)
(kW/h)
45 kg bottle Running costs per hour ($)
will last
LPG
Natural Gas
(hrs)
$113.80 per 45 kg
$0.075 per kWh
LOW
HIGH
Low
HIGH
LOW
HIGH
LOW
HIGH
LOW
HIGH
Energysaver 309FT
5.80
13.00
1.20
3.10
391
174
0.29
0.66
0.12
0.27
Energysaver 561FT
9.00
21.00
1.90
4.80
252
108
0.46
1.06
0.19
0.44
Energysaver 559FT
9.00
23.00
1.90
5.30
252
99
0.46
1.16
0.19
0.48
Energysaver 1004FTR
11.00
37.00
11.00
37.00
206
61
0.56
1.87
0.23
0.78
Arriva 750 and 752
8.00
31.50
1.80
7.00
284
72
0.40
1.59
0.17
0.66
Compact 2
9.00
25.00
1.60
5.00
252
91
0.46
1.26
0.19
0.52
Evolve 950
10.00
34.00
2.4
8.13
227
68
0.51
1.72
0.21
0.71
Neo on NG
14.00
27.00
2.98
6.04
-
-
-
-
0.29
0.56
Neo on LPG
14.00
30.00
3.24
6.94
162
76
0.71
1.52
-
-
Symmetry RDV3611
19.00
33.00
3.80
7.50
119
69
0.96
1.67
0.40
0.69
Dynamo
6.00
15.00
1.70
4.20
378
151
0.30
0.76
0.13
0.31
Avenger
8.50
25.00
2.40
6.20
267
91
0.43
1.26
0.18
0.52
Indoor Super Ray 16
-
16.00
-
4.4
-
142
-
0.81
-
0.34
Indoor Super Ray 24
-
24.00
-
6.6
-
95
-
1.21
-
0.50
Indoor Super Ray 40
-
40.00
-
11.1
-
57
-
2.02
-
0.84
Outdoor Super Ray
-
24.00
-
6.6
-
95
-
1.21
-
0.50
GAS FIREPLACES
PORTABLE CONVECTORS
SUPER RAYS
Running cost scenario: Arriva models
During the cooler months the Arriva runs for approximately two hours in the morning and three hours in the evening. This equates to
approximately five hours use everyday.
t Approximate weekly cost on Natural Gas:
$5.95-$23.10 (low to high)
t Approximate weekly cost on LPG:
$14-$55.65 (low to high)
This table is meant as a guide only. Please refer to the notes regarding running cost assumptions and how values have been calculated.
Always double check figures based on your own use. Please note: All Rinnai appliances, excluding the manual Super Rays require
electricity to run―electricity costs have not been factored into the hourly running costs.
Rinnai Gas Fireplaces Specification Guide 04-14 ¦ 57
Running cost assumptions and calculations
LPG gas bottle energy calculation
1 kg of LPG gas contains 50.4 MJ of energy
1 kW = 3.6 MJ
This means that a 45 kg LPG bottle has 2268 MJ (45 kg x 50.4 MJ)
LPG and Natural Gas costs
Natural Gas costs are based on the Genesis Energy Auckland charges as at 15 January 2014
(7.50c/kWh) including GST, a 10% prompt payment discount, and excluding the fixed line charge.
LPG costs are based on the Genesis Energy Auckland standard charges ($113.80 per 45 kg bottle refill
and standard delivery), including GST, and excluding LPG annual bottle rental, and excluding electricity
running costs.
The cost of LPG and Natural Gas will differ in each area, please check with your local supplier. The cost of
cylinder rental, line charges and other variables are not included in the running costs.
Calculating your own running costs
To calculate running costs on LPG:
1. Calculate the cost of gas per MJ/h, for example; $113.80 ÷ 2268 MJ = $0.050 per MJ/h
2. Calculate the approximate running cost per hour, for example; $0.050 x 5.80 MJ/h = $0.29 per hour
To calculate running costs on Natural Gas:
1. Convert the MJ input of the appliance to kW, for example; 5.80 MJ/h = 1.61 kW/h
2. Calculate the approximate running cost per hour, for example; $0.075 x 1.61 kW/h = $0.12 per hour
58 ¦ Rinnai Gas Fireplaces Specification Guide 04-14