advertisement
▼
Scroll to page 2
of 40
SHARP CORPORATION TI NSJA103FBRZ 4KK ENGLISH Thank you very much for purchasing this SHARP dehumidifier. Please read this manual carefully to ensure safe, effective use of your dehumidifier. Please read carefully through ÒPrecautionsÓ before commencing to use this product. Please keep this manual within easy reach so that you can refer to it at any time you need. Precautions........................................ E-2 Proper Uses........................................... E-5 Part Names and Functions................... E-6 Preparations Before Using................... E-8 Operation Procedure ............................ E-9 Dehumidifying auto operation Continuous dehumidify operation Dry clothes operation Changing the air flow direction.......... E-12 How to Operate the Timer .................. E-13 Emptying the Water Tank .................. E-14 Continuous Drainage.......................... E-15 Maintenance ........................................ E-16 Things to remember............................ E-17 Defrosting ............................................E-17 Before calling for Service................... E-18 ENGLISH CONTENTS DW-R249A_eng Precautions Various symbols are used throughout this manual and on the product to alert you to points relating to safe use of this product. These symbols are classified according to the seriousness of the risk involved if they are Warning Failure to follow this instruction may Cautions Failure to follow this instruction may ignored and explained below. result in death or serious injury. result in injury or damage to property. Please read this section carefully and follow the instructions. Warning Do not place the unit near any heat Do not operate the unit at voltages sources. other than the rated voltage of 220V. Prohibited Using this product at any other voltage may Prohibited Otherwise resin material in the result in electric shock or fire. product may melt Do not joined Prohibited connect electric this cords product or and catch fire. using extension cords, or sharing a power socket with other electrical appliances. Otherwise there is a Do not modify the unit. This unit should risk of electric shock, not be disassembled or repaired by heat or fire. Prohibited persons other than a qualified technician. Otherwise fire, electric shock or injury may result. Do not modify or cause damage to the power cord in any way. Prohibited Handle the power cord with care. Avoid damaging it, bending it sharply, pulling, twisting, bundling or heating it, placing When any abnormality (e.g. a burning heavy smell) is noticed, turn the power off, objects on it or getting it caught between objects. Otherwise the power cord may be damaged, Prohibited resulting in electric shock or fire. unplug the unit and consult the SHARP Service Center. If the unit continues to be operated despite signs of abnormality, Do not try to take out the plug by pulling a breakdown, electric the power cord in order to stop operation. shock Prohibited Otherwise electric shock or fire may result. may be replaced by the manufacturer, its objects (pins, wire, sticks) into the air outlet or air intake. fire If the supply cord is damaged, it must Do not insert your finger or foreign Prohibited or result. Musts service agent or similarly qualified persons in order to avoid a hazard. A fan is rotating at high speed inside Make sure that the power plug is not the unit. Do not put covered with dust before inserting the your hands inside the unit to injury, avoid Musts plug into the power socket. Regularly wipe off the power electric shock and damage plug with a dry cloth. to the unit. Dust on the plug will prevent a proper connection, which may result in electric shock and fire. Do not place any spray cans or other hazardous materials near the unit. Prohibited Also make sure not to place any ignition If repair is required, please consult hazard materials (gasoline, thinner) near the the SHARP Service Center. unit. Otherwise these materials could ignite or explode, resulting in a fire. Musts Otherwise fire, electric shock or injury may result. E-2 DW-R249A_eng Meaning of the Symbols Actions that should be strictly avoided. Prohibited Actions that must be taken. Musts Take care to read through the safety cautions before commencing to use this product. Keep this manual within easy reach so that you can refer to it at any time. Cautions Do not move the unit on its casters on Do not use the an uneven surface. drinking water for to prevent damage to the casters or the floor. humans or pets. This also applies to moving the unit on a thick- The drained water may be piled carpet. The casters could leave marks on harmful to health. floors and carpets. Do not stand on the unit or Do not knock over the unit or drop it. Do not store or move the unit on its side. Prohibited lean against it. Prohibited Otherwise the unit could move or fall over, resulting in personal injury. This could damage the unit or result in water leakage and short circuit. Do not place a combustion device (e.g. stove) near the Do not operate the unit in a closet or in a narrow, Prohibited ENGLISH drained water as Prohibited Prohibited confined space between air outlet of the dehumidifier. Otherwise incomplete combustion may result. Precautions Prohibited Lift the unit up to move it on an uneven surface furniture. Insufficient ventilation can result Take care to hold the plug firmly when in overheating or combustion. unplugging the unit. Prohibited Pulling the cord may cause the wire inside to break, resulting in overheating. Do not place any vessels containing Prohibited Do not obstruct the air outlet or air intake water, e.g. a vase, with clothing or any other materials. on the unit. Water spilled Prohibited Otherwise the air flow will be obstructed, resulting on the in overheating, ignition or unit malfunction. may impair electrical insulation, resulting in electric When the unit is not in shock, short circuits or fire. use, the WIDE SWING protects it from entry of Do not install this unit in locations where dust and dirt. there is any risk of exposure to leaking oil Prohibited or combustible gas. Leaking oil or gas near the the unit may cause fire. Do not use the unit in an elevated location, like on top of a table. Prohibited This product is for indoor use only. Do Prohibited Otherwise the unit could fall down, resulting in not install in locations exposed to direct personal injury or damage to the unit. sunlight or without shelter. Otherwise this may lead to overheating, electric Do not install the unit in shock, short circuits or fire. locations exposed to Do not use this unit for storage of any items that require strict Prohibited Prohibited splashing water. Otherwise electric shock, short circuits or fire may result. temperature control, such as art works or academic materials. Otherwise the quality of these items may actually deteriorate. Do not wash the unit directly with water. Prohibited Otherwise electric shock may result. E-3 DW-R249A_eng ・・・Precautions Precautions Cautions Musts When water is to be drained When moving the unit, drain water first from continuously, take care that the tank. Move its caster the hose is not bent and that Musts by grasping the carrying the hose outlet is positioned handle firmly so that the below the unit. dehumidifier may not be Otherwise drained water may spill inclined. and make household appliances or Do not bend Otherwise this can cause furniture wet. the drain hose. injuries or damage to the floor. If a drain hose is used, take care that the Musts temperature around the hose does not fall Make below 0¡C. only on level, stable surfaces. Otherwise, water in the hose may freeze causing undrained water to leak from the unit and make Musts sure to operate this product An uneven surface may cause stored water to spill Musts and to make household furniture or appliances wet, household furniture or appliances wet. or to cause electric shock, short circuits or fire. Before moving the unit make sure that If the unit is continuously being used for a long the power is turned off and that the period of time, make sure to inspect it regularly. tank is emptied. Otherwise spilled water may wet household appliances Musts Otherwise overheating or electrical short circuits may result. resulting in electric shock, short circuits or fire. When operating the unit for a prolonged Leave a clearance around the unit of at period in the same location, check for least the size shown in the drawing below. Musts Insufficient ventilation can result in overheating Musts or combustion. Keep 50cm min. dirt under and around the unit. Move the unit occasionally and clean the floor under it. Keep 20cm min. Whenever the unit is to be Musts left unused for a long period, make sure to unplug the unit for safety. Keep 20cm min. Otherwise, electric shock or fire may result. Cautions for use Do not operate this product with the power cord still wound onto the cord clamps. Otherwise, overheating or fire may result. When [ ] lights on the LED display on the operation panel and operation stops, the unit may be used under one of the following conditions and in one of the following locations. This is normal and does not indicate a problem with the unit. Is the unit operating at a room temperature of more than 35¡C, with the unit's WIDE SWING louver blowing toward the rear in DRY CLOTHES mode at "Low" air flow rate or in CONTINUOUS DEHUMIDIFY mode at "Low" air flow rate? Is the air outlet or air intake covered with a cloth or the like? Check whether the unit is operated in a location with inadequate ventilation such as a closet or a narrow space between furniture. Check whether the unit is operated in an improper place under direct sunshine, near heating sources or air outlet of hot wind emerging from air conditioners or oil fan heaters. Check that the size of the room where you are operating the unit is not too small. When the compressor for the cooling cycle becomes abnormally hot, operation is automatically stopped for safety. If this happens, unplug the power cord from the wall outlet, eliminate the problem, and restart operation after a waiting period of about 40 minutes. If the [ ] indicator still remains on, consult the shop where you purchased the unit or your nearest SHARP Service Center. Operating the unit in DRY CLOTHES or CONTINUOUS DEHUMIDIFY mode for long periods causes the room temperature to rise and the air to dry out. Do not operate the unit for long periods in rooms where people are present. Keep the unit at least 2 m away from a TV, radio or wave clock. Otherwise the unit may cause radio interference. E-4 Keep at least 2 m away Lighting To ensure good operating efficiency, avoid repeatedly opening doors and windows in the room where the unit is operating. Proper Uses Lowering room humidity To maintain room humidity at a comfortable level. Automatically maintain the room humidity in the range 55% to 60%. Preventing mold formation. For the rooms on the north side or store rooms where people are normally not present. AUTO DEHUMIDITY AUTO E-9 MOLD ATTACK AUTO PREVENT Prevent condensation on ceilings, walls and windows. CONDENSATION E-10 page CONTINUOUS DEHUMIDIFY Drying washing E-11page DRY CLOTHES When you want to quickly dry clothes. Dry washing Seen from the front of the unit, the air flow exits slightly to the right. When drying clothes, use the WIDE SWING louver to make sure the air flow is directed toward the laundry and dries it quickly. In winter when the room temperature is low (below 10¡C), use the dehumidifier in combination with a room heater to reduce the drying time. While you are away Set timer before you leave. Come home and experience the pleasant surroundings. Living room or kitchen Dehumidify while you rest. Stand-type rack for dring clothes Dry bedding It is efficient to dry the bedding etc. PLASMACLUSTER ION effect Plasmacluster ions surround the mold spores floating in the room air and inactivate*1them. This reduces the odor generated when mold propagates. ・ Measuring method: In PLASMACLUSTER ION operation, the density of mold spores floating in the air is measured by an air sampler. Testing organization: Ishikawa Prefecture Preventive Medicine Organization Disinfection method: Discharge of plasmacluster ions into the air. Plasmacluster ions deactivate floating mold spores Plasmacluster ions (a large quantity of plus and minus ions) attach themselves to the surface of floating mold spores. Mold spores The plasmacluster ions, composed of plus ions (hydroger ions: H+) and minus ions (oxygen ions: O2-), react at the surface of floating mold spores and change to highly active hydroxyl radical OH. Mold spores The hydroxyl radical OH extracts the hydrogen atom (H) from the cell walls of the floating mold spores, thus destroying the cell walls. Mold spores ENGLISH For drying carpet. For drying the insides of cupboards and closets. (Open the closet door to dry out the closet) Precautions / Proper Uses / PLASMACLUSTER ION effect To reduce the humidity of rooms where no one is present. Effective uses page Mold spores with destroyed cell walls self-destroy. *1 They lose their ability to propagate. E-5 DW-R249A_eng Part Names and Functions Front view Water tank E-14・E-16 page PLASMACLUSTER ION indicator FULL TANK Indicator Tank lid Tank handle Float Blinks (green) when the tank is full. Rear view Air Outlet WIDE SWING Louver Filter Handle E-12 page E-16 page Air intake Continuous drainage hole Cord clamp Band E-15 page E-4・E-16 Power supply cord Plug E-16 page Hanging power supply cord together. Caster Drain water from the tank. 1 Use to move the unit. page 3 Incline the unit. 4 Move Over-inclination might cause Incline the unit at an angle of 30¡ to 40¡ degrees 2 floor and water to leak. by putting Lift the carrying handle. Caution your foot on the Do not place back of the unit. power supply cord between the caster. Do not take out the water tank immediately after operation has stopped to prevent water leakage. Move the unit by lifting it up when the floor is easily damaged or at a rugged place. Do not use the caster on a thick-piled carpet. This can cause damage to the surface of the carpet. E-6 damage to the DW-R249A_eng The numbers inside page refer to the page where a detailed explanation of the item is given. (For explanatory purposes, all of the LED indicators are shown.) Control panel TIMER OFF indicator DRY CLOTHES air flow indicator TIMER ON indicator CONTINUOUS DEHUMIDIFY LED Display air flow indicator (HUMIDITY/TIMER SETTING indicator) TIMER SETTING indicator AUTO indicator AUTO DEHUMIDIFY PREVENT CONDENSATION indicator HUMIDITY indicator MOLD ATTACK indicator UP/REAR/WIDE Air Flow indicator PLASMACLUSTER ION indicator TIMER SETTING button POWER ON/OFF button Sets ON/OFF TIMER. Turns the dehumidifier on/off. E-13∼E-14 page WIDE SWING button E-9∼E-11 page AUTO DEHUMIDIFY button E-12 page E-9 page Changes the air flow direction. Changes over between AUTO (DEHUMIDIFY) / PREVENT CONDENSION / MOLD ATTACK. E-8 page PLASMACLUSTER ION button Turns PLASMACLUSTER ION operation on/off. DRY CLOTHES button Starts drying clothes. Specifications Model Rated voltage Rated dehumidification capacity Rated power consumption * Stand by mode Dehumidification area Water tank capacity Length of power supply cord Outside dimensions Weight Accessories Elbow joint (1) DW-R268A 220V 50Hz L / Day 26.0 W 360 1.0W and less than W m2 (Wooden houses33∼∼67 concrete houses) L Approx.6.7 (Automatic stop at 6.0) m Available length approx. 1.8 mm 380(W)×294(D)×597(H) kg 16.0 Used for hose connection for continuous water drainage. E-10 page Press to select CONTINUOUS DEHUMIDIFY operation and the desired air flow rate. E-11page Frequency Supplied CONTINUOUS DEHUMIDIFY button Printed matter Power consumption corresponds to 80% of the humidity value. The dehumidification area is based on Japanese Electrical ManufacturersÕ Association (JEMA) Standards. * The term Òstand-byÓ means that the dehumidifier is kept at ÒOFFÓ position even though its plug has been inserted into the power socket. Part Names and Functions (Specifications / Supplied Accessories) ENGLISH OPERATION indicator (1 unit) Operation manual E-7 DW-R249A_eng There may occasionally be water in the water tank when the unit is operated for the first time. This is the drain water generated when the product was inspected at the factory and does not indicate a problem with the unit. Preparations Before Using Before operating Do not remove the blue part inside the float. Insert the plug into the power socket. If the ÒFull Tank indicatorÓ blinks, empty the water tank and reinstall the tank properly. 入 湿度 切 時間後 While in operation, the unit operates in PLASMACLUSTER ION PLASMACLUSTER button Lighting 上 後 ワイド ド 弱 強 フルパワー 自動 結露防止 operation in all modes. * PLASMACLUSTER ION operation alone is not possible. タイマー スイング 連続除湿 To stop PLASMACLUSTER ION operation, press the PLASMACLUSTER ION button. The PLASMACLUSTER (Clean) indicator will go off. To resume operation, press the PLASMACLUSTER ION button again. HUMIDITY indicator Blinking Caution (The humidity in the indication example is 68%.) When ON of the POWER ON/OFF button is pressed, the humidity is indicated. After plugging the power plug into the wall outlet and pressing ON of the POWER ON/OFF button, the humidity sensor activates for about 1 minute. During this period, the HUMIDITY indicator wil blink. Blinking The displayed humidity is a guideline value, and may differ from the actual room humidity. Pip Lighting Displayed when the room humidity exceeds 81%. Lighting Displayed when the room humidity is below 39%. TEMPERATURE indicator Normally the room temperature is not displayed, but when it rises above 41¡C or drops below 0¡C, the display blinks as shown at right, indicating that the allowable operating temperature range has been exceeded. Room temperature more than 41¡C Room temperature less than 0¡C Blinking 「 」 「 」 Blinking AUTO OFF function In the event that the user forgets to turn off the unit, the AUTO OFF function automatically turns it off 12 hours after it has been turned on, regardless of the operating mode. Caution When the OFF TIMER has been set, it has priority over the AUTO OFF TIMER. The moment the OFF TIMER is released, the AUTO OFF TIMER is set automatically. When operation starts, the 12-hour AUTO OFF TIMER is set automatically. The AUTO OFF TIMER operates even when the TANK FULL indicator lights during operation and the unit stops. After 12 hours, the TANK FULL indicator will go off and all operations stop. Notifications after operation stop 12 hours after the unit has been turned on, the following notifications are issued and all operations stop. A beep sounds for 1 second. Blinking The OFF TIMER indicator blinks. [ ] appears on the LED display. To release operation stop Press the POWER ON/OFF button. A beep sounds, and the unit enters normal operation standby mode. Digital display : 「 」Lighting AUTO OFF TIMER indicator : blinking Releasing AUTO OFF function to dehumidify for a long period To dehumidify with continuous drainage, refer to E-15 page . To resume operation, press the POWER ON/OFF button twice. After pressing once, the AUTO OFF indicator goes off, and after pressing again, operation starts. E-8 自動除湿 DW-R249A_eng Operation Procedure AUTO DEHUMIDIFY operation (Indication example) AUTO DEHUMIDIFY mode, slightly high humidity, WIDE SWING louver in air flow direction "Up". WIDE SWING button AUTO DEHUMIDIFY button POWER ON/OFF button Lighting Lighting Lighting Lighting 2 Pip 1 Press the POWER ON/OFF button. Pip WIDE SWING louver The OPERATION indicator lights and AUTO DEHUMIDIFY operation starts. With the start of operation, the WIDE SWING louver rotates from "Close" to "Up" and stops in that position. PresstheAUTODEHUMIDIFYbuttonandselectoperationmode. Operation mode is switched in order. AUTO The unit stops dehumidifying and blows air only when the humidity is about less than 60% at temperatures up to 27¡C, and when the humidity is about less than 55% at temperatures of 28¡C or higher. (Right figure) Humidity % 2 CLOSE 65 55 27 40 Humidity % will stop and the unit will change to fan operation. (See figure at right.) The room temperature is 35¡C or more and humidity is less than 40%. The room temperature is above 28¡C and less than 35¡C, and humidity is less than 30%. MOLD ATTACK 29 DEHUMIDIFY operating range controlling the volume of air flow: ÒMediumÓ at temperature of about 15¡C or more and ÒHIGHÓ at about 15¡C or less. Caution 28 Temperature ¡C DEHUMIDIFY operation is continuously carried out by Under the following conditions, PREVENT CONDENSATION operation DEHUMIDIFY AUTO operating range 60 However, depending on the room size and construction, the unit may not stop dehumidifying. PREVENT CONDENSATION UP To prevent the formation of mold, use the unit in rooms where mold tends to form such as rooms on the north side or store rooms where people are normally not present. 35 30 25 28 30 35 Temperature ¡C Preparations Before Using / Operation Procedure 1 3 Pip ENGLISH OPERATION indicator When humidity drops to below 50%, the dehumidifying operation stops and the unit changes to fan operation. 3 Set the direction of the WIDE SWING louver. Choose the optimum setting. Stop E-12 page Press the POWER ON/OFF button again. When operation stops, the WIDE SWING louver returns to "Close" position. Note that in stopped condition, the humidity is not indicated. * If the POWER ON/OFF button is pressed to restart the unit after a stop, the unit resumes operation in the previous selected mode. E-9 DW-R249A_eng CONTINUOUS DEHUMIDIFY operation (Indication example) CONTINUOUS DEHUMIDIFY mode, air flow rate "Low", slightly high humidity, WIDE SWING louver in air flow direction "Up". WIDE SWING button Lighting CONTINUOUS DEHUMIDIFY button POWER ON/OFF button Lighting Lighting Lighting OPERATION indicator Pip Pip 3 1 2 1 Pip Press the POWER ON/OFF button. The OPERATION indicator lights and AUTO DEHUMIDIFY operation starts. With the start of operation, the WIDE SWING louver rotates from "Close" to "Up" and stops in that position. 2 Press the CONTINUOUS DEHUMIDIFY button. The "Low" air flow indicator for CONTINUOUS DEHUMIDIFY lights, and the unit starts CONTINUOUS DEHUMIDIFY operation at "Low" air flow. Caution In the cases below, the unit stops dehumidifying and blows air only. E-9 page When the room humidity is below 40% at temperatures over 35¡C When the room humidity is less than 30% at temperatures more than 28¡C but less than 35¡C This causes the room temperature to rise and the air to dry out. Do not operate the unit for long periods in rooms where people are present. Changing the air flow rate Press the CONTINUOUS DEHUMIDIFY button again and select Air Flow mode. The CONTINUOUS DEHUMIDIFY Air Flow indicator lights and the air flow rate changes in the sequence shown below. * 3 Stop * At Full Power, the unit operates at a dehumidifying rate equal to 26 liters/day. Set the direction of the WIDE SWING louver. Choose the optimum setting. E-12page Press the POWER ON/OFF button again. When operation stops, the WIDE SWING louver returns to "Close" position. Note that in stopped condition, the humidity is not indicated. * If the POWER ON/OFF button is pressed to restart the unit after a stop, the unit resumes operation in the previous selected mode. E-10 DW-R249A_eng ・・・ Operation Procedure DRY CLOTHES operation (Indication example) DRY CLOTHES mode, slightly high humidity, WIDE SWING louver in air flow direction "Up" WIDE SWING button Lighting Lighting DRY CLOTHES button POWER ON/OFF button Lighting Lighting OPERATION indicator 1 2 1 Pip Press the POWER ON/OFF button. The OPERATION indicator lights and AUTO DEHUMIDIFY operation starts. With the start of operation, the WIDE SWING louver rotates from "Close" to "Up" and stops in that position. 2 Press the DRY CLOTHES button. The "Low" indicator for DRY CLOTHES mode lights, and the unit starts DRY CLOTHES operation at "Low" air flow. Caution In the cases below, the unit stops dehumidifying and blows air only. E-9 page When the room humidity is below 40% at temperatures over 35¡C When the room humidity is less than 30% at temperatures more than 28¡C but less than 35¡C Changing the air flow rate Press the DRY CLOTHES button again and select Air Flow mode. The DRY CLOTHES Air Flow indicator lights and the air flow rate Operation Procedure 3 ENGLISH Pip Pip changes in the sequence shown below. Combining this with PLASMA CLUSTER ION (Clean) mode will deactivate the mold spores floating in the air (see 3 E-5 page for CLUSTER ION effect) and help to make your clothes even cleaner. Set the direction of the WIDE SWING louver. Choose the optimum setting. Stop E-12 page Press the POWER ON/OFF button again. When operation stops, the WIDE SWING louver returns to "Close" position. Note that in stopped condition, the humidity is not indicated. * If the POWER ON/OFF button is pressed to restart the unit after a stop, the unit resumes operation in the previous selected mode. Caution At "High" air flow rate, your clothes will dry faster, but the unit will generate more noise. E-11 DW-R249A_eng Changing the air flow direction The WIDE SWING button allows you to select "Up", "Rear" or "Wide" for the air flow direction, or stopping (Off) it at a desired angle. Press the WIDE SWING button during operation. By repeatedly pressing the WIDE SWING button, the position of the WIDE SWING louver can be changed in the sequence shown below. To stop the WIDE SWING louver at a desired angle, press the button again (Off) when the louver has reached the desired angle. (OFF) (Indication example) AUTO DEHUMIDIFY WIDE SWING louver Operation in Wide Air Flow position 弱 強 弱 強 フルパワー 自動 結露防止 カビアタック Lighting 衣類乾燥 Pip 連続除湿 UP 自動除湿 REAR 運 転 入/切 WIDE WIDE SWING button Caution When operation stops, the WIDE SWING louver returns to "Close" position. To restart operation, press the WIDE SWING button again and select the air flow direction. Do not expose the WIDE SWING louver to impact or rotate it by force. Otherwise the louver may be damaged. After a change in air flow direction, the WIDE SWING louver is determining its position, so it may take a few seconds until it starts moving. Any object touching the WIDE SWING louver may cause the air flow direction to change. In this case, set the air flow direction again with the WIDE SWING button. The sound produced by the air flow changes with the air flow direction. E-12 DW-R249A_eng How to Operate the Timer To set on timer It can be set only when the unit is shut down. Confirm that the OPERATION indicator has gone out and operation has stopped. 1 Press the TIMER button. The ON TIMER indicator, [ TIMER ON TIMER SETTING indicator indicator ] on the LED display and the Lighting TIMER SETTING indicator light. At the same time, the indicator for the previously selected mode lights. ( power plug has been plugged in, or when the POWER ON / OFF button is pressed after a power outage, the unit is preset to start operation in AUTO DEHUMIDIFY mode. ス イング Lighting When the TIMER button is kept pressed, the indication on the 1 LED display changes automatically. While pressing the TIMER button, the timer setting time changes as shown below in 1-hour increments. Select the setting time. p Pi TIMER SETTING button No indication ENGLISH ( When the POWER ON/OFF button is pressed after the 上 後 ワイド 2 Select the desired operating mode. Select the desired operating mode by pressing the AUTO DEHUMIDIFY button, CONTINUOUS DEHUMIDIFY button or DRY CLOTHES button. The following settings can be changed as desired. When AUTO DEHUMIDIFY is selected, the DEHUMIDIFY mode can be changed by pressing the AUTO DEHUMIDIFY button. E-9 page When CONTINUOUS DEHUMIDIFY or DRY CLOTHES is selected, the air flow mode can be selected with the respective selector button. E-10∼E-11 page Pressing the WIDE SWING button lets you select the air flow direction from the WIDE SWING louver. Pressing the PLASMACLUSTER button turns PLASMACLUSTER ION operation on and off. Example E-12 page E-8 page If you set ON TIMER operation as Òafter 5 hoursÓ The timer indication changes every hour from 5→4→3→2→1, and after 5 hours operation starts. Caution When the TANK FULL indicator blinks, empty the drain tank. The operating mode can be changed even after ON TIMER operation has been selected. To change the mode, press the respective operation button. Canceling ON TIMER operation Changing the air flow direction / How to Operate the Timer (set release) To release timer operation, either press the TIMER button until the ON TIMER and TIMER SETTING indicators go off or press the POWER ON/OFF button. E-13 DW-R249A_eng ・・・ How to Operate the Timer To set off timer it can be set when the unit is in operation Confirm that the OPERATION indicator is on and the unit is in operation. 1 TIMER OFF indicator Press TIMER SETTING button Blinking Indications change simultaneously as follows: the OFF TIMER indicator lights, the LED display changes to [ ], the HUMIDITY indicator goes off, and the TIMER 上 SETTING indicator lights. The OFF TIMER setting time is indicated as [Off after 1 hour]. ワイド Indicating set-time of OFF TIMER as ÒOFF after 1 hourÓ. Select set-time of TIMER since the TIMER shifts sequentially in order as follows. (one-hour interval) Lighting Lighting Room humidity (set release) The indication automatically shifts by continuously pressing TIMER SETTING button. Example If you set OFF TIMER operation as Òafter 5 hoursÓ The timer indication changes every hour from 5→4 1 →3→2→1, TIMER SETTING button and after 5 hours operation stops. Caution Pip When the OFF TIMER works (operation stops), a beep sounds for about 1 second. You can change the time to stop operation after having set the OFF TIMER. Press the TIMER button again. To cancel Off Timer To release the OFF TIMER, either press the TIMER button until the LED display indicates the room humidity, say [ ], or press the POWER ON/OFF button to stop operation. When taking out the water tank, the front full Emptying the Water Tank tank green lamp will blink up and the unit stops its operation. If the water tank fills to a level of approx. 6.0 liters, the operation stops automatically. Then an electronic beep sound will be emitted for 8 seconds, and the ÒfullÓ indicator light will blink showing that the water tank is full. Empty the tank as shown below. 1 Water tank Remove the water tank. Pull here to Pull out the tank by pushing up the tank handgrip a little and take the tank out remove tank carefully by holding it with both hands. The tank weighs about 7.0 kg when it is filled up to the limit. Be careful to avoid getting injured when taking it out. 2 Empty the water tank. Float Tank handle Tank lid The drainage tank can be carried by holding the tank handle. Empty the water tank, clean the tank and wipe off excess water outside the tank. If water remains on the float, the automatic stop function of the dehumidifier will not work properly. So make sure to wipe away the water from the float. Inside of the float a blue part is installed. Do not take off the part, it is necessary for function of operating the dehumidifier. 3 Reinstall the water tank in the unit. (1) Make certain that the tank lid is installed securely on the exterior of the tank, and that the handle is stowed in its stowage position. (2) Push the tank into the unit until it comes into firm contact with the back of the unit. Caution E-14 Do not touch anything inside the unit after Before moving the unit, make sure to turn it off and the water tank is removed. drain the water from the tank. Otherwise when the tank is full, the automatic stop function may not work properly. Otherwise water may spill out onto the floor. Clean the inside of the water tank periodically At low temperatures, water may freeze in the unitÕs (about once a week). cooling system instead of collecting in the water tank. The unit may be soiled if it is not cleaned for a long time. Note that this is not a sign of failure. DW-R249A_eng Continuous Drainage Cautions when using the unit with continuous drainage This dehumidifier is for home use. If you use it with continuous drainage, make sure to check the unit at least once every 2 weeks for a dirty filter or clogged drain hose. If you are using a drain hose, make sure that the temperature around the hose does not drop below 0¡C. Water in the hose might freeze causing water to spill and wet the floor and the unit. Cover the end of the hose with netting to prevent insects from entering. The AUTO OFF function also works during CONTINUOUS DRAINAGE. 12 hours after the start of operation, the unit will automatically stop. The AUTO OFF function can be canceled as described below. Canceling the AUTO OFF function Before using CONTINUOUS DRAINAGE As explained in "Preparations before use" ( E-8 page ) the AUTO OFF function will shut down the unit automatically after 12 hours of normal operation. If you do not wish this function to work during continuous drainage, you can cancel it as described below. WIDE SWING button POWER ON/OFF button Plug in the power plug. While pressing the WIDE SWING button in stopped condition, keep When setting is completed, there will be a beep sound, the LED display indicates [ ENGLISH the POWER ON/OFF button pressed for at least 3 seconds. Press together ] and the FULL TANK indicator for at least lights for 5 seconds. 3 seconds To reactivate the AUTO OFF function, disconnect the power plug from the wall outlet and carry out the procedure described in above. After 3 seconds, the beep sounds CONTINUOUS DRAINAGE is possible, if there is a place to drain water nearby. Make sure to stop operation, disconnect the power plug from the wall outlet and carry out the following procedure. 1 Open a drain hose hole. Rear view Remove the water tank. Using a screwdriver, punch a hole at the drain hose hole located at the back of the unit. Smoothen the edge of the hole with a file etc. 2 Drain hose hole Attach the elbow joint to the other end of the hose inserted into the continuous drainage hole. Remove the drainage tank. Pull down the drain stopper located at the upper right inside the casing. Put your finger behind the rubber packing on the drain stopper. Then pull the rubber packing off toward the front and remove the drain seat at the same time. * These are important parts you will need when not using CONTINUOUS DRAINAGE. Keep the rubber packing and drain seat in a safe place. Attach the elbow joint to the other end of the hose inserted into the continuous drainage hole. Commercial hose, 15mm internal diameter. Drain hose hole Drainage outlet Elbow joint Rubber packing Insert more than 10mm Drain stopper Front view into hose. Elbow joint Drain seat * Before inserting the hose into the continuous drainage hole, remove the rubber packing and drain seat. 3 4 Insert the elbow joint into the drainage outlet of the unit. How to Operate the Timer / Continuous Drainage to indicate that setting is completed. Insert the elbow joint into the drainage outlet of the unit all the way to the joint base. Re-install the water tank. Elbow joint The unit does not operate without the water tank in place. (The unit is turned off with water-brimmed direction device in the unit.) Positioning of the The hose must Do not bend drainage hose for be below the the hose. continuous dehumidification level of the drainage hole. To stop continuous drainage and return the dehumidifier to its original state At least 10cm The end of the hose should not come in direct contact with water. Pull the joint elbow toward you and pull it out of the continuous drainage hole together with the hose. Align the rubber packing with the hole in the drain seat, then insert these two parts firmly into the hole of the drain stopper. E-15 DW-R249A_eng Maintenance Water tank 1 For safety purposes, turn off and unplug the unit before carrying out any maintenance. For clean, sanitary and pro-long use, regular maintenance is recommended. (About once a week) Removing and installing the tank lid, tank handle, and tank float. (1) Detach the tank lid gradually from the left or right toward the opposite side. Lever (2) Drop the tank handle to the front position as shown in the illustration on the right, and slightly spread out the left and right side arms of the handle so that the shafts come out, and remove the handle from the water tank. (3) Push the float in the direction shown in the diagram and remove it from the hole. With the float in this state, pull it out in direction (4) To reinstall, follow the above procedure in reverse ( Water . tank ). Float If you do not insert the tank float securely, the tank can overflow, and the unit will not stop. Take due care. 2 3 Wash the inside of the water tank. After prolonged use, the drain water may cause the tank to go black. If this happens, wash the tank with a sponge, warm water and a mild detergent. Wipe the water tank with a soft cloth, and install the tank lid, tank handle, and tank float. * After having reinstalled these parts, make sure to move the float lever up and down with your finger to confirm that it moves smoothly. If the float sticks, the overflow protection device located behind the lever will not work and the tank may overflow. Filter * This filter is not intended for air (About once 2 weeks) purification. Filter A clogged filter will result in reduced dehumidification efficiency and higher power consumption. It can also cause odor. If you operate the unit without the filter, dust will accumulate in the unit, which may result in malfunction. Remove dust and dirt with the corner tool of your vacuum cleaner. Cleaning the filter If the filter is very dirty, wash it with neutral detergent diluted in warm water. Rinse it off and let it dry well in the shade. Main body Dirty side up (About once a month) Wipe off any dirt from the unit using a piece of soft cloth soaked in warm water (40¡C max.) or with detergent. If detergent is used, make sure to wipe off the detergent with a damp cloth. The air intake and outlet become dirty easily, so make sure to clean them well. If water is allowed to splash on the unit, electrical insulation may be affected and corrosion of the unit may eventually result. Caution Use a neutral detergent (e.g. for dish washing) for cleaning. Do not use the following types of cleaning agents as they will damage plastic parts. Thinners, benzine, alcohol, petrol, powder soap, powder polish, alkaline washing agents, hot water, acid or scrubbing brushes. Do not scrub or expose the unit to chemically treated cloths for any prolonged period of time as this may damage the surface of the unit. If the unit is not used for a long time 1 Empty the water tank completely. Remove the tank lid, tank handle and tank float, and wipe off any excess water in the tank. Power supply cord See above 2 Clean the filter. 3 Wind the power supply cord around the clamp on the rear panel. Storage Band See above Dry the unit thoroughly and cover with a sheet for dust protection. Store the unit in a well ventilated place that is not exposed to direct sunlight. If the unit is left uncovered without any protection, dust will accumulate so that the air emitted by the unit will be dusty next time the dehumidifier is used. E-16 DW-R249A_eng Things to remember The temperature at which the unit can be operated is 5¡C to 35¡C. If the room temperature is over 35¡C, the built-in protection system will automatically turn off the unit. Dehumidifying operation increases room temperature. (The dehumidifier does not have a cooling function.) The unit generates heat during operation and will become warm. It will blow out warm air, but this is normal and does not indicate a problem with the unit. Dehumidification capacity will increase as temperature rises (as shown in the chart on the right). In winter when the room temperature is low (below 10¡C), use the dehumidifier in combination with a room heater to reduce the drying time. In case of 80% 20 in humidity. In case of CONTINUOUS 15 Full power mode. DEHUMIDIFY operation at 10 0 0 15 20 25 30 Room temperature (¡C) Wait for 3 minutes before restarting the unit If the unit is turned off, wait for at least 3 minutes before restarting operation. If the unit is restarted immediately, the compressor will wait for 3 minutes to start up as part of the unitÕs self-protection system. Canceling the beeps indicating FULL TANK and OFF TIMER end WIDE SWING button PLASMACLUSTER button (Operation stopped by AUTO OFF function) Follow the steps below to disable the tank full alarm: Plug the power plug into the socket. When the PLASMACLUSTER and WIDE SWING buttons are pressed simultaneously during operation stop for at least 3 seconds, the setting beep sounds. Press the POWER ON/OFF button and remove the drain tank. If the beep does not sound, the setting is completed. To return to the previous condition, either carry out the procedure described in again or disconnect the power plug from the wall outlet and plug it in again to cancel the setting. Press together for 3 seconds ENGLISH humidity. 25 Maintenance / Things to remember / Defrosting based on room temperature and Dehumidifying capacity (L/day) Dehumidification capacity will vary Defrosting If the room temperature is below 16¡C, frost may form on the cooling device of the dehumidifier, and the automatic defrosting function will automatically switch on. During defrosting, air flow is stopped and the sound of operation will change. The length of time that defrosting will operate will vary according to room temperature and humidity, but will be carried out about 5 minutes at 45 minute intervals. (The duration of a defrost cycle will be longer when the temperature is lower.) E-17 DW-R249A_eng Before Calling for Service Symptoms ? Check Points Is the water tank installed properly? Unit does not operate Is the water tank full? when power ON/OFF Is the unit plugged in properly? button is pressed. Is the LED display displaying [ Has there been a power failure? ]? If it is, disconnect the power plug and contact the shop where you purchased the unit. Dehumidification Is the filter clogged? capacity has dropped. Is the temperature and humidity of your room too low? Is the air outlet or intake obstructed? Humidity does not reduce Is the room too large? in any of the operating mode. Are there any appliances which make steam such as an oilstove? Are there much opening and closing of a window or an entrance? Displayed humidity is changed suddenly by opening and closing of a window or Displayed humidity is an entrance, changing the wind direction when operation is beginning. It is normal. different from actual Displayed humidity indicates the ambient humidity around the unit. humidity. This may be different to the humidity in a different location in the same room. This sound is generated during CLUSTER ION operation. Intermittent If the sound bothers you at bedtime, move the unit further away. operating sound. louder or less loud, or at times no sound may be heard at all. There is no Depending on the humidity in the room, the operating noise may become relationship with the CLUSTER ION effect. Is the dehumidifier properly installed on a stable base? Is the floor flat? Operation is noisy. When the unit starts its operation at a low temperature, the sound might increase for several seconds. (The time depends on the temperature condition.) Has the unit been knocked over, or has it been tilted or dropped? Water is leaking. Is the pipe connection or hose connection for continuous drainage in place? The unit repeats operating Is the humidity being automatically controlled using AUTO DEHUMIDIFY, and stopping. (See pages E-9~E-11.) [ MOLD ATTACK, CONTINUOUS DEHUMIDIFY, or DRY CLOTHES mode? If [ ] lights on the LED display and operation stops. Error Codes LED Display ] continues to appear after checking the problem based on page E-4, "Cautions for Use", disconnect the power plug and contact the shop where you purchased the product or your nearest SHARP Service Center. Description Remedy Defrosting exceeded 30 minutes Defrosting thermistor defective Room temperature sensor defective Power clock abnormal Gas leak detected Compressor locked E-18 Disconnect the power plug and contact the shop where you purchased the product. SHARP CORPORATION TI NSJA103FBRZ 4KK DW-R249A_HK SHARP CORPORATION TINSJA103FBRZ 4KK
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project