DC UPS Adapter
Quick Guide V. 1.0
1. Package Contents
You should have received the following items inside of package:
- DC UPS adapter unit
- Quick Guide
If anything is missing or damage in the package, please contact your dealer.
2. Product Overview
3. Installation and Operation
NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged.
Connect to Utility and Charging
Plug in the AC input plug ( ) to the wall outlet. The UPS will be automatically turned on and green LED will light on. If battery is not fully charged, the UPS will auto charge battery and green LED will flash.
Connect the Loads
Plug in the loads to DC output connector ( ) of the UPS. Then, connected device will be protected by UPS unit.
Restart/Off Button
LED indicator
DC output connector
AC input
LED Indication
This LED is two-color indicator: green or red color depending on operation status.
Status
Power on with battery fully charged.
Power on with charging battery.
UPS is on but power failure occurs. UPS will transfer to DC mode and battery is discharging.
Color
Green
Green
Green
On/Flash
On
Steady Flash
Quick Flash
Any fault occurs on UPS. Red On
4. Applications
The DC UPS is designed to provide emergency power backup to all kinds of DC-powered equipment such as routers, modems, set-top box, VOIP phone systems, surveillance system, alarm system, access control system and many critical telecom equipment.
5. Important Safety Warning (SAVE THESE INSTRUCTIONS)
To safely operate this DC UPS, please read and follow all instructions carefully.
Read this manual thoroughly before attempting to unpack, install, or operate.
You may keep this quick guide for further reference.
CAUTION! Do NOT place this unit under the hot and humid environment.
CAUTION! Do NOT disassemble this product.
CAUTION! If the battery level is low, please recharge battery immediately.
CAUTION! When install or replace a new battery, be sure positive (+) and negative (-) are correctly connected. Otherwise, DC UPS will be damaged.
5. Trouble Shooting
Use the table below to solve minor problems.
Problem
Red LED is on.
Possible Cause Solutions
Overload or short circuit occurs Press button for more than 1 second on UPS and UPS transfers to and release to restart unit. fault mode.
Battery backup time is shorter than nominal Battery is far too low. value.
No output and LED indicator is not on.
Internal fault has occurred.
Contact your dealer to replace the special battery.
Contact your dealer.
6. Specifications
AC INPUT
Voltage Range
Frequency
DC OUTPUT
Voltage
Max. Power
BATTERY
Type
Nominal Voltage
Capacity
Typical Charging time
PHYSICAL
90 VAC ~ 264 VAC
50 or 60 Hz
12VDC ± 5%
25W (2.1A)
Lithium-ion Battery
3.7VDC
2600mAh
3 hours recover to 90% capacity
Input Plug
Output cable
Dimension, D X W X H (mm)
Mounted on the housing (NEMA/Schuko/UK)
1m Length (DC Male Jack, OD 4mm, ID 1.7mm)
68 x 42 x 74
280g Net Weight
7. Approximate Back-up Time Table
Load Backup Time @ 12Vdc (min)
12V/1.0A Router
12V/1.5A Router
12V/2.0A Router
150
120
90