Cabletron Systems SmartSwitch 8H02-16 User`s guide

Add to my manuals
132 Pages

advertisement

Cabletron Systems SmartSwitch 8H02-16 User`s guide | Manualzz

8H02-16 SmartSwitch 10/100

USER’S GUIDE

SmartSwitch 10/100

S ECURE

F AST VIRTUAL NETWORKING

8H02-16

RESET

COM

PWR

CPU

1X

2X 3X

4X

5X 6X

7X 8X

9X 10X

11X

12X

13X

14X

15

MMAC

Smart

SWITCH

16

1742-00

Only qualified personnel should install the 8H02-16.

NOTICE

Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron

Systems to determine whether any such changes have been made.

The hardware, firmware, or software described in this manual is subject to change without notice.

IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL,

INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT

NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR

THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN

ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH

DAMAGES.

Copyright 1996 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005

All Rights Reserved

Printed in the United States of America

Order Number: 9031742-02 August 1996

SPECTRUM , LANVIEW , and MMAC are registered trademarks and Element Manager ,

FE-100FX , FE-100TX , S ECURE F AST , and SmartSwitch are trademarks of Cabletron Systems, Inc.

All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.

Printed on

8H02-16 User’s Guide

Recycled Paper i

Notice

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

DOC NOTICE

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of

Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique

édicté par le ministère des Communications du Canada.

VCCI NOTICE

This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas.

Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.

Read the instructions for correct handling.

ii 8H02-16 User’s Guide

Notice

CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT

IMPORTANT: Before utilizing this product, carefully read this License Agreement.

This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the

“Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME

BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND

THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT

AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED

PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.

CABLETRON SOFTWARE PROGRAM LICENSE

1.

LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.

You may not copy, reproduce or transmit any part of the Program except as permitted by the

Copyright Act of the United States or as authorized in writing by Cabletron.

2.

OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the

Program.

3.

APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.

EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY

1.

EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media).

CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO

YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING

BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND

FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE

ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.

2.

NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL

CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER

(INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,

PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL,

INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS)

ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT,

EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH

DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR

LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR

ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES, IN SOME

INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO

YOU.

8H02-16 User’s Guide iii

Notice

UNITED STATES GOVERNMENT RESTRICTED RIGHTS

The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the

Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.

For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the

DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at

252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.

iv 8H02-16 User’s Guide

CONTENTS

CHAPTER 1 INTRODUCTION

1.1

Using This Guide ......................................................................... 1-1

1.2

Structure of This Guide................................................................ 1-2

1.3

8H02-16 Overview....................................................................... 1-3

1.4

Local Management Features....................................................... 1-6

1.5

Optional Features ........................................................................ 1-6

1.6

Document Conventions ............................................................... 1-7

1.7

Getting Help................................................................................. 1-8

1.8

Related Manuals.......................................................................... 1-9

CHAPTER 2 NETWORK REQUIREMENTS

2.1

Network Requirements ................................................................ 2-1

2.2

100BASE-TX Network Cable Lengths......................................... 2-4

CHAPTER 3 INSTALLATION

3.1

Required Tools ............................................................................ 3-1

3.2

Unpacking the 8H02-16............................................................... 3-1

3.3

8H02-16 Options ......................................................................... 3-2

3.4

Installing the 8H02-16.................................................................. 3-2

3.5

Connecting to the Network .......................................................... 3-6

CHAPTER 4 TROUBLESHOOTING

4.1

Using LANVIEW .......................................................................... 4-1

4.2

FE-100TX LED ............................................................................ 4-3

4.3

Troubleshooting Checklist ........................................................... 4-5

4.4

Using the RESET Button ............................................................. 4-6

CHAPTER 5 COM PORT AND TELNET CONNECTIONS

5.1

Local Management Terminal Connection.................................... 5-1

5.2

Configuring the Terminal ............................................................. 5-1

5.3

Connecting a Management Terminal to the 8H02-16.................. 5-3

5.4

Connecting the UPS to the 8H02-16 ........................................... 5-3

5.5

Runtime IP Address Discovery.................................................... 5-4

5.6

COM Port and Telnet Connections.............................................. 5-4

8H02-16 User’s Guide v

Contents

CHAPTER 6 LOCAL MANAGEMENT

6.1

Overview ......................................................................................6-1

6.2

Local Management Keyboard Conventions .................................6-2

6.3

Accessing Local Management .....................................................6-3

6.4

Device Menu Screen....................................................................6-6

6.5

Device Configuration Menu Screen .............................................6-8

6.6

General Configuration Screen ...................................................6-10

6.7

SNMP Community Names Screen.............................................6-23

6.8

SNMP Traps Screen ..................................................................6-26

6.9

Configuring the Trap Table ........................................................6-27

6.10 Bridge Configuration Screen ......................................................6-28

6.11 Device Specific Configuration Menu Screen..............................6-31

6.12 Full Duplex Configuration Screen ..............................................6-33

6.13 System Resources Screen ........................................................6-36

6.14 High Speed Interface Configuration Screen ..............................6-39

6.15 Flash Download Screen .............................................................6-44

6.16 Clear NVRAM Screen ................................................................6-48

6.17 Port Redirect Function Screen ...................................................6-50

6.18 Device Statistics Menu Screen ..................................................6-53

6.19 Bridge Statistics Screen .............................................................6-54

6.20 Port Statistics Screen.................................................................6-55

6.21 Network Tools ............................................................................6-58

APPENDIX A SPECIFICATIONS

A.1

Device Specifications .................................................................. A-1

A.2

Physical Properties ..................................................................... A-1

A.3

Electrical Specifications .............................................................. A-1

A.4

Environmental Requirements...................................................... A-1

A.5

Input/Output Ports ....................................................................... A-2

A.6

COM Port/Pin Assignments ........................................................ A-2

A.7

Agency Approvals ....................................................................... A-3

APPENDIX B FE-100TX AND FE-100FX SPECIFICATIONS

B.1

FE-100TX.................................................................................... B-1

B.2

FE-100FX.................................................................................... B-2

vi 8H02-16 User’s Guide

Contents

APPENDIX C OPTIONAL INSTALLATIONS AND

MODE SWITCH BANK SETTINGS

C.1

Required Tools ............................................................................C-1

C.2

Removing the Chassis Cover ......................................................C-2

C.3

Setting the Mode Switch..............................................................C-4

C.4

Installing Optional Fast Ethernet Interface Modules....................C-6

INDEX

8H02-16 User’s Guide vii

Contents viii 8H02-16 User’s Guide

CHAPTER 1

INTRODUCTION

Welcome to the Cabletron Systems 8H02-16 SmartSwitch 10/100

User’s Guide .

This guide describes the 8H02-16 SmartSwitch and provides information concerning network requirements, installation, troubleshooting, and the use of Local Management for device local control and management.

1.1

USING THIS GUIDE

Read through this guide completely to understand the 8H02-16

SmartSwitch features, capabilities, and Local Management functions. A general working knowledge of Ethernet and IEEE 802.3 type data communications networks and their physical layer components is helpful when using Local Management.

NOTE

In this document, the 8H02-16 SmartSwitch is referred to as either the “8H02-16” or the “device.”

8H02-16 User’s Guide 1-1

Chapter 1: Introduction

1.2

STRUCTURE OF THIS GUIDE

This guide is organized as follows:

Chapter 1,

Introduction

, outlines the contents of this manual and briefly describes the 8H02-16 features. Directions about how to receive additional help and a list of related manuals are also included.

Chapter 2,

Network Requirements , explains the network requirements

to consider before installing the 8H02-16.

Chapter 3,

Installation , provides instructions on how to install the unit

and connect segments to the device.

Chapter 4,

Troubleshooting , details the 8H02-16 LANVIEW LEDs that

enable you to quickly diagnose network/operational problems.

Chapter 5,

COM Port and Telnet Connections , describes how to attach

a management console to the 8H02-16 to access Local Management (LM) or attach an uninterruptible power supply (UPS).

Chapter 6,

Local Management

, describes how to access Local

Management and use the Local Management screens to manage the

8H02-16.

Appendix A,

Specifications , contains information on functionality and

operating specifications, connector pinouts, environmental requirements, and physical properties.

Appendix B,

FE-100TX and FE-100FX Specifications , contains

information about FE-100TX pinouts and information concerning cable types used with the FE-100FX.

Appendix C,

Optional Installations and Mode Switch Bank Settings ,

describes how to remove the top cover to gain access to and set the Mode

Switch Bank, and install optional Fast Ethernet Interface Modules.

1-2 8H02-16 User’s Guide

8H02-16 Overview

1.3

8H02-16 OVERVIEW

The 8H02-16 is a standalone 16-port high-speed network switch device that supports traditional switching (bridging). Ports 15 and 16 support optional Fast Ethernet Interface Modules and can provide uplinks to

100BASE-TX or 100BASE-FX fast Ethernet networks.

The 8H02-16 is used to connect individual high-bandwidth user devices, such as workstations, and provide a central switching point for multiple

Ethernet segments built using devices such as Cabletron Systems

HUBSTACK or other third party stackable devices.

The 8H02-16 is a tabletop unit that can also be installed in a standard

19-inch rack using the supplied rack mounting hardware.

The 8H02-16 has a universal ac power supply with automatic voltage sensing that allows operation using 100–125 or 200–250 Vac, 50/60 Hz.

1.3.1

8H02-16 Features

The 8H02-16, shown in Figure 1-1, has the features listed below.

SmartSwitch 10/100

WITH

S

ECURE

F

AST VIRTUAL NETWORKING

8H02-16

MMAC

Smart

SWITCH

RESET

COM

PWR

CPU

1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X 13X 14X 15 16

Port Status LEDs

System LEDs

COM Port

RESET Button

Network Ports 1-14

Fast Ethernet Interface

Module Ports 15 & 16

Figure 1-1 The 8H02-16

• Intel i960 RISC processor control

• 14 Port High-Speed Workgroup Switch with two optional ports for

Fast Ethernet Interface Modules providing high speed uplinks to

100 Mbps fast Ethernet technologies

8H02-16 User’s Guide 1-3

Chapter 1: Introduction

• Full Duplex Switched Ethernet (FDSE) support for 20 Mbps links to bandwidth intensive users/servers

• Runtime IP Address Discovery that allows the 8H02-16 to send out a

RARP or BootP request to determine its IP address

• Manageable using Simple Network Management Protocol (SNMP) and Remote Monitoring (RMON)

• Support for traditional switching services as well as for Cabletron

Systems S ECURE F AST Switching Virtual Network technology

• Possible linking of existing stackable or third party hubs to 100 Mbps

Fast Ethernet backbones

• IEEE 802.3 compatibility with support for IEEE 802.1d and DEC

Spanning Tree Algorithms

• LANVIEW Diagnostic LEDs

1.3.2

Connectivity

The 8H02-16 connects to Ethernet networks or workstations through fourteen RJ45 ports on the front panel. These ports support Unshielded

Twisted Pair (UTP) and Shielded Twisted Pair (STP) cables at lengths up to 100 meters. The ports are IEEE 802.3 10BASE-T compliant.

The 8H02-16 has two front panel slots (ports 15 and 16) for optional Fast

Ethernet Interface Modules to support an uplink to 100 Mbps Ethernet backbones or a high speed connection to a local server.

1.3.3

Full Duplex Switched Ethernet

Each switched Ethernet port supports full wire-speed Ethernet communications and can be configured to operate in Full Duplex

Switched Ethernet mode.

1-4 8H02-16 User’s Guide

8H02-16 Overview

1.3.4

Management

Management of the 8H02-16 is accomplished using Local Management tools or remote SNMP management stations. Out-of-band local management is provided through the RS232 COM port on the front panel using a VT100 terminal or a VT100 terminal emulator. In-band remote management is possible through any SNMP compliant Network

Management Software.

1.3.5

Traditional Switching

The 8H02-16 provides traditional Switching or S

ECURE

F

AST

Switching

Virtual Network Services between all of the front panel interfaces including the optional ports 15 and 16.

Through Cabletron Systems Synthesis framework, the 8H02-16 supports operations in traditional Switching mode or S ECURE F AST Switching mode. S

ECURE

F

AST

Switching allows for future migration to Virtual

Network technologies without requiring the replacement of existing equipment.

1.3.6

Standards Compatibility

The 8H02-16 provides IEEE 802.1d Spanning Tree Algorithm (STA) support to enhance the overall reliability of the network and protect against “loop” conditions. The 8H02-16 supports a wide variety of industry standard MIBs including RFC 1213 (MIB II), RFC 1271

(RMON), RFC 1371 (RS232 MIB), RFC 1493 (Bridge MIB) and RFC

1354 (FIB MIB). A full suite of Cabletron Systems Enterprise MIBs provide a wide array of statistical information to enhance troubleshooting.

1.3.7

LANVIEW Diagnostic LEDs

LANVIEW diagnostic LEDs serve as an important troubleshooting aid by providing an easy way to observe the status of individual ports and overall

network operations. Chapter 4 provides details about the 8H02-16

LANVIEW LEDs.

8H02-16 User’s Guide 1-5

Chapter 1: Introduction

1.4

LOCAL MANAGEMENT FEATURES

Local Management provides the tools that allow management of the

8H02-16 and any of the optional Fast Ethernet Interface Modules installed as ports 15 and 16. It also allows the following tasks to be performed:

• Assign an IP address and subnet mask to the 8H02-16.

• Select a default gateway and default interface.

• Control local and remote access.

• Designate workstations to receive SNMP traps from the 8H02-16.

• Configure module specific SNMP MIB objects including the IETF

Bridge MIB objects and many of the RMON MIB objects.

Chapter 6 provides detailed information about Local Management.

1.5

OPTIONAL FEATURES

The two optional Memory Upgrade Kits for the 8H02-16 SmartSwitch are listed below:

• The 8H02-16-MEM-UGK Memory Upgrade Kit provides an 8 MB

DRAM SIMM that allows the 8H02-16 to run SFS (Secure Fast

Switching) and all groups of RMON.

• The 8H02-8D/4F-ADV Advanced Memory Upgrade Kit provides

8 MB DRAM, 4 MB of FLASH with a preloaded image, and image diskettes that allows the 8H02-16 to run VLAN (Virtual Local Area

Network), SFS, and RMON.

1-6 8H02-16 User’s Guide

Document Conventions

• Cabletron Systems provides Fast Ethernet Interface Modules to support uplinks to 100 Mbps Ethernet backbones or high speed connections to local servers. The Fast Ethernet Interface Modules are listed in Table 1-1.

Table 1-1 Fast Ethernet Interface Modules

P/N Description Application

FE-100TX

FE-100FX

Uses RJ45 connector

Uses SC connector

Supports Unshielded Twisted Pair (UTP) cabling.

Supports multimode fiber optic cabling.

1.6

DOCUMENT CONVENTIONS

The following conventions are used throughout this document:

NOTE

Note symbol. Calls the reader’s attention to any item of information that may be of special importance.

TIP

Tip symbol. Conveys helpful hints concerning procedures or actions.

!

CAUTION

Caution symbol. Contains information essential to avoid damage to the equipment.

Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard.

WARNING

Warning symbol. Warns against an action that could result in personal injury or death.

8H02-16 User’s Guide 1-7

Chapter 1: Introduction

1.7

GETTING HELP

If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact

Cabletron Systems Technical Support:

Phone

CompuServe

Internet mail

FTP

Login

Password

(603) 332-9400

Monday – Friday; 8 A .

M . – 8 P .

M . Eastern Time

GO CTRON from any ! prompt [email protected]

ctron.com (134.141.197.25) anonymous your email address

BBS (603) 335-3358

Modem setting 8N1: 8 data bits, 1 stop bit, No parity

For additional information about Cabletron Systems products, visit our

World Wide Web site: http://www.cabletron.com/

Before calling Cabletron Systems Technical Support, have the following information ready:

• A description of the failure

• A description of any action(s) already taken to resolve the problem

(e.g., changing mode switches, rebooting the unit, etc.)

• A description of your network environment (layout, cable type, etc.)

• Network load and frame size at the time of trouble (if known)

• The serial and revision numbers of all Cabletron Systems products in the network

• The device history (i.e., have you returned the device before, is this a recurring problem, etc.)

• Any previous Return Material Authorization (RMA) numbers

1-8 8H02-16 User’s Guide

Related Manuals

1.8

RELATED MANUALS

The following manuals may help the user to control and manage the

8H02-16 using SNMP network management systems:

Cabletron Systems SPECTRUM Element Manager for Windows

Cabletron Systems SPECTRUM and SPECTRUM Portable Management

Applications (SPMA) products

Third Party SNMP compliant Network Management Packages

8H02-16 User’s Guide 1-9

Chapter 1: Introduction

1-10 8H02-16 User’s Guide

CHAPTER 2

NETWORK REQUIREMENTS

This chapter contains general networking guidelines. Before attempting to use the 8H02-16 or to install a Fast Ethernet Interface Module

(FE-100TX or FE-100FX), review the requirements and specifications outlined in this chapter.

2.1

NETWORK REQUIREMENTS

The network installation must meet the guidelines included in this chapter to ensure satisfactory performance of this equipment. Failure to follow these guidelines may produce poor network performance.

Refer to the following sections that apply to your specific network configuration.

2.1.1

10BASE-T Twisted Pair Network

When connecting a 10BASE-T twisted pair segment to any of the

8H02-16 ports (Interfaces 1 through 14), ensure the network meets the following requirements:

Length

The IEEE 802.3 standard for 10BASE-T requires that 10BASE-T devices transmit over a 100 meter (328 foot) link using 22–24 AWG Unshielded

Twisted Pair (UTP) wire. However, cable quality largely determines maximum link length. If you use high quality, low attenuation cable, you can achieve link lengths of up to 200 meters. Cable delay limits the maximum link length to 200 meters.

NOTE

Losses introduced by connections at punch-down blocks and other equipment reduce total segment length. For each connector or patch panel in the link, subtract 12 meters from the total length of the cable.

8H02-16 User’s Guide 2-1

Chapter 2: Network Requirements

Impedance

Cabletron Systems 10BASE-T twisted pair products work on twisted pair cable with 75 to 165 ohms impedance. UTP cables typically have an impedance from 85 to 110 ohms. Shielded twisted pair cables, such as

IBM Type 1 cable with an impedance of 150 ohms may also be used.

Temperature

Multi-pair PVC 24 AWG telephone cables typically have an attenuation of approximately 8–10 dB/100 m at 20

°

C (68

°

F). The attenuation of PVC insulated cable varies significantly with temperature. At temperatures greater than 40

°

C (104

°

F), use plenum-rated cable to ensure that attenuation remains within specification.

2.1.2

100BASE-TX Twisted Pair Network

The 8H02-16 with an FE-100TX installed in ports 15 or 16 provides an

RJ45 connection that supports UTP cabling. The device at the other end of the twisted pair segment must meet IEEE 802.3u 100BASE-TX specifications for the devices to operate at 100 Mbps. Use Category 5

UTP cabling for networks operating at 100 Mbps. Use Category 3, 4, or 5

UTP cabling for networks operating at 10 Mbps.

NOTE

The 8H02-16 with an FE-100TX installed is capable of operating at either 10 or 100 Mbps. The FE-100TX senses the speed of the other device and adjusts its speed accordingly.

When connecting a 100BASE-TX twisted pair segment to port 15 or 16 with an FE-100TX interface module, the network must meet the following requirements:

Length

The IEEE 802.3u standard for 100BASE-TX requires that 100BASE-TX devices be capable of transmitting over a 100 meter (328 foot) link using

Category 5 UTP cable.

The IEEE 802.3 standard for 10BASE-T requires that 10BASE-T devices be capable of transmitting over a 100 meter (328 foot) link using

Category 3, 4, or 5 UTP cable.

2-2 8H02-16 User’s Guide

Network Requirements

Propagation Delay

Propagation delay is the amount of time it takes data to travel from the sending device to the receiving device.

Total propagation delay allowed for a 100BASE-TX (100 Mbps) network is 256 bit times or 2.56 microseconds (2.56

µ s). If the total propagation delay between any two nodes on a 100BASE-TX network exceeds

2.56

µ s, then use bridges or other devices to further segment the network.

Total propagation delay allowed for a 10BASE-T (10 Mbps) network is

256 bit times or 25.6

µ s. If the total propagation delay between any two nodes on a 10BASE-T network exceeds 25.6

µ s, then use bridges or other devices to further segment the network.

Temperature

The attenuation of PVC insulated cable varies significantly with temperature. At temperatures greater than 40

°

C (104

°

F), use plenum rated cables to ensure that cable attenuation remains within specification.

2.1.3

100BASE-FX Fiber Optic Network

Ports 15 and 16 of the 8H02-16 support the Cabletron Systems FE-100FX fiber optic interface module. The FE-100FX meets the IEEE 802.3u standard. When connecting a fiber optic segment to the 8H02-16, the network must meet the following requirements:

Cable Loss

Test the fiber optic cable with a fiber optic attenuation test set adjusted for an 850 nm wavelength. This test verifies that the signal loss is within an acceptable level. The maximum loss for a multimode cable is 11.0 dB.

Fiber Optic Budget and Propagation Delay

Determine the maximum fiber optic cable length by calculating the fiber optic budget delay and total network propagation before fiber optic cable runs are incorporated in any network design.

Fiber optic budget is the combination of the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors.

8H02-16 User’s Guide 2-3

Chapter 2: Network Requirements

Propagation delay (collision delay) is the amount of time it takes data to travel from the sending device to the receiving device. Total propagation delay allowed for the entire network is 256 bit times (2.56

µ s). If the total propagation delay between any two nodes on the network exceeds

2.56

µ s, then use bridges or other devices to further segment the network.

2.2

100BASE-TX NETWORK CABLE LENGTHS

This section details the maximum network cable lengths specified by the

IEEE 802.3u standard. As stated in the previous sections, the physical size of the network is limited primarily by propagation delay. The total propagation delay cannot exceed 256 bit times or 2.56

µ s.

A 100BASE-TX/FX network might use all copper (UTP) links, all fiber links or a combination of both. The maximum length of any segment is determined by the types and combination of links and by the type of repeater (if any) between segments. IEEE 802.3u standards specify two repeater classes (Class 1 and Class 2) and the maximum cable lengths for each media type.

If this device is being installed in a 100BASE-TX/FX environment with repeaters, use the repeater instruction manual to determine the maximum cable lengths when laying out your network.

UTP Maximum Cable Lengths

An Unshielded Twisted Pair copper segment in a 100BASE-TX environment may be no more than 100 meters in length.

!

C AUT IO N

The maximum length of a UTP segment may be no more than

100 meters.

Multimode Fiber Cable Lengths

The maximum length of a 100BASE-FX segment may be no more than

412 meters between Data Terminal Equipment (DTE to DTE) in half duplex mode or 2 km (DTE to DTE) in full duplex mode.

2-4 8H02-16 User’s Guide

CHAPTER 3

INSTALLATION

Only qualified personnel should install the 8H02-16.

This chapter covers the following items:

• Required tools

• Unpacking the 8H02-16

• Installing the 8H02-16 on a shelf or into a standard rack

• Connecting to the power source

• Connecting to the network

3.1

REQUIRED TOOLS

A Phillips screwdriver is required to install the equipment.

3.2

UNPACKING THE 8H02-16

To unpack the shipment, proceed as follows:

1. Carefully remove the 8H02-16 from the shipping box. Save all shipping material in case any items need to be returned.

2. Visually inspect the 8H02-16 and any optional equipment.

3. If there are any signs of damage, contact Cabletron Systems Technical

Support. Refer to Section 1.7, Getting Help, for details.

8H02-16 User’s Guide 3-1

Chapter 3: Installation

3.3

8H02-16 OPTIONS

Install the options first before proceeding to Section 3.4.

NOTE

If the 8H02-16 is to be installed with optional Fast Ethernet Interface

Modules, refer to Appendix C for installation instructions. For more

information on the two Fast Ethernet Interface Modules and the two

optional memory kits, refer to Section 1.5, Optional Features.

3.4

INSTALLING THE 8H02-16

The 8H02-16 may be installed on a tabletop, shelf, or in a 19-inch rack.

Refer to Section 3.4.1 for information concerning a tabletop or shelf

installation. Section 3.4.2 describes the rackmount installation.

3.4.1

Tabletop or Shelf Installation

This section provides guidelines for installation on a tabletop or shelf.

A

B

C

SmartSwitch 10/100

WITH

S

ECURE

F

AST VIRTUAL NETWORKING

8H02-16

MMAC

Smart

SWITCH

RESET

COM

PWR

CPU

1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X 13X 14X 15 16

A = 15 cm (6 in)

B = 46 cm (18 in)

C = 53 cm (21 in)

D = 213 cm (7 ft)

D

Figure 3-1 Tabletop or Shelf Installation

Proceed to Section 3.4.3 for instructions about connecting power.

1742_06

3-2 8H02-16 User’s Guide

Installing the 8H02-16

3.4.2

Rackmount Installation

To install the 8H02-16 in a 19-inch rack, Cabletron Systems includes an accessory kit containing the rackmount brackets, mounting screws, and a strain-relief bracket for cable management.

WARNING

Before installing the 8H02-16 into a rack, ensure that the rack supports the device(s) without compromising the stability of the rack. Otherwise, personal injury and/or equipment damage may result.

Tabletop and shelf installations must be within reach of the network cabling and meet the requirements listed below:

• Locate the 8H02-16 within seven feet of an appropriate grounded power receptacle that meets the power supply requirements listed in

Appendix A, Specifications.

• Maintain a temperature of between 5

°

C (41

°

F) and 40

°

C (104

°

F) at the installation site with fluctuations of less than 10

°

C per hour.

!

CAUTION

To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1 cm (2.0 in) at the left, right and rear of the 8H02-16.

8H02-16 User’s Guide 3-3

Chapter 3: Installation

Attaching the Strain-Relief Bracket

Attach the strain-relief bracket to the front of the 8H02-16 as follows:

1. Locate the strain-relief bracket and four 8-32 x 3/8-inch pan-head screws in the rackmount kit.

Do not attempt to attach the strain-relief bracket with screws other than the 8-32 x 3/8-inch screws included with the

8H02-16. Use of longer screws may damage the unit or cause electrical shock.

2. Attach the strain-relief bracket to the bottom of the 8H02-16 using the

four 8-32 x 3/8-inch pan-head screws (Figure 3-2).

Screws (4)

Strain-Relief Bracket

Smart

MMAC

SWITCH

1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X 13X 14X 15 16 8H02-16 COM

RESET

CPU

PWR

TUAL NETWORKING AST VIR

F

ECURE

S

WITH

SmartSwitch 10/100

174247

Figure 3-2 Attaching the Strain-Relief Bracket

3-4 8H02-16 User’s Guide

Installing the 8H02-16

Rack Mounting the 8H02-16

Proceed as follows to install the 8H02-16 into a 19-inch rack.

1. Remove and discard the four cover screws (two from each side) located along the front edges of each side of the 8H02-16.

2. Locate the four 6-32 x 3/8-inch flat head cover replacement screws in the rackmount kit. Use these screws to attach the rackmount brackets

to the 8H02-16 as shown in Figure 3-3.

Rackmount

Brackets (2)

SmartSwitch 10/100

WITH

S

ECURE

F

AST VIRTUAL NETWORKING

8H02-16

MMAC

Smart

SWITCH

RESET

COM

PWR

CPU

1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X 13X 14X 15 16

Screws (4)

Figure 3-3 Installing the Rackmount Brackets

1742-04

3. With the mounting brackets installed, position the 8H02-16 between the vertical frame members of the 19-inch rack and fasten it securely

with mounting screws as shown in Figure 3-4.

19-Inch Rack

SmartSwitch 10/100

WITH

S

ECURE

F

AST VIRTUAL NETWORKING

8H02-16

MMAC

Smart

SWITCH

RESET

COM

PWR

CPU

1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X 13X 14X 15 16

Screws (4)

Figure 3-4 Installing the 8H02-16 in a Rack

1742-03

8H02-16 User’s Guide 3-5

Chapter 3: Installation

3.4.3

Connecting to the Power Source

NOTE

The 8H02-16 has a power supply with automatic voltage sensing that allows connection to power sources ranging from

100–125 Vac or 200–250 Vac, 50/60 Hz.

To connect the 8H02-16 to a power source, proceed as follows:

1. Plug the power cord into a grounded wall outlet. The POWER LED turns ON (green) and the CPU LED turns ON (green) briefly.

It takes approximately one minute for the 8H02-16 to boot up.

NOTE

2. Observe the LANVIEW LEDs. After boot up, the CPU LED becomes solid green. If the CPU LED is not solid green, check the power cord connection and power source. If the CPU LED is still not solid green after approximately one minute, contact Cabletron Systems Technical

Support. Refer to Section 1.7, Getting Help, for details.

3.5

CONNECTING TO THE NETWORK

This section provides the procedures for connecting UTP and multimode fiber optic segments from the network or other devices to the 8H02-16.

Ports 1 through 14 on the 8H02-16 have RJ45 connectors for UTP connections. Ports 15 and 16 support FE-100TX or FE-100FX Fast

Ethernet Interface Modules. The FE-100TX has an RJ45 connector for a

UTP cable connection. The FE-100FX has an SC style connector for a multimode fiber optic cable connection.

Refer to Section 3.5.1 to make UTP connections to ports 1 through 14.

Refer to Section 3.5.2 to make a UTP connection to an FE-100TX.

Refer to Section 3.5.3 to make a fiber optic connection to an FE-100FX.

3-6 8H02-16 User’s Guide

Connecting to the Network

3.5.1

Connecting UTP Cables to Ports 1 Through 14

Before connecting a segment to the 8H02-16, check each end of the segment to verify wire crossover.

!

CAUTION

To establish a link, you must have an odd number of crossovers (preferably one) between 10BASE-T devices of the same type (i.e., from repeater to repeater or transceiver to transceiver).

.

Connect a twisted pair segment to the 8H02-16 as follows:

1. Ensure that the device at the other end of the segment is connected to the segment and is powered ON.

2. Refer to Figure 3-5. Connect the twisted pair segment to the 8H02-16

by inserting the RJ45 connector on the twisted pair segment into the desired RJ45 port (ports 1 through 14).

SmartSwitch 10/100

WITH

S

ECURE

AST

VIRTUAL NETWORKING

8H02-16

RESET COM

PWR

CPU

1X 2X

3X

4X

5X 6X

7X

8X

9X 10X

11X

12X

13X

14X

15

MMAC

Smart

SWITCH

16

Figure 3-5 8H02-16 Twisted Pair Connection

3. Verify that a Link exists by checking that the port RX LED is on

(flashing green or yellow or on solid green). If the RX LED is off, perform the following steps until it is on: a.

Check that the 10BASE-T device at the other end of the twisted pair segment is ON and connected to the segment.

b. Verify that the RJ45 connectors on the twisted pair segment have

the proper pinouts (Figure 3-6) and check the cable for continuity.

8H02-16 User’s Guide 3-7

Chapter 3: Installation

NOTE:

RX+/RX– and TX+/TX– must share a common color pair.

TO

SmartSwitch RJ45 Port

RX+ 1

RX– 2

TX+

TX–

3

6

RJ45 to RJ45

TO

10BASE-T Device Port

RX+ 1

2 RX–

3

6

TX+

TX–

1574-30

Figure 3-6 Cable Pinouts - (RJ45) Crossover Cable c.

Check that the twisted pair connection meets the dB loss and cable

specifications outlined in Chapter 2.

If a link is not established, contact Cabletron Systems Technical

Support. Refer to Section 1.7, Getting Help, for details.

4. Repeat step 2, above, until all connections have been made.

3.5.2

Connecting a UTP Segment to the FE-100TX

An FE-100-TX installed in port slot 15 and/or 16 is often used to provide a connection between the 8H02-16 and a bridge, router, or switch.

Usually, in this configuration, a “straight-through” cable is used and the

Fast Ethernet Interface Module crossover switch shown in Figure 3-7 is

set to “not crossed over.”

Normally, when connecting devices to like devices, crossing over of the transmit and receive pairs must occur. Before connecting a segment to the

FE-100TX, check each end of the segment to determine if the wires have been crossed over for the proper connection.

A schematic of a crossover cable is shown in Figure 3-6. If the wires do

not cross over, use the switch on the FE-100TX to internally cross over

the RJ45 port. Figure 3-7 shows how to properly set the FE-100TX

crossover switch.

3-8 8H02-16 User’s Guide

Connecting to the Network

Position =

(not crossed over)

Position X

(crossed over)

1. TX+

2. TX-

3. RX+

4. NC

5. NC

6. RX-

7. NC

8. NC

= x

FE-100TX

10

100

1. RX+

2. RX-

3. TX+

4. NC

5. NC

6. TX-

7. NC

8. NC

166505

Figure 3-7 FE-100TX Crossover Switch

Connect an FE-100TX to a twisted pair segment as follows:

1. Ensure that the device at the other end of the segment is connected to the segment and is powered ON.

2. Connect the twisted pair segment to the module by inserting the RJ45 connector on the twisted pair segment into the RJ45 port on the

module. See Figure 3-7.

8H02-16 User’s Guide 3-9

Chapter 3: Installation

3. Verify that a Link exists by checking that the port RX LED is on

(flashing green or yellow or on solid green). If the RX LED is off, perform the following steps until it is on: a.

Check that the 100BASE-TX device at the other end of the twisted pair segment is powered up.

b. Verify that the RJ45 connector on the twisted pair segment has the proper pinouts.

c.

Check the cable for continuity.

d. Make sure that the twisted pair connection meets dB loss and cable

specifications outlined in Section 2.1.2.

e.

Confirm that the crossover switch is in the correct position.

If a Link is not established, contact Cabletron Systems Technical Support.

Refer to Section 1.7, Getting Help, for details.

3.5.3

Connecting a Multimode Segment to the

FE-100FX

The FE-100FX has an SC style network port (see Figure 3-8). Cabletron

Systems supplies fiber optic cable that uses SC style connectors that are keyed to ensure proper crossing over of the transmit and receive fibers.

!

CAUTION

An odd number of crossovers (preferably one) must be maintained between devices so that the transmit port of one device is connected to the receive port of the other device and vice versa.

If the fiber optic cable being used has SC style connectors that do not resemble MIC style connectors, or has SC connectors on one end and a different type on the other, such as ST connectors, ensure that the proper crossing over occurs.

3-10 8H02-16 User’s Guide

Connecting to the Network

Fiber Optic Network Connection

1. Remove the protective plastic covers from the fiber optic ports on the applicable port on the module and from the ends of the connectors.

!

CAUTION

Do not touch the ends of the fiber optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants.

Contamination of the ends causes problems in data transmissions. If the ends become contaminated, clean them with alcohol using a soft, clean, lint free cloth.

2. Insert one end of the SC connector into the FE-100FX installed in the

8H02-16. See Figure 3-8.

3. At the other end of the fiber optic cable, attach the SC connector to the other device.

15

RX LED

FE-100

FX

16

174234

Figure 3-8 FE-100FX Port

8H02-16 User’s Guide 3-11

Chapter 3: Installation

4. Verify that a Link exists by checking that the port RX LED is flashing green or yellow, or on solid green. If the RX LED is off, perform the following steps until it is on:

The port RX LED flashes green and yellow during bootup.

NOTE a.

Check that the power is turned on for the device at the other end of the Link.

b. Verify proper crossing over of fiber strands between the applicable port on the 8H02-16 and the fiber optic device at the other end of the fiber optic link segment.

c.

Verify that the fiber connection meets the dB loss specifications

outlined in Chapter 2.

If a Link has not been established, contact Cabletron Systems Technical

Support. Refer to Section 1.7, Getting Help, for details.

The 8H02-16 is now ready to be set up through Local Management. Refer

to Chapter 6, Local Management, to configure the 8H02-16.

3-12 8H02-16 User’s Guide

CHAPTER 4

TROUBLESHOOTING

This chapter provides information concerning the following:

• Using the LANVIEW diagnostic and status monitoring system

• Troubleshooting network and 8H02-16 operational problems

• Using the RESET button

4.1

USING LANVIEW

The 8H02-16 uses Cabletron Systems built-in visual diagnostic and status

monitoring system called LANVIEW. The LANVIEW LEDs (Figure 4-1)

allow quick observation of the network status to aid in diagnosing of

network problems. Refer to Table 4-1 for a description of the LEDs.

For a functional description of the LANVIEW LED on the optional Fast

Ethernet Interface Module (FE-100TX), refer to Section 4.2.

Receive (RX) Transmit (TX)

SmartSwitch 10/100

WITH

S

ECURE

F

AST VIRTUAL NETWORKING

8H02-16

MMAC

Smart

SWITCH

RESET

COM

PWR

CPU

1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X 13X 14X 15 16

PWR CPU

Figure 4-1 LANVIEW LEDs

174236

8H02-16 User’s Guide 4-1

Chapter 4: Troubleshooting

LED

PWR

CPU

TX

RX

Color

Green

Red

Off

Red

Yellow

Green

Yellow and

Green

Off

Green

Yellow

Red

Off

Green

Yellow

Table 4-1 LANVIEW LEDs

State

Functional.

5-Volt output out of regulation.

Power off.

Flashing. Hardware failure has occurred.

Solid. Reset, normal power up reset.

Crippled. Limited functionality.

Functional.

Booting. Blinks yellow and green while booting.

Port enabled, and no activity.

Recommended Action

No action.

Contact Cabletron Systems

Technical Support.

Power up device.

Contact Cabletron Systems

Technical Support.

No action.

Contact Cabletron Systems

Technical Support.

No action.

No action.

Flashing. Indicates activity. Rate indicates data rate.

Blinking. Port in standby.

Flashing. Indicates collision rate.

Solid indicates numerous collisions and indicates a problem.

Port in standby if yellow TX LED is blinking, or no Link.

Solid. Port enabled, link, no activity.

Blinking. Port disabled, link.

Flashing. Indicates receive activity.

Should flash green every 2 seconds indicating BPDUs being sent if STA is enabled and there is a valid link.

No action.

Port may be disabled due to

Spanning Tree.

No action.

Contact Cabletron Systems

Technical Support for assistance.

No error.

No error.

No error.

No error.

4-2 8H02-16 User’s Guide

FE-100TX LED

4.2

FE-100TX LED

The optional FE-100TX has one LED labeled 10/100. The 10/100 LED together with the receive LED allows the user to determine the Link status and the operating speed of the Fast Ethernet Interface Module. The

10/100TX LED and the Receive (RX) LED are shown in Figure 4-2.

Table 4-2 and Table 4-3 provide a functional description of the FE-100TX

LED.

10

100 LED

Receive (RX) LED

MMAC

Smart

SWITCH

= x

FE-100TX

15

10

100

Figure 4-2 FE-100TX LED

16

174253

NOTE

A Link exists if the Receive (RX) LED is on.

LED

10/100

Table 4-2 FE-100TX LED (With Link)

Color

Off

Green

Description

FE-100TX is operating at 10 Mbps.

FE-100TX is operating at 100 Mbps.

8H02-16 User’s Guide 4-3

Chapter 4: Troubleshooting

NOTE

No Link exists if the Receive (RX) LED is off.

LED

10/100

Table 4-3 FE-100TX LED (Without Link)

Color

Off

Green

Description

No Link or no cable attached. FE-100TX forced to 10 Mbps operation, or is manually set to “auto-negotiate” mode.

No Link or no cable attached. FE-100TX is forced to 100 Mbps operation.

4-4 8H02-16 User’s Guide

Troubleshooting Checklist

4.3

TROUBLESHOOTING CHECKLIST

If the 8H02-16 is not working properly, refer to Table 4-4 for a checklist

of possible problems, causes, and recommended actions to resolve the problem.

Table 4-4 Troubleshooting Checklist

Problem

All LEDs are OFF.

No Local

Management

Password screen.

Cannot contact the

8H02-16 from in-band management.

Port(s) goes into standby for no apparent reason.

User parameters

(IP address, Device and Module name, etc.) are lost when the 8H02-16 is powered down or the front panel

RESET button is pressed.

Possible Cause Recommended Action

Loss of Power to the

8H02-16.

Port is disabled.

No link to device.

8H02-16 detects a looped condition.

Check the proper connection of the power cable and its access to a live outlet.

Check the installation.

8H02-16 not properly installed.

Autobaud not enabled.

Terminal setup is not correct.

Improper console cable pinouts.

Improper Community

Names Table.

8H02-16 does not have an IP address.

Position of the NVRAM

RESET switch was changed before the last power down or pressing of the RESET button, causing the user-entered parameters to reset to factory default settings.

Press ENTER (RETURN)

(may take up to four times).

Refer to Chapter 5 for proper

setup procedures.

Refer to Appendix A for proper console port pinouts.

Refer to Chapter 6

for Community Names Table setup.

Refer to Chapter 6 for IP

address assignment procedure.

Enable port.

Check link to device.

Discuss these configurations with Cabletron Systems

Technical Support before implementing them into your network.

Reenter the lost parameters as necessary. Call Cabletron

Systems Technical Support if problem continues.

8H02-16 User’s Guide 4-5

Chapter 4: Troubleshooting

4.4

USING THE RESET BUTTON

The RESET button shown in Figure 4-3 resets the 8H02-16 processor

without affecting the NVRAM.

NOTE

The RESET button may be used in conjunction with mode

switch 7, described in Appendix C, to clear user-entered

parameters such as IP addresses and Community Names and to replace them with the 8H02-16 default settings.

SmartSwitch 10/100

WITH

S

ECURE

F

AST VIRTUAL NETWORKING

8H02-16

MMAC

Smart

SWITCH

RESET

COM

PWR

CPU

1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 11X 12X 13X 14X 15 16

RESET Button

174237

Figure 4-3 RESET Button

To reset the 8H06-16 processor, use a pen or pencil to press and release the RESET button. The 8H02-16 goes through a reset process for approximately 45 seconds.

4-6 8H02-16 User’s Guide

CHAPTER 5

COM PORT AND TELNET CONNECTIONS

This chapter provides information about the following items:

• Connecting and configuring a management terminal to the COM port of the 8H02-16 to access Local Management

• Connecting an Uninterruptible Power Supply (UPS) to the COM port of the 8H02-16 for UPS applications

• Establishing a Telnet connection

5.1

LOCAL MANAGEMENT TERMINAL CONNECTION

Connecting a terminal to access Local Management involves the following:

• Configuring the terminal so it can communicate with the 8H02-16

• Connecting the terminal to the COM port of the 8H02-16 with an RJ45 console cable

5.2

CONFIGURING THE TERMINAL

The following instructions outline how to configure your terminal to communicate with Local Management. Refer to your specific terminal manual for more instructions if necessary.

Use one of the following systems to access Local Management:

• A Digital Equipment Corporation VT100 terminal

• An IBM or compatible PC running a VT100 emulation program

To access the Setup Directory on a VT series terminal, press F3. Table 5-1

lists the required terminal setup for a VT series terminal.

8H02-16 User’s Guide 5-1

Chapter 5: COM Port and Telnet Connections

Table 5-1 VT Terminal Setup

Display Setup Menu

Columns ->

Controls ->

Auto Wrap ->

Scroll ->

Text Cursor ->

Cursor Style ->

General Setup Menu

Mode ->

ID number ->

Cursor Keys ->

Power Supply ->

Communications Setup Menu

Transmit ->

Receive ->

XOFF ->

Bits ->

Parity ->

Stop Bit ->

Local Echo ->

Port ->

Transmit ->

Auto Answerback ->

Keyboard Setup Menu

Keys ->

Auto Repeat ->

Keyclick ->

Margin Bell ->

Warning Bell ->

80 Columns

Interpret Controls

No Auto Wrap

Jump Scroll

Cursor

Underline Cursor Style

VT100, 7 Bit Controls

VT100ID

Normal Cursor Keys

UPSS DEC Supplemental

2400, 4800, 9600, 19200

Receive=Transmit

XOFF at 64

8 bits

No Parity

1 Stop Bit

No Local Echo

DEC-423, Data Leads Only

Limited Transmit

No Auto Answerback

Typewriter Keys any option any option

Margin Bell

Warning Bell

5-2 8H02-16 User’s Guide

Connecting a Management Terminal to the 8H02-16

5.3

CONNECTING A MANAGEMENT TERMINAL TO

THE 8H02-16

The 8H02-16 comes with a Console Cable Kit that provides a cable and

RJ45-to-DB9 adapter. The adapter allows the 8H02-16 RJ45 COM port to connect to an IBM or compatible PC running a VT series emulation software package. For detailed instructions regarding the connection of the console cable to the 8H02-16, refer to the instruction sheet provided in the Console Cable Kit.

Optional adapters are available to connect the 8H02-16 to Local

Management through a VT type terminal or a modem. Refer to the RJ45

Console Cable Kit Instruction Sheet for installation instructions and adapter specifications.

5.4

CONNECTING THE UPS TO THE 8H02-16

The following hardware is needed to connect the 8H02-16 to the UPS:

• An RJ45 console cable

• An RJ45 to DB9 adapter

To connect a cable from the UPS to the 8H02-16 COM port, perform the following steps:

1. Plug the RJ45 console cable into the 8H02-16 COM port.

2. Plug the other end of the console cable into the adapter and connect the adapter to the UPS.

With the cable connection complete and with a valid IP address entered into the 8H02-16 through Local Management (see Chapter 6) or through

Runtime IP Address Discovery (refer to Section 5.5, Runtime IP

Address Discovery), use one of the following management tools to

configure the 8H02-16 COM port for the UPS application:

• 8H02-16 Local Management through Telnet. The General

Configuration screen described in Chapter 6, Section 6.6.12, provides

the instructions to set up the COM port for the UPS application.

• Graphical user interfaces (GUIs) provided by SPECTRUM Element

Manager for Windows, SPECTRUM Portable Management

Applications (SPMAs), or SPECTRUM software packages.

8H02-16 User’s Guide 5-3

Chapter 5: COM Port and Telnet Connections

5.5

RUNTIME IP ADDRESS DISCOVERY

Upon power up, the 8H02-16, through a function called Runtime IP

Address Discovery, sends out a RARP and BootP request over the network to determine its IP address. This function allows the loading of an IP address into NVRAM on the 8H02-16 without using Local

Management. For information on setting up a workstation to act as a server to respond to a RARP or BootP request, refer to the specific workstation documentation.

5.6

COM PORT AND TELNET CONNECTIONS

Once the 8H02-16 has a valid IP address, establish a Telnet session with

Local Management from any TCP/IP based node on the network. Telnet connections to the 8H02-16 require the community name passwords

assigned at the SNMP Community Names screen. Refer to Section 6.7,

SNMP Community Names Screen, of this manual for additional

information about community names.

NOTE

Refer to the instructions included with the Telnet application for information about establishing a Telnet session.

5-4 8H02-16 User’s Guide

CHAPTER 6

LOCAL MANAGEMENT

This chapter describes how to access and use Local Management for the

8H02-16.

6.1

OVERVIEW

Local Management for the 8H02-16 consists of a series of management screens that allow the management of the 8H02-16 and its attached segments. The management screens allow the user to do the following tasks:

• Assign IP addresses and subnet masks to the 8H02-16

• Select a default gateway and subnet mask

• Control access to the 8H02-16 by establishing community names

• Clear NVRAM

• Force a FLASH Download

• Designate which Network Management Workstations receive SNMP traps from the device

There are four ways to access Local Management:

• Locally using a VT type terminal connected to the COM port of the

8H02-16.

• Remotely using a VT type terminal connected through a modem.

• In-band through a Telnet connection.

• Out-of-band through a Telnet connection to the COM port of the

8H02-16 when the port is configured for SLIP or PPP.

Chapter 5 contains details on how to connect a terminal to the 8H02-16

COM port to access Local Management.

8H02-16 User’s Guide 6-1

Chapter 6: Local Management

6.2

LOCAL MANAGEMENT KEYBOARD

CONVENTIONS

All key names appear as capital letters in this manual. Table 6-1 explains

the keyboard conventions and the key functions that are used.

Key

ENTER Key

RETURN Key

ESCAPE (ESC) Key

SPACE bar

BACKSPACE Key

Arrow Keys

[] Key

DEL Key

Table 6-1 Keyboard Conventions

Function

These are selection keys that perform the same

Local Management function. For example, “Press

ENTER” means that you can press either ENTER or RETURN, unless this manual specifically instructs you otherwise.

This key allows an escape from a Local

Management screen without saving changes. For example, “Press ESC twice” means the ESC key must be pressed quickly two times.

These keys cycle through selections in some Local

Management fields. Use the SPACE bar to cycle forward through selections and use BACKSPACE to cycle backward through selections.

These are navigation keys. Use the UP-ARROW,

DOWN-ARROW, LEFT-ARROW, and

RIGHT-ARROW keys to move the screen cursor.

For example, “Use the arrow keys” means to press whichever arrow key moves the cursor to the desired field on the Local Management screen.

This key decreases values from a Local

Management increment field. For example, “Press

[]” means to press the minus sign key.

The DEL (Delete) key removes characters from a

Local Management field. For example, “Press

DEL” means to press the Delete key.

6-2 8H02-16 User’s Guide

Accessing Local Management

6.3

ACCESSING LOCAL MANAGEMENT

Perform the following steps to access Local Management:

1. Turn on the terminal. Press ENTER (up to four times) until the

8H02-16 Local Management Password screen, Figure 6-1, appears.

Event Message Line

8H02-16 LOCAL MANAGEMENT

CABLETRON Systems, Incorporated

P.O.Box 5005

Rochester, NH 03866-5005 USA

(603) 332-9400

(c) Copyright CABLETRON Systems, Inc, 1996

Device Serial Number:

Device Hardware Revision:

Device Firmware Revision:

Device BOOTPROM Revision:

XX.XX.XX

XX

XX.XX.XX

XX.XX.XX

Enter Password:

Figure 6-1 The 8H02-16 Local Management Password Screen

174212

8H02-16 User’s Guide 6-3

Chapter 6: Local Management

2. Enter the Password and press ENTER. The default Super-User access password is “public” or press ENTER.

NOTE

The user’s password is one of the community names specified in the SNMP Community Names screen. Access to certain

Local Management capabilities depends on the degree of

access accorded that community name. Refer to Section 6.7.

• If an invalid password is entered, the terminal beeps and the cursor returns to the beginning of the password entry field.

• Entering a valid password causes the associated access level to display at the bottom of the screen and the Device Menu screen to appear.

• If no activity occurs for several minutes, the Password screen reappears and the password has to be reentered.

\

6.3.1

Navigating Local Management Screens

The 8H02-16 Local Management consists of a series of menu screens.

Figure 6-2 shows the hierarchy of the 8H02-16 Local Management

screens.

Device

Configuration

Menu

General Configuration

SNMPCommunity Names

SNMP Traps

Bridge Configuration

Password

Device

Menu

Device

Statistics

Menu

Device Specific

Configuration Menu

Bridge Statistics

Port Statistics

Full Duplex

Configuration

System

Resources

High Speed

Interface

Configuration

Flash Download

Clear NVRAM

Port Redirect

Function

Network Tools

Figure 6-2 Hierarchy of Local Management Screens

174243

6-4 8H02-16 User’s Guide

Accessing Local Management

6.3.2

Selecting Local Management Menu Screen Items

Select items on a menu screen by performing the following steps:

1. Use the arrow keys to highlight a menu item.

2. Press ENTER. The selected menu item appears on the screen.

6.3.3

Exiting Local Management Screens

Exit a Local Management screen by performing the following steps:

1. Use the arrow keys to highlight the RETURN command at the bottom of the Local Management screen.

2. Press ENTER. The previous screen in the Local Management hierarchy appears.

NOTE

The user can also exit Local Management screens by pressing

ESC twice. This exit method does not warn about unsaved changes and all unsaved changes will be lost.

3. Exit from 8H02-16 Local Management by repeating steps 1 and 2 until the Device Menu screen appears.

4. Use the arrow keys to highlight the RETURN command at the bottom of the Device Menu screen.

5. Press ENTER. The Password screen appears and the session ends.

8H02-16 User’s Guide 6-5

Chapter 6: Local Management

6.4

DEVICE MENU SCREEN

The Device Menu screen is the access point for all Local Management

screens. Figure 6-3 shows the Device Menu screen.

Event Message Line

Device Name: 8H02-16

8H02-16 LOCAL MANAGEMENT

Device Menu

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

DEVICE CONFIGURATION

DEVICE STATISTICS

NETWORK TOOLS

Figure 6-3 Device Menu Screen

RETURN

174213

6-6 8H02-16 User’s Guide

Device Menu Screen

The following explains each Device Menu screen field as shown in

Figure 6-3:

DEVICE CONFIGURATION

The Device Configuration screen provides access to the Local

Management screens that are used to configure the 8H02-16 and also to the Device Specific Configuration Menu screen. The Device Specific

Configuration Menu screen provides access to the screens that allow the user to check the 8H02-16 resources and set operating parameters specific

to each port. For details about the Device Configuration Menu screen, refer to Section 6.5. For details about the Device Specific Configuration

Menu screen, refer to Section 6.11.

DEVICE STATISTICS

The Device Statistics screen provides statistics and performance information for the 8H02-16. For details about this screen, refer to

Section 6.18.

NETWORK TOOLS

The Network Tools function resides on the 8H02-16 and consists of a series of commands that allow the user to access and manage network

devices. Section 6.21 explains how to use the Network Tools utility.

If the terminal is idle for several minutes, the Password screen reappears and the password has to be reentered.

8H02-16 User’s Guide 6-7

Chapter 6: Local Management

6.5

DEVICE CONFIGURATION MENU SCREEN

The Device Configuration Menu screen, Figure 6-4, provides access to

Local Management screens that allow the user to configure and monitor operating parameters, modify SNMP community names, set SNMP traps, configure bridge parameters and configure 8H02-16 ports.

Event Message Line

Device Name: 8H02-16

8H02-16 LOCAL MANAGEMENT

Device Configuration Menu

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

GENERAL CONFIGURATION

SNMP COMMUNITY NAMES

SNMP TRAPS

BRIDGE CONFIGURATION

DEVICE SPECIFIC CONFIGURATION

Figure 6-4 Device Configuration Menu Screen

RETURN

174242

6-8 8H02-16 User’s Guide

Device Configuration Menu Screen

The following explains each Device Configuration menu screen as shown

in Figure 6-4:

GENERAL CONFIGURATION

The General Configuration screen allows the user to monitor and configure operating parameters for the 8H02-16. For details, refer

to Section 6.6.

SNMP COMMUNITY NAMES

The SNMP Community Names screen allows the user to change or review the community names used as access passwords for local management

operation. For details, refer to Section 6.7.

SNMP TRAPS

The SNMP Traps screen provides display and configuration access to the table of IP addresses used for trap destinations and associated community

names. For details, refer to Section 6.8.

BRIDGE CONFIGURATION

The Bridge Configuration screen provides basic setup options for making

a bridge operational in the network. For details, refer to Section 6.10.

DEVICE SPECIFIC CONFIGURATION

The Device Specific Configuration screen allows the user to select one of four screens to configure ports or check system resources specific to the

8H02-16. For details, refer to Section 6.11.

8H02-16 User’s Guide 6-9

Chapter 6: Local Management

6.6

GENERAL CONFIGURATION SCREEN

The General Configuration screen, Figure 6-5, allows the user to set the

system date and time, IP addresses and Subnet Masks, the Default

Interface and Default Gateway, the TFTP Gateway IP address, and the

COM port configuration.

Access the General Configuration screen from the Device Configuration

Menu screen by using the arrow keys to highlight the General

Configuration option and pressing ENTER. The General Configuration

screen, Figure 6-5, appears.

Event Message Line

Device Name: 8H02-16

MAC Address:

IP Address:

Subnet Mask:

Default Gateway:

Default Interface:

TFTP Gateway IP Addr:

8H02-16 LOCAL MANAGEMENT

General Configuration

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

00-00-ID-00-00-00

0.0.0.0

0.0.0.0

NONE DEFINED

NONE DEFINED

0.0.0.0

Device Date:

Device Time:

Screen Refresh Time:

Screen Lockout Time:

10/11/93

14:23:00

30 sec.

15 min.

Com 1: [ENABLED] Application: [LM]

SAVE RETURN

174215

Figure 6-5 General Configuration Screen

The following briefly explains each General Configuration screen field:

MAC Address (Read-Only)

Displays the physical address of the 8H02-16.

IP Address (Modifiable)

The display allows the IP address to be set for the 8H02-16.

6-10 8H02-16 User’s Guide

General Configuration Screen

Subnet Mask (Modifiable)

Displays the subnet mask for the 8H02-16. A subnet mask “masks out” the network bits of the IP address by setting the bits in the mask to 1 when the network treats the corresponding bits in the IP address as part of the network or subnetwork address, or to 0 if the corresponding bit identifies the host. For details about how to change the Subnet Mask from its default

value, refer to Section 6.6.2.

Default Gateway (Modifiable)

Displays the default gateway for the 8H02-16. This field is not defined until an appropriate value is entered. For details about why and how to set

the Default Gateway, refer to Section 6.6.3.

Default Interface (Modifiable)

Displays the default interface for the 8H02-16 default gateway. The field defaults to NONE. For details about when and how to set the Default

Interface, refer to Section 6.6.4.

TFTP Gateway IP Addr. (Modifiable)

Displays and allows the user to set the TFTP Gateway IP address for the

8H02-16. To set the TFTP Gateway IP address, refer to Section 6.6.5.

Device Date (Modifiable)

Contains a value that the device recognizes as the current date. To set a

new device date, refer to Section 6.6.6.

Device Time (Modifiable)

Contains a value that the device recognizes as the current time. To enter a

new time, refer to Section 6.6.7.

Screen Refresh Time (Modifiable)

Contains the rate at which the screens are updated. This setting determines how frequently (in seconds) information is updated on the

screen. To enter a new update time, refer to Section 6.6.8.

8H02-16 User’s Guide 6-11

Chapter 6: Local Management

Screen Lockout Time (Modifiable)

Contains the maximum number of minutes that the Local Management application displays a module’s screen while awaiting input or action from a user. For example, if the number 5 is entered in this field, the user has up to five minutes to respond to each of the specified module’s Local

Management screens. In this example, after five minutes of “idleness” (no input or action), the terminal “beeps” five times, the Local Management application terminates the session, and the display returns to the Password

screen. To enter a new lockout time, refer to Section 6.6.9.

Com 1 (Modifiable)

This field allows the user to enable or disable the COM port. The selection toggles between ENABLE and DISABLE. The default is

ENABLED. For details about setting up the COM port, refer to

Section 6.6.10.

Application (Modifiable)

Displays the application set for the COM port. This field allows the user to set the application that the COM port supports. The field steps between

LM (Local Management), SLIP (Serial Line Interface Protocol), PPP

(Point-to-Point Protocol), or UPS (Uninterruptible Power Supply).

The UPS setting allows the COM port to be used to monitor an American

Power Conversion Smart Uninterruptible Power Supply (UPS).

The baud rate setting for LM is automatically sensed. For UPS, the baud rate is automatically set to 2400. The baud rate must be manually set in the Baud Rate field if either PPP or SLIP is selected.

The default setting is LM. For details about how to configure the COM port for various applications, refer

to Section 6.6.10.

Baud Rate (Modifiable)

Displays the baud rate setting of the device attached to the 8H02-16 through the COM port. The field steps between 2400, 4800, 9600 or

19,200. This selection is only available if SLIP or PPP is selected in the

Application field.

6-12 8H02-16 User’s Guide

NOTE

General Configuration Screen

6.6.1

Setting the IP Address

Set the IP address by performing the following steps:

1. Use the arrow keys to highlight the IP Address field.

2. Enter the IP address into this field using Decimal Dotted Notation

(DDN) format.

For example: 134.141.79.120

3. Press ENTER. If the IP address is a valid format, the cursor returns to the beginning of the IP address field. If the entry is not valid, the Event

Message Line displays “INVALID IP ADDRESS OR FORMAT

ENTERED”. Local Management does not alter the current value and refreshes the IP address field with the previous value.

4. Use the arrow keys to highlight the SAVE command, then press

ENTER. The “SAVED OK” message appears indicating that the changes have been saved to memory.

The device automatically resets after a new IP address is saved.

6.6.2

Setting the Subnet Mask

If the management workstation that is to receive SNMP traps from the

8H02-16 is located on a separate subnet, the subnet mask for the 8H02-16 must be changed from its default.

To change the subnet mask from its default, perform the following steps:

1. Use the arrow keys to highlight the Subnet Mask field.

2. Enter the subnet mask into this field using Decimal Dotted Notation

(DDN) format.

For example: 255.255.0.0

8H02-16 User’s Guide 6-13

Chapter 6: Local Management

3. Press ENTER. If the subnet mask is valid, the cursor returns to the beginning of the Subnet Mask field. If the entry is not valid, the Event

Message Line displays “INVALID SUBNET MASK OR FORMAT

ENTERED”. Local Management does not alter the current value, but it does refresh the Subnet Mask field with the previous value.

4. Use the arrow keys to highlight the SAVE command.

5. Press ENTER. The Event Message Line at the top of the screen displays “SAVED OK”, and the device resets.

6.6.3

Setting the Default Gateway

If the SNMP management station is located on a different IP subnet than the 8H02-16, a default gateway must be specified. When an SNMP Trap is generated, the 8H02-16 sends the Trap to the default gateway. To set the default gateway, perform the following steps:

1. Use the arrow keys to highlight the Default Gateway field.

2. Enter the IP address of the default gateway using the DDN format.

For example: 134.141.79.121

3. Press ENTER. If the default gateway entered is a valid format, the cursor returns to the beginning of the Default Gateway field. If the entry is not valid, the Event Message Line displays “INVALID

DEFAULT GATEWAY OR FORMAT ENTERED”. Local

Management does not alter the current value, but it does refresh the

Default Gateway field with the previous value.

4. Use the arrow keys to highlight the SAVE command.

5. Press ENTER. The Event Message Line at the top of the screen displays “SAVED OK”.

6-14 8H02-16 User’s Guide

General Configuration Screen

6.6.4

Setting the Default Interface

The default interface is the interface channel for the designated default gateway. Set the default interface by performing the following steps:

1. Use the arrow keys to highlight the Default Interface field.

2. Enter the interface number for the default gateway in this field with a value from 1 to 16.

3. Press ENTER. If the interface number entered is a valid format, the cursor returns to the beginning of the Default Interface field. If the entry is not valid, the Event Message Line displays “PERMISSIBLE

RANGE: 1...16”. Local Management does not alter the current value, but it does refresh the Default Interface field with the previous value.

4. Use the arrow keys to highlight the SAVE command.

5. Press ENTER. The Event Message Line at the top of the screen displays “SAVED OK”.

6.6.5

Setting the TFTP Gateway IP Address

If the network TFTP server is located on a different IP subnet than the

8H02-16, a gateway IP address should be specified. To set the TFTP gateway IP address, perform the following steps:

1. Use the arrow keys to highlight the TFTP Gateway IP Address field.

2. Enter the IP address of the TFTP gateway using the DDN format.

For example: 134.141.80.122

3. Press ENTER. If the TFTP gateway IP address entered is a valid format, the cursor returns to the beginning of the TFTP Gateway IP

Address field. If the entry is not valid, the Event Message Line displays “INVALID TFTP GATEWAY IP ADDRESS OR FORMAT

ENTERED”. Local Management does not alter the current value, but it does refresh the TFTP Gateway IP Address field with the previous value.

4. Use the arrow keys to highlight the SAVE command.

5. Press ENTER. The Event Message Line at the top of the screen displays “SAVED OK”.

8H02-16 User’s Guide 6-15

Chapter 6: Local Management

6.6.6

Setting the Device Date

To set the system date, perform the following steps:

1. Use the arrow keys to highlight the Device Date field.

2. Enter the date in a MM/DD/YY format.

NOTE

It is not necessary to add separators between month, day, and year numbers, as long as each entry uses two numeric characters. For example, to set the date to 03/17/96, type

“031796” in the Device Date field.

3. Press ENTER to set the system calender to the date in the input field.

4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER.

If the date entered is a valid format, the Event Message Line at the top of the screen displays “SAVED OK”. If the entry is not valid, Local

Management does not alter the current value, but it does refresh the

Device Date field with the previous value.

6.6.7

Setting the Device Time

To set the device clock, perform the following steps:

1. Use the arrow keys to highlight the Device Time field.

2. Enter the time in a 24-hour format, HH:MM:SS.

NOTE

When entering the time in the system time field, separators between hours, minutes, and seconds do not need to be added as long as each entry uses two numeric characters. For example, to set the time to 6:45 A

.

M ., type “064500” in the

Device Time field.

3. Press ENTER to set the system clock to the time in the input field.

4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER.

6-16 8H02-16 User’s Guide

General Configuration Screen

If the time entered is a valid format, the Event Message Line at the top of the screen displays “SAVED OK”. If the entry is not valid, Local

Management does not alter the current value and refreshes the Device

Time field with the previous value.

6.6.8

Entering a New Screen Refresh Time

The screen refresh time is set from 3 to 99 seconds with a default of 3 seconds. To set a new screen refresh rate, perform the following steps:

1. Use the arrow keys to highlight the Screen Refresh Time field.

2. Enter a number from 3 to 99.

3. Press ENTER to set the refresh rate to the time in the input field.

4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER.

If the time entered is within the 3 to 99 seconds range, the Event Message

Line at the top of the screen displays “SAVED OK”. If the entry is not valid, Local Management does not alter the current setting, but it does refresh the Screen Refresh Time field with the previous value.

6.6.9

Setting the Screen Lockout Time

The screen lockout time can be set from 1 to 30 minutes with a default of

15 minutes. To set a new lockout time, perform the following steps:

1. Use the arrow keys to highlight the Screen Lockout field.

2. Enter a number from 1 to 30.

3. Press ENTER to set the lockout time in the input field.

4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER.

If the time entered is within the 1 to 30 minutes range, the Event Message

Line at the top of the screen displays “SAVED OK”. If the entry is not valid, Local Management does not alter the current setting, but it does refresh the Screen Lockout Time field with the previous value.

8H02-16 User’s Guide 6-17

Chapter 6: Local Management

6.6.10

Configuring the COM Port

!

C AUT IO N

Before altering the COM port settings, ensure that a valid IP

address is set for this device (Refer to Section 6.6.1, Setting

the IP Address). Read this entire COM port configuration

section before changing the settings of the COM port.

The 8H02-16 COM port supports the following applications:

NOTE

Refer to the Release Notes included with the 8H02-16 to verify which COM Port applications are currently supported.

• Local Management connections

• American Power Conversion (APC) Uninterruptible Power Supply

(UPS) connections

• Telnet connections using SLIP or PPP

To enable the COM port and select a supported application, refer to

Section 6.6.11 and Section 6.6.12.

6-18 8H02-16 User’s Guide

General Configuration Screen

6.6.11

Enabling the COM Port

To enable the COM port, perform the following steps:

1. Use the arrow keys to highlight the Com 1 field.

!

C AUT IO N

Do NOT disable or alter the settings of the COM port while operating the current Local Management connection through a terminal. Altering the COM port settings disconnects the Local

Management terminal from the port, and ends the Local

Management session.

If the 8H02-16 was previously assigned a valid IP address, reenter Local Management by establishing a Telnet connection to the device. If the device does not have a valid IP address, reset NVRAM on the 8H02-16 (refer to Appendix C) in order to reestablish COM port communications.

2. Press the SPACE bar to choose either ENABLE or DISABLE.

!

C AUT IO N

If the COM port is reconfigured without a valid IP address set

on the device, the message shown in Figure 6-6 appears.

Do not continue unless the outcome of the action is fully understood.

8H02-16 User’s Guide 6-19

Chapter 6: Local Management

WARNING

THE COM PORT HAS BEEN RECONFIGURED AND THERE IS NO IP

ADDRESS SET FOR THIS DEVICE. YOU WILL NO LONGER BE ABLE

TO MANAGE THIS BOARD. DO YOU STILL WISH TO RECONFIGURE

THIS COM PORT?

YES NO

174252

Figure 6-6 COM Port Warning Screen

3. Use the arrow keys to highlight YES. Press ENTER.

4. If you ENABLE the port, refer to Section 6.6.12. Otherwise, use the

arrow keys to highlight SAVE at the bottom of the screen, then press

ENTER.

5. When the message “SAVED OK” appears, the edits are saved.

!

C AUT IO N

Exiting without saving causes the message “NOT SAVED --

PRESS SAVE TO KEEP CHANGES” to appear. Exiting without saving causes all edits to be lost.

6-20 8H02-16 User’s Guide

General Configuration Screen

6.6.12

Changing the COM Port Application

After enabling the COM port as described in Section 6.6.11, select one of

the four applications supported by the COM port: LM, SLIP, PPP or UPS.

The default application is LM.

!

C AUT IO N

If the COM port is reconfigured without a valid IP address set

on the device, the message shown in Figure 6-6 appears. Do

not continue unless the outcome of the action is fully understood.

To change the COM port application:

1. Use the arrows keys to highlight the Application field.

2. Use the SPACE bar or BACKSPACE to step through the available

settings until the required operation appears. Table 6-2 lists the

available settings and their corresponding applications.

Setting

[LM]

[UPS]

[SLIP]

[PPP]

Table 6-2 COM Port Application Settings

Application

Local Management Session

APC Power Supply SNMP Proxy

Serial Line Interface Protocol

Point-to-Point Protocol

3. Press ENTER to accept the application.

4. Use the arrow keys to highlight SAVE at the bottom of the screen, then press ENTER.

5. When the message “SAVED OK” appears, the edits are saved.

8H02-16 User’s Guide 6-21

Chapter 6: Local Management

6.6.13

Setting the Baud Rate

If SLIP or PPP is selected in the previous section, a separate field appears to the right of the Application field that allows the user to select the baud rate. Change the baud rate setting as follows:

1. Use the arrow keys to highlight the Baud Rate field.

2. Use the SPACE bar or BACKSPACE to step to the correct setting.

3. Press ENTER to accept the baud rate.

4. Use the arrow keys to highlight SAVE at the bottom of the screen, then press ENTER.

5. When the message “SAVED OK” appears, the edits are saved.

6-22 8H02-16 User’s Guide

NOTE

SNMP Community Names Screen

6.7

SNMP COMMUNITY NAMES SCREEN

The SNMP Community Names option allows the user to set Local

Management community names. Community names act as passwords to

Local/Remote Management and are agents of security access to the

8H02-16. Access to the 8H02-16 is controlled by enacting any of three different levels of security authorization (read-only, read-write, and super-user).

Super-User access gives the user full management privileges, allows existing passwords to be changed, and all modifiable

MIB objects for the Cabletron Container MIB and Internet

MIB-II to be edited.

Access the SNMP Community Names screen from the Device

Configuration Menu screen by using the arrow keys to highlight the

SNMP Community Names option and pressing ENTER. The SNMP

Community Names screen, Figure 6-7, appears.

Event Message Line

Device Name: 8H02-16

8H02-16 LOCAL MANAGEMENT

SNMP Community Names

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Community Name public public public

Access Policy read-only read-write super-user

SAVE RETURN

174216

Figure 6-7 The SNMP Community Names Screen

8H02-16 User’s Guide 6-23

Chapter 6: Local Management

The following explains each SNMP Community Names screen field:

Community Name (Modifiable)

Displays the user-defined name through which a user accesses the

8H02-16 Local Management. Any community name assigned here acts as a password to Local Management.

Access Policy (Read-Only)

Indicates the access status accorded each community name. Possible selections are as follows:

Read-Only (RO) This community name gives the user extended read-only access to 8H02-16 MIB objects, and excludes access to security-protected fields of read-write or super-user authorization.

Read-Write (RW) This community name gives the user read and write access to the 8H02-16 MIB objects, excluding security protected fields for super-user access only.

Super-User (SU) This community name gives the user read-write access to the 8H02-16 MIB objects and allows the user to change all modifiable parameters including community names, IP addresses, traps, and SNMP objects.

6-24 8H02-16 User’s Guide

NOTE

SNMP Community Names Screen

6.7.1

Establishing Community Names

The password used to access Local Management at the Password Screen must have Super-User access in order for edits in the SNMP Community

Names screen to take effect. Using a password with Read-Only or

Read-Write access does not allow the user to edit the SNMP Community

Names screen.

Any community name assigned in the SNMP Community

Names screen is a password to its corresponding level of access to Local Management. The community name assigned

Super-User access is the only one that gives the user complete access to Local Management.

To establish community names, proceed as follows:

1. Use the arrow keys to highlight the Community Name field adjacent to the selected access level.

2. Enter the password in the field (maximum 31 characters).

3. Press ENTER.

4. Repeat steps 1 through 3 to modify the other community names.

5. Use the arrow keys to highlight SAVE at the bottom of the screen and press ENTER. The message “SAVED OK” appears. The community names are saved to memory and their access modes implemented.

NOTE

Exiting without saving causes a “NOT SAVED?” message to display above the SAVE command. Edits will be lost if they are not saved before exiting.

6. To exit the screen, use the arrow keys to highlight RETURN and press

ENTER.

8H02-16 User’s Guide 6-25

Chapter 6: Local Management

6.8

SNMP TRAPS SCREEN

Since the 8H02-16 is an SNMP compliant device, it sends messages to multiple Network Management Stations to alert users of status changes.

The SNMP Traps screen is shown in Figure 6-8.

Access the SNMP Traps screen from the Device Configuration Menu screen by using the arrow keys to highlight the SNMP Traps option and

pressing ENTER. The SNMP Traps screen shown in Figure 6-8 appears.

Event Message Line

Device Name: 8H02-16

Trap Destination

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

8H02-16 LOCAL MANAGEMENT

SNMP Traps

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Trap Community Name public public public public public public public public

Enable Traps

[NO]

[NO]

[NO]

[NO]

[NO]

[NO]

[NO]

[NO]

SAVE RETURN

174217

Figure 6-8 The SNMP Traps Screen

The following explains each field of the SNMP Traps screen.

Trap Destination (Modifiable)

Indicates the IP address of the workstation to receive trap alarms up to eight destinations.

Trap Community Name (Modifiable)

Displays the Community Name included in the trap message sent to the

Network Management Station with the associated IP address.

6-26 8H02-16 User’s Guide

Configuring the Trap Table

Enable Traps (Toggle)

Enables transmission of the traps to the network management station with the associated IP address. This field toggles between [YES] and [NO].

6.9

CONFIGURING THE TRAP TABLE

To configure the Trap table, proceed as follows:

1. Using the arrow keys, highlight the appropriate Trap Destination field.

2. Enter the IP Address of the workstation that is to receive traps. IP address entries must follow the DDN format.

For example: 134.141.79.121

3. Press ENTER. If an invalid entry is entered “INVALID IP

ENTERED” is displayed in the Event Message Line.

4. Using the arrow keys, highlight the Trap Community Name field.

Enter the community name.

5. Press ENTER.

6. Using the arrow keys, highlight the Enable Traps field. Press the

SPACE bar to choose either [YES] (send alarms from the 8H02-16 to the workstation), or [NO] (prevent alarms from being sent).

7. Using the arrow keys, highlight the SAVE option and press ENTER.

The message “SAVED OK” appears on the screen.

NOTE

Exiting without saving causes a “NOT SAVED?” message to appear above the SAVE command. Edits will be lost if they are not saved before exiting.

8. To exit the screen, use the arrow keys to highlight RETURN and press

ENTER.

The designated workstations now receive traps from the 8H02-16.

8H02-16 User’s Guide 6-27

Chapter 6: Local Management

6.10

BRIDGE CONFIGURATION SCREEN

The Bridge Configuration screen, Figure 6-9, provides the basic setup

options to make a bridge operational in your network.

Access the Bridge Configuration screen from the Device Configuration menu by using the arrow keys to highlight the Bridge Configuration option and pressing ENTER. The Bridge Configuration screen,

Figure 6-9, appears.

Event Message Line

Device Name: 8H02-16

Port #

4

5

6

7

8

1

2

3

SAVE

Bridge Address: 00-00-1D-00-00-00

Number of Ports: 16

MAC Address

00-00-1D-00-00-00

00-00-1D-00-00-01

00-00-1D-00-00-02

00-00-1D-00-00-03

00-00-1D-00-00-04

00-00-1D-00-00-05

00-00-1D-00-00-06

00-00-1D-00-00-07

8H02-16 LOCAL MANAGEMENT

Bridge Configuration

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Type of STA: [DEC]

State learning listening standby learning listening standby listening listening

[9-16]

Status

[ENABLED]

[DISABLED]

[ENABLED]

[DISABLED]

[ENABLED]

[DISABLED]

[ENABLED]

[DISABLED]

RETURN

174218

Figure 6-9 Bridge Configuration Screen

The following describe each field of the Bridge Configuration screen:

Bridge Address (Read-Only)

Displays the MAC address of the bridge.

Number of Ports (Read-Only)

Displays the total number of bridged ports on the 8H02-16.

6-28 8H02-16 User’s Guide

Bridge Configuration Screen

Type of STA (Toggle)

Allows the user to set the method that bridges use to decide which bridge is the controlling (Root) bridge when two or more bridges exist in parallel

(Spanning Tree Algorithm). Valid entries include IEEE, DEC, and None.

To set the STA, refer to Section 6.10.1.

Port # (Read-Only)

Lists each bridge port on the device. If the number of ports is greater than eight, then the additional ports are listed on subsequent screens.

MAC Address (Read-Only)

Displays the hardware address assigned to each listed port.

State (Read-Only)

Disabled: Management disabled this interface. No traffic is received or forwarded while the interface is disabled.

Learning: The bridge is learning the network address of this interface. The bridge enters the learning state when the Transparent Database is created

(during start-up or after being deleted), or when the Spanning Tree

Algorithm detects a network topology change.

Listening: The bridge is not adding information to the Transparent

Database. The bridge is monitoring BPDU traffic while preparing to move from the learning to the forwarding state.

Forwarding: The bridge is on line and this interface is forwarding traffic.

Blocking: This interface will not forward any traffic through the bridge.

Status (Toggle)

Allows the user to disable or enable a port by setting the status of the listed interface to either ENABLED or DISABLED. To set the port status,

refer to Section 6.10.2.

8H02-16 User’s Guide 6-29

Chapter 6: Local Management

6.10.1

Selecting the STA

The STA setting allows the user to set the method that the bridges use to decide which is the controller (Root) bridge when two or more bridges are in parallel (Spanning Tree Algorithm). The available selections are IEEE,

DEC, and NONE.

To set the STA, proceed as follows:

1. Use the arrow keys to highlight the Type of STA field.

2. Use the SPACE bar to step to the appropriate setting (IEEE, DEC, or

NONE).

3. Use the arrow keys to highlight the SAVE command at the bottom of the screen.

4. Press ENTER. The message “SAVED OK” is displayed.

6.10.2

Setting (Enabling or Disabling) the Port Status

To set the status of an interface (port), proceed as follows:

1. Use the arrow keys to highlight the Status field of the port.

2. Use the SPACE bar to toggle to either ENABLE or DISABLE.

3. Use the arrow keys to highlight the SAVE command at the bottom of the screen.

4. Press ENTER. The message “SAVED OK” is displayed.

6-30 8H02-16 User’s Guide

Device Specific Configuration Menu Screen

6.11

DEVICE SPECIFIC CONFIGURATION MENU

SCREEN

The Device Specific Configuration Menu screen, Figure 6-10, allows the

user to select one of four screens to configure ports or check system resources specific to the 8H02-16.

Access the Device Specific Configuration Menu screen from the Device

Configuration Menu screen by using the arrow keys to highlight the

Device Specific Configuration Menu option and pressing ENTER. The

Device Specific Configuration Menu screen appears.

Event Message Line

Device Name: 8H02-16

8H02-16 LOCAL MANAGEMENT

Device Specific Configuration Menu

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

FULL DUPLEX CONFIGURATION

SYSTEM RESOURCES

HIGH SPEED INTERFACE CONFIGURATION

FLASH DOWNLOAD

CLEAR NVRAM

PORT REDIRECT FUNCTION

SAVE RETURN

174220

Figure 6-10 Device Specific Configuration Menu Screen

8H02-16 User’s Guide 6-31

Chapter 6: Local Management

The following explains each field of the Device Specific Configuration

Menu screen:

Full Duplex Configuration

The Full Duplex Configuration screen allows each port (1 to 14) to be set for either Standard Ethernet or Full Duplex operation. The screen also indicates whether or not each port is linked to another 10BASE-T device and if that port is enabled.

System Resources

The System Resources screen displays the amount of FLASH memory,

DRAM, or NVRAM installed, details how much memory is available and provides information on 8H02-16 operation.

High Speed Interface Configuration

The High Speed Interface Configuration screen indicates which High

Speed Interface Modules are installed in ports 15 and 16, their current operating mode, and if the ports are Linked. It also permits the

Auto-Negotiation and Advertised Ability features to be enabled or disabled.

FLASH Download

This screen allows the user to download information from FLASH memory and force the 8H02-16 to download a new image file from a

TFTP server.

!

C AUT IO N

Do not proceed with this operation unless the forced download procedure is completely understood.

Clear NVRAM

This screen allows the user to reset NVRAM to the factory default settings. All user-entered parameters such as the IP address and

Community Names are then replaced with the 8H02-16 default configuration settings.

!

C AUT IO N

Do not proceed with this operation unless the Clear NVRAM procedure is completely understood.

6-32 8H02-16 User’s Guide

Full Duplex Configuration Screen

Port Redirect Function

This screen allows the user to redirect traffic from one or multiple ports to a specific destination port.

6.12

FULL DUPLEX CONFIGURATION SCREEN

The Full Duplex Configuration screen, Figure 6-11, allows the user to set ports 1 through 14 for either Standard Ethernet or Full Duplex operation and monitor each port to see whether or not it is enabled and linked to another 10BASE-T device.

Access the Full Duplex Configuration screen from the Device Specific

Configuration Menu screen by using the arrow keys to highlight the Full

Duplex Configuration option in the Device Specific Configuration Menu screen and press ENTER. The Full Duplex Configuration screen (Figure

6-11) appears.

Event Message Line

5

6

7

8

3

4

PORT #

1

2

Device Name: 8H02-16

OPERATION MODE

[STANDARD ENET]

[STANDARD ENET]

[STANDARD ENET]

[STANDARD ENET]

[STANDARD ENET]

[STANDARD ENET]

[STANDARD ENET]

[STANDARD ENET]

8H02-16 LOCAL MANAGEMENT

Full Duplex Configuration

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

LINK STATUS

Link

Link

Link

No Link

Link

Link

Link

Link

PORT STATUS

ENABLED

ENABLED

ENABLED

ENABLED

ENABLED

ENABLED

ENABLED

ENABLED

SAVE Set All Ports: [FULL] [9-14]

Figure 6-11 Full Duplex Configuration Screen

RETURN

RETURN

174221

8H02-16 User’s Guide 6-33

Chapter 6: Local Management

This section explains each field of the Full Duplex Configuration screen.

Operation Mode (Toggle)

Allows the user to set the specified port to transmit and receive data separately or simultaneously. Set this field to one of the following values:

STANDARD ENET – The port is running at 10 Mbps (default) and either transmits data or receives data, but not both at the same time. To

set Ethernet ports for Full Duplex operation, refer to Section 6.12.1.

FULL DUPLEX The port transmits and receives data at the same time (full duplex) and operates at 20 Mbps. To set Ethernet ports for

Full Duplex operation, refer to Section 6.12.1.

Link Status (Read-only)

Indicates whether there is a physical connection from this port to another

10BASE-T device. One of the following values appears:

Link There is a 10BASE-T link signal present; there is a valid physical connection from this port to another 10BASE-T device.

No Link No 10BASE-T link signal present; there is no valid physical connection from this port to another 10BASE-T device.

Port Status (Read-only)

Indicates whether the port was turned on or off administratively. One of the following values is displayed:

ENABLED The port is turned on administratively.

DISABLED The port is turned off administratively.

NOTE

Enabling or disabling ports from the Bridge Configuration

screen is described in Section 6.10.2.

Set All Ports (Toggle)

Ports 1 through 14 can be set all at once to either STANDARD ENET or

FULL DUPLEX from this field.

6-34 8H02-16 User’s Guide

Full Duplex Configuration Screen

[Ports 9-14] (Read-only)

When the Full Duplex Configuration screen appears, the current operation mode and status information are displayed for the first eight ports. This field allows the user to step to a second screen for the same type of information for ports 9 through 14. While on the second screen, this field changes to [Ports 1-8] so the user can navigate back to the first screen.

The user can change the Operation Mode fields while in either the first or second screen.

6.12.1

Setting the Operation Mode

To set one Ethernet port to either Standard Ethernet or Full Duplex operating mode, proceed as follows:

1. Use the arrow keys to highlight the Operation Mode field adjacent to the number of the port that you plan to change.

NOTE

The Operation Mode for the first 8 ports can be changed on the first screen. To display the Operation Mode for Ports 9 through

14, use the arrow keys to highlight the [Ports 9-14] field and press ENTER.

2. Press the SPACE bar until the appropriate mode (FULL DUPLEX or

STANDARD ENET) appears in the field.

3. Use the arrow keys to highlight the SAVE command on the bottom line of the screen.

4. Press ENTER. The message “SAVED OK” is displayed.

To set all 14 Ethernet ports for Full Duplex or Standard Ethernet, proceed as follows:

1. Use the arrow keys to highlight the SET ALL PORTS field.

2. Press the SPACE bar until you see [FULL DUPLEX] or

[STANDARD ENET].

3. Use the arrow keys to highlight the SAVE command on the bottom line of the screen.

4. Press ENTER. The message “SAVED OK” is displayed.

8H02-16 User’s Guide 6-35

Chapter 6: Local Management

6.13

SYSTEM RESOURCES SCREEN

The System Resources screen, Figure 6-12, provides information

concerning the processor used in the 8H02-16 and the amount of FLASH memory, DRAM, and NVRAM that is installed and how much of that memory is available.

Access the System Resources screen from the Device Specific

Configuration Menu screen by using the arrow keys to highlight the

System Resources option and pressing ENTER. The System Resources screen appears.

Event Message Line

8H02-16 LOCAL MANAGEMENT

System Resources

Device Name: 8H02-16

Device Uptime: 0 days 1 hrs 21 mins

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

CPU Type: i960 HX 66Mhz

Flash Memory Installed : 2 MB Available:

DRAM Installed: 4 MB Available:

NVRAM Installed: 32 KB

Available:

XXXXX Bytes

XXXXX Bytes

XXXXX Bytes

Current Switch Utilization: 66%

Peak Switch Utilization: 75%

Reset Peak Switch Utilization: [NO]

CPU Management Reservation: [FULL]

SAVE

RETURN

RETURN

174223

Figure 6-12 System Resources Screen

The following briefly explains each field of the System Resources screen.

Device Uptime (Read-only)

The time in days/hours/minutes that the device has been continuously running.

CPU Type (Read-only)

Indicates the microprocessor used in the 8H02-16.

6-36 8H02-16 User’s Guide

System Resources Screen

Flash Memory Installed (Read-only)

Indicates the amount of FLASH memory installed in the 8H02-16 and how much is currently available.

DRAM Installed (Read-only)

Indicates the amount of DRAM installed in the 8H02-16 and how much of it is currently available.

NVRAM Installed (Read-only)

Indicates the amount of NVRAM installed in the 8H02-16 and how much of it is currently available.

Current Switch Utilization (Read-only)

Shows how much (percentage of capacity) the 8H02-16 is currently being used.

Peak Switch Utilization (Read-only)

Shows the peak percentage of maximum switching capacity, since last reset.

Reset Peak Switch Utilization (Toggle)

May be set to either YES or NO. YES resets the peak utilization.

CPU Management Reservation (Toggle)

May be set to OFF, LIMITED, or FULL.

OFF – During high traffic loads, management is given a low priority and bridging is given the highest priority. Frames are not dropped unless they exceed the maximum throughput for the device. Latency is at a minimum. However, contact with management might be lost.

LIMITED – Management is given a higher priority. Frames may be dropped, and management may be slow.

FULL – Management is given the highest priority. Frames may be dropped. Management is very responsive.

8H02-16 User’s Guide 6-37

Chapter 6: Local Management

6.13.1

Resetting the Peak Switch Utilization

Set the Peak Switch Utilization field to YES or NO as follows:

1. Use the arrow keys to highlight the Peak Switch Utilization field.

2. Press the SPACE bar to select YES or NO.

3. Use the arrows keys to highlight the SAVE command at the bottom of the screen.

4. Press ENTER. The message “SAVED OK” is displayed.

6.13.2

Setting the CPU Management Reservation

To set the CPU Management Reservation to OFF, LIMITED, or FULL, proceed as follows:

1. Use the arrow keys to highlight the CPU Management Reservation field.

2. Press the SPACE bar to select OFF, LIMITED, or FULL.

3. Use the arrow keys to highlight the SAVE command at the bottom of the screen.

4. Press ENTER. The message “SAVED OK” is displayed.

6-38 8H02-16 User’s Guide

High Speed Interface Configuration Screen

6.14

HIGH SPEED INTERFACE CONFIGURATION

SCREEN

The High Speed Interface Configuration screen, Figure 6-13, applies only

to ports 15 and 16. This screen supports the FE-100TX and the FE-100FX

Fast Ethernet Interface Modules that operate at 100 Mbps.

The High Speed Interface Configuration screen displays the types of interfaces installed in ports 15 and 16, their current operating mode, and indicates if the ports are linked. This screen also allows the user to enable or disable Auto-Negotiation and set the Advertised Ability.

The High Speed Interface Configuration screen is accessed from the

Device Specific Configuration Menu screen by using the arrow keys to highlight the High Speed Interface Configuration option and pressing

ENTER. The High Speed Interface Configuration screen appears.

Event Message Line

Device Name: 8H02-16

Port Type

Link Status

Current Oper. Mode

Desired Oper. Mode

Advertised Ability

8H02-16 LOCAL MANAGEMENT

High Speed Interface Configuration

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Port 15

FE-100TX

Link

100Base-TXFD

[Auto-Negotiation]

[100Base-TXFD] [Disabled]

Port 16

N/A

No Link

[N/A]

[N/A]

[N/A]

SAVE RETURN

174224

Figure 6-13 High Speed Interface Configuration Screen

8H02-16 User’s Guide 6-39

Chapter 6: Local Management

The following briefly explains each field of the High Speed Interface

Configuration screen.

Port Type (Read-only)

Displays the name of the interface (FE-100FX or FE-100TX) installed in

ports 15 and 16. Figure 6-13 shows that there is an FE-100TX interface

installed in Port 15 and no interface [N/A] in Port 16.

Link Status (Read-only)

Indicates whether or not there is a physical connection from this port to another 10BASE-T or 100BASE-TX/FX device. One of the following values appears:

Link There is a 10BASE-T or 100BASE-TX/FX link signal present; there is a valid physical connection from this port to another

10BASE-T or 100BASE-TX/FX device.

No Link There is no 10BASE-T or 100BASE-TX/FX link signal present; there is no valid physical connection from this port to another

10BASE-T or 100BASE-TX/FX device.

Current Operational Mode (Read-only)

This field displays the current operating mode of ports 15 and 16.

Depending on whether a 100Base-FX or 100Base-TX is installed, this field displays the following:

• With a 100Base-FX interface: 100Base-FX or 100Base-FXFD (full duplex)

• With a 100Base-TX interface: Unknown, 10Base-T, 10Base-TFD

(full duplex), 100Base-TX, or 100Base-TXFD (full duplex).

Desired Operational Mode (Selectable)

This field allows the user to select the desired operational mode for an interface in port 15 or 16. The field toggles between 100Base-FX and

100Base-FXFD (full duplex) when an FE-100FX is installed.

Section 6.14.1 describes how to configure a port with an FE-100FX.

6-40 8H02-16 User’s Guide

High Speed Interface Configuration Screen

NOTE

In normal operation, the port with an FE-100TX installed automatically establishes a link with the device at the other end of the segment without requiring user setup. However, Local

Management provides the user with the option of manually configuring that port.

If an FE-100TX is installed, the field steps to Auto-Negotiation,

10Base-T, 10Base-TFD (full duplex), 100Base-TX, and 100Base-TXFD

(full duplex). In normal operation, the port with an FE-100TX installed is capable of auto-negotiating the operational mode and no further user

setup is required. Section 6.14.3 describes how to configure an

FE-100TX.

Advertised Ability (Selectable)

During auto-negotiation, the FE-100TX “tells” the device at the other end of the segment what its capabilities are. The capabilities of a port (15 or

16) with an FE-100TX installed are 10Base-T, 10Base-TFD (full duplex mode), 100Base-TX and 100Base-TXFD (full duplex mode). In normal operation, with all capabilities enabled, the FE-100TX “advertises” that it has the ability to operate in any mode. The Network Manager may choose to set up the port so that only a portion of the available capabilities are advertised and the others are disabled. For example, only 100Base-TX and 100Base-TXFD might be enabled so that only devices that operate at

100 Mbps can communicate with that port.

6.14.1

Configuring an FE-100FX in Port 15 or 16

When an FE-100FX is installed in port 15 or 16, it must be manually set to operate in the same technology as the device at the other end of the

connected segment. Section 6.14.2 provides instructions for manually

configuring the port with an FE-100FX interface.

8H02-16 User’s Guide 6-41

Chapter 6: Local Management

6.14.2

Setting the FE-100FX Operational Mode

Use this field to set the active technology. This field toggles between

100Base-FX and 100Base-FXFD (full duplex). To set the active technology through Local Management, proceed as follows:

1. Use the arrow keys to highlight the Desired Operational Mode field.

2. Use the SPACE bar to select 100Base-FX or 100Base-FXFD (full duplex).

3. Press ENTER. The port now operates in the chosen mode.

4. Use the arrow keys to highlight the SAVE command. Press ENTER.

The message “SAVED OK” appears and Local Management saves the changes to memory.

6.14.3

Configuring an FE-100TX in Port 15 or 16

In normal operation, a port (15 or 16) with an FE-100TX interface automatically establishes a link with the device at the other end of the

segment and no user setup is required. Section 6.14.4 and Section 6.14.5

provide instructions for manually configuring the port with an FE-100TX installed.

6.14.4

Setting the FE-100TX Operational Mode

Use this field to set the active technology. This field steps between

Auto-Negotiation, 10Base-T, 10Base-TFD (full duplex), 100Base-TX, and 100Base-TXFD (full duplex). If Auto-Negotiation is selected, the

FE-100TX automatically sets the active technology. To manually set the active technology through Local Management, proceed as follows:

1. Use the arrow keys to highlight the Desired Operational Mode field.

2. Use the SPACE bar to select the desired mode. Press ENTER. If any mode other than Auto-Negotiation is selected, the port only operates in the chosen mode and auto-negotiation is disabled.

3. Use the arrow keys to highlight the SAVE command. Press ENTER.

The message “SAVED OK” appears and Local Management saves the changes to memory. The selected mode is displayed in both the

Desired Operational Mode field and the Current Operational Mode field.

6-42 8H02-16 User’s Guide

High Speed Interface Configuration Screen

6.14.5

Setting the FE-100TX Advertised Ability

In normal operation, a port (15 or 16) with an FE-100TX auto-negotiates to the highest speed possible. Under some circumstances, the Network

Administrator may want the port to advertise only some of the available modes and not operate in other modes. This field steps between 10Base-T,

10Base-TFD (full duplex), 100Base-TX, and 100Base-TXFD (full duplex). To set the advertised ability, proceed as follows:

1. Use the arrow keys to highlight the Advertised Ability field.

2. Use the SPACE bar to select the mode to enable or disable.

3. Use the LEFT-ARROW key to move back to the Advertised Ability selection and use the SPACE bar to select the next mode to enable or disable.

4. Use the RIGHT-ARROW key to move across to the Enable/Disable field to the right of the selection.

5. Use the SPACE bar to select Enable or Disable. Press ENTER.

Continue this process until you have completed enabling or disabling the advertised modes.

6. Use the arrow keys to highlight the SAVE command. Press ENTER.

The message “SAVED OK” appears and Local Management saves the changes to memory.

8H02-16 User’s Guide 6-43

Chapter 6: Local Management

6.15

FLASH DOWNLOAD SCREEN

The Flash Download screen, shown in Figure 6-14, allows the user to

clear the information stored in the 8H02-16 FLASH memory and download a new image file from a TFTP server. The user may also force a download by changing the position of Switch 6 located inside the device.

Refer to Section C.3, Setting the Mode Switch, for details.

Before downloading a new image to the device, load the image onto the network TFTP server.

NOTE

For information on how to setup a workstation as a TFTP server, refer to the specific workstation documentation.

Access the Download screen from the Device Specific Configuration screen by using the arrow keys to highlight the Flash Download option and pressing ENTER. The Flash Download screen appears.

TFTP DOWNLOAD. WILL COMMIT TO FLASH. REBOOT IN PROGRESS...

8H02-16 LOCAL MANAGEMENT

Flash Download

Device Name: 8H02-16 Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Download Method:

Reboot After Download:

TFTP Gateway IP Addr:

Last Image Server IP:

Last Image File Name:

Download Server IP:

Download File Name:

[TFTP]

YES

134.141.79.123

134.141.79.121

/tftpboot/8H02.hex

134.141.79.121

/tftpboot/8H02.hex

EXECUTE

Figure 6-14 Flash Download Screen

RETURN

174249

6-44 8H02-16 User’s Guide

Flash Download Screen

The following briefly explains each field of the Flash Download screen:

Download Method (Selectable)

This field toggles between BOOTP and TFTP. If set for BootP, the device sends out a BootP request to determine the IP address of the TFTP server and the filename of the image to be downloaded. If set for TFTP, the 8H02-16 attempts a TFTP download based on the IP address and filename entered in the fields at the bottom of the Flash Download screen.

Reboot After Download (Read-only)

This field notifies the user that the 8H02-16 will reboot after the download is complete.

TFTP Gateway IP Addr (Selectable)

This field shows the IP address of the TFTP gateway server defined in the

General Configuration screen in Section 6.6.5, Setting the TFTP

Gateway IP Address.

Last Image Server IP (Read-only)

This field shows the IP address of the server used for the previous FLASH

Download.

Last Image File Name (Read-only)

This field shows the complete path and file name of the last image downloaded to FLASH.

If TFTP is selected as the download method (Figure 6-14), the following

two additional fields appear:

Download Server IP (Selectable)

The IP address of the TFTP server to be used for the FLASH download is entered in this field.

Download File Name (Selectable)

The complete path and file name of the new image is entered in this field.

8H02-16 User’s Guide 6-45

Chapter 6: Local Management

6.15.1

Image File Download Using TFTP

Set the 8H02-16 to download to FLASH using TFTP as follows:

1. Use the arrow keys to highlight the Download Method field.

2. Use the SPACE bar to select TFTP.

3. Use the arrow keys to highlight the TFTP Gateway IP Addr field.

4. Set the IP address of the TFTP gateway server (this defaults to the same IP address as that set in the TFTP Gateway IP Addr field on the

General Configuration screen).

5. Use the arrow keys to highlight the Download Server IP field.

6. Enter the IP address of the TFTP server using the DDN format.

For example: 134.141.79.121

7. Use the arrow keys to highlight the Download File Name field.

8. Enter the complete pathway and file name of the image stored on the download server.

For example: /tftpboot/8H02.hex

9. Use the arrow keys to highlight EXECUTE at the bottom of the screen and press ENTER. The message “TFTP DOWNLOAD. WILL

COMMIT TO FLASH. REBOOT IN PROGRESS...” appears in the event message line at the top of the screen and the new image is downloaded into FLASH memory.

6-46 8H02-16 User’s Guide

Flash Download Screen

6.15.2

Image File Download Using BootP

Set the 8H02-16 to download to FLASH using BootP as follows:

1. Use the arrow keys to highlight the Download Method field.

2. Use the SPACE bar to select BOOTP.

3. Use the arrow keys to highlight the TFTP Gateway IP Addr field. Set the IP address of the TFTP gateway server (this defaults to the same

IP address set in the TFTP Gateway IP Addr field in the General

Configuration screen).

4. Use the arrow keys to highlight EXECUTE at the bottom of the screen and press ENTER. The message “BOOTP DOWNLOAD. WILL

COMMIT TO FLASH. REBOOT IN PROGRESS...” appears in the event message line at the top of the screen and the new image is downloaded into FLASH memory.

8H02-16 User’s Guide 6-47

Chapter 6: Local Management

6.16

CLEAR NVRAM SCREEN

!

C AUT IO N

Clearing NVRAM will result in the loss of all user-entered parameters. Do not proceed unless this procedure is completely understood.

The Clear NVRAM screen shown in Figure 6-15 allows the user to clear

all user-entered parameters such as the IP address, Interface

Configuration, COM Port Configuration and Community Names from

NVRAM.

Access the Clear NVRAM screen from the Device Specific Configuration screen by using the arrow keys to highlight the Clear NVRAM screen and pressing ENTER. The Clear NVRAM screen appears.

CLEARING NVRAM. REBOOT IN PROGRESS...

8H02-16 LOCAL MANAGEMENT

Clear NVRAM

Device Name: 8H02-16 Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Clear NVRAM: [YES]

6-48

EXECUTE

Figure 6-15 Clear NVRAM Screen

RETURN

174250

8H02-16 User’s Guide

Clear NVRAM Screen

Clear NVRAM as follows:

1. Use the arrow keys to highlight the Clear NVRAM field.

2. Use the SPACE bar to toggle the field to YES.

3. Use the arrow keys to highlight EXECUTE at the bottom of the screen.

4. Press ENTER. The warning shown in Figure 6-16 is displayed.

WARNING

YOU HAVE ELECTED TO CLEAR NVRAM. THIS WILL CLEAR

ALL SYSTEM DEFAULTS INCLUDING BUT NOT LIMITED TO

IP ADDRESS, INTERFACE CONFIGURATION, AND COM PORT

CONFIGURATION, THEN RESET THE BOARD.

ARE YOU SURE YOU WANT TO CLEAR NVRAM?

YES NO

174251

Figure 6-16 Clear NVRAM Warning Screen

5. Press YES and the message “CLEARING NVRAM. REBOOT IN

PROGRESS...” appears.

6. The 8H02-16 clears NVRAM and reboots. All user-entered parameters default to factory default settings.

8H02-16 User’s Guide 6-49

Chapter 6: Local Management

6.17

PORT REDIRECT FUNCTION SCREEN

The Port Redirect Function screen, Figure 6-17, allows the user to set

each one of the ports 1 through 16 as a source or destination port. A port can be set to have one or more destination ports. For example, port 1 can be set as a source port with three destinations, ports 2, 3, and 4. Traffic from port 1 is then automatically redirected to ports 2, 3, and 4. Port 1 can also serve as a destination port for other ports.

NOTE

Although all traffic from the source port (including errored frames) is sent to the destination port, normal switching is still performed for all frames on the source port.

Access the Port Redirect Function screen from the Device Specific

Configuration Menu screen by using the arrow keys to highlight the Port

Redirect Function option and pressing ENTER. The Port Redirect

Function screen appears.

Event Message Line

Device Name: 8H02-16

8H02-16 LOCAL MANAGEMENT

Port Redirect Function

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Source Port:

1

1

1

2

2

3

3

3

Destination Port:

2

3

4

1

3

4

5

6

Source Port [1]

SAVE

Destination Port [1]

NEXT

Status [ADD]

PREVIOUS

RETURN

RETURN

174222

Figure 6-17 Port Redirect Function Screen

6-50 8H02-16 User’s Guide

Port Redirect Function Screen

The following definitions briefly explain each field of the Port Redirect

Function screen:

Source Port (Read-only)

Shows which ports are currently set as source ports.

Destination Port (Read-only)

Shows which ports are currently set as destination ports.

Source Port [ n] (Selectable)

Allows a selected port [n] to be changed to a source port.

Destination Port [ n] (Selectable)

Allows a selected port [n] to be changed to a destination port.

Status (Selectable)

Allows you to add or delete the source and destination ports selected in the Source Port [n] and Destination Port [n] fields.

6.17.1

Displaying the Source and Destination Entries

There can be more than one Port Redirect Function screen depending on the number of port redirect entries. Each screen displays up to 10 port redirect entries. If there is more than one screen of redirect entries, the

Next and/or Previous command is displayed at the bottom of the screen, allowing the user to navigate to either the next or previous screen.

For example, with three screens of entries, the Next command appears at the bottom of the first screen. In the second screen, the Next and Previous commands are displayed. In the last screen, only the Previous command is displayed.

To display the next screen, use the arrow keys to highlight Next. Press

ENTER and the next screen of entries is displayed.

To display the previous screen, use the arrow keys to highlight Previous.

Press ENTER to view the entries in the previous screen.

8H02-16 User’s Guide 6-51

Chapter 6: Local Management

6.17.2

Changing Source and Destination Ports

Add or delete source port and destination port entries as follows:

1. Use the arrow keys to highlight the Source Port field.

2. Press the SPACE bar or BACKSPACE one or more times to increment or decrement the port number displayed in the brackets [n] until the appropriate port number is displayed.

3. Use the arrow keys to highlight the Destination Port field.

4. Use the SPACE bar or BACKSPACE to step to the appropriate port number for the destination port.

5. Use the arrow keys to highlight the Status field.

6. Use the SPACE bar to select either the ADD or DEL (delete) option.

Press ENTER. This adds or deletes the port selections made in steps 2 and 4 and also updates the screen Source Port and Destination Port list.

NOTE

If more than one port is to be redirected, repeat steps 1 through

6 for each additional setting, then go to step 7 to save all the new settings at once.

7. Use the arrow keys to highlight SAVE at the bottom of the screen.

Press ENTER. The message “SAVED OK” is displayed. This saves the new settings and updates the Source Port and Destination Port read-only fields.

6-52 8H02-16 User’s Guide

Device Statistics Menu Screen

6.18

DEVICE STATISTICS MENU SCREEN

The Device Statistics Menu screen, Figure 6-18, provides access to

screens that allow the user to obtain bridge statistics about frame traffic through each interface and view operating statistics about each port.

Access the Device Statistics Menu from the Device Menu screen by using the arrow keys to highlight the Device Statistics Menu option and pressing ENTER. The Device Statistics Menu screen appears.

Event Message Line

Device Name: 8H02-16

8H02-16 LOCAL MANAGEMENT

Device Statistics Menu

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

BRIDGE STATISTICS

PORT STATISTICS

RETURN

174225

Figure 6-18 Device Statistics Menu Screen

The Device Statistics Menu screen displays the following menu items:

BRIDGE STATISTICS

The Bridge Statistics screen lists the number of frames received, transmitted, filtered, and forwarded by each interface.

PORT STATISTICS

The Port Statistics screen provides the operating statistics of each port on a port-by-port basis.

8H02-16 User’s Guide 6-53

Chapter 6: Local Management

6.19

BRIDGE STATISTICS SCREEN

The Bridge Statistics screen, Figure 6-19, lists the number of frames

received, transmitted, filtered, and forwarded by each interface.

Access the Bridge Statistics screen from the Device Statistics Menu screen by using the arrow keys to highlight the Bridge Statistics option and pressing ENTER. The Bridge Statistics screen appears.

Event Message Line

8

9

10

11

12

6

7

4

5

2

3

Interface #

1

Device Name: 8H02-16

100

100

100

100

100

100

100

100

100

Frames Rcvd

100

100

100

8H02-16 LOCAL MANAGEMENT

Bridge Statistics

Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

100

100

100

100

100

100

100

100

100

Frames Txmtd

100

100

100

0

0

0

0

0

0

0

0

0

Frames Fltrd

0

0

0

100

100

100

100

100

100

100

100

100

Frames Frwded

100

100

100

[13 - 16] RETURN

174226

Figure 6-19 Bridge Statistics Screen

The Bridge Statistics screen displays the following menu items:

Interface # (Read-Only)

Identifies the interface or port number.

Frames Rcvd (Read-Only)

Displays the number of frames received by the interface.

Frames Txmtd (Read-Only)

Displays the number of frames transmitted by the interface.

6-54 8H02-16 User’s Guide

Port Statistics Screen

Frames Fltrd (Read-Only)

Displays the number of frames filtered by the interface.

Frames Frwded (Read-Only)

Displays the number of frames forwarded by the interface.

6.20

PORT STATISTICS SCREEN

Operating statistics for each port, on a port-by-port basis, are viewed

through the Port Statistics screen shown in Figure 6-20.

Access the Port Statistics screen by using the arrow keys to highlight the

Port Statistics option on the Device Statistics Menu screen and pressing

ENTER. The Port Statistics screen appears.

Event Message Line

8H02-16 LOCAL MANAGEMENT

Port Statistics

Device Name: 8H02-16 Firmware Revision: XX.XX.XX

BOOTPROM Revision: XX.XX.XX

Bytes: 7500456

Frames: 6789

Total Errors: 0

Collisions: 0

CRC/Alignment Errors: 0

Undersize Packets: 0

Oversize Packets: 0

Fragments: 0

Jabbers: 0

Broadcasts: 0

Multicasts: 0

Port # xx

Link Status:

Port Type:

Port Status:

Application:

Operation Mode:

No Link

RJ45

ENABLED

BRIDGING

FULL DUPLEX

Port #: RETURN

174228

Figure 6-20 Port Statistics Screen

8H02-16 User’s Guide 6-55

Chapter 6: Local Management

The following definitions explain each field of the Port Statistics screen:

Port # (Selectable)

Indicates the current port for which statistics are displayed. To select a

port, refer to Section 6.20.1.

Bytes (Read-only)

Displays the number of bytes transmitted and received.

Frames (Read-only)

Displays the number of frames transmitted and received.

Total Errors (Read-only)

Displays the total number of errors on this port.

Collisions (Read-only)

Displays the total number of collisions detected on this port.

CRC/Alignment Errors (Read-only)

Displays the number of packets with bad Cyclic Redundancy Checks

(CRC) received from the network. The CRC is a 4-byte field in the data packet that ensures that the data that is received is the same as the data that was originally sent. Alignment errors are due to misaligned packets.

Undersize Packets (Read-only)

Displays the number of packets received whose size was less than the minimum Ethernet frame size of 64 bytes, not including preamble.

Oversize Packets (Read-only)

Displays the number of packets received whose size exceeded 1518 data bytes, not including preamble.

Fragments (Read-only)

Displays the number of received packets that are not the minimum number of bytes in length or received packets that had a bad Frame Check

Sequence (FCS) and were less than 64 bytes in length (excluding framing bits, but including FCS bytes).

Jabbers (Read-only)

Displays the total number of Jabber conditions detected on this port.

6-56 8H02-16 User’s Guide

Port Statistics Screen

Broadcasts (Read-only)

Displays the number of broadcasts transmitted and received.

Multicasts (Read-only)

Displays the number of multicasts transmitted and received.

Link Status (Read-only)

Displays either Link, No Link or N/A.

Port Type (Read-only)

Displays either RJ45 or MMF SC (multimode fiber, SC connector for

FE-100FX port).

Port Status (Read-only)

Indicates the status of the selected port. Possible values are ENABLED and DISABLED.

Application (Read-only)

Displays BRIDGING, indicating that the port is operating as a bridge.

Operation Mode (Read-only)

Displays one of the following values:

Standard Enet – The port can either transmit data or receive data, but not both at the same time. The port is running at 10 Mbps.

Full Duplex – The port can transmit and receive data at the same time.

The port is running at 20 Mbps.

6.20.1

Displaying Port Statistics

To display the statistics for any port, proceed as follows:

1. Use the arrow keys to highlight the Port # field.

2. Press the SPACE bar to increment (or press the DEL (delete) key to decrement) the port number.

3. Press ENTER (neither the Port # field nor the statistics will change until ENTER is pressed).

8H02-16 User’s Guide 6-57

Chapter 6: Local Management

6.21

NETWORK TOOLS

The Network Tools function, shown in Figure 6-21, resides on the

8H02-16 and allows the user to access and manage network devices.

Access the Network Tools screen by using the arrow keys to highlight the

Network Tools option on the Device Menu screen and pressing ENTER.

The Network Tools screen appears.

Welcome to Network Tools

NetTools-> help arp netstat show bridge ping traceroute defroute reset

SPECIAL: done, quit, or exit - Exit from the Network Tools.

For help with a specific command, type 'help <command>'.

NetTools->

090829

Figure 6-21 Network Tools Help Screen

The Network Tools functions are performed using a series of commands.

Entering commands in Network Tools involves typing the command to be executed at the Network Tools prompt, adding any desired or required extensions, and pressing ENTER.

There are two categories of commands in the command set.

• Built-in Commands - Allow the user to access and manage network devices. The commands are: arp, bridge, defroute, netstat, ping,

reset, show, and traceroute.

• Special Commands - Allow the user to exit from Network Tools. The commands are done, exit, and quit.

6-58 8H02-16 User’s Guide

Network Tools

NOTE

The conventions used here to describe Network Tools are as follows:

• Information entered by the user is in helvetica font

• Arguments enclosed by [ ] are required

• Arguments enclosed by < > are optional

• To abort or interrupt a process, press the control key and c key simultaneously, designated, or ^c here.

6.21.1

Built-in Commands

The built-in commands listed in this section activate functions on the LM managed device or devices being accessed through MIB Navigation.

arp:

Syntax:

Description: arp <options>

The arp command provides access to the ARP

(Address Resolution Protocol) cache, enabling you to view cache data, delete entries, or add a static route. Super-User access is required to delete an entry or add a static route.

Each ARP cache entry lists the network

interface that the device is connected to, the device’s network address or IP address, the device’s physical address or MAC address, and the media type of connection to the device.

Media types are displayed as numbers, which stand for the following states:

1 - Other

2 - Invalid entry (cannot ping device, timed out, etc.)

3 - Dynamic route entry

4 - Static route entry (not subject to change)

8H02-16 User’s Guide 6-59

Chapter 6: Local Management

You can specify the arp command without options, or with one of the following options:

Options: -a View cache data

-d Delete an IP address entry. Requires additional arguments: <Interface Number> <IP address>

-s Adds a static entry. Requires additional arguments: <Interface Number> <IP address>

<MAC address>

-f Flush the ARP cache

Example:

NetTools-> arp -a

# Interface

# (SonicInt)

# (SonicInt)

# (SonicInt)

# (SonicInt)

Network Address

122.144.40.111

122.144.48.109

122.144.52.68

122.144.21.43

Physical Address

00.00.0e.12.3c.04

00.00.0e.f3.3d.14

00.00.0e.12.3c.04

00.00.0e.03.1d.3c

Media Type

3(dynamic)

3(dynamic)

3(dynamic)

3(dynamic)

NetTools-> arp -d 1 122.144.52.68

NetTools-> arp -s 1 22.44.2.3 00:00:0e:03:1d:3c

NetTools-> arp -f

051467

6-60 8H02-16 User’s Guide

Network Tools bridge:

Syntax:

Description: bridge [ENABLE/DISABLE] [IFNUM/ALL]

The bridge command allows bridge management to be enabled or disabled at the user’s request, either one at a time or all at once.

Specifying a single interface number will affect the bridging status of that interface, while specifying ALL will affect every interface.

Not Applicable Options:

Example: defroute:

Syntax:

Description:

Options:

Example:

NetTools-> bridge disable all

NetTools-> bridge enable 1

NetTools-> bridge disable 1

051467 defroute [interface number] [IP address]

The defroute command allows the user to view, set or delete the default IP route to a managed device through the specified interface.

Not Applicable

NetTools-> defroute 2 147.152.42.32

051469

8H02-16 User’s Guide 6-61

Chapter 6: Local Management netstat:

Syntax:

Description:

Options: netstat [option]

The netstat command provides a display of general network statistics for the managed device. The netstat command must be used with one of the two display options.

-i Displays status and capability information for each interface

-r Displays routing information for each interface

Example:

NetTools-> netstat -i

Interface + Description

# 1 (ethernet -csmacd)

# 2 (ethernet - csmacd)

# 3 (ethernet - csmacd)

# 4 (ethernet - csmacd)

MTU

1514

1514

1514

1514

NetTools-> netstat -r

Destination Next-hop

# Default Route

# 134.141.0.0

# 134.141.0.0

DirectConnection

DirectConnection

DirectConnection

Speed Admin Oper

10000000

10000000

10000000

10000000 up up up up up up up up

MAC Addr

0x00 0x00 0x1d 0x07 0x50 0x0e

0x00 0x00 0x1d 0x07 0x50 0x0f

0x00 0x00 0x1d 0x07 0x50 0x10

0x00 0x00 0x1d 0x07 0x50 0x11

Interface

1

2

3

051470

6-62 8H02-16 User’s Guide

Network Tools ping:

Syntax:

Description: ping [IP address]

The ping command generates an outbound ping request to check the status (alive/not alive) of a device at a specified IP address.

Not Applicable Options:

Example:

NetTools-> ping 122.144.40.10

122.144.40.10 is alive

051471 reset:

Syntax:

Description: reset

The reset command allows a soft reset of the device. The user will be queried to confirm the reset command to insure against unwanted resets.

!

C AUT IO N

The Network Tools connection to the device will be terminated upon execution of this command.

Options:

Example:

Not Applicable

NetTools-> reset

174245

8H02-16 User’s Guide 6-63

Chapter 6: Local Management show:

Syntax:

Description:

Options:

Example: show [PROTOCOL] [TABLE]

The show command displays information concerning various components of the device.

Protocols currently supported are IP, IPX,

DECnet, and AppleTalk. Components of those protocols that are currently supported are ARP caches, route tables, FIB tables, server tables, and interface tables. The number of valid entries in the table will be displayed at the end of the table display.

Not Applicable

NetTools-> show Appletalk interfaces

# Interface

# 1

# 2

AdminStatus enabled disabled

OperStatus enabled disabled

MTU

1500

1500

Forwarding enabled disabled

Framing ethernet ethernet

NetTools-> show IP ARP

# Interface

# 3

# 4

MediaType

3 (dynamic)

3 (dynamic)

PhysicalAddress

00:00:1d:04:40:5d

08:00:20:0e:d8:31

NetworkAddress

123.456.40.1

123.456.40.30

174246

6-64 8H02-16 User’s Guide

traceroute:

Syntax:

Description:

Options:

Example:

Network Tools traceroute [IP address]

The traceroute command generates a

TRACEROUTE request to a specified IP address and provides a display of all next-hop routers in the path to the device. If the device is not reached, the command displays all next-hop routers to the point of failure.

Not Applicable

NetTools-> traceroute 122.144.11.52

# next-hop[0] : 122.144.60.45

# next-hop[1] : 122.144.8.113

# next-hop[2] : 122.144.61.45

# 122.144.11.52 is alive : 3 hops away.

051477

8H02-16 User’s Guide 6-65

Chapter 6: Local Management

6.21.2

Special Commands

done, quit, exit:

Syntax:

Description:

Options:

Example: done

The done command enables the user to exit from Network Tools and return to the Main

Menu screen.

Not Applicable

NetTools-> done

Connection closed

051472

6-66 8H02-16 User’s Guide

APPENDIX A

SPECIFICATIONS

This appendix provides operating specifications for the Cabletron

Systems 8H02-16. Cabletron Systems reserves the right to change these specifications at any time without notice.

A.1

DEVICE SPECIFICATIONS

Processor:

Dynamic Random Access

Memory (DRAM):

FLASH Memory:

Intel i960 RISC processor control

4 MB upgradable to 8 MB

2 MB

A.2

PHYSICAL PROPERTIES

Dimensions:

Weight (Unit):

MTBF (Predicted):

7.1H x 43.2W x 34.3D (cm)

2.8H x 17W x 13.5D (in)

4.1 kg (9 lb)

200,000 hours

A.3

ELECTRICAL SPECIFICATIONS

Line Input Range

Volts (V)

100–125 Vac

200–250 Vac

Input Current

Amperes (A)

1.0 A

0.5 A

Frequency

Hertz (Hz)

50/60 Hz

Input Power

Volt Amps (VA)

100 VA

A.4

ENVIRONMENTAL REQUIREMENTS

Operating Temperature:

Storage Temperature:

Operating Humidity:

5

°

to 40

°

C (41

°

to 104

°

F)

-30

°

to 90

°

C (-22

°

to 194

°

F)

5% to 95% (non-condensing)

8H02-16 User’s Guide A-1

Appendix A: Specifications

A.5

INPUT/OUTPUT PORTS

Ports 1 through 14

Slots for optional ports 15 and 16

Ethernet (10BASE-T compliant) with

RJ45 type connectors.

Slots accept two types of optional Fast

Ethernet Interface Modules: the FE100-TX and the FE100-FX.

A.6

COM PORT/PIN ASSIGNMENTS

COM port Serial communications port that supports Local Management or connection to a UPS. Also supports

SLIP and PPP for the 8H02-16 management purposes.

The COM port has the following pin assignments:

Pin

6

7

4

5

8

1

2

3

Table A-1 COM Port Pin Assignments

Signal Name

Transmit Data (XMT)

Data Carrier Detect (DCD)

Data Set Ready (DSR)

Receive Data (RCV)

Signal Ground (GND)

Data Terminal Ready (DTR)

Request to Send (RTS)

Clear to Send (CTS)

Input/Output

Output

Output

Input

Input

NA

Output

Input

NA

A-2 8H02-16 User’s Guide

Agency Approvals

A.7

AGENCY APPROVALS

Safety

The 8H02-16 meets the safety requirements of UL 1950, CSA C22.2

No. 950, EN 60950 and IEC 950.

Immunity

The 8H02-16 meets the immunity requirements of EN 50082-1 including:

IEC 801-2 (ESD), IEC 801-3 (Radiated Susceptibility), and IEC 801-4

(EFT/B).

Emission

The 8H02-16 meets the emission requirements of FCC Part 15 Class A,

EN 55022 Class A and VCCI Class 1.

8H02-16 User’s Guide A-3

Appendix A: Specifications

A-4 8H02-16 User’s Guide

APPENDIX B

FE-100TX AND FE-100FX SPECIFICATIONS

The 8H02-16 supports two Fast Ethernet Interface Modules:

• FE-100TX

• FE-100FX

This appendix provides the specifications for these modules.

B.1

FE-100TX

The FE-100TX uses an RJ45 connector supporting Unshielded Twisted

Pair (UTP) cabling.

The slide switch on the FE-100TX determines the crossover status of the cable pairs. If the switch is on the X side, the pairs are internally crossed over. If the switch is on the = side, the pairs are not internally crossed

over. Figure B-1 shows the pinouts for the FE-100TX in both positions.

Position =

(not crossed over)

1. TX+

2. TX-

3. RX+

4. NC

5. NC

6. RX-

7. NC

8. NC

= x

FE-100TX

10

100

Position X

(crossed over)

1. RX+

2. RX-

3. TX+

4. NC

5. NC

6. TX-

7. NC

8. NC

166505

Figure B-1 FE-100TX Pinouts

8H02-16 User’s Guide B-1

Appendix B: FE-100TX and FE-100FX Specifications

B.2

FE-100FX

The FE-100FX shown in Figure B-2 uses an SC style connector that

supports multimode fiber optic cabling. Specifications for the FE-100FX are listed below.

Cable Type

50/125 µ m fiber

62.5/125

µ m fiber

100/140

µ m fiber

FE-100

FX

16

15

174240

Figure B-2 FE-100FX

Table B-1 Transmitter Power

Worst Case Budget

6.0 dB

9.0 dB

15.0 dB

Typical Budget

9.0 dB

12.0 dB

18.0 dB

The transmitter power levels and receive sensitivity levels listed are peak power levels after optical overshoot. A peak power meter must be used to correctly compare the values given above to those measured on any particular port. If power levels are being measured with an average power meter, add 3 dB to the measurement to compare the measured values to the values listed above.

B-2 8H02-16 User’s Guide

APPENDIX C

OPTIONAL INSTALLATIONS AND

MODE SWITCH BANK SETTINGS

ONLY QUALIFIED SERVICE PERSONNEL SHOULD

ATTEMPT THE FOLLOWING PROCEDURES.

NUR QUALIFIEZIERTE SERVICE PERSONNAL DIE

FOLGENDE PROCEDURE FOLGEN SOLLTEN.

SOLAMENTE PERSONAL CALIFICADO DEBE INTENTAR

ESTE PROCEDIMIENTO.

The top cover must be removed to gain access to the mode bank switches and to install the Fast Ethernet Interface Modules.

This appendix covers the following items:

Required tools (Section C.1)

Removing the chassis cover (Section C.2)

Locations, functions, and settings for the mode switches (Section C.3)

Installing Optional Fast Ethernet Interface Modules (Section C.4)

C.1

REQUIRED TOOLS

You need the following tools to perform the procedures covered in this appendix:

• Antistatic wrist strap

• Phillips screwdriver

8H02-16 User’s Guide C-1

Appendix C: Optional Installations and Mode Switch Bank Settings

C.2

REMOVING THE CHASSIS COVER

This section describes how to remove the 8H02-16 chassis cover.

DO NOT REMOVE THE COVER FROM THE 8H02-16 WHILE

POWER IS APPLIED TO THE UNIT. HAZARDOUS

VOLTAGES ARE PRESENT AND COULD CAUSE

PERSONAL INJURY AND/OR DAMAGE THE UNIT.

DO NOT POWER UP THE 8H02-16 AGAIN UNTIL THE

COVER AND SCREWS ARE IN PLACE.

DECKEL VON DAS 8H02-16 NICHT ABZIEHEN UNTER

SPANNUNG. GEFAHR FÜR DAS PERSONNAL UND/ODER

DAS GERÄT WEGEN GEFÄHRLICHE SPANNUNGEN

ENSTEHT.

8H02-16 NICHEINSCHALTEN SO LANG DER DECKEL UND

SCHRAUBEN NICHT EINGEBAUT SIND.

NO DEBE DE REMOVER LA TAPA DURENTE QUE ESTE

CONELTADO A LA CORRIENTE, UNA DESCARGA

ELECTRICA LE PUEDE CAUSAR Y PROBOCARLE DA ÑOS,

AL IGUAL QUE AL APARATO.

NO ENCHUFE A LA CORRIENTE HASTA QUE LA TAPA Y

LOS TORNILLOS ESTEN EN SU LUGAR.

To remove the chassis cover, proceed as follows:

1. Disconnect the 8H02-16 from the network as follows: a.

Unplug the power cord from the rear of the 8H02-16 chassis.

TURN OFF THE 8H02-16 BY UNPLUGGING THE POWER

CORD FROM THE REAR OF THE CHASSIS.

AM HINTEN DES 8H02-16 STECHEI ABZIEHEN UM AUS ZU

SCHALTEN.

APAGUE EL 8H02-16 DESENCHUFE EL CABLE DE LA

UNIDAD.

C-2 8H02-16 User’s Guide

Removing the Chassis Cover

TIP

Before performing step b, mark the cables connected to the

8H02-16 according to their associated port numbers. This is recommended for ease of reinstallation.

b. Disconnect all network cables attached to the 8H02-16.

2. If the 8H02-16 is rack mounted, remove it from the rack and remove

the rackmount brackets (refer to Chapter 3, Installation).

3. Use a Phillips screwdriver to remove the screws attaching the cover to

the 8H02-16 chassis. (See Figure C-1.)

4. Remove the cover by sliding it back until it clears the front of the chassis and then lifting it straight up and off of the chassis.

To reinstall the chassis cover, perform the removal procedures in reverse.

Chassis Cover

Chassis

Cover Screws (7)

1742-30

Figure C-1 Removing the Chassis Cover

8H02-16 User’s Guide C-3

Appendix C: Optional Installations and Mode Switch Bank Settings

C.3

SETTING THE MODE SWITCH

These switches are set at the factory and do not need to be changed unless you intend to perform the following:

• Force download a new image file from a BootP server.

• Clear the NVRAM and restore all user-entered parameters such as the

IP address and Community Names to the 8H02-16 “Default” configuration settings.

• Clear user-entered passwords stored in NVRAM and restore the default passwords.

Figure C-2 shows the location of the mode switches and the switch

settings for normal operation.

8H02-16 TOP VIEW WITHOUT COVER

FLASH

DRAM

MODE SWITCH BANK

8 7 6 5 4 3 2 1

OFF

ON

Forced Download Switch (This switch forces image file downloads.) stored in NVRAM.)

FRONT PANEL

Fast Ethernet

Interface Modules

Figure C-2 8H02-16 Mode Switch Location/Component Layout

1742-05

Switch definitions and positions are as follows:

• Switches 1 through 4 – For Cabletron Systems use only.

• Switch 5 – Autobaud Enable. The default (OFF) position enables

Autobaud sensing on the COM port for Local Management sessions.

Changing the switch to the ON position disables Autobaud sensing and sets the COM port to 9600 baud for Local Management sessions.

C-4 8H02-16 User’s Guide

NOTE

Setting the Mode Switch

• Switch 6 - Forced Download. Changing the position of this switch

(i.e., moving the switch from one position to the other) clears download information from NVRAM and forces the 8H02-16 to download a new image file from a BootP server.

After changing the position of switch 6, DO NOT reapply power to the 8H02-16 until there is a station acting as a BootP server, which contains the image file.

After changing the position of switch 6 and restarting the 8H02-16, the

8H02-16 requests a new image download until it either receives a new image or the RESET button on the front panel is pressed. When the

RESET button is pressed, the 8H02-16 continues trying to contact a

BootP server, but will time out in approximately one minute. If the

8H02-16 times out, the image is downloaded from its FLASH memory.

• Switch 7 - Clear NVRAM. Changing the position of this switch resets

NVRAM on either the next power up or the next operation of the front panel RESET switch. All user-entered parameters such as the IP address and Community Names are replaced with the 8H02-16

“Default” configuration settings.

• Switch 8 - Password Defaults. Changing the position of this switch clears user-entered passwords stored in NVRAM, and restores the default passwords. Once the 8H02-16 is reset, the passwords can either be reentered or the default passwords (Public and ENTER or

RETURN) may be used.

NOTE

Do not change the position of switch 8 unless it is necessary to reset the 8H02-16 Super-User configured passwords to their factory default settings.

8H02-16 User’s Guide C-5

Appendix C: Optional Installations and Mode Switch Bank Settings

C.4

INSTALLING OPTIONAL FAST ETHERNET

INTERFACE MODULES

Figure C-3 shows the location of the Fast Ethernet Interface Module

connectors on the 8H02-16 board for port slots 15 and 16.

8H02-16 TOP VIEW WITHOUT COVER

Connectors

FRONT PANEL

Fast Ethernet

Interface Modules

Figure C-3 Fast Ethernet Interface Module Connector Location

1742-11

To install a Fast Ethernet Interface Module in port slot 15 or 16, proceed as follows:

!

C AUT IO N

The Fast Ethernet Interface Module and the 8H02-16 are sensitive to static discharges. Use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could damage the module or the 8H02-16.

1. Remove the chassis cover as described in Section C.2.

2. Remove the coverplate from the port slot where the Fast Ethernet

Interface Module will be installed.

C-6 8H02-16 User’s Guide

Installing Optional Fast Ethernet Interface Modules

TIP

When installing Fast Ethernet Interface Modules in both port slots 15 and 16, remove the coverplates from both slot openings. In the following instructions, the optional module is shown being installed in port slot 16.

To remove a coverplate, refer to Figure C-4 and proceed as follows:

a.

Remove the two screws fastening the coverplate to the standoffs.

Save the screws.

b. Lift and remove the coverplate from the top of the front standoffs.

Coverplate

FE-100TX

10

100

Rear

Standoff

Front

Standoffs

1742-38

Figure C-4 Coverplate Removal

3. Remove the screw from the rear standoff. Save the screw.

!

C AUT IO N

When installing an FE-100FX module into the 8H02-16, remove the rubber plug on the module before proceeding.

8H02-16 User’s Guide C-7

Appendix C: Optional Installations and Mode Switch Bank Settings

4. See Figure C-5. Gently pull the faceplate of the 8H02-16 forward to allow room for the Fast Ethernet Interface Modules to be aligned over the connector.

5. Carefully lower the Fast Ethernet Interface Module onto the standoffs while inserting the module connector into the associated motherboard connector.

Faceplate

FE-100TX

10

100

Module

Module

Connector

Standoff

Motherboard

Connector

Standoffs

15

16

1742-39

Figure C-5 Installing the Fast Ethernet Interface Module

6. Press down firmly on the Fast Ethernet Interface Module until the pins slide all the way into the motherboard connector. Ensure that the Fast

Ethernet Interface Module seats flush on the standoffs.

7. Secure the Fast Ethernet Interface Module with the screws saved in steps 2 and 3.

8. Installation is complete. Reinstall the chassis cover, reconnect all network cables and reconnect the power cord to the 8H02-16.

C-8 8H02-16 User’s Guide

Numerics

100BASE-FX

cable length 2-4

cable loss 2-3 fiber optic budget 2-3 propagation delay 2-3

100BASE-TX

cable length 2-2

propagation delay 2-3 temperature 2-3

10BASE-T

connection 3-7

impedance 2-2

length 2-1 requirements 2-1

temperature 2-2

A

Access policy 6-24

B

Baud rate 6-12, 6-22

Bridge address 6-28

Bridge Configuration screen 6-28 bridge address 6-28

MAC address 6-29

number of ports 6-28

port # 6-29

port status 6-30 selecting the STA 6-30

state 6-29 status 6-29 type of STA 6-29

Bridge Statistics screen 6-54

frames fltrd 6-55 frames frwded 6-55

frames rcvd 6-54 frames txmtd 6-54 interface # 6-54

INDEX

C

Cable specifications

100BASE-TX UTP 2-2

10BASE-T UTP 2-1

multimode fiber optic 2-3

COM port 6-18

pin assignments A-2

Command Set 6-58

Configuration

terminal 5-1

Connecting to the network 3-6

CPU management reservation 6-37,

6-38

Crossover switch B-1

Current switch utilization 6-37

D

Default gateway 6-11, 6-14

Default interface 6-11, 6-15

Device Configuration screen 6-8

Device date 6-11

Device Menu screen 6-6

Device Specific Configuration Menu screen 6-31

Device Statistics Menu screen 6-53 bridge statistics 6-53 port statistics 6-53

Document conventions 1-7

E

Environmental requirements A-1

8H02-16 User’s Guide Index-1

Index

F

FE-100FX

transmitter power B-2

Fiber connection

SC to SC 3-11

Full Duplex Configuration screen 6-33

full duplex 6-34 link status 6-34 operation mode 6-34, 6-35 port status 6-34 standard enet 6-34

G

General Configuration screen 6-10

application 6-12 baud rate 6-12, 6-22

COM port 6-18 to 6-21

default gateway 6-11, 6-14 default interface 6-11, 6-15 device date 6-11 device time 6-11, 6-16

IP address 6-10, 6-13

MAC address 6-10

screen lock-out time 6-12, 6-17

screen refresh time 6-11, 6-17 subnet mask 6-11, 6-13

H

Help 1-8

related manuals 1-9

High Speed Interface screen 6-39

advertised ability 6-41 configuring an FE-100FX 6-41

configuring an FE-100TX 6-42

current operational mode 6-40 desired operational mode 6-40 link status 6-40 port type 6-40

setting the FE-100FX 6-42 setting the FE-100TX 6-42

I

Installation

Fast Ethernet Interface Module C-6

IP address 6-10, 6-13

K

Keyboard conventions 6-2

L

LANVIEW LEDs 4-1

Local Management

features 1-6

Password screen 6-3

M

MIB Navigator 6-58

MIB Navigator Commands

arp 6-59

defroute 6-60, 6-61

done 6-66 exit 6-66

netstat 6-62

ping 6-63

quit 6-66

traceroute 6-65

N

Network connection

FE-100FX 3-10

FX-100TX 3-8

Index-2 8H02-16 User’s Guide

P

Password screen 6-3

Passwords 6-23

Peak switch utilization 6-37

Physical properties A-1

Port Redirect Function screen

destination port 6-51 source port 6-51 status 6-51

Port Statistics screen

admin status 6-57 application 6-57 broadcasts 6-57

bytes 6-56 collisions 6-56

CRC/alignment errors 6-56 fragments 6-56 frames 6-56 jabbers 6-56

link status 6-57 multicasts 6-57 operation mode 6-57

oversize packets 6-56 port # 6-56

port type 6-57

total errors 6-56 undersize packets 6-56

R

RESET button 4-6

Runtime IP address discovery 5-4

S

Safety A-3

Screen lock-out time 6-12, 6-17

Screen refresh time 6-17

Screens

Bridge Configuration screen 6-28

Bridge Statistics screen 6-54

Device Configuration screen 6-8

Device Menu screen 6-6

Index

Device Specific Configuration

Menu screen 6-31

Device Statistics Menu screen 6-53

Full Duplex Configuration screen 6-33

General Configuration screen 6-10

High Speed Interface screen 6-39

Password screen 6-3

Port Redirect Function screen 6-50

Port Statistics screen 6-55

SNMP Community Names screen 6-23

SNMP Traps screen 6-26

System Resources screen 6-36

SNMP Community Names screen 6-23

access policy 6-24 community name 6-24

SNMP Traps screen 6-26

enable traps 6-27

trap community name 6-26 trap destination 6-26

trap table configuration 6-27

Spanning Tree Algorithm 6-29

Specifications A-1

Standards compatibility 1-5

Subnet mask 6-11, 6-13

System Resources screen

CPU management

reservation 6-37, 6-38

CPU type 6-36

current switch utilization 6-37

DRAM installed 6-37

Flash memory installed 6-37

NVRAM installed 6-37 peak switch utilization 6-37 reset peak switch utilization 6-37

8H02-16 User’s Guide Index-3

Index

T

Terminal configuration 5-1

Trap table configuration 6-27

Traps

enable 6-27

Troubleshooting 4-1

checklist 4-5

U

Unpacking 3-1

V

VT setup 5-1

Index-4 8H02-16 User’s Guide

POWER SUPPLY CORD

The mains cord used with this equipment must be a 2 conductor plus ground type with minimum 0.75 mm square conductors and must incorporate a standard IEC appliance coupler on one end and a mains plug on the other end which is suitable for the use and application of the product and that is approved for use in the country of application.

GERMAN:

Die Netzleitung, die mit diesem Geraet benuetzt wird, soll einen zwei Leiter mit

Erdleiter haben, wobei die Leiter mindestens 0.75 mm sind, mit einer normalen

IEC Geraetesteckdose an einem Ende und einem Geraetestecker am anderen Ende versehen sind, der fuer den Gebrauch und die Anwendung des Geraetes geeignet und der zum Benuetzen im Lande der Anwendung anerkannt ist.

SPANISH:

El cable principal de la red eléctrica utilizado con este equipo debe tener 2 conductores y 1 toma de tierra con un mínimo de 0.75 mm2 cada uno y necesita tener un aparato de acoplamiento standard IEC en un extremo y un enchufe para el cable principal de la red eléctrica en el otro extremo, lo cual sea adecuado para el uso y applicación del producto y lo cual sea aprobado para uso en el pais de applicación.

FRENCH:

Le cordon d' alimentation reliant cet appareil au secteur doit obligatoirement avoir deux fils conducteurs de 0.75 mm2 minimum et un fil de terre. It doit également

être équipé du côté appareil d'une fiche agrée IEC et du côte secteur, d'une prise adaptée à l'usage du produit et aux normes du pays où l'appareil est utilisé.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents