Infiray AT1280 Online Thermal Camera User Manual

Add to My manuals
26 Pages

advertisement

Infiray AT1280 Online Thermal Camera User Manual | Manualzz
AT1280
Online Temperature
Measurement Thermal Camera
User Manual V1.0.4
IRay Technology Co., Ltd.
www.infiray.com
Introduction to IRay Technology
IRay Technology Co., Ltd. concentrates on developing infrared thermal imaging technologies and
manufacturing relevant products, with completely independent intellectual property rights. IRay is
committed to providing global customers with professional and competitive infrared thermal imaging
products and solutions. The main products include IRFPA detectors, thermal imaging modules, and
terminal thermal imaging products.
With R&D personnel accounts for 48% of all employees, 787 intellectual property projects in terms of IRay
have been authorized and accepted: 629 patented technologies authorized and accepted in China
(including those for integrated circuit chips, MEMS sensors design and manufacture, Matrix III image
algorithms and intelligent precise temperature measurement algorithms, etc.); 18 patented technologies
authorized and accepted overseas; 101 software copyrights; and 39 integrated circuit layout designs.(Up
to August, 2021)
IRay products have been applied in various fields, including epidemic prevention and control, industrial
thermography, security and fire control, night vision observation, automatic driving, Internet of Things, AI,
and machine vision.
AT1280 Online Temperature Measurement Thermal Camera User Manual
Table of Contents
1. Legal Disclaimer .......................................................................................................................................1
1.1 Legal Disclaimer ............................................................................................................................... 1
1.2 Copyright ...........................................................................................................................................1
1.3 Quality Assurance .............................................................................................................................1
2. Safety Information ....................................................................................................................................2
3. Notice to user ........................................................................................................................................... 3
3.1 Calibration .........................................................................................................................................3
3.2 Accuracy ........................................................................................................................................... 3
3.3 Video Teaching ................................................................................................................................. 3
3.4 Documentation Updates ................................................................................................................... 3
4. Customer Help ..........................................................................................................................................3
4.1 FAQ ................................................................................................................................................... 3
4.2 Download .......................................................................................................................................... 3
5. Product Introduction ............................................................................................................................... 4
6. Product Figure and Explanation ............................................................................................................ 5
7. Product Models Reference ..................................................................................................................... 6
8. Lens Parameters ...................................................................................................................................... 8
9. Quick Start Guide .....................................................................................................................................9
10. Product and Accessories List ............................................................................................................ 10
11. Mechanical Installation ........................................................................................................................11
11.1 Camera Mounting ......................................................................................................................... 12
11.1.1 Illustrations ..........................................................................................................................12
11.1.2 Explanations ....................................................................................................................... 12
12. Technical Data ...................................................................................................................................... 14
12.1 AT1280 .......................................................................................................................................... 14
13. Mechanical Drawings .......................................................................................................................... 17
14. Common Troubleshooting .................................................................................................................. 18
15. Cleaning Thermal Camera .................................................................................................................. 19
15.1 Cleaning Camera Housing, Cables and Other Items .................................................................. 19
15.2 Cleaning Infrared Lens ................................................................................................................. 20
16. Terms and Definitions ......................................................................................................................... 21
Appendix A Emissivity of Common Materials ........................................................................................ 22
AT1280 Online Temperature Measurement Thermal Camera User Manual
1. Legal Disclaimer
1.1 Legal Disclaimer
The thermal cameras manufactured by IRAY TECHNOLOGY are warranted for a period of two-year and
the accessories are warranted for a period of three-month form the delivery date of the original purchase,
provided such products have been under normal storage, use and maintenance.
This warranty extends only to the original purchaser and is not transferable. It is not applicable to any
product which has be subjected to misuse, neglect, accident or abnormal conditions of operation.
In the case of a defect in a product covered by this warranty the product must not be further used or
maintained in order to prevent additional damage. The purchaser shall promptly report any defect to IRAY
TECHNOLOGY or this warranty will not apply.
IRAY TECHNOLOGY will, at its option, repair or replace any such defective product free of charge if, upon
inspection, the product or accessories prove to be defective, the user can contact with after-sales service
department of IRAY TECHNOLOGY within the said warranty period.
1.2 Copyright
©IRay Technology Co., Ltd. 2020. All rights reserved worldwide. All contents in this manual, including
words, pictures, images, etc., belong to IRAY TECHNOLOGY CO., LTD. (Hereinafter referred to as “THE
COMPANY” or “IRAY TECHNOLOGY”). No part of the manual, in whole or part, may be copied,
photocopied, translated, or transmitted without the prior written permission of IRAY TECHNOLOGY.
This manual is used as a guide. The photos, graphics, diagrams and illustrations provided in the manual
are only used to explain, which may be different from the specific product. The real product shall prevail.
We try our best to make sure the contents in this manual are accurate. We do not provide any
representations or warranties in this manual.
IRAY TECHNOLOGY reserve the right to update the manual. If you need the latest version of this manual,
please contact us. It is recommended that you use this manual with the guidance of professionals.
1.3 Quality Assurance
The Quality Management System under which these products are developed and manufactured has been
certified in accordance with the ISO9001 standard.
We reserve the right to make changes and improvements on any of the products without prior notice.
1
AT1280 Online Temperature Measurement Thermal Camera User Manual
2.Safety Information
WARNING
1.Make sure you read all applicable Material Safety Data Sheets (SDS) and warning
labels on containers before you use a liquid. The liquids can be dangerous. Injury to
persons can occur.
2.It is prohibited to use the product in a high temperature above 85 °C or in a low
temperature below-45 °C.
3.It is forbidden to disassemble or refit the thermal camera at will.
CAUTION
1.No matter there is a lens cover or not, do not point the infrared thermal camera
towards strong light or equipment with laser radiation. This will affect the accuracy of
the thermal camera and even damage the detector in the thermal camera.
2.Do not use the product under conditions that doesn’t match the environmental
requirements. For specific use environment requirements, see the product parameter
table.
3.Do not apply solvents or equivalent liquids to the camera, the cables, or other
items.
4.Be careful when you clean the infrared lenses. The lens has an anti-reflective
coating which is easily damaged. Damage to the infrared lens can occur with too
much force or cleaning with rough objects such as tissues.
2
AT1280 Online Temperature Measurement Thermal Camera User Manual
3.Notice to user
3.1 Calibration
IRAY TECHNOLOGY recommends that you verify your calibration yearly in order to ensure accuracy. You
can verify the calibration through IRAY TECHNOLOGY or third-party organizations.
3.2 Accuracy
For very accurate results, we recommended that you wait 30 minutes after you have started the camera
before measuring a temperature.
3.3 Video Teaching
You can search for mount and use videos from our website.
3.4 Documentation Updates
Our manuals are updated several times per year, and we also issue product-critical notifications of
changes on a regular basis. Please visit our website to access the latest manuals and notifications.
4.Customer Help
4.1 FAQ
You can find answers to FAQ about this model on the service support page of our official website.
4.2 Download
You can download the following contents from our website: www.infiray.com
Product Documentation
Client Software
Video Teaching Courses
3
AT1280 Online Temperature Measurement Thermal Camera User Manual
5.Product Introduction
Compact
Support PoE
Main Features
The second generation auto-focus algorithm
Simultaneous output of temperature data and image data
Infrared detector of MP array
Several optional lenses
Power detection
Industrial detection
Process Control
Typical Applications
Machine vision scientific research
Quality Inspection
Status Monitoring
Fire Warning
4
AT1280 Online Temperature Measurement Thermal Camera User Manual
6.Product Figure and Explanation
6
No.
Explanation
1
Infrared lens
2
Power interface
3
LED light
4
Ethernet/Network cable interface
5
Tripod connection
6
Accessories from left to right:
Power adapter, gigabit network cable, power cable
Table 6.1 Explanation of Product Appearance
5
AT1280 Online Temperature Measurement Thermal Camera User Manual
7.Product Application Scenarios
No.
Descriptions
1
PC/Display
2
Exchanger
3
Thermal camera
4
The detected object
5.6.7
Cables
6
AT1280 Online Temperature Measurement Thermal Camera User Manual
8. Product Models Reference
AT1280
4
X
Model
Lens
Reserved
AT1280
4: 19mm
X
AT1280
5: 35mm
X
Table 8.1 Product Models List
You can refer to the below table for the detailed description of the reserved position.
D/F
Chinese/English
S/N
Standard/no logo
P
P:support GigE Vision protocols
X
Reserved for the customized product
Table 8.2 Detailed Info for the Reserved Position
For example: AT12804DSPX stands for AT1280 with 19mm lens, Chinese, standard.
7
AT1280 Online Temperature Measurement Thermal Camera User Manual
9.Lens Parameters
Resolution
Focal Length
FOV(H×V)
IFOV
1280×1024
19mm
44°×35.8°
0.63mrad
1280×1024
35mm
25.1°×20.1°
0.34mrad
Table 9.1 AT1280 Lens Parameters
8
AT1280 Online Temperature Measurement Thermal Camera User Manual
10.Quick Start Guide
Please follow the steps:
1.
Install IRT_TAS_AT, the software may be updated, the actual version shall prevail.
The computer configuration for installing the software is recommended to meet the
following conditions:
1.) i5-9500T and above CPU
2. )8G and above memory
3. )64-bit Win10 system
4.) Main board H370 chip set
5.) Support Gigabit network.
6. )The screen resolution is recommended to be 1920×1080
7.) Video Memory 128MB
8.) Network card RTL8168/8111/8112 Gigabit Ethernet Controller
2.
Follow the installation instructions in Chapter 11.1.2 to connect the thermal
camera, power supply, and a computer. You can also connect to the Ethernet cable
through the PoE power supply module.
3.
Follow the instructions in IRT_TAS_AT_User Manual to set the computer IP,
change the IP to 192.168.1. × × × .(Do not choose 123 or 29 to avoid connection
failure for the same IP with the camera).
4.
Run IRS_TAS_AT as an administrator, enter the correct user name and password,
and click Login.
5.
Continue to follow the procedures in the software instructions. If the camera is
successfully connected and the image is normal, then the software can be used for
thermal imaging control and temperature analysis.
6. The client software TAS is applicable for the thermal camera, which can realize
other functions needed.
The client software TAS can realize the below functions:

Image capture and video recording

Thermographic analysis/secondary analysis

Export recorded infrared data

Set the parameters and alarm information

Update firmware to acquire the new functions
9
AT1280 Online Temperature Measurement Thermal Camera User Manual
11.Product and Accessories List
Product and Accessories
AT online temperature measuring thermal camera
Network cable
Power cable
Power adapter
Table 11.1 Product and Accessories List
10
AT1280 Online Temperature Measurement Thermal Camera User Manual
12.Mechanical Installation
The thermal camera can be mounted to the desired position through the mounting hole at the bottom.
WARNING
Do not use too long screws. That will damage the thermal camera.
The temperature rise will occur during normal operation. If the thermal camera is
used under poor heat
dissipation conditions, the temperature rise may be too high, which will affect the temperature
measurement performance. In order to ensure the normal use of the thermal camera, it is recommended
to be used under good heat dissipation conditions.
11
AT1280 Online Temperature Measurement Thermal Camera User Manual
12.1 Camera Mounting
12.1.1 Illustrations
Connecting Camera
Interface 1
Interface 2
12.1.2 Explanations
1.Fix the thermal camera at the desired location according to the specific use method. The recommended
location is in a sheltered area with a relatively stable thermal state.
2.Connect the power cable to the power adapter and interface 1 respectively, power on the thermal
camera, and connect the two ends of the network cable to interface 2 and the PC Gigabit Ethernet port
respectively.
3.Wait 30 minutes after you have stated the camera, then the temperature can be measured and
analyzed by the client software of the computer.
12.1.3 Cable strain relief
In installations where the camera is subject to vibrations or shocks the power cord may need an external
strain relief arrangement to avoid power port failure.
The following pictures show two examples on how cable strain relief of the power cord can be solved.
12
AT1280 Online Temperature Measurement Thermal Camera User Manual
Example 1 Cable strain relief with zip ties
Example 2 cable strain relief with cable clamps
13
AT1280 Online Temperature Measurement Thermal Camera User Manual
13.Technical Data
13.1 AT1280
Imaging and Optical Data
Resolution
1280×1024
Thermal Sensitivity/NETD
≤50mK @25℃, F#1.0
Image Frequency
15Hz
Focus
Support Auto-focus
Detector Data
Detector Type
VOx, Uncooled FPA detector
Spectral Range
8~14μm
Pixel
12μm
Temperature Measurement
Object Temperature Range
Accuracy
-20℃~150℃
0℃~550℃
±2℃ or ±2%
Any fixed point
Full screen max./min. temperature capture
Measurement Tools
Center spot
Line/Area analysis tool
Manually choose temperature width
14
AT1280 Online Temperature Measurement Thermal Camera User Manual
Ethernet
Ethernet
Control and imaging
Ethernet Type
Gigabit
Ethernet Standard
IEEE 802.3
Ethernet Connector Type
RJ45
Ethernet Image Stream
GigE Vision
Ethernet Power Supply
PoE power supply supported
Ethernet Protocol
TCP,UDP,ICMP,DHCP
Image Adjustment
Brightness and Contrast Adjustment
Manual / Auto 0(defaulted) / Auto 1
Polarity
Black hot/white hot
Palette
18 palettes are available
Image Flip
Left and right / up and down / diagonal
ROI
Support
Environmental Data
Operating Temperature Range
-20℃~60℃
Storage Temperature Range
-40℃~85℃
Humidity (operating & storage)
5%~75%RH(no condensation)
EMC
With EMC design
Shock
30g,11ms, all axial
Vibration
4.3g, random vibration, all axial
15
AT1280 Online Temperature Measurement Thermal Camera User Manual
Power System
Typical power consumption@25℃
≤4.5W
Connector type for external power supply
DC
Voltage
6-16VDC
Physical Data
Weight
725g
Thermal Camera(L×W×H)
70mm×63mm × 143mm
Housing Material
Aluminum
Shipping Information
Packing Type
Carton
Weight with Package
1.6kgs
Packaging Size
233mm×228mm×154mm
Thermal camera
List of Contents
Power adapter
Power cable
Gigabit cable
Country of Origin
China
Table 13.1.1 AT1280 Performance Parameters
16
AT1280 Online Temperature Measurement Thermal Camera User Manual
14.Mechanical Drawings
17
AT1280 Online Temperature Measurement Thermal Camera User Manual
15.Common Troubleshooting
Troubles
Possible Cause
Images are blurred
Objective lens focal
length does not match
Solutions
Click auto focus in the software
after aiming the thermal camera
at the target
No image calibration
Click the shutter correction button
for a long time
in the software
The supply voltage
exceeds the normal
working supply voltage
range
Camera can’t be
started
The power connector
is loose
The stabilization time
for thermal camera is
Inaccurate
temperature
too short.
measurement
Focus is not good.
The client cannot
open, the error
VC environment is not
shows no mfc300.dll
installed
Check whether the power supply
voltage is between 6 and 16V
Check whether the power cable is
connected
Keep the thermal camera stable
for more than 10 minutes.
Align the target for automatic
focus calibration.
Install Microsoft Visual Studio
Network parameters
can be recognized,
Network IP address
Change the network configuration
but can’t be
setting is not correct.
back to automatic acquisition.
Power cable or
After checking the power supply
Image is stuck.
network cable
connection is loose.
and network cable connection,
restart the software.
Video is not
Jumbo frame is not
Check the computer configuration
continuous.
opened
again.
connected.
Table 15.1 Product Common Troubleshooting
18
AT1280 Online Temperature Measurement Thermal Camera User Manual
16.Cleaning Thermal Camera
16.1 Cleaning Camera Housing, Cables and Other Items
Camera Housing, Cables and Other Items
One of the following liquids can be used.
Liquids
1.Warm water
2.A Weak detergent solution
Cleaning Tools
A soft cloth
Please follow this procedure:
Cleaning Procedure
1.Soak a soft cloth in the liquid.
2.Twist the cloth to remove excess liquid.
3.Clean the camera parts with the cloth.
19
AT1280 Online Temperature Measurement Thermal Camera User Manual
16.2 Cleaning Infrared Lens
Cleaning Infrared Lens
One of the following liquids can be used.
Liquids
1. Commercial lens cleaning liquid with more than
30% is opropyl alcohol.
2. 96% ethyl alcohol(C2H5OH).
Cleaning Tools
Dustless cloth, cotton wool
Please follow this procedure (Take dustless cloth as
Cleaning Procedure
an example).
1.Soak the dustless cloth in the liquid.
2.Gently wipe the lens with the dustless cloth
CAUTION
The dustless cloth or cotton wool should be used one time only.
20
AT1280 Online Temperature Measurement Thermal Camera User Manual
17.Terms and Definitions
Terms
FPA
(Focal Plane Array)
Definition
A type of infrared detector
IFOV
A resolution measure method of infrared thermal
(Instantaneous Field of View)
camera (that is, the field of view of a pixel)
FOV
(Field of View)
NETD
(Noise Equivalent
Temperature Difference)
The angle of view that the infrared camera can see
HFOV is the horizontal angle of FOV,VFOV
is the vertical angle of FOV.
A measure of image anti-interference level
of infrared thermal camera.
21
AT1280 Online Temperature Measurement Thermal Camera User Manual
Appendix A Emissivity of Common Materials
Material
Temperature(℃)
Emissivity
Water
0~100
0.95~0.98
Soil(dry)
20
0.92
Soil(wet)
20
0.95
Woods
17
0.962
Sand
20
0.9
Sandstone
19
0.909~0.935
PVC plastic
70
0.93
Asphalt
20
0.967
Paint
70
0.92~0.94
Wallpaper
20
0.85~0.90
Cloth
20
0.98
Concrete
20
0.92
Pavement surface
5
0.974
Smooth porcelain
20
0.92
Ceramic tile
17
0.94
Gypsum
17
0.86
Bricks
35
0.94
Hard rubber
0~100
0.89
Charcoal
20~400
0.95~0.97
Granite(rough)
20
0.879
Cold rolled steel
70
0.09
Oxidized steel
50
0.88
Copper
20
0.07
Oxidized copper
50
0.6~0.7
22
AT1280 Online Temperature Measurement Thermal Camera User Manual