48/50HG-1SB
48HGD/F014-028
50HG014-028
SINGLE-PACKAGE COOLING UNITS WITH
FACTORY-INSTALLED GAS HEAT AND
SINGLE-PACKAGE COOLING UNITS WITH
OPTIONAL ELECTRIC HEAT
—
—
—
PERFORMANCE DATA
CERTIFIED DIMENSION PRINT
ROOF CURB DIMENSION PRINT
© Copyright 2000 Carrier Corporation • Syracuse, New York 13221
Form 48/50HG-1SB Supersedes 48HG-1SB
Printed in U.S.A.
10-00
Catalog No. 514-851
Date:
48/50HG014-028
SINGLE-PACKAGE COOLING UNIT
WITH OPTIONAL ELECTRIC HEAT AND
COOLING UNIT WITH GAS HEAT
Supersedes:
JOB NAME:
LOCATION:
BUYER:
BUYER P.O. #
UNIT NUMBER:
MODEL NUMBER:
PERFORMANCE DATA CERTIFIED BY:
48/50HG
Rev.:
CARRIER #
DATE:
DESCRIPTION
ARI STANDARD
360
The 48HG units are one-piece electric cooling/gas heating units, prewired and
precharged. The 50HG units are one-piece electric cooling/electric heating units,
prewired and precharged. The 48/50HG units have bottom air openings for separate
supply and return ductwork. The 48HGD units are low heat units and the 48HGF
units are high heat units. The 50HG units are available with 3 sizes of electric heat or
as cooling only units. All units are intended for installation on an accessory curb
(ordered separately). Bottom discharge on concentric applications requires a transition duct (field-supplied) external to the unit.
FEATURES
Standard one-year warranty.
Five-year warranty on the compressor (48/50HG014-020,028). Oneyear warranty on the compressor (48/50HG024).
Units are rated in accordance with ARI standard 360. Standard unit is
certified and listed by UL and UL, Canada.
Low outdoor temperature cooling operation to 40 F (4 C) as standard.
Freeze protection is provided as standard via ComfortLink™ control.
Multiple scroll compressors with internal linebreak overload
protection.
Indoor and outdoor coils constructed of aluminum fins mechanically
bonded to seamless internally grooved copper tubes.
Multiple thermostatic expansion valve (TXV) metering devices.
Filter drier is provided in each refrigeration circuit.
Gear-driven economizer with spring-return motor.
Automatic changeover (when used with an auto-changeover
thermostat).
Single-point gas (48HG) and electric connections. Disconnect in
accordance with NEC must be field-supplied and installed.
All units utilize multi-stage cooling.
Belt drive adjustable evaporator fan.
Slide-out indoor fan motor assembly.
Cabinet of galvanized steel, bonderized and finished with prepainted
baked enamel.
Two-inch disposable type return air filters factory installed.
Multiple direct-drive propeller condenser fans with vertical discharge.
Five-year non-prorated warranty on Alumagard™ coated TurboTubular™ heat exchanger. (48HG)
2-stage gas heat in a single 2-stage gas valve. (48HG)
2-stage electric heat. (50HG)
Induced draft combustion system with Hall Effect sensor to detect
proper operation of induced-draft motor. (48HG)
Heavy Alumagard coated heat exchangers with aluminized steel
burners. (48HG)
Heating controls with solid-state direct spark ignition system (pilotless
system) and redundant gas valve. High temperature limit switches and
auto. reset flame rollout switch standard. (48HG)
Integrated gas control board with built-in diagnostics to determine
error codes and control fan on/off delays for energy savings and maximum comfort control. (48HG)
Integrated gas control board provides anti-cycle protection for gas
heat operation. (48HG)
Field-convertible horizontal supply.
PERFORMANCE DATA
2
Unit Operating Weight __________________________________
Curb Weight __________________________________________
COOLING
Gross Total Capacity ___________________________________
@ Condenser Air Temperature _________________________
Gross Sensible Capacity ________________________________
Compressor Power Input ________________________________
Indoor Entering db _____________
wb ________________
Airflow ___________ External Static Pressure _______________
Indoor Fan Motor Size __________________________________
Exhaust Fan Motor Size _________________________________
HEATING
Heating Capacity:
Stage 1 ______________________________________________
Stage 2 ______________________________________________
Heating Capacity Total __________________________________
Stage 1 ______________________________________________
Stage 2 ______________________________________________
Heating Capacity Total __________________________________
ELECTRICAL DATA
Power Supply to Unit ____________
Volts ______________
Phase ____________ Hz
Minimum Circuit Amps ______________ Maximum Overcurrent Protection _______________
SUBMITTAL DATA
Job Name __________________________________________________________
Architect ___________________________________________________________
Engineer ___________________________________________________________
Contractor __________________________________________________________
CUT ALONG DOTTED LINE
Unit Designation _____________________________________________________
OPTIONS AND ACCESSORIES
FACTORY-INSTALLED OPTIONS
Economizer
Additional 5-Year (6th-10th Year) Extended Protection Plan
on the Heat Exchanger
Four-Year Extended Protection Plan on the Compressor
(Size 024 Only)
Power Exhaust
Barometric Relief
Low and High Gas Heat (48HG only)
Low/Medium/High Electric Heat (50HG only)
CO Sensor
CO Sensor
Smoke Detector
Plugged Filter Indicator
Alternate High-Static Drive
Pre-Coated Condenser Coils
E-Coated Condenser Coils
E-Coated Evaporator and Condenser Coils
Copper Condenser Coil
CUT ALONG DOTTED LINE
2
Copper Condenser and Evaporator Coils
Copper Condenser Coil with E-Coat
Copper Condenser and Evaporator Coils with E-Coat
Non-Fused Disconnect
Convenience Outlet
FIELD-INSTALLED ACCESSORIES
Differential Enthalpy Control
Roof Curb (14 in.)
Roof Curb (24 in.)
Additional 5-Year (6th-10th Year) Extended Protection Plan
on the Heat Exchanger
Four-Year Extended Protection Plan on the Compressor
(Size 024 Only)
Power Exhaust
Barometric Relief
Thermostat and Subbase
T-55 Space Temperature Sensor
T-56 Space Temperature Sensor with Offset
3
4
CERTIFIED DIMENSION PRINT
5
CUT ALONG DOTTED LINE
CERTIFIED DIMENSION PRINT
CUT ALONG DOTTED LINE
6
6 1/8” (155)
1’-3” (381)
CRRFCURB011A00
CRRFCURB010A00
DESCRIPTION
ALL
UNIT
1’-4 5/16”
(415)
1’-0 7/16”
(316)
DEG.
.28
A
IN.
.45
DEG.
.28
DIMENSIONS* (degrees and inches)
B
IN.
.43
NOTE: To prevent the hazard of stagnant water build-up in the
drain pan of the indoor section, unit can only be pitched as shown.
4.
Direction of airflow.
5. Roof curb: 16 ga. (VA03-56) stl.
NOTES:
1. Roof curb accessory is shipped disassembled.
2. Insulated panels: 1 in. thick neoprene coated 11/2 lb density.
3. Dimensions in ( ) are in millimeters.
Standard Curb
14″ High
Standard Curb
for Units
Requiring High
Installation
1’-7 7/8” (505)
2′-0″
(610)
CURB
HEIGHT
1′-2″
(305)
EXISTING APPLICATIONS:
THIS AREA CLEAR FOR
POWER AND GAS ENTRY
PKG NO. REF.
3-IN. K.O.
7/8-IN. K.O.
2 1/8” (53)
ROOF CURB DIMENSION PRINT
48HGF016, 024
ROOF CURB (BOTTOM SUPPLY /RETURN UNITS)