INSTALLATION
RCI 0163 / 0163LM
SURFACE MOUNTED RIM STRIKE
Installations of this RIM strike qualify as “Indoor Use Only” when not continuously exposed to an outdoor environment.
Important: The 0163 Electric Strikes should never be used as a door stop.Please install stops on frame in appropriate locations.
Ensure the exit device functions as intended for life safety concerns by verifying electric strike and exit device compatibility.
Maximum latch projection is essential to obtain full holding force.
Since the RCI 0163 strike is fail secure the local Authority Having Jurisdiction shall be consulted with regard to the use of selected
panic hardware to ensure emergency exit from the secured area.
UL 294 Performance Ratings:
Catalog Specifications
MODE
Access Control Line Security : Level I
VOLTAGE
CURRENT
DUTY
AMPS
OHMS
Fail Secure
12V
AC
Intermittent
0.15
37
Fail Secure
12V
DC
Continuous
0.27
37
Standby Power : Level I
Fail Secure
24V
AC
Intermittent
0.33
37
Fail Secure
24V
DC
Continuous
0.14
148
Electrical Latch Monitor
Specification:
Fail Secure
11-16V
AC
Intermittent
0.13-0.19
37
Fail Secure = Fail Locked = FL AC = Alternating Current DC = Direct Current
Intermittent Duty = Energized less than 1 minute with 1:5 duty ratio
Continuous Duty = Energized 1 minute or more
Dimensional Details
IS0163
Destructive Attack : Level I
Endurance : Level IV
• 12VDC, 1A, resistive load
Note: Contacts identified on the harness
sleeve are indicated with the keeper in a
closed and locked condition, with no latch
present
© 2022 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]
PCN2208
R09-22GR
Instructions
1. Determine the horizontal centerline of the exit device latch and transfer centerline to the frame stop.
2. Position the template onto the frame aligning with centerline and against the closed door. Center-punch the two mounting holes
and the wire access hole as shown.
3. Drill and tap the two mounting holes and drill the wire access hole(s).
4. Test fit electric strike to ensure full latch engagement. Use provided 1/16" spacer to maximize latch contact.
5. Make wire connections from the power source to the wire harness supplied.
For 12VDC or 12-24VAC or 11-16VAC input power: - connect RED and BLUE wires to positive (+),
- connect BLACK and YELLOW wires to negative (-).
For 24VDC input power only: - connect YELLOW and BLUE wires together
- connect RED wire to positive (+)
- connect BLACK wire to negative (-).
If using AC power, polarity is not observed.
To meet BHMA A156.31, install the MOV provided across the positive and negative wires or terminals of the harness.
The MOV is not polarity sensitive.
NOTE: Overheated or burnt coils caused by incorrect input voltage / wire harness combinations will not be covered under warranty
6. Connect monitor wires of LM model.
7. Mount the electric strike with 1/4-20 UNC screws provided in the horizontal mounting holes (the outer slots). Adjust electric strike
horizontally until exit device latch fully engages with the door closed.
NOTE: Ensure a 1/16" [1.5mm] clearance between exit
device latch and the electric strike keeper is maintained.
Failing to do so will preload the strike and in turn will not
allow the strike to release the door upon energizing.
LATCH
1/16"
MINIMUM
STRIKE KEEPER
8. Tighten the two mounting screws and check operation. Adjust the horizontal position of electric strike as required.
9. Use the electric strike as a template to mark the two locking holes. Remove strike. Drill & tap for 1/4-20 UNC locking screws. Using
the 1/4-20 UNC screws provided secure the electric strike through the locking holes.
10. A dead latch shim is provided in each hardware kit. This can be used to prevent a deadlatch from falling into the strike cavity.
DEADLATCH SHIM
M3 SCREW
KEEPER
#1/4-20 UNC
(2 PLACES)
DOOR STOP
DOOR
LOCKING
SCREW
(2 PLACES)
5/8" (16mm)
WIRE ACCESS HOLE
(LM SWITCH)
5/8" (16mm)
WIRE ACCESS HOLE
(POWER)
MOUNTING SCREW
(2 PLACES)
FRAME
EXIT DEVICE
NOTE: Wire access hole locations are relative to the exit device orientation.
NOTE: *Second wire access hole required for 0163LM only NOTE: Not to scale. Specifications are subject to change without notice.

advertisement

Key Features

  • Fail-secure operation for enhanced security
  • Compatible with various access control systems for seamless integration
  • Adjustable latch projection to maximize holding force
  • Durable construction for long-lasting performance
  • Easy installation process to minimize downtime
  • Ideal for use in commercial and residential applications

Related manuals

Frequently Answers and Questions

What is the maximum latch projection of the strike?
The maximum latch projection is essential to obtain full holding force.
What is the duty cycle of the strike?
The strike has an intermittent duty cycle for 12VDC AC and a continuous duty cycle for 12VDC DC and 24VDC AC/DC.
What type of wire connections are required?
For 12VDC or 12-24VAC or 11-16VAC input power, connect RED and BLUE wires to positive (+), and connect BLACK and YELLOW wires to negative (-). For 24VDC input power only, connect YELLOW and BLUE wires together, connect RED wire to positive (+), and connect BLACK wire to negative (-).