ICI Titan 1280 P-Series Acoustic Image Management and Signal Analysis User Manual

Add to My manuals
20 Pages

advertisement

ICI Titan 1280 P-Series Acoustic Image Management and Signal Analysis User Manual | Manualzz
Edit Text
Out
Industry
Ind
Revision: 03.2024-002
TITAN 1280 P-SERIES & TITAN BB
USER MANUAL
PLEASE READ THIS MANUAL BEFORE SWITCHING THE UNIT ON.
IMPORTANT SAFETY INFORMATION INSIDE.
ICI cameras fall under US Federal Law and Export Control.
2105 W. Cardinal Dr. Beaumont, TX 77705
For more information, contact us: (409) 861-0788 | [email protected] | www.infraredcameras.com
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
Revision History
03.2024-001
03.2024-002
2
Document created
Grammar corrections
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
Contents
1.
2.
3.
4.
5.
Disclaimers���������������������������������������������������������� 4
1-1
Terms and Conditions�������������������������������������������������������������������������4
1-2
U.S. Government Regulations�������������������������������������������������������������4
1-3
Copyright ���������������������������������������������������������������������������������������������4
1-4
Quality Assurance ������������������������������������������������������������������������������4
1-5
Customer Help�������������������������������������������������������������������������������������4
User Notice���������������������������������������������������������� 5
2-1
Calibration������������������������������������������������������������������������������������������� 5
2-2
Accuracy��������������������������������������������������������������������������������������������� 5
2-3
Cybersecurity������������������������������������������������������������������������������������� 5
2-4
Disposal of Electronic Waste ������������������������������������������������������������ 5
2-5
Intended Use �������������������������������������������������������������������������������������6
2-6
Manual Update�����������������������������������������������������������������������������������6
2-7
Scope of Application �������������������������������������������������������������������������6
2-8
Authoritative Versions ����������������������������������������������������������������������6
2-9
Training ���������������������������������������������������������������������������������������������� 7
Safety Information��������������������������������������������������� 8
Technical Specifications�������������������������������������������� 10
Structure������������������������������������������������������������ 12
5-1
Appearance and Definitions of Housing Interface������������������������ 12
6.
Package Includes��������������������������������������������������� 13
7.
Quick Start Instructions��������������������������������������������� 14
8.
9.
7-1
Plug n’ Play Setup���������������������������������������������������������������������������� 14
7-2
Tripod Setup������������������������������������������������������������������������������������ 15
7-3
Software������������������������������������������������������������������������������������������� 16
Operation Instructions���������������������������������������������� 17
8-1
Power On/Off the Device���������������������������������������������������������������� 17
8-2
IR Flash Pro��������������������������������������������������������������������������������������� 17
Cleaning and Maintenance������������������������������������������ 18
9-1
10.
11.
Cleaning the Germanium Lens��������������������������������������������������������� 18
9-2
Disinfecting the Camera Surface���������������������������������������������������� 18
9-3
Device Calibration����������������������������������������������������������������������������� 18
9-4
Storage���������������������������������������������������������������������������������������������� 18
Troubleshooting����������������������������������������������������� 19
10-1
Thermal imager does not power on������������������������������������������������ 19
10-2
Thermal imager shuts off unexpectedly���������������������������������������� 19
10-3
No thermal image���������������������������������������������������������������������������� 19
10-4
Unclear or dark visible images������������������������������������������������������� 19
10-5
Temperature readings are incorrect���������������������������������������������� 19
About ICI������������������������������������������������������������20
3
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
1.
Disclaimers
1-1
Terms and Conditions
Warranty Terms and Condition of Sale are made available online at:
https://thermalcamera.com/support/terms-and-conditions-of-sale/
1-2 U.S. Government Regulations
This product may be subject to U.S. Export Regulations. Please send any
inquiries to [email protected]
1-3 Copyright
© 2024, Thermal Camera. All rights reserved worldwide. No parts of the
software including source code may be reproduced, transmitted, transcribed
or translated into any language or computer language in any form or by any
means, electronic, magnetic, optical, manual or otherwise, without the prior
written permission of Thermal Camera
The documentation must not, in whole or part, be copied, photocopied,
reproduced, translated or transmitted to any electronic medium or machine
readable form without prior consent, in writing, from Thermal Camera Names
and marks appearing on the products herein are either registered trademarks
or trademarks of Thermal Camera and/or its subsidiaries. All other trademarks,
trade names or company names referenced herein are used for identification
only and are the property of their respective owners.
1-4 Quality Assurance
Thermal Camera is committed to a policy of continuous development; therefore
we reserve the right to make changes and improvements on any of the products
without prior notice.
1-5 Customer Help
For customer help, visit:
https://thermalcamera.com/support/
E-mail:
4
[email protected]
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
2.
User Notice
2-1
Calibration
Annual calibration to the thermal camera is recommended. Contact customer
service to schedule maintenance.
2-2
Accuracy
For very accurate results, we recommend that you wait a minimum of 5 minutes
after you have started the camera before measuring a temperature.
2-3
Cybersecurity
After the products are connected to the Internet, they may face risks including
but not limited to network attacks, hacker attacks, virus infections, etc. The
company will not be responsible for the abnormal operation of the products and
any loss or liability caused therefrom shall be at your own risk.
2-4
Disposal of Electronic Waste
Electrical and electronic equipment (EEE) contains materials, components and
substances that may be hazardous and present a risk to human health and
the environment when waste electrical and electronic equipment (WEEE) is not
handled correctly.
Equipment marked with the below crossed-out wheeled bin is electrical and
electronic equipment. The crossed-out wheeled bin symbol indicates that
waste electrical and electronic equipment should not be discarded together
with unseparated household waste, but must be collected separately.
All local authorities have established collection schemes under which residents
can dispose of equipment at a recycling center or other collection points, or
WEEE will be collected directly from households. More detailed information is
available from the administration of the relevant local authority. Always dispose
of waste in accordance with local, state, and federal regulations.
5
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
2-5
Intended Use
Titan 1280 cores are highly accurate thermal imagers capable of capturing
data in as little as 3 seconds. It supports full-screen temperature data
output and features multiple image output interfaces. The Titan 1280
offers comprehensive analysis functions and can serve a wide range of
temperature measurement applications.
Environment of use: industrial and petrochemical buildings, electrical plants,
security rooms, science labs, environmental conservatories, among others.
You agree that this product is for civilian use only, and shall not use applications
that may infringe the rights of third parties, medical and safety devices or other
applications where product failure may lead to life-threatening or personal injury,
as well as weapons of mass destruction, chemical and biological weapons,
nuclear explosions, unsafe use of nuclear energy, dangerous or humanitarian
purposes. Any loss or liability caused therefrom shall be at the your own risk.
2-6
Manual Update
The user manual will be updated from time to time. To access the latest manuals,
translations of manuals, and notifications, go to:
https://thermalcamera.com/product-resources/
The manufacturer reserves the right to alter the specifications of the product
without prior notification. The manufacturer allows himself the right to modify
without any preliminary opinion the technical specifications of the product.
2-7
Scope of Application
Thermal Camera issues generic manuals that cover several cameras within a
model line.
This means that this manual may contain descriptions and explanations that do
not apply to your particular camera model. This manual may contain technical
inaccuracies or typographical errors.
2-8
Authoritative Versions
The authoritative version of this publication is English. In the event of
divergences due to translation errors, the English text has precedence.
Any late changes are first implemented in English. Other languages may or may
not be available.
6
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
2-9
Training
To read about infrared training, visit:
https://infraredtraininginstitute.com/
7
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
3.
8
Safety Information
•
Operation is subject to the following two conditions: 1 This device may not
cause harmful interference, and 2 this device must accept any interference
received, including interference that may cause undesired operation.
•
This device must be installed by qualified service personnel or system
installation personnel.
•
Do not disassemble or modify the thermal device. If the device operates
abnormally, please contact the supplier and do not dismantle the device
on your own.
•
Do not point the imager (with or without the lens cover) at intensive energy
sources, e.g. devices that emit laser radiation, or the sun. This can affect
the accuracy of the camera, and cause damage to the detector.
•
Do not use the imager in temperatures higher than 150°C (302°F) or
lower than -20°C (-4°F). High/low temperatures can cause damage to the
device.
•
Do not cut, alter, or place heavy items on the device. These actions may
cause an electric short leading to fire or electrocution.
•
Prior to start of the device, make sure that the power supply is properly
connected. If the power supply is connected incorrectly, the device may
be damaged.
•
Do not put holes in the device with objects. Damage to the device may occur.
•
Do not hit the device with a hammer or apply strong impacts or electric
shocks to it. Damage to the device may occur.
•
Do not put the device in or near a fire, stove or other high-temperature
locations. Damage or ignition of the device may occur.
•
Do not put the device in direct sunlight or other high-temperature locations.
Damage or ignition of the device may occur.
•
Do not get water or salt water on the device or permit the device to get
wet. Damage to the device may occur.
•
Remove any water or moisture on the device before you install it. Damage
to the device may occur.
•
If there are fluids on the device and the fluid gets into the eyes, do not rub
the eyes. Flush well with water and immediately get medical care.
•
Always dispose of device in accordance with local, state and federal
regulations.
•
Do not use the device if, when used, there is a smoke emitted from the
device, the device feels excessively hot, changes color, changes shape, or
is in an unusual condition. Speak with a sales office if one or more of these
problems occurs.
•
Do not use liquids to clean the electronics.
•
Clean the case with a damp cloth and a weak soap solution. Do not use
abrasives, isopropyl alcohol, or solvents to clean the case or lens/screen.
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
•
Be careful when cleaning the infrared lens. Do not clean the infrared lens
too vigorously. This can damage the anti-reflective coating.
•
Avoid condensation. Taking the device from cold to hot will cause
condensation in the thermal imager. To protect the device, power on the
device and wait until it becomes warm enough for the condensation to
evaporate.
•
Keep device out of reach of children.
•
This product is a precise electronic device that must be handled with care
during use, storage, and transportation to prevent dangerous actions such
as the device being hit by external force, or falling from heights.
•
Transport: During transportation and storage the original packaging box
must be used.
•
Storage: If you do not use the imager for a long period of time, put the
device in a cool and dry environment.
•
It is recommended to calibrate the device(s) annually.
THE ENCAPSULATION RATING IS ONLY APPLICABLE WHEN ALL THE
OPENINGS ON THE CAMERA ARE SEALED WITH THEIR CORRECT COVERS,
HATCHES, OR CAPS. THIS INCLUDES THE COMPARTMENTS FOR DATA
STORAGE, BATTERIES, AND CONNECTORS.
9
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
4.
Technical Specifications
Titan 1280
Pixel Resolution
1280 x 1024
Accuracy
± 2°C (± 3.6°F) or ± 2%
Temperature Range
Standard: -20°C to 150°C (-4°F to 302°F)/
Industrial:0°C to 500°C (32°F to 932°F)
Operation Range
-40°C to 80°C (-40°F to 176°F)
Storage Range
-45°C to 85°C (-49°F to 185°F)
Detector Type
Uncooled VOx microbolometer
Pixel Pitch
12 μm
Focal Length
17 mm
Focus
Manual
Spectral Band
8 μm to 14 μm
Thermal Sensitivity (NETD)
< (20 mK) 0.02 °C at 30 °C (86°F)
Pixel Operability
> 99 %
Shock
40 G
Vibration
4.3 G
Frame Rate
30 Hz
Dimensions (without lens)
Power
45 mm x 45 mm (W x H ± 0.5 mm)
(1.77” x 1.77” (W x H ± 0.02”))
4V ~ 6V DC, < 2.3W
Power Protection
Over-voltage; Under-voltage; Reverse Connection
Startup Time
≤15s
Weight (without lens)
< 150 g (5.29 oz) ± 3 g (0.11 oz)
Interface
USB Type-C
Video
LVCMOS; LVDS
Video Mirror
Horizontal; Vertical; Diagonal
Image Polarity
Image Processing
Recticle
20 options
Digital filter; Imaging denoising; Detail enhancement
Reveal; Hidden; Shift
Brightness
Zoom
Adjustable
1.0X ~ 4.0X continuous zoom
IP Rating
IP54
Palette support
Internal non-uniformity correction (NUC)
10
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
Titan BB
Pixel Resolution
1280 x 1024
Accuracy
± 2°C (± 3.6°F) or ± 2%
Temperature Range
Standard: -20°C to 150°C (-4°F to 302°F)/
Industrial:0°C to 500°C (32°F to 932°F)
Operation Range
-40°C to 80°C (-40°F to 176°F)
Storage Range
-45°C to 85°C (-49°F to 185°F)
Detector Type
Uncooled VOx microbolometer
Pixel Pitch
12 μm
Focal Length
17 mm
Focus
Manual
Spectral Band
3 μm to 13.5 μm
Thermal Sensitivity (NETD)
< (20 mK) 0.02 °C at 30 °C (86°F)
Pixel Operability
> 99 %
Shock
40 G
Vibration
4.3 G
Frame Rate
30 Hz
Dimensions (without lens)
Power
45 mm x 45 mm (W x H ± 0.5 mm)
(1.77” x 1.77” (W x H ± 0.02”))
4V ~ 6V DC, < 2.3W
Power Protection
Over-voltage; Under-voltage; Reverse Connection
Startup Time
≤15s
Weight (without lens)
< 150 g (5.29 oz) ± 3 g (0.11 oz)
Interface
USB Type-C
Video
LVCMOS; LVDS
Video Mirror
Horizontal; Vertical; Diagonal
Image Polarity
Image Processing
20 options
Digital filter; Imaging denoising; Detail enhancement
Recticle
Reveal; Hidden; Shift
Brightness
Adjustable
Zoom
1.0X ~ 4.0X continuous zoom
IP Rating
IP54
Palette support
Internal non-uniformity correction (NUC)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
11
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
5.
Structure
5-1
Appearance and Definitions of Housing Interface
1.
2.
1.
Germanium Lens
2.
USB Type-C Slot
12
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
6.
Package Includes
Titan Series Camera
USB to USB Type-C Cable
Software USB Drive
ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT
BEFORE BEGINNING INSTALLATION
13
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
7.
Quick Start Instructions
7-1
Plug n’ Play Setup
A.
B.
Plug the Type-C end of the USB
cable into the back of the Titan
Series camera.
Plug the other end of the USB
cable into your computer.
3.
Power on computer.
14
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
7-2
Tripod Setup
A.
Mount the Titan Series camera to a
tripod using the ¼-20 mount.
B.
Plug the Type-C end of the USB
cable into the back of the Titan
Series camera.
MAKE SURE TRIPODS DO NOT BLOCK THE DIRECT PATH OF FOOT TRAFFIC TO
ENSURE THE EQUIPMENT WILL NOT BE MOVED OR KNOCKED DOWN. USING A
DIVIDING BARRIER WILL HELP KEEP TRIPODS SEPARATE FROM PATHS.
15
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
C.
Plug the other end of the USB
cable into your computer.
7-3
16
D.
Power on computer.
Software
A.
B.
Install IR Flash software using the
software USB drive. Refer to the IR
Flash User Manual for instructions.
Once installed, launch IR Flash
software by double-clicking the
associated desktop icon.
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
8.
Operation Instructions
8-1
Power On/Off the Device
After installing the thermal camera in the preferred position, use the cable to
connect the thermal camera and the computer as normal. The device pulls
power from the computer and powers on when the computer is powered on.
Temperature measurement and analysis is most accurate after 10 minutes.
Monitoring is available through the computer software (see Chapter 8-2 IR Flash
Pro)
THE THERMAL IMAGER NEEDS SUFFICIENT TIME TO WARM-UP FOR THE MOST
ACCURATE TEMPERATURE MEASUREMENTS AND BEST IMAGE QUALITY.
THIS TIME CAN OFTEN VARY BY ENVIRONMENTAL CONDITIONS. IT IS BEST
TO WAIT A MINIMUM OF 10 MINUTES FOR THE DEVICE TO COMPLETELY
WARM-UP.
AFTER POWERING OFF, WAIT TEN SECONDS BEFORE ATTEMPTING TO
POWER THE DEVICE ON AGAIN.
8-2
IR Flash Pro
Software arrives installed on computers and tablets purchased from ICI as
complete systems and it will launch automatically on startup. A copy of the
software is provided on the Software USB Drive. Documentation can be found
online on the IR Flash Pro web page under the Downloads section or at this
address:
https://infraredcameras.com/ir-flash-pro-manual/
•
•
•
•
•
Processor: Intel i5 Quad core or above
RAM: 4 GB or above
OS: Windows 8/8.1/10
Hard Drive: 256 GB or above
Resolution: 1920 x 1080
17
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
9.
Cleaning and Maintenance
9-1
Cleaning the Germanium Lens
Do not use corrosive chemicals on the optical glass components. The germanium
window surface is coated with anti-reflection coating. Dust, grease, and
fingerprints will produce harmful substances and lead to a decline in performance,
or cause scratches. If dirt is found, please use the following methods:
1.
Use a blown balloon or a soft brush to clean the lens surface to avoid dust
particles scratching the anti-reflection film on lens surface during the
wiping process.
2.
Use a soft cotton or microfiber cloth or lens wiping paper and dip in distilled
water. Gently wipe the lens surface from the middle to the edge, paying
attention to not crack the lens, or use too much liquid. If the lens is still not
clean, replace the cloth and repeat the wiping process.
9-2
Disinfecting the Camera Surface
Do not use corrosive cleaning solutions on the optical glass components. It is
recommended to disinfect the camera surface regularly with a non-corrosive
sanitizing product. Follow the directions provided by the manufacturer of the
cleaning solution. Adhere to the sanitation protocols and cleaning schedule set
forth by the employer.
9-3 Device Calibration
It is recommended to have the device(s) re-calibrated annually. Contact
customer service to schedule maintenance.
9-4 Storage
When the equipment is not in use, the device should be placed in a dust-free
and moisture-free environment with a stable temperature and humidity.
DO NOT USE CORROSIVE CLEANING SOLUTIONS ON THE OPTICAL GLASS
COMPONENTS. DISINFECT THE CAMERA SURFACE REGULARLY WITH A NONCORROSIVE SANITIZING PRODUCT.
CALIBRATE YOUR DEVICES ANNUALLY. CONTACT CUSTOMER SERVICE TO
SCHEDULE MAINTENANCE.
18
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
10.
Troubleshooting
If the user encounters any problems while using the imager, refer to the following
options. If the problem persists, disconnect the power and contact the customer
support department.
10-1 Thermal imager does not power on
•
Ensure the cables are plugged in correctly
•
Unplug the cable and plug it back in
•
Power off the device; then, power it back on
•
Power off the computer and power it back on
10-2 Thermal imager shuts off unexpectedly
•
Ensure the cables are plugged in correctly
10-3 No thermal image
•
Open the lens cap
•
If lens is foggy, use professional equipment to clean the lens
10-4 Unclear or dark visible images
•
Turn on lights in imaging area
•
If lens is foggy, use professional equipment to clean the lens
10-5 Temperature readings are incorrect
•
Power off the device; then, power it back on
•
Ensure the correct temperature range is selected
◦
The default temperature range is -20 °C to 150 °C (-4 °F to 302 °F)
◦
When measuring high temperature objects ensure the temperature
range is set to the 0 °C to 500 °C (32 °F to 932 °F) range
•
Device is at proper height
•
Ensure device is in focus
•
Perform a NUC operation
19
TITAN 1280 P-SERIES & TITAN BB USER MANUAL
11.
About ICI
Infrared Cameras, Inc.
2105 W. Cardinal Dr.
Beaumont, TX 77705
Phone: (409) 861-0788
Toll Free: (866) 861-0788
International: (409) 861-0788
Hours: Monday – Friday 8:00AM - 5:00PM CST
General Inquiry: [email protected]
Website: www.infraredcameras.com
You may reach a representative by phone or email.
ICI manufactures complete systems and software. We can provide complete
engineering, software, and OEM solutions. Our Fortune 500 clients rely
on us for infrared equipment and thermography training (which we offer
through the Infrared Training Institute).
In addition to providing custom germanium, silica, and sapphire optics, we
also build windows for enclosures, as well as custom pan and tilt units. We
can even provide customizable explosion-proof systems.
Our knowledge and experience stems from years of using infrared
imaging and temperature measurement instruments to provide solutions
to: managers, engineers, scientists, inspectors and operators in space,
power companies, medical, pulp and paper, food industry, research and
development, and various process industries. You can see our products
and services used in industrial, commercial, and government applications
worldwide. Originally named Texas Infrared (still DBA), Infrared Cameras,
Inc. has been in business since March, 1995.
Thank you for your dedicated and continued support.
20

advertisement

Key Features

  • High-resolution 1280x720 thermal sensor for crisp, detailed images
  • 12µm pixel pitch for accurate temperature measurements
  • Wide temperature measurement range (-4°F to 302°F) for versatility
  • Multiple color palettes for easy interpretation of thermal data
  • Advanced image processing algorithms for enhanced clarity
  • Built-in flashlight for illumination in low-light conditions
  • Rugged design for durability in harsh environments
  • Easy-to-use interface for quick setup and operation

Related manuals

Frequently Answers and Questions

How does the annual calibration process help improve the accuracy of the camera?
The process ensures that the camera is consistently producing accurate temperature measurements.
How do I update the software on the camera?
Software updates can be downloaded from the manufacturer's website.
What is the intended use of the camera?
The camera is intended for use in electrical inspections, building diagnostics, and predictive maintenance.
How do I clean the lens?
Use a soft, clean cloth to wipe the lens.

advertisement