Data 110-2
12/17/2009
Eclipse RatioMatic
Burners
Model RM100
Version 3
Maximum Input, BTU/hr (kW)
Note: Contact factory for varying chamber pressures or pressures outside the range
-2.0 to 2.0" w.c. (-5,0 to 5,0 mbar)
Flame Detection
Fuel
Parameter
Minimum Input On-Ratio, BTU/hr (kW)
Main Gas Inlet Pressure, "w.c. (mbar)
• Fuel pressure at ratio regulator inlet
High Fire Flame Length, inches (mm)
• Measured from the outlet end of the combustor
Maximum Chamber Temperature, °F (°C)
Frequency
60 Hz
Packaged
Burner
Specification
BTU/hr (kW)
1,295,00 (379)
1,210,000 (354)
1,120,000 (328)
1,020,000 (298)
915,000 (268)
"w.c. (mbar)
-2.0 (-5,0)
-1.0 (-2,5)
0.0 (0,0)
1.0 (2,5)
2.0 (5,0)
50 Hz
Packaged
Blower
1,375,000 (403)
1,295,000 (379)
1,210,000 (354)
1,120,000 (328)
-2.0 (-5,0)
-1.0 (-2,5)
0.0 (0,0)
1.0 (2,5) with high turndown ratio regulator with standard ratio regulator
1,020,000 (298)
30,000
(9)
40,000
(12)
10 to 20
(25 to 50)
32 (813)
2.0 (5,0)
Natural Gas
Propane / Butane
Alloy Tube
38 (965)
1500 (820)
SiC Tube 1900 (1040)
Flame rod or UV scanner
Natural Gas, Propane, Butane
(For any other mixed gas, contact Eclipse Inc.)
• All information is based on laboratory testing. Different chamber size and conditions will affect the data.
• Maximum inputs are given for the standard combustion air blower without an air filter.
• All inputs based upon gross calorific values and standard conditions; 1 atmosphere, 70°F (21°C).
• Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly.
2
1000
100
10
1
0
0
Control & Operation Zone
Performance Graphs
Typical Control
Ratio
200
Input and excess air at low fire changes with ratio regulator adjustment.
400 600 800
Input (x 1000 BTU/hr)
50 100 150 200
Input (kW)
250
1000
300
1200
350
100
90
80
70
60
50
40
0
0
NO
X
Emission Data
Natural Gas
Propane/Butane
200 400 600 800
Input (x 1000 BTU/hr)
50 100 150 200
Input (kW)
250
1000
300
1200
350
5.0
3.7
2.5
1.2
0.0
11.2
10.0
8.7
7.5
6.2
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
0
Fuel Orifice ∆p vs. Input
∆p Measured Between Taps B & D
Butane (13.5 mm Orifice)
Propane (15.0 mm Orifice)
Natural Gas (19.0 mm Orifice)
14
200 400 600 800 1000 1200
Input (x 1000 BTU/hr)
50 100 150 200 250 300 350
Input (kW)
12
10
8
6
4
2
0
NO
X
emission data is given for:
• Ambient combustion air ~70°F (20°C)
• Less than 700°F (370°C) firing chamber
• Minimal process air velocity
• Low fire input adjusted to 40,000 BTU/hr (12 kW)
• ppm volume, dry @ 3% O
2
• Neutral chamber pressure
Emissions are influenced by:
• Chamber conditions
• Fuel type
• Firing rate
• Ratio regulator adjustment
• Combustion air temperature
CO emission is largely influenced by chamber conditions.
Contact your local Eclipse Combustion representative for an estimate of CO emission on your application
6.0
Air ∆p vs. Air Flow
High Fire Air ∆p 5.9" w.c. (14.7 mbar)
(Neutral Chamber)
5.0
4.0
3.0
2.0
1.0
0.0
0
0
2000 4000 6000 8000 10000 12000
Air Flow X 1000 scfh
50 100 150 200 250 300 350
Air Flow Nm³/hr
Eclipse RatioAir RM100, V3, Data 110-2, 12/17/2009
771
(30.4)
236
(9.3)
Dimensions & Specifications
Dimensions in Inches (mm)
341
(13.4)
290
(11.4)
Blower housing
Filter housing
C
Filter/silencer option shown in gray.
Low Fire
Premix Line
Propane/Butane
35
(1.4)
Tap C
1" NPT or BSP gas inlet
Weights
Packaged Burner
Filter Silencer
1/2" NPT
Pilot Option
428
(16.8)
Tap B
Tap D 300
(11.8)
Flame rod or
UV scanner
1/2" NPT lbs
75
41 kg
35
19
D
Gas inlet centerline
A
185
(7.3)
87
(3.4)
2.5"
NPT or Rc
125.5
(4.94)
A B
50 Hz 485 (19.1) 530 (20.9)
C
N/A
D
N/A
60 Hz 425 (16.7) 475 (18.7) 10 (0.4) 23 (0.9)
Less Blower Option
B
9 (0.4)
Alloy Tube
F
E
E
255 (10.0)
330 (13.0)
406 (16.0)
Ø 114
(4.5) OD
190
(7.5)
F
84 (3.3)
160 (6.3)
236 (9.3)
Combustor Types
4 x Ø 12 (0.47)
Ø 165 (6.49) bolt circle
SiC Tube
320
(12.6)
Ø 120
(4.7) OD
20 (0.8)
4 x Ø 12
(0.47)
Ø 165 (6.49) bolt circle
Eclipse RatioAir RM100, V3, Data 110-2, 12/17/2009 3
Upright left hand piping
Burner Configuration
Inverted left hand piping
Upright right hand piping
Inverted right hand piping
Data 110-2, 12/17/2009
Offered By:
Burnerparts.com
2011 Williamsburg Road
Richmond, Virginia 23231
Phone (804) 236-3881
Fax (804) 236-3882 www.burnerparts.com