Modem 32144
Modem 32144 Card
NOVEMBER 2002
MD833A-R6
MD833AE-R6
MD833C-R5
MD833A-D12
MD833A-D24
MD833A-D48
1
2
3
➝
1
2
MODEM 32144
3
➝
ENT
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
FCC STATEMENT
FEDERAL COMMUNICATIONS COMMISSION
AND
INDUSTRY CANADA
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Indusrty
Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
1
INSTRUCCIONES DE SEGURIDAD
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos
(incluyendo amplificadores) que producen calor.
2
INSTRUCCIONES DE SEGURIDAD
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
3
TRADEMARKS
TRADEMARKS
All applied-for and registered trademarks are the property of their respective owners.
4
MODEM 32144
Contents
1. Specifications.............................................................................................10
2. Quick Start.................................................................................................13
2.1 Installation ........................................................................................13
2.1.1 Unpacking...............................................................................13
2.1.2 Connections ............................................................................14
2.1.3 Jumpers ...................................................................................15
2.2 Front-Panel LCD and Controls .......................................................16
2.2.1 Power-On Screen ....................................................................17
2.2.2 EIA Status Screen....................................................................17
2.3 Quick Setup ......................................................................................18
2.3.1 How to Select a Quick Setup .................................................18
2.4 Basic Operation ................................................................................25
2.4.1 2-Wire Dial Hayes Mode (Quick Setup 1) ............................25
2.4.2 2-Wire Dial V.25 bis Mode (Quick Setup 2-4).......................26
2.4.3 2-Wire Dial Dumb Mode (Quick Setup 5)............................27
2.5 Leased Line (2- or 4-Wire) Mode (Quick Setup 6-9) ....................29
2.6 V.33 Leased Line Operation (Quick Setup 10) .............................29
2.7 2-Wire Dial Bell 208 Operation (Quick Setup 11-12)....................30
2.8 Two Types of Bell 208 Operation ....................................................31
2.8.1 Bell 208 Operation (Exclusive) .............................................31
2.8.2 V.32/208 Auto-Select Mode ...................................................32
2.9 4-Wire Leased Line V.29 Mode (Quick Setup 13) .........................32
2.9.1 V.32 Dial Backup.....................................................................33
2.10 V.29 Fast Master and Slave Modes (Quick Setup 14-15) ..............33
2.11 If You Have Problems.....................................................................35
2.11.1 All Modes...............................................................................35
2.11.2 All Dial Modes (Hayes, V.25 bis, Dumb, Bell 208, and V.32/208).......................................................................35
2.11.3 All Asynchronous Modes......................................................37
2.11.4 Hayes Mode...........................................................................37
2.11.5 All Leased-Line Modes (2-Wire, 4-Wire, V.33, and V.29) ...............................................................................37
2.11.6 Leased Line (Excluding V.33 and V.29 Operation)...........37
3. Options: Customizing the Modem Setup...............................................38
3.1 Methods for Selecting Options .......................................................38
3.2 Front-Panel Options.........................................................................38
3.2.1 Pushbuttons and the LCD .....................................................38
5
MODEM 32144
3.3 Selecting Options from the Front Panel ........................................40
3.3.1 DEC/INC (Decrease/Increase) Screens ..............................41
3.3.2 Example of How to Select an Option ...................................42
3.3.3 How to Return to the EIA Status Screen ..............................43
3.3.4 Automatic Configuration Save Feature.................................43
3.3.5 How to Return to Default Settings ........................................43
3.4 Options..............................................................................................44
3.5 Speed (Data Rate) Options .............................................................44
3.6 V.42 Error Correction Options........................................................48
3.7 Address..............................................................................................54
3.8 Dialer Mode ......................................................................................55
3.9 Auto-Answer Option ........................................................................55
3.10 Data Format Options .....................................................................56
3.11 Disconnect Options........................................................................57
3.12 Test Options.....................................................................................58
3.13 EIA Options .....................................................................................58
3.14 Modem Setups ................................................................................60
3.15 V.33 and Bell 208A/B Options ......................................................65
3.16 Options Accessible Only via Summary Setup...............................67
3.16.1 Dial Line Options .................................................................67
3.16.2 V.42 Error-Correction Options ............................................67
3.16.3 Data Pump Options..............................................................69
3.16.4 Miscellaneous Options .........................................................70
4.0 General Operation and Special Features ..............................................74
4.1 Quick Reset.......................................................................................74
4.2 Storing Phone Numbers ..................................................................74
4.2.1 Uses..........................................................................................74
4.2.2 How to Store a Phone Number .............................................75
4.3 Automatic Fallback...........................................................................77
4.3.1 Operating-Mode Fallback ......................................................77
4.3.2 Automatic Rate Adjustment...................................................79
4.4 Dumb Mode and Bell 208 Operation .............................................80
4.4.1 Manual Originate/Answer Operation ..................................80
4.5 V.32/208 Auto-Detect Mode............................................................81
4.5.1 V.32/V.32 bis Operation.........................................................81
4.5.2 Bell 208 Operation .................................................................82
4.5.3 Automatic Fallback .................................................................82
4.6 V.13 Operation .................................................................................82
4.7 DTR Dialing......................................................................................82
4.7.1 Dialing a Stored Number.......................................................83
4.7.2 Answer Mode Operation........................................................83
6
MODEM 32144
4.8 Dial Line Auto-Recovery ..................................................................83
4.8.1 Setting Up the Modem for Dial Line Auto-
Recovery ..................................................................................83
4.8.2 Recovery Procedure ...............................................................84
4.9 Leased Line Auto-Recovery .............................................................84
4.9.1 Autodial Backup .....................................................................85
4.9.2 Exit from Leased Line Auto-Recovery ..................................85
4.9.3 Leased-Line Auto-Recovery Options.....................................86
4.10 Modem Security Operation...........................................................87
4.11 Automatic Password Protection (APP) ..........................................87
4.12 Configuring Modems for APP.......................................................89
4.12.1 APP Without Callback ..........................................................89
4.12.2 APP With Callback................................................................89
4.12.3 Password Screens ..................................................................89
4.12.4 Valid Password Characters ...................................................90
4.12.5 APP with Callback: Storing the Password with
Callback Number..................................................................91
4.13 Disabling APP .................................................................................91
4.13.1 Temporarily Disabling APP..................................................91
4.13.2 Clearing the Password ..........................................................92
4.14 Manual-Response Password Protection (MPP)............................92
4.15 Commands for Enabling MPP.......................................................93
4.16 How to Use Password Commands.................................................94
5. Hayes Emulation Mode ............................................................................97
5.1 Hayes Mode Autodialer ...................................................................97
5.1.1 Enabling the Hayes Mode Autodialer...................................97
5.1.2 Command Guidelines ............................................................97
5.2 Result Codes .....................................................................................99
5.3 Transmission Speed........................................................................100
5.4 Hayes Compatible Commands ......................................................101
5.5 S Registers .......................................................................................107
5.5.1 Reading and Setting Registers .............................................107
5.5.2 S Register Functions .............................................................108
5.6 Saving Option Selections ...............................................................110
5.7 Facsimile (Fax) Transmission ........................................................111
5.8 Hayes Mode Reference Tables ......................................................111
6. V.25bis Autodialer ...................................................................................127
6.1 Enabling the V.25bis Autodialer....................................................127
6.1.1 Quick Setup ..........................................................................127
6.1.2 2=Dialer Mode (DIAL V.25 bis Screen) ..............................128
6.1.3 DTR Dialing in V.25 bis Mode .............................................128
6.2 V.25 bis Autodialer Commands .....................................................128
6.3 Dialing Parameters .........................................................................132
6.4 V.25 bis Result Codes .....................................................................134
7
MODEM 32144
6.5 Message Format ..............................................................................136
6.5.1 Asynchronous........................................................................136
6.5.2 Synchronous, Character-Oriented ......................................136
6.5.3 Synchronous, Bit-Oriented ..................................................137
7. Diagnostics...............................................................................................138
7.1 When and Why to Test ...................................................................138
7.2 Symptoms and Scope of the Problem...........................................138
7.3 Physical Inspection.........................................................................139
7.4 Overview of Modem Diagnostics...................................................139
7.5 How to Select and Activate Tests ...................................................140
7.5.1 Front-Panel Control .............................................................140
7.5.2 Running Tests in Hayes Mode .............................................140
7.5.3 Remote Test Control ............................................................140
7.6 Diagnostic Monitoring: Status Screens ........................................140
7.6.1 EIA Status Screen .................................................................140
7.6.2 Other Status Screens ............................................................141
7.7 Rate Change Screen.......................................................................143
7.8 Local Modem Diagnostics .............................................................144
7.8.1 Analog Loopback (ALB) Test..............................................144
7.8.2 Analog Loopback Self-Test (ALBST) ..................................145
7.8.3 Analog Loopback Self-Test with Errors (ST/E) .................147
7.8.4 External Analog Loopback (ALBX) Test............................147
7.8.5 External Analog Loopback Self-Test (ALXST) ..................149
7.8.6 Digital Loopback Test (DLB) ..............................................151
7.9 Remote Modem Diagnostics..........................................................153
7.9.1 Remote Digital Loopback (RDL) Test ................................153
7.9.2 Remote Digital Loopback Self-Test (RDLST) ....................154
Appendix A: Quick Setup Configurations ................................................156
Appendix B: Summary Setup .....................................................................166
B.1 Summary Setup LCD Screens .......................................................166
B.2 Changing Options via Summary Setup ........................................167
B.2.1 Summary Setup Pushbutton Functions..............................167
B.2.2 Explanation of Summary Setup Screens ............................168
Appendix C: Connectors, Adapters, and Jumpers ...................................176
C.1 Connectors and Adapters .............................................................177
C.1.1 Connector Pin Assignments................................................178
C.2 Jumpers...........................................................................................179
8
MODEM 32144
Appendix D: DC Voltage Models ...............................................................181
D.1 Introduction...................................................................................181
D.2 Installation .....................................................................................182
D.3 Jumper Settings .............................................................................183
D.4 Jumper Locations ..........................................................................184
Appendix E: LCD Flow Chart ....................................................................185
9
MODEM 32144
1. Specifications
Standards: Bell 103, 212, 208, CCITT V.13,
V.17, V.22, V.32, V.22 bis, V.25, V.32 bis,
V.33, V.29, V.32terbo
Protocol: Sync and async
Data Rate: Up to 16.8 and 19.2 kbps
Operation: Full duplex over 2- or 4-wire leased lines or dialup lines
Connectors: (1) DB25 female, (5) RJ-45 female, (1) 5-pin DIN
Configuration: AT Command set or front-panel
Error Correction/Data Compression:
MNP 1-5, V.42, V.42 bis
Ringer Equivalence: 0.8 B
Environment: Ambient temperature:
32 to 122° F (0 to 50° C); Storage temperature: -4 to +158° F (-20 to +70° C);
Relative humidity: 10 to 95%
Power: 90-132 VAC, 60 Hz
Size: 2.5"H x 10.1"W x 9.7"D (6.4 x 25.7 x
24.6 cm)
Weight: 4 lb. (1.8 kg)
10
CHAPTER 1: Specifications
15
17
18
20
7
8
9
10
21
5
6
3
4
1
2
Pin
Table 1-1. Pin Assignments—EIA Interface Connector
Designation Function LCD Indicator Source
DB
DD
CN
CD
AB
CF
+P
-P
CN
AA
BA
BB
CA
CB
CC
Frame ground—not connected
Transmit (send) data (TD) TD
Received data (RD)
Request to send (RTS)
RD
RS
Clear to send (CTS) CS
Data set (modem) ready (DSR) MR
Signal ground (SG)
Carrier detect (CD)
Testing voltage, +10V
Testing voltage, -10V
Transmit clock (TC)
Receive clock (RC)
Analog loopback control (ALBT)
Data terminal ready (DTR)
Remote digital loopback control
CD
TR
DTE
Modem
DTE
Modem
Modem
Ground
Modem
Modem
Modem
Modem
Modem
DTE
DTE
DTE
11
MODEM 32144
Table 1-1. Pin Assignments—EIA Interface Connector (continued)
Pin Designation Function LCD Indicator Source
22
23
24
25
CE
CH
DA
CN
Ring indicator (RI)
Speed select
External transmit clock
Test mode indicator (TM)
R
TM
Modem
DTE
DTE
Modem
12
2. Quick Start
CHAPTER 2: Quick Start
This instruction manual applies to the Modem 32144.
All information applies to both the stand-alone and full-size rackmount versions of the modem.
Specialized low-profile rack-mount versions, designed for use in highdensity rack enclosures, are described in Appendix A.
QUICK SETUPS FOR A QUICK
START
The simplest and fastest way to set up the modem for immediate use is to select one of the factory-preset
Quick Setup configurations.
For most applications, once you have selected the proper
Quick Setup, the modem will be ready for operation. You will not need to make further adjustments.Quick Setups are explained fully beginning
in Section 2.3, following
installation instructions and a brief introduction to the front panel display and controls.
2.1 Installation
2.1.1 U
NPACKING
Keep the original shipping carton in case you need to return the modem for any reason.
Note that if you ordered the
Modem 32144 Card, all you will receive is the Card itself. It does not come with the power transformer or cables listed below.
If you ordered the Modem 32144
(standalone version, MD833A-R6 or MD833AE-R6), in addition to the modem, the shipping carton should contain—
• A power transformer
(with cable attached),
• (3) RJ-45 cables,
• (1) 10-ft. RS-232 cable,
• (1) DB25 male to DB9 female adapter, and
• This users’ manual.
Three RJ-45 cables are supplied with the modem, but all three cables aren’t always needed, depending on the application. You will need an EIA RS-232 interface cable (included with the MD833A-
R6 and MD833AE-R6) to connect the modem to the DTE (data terminal equipment, usually a computer). If the modem will be operated in a manual dial mode, you will also need a standard telephone set.
13
MODEM 32144
2.1.2 C
ONNECTIONS
Fig. 2-1
shows how the modem is connected to the computer or terminal, power, phone lines, and handset (optional). Do not install
the modem more than 50 feet
(15.2 m) from the DTE.
This is the EIA recommended maximum length for interface cable.
For all applications—
• Connect the modem connector marked “DTE” to the computer or other DTE. Use an EIA
RS-232 interface cable (not supplied with the modem) to make this connection.
• Attach the power transformer cable (supplied with the modem) to the modem receptacle marked “POWER,” and plug the other end into a
115-VAC power outlet.
For dialup applications—
• Connect the modem to the telephone line modular wall jack, as follows: Use the cable
(supplied) that has an eight-pin modular connector on one end and a six-pin modular connector on the other. Plug the eight-pin connector end of the cable into the modem jack labeled “TX DIAL.” Then plug the six-pin connector end into the telephone line modular wall jack. Do not bundle the telephone and EIA interface cables together.
• Optional: If you want to use the telephone line for voice transmissions (when the modem is not operating in data mode) or for manual dial operation, plug a standard telephone set into the jack in the rear of the modem labeled
“PHONE.”
For leased line applications—
• Attach the six-pin modularconnector end of the fourconductor cable (supplied) to the modem connector labeled
“LEASED LINE.” Attach the spade-lug end of the cable into the line terminal block.
The same cable is used whether the leased line is a 4-wire or
2-wire line. In a 4-wire application, the green and red wires are the TRANSMIT pair of wires, and the yellow and black wires are the RECEIVE pair. When the cable is connected to a 2-wire line, only its green and red wires are used
(and the yellow and black wires should be cut off).
14
CHAPTER 2: Quick Start
DTE
REAR PANEL
POWER
LEASED LINE
PHONE
EIA RS-232C
INTERFACE CABLE
WITH DB-25
CONNECTOR
DIAGNOSTIC
CONNECTOR*
DATA TERMINAL
EQUIPMENT
(DTE)
POWER
TRANSFORMER
DIAL
LINE*
LEASED
LINE*
TELEPHONE*
(HANDSET)
* NOT REQUIRED FOR
ALL APPLICATIONS
Fig. 2-1. Installation of the Modem.
2.1.3 J
UMPERS
For most applications, you don’t need to reset internal jumper switches. However, jumper switches must be reset if you need to connect frame ground to signal ground, switch from A/A1 control to MI/MIC control, or use the modem in a DC rack enclosure.
For detailed jumper information, see Appendix C.
15
MODEM 32144
2.2 Front-Panel LCD and Controls
To select a Quick Setup configuration (as explained in the next section), you will need to use the pushbuttons and liquid crystal display (LCD) on the modem’s front panel. These features are shown in Fig. 2-2.
V.32 bis/19.2M
Version 3.02
1 2 3 1 2 3
FRONT PANEL
LIQUID CRYSTAL DISPLAY (LCD)
ENT
PUSHBUTTONS
Fig. 2-2. Pushbuttons and LCD on the Modem’s Front Panel.
For a detailed explanation of the front-panel controls, see Chapter 3.
16
CHAPTER 2: Quick Start
2.2.1 P
OWER
-O
N
S
CREEN
When the modem is powered on, the unit momentarily displays the power-on screen, which typically looks like this:
V.32 bis/19.2M
Version 3.02
The numbers displayed in the lower right corner are the revision levels of the software used in the modem. The software revision levels displayed by your unit may be different than those shown above. If you need to call Technical
Support, please be prepared to give the support group the software revision levels of your unit.
The modem spends about two seconds checking the ROM checksum and doing self-tests and then displays the EIA status screen.
2.2.2 EIA S
TATUS
S
CREEN
The EIA status screen indicates the operational status of the modem as well as the condition of certain EIA
RS-232 leads. The abbreviations that may appear are identified below; however, typically only a few of these abbreviations will be displayed during actual operation.
D TR MR RS CD TD
9600 TM ER CD RD
D=Dial line occupied
R=Ringing (R appears in same position as D.)
S=Connection secured by security handshake (S appears in the same position as D. S and D may flash alternately.)
TR=Data Terminal Ready
MR=Data Set Ready
RS=Request to Send
CS=Clear to Send
TD=Transmit Data
14,400, 9600, 4800, etc.=Data speed in bits per second (“idle” or H-01,
H-14, etc. may also be displayed in the data speed position; see below.)
TM=Test mode
ER=Error (poor signal quality)
CD=Carrier Detect
RD=Receive Data
Codes beginning with “H” (such as H-01) in the lower left corner of the status screen indicate that the modem is handshaking with another modem (attempting to establish a connection). When the modem is off-line, the word “idle” is displayed in the same position.
17
MODEM 32144
2.3 Quick Setup
To quickly set up the modem for immediate use (or to quickly change the modem’s configuration for an alternate mode of operation), select one of the factory-preset Quick Setup configurations. Select the Quick
Setup (Table 1-1) that corresponds to the application you will use.
When you select a Quick Setup, the modem automatically sets all of its options to the settings that are typically most suitable for your application. Selecting a Quick
Setup overwrites previously stored option settings but does not affect telephone numbers which may be stored in the modem’s memory.
Whether you use a Quick Setup configuration “as is” or customize it by changing specific option settings
(Chapter 3), you should begin by selecting the Quick Setup that corresponds to your application.
2.3.1 H
OW TO
S
ELECT A
Q
UICK
S
ETUP
To select (activate) a Quick Setup configuration, follow the steps below. As you do, you may find it helpful to refer to the LCD flow chart that is shipped with the modem.
1. Press the ENT (enter) pushbutton on the modem’s front panel. Screen 1 of the
MAIN MENU will be displayed:
MAIN MENU
TALK QUICK
<1>
DIAL
You will only need to press the
ENT button once if the modem has just been powered up. Otherwise, you may have to press the ENT button two or more times until screen 1 of the MAIN MENU is displayed.
[There are two ways to access the
QUICK SETUP menu: QUICK may be selected from the MAIN MENU, as described above, or from screen
1 of the SETUP menu. See MAIN
MENU screen 1 and SETUP menu screen 1 on the LCD flow chart.]
2. Press pushbutton 2. Screen 1 of the QUICK SETUP menu will be displayed:
QUICK SETUP <1>
2-W DIAL (HAYES)
3. Move to the QUICK SETUP screen that shows the configuration you want. Use the right arrow button to move from QUICK SETUP screen 1 to the QUICK SETUP screen for the configuration you want.
You may also use the left arrow button to move “backward” through the QUICK SETUP menu.
18
CHAPTER 2: Quick Start
There are 15 QUICK SETUP screens, one for each Quick
Setup configuration. For a brief description of each Quick
Setup configuration, see Table
2-1
.
4. When the LCD shows the
Quick Setup configuration you want, press pushbutton 2. This will cause the bottom line of the display to flash on and off.
5. Press the ENT button twice. As you do this, you will see SETUP screen 1; then—after you press the ENT button a second time
—the modem will reset. (It is at this point that the selected
Quick Setup actually takes effect.)
The modem is now set up for the Quick Setup configuration you have selected. All options will be set as shown in Appendix A. If you want to customize the Quick
Setup configuration by changing individual options, see Chapter 3.
For Hayes mode options, see also
Chapter 5
.
19
MODEM 32144
Table 2-1. Available Quick Setup Configurations.
Quick Setup as Identified on LCD Description
QUICK SETUP <1>2-Wire Dial Hayes Emulation Mode—
2-W DIAL (HAYES) This Quick Setup (for communication over ordinary phone lines) allows the modem to automatically dial (autodial) a previously stored phone number and respond to Hayes commands. This mode is compatible with communication software packages that use Hayes™ style “AT” commands. The Hayes mode Quick Setup is the factorydefault configuration for the modem.
QUICK SETUP <2>2-Wire Dial V.25 bis Mode,
V25 DIAL (Async) Asynchronous—In V.25 bis mode, the modem operates in conformance with CCITT recommendation V.25 bis, allowing you to store and direct dial or autodial phone numbers from the DTE. Use Quick Setup
2 if the DTE connected to the modem is asynchronous.
QUICK SETUP <3>2-Wire Dial V.25 bis Mode,
V25 DIAL (Syn_c) Synchronous, Character-
Oriented—Same as Quick Setup
2 except for data protocol. Use
Quick Setup 3 if the DTE is synchronous, character-oriented.
20
CHAPTER 2: Quick Start
Table 2-1. Available Quick Setup Configurations (continued).
Quick Setup as Identified on LCD Description
QUICK SETUP <4>2-Wire Dial V.25 bis Mode,
V25 DIAL (Syn-b) Synchronous, Bit-Oriented—Same as Quick Setup 2 except for data protocol. Use Quick Setup 4 if the
DTE is synchronous, bit-oriented.
QUICK SETUP <5>2-Wire Dial Dumb Mode—When the
2-W DIAL (DUMB) modem is in Dumb mode, you can use the modem for dial answer-only applications, dial a previously stored telephone number from the front panel, or dial phone numbers via an external source (telephone).
QUICK SETUP <6>2-Wire Leased Line Originate Mode—
2-W LEASED (ORG) In Leased Line mode, the modem connects to the leased line and stands ready to send and receive data. Use
Quick Setup 6 if the leased line is a
2-wire line and you want to configure the modem as the originate modem.
QUICK SETUP <7>2-Wire Leased Line Answer Mode—
2-W LEASED (ANS) Same as Quick Setup 6 except for modem answer/originate status. Use
Quick Setup 7 if the leased line is a
2-wire line and you want to configure the modem as the answer modem.
21
MODEM 32144
Table 2-1. Available Quick Setup Configurations (continued).
Quick Setup as Identified on LCD Description
QUICK SETUP <8>4-Wire Leased Line Originate Mode—
4-W LEASED (ORG) Same as Quick Setup 6 except for line type. Use Quick Setup 8 if the leased line is a 4-wire line and you want to configure the modem as the originate modem.
QUICK SETUP <9>4-Wire Leased Line Answer Mode—
4-W LEASED (ANS) Same as Quick Setup 6 except for line type and modem answer/originate status. Use Quick Setup 9 if the leased line is a 4-wire line and you want to configure the modem as the answer modem.
QUICK SETUP <10>V.33 Leased Line Operation—This
4-WLL V.33
Quick Setup configures the modem for V.33 operation.
QUICK SETUP <11>2-Wire Dial Bell 208 Operation—
2-W DIAL (208) This Quick Setup configures the modem for 2-wire dial operation compatible with Bell standard 208B.
QUICK SETUP <12>2-Wire Dial V.32/208 Auto-Detect
2-W DIAL V32/208 Mode—This Quick Setup configures the modem to automatically select
V.32 or Bell 208 operation, depending on the mode of the originating modem.
22
CHAPTER 2: Quick Start
Table 2-1. Available Quick Setup Configurations (continued).
Quick Setup as Identified on LCD Description
QUICK SETUP <13>4-Wire Leased Line V.29 Mode—
4-WLL V.29
This Quick Setup configures the modem for V.29 operation, for compatibility with V.29 modems.
QUICK SETUP <14>V.29 Fast Master Mode—
V.29 FAST MASTER This Quick Setup configures the modem for V.29 fast train master operation, for use in a multidrop network where multiple remote
(slave) modems share the master modem as the host modem.
QUICK SETUP <15>V.29 Fast Slave Mode—
V.29 FAST SLAVE This Quick Setup configures the modem for V.29 fast train slave operation, for use in a multidrop network where multiple remote (slave) modems share the same host
(master) modem.
23
MODEM 32144
Quick Setup
Table 2-2. Quick Setup Modes Supported.
V.32/19.2M
Hayes (01)
V.25bis (02-04)
Dumb (05)
Leased (06-09)
Y Y
V.33 (10)
Bell 208 (11-12)
N
N
Y
Y
V.29 (13-15) N Opt.
Y Yes; supported. N No; not supported.
Opt. Optional;
24
2.4 Basic Operation
To assist you in getting the modem up and running, the following sections provide basic information for each of the modem’s primary operating modes. For additional operating information, refer to the remaining chapters in this manual.
If you encounter difficulty, refer to Section 2.4 at the end of this chapter.
2.4.1 2-W
IRE
D
IAL
H
AYES
M
ODE
(Q
UICK
S
ETUP
1)
Two-wire dial Hayes emulation mode is the factory default configuration for the modem.
Hayes mode operation is explained in detail in Chapter 5.
To dial a telephone number in Hayes mode, type the Hayes command AT D on your computer or terminal keyboard followed by the number you want to call. For example:
AT D 5551212 [CR]
Dashes or spaces may be included for clarity, but they are not necessary. (The modem will ignore them.) A carriage return
[CR] or period is required at the end of each command line.
(On most keyboards, the carriagereturn [CR] key is labeled “Enter” or “Return.”) In response to the command line shown above, the modem will dial the number
555-1212.
CHAPTER 2: Quick Start
If you have to dial an access code such as 9 to dial out of your building, insert the access code and a comma in the dial string.
AT D 9,5551212 [CR]
The comma causes the modem to pause for 2 seconds. This allows the modem to detect a second dial tone (after the access code) before dialing the number.
The default dialing mode is pulse dialing. To change to tone dialing, insert a T after AT D: AT DT. To change from tone dialing to pulse dialing, insert a P: AT DP. The specified dialing mode will remain active until the alternate mode is specified or the modem is reset.
When a phone number is successfully dialed, a “CONNECT” message will appear on the computer screen, and the LCD on the modem will display a status screen that typically look like this:
D TR MR RS CS TD
9600 CD RD
25
MODEM 32144
TD and RD will be flashing (to indicate that the modem is transmitting and receiving data). (The speed may be other than 9600 bps; the modem will automatically adjust to the speed of the remote modem, provided the remote unit is a compatible modem.)
To terminate a call, first enter the escape sequence +++. When the
OK response appears on the DTE screen, enter the command AT H.
An alternate method is to drop the
DTR signal from the DTE. If you are using a computer with a communication software program, follow the program’s instructions for initiating and terminating calls.
2.4.2 2-W
IRE
D
IAL
V.25
BIS
M
ODE
(Q
UICK
S
ETUP
2–4)
The modem supports three types of
V.25 bis operation—asynchronous; synchronous, character-oriented; or synchronous, bit oriented. There is a Quick Setup for each V.25 bis type, as shown in Table 2-1. For
V.25 bis operation, the modem must be configured to use the same data protocol (asynchronous; synchronous, character-oriented; or synchronous, bit-oriented) as the attached DTE. If you have selected the correct V.25 bis Quick
Setup, the data protocol will be set automatically to the correct setting.
V.25 bis mode operation and commands are explained in detail in Chapter 6.
Asynchronous V.25 bis Operation
In asynchronous applications,
V.25bis commands (listed in
Chapter 6
) may be entered from the DTE keyboard. As an example, the simplest command sequence is
CRN 3331234
. In response to this command, the modem sends a VAL result code (indicating that the command has been accepted), dials the telephone number, 333-
1234, and then waits for an answer tone from a remote modem. If no carrier is detected within a given time (45 seconds by default), the modem automatically releases the line and sends a CFI NT result code.
Spaces entered in the command line for readability are ignored; therefore, CRN 555 1212 will have the same effect as CRN5551212.
The data format of the DTE should be set to 7 data bits with even parity and one stop bit. (Note that the default DTE interface rate is 38,400 bps in asynchronous mode.)
When a phone number is successfully dialed, the EIA status screen on the modem will typically look like this:
D
9600
TR MR RS CS
CD
26
CHAPTER 2: Quick Start
Synchronous V.25 bis Operation
In synchronous applications, the
V.25 bis commands can be used to facilitate computer-controlled operations. Synchronous bitoriented operation uses High-
Level Data Link Control (HDLC) formatting. In synchronous character-oriented operation, messages are framed by synchronous start-of-text and end-of-text characters, with the start-of-text character preceded by two synchronous (SY) characters.
2.4.3 2-W
IRE
D
IAL
D
UMB
M
ODE
(Q
UICK
S
ETUP
5)
Dumb mode is used primarily for manual call origination, and answer-only applications, and in conjunction with certain dial back security systems that use MI/MIC signals to place the modem on-line.
(If you need to configure the modem for MI/MIC use, refer to Appendix C.) For additional information on Dumb mode, refer to Chapter 4.
Answering a Call Automatically
After the Quick Setup for 2-wire dial Dumb mode has been selected, the modem is configured to automatically answer incoming calls. The only other requirement is that the DTE must provide the
DTR signal (TR on the EIA status screen) to the modem or DTR must be set to TRUE (using the modem’s DTR from EIA option screen).
Originating a Call from the Front
Panel
Before you can originate a call from the front panel, you must store the number to be dialed in the modem.
Storing a Number
From the EIA status screen, access the PHONE screen by pressing the following pushbuttons in sequence:
ENT
Right arrow
Pushbutton 1
Left arrow 2 times
Pushbutton 1
The abbreviations DEC, CTRL, and INC will be displayed on the bottom line of the LCD, indicating that you have located the PHONE screen.
Store the phone number as follows: Use the right and left arrow pushbuttons to go to the digit you want to change. The cursor will cause the character at that digit location to blink, indicating that the digit or character can be changed. Use pushbutton 1 to decrease numbers and pushbutton 3 to increase them.
Use pushbutton 2 (CTRL) to sequence through the dialing control characters (which are explained in Chapter 4). Use the arrow pushbuttons to move on to the next digit or character to be changed. (The characters that can
27
MODEM 32144
be stored are listed in Chapter 4.)
The phone number is saved when you return to the Main Menu. To return to the EIA status screen, press ENT three times.
Autodialing the Stored Number
To autodial the stored number from the EIA status screen, press the following pushbuttons in sequence:
ENT
Pushbutton 3 (to select DIAL from MAIN MENU screen 1)
Pushbutton 1 (to select DIAL from the AUTO-DIAL screen)
When the local modem has successfully established a connection with the remote unit, the EIA status screen should be present. Typically this screen will look like this:
D
9600
TR MR RS CS TD
CD RD
If the modem’s LCD displays an
AUTO-DIAL FAILURE message, refer to the explanations listed below.
Table 2-3. Failure Message and Explanations.
Failure Message
LINE OCCUPIED
Explanation
The data line is already in use.
DIAL NOT ALLOWED
NO DTR
NO LINE CURR
Modem is not configured for dial backup.
DTR is not present.
Line current has been lost.
28
CHAPTER 2: Quick Start
Terminating a Data Call
Normal termination of a data call is processed through communication software. An alternate method is to switch to the HANGUP option on the AUTO-DIAL screen. Another method is to drop the DTR signal from the DTE (by software control or by turning the DTE off).
For manual originate/answer operation, see Chapter 4.
2.5 Leased Line (2- or 4-Wire) Mode
(Quick Setup 6–9)
This section does not apply to V.33
leased-line operation. For V.33
leased-line operation, see the next section.
The following information applies to both 2-wire and 4-wire leased line operation:
• The modem must be configured for the correct line type—2-wire or 4-wire. If you have selected the correct
Leased Line Quick Setup, the line type will be set automatically to the correct setting.
• One modem must be set to originate mode and the other to answer mode. If you have selected the correct Leased
Line Quick Setup, the answer/originate status will be set automatically to the correct setting.
• Leased line operation is restricted to data rates of
4800 bps or higher.
• Lines can be conditioned or unconditioned.
Four different leased-line Quick
Setups are available (not counting
V.33 leased line operation), as shown in Table 2-1. After you select the appropriate leased-line Quick
Setup, the answer unit immediately generates an answer tone that signals the originate modem to begin the training sequence, meaning it is ready to “handshake” with the originate modem.
When the local modem has established a connection with the remote unit, the EIA status screen should be present. Typically this screen will look like this:
TR MR
9600
RS CS
CD
TD
RD
2.6 V.33 Leased Line Operation (Quick
Setup 10)
V.33 operation is available on the modem and is restricted to speeds of 12,000 and 14,400 bps.
V.33 leased line operation provides compatibility with V.33
modems (synchronous operation only).
29
MODEM 32144
A 4-wire line must be used
(conditioned or unconditioned), and both connected modems must be set for V.33 operation.
After the V.33 Leased Line
Quick Setup has been selected, the modem immediately begins the training sequence, meaning it is ready to communicate with the other modem. The second modem to come online will automatically establish the data link (regardless of whether it is the local or remote unit).
When the local modem has successfully established a connection with the remote unit, the EIA status screen should be present. Typically the screen will look like this:
2.7 2-Wire Dial Bell 208 Operation
(Quick Setup 11–12)
The modem supports Bell 208 operation. To confirm this, select
SETUP from MAIN MENU screen
2. Then select QUICK from SETUP screen 1. Press the right arrow pushbutton repeatedly to cycle through the Quick Setup screens. If you can access the two Quick Setup screens shown below, the unit supports Bell 208 operation.
TR MR
14.4
RS CS
CD
TD
RD
Three options are intended for
V.33 (and Bell 208A/B) operation exclusively. These options are listed in Chapter 3 under the heading
V.33 and Bell 208A/B Options.
30
CHAPTER 2: Quick Start
QUICK SETUP
2-W DIAL (208)
<10>
QUICK SETUP
2-W DIAL V32/208
<11>
Fig. 2-3. Quick Setup.
2.8 Two Types of Bell 208 Operation
Two Bell 208 Quick Setups are available, as shown in Table 2-1.
One configures the modem for
Bell 208 operation, exclusively; the other configures the modem for V.32/208 auto-detect mode.
2.8.1 B
ELL
208 O
PERATION
(E
XCLUSIVE
)
The Quick Setup identified on the
LCD as 2-W DIAL (208) configures the modem for 2-wire dial synchronous operation compatible with Bell standard 208B. The data rate is fixed at 4800 bps, and the data format is set to synchronous.
Both connected modems must be set for 208B operation.
Beginning with the section titled
“Answering a Call Automatically,” all information in Section 2.4.3 also applies to Bell 208 operation.
31
MODEM 32144
2.8.2 V.32/208 A
UTO
-S
ELECT
M
ODE
The Quick Setup identified on the
LCD as 2-W DIAL V32/208 (shown above) configures the modem for
V.32/208 auto-detect mode. This means the modem will automatically select V.32 or Bell 208 mode, depending on the mode of the originating modem. Note that the modem will not handshake in V.22
bis, Bell 212/103, or V.21/V.22/
V.23 mode when it is configured for V.32/208 auto-detect mode.
2.9 4-Wire Leased Line V.29 Mode
(Quick Setup 13)
The following information applies to 4-wire leased line V.29 operation:
• The modem must be configured for use with a 4-wire line. If you have selected the
4-Wire Leased Line V.29 Quick
Setup, the line type will be set automatically to the correct setting.
• Operation is restricted to data rates of 4800, 7200, and 9600 bps.
• Lines can be conditioned or unconditioned.
After you select the 4-Wire
Leased Line V.29 Quick Setup, the modem will send a training sequence and wait for a training response from the remote modem.
The modem will repeat the training sequence every 1.2 seconds until the remote modem responds.
When the local modem has established a connection with the remote unit, the TIA/EIA status screen will be present. Typically, this screen will look like this:
TR MR RS CS TD
9600 CD RD
NOTE
For point-to-point 4-wire leased line V.29 operation, the Auto-Retrain option should be enabled on both modems. (Auto-Retrain is enabled by default if you select the 4-Wire Leased
Line V.29 Quick Setup.) If the Auto-Retrain option is disabled, the modem will not transmit a training sequence and will instead train on the data stream from the remote modem. Disabling Auto-
Retrain in 4-wire leased line
V.29 mode is recommended for test purposes only. If
Auto-Retrain is disabled, it should be disabled on both modems.
32
2.9.1 V.32 D
IAL
B
ACKUP
NOTE
Dial backup can only be used in point-to-point applications.
To prevent service interruption in case of poor leased line conditions, the modem can be configured for V.29 leased line operation with V.32 dial backup.
This means that the modem will use dial lines to automatically restore operation when conditions on the leased lines deteriorate.
(The modem will use V.32
modulation for dial backup.) To set up the modem for V.29 leased line operation with dial backup, follow these steps:
1. Select the 4-wire leased line
V.29 (4-WLL V.29) Quick Setup on both the local and remote modem.
2. One modem must be set to originate mode and the other to answer mode. To make this selection, use the ANS/ORG
DEFAULT screen on the front panel LCD.
3. Configure the modems for leased line auto-recovery, as explained in Chapter 4.
CHAPTER 2: Quick Start
2.10 V.29 Fast Master and Slave
Modes (Quick Setups 14–15)
NOTE
Modems used in a V.29 Fast
Master and Slave (multidrop) configuration must be modems that support V.29 operation.
In multidrop operation (Figure
2-4
), the master modem transmits to all of the slave (remote) modems.
When the DTE at a slave site recognizes its own address in the polling protocol, it raises RTS to the slave transmitter. The slave responds by transmitting a special training sequence, then raising
CTS and transmitting the data from the DTE. When the DTE has completed transmission, it lowers
RTS and the modem will drop carrier to let the next modem on the poll list use the channel.
33
MODEM 32144
Fig. 2-4. A Typical Multidrop Configuration.
The V.29 Fast Master and Fast
Slave modes support sync data rates of 4800, 7200, and 9600 bps and an async data rate of 9600 bps only.
The leased lines can be conditioned or unconditioned. The master modem must be set to originate mode, and the slave modem must be set to answer mode.
(The Answer/Originate option is automatically set to these settings when the V.29 Fast Master and Fast
Slave Quick Setups are used.)
NOTE
If you’re using V.29
master/slave async in an unmanned location, call
Black Box Tech Support at
724-746-5500.
S
LAVE
-
TO
-M
ASTER
(I
NBOUND
)
T
RANSMISSION
When the remote modems come on-line, they automatically synchronize to the incoming carrier and train on the data stream from the master modem. Slave-to-master transmission is always switched carrier operation under control of the RTS signal from the DTE.
An anti-streaming timer built into the modem will (if enabled) halt transmission if the DTE holds RTS on for more than 30 seconds. The assumption is that if RTS is held on for more than 30 seconds, there is a fault in the DTE.
NOTE
See page 176 (pump 3) to enable anti-streaming.
34
If you access the TIA/EIA status screen on the LCD display when a slave modem is transmitting to the master modem, the status screen will typically look like this:
TR MR RS CS TD
9600 CD RD
Typically, TD, CD, and RD will flash on the master modem, and
RS, CS, TD, and RD will flash on the slave modem.
CHAPTER 2: Quick Start
2.11 If You Have Problems
If you encounter difficulties in setting up or using the modem, try the remedies described below. If you suspect a system malfunction, follow the diagnostic procedures described in Chapter 7. If you cannot resolve the problem, call
Technical Support.
2.11.1 A
LL
M
ODES
Make sure all cables are properly connected to the back of the modem.
2.11.2 A
LL
D
IAL
M
ODES
(H
AYES
, V.25
BIS
, D
UMB
, B
ELL
208,
AND
V.32/208)
DTR (Data Terminal Ready) must be ON (received from DTE, or
DTR from EIA option set to TRUE) if you want to use the modem’s autodial or auto-answer features.
(If DTR is ON, the TR indicator will be present on the EIA status screen.
35
MODEM 32144
2.11.3 A
LL
A
SYNCHRONOUS
M
ODES
The modem’s default DTE speed is
38,400 bps in asynchronous mode.
If the local DTE does not support this speed, change the modem’s
DTE Speed option setting. In
Hayes mode, the default DTE speed is automatically overridden when the modem is autobauded
(when the Hayes mode “AT” attention code is sent to the modem).
2.11.4 H
AYES
M
ODE
In Hayes mode, with default settings in effect, the modem transmits result codes (messages) to the DTE. In some installations, this may cause undesirable interaction with the attached DTE.
If such interaction occurs, result codes for incoming calls should be suppressed (using the command
AT Q2
).
36
CHAPTER 2: Quick Start
2.11.5 A
LL
L
EASED
-L
INE
M
ODES
(2-W
IRE
, 4-W
IRE
, V.33,
AND
V.29)
DTR (Data Terminal Ready) must be ON for the units to train on the leased line. (If DTR is ON, the TR indicator will be present on the EIA status screen.)
If the signal quality appears to be inadequate (see Section 7.6.2) or if the modems are frequently retraining, try changing the equalization option.
2.11.6 L
EASED
L
INE
(E
XCLUDING
V.33
AND
V.29 O
PERATION
)
Make sure one modem has been set to originate mode and that the other has been set to answer mode.
(If the correct Quick Setup has been selected, and not incorrectly modified, the answer/originate status should be correct.)
37
MODEM 32144
3. Options: Customizing the Modem
Setup
3.1 Methods for Selecting Options
The modem allows you to easily select options in order to tailor the modem’s operation to suit a particular application. Options can be selected in any of the following ways:
• Quick Setup. This is the easiest way to set up the modem.
Quick Setup (explained in
Chapter 2
) automatically sets all options according to a preset configuration.
• Front-panel option selection.
This is the easiest and most commonly used method for selecting individual option choices. Typically you would select an overall configuration via Quick Setup and then modify it to suit your application by changing selected options from the front panel. Changes are made by accessing individual option screens on the front panel LCD and then making selections using the control pushbuttons.
(An alternate way to change options from the front panel is to use the modem’s Summary
Setup feature, which is described below.)
• Summary Setup. This is the fastest way to selectively change multiple options. All options are accessed using just a few of the LCD screens. However, because these screens show numerical codes with very little explanation, Summary Setup is recommended only for experienced users. Summary
Setup is explained in Appendix
B
.
3.2 Front-Panel Options
This chapter describes the standard instead of selecting options from the front panel. An alternate method for selecting options from the front panel (Summary Setup) is explained in Appendix B.
3.2.1 P
USHBUTTONS AND THE
LCD
Options are selected from the front panel by pressing the front panel pushbuttons (Fig. 3-1). The possible choices for each option are shown on the liquid-crystal display (LCD).
38
CHAPTER 3: Options: Customizing the Modem Setup
DISPLAYS PREVIOUS
MENU SCREEN
DISPLAYS NEXT
MENU SCREEN
EXITS FROM
DISPLAYED
SCREEN
1 2 3 ENT
USED TO SELECT CHOICE 1, 2 OR 3 FROM THE LCD
(Each of the possible selections on the bottom line of the LCD is identified as 1, 2 or 3 below the LCD.)
Fig. 3-1. Summary of Pushbutton Control Functions.
Arrow Pushbuttons
The left arrow (<--) and right arrow
(-->) pushbuttons are used to display additional or previous screens that are part of the same menu. The right arrow pushbutton displays an additional menu screen
(if there is one); the left arrow pushbutton displays the previous menu screen. With respect to how the LCD flow chart is set up, the arrow pushbuttons “move you” either right or left within the chart.
If a menu has more than one screen, each screen is numbered.
The screen number is shown in the upper right corner of a screen (see the sample screen below.) If a menu has no screen number, it has only one screen. Additional menu screens (where present) show additional option selections.
MAIN MENU <2>
SETUP TEST RMT
39
MODEM 32144
Numbered Pushbuttons
Pushbuttons 1, 2, and 3 correspond to segments 1, 2, and 3 of the LCD screen. These segments (left, middle and right positions of the
LCD screen) are numbered on the modem’s front panel. To make a selection from a menu screen, simply push the button with the same number as the selection you want.
With respect to how the LCD flow chart is organized, pushbuttons 1, 2, and 3 will either take you to a lower level—or, where there is no route to a lower level, they will select an option.
ENT Pushbutton
To exit from a displayed screen, press the ENT (enter) pushbutton.
With respect to how the LCD flow chart is set up, pushing the ENT button will move you upward through the chart (toward the
MAIN MENU). If you become lost, pressing the ENT button repeatedly will return you to screen
1 of the MAIN MENU. Pressing
ENT repeatedly after you have arrived at MAIN MENU screen 1 will cause the LCD to alternate between the EIA status screen and the MAIN MENU. (In the case of most tests, the ENT button cannot be used to exit the test screen once the test has been activated; you must first press the ENT button and then select OFF to end the test.)
3.3 Selecting Options from the Front
Panel
This section applies to all option screens on the front panel LCD except the Summary Setup screens, which are explained in Appendix B.
Options are accessed from the
SETUP menu. As shown in the
LCD flow chart, the SETUP menu consists of six screens and is accessed from screen 2 of the
MAIN MENU. (With screen 2 of the MAIN MENU displayed, push button 1 to select SETUP.)
Once you have located the screen that displays the option you want to access or change, select your choice by pushing the button with the same number as the selection you want. Each selection on the bottom line of the LCD is numbered either
1, 2, or 3 on the modem’s front panel (not on the LCD), as shown in Fig. 3-2.
40
CHAPTER 3: Options: Customizing the Modem Setup
SETUP
< 1 >
QUICK LINE SPEED
1 2 3
LCD
Front panel
Fig. 3-2. The Front Panel.
When an option is first selected, it will flash on and off on the LCD.
However, it will not take effect until you leave the SETUP menu. Simply accessing an option screen will not change the option, so do not be afraid to experiment with the LCD and pushbuttons.
Note the following important points—
• Selected options do not become active until you leave the
SETUP menu.
• Changing some options will cause the modem to automatically reset.
• The option choices you select are automatically saved by the modem when you leave the
SETUP menu.
3.3.1 DEC/INC
(D
ECREASE
/I
NCREASE
) S
CREENS
Several option screens show the abbreviations DEC and INC on the bottom line of the LCD display.
This means that the numerical value shown on the top line (e.g., a stored phone number) can be changed. Selecting DEC
(pushbutton 1) will decrease the value; selecting INC (pushbutton
3) will increase it.
41
MODEM 32144
3.3.2 E
XAMPLE OF
H
OW TO
S
ELECT AN
O
PTION
The example that follows illustrates how options are selected. As you follow the steps below, refer to the
LCD flow chart (SETUP OPTIONS side). When you are done, you can easily restore default settings for the type of application you will be using by selecting the appropriate
Quick Setup (Table 3-1).
The example shows how to change the volume of the modem’s speaker from LOW or HIGH (the default setting) to MEDIUM. To makes this adjustment, you must locate the SPEAKER VOLUME screen on the LCD. To reach this screen, you must first access MAIN
MENU screen 2, then SETUP screen 4 and then MODEM
SETUPS screen 5, as explained below:
After powering on the modem, press ENT to get the first screen of the MAIN MENU. Press the right arrow pushbutton (—>) to go to screen 2 of the MAIN MENU (so the SETUP menu can be selected):
Press pushbutton 1 to access the first page of the SETUP menu:
SETUP
QUICK LINE SPEED
<1>
Now press the right arrow pushbutton three times; this will cause SETUP screen 4 to be displayed:
SETUP
TEST EIA MODEM
Press pushbutton 3 to select
MODEM (for MODEM SETUPS).
The first MODEM SETUPS screen will be displayed:
MODEM SETUPS
CDLVL
<4>
<1>
TXLVL
Press the right arrow pushbutton four times to reach MODEM
SETUPS screen 5:
MAIN MENU
SETUP
<2>
TEST RMT
MODEM SETUPS <5>
FP SPK SPKVOL
42
CHAPTER 3: Options: Customizing the Modem Setup
Press pushbutton 3 to select
SPKVOL (speaker volume). The
SPEAKER VOLUME screen will be displayed:
SPEAKER VOLUME
LOW MEDIUM HIGH
The currently selected setting will be flashing on and off. Press pushbutton 2 to switch the volume setting to MEDIUM. “MEDIUM” will begin to flash on and off, indicating that this setting has been selected (although the new selection will not become active until you exit the SETUP menu).
To return to the first screen of the MAIN MENU, press the ENT button several times.
3.3.3 H
OW TO
R
ETURN TO THE
EIA
S
TATUS
S
CREEN
Once your selection is complete, you will most likely want to return to the EIA status screen. Do this by pressing the ENT pushbutton several times—exactly how many times will depend on which screen you are exiting from. (If the modem is in a test mode, you must in most cases press ENT and then select
OFF, which will end the test, before the ENT button can be used to exit the test screen.)
3.3.4 A
UTOMATIC
C
ONFIGURATION
S
AVE
F
EATURE
When you exit the SETUP menu, the modem automatically saves its current configuration (i.e., option setups, including any changes you have selected) to its internal memory. The saved configuration will remain in effect until it is changed—even if the modem loses power.
3.3.5 H
OW TO
R
ETURN TO
D
EFAULT
S
ETTINGS
The factory default settings are different for each of the Quick
Setup configurations available to the modem [2-wire dial Hayes, 2wire dial V.25 bis, etc.]. To return to the factory-default settings for any of these configurations (except
2-wire dial Hayes), go to the
QUICK SETUP menu and select the desired configuration.
The 2-wire dial Hayes Quick
Setup does not recall the factorydefault setting, it recalls the stored user profile 0 or 1, depending on which has been designated as the default; see &Y command.
To entirely reconfigure the modem to the state it was in when shipped from the factory, hold in the right arrow pushbutton as you power up the modem until the words “FACTORY DEFAULT” appear on the LCD.
43
MODEM 32144
3.4 Options
The rest of this chapter describes the options available from the modem front panel. The options are presented in the same order in which they appear in the LCD flow chart (which is shipped with the modem). For each option, all possible choices (available selections) are explained.
The line below each option heading indicates the applicability of the option: A mode (like Quick
Setup mode) is listed only if the option is effective in that mode and if it can be of practical use in that mode.
For a concise summary of the modem options and option choices, see the LCD flow chart.
The default settings for each option are listed in Appendixes A and B.
Quick Setups
All modes
The Quick Setups (one for each operating mode) are unique in that they affect the entire modem configuration. See Chapter 2 and
Appendix A
.
Line Type
All modes
2W-D. This selection (2-wire dial line) is used for dialup applications.
2W-LL. This selection (2-wire leased line) is used for leased line applications that use 2-wire lines.
4W-LL. This selection (4-wire leased line) is for leased line applications that use 4-wire lines.
3.5 Speed (Data Rate) Options
Speed Limit
All modes
The Speed Limit option allows you to set a minimum and/or maximum data rate. The modem will automatically operate at the highest possible data rate within the limits selected, as indicated in
Table 3-1
. (In Hayes mode, the maximum rate of the originate modem is determined by the originate modem’s DTE autobaud rate. See Table 3-1.)
EIA-23. This choice is available for setting the maximum rate only. If
EIA-23 is selected, the rate will be set at either 9600 or 4800 bps, depending on the condition of pin
23 on the EIA interface: Pin 23 high (greater than or equal to +3 volts) = 9600 bps; pin 23 low (less than or equal to –3 volts) = 4800 bps.
44
CHAPTER 3: Options: Customizing the Modem Setup
Table 3-1. Effect of Speed Limit Settings on Data Rate.
Max rate setting, bps
14,400 1
19,200
12,000 1
9600
7200 2
4800
300 to 2400
EIA-CTRL
Dialer option
xx xx xx xx
Leased line modes xx xx xx xx
Resultant data rate, bps
14,400 1
19,200
12,000 1
9600
7200 2
4800
2400
9600 or 4800 3
300 to 19,200
EIA-CTRL
Dial modes—Answering xx xx
Negotiated between min.
and max. setting
9600 or 4800 3
300 to 19,200
EIA-CTRL xx
Dial modes—Originating
OFF or DTR
OFF or DTR
HAYES 4
Negotiated between min.
and max. setting
9600 or 4800 3
Negotiated between autobaud speed and minimum setting on originate modem 4 xx Does not matter—setting does not affect data rate.
1 Both 14,000 and 12,000 bps rates are available for the modem.
2 7200 bps is available only if V.32bis mode is enabled (via Summary Setup,
V.32 Mode option).
3 9600 bps if EIA pin 23 is high, 4800 bps if pin 23 is low.
4 If SYNC AFTER DIAL is enabled (using the &Q1 command), the rate will be negotiated between the autobaud speed and 1200 bps.
45
MODEM 32144
Speed Matching
If speed conversion is not desired, the DTE interface rate should be set to follow the rate at which the modem connected (i.e., DTE rate =
DCE rate, or speed matching).
Change the Speed matching parameter shown in the diagram to 1 (enable).
NOTE
Speed matching is only effective for dial applications and will only function if error correction or buffer mode is enabled.
Speed Type
All modes
The V.32 master handshake normally used by the modem is incompatible with the CCITT V.33
and Bell 208 handshakes. However, the modem (only) can be configured for either V.33 or Bell
208 compatibility, and for Bell 208 operation. (To determine if a modem supports Bell 208 operation, see Section 2.7.)
V.33 or Bell 208 speed types can be set independently of other options via the SPEED TYPE screen; however, to ensure proper operation, it is recommended that you use the V.33, Bell 208, or V.32/208 Quick Setup configuration, as explained in
Chapter 2
.
The available speed-type selections are listed below. Use pushbuttons 1 (DEC) and 3 (INC) to cycle through the speed-type selections. The currently selected speed type is displayed in the
SPEED TYPE screen (upper right corner), as shown in Fig. 3-3.
46
CHAPTER 3: Options: Customizing the Modem Setup
SPEED TYPE
DEC
V.32
INC
Fig. 3-3. Current Speed Type Selection.
V.32
. The modem normally uses the V.32 handshake. (The modem also uses this handshake for
V.32/14.4 Kbps operation.)
V.33 operation is available on the modem for 4-wire leased-line synchronous operation only. The available data rates are 14.4 and
12.0 Kbps. Either of these rates may be set as the maximum or minimum by using the Speed Limit
MAXIMUM RATE and MINIMUM
RATE screens.
Both connected modems must be set for V.33 leased line operation.
208
. This selection (available only on models that support Bell 208 operation) provides Bell 208A compatibility for 2-wire or 4-wire leased line operation and Bell 208B compatibility for 2-wire dial operation. Operation is full duplex in 4-wire leased line mode only. In
Bell 208B mode, synchronous V.25
bis autodialing is available, but
Hayes operation is not. Calls may be originated from the front panel.
The data rate is fixed at 4800 bps for 208A/B operation, and the data format is synchronous only.
Both connected modems must be set for 208A/B operation. For
2-wire applications, the carrier option must be set for switched carrier operation (SWITCH) via the CARRIER screen, and CTS must be set to follow RTS (CTS to EIA option).
V.29.
This selection is available only on models that include the
V.29/V.27/V.26 option. It configures the modem for V.29
operation (for data rates of 9600,
7200, or 4800 bps). To select a specific data rate, use the Speed
Limit option to select 9600, 7200, or 4800 bps (only) as the minimum and/or maximum data rate (DCE
RATE). In V.29 mode, the modem does not support automatic rate adjustment (fallback) or error correction.
47
MODEM 32144
AUTO. This selection configures the modem for V.32/208 auto-detect mode. This mode allows the modem to automatically select V.32 or Bell
208 operation, depending on the mode of the originating modem.
Note—
• To enable V.32/208 auto-detect mode, the Speed Type option must be set to AUTO and the
V.32/208 auto-detect Summary
Setup option must be set to 1 for enable. This option is shown in Appendix B, Fig. B-6.
• Selecting the V.32/208 Quick
Setup automatically sets the speed type to AUTO—and enables the Summary Setup auto-detect option (sets it to 1).
• When the speed type is set to
AUTO, the ALX will not handshake in V.22 bis, Bell
212/103 or V.21/V.22,V.23
mode.
• All information in the 208 section above applies to
V.32/208 auto-detect mode.
Three options intended only for
208A/B and V.33 operation are accessible through MODEM
SETUPS screen 7. These options allow you to select constant or switched carrier, set CTS to follow
RTS or set CTS to be always on, or specify an RTS-CTS delay time.
For further information, see the
Carrier, CTS, and RTS-CTS Delay headings later in this chapter.
For further information on Bell
208 mode, see chapter (section titled Dumb Mode and Bell 208
Operation).
3.6 V.42 Error Correction Options
The modem supports both
CCITT V.42 error correction and
Microcom Networking Protocol
(MNP) error correction (classes 1 through 5). V.42 and MNP both provide end-to-end error correction through an automatic repeat-transmission request algorithm. Both types of error correction enable the modem to detect data-transmission errors and automatically request retransmission of adversely affected data until it is received correctly.
Either error-correction standard
(V.42 or MNP) may be enabled for either dial or leased-line operation.
However, error correction can function only if all of the following conditions are present:
• The modem that the modem is communicating with must be equipped with the same type of error correction (V.42/V.42 bis or MNP).
• The same type of error correction (V.42/V.42 bis or
MNP) must be enabled at both ends of the communication link.
• Both communicating modems must be configured for asynchronous data format.
48
CHAPTER 3: Options: Customizing the Modem Setup
• The connected systems must support data flow control
(have buffering capabilities).
Note—
• The V.42 and MNP errorcorrection options (listed and described below) are effective only when all of the conditions listed above are present.
• Error-correction options cannot be changed when the modem is on-line.
• For valid test results, disable error correction before running diagnostic tests.
User-selectable options let you configure the modem for V.42
(LAPM) error correction only,
MNP error correction only, or V.42
error correction with MNP as the fallback (alternate) error correction protocol. Data compression may also be enabled by selecting either V.42 bis or MNP class 5 error correction. Other error-correction options are also available.
The available error-correction options are V.42 Mode, MNP Class
(class limit), Break Handling, V.42
Selection, Buffer Mode/Speed
Conversion, DTE Speed, DTE-DCE and DCE-DTE Flow Control options, and Pass-through Flow
Control. All of these options affect the type of error correction selected via the V42 SELECTION screen (discussed below), except that the MNP Class option is applicable only to MNP operation.
The error correction options can be selected in any order, but the following sequence is suggested:
First select the type of error correction desired from the V.42
SELECTION screen. Next make a selection from the V.42 MODE screen. Then select other error correction options as appropriate for your application.
Two additional error-correction options are described near the end of this chapter, in Section 3.16,
Options Accessible Only via
Summary Setup
. These additional options are Selective
Retransmission and DCE Passthrough Flow Control.
V.42 Mode
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
The V.42 Mode settings described below apply to the type of error correction selected via the V42
SELECTION screen. For example, if LAPM ONLY has been selected as the error correction protocol, and MANDATORY is selected from the V42 MODE screen, V.42 or V.42
bis error correction will be activated—or if it cannot be, the modem will hang up.
49
MODEM 32144
OFF. Error correction will be disabled.
MANDATORY. Error correction will be activated. If the modem cannot establish a connection using the type of error correction selected via the V.42 Selection option, it will hang up.
TIGHT FIT = AUTO. The modem will fall back to buffer or non-buffer mode if conditions do not allow it to establish a connection using the type of error correction selected via the V42 SELECTION screen.
MNP Class (Limit)
Hayes, V.25bis, Dumb, Leased Line modes (except V.33)
This option is effective only when
MNP error correction is active. It limits MNP operation to the selected MNP class or lower.
(MNP classes 1-5 are available.)
In general, the higher MNP classes provide greater throughput. Class
5, the default, can provide as much as 2-to-1 data compression over the transmission link.
V.42 Selection Options
The following two options are available through the V.42
SELECTION screen:
Protocol
Hayes, V.25 bis, Dumb, Leased line modes (except V.33)
LAPM/MNP. The modem will attempt to establish a connection using the V.42 link access protocol for modems (LAPM). This is the primary error correction protocol under the CCITT V.42 standard.
If such a connection cannot be established (because the other modem does not support LAPM or is not configured for LAPM), the modem attempts to establish a connection using MNP class 5 as the fallback (alternate) errorcorrection protocol.
NOTE
When operating in LAPM mode, the modem uses V.42
error correction unless V.42
bis is enabled via the V.42
bis option. (V.42 and V.42bis
error correction both use
LAPM.)
LAPM ONLY. The modem will only attempt to establish an LAPM connection (will use only V.42 or
V.42 bis error correction).
MNP ONLY. The modem will only attempt to establish an MNP connection.
50
NOTE
If a connection cannot be established using the selected protocol LAPM/MNP,
LAPM ONLY or MNP ONLY), the action the modem will take depends on the V.42
mode setting. See V.42
MODE.
V.42 bis Operation
Hayes, V.25 bis, Dumb, Leased line modes (except V.33)
V.42 bis operation provides error correction with data compression.
Like V.42 error correction, V.42 bis uses the link access protocol for modems (LAPM). V.42 bis operation may be enabled or disabled.
Break Handling
Hayes, V.25 bis (Async only),
Dumb, Leased line modes (except
V.33)
When error correction is active, a break signal is relayed with an
“attention” packet. The break handling option determines how the attention packet is sent.
NONE. No attention packet is sent.
DESTRUCTIVE/EXPEDITED
(DESTR/EXP). All data in the buffer is deleted; the attention packet is then passed through the channel.
CHAPTER 3: Options: Customizing the Modem Setup
NON-DESTRUCTIVE/
EXPEDITED (NDT/EXP). The attention packet is passed through immediately, but data in the buffer is not deleted.
NON-DESTRUCTIVE/NON-
EXPEDITED (NDT/NEXP). The attention packet is passed through the channel in sequence, and any data is buffered; this preserves the sequence of data and breaks received.
Buffer Mode/Speed Conversion
Hayes, V.25 bis, Dumb, Leased line modes (except V.33)
This option enables or disables speed conversion (for asynchronous operation only) between the DTE and modem when error correction is not used.
ENABLE. When error correction is not active, the V.42 circuit will function as a buffer between the
DTE and the modem and will provide transmission-speed conversion.
DISABLE. Speed conversion is not allowed.
DTE Speed
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
51
MODEM 32144
This option controls the DTE speed; however, it is effective only when the modem is operating in
V.42 mode, MNP mode or buffer mode. (If the modem is not in one of these modes, the DTE speed will be the same as the connect rate.)
The DTE speed can be set for
38.4, 19.2, or 115.2 Kbps or 9600,
4800, 2400, 1800, 1200, 600, 300, or 110 bps (except that 1800 bps is not available if the modem is in Hayes mode). The default
DTE speed is 38.4 Kbps.
DTE speed refers to the speed of data transfer between the DTE and the local modem—it is not necessarily the same as the data transmission speed between the connected modems. If flow control is disabled, the DTE speed must be equal to or less than the modem speed, and the local and remote
DTE speeds must be equal.
For Hayes mode operation, this option sets the default DTE speed that will be effective after powerup or after a full modem reset.
However, the default DTE speed is automatically overridden when the modem is autobauded (when an
“AT” attention code is sent to the modem).
Flow Control
The flow control options control the data flow according to the availability of memory in the buffer. Flow control can be set independently for the terminal to the modem (DTE-DCE) and for the modem to the terminal (DCE-
DTE). The flow control options include DTE-DCE, DCE-DTE and
Pass-through Flow Control.
Note the following:
• Flow control only applies to asynchronous connections with
V.42 error correction or buffer mode enabled.
• When flow control is disabled, the DTE data rate must be equal to or less than the modem data rate, and the local and remote DTE data rates must be equal. (This precludes the need for flow control— which some DTE devices cannot handle—and avoids buffer overflow.)
• For DTE-DCE and DCE-DTE
Flow Control options: When
RTS on/off or CTS on/off flow control is used and a buffer connection has been established, conditions that will stop the data flow (e.g., dropped RTS) should not be permitted for long periods, if possible, to reduce the possibility of buffer overflow.
52
CHAPTER 3: Options: Customizing the Modem Setup
Fig. 3-4
illustrates the available flowcontrol options.
DTE
TD
DTE pass-through
RD pass-through flow control
Rx link flow control
Modem
Rx link flow control
DCE pass-through flow control
RD
DTE
Tx link flow control
DTE pass-through flow control
TD
Modem
Fig. 3-4. Flow-Control Options.
DTE-DCE Flow Control
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
NONE. This setting disables flow control. All flow-control characters are passed through the communication channel.
RTS on/off. The Request to Send signal controls data flow from the modem to the DTE. (RTS on/off is also called hardware, physical or out-band flow control.) This selection enables flow control for the local modem only.
53
MODEM 32144
DC1/DC2. This option inserts the control characters ^R and ^Q into the data stream to stop and start/restart the flow of data from a device. (DC1/DC2 is also called software, logical, or in-band flow control.)
DC1/DC3 (X-ON/X-OFF). This is the most common method of flow control. It inserts the control characters ^S and ^Q into the data stream to stop (^S) and start/ restart (^Q) the flow of data.
(DC1/DC3 is also called software, logical, or in-band flow control.)
NOTE
When using the modem for binary file transfer, in-band flow control (flow control using control characters) must be disabled. In this case, use hardware flow control or, as an alternative, lower the DTE speed to reduce the possibility of overflow.
DCE-DTE Flow Control
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
All information given above under DTE-DCE Flow Control also applies to the DCE-DTE (modem to terminal) flow control option, except that the CTS, Clear to Send signal, is used to control DTE-DCE data flow.
DTE Pass-through Flow Control
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
Pass-through Flow Control affects
DTE-DCE flow control only. This option determines whether flowcontrol characters received from the local DTE will be passed to the remote modem (if control characters are used for flow control).
ENABLE. Flow control characters are passed to the remote end of the communication connection after the modem acts upon them.
DISABLE. Flow control characters are not passed.
3.7 Address
All modes
The address screen allows you to set the address of the modem at your location. An address may be useful if the modem will be used in a rack enclosure or in a network environment.
The available address numbers are 000,000 through 999,999. On the ADDRESS screen, the three digits to the right of the comma are the unit address number. The three digits to the left are the group address number. To change the address, use the right and left arrow pushbuttons to go to the
54
CHAPTER 3: Options: Customizing the Modem Setup
digit you want to change. Then use pushbutton 1 to decrease (DEC) a number and pushbutton 3 to increase (INC) it. The default address is 999,999.
3.8 Dialer Mode
Several dialer mode options can be selected from the DIALER and DIAL V25bis screens.
Dialer
All modes
See also V.25 bis Dialer Modes below.
OFF. The autodialer is off, meaning the modem will operate in Dumb mode only. Calls must be made using the front panel AUTO-
DIAL function or they must be manually originated.
HAYES. The autodialer will automatically dial previously stored phone numbers, and the modem will respond to Hayes commands.
DTR. This selection enables DTR dialing, an option that allows you to set up the modem to automatically dial a stored number even when the autodialer has not been enabled.
NOTE
DTR dialing for V.25 bis mode or Penril autodialer mode cannot be enabled through the DIALER screen.
To select DTR dialing for
V.25bis or Penril mode, you must use the Penril/V.25bis
DTR Dialing option.
V.25 bis Dialer Modes
V.25 bis mode
Any of the selections from the
DIAL V25 bis screen will enable the V.25 bis autodialer.
The three selections on the DIAL
V25bis screen allow you to select a data protocol that is appropriate for the DTE the modem is connected to. The choices are—
ASYNCHRONOUS (Asyn)
SYNCHRONOUS, CHARACTER
ORIENTED (Syn_c), and
SYNCHRONOUS, BIT ORIENTED
(Syn_b)
3.9 Auto-Answer Option
Auto-Answer
Hayes, V.25 bis, Dumb, 208,
V.32/208 modes
This option determines whether or not a call is automatically answered when the phone rings.
55
MODEM 32144
Setting the Auto-Answer option to ENABLE resets Hayes mode register S0 to 1 (meaning that calls will be answered on the first ring).
3.10 Data Format Options
Data Format (Sync or Async)
V.25 bis, Dumb, Leased line modes
The data-format setting for the local modem and for the remote modem must be the same.
ASYNCHRONOUS. Data is transmitted and received in the character asynchronous format.
The character length (next option) must be the same for both communicating modems.
SYNCHRONOUS. If this setting is selected, data must be transmitted and received in the synchronous format. The appropriate transmitter clocking setting must be selected—see
TRANSMITTER CLOCKING later in this chapter. The synchronous data format is not available for data rates of 300, 19.2, or 38.4 Kbps.
Character Length
All modes (asynchronous operation only)
This option selects a character length of 9, 10, or 11 bits for character asynchronous operation.
The same character length must be selected for both the local and the remote modems. Use pushbuttons
1 and 3 to select the desired character length. The most widely used character-length setting is
10 bits.
9 BITS: 1 start bit, 7 data bits, and 1 or more stop bits.
10 BITS: 1 start bit, 8 data bits, including parity, and 1 or more stop bits.
11 BITS: 1 start bit, 9 data bits, including parity, and 1 or more stop bits.
Parity
All modes
Parity selections will be effective only if error correction or buffer mode has been enabled or if the modem is in 2-wire dial Hayes mode. For most applications, parity should be set to NONE.
The following parity options are available: NONE (no parity),
ODD, EVEN, MARK (parity is always 1) and SPACE (parity is always 0). All parity settings except
NONE automatically enable parity conversion (except in Hayes mode), meaning that the parity of received data will be converted to match the selected parity option.
56
CHAPTER 3: Options: Customizing the Modem Setup
In Hayes mode, autobaud overrides the front panel parity setting; this occurs when the modem receives the AT attention code.
3.11 Disconnect Options
When the modem is operating in
V.25 bis or Dumb mode, it is necessary to disconnect the modem from the telephone circuit once communications is completed. The most common form of disconnection is by dropping the
Data Terminal Ready (DTR) signal from the DTE. However, some applications may require one of the five available automatic disconnect methods listed below.
For all five disconnect options,
“disabled” means the modem will not disconnect in the presence of the conditions specified below
RX (Receive) Space Disconnect
Hayes, V.25 bis, Dumb modes
If this option is enabled, a 1.6second continuous space will cause the modem to disconnect.
NOTE
For Hayes mode operation, the RX Space Disconnect and TX Space Disconnect options must both be enabled or must both be disabled.
TX (Transmit) Space Disconnect
Hayes, V.25 bis, Dumb modes
When TX Space Disconnect is enabled, the modem will transmit
4 seconds of space prior to disconnecting from the line. This ensures a clean disconnect if RX space disconnect is enabled on the remote modem.
NOTE
For Hayes mode operation, the TX Space Disconnect and RX Space Disconnect options must both be enabled or must both be disabled.
Carrier Disconnect
V.25 bis, Dumb modes
If enabled, a 400-ms loss of carrier signal will cause the line to be disconnected.
(To set this option for Hayes mode, use S register S10.)
57
MODEM 32144
Line Current Disconnect
V.25 bis, Dumb modes
If enabled, a 400-ms loss of current will cause the line to be disconnected.
(To set this option for Hayes mode, use S register S10.)
RTS Disconnect
Hayes, V.25 bis, Dumb modes
When RTS Disconnect is enabled, if RTS is off for a selected period of time (20 to 140 seconds, user-selectable), the line will be disconnected. Use pushbuttons 1 and 3 to set the RTS-OFF period required for a disconnect.
3.12 Test Options
The test options affect certain tests
(as explained below) but do not activate tests.
DSR During Analog Loopback
All modes
When ON is selected, the Data
Set Ready signal is forced on when the modem is in the analog loopback test mode. In general, this option should be left ON (the default selection).
Remote Test
All modes
The Remote Test option allows you to prevent remote digital loopback or remote digital loopback self tests from being initiated on the local modem from a remote modem. If DISABLE is selected from the REMOTE TEST screen, the local will ignore testinitiation signals from a remote modem. If ENABLE is selected, tests can be initiated from a remote modem.
Note that there are two REMOTE
TEST screens. One is for the option just described; the other is used for selecting remote digital loopback tests. The Remote Test option screen (for preventing or allowing remote testing) looks like this:
REMOTE TEST
ENABLE DISABLE
3.13 EIA Options
The seven options described next allow control over specific EIA interface signals.
58
CHAPTER 3: Options: Customizing the Modem Setup
CTS to EIA
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
Regardless of the setting selected for this option, Clear to Send
(CTS) goes low. When DCD goes high during a V.42 error correction handshake or when DCE-DTE flow control is set to CTS on/off and a connection has been established with error correction or buffer mode enabled.
NORMAL. The Clear to Send signal is on while the modem is on-line.
RTS. The CTS signal immediately follows the RTS signal with no delay.
TRUE. The CTS signal follows
DTR.
CTS can also be set to be ON at all times regardless of DTR by using the Summary Setup feature.
(However, if CTS on/off has been selected from DCE-DTE screen 1,
V.42 flow control, while active, will override the CTS ON selection.)
To set CTS ON, refer to
Appendix B, Fig. B-4
, EIA
INTERFACE OPTIONS diagram.
Note that if you set CTS to ON using Summary Setup and then make a selection from the CTS to
EIA screen, the selection from the
CTS to EIA screen will cancel the
Summary Setup (CTS ON) selection.
NOTE
The modem also supports a
CTS option intended only for V.33 and Bell 208A/B operation, which is described later in this chapter under V.33 and Bell
208A/B Options.
CD to EIA
All modes
NORMAL. Carrier Detect (CD) is on while the modem is on-line.
TRUE. CD follows DTR supplied from the DTE.
TOGGLE. CD turns on whenever
DTR is present and then toggles off for 500 ms upon DTR disconnect, allowing the attached DTE to recognize that the call has ended and the connection has been dropped.
DSR to EIA
All modes
NORMAL. Data Set Ready (DSR) is on while the modem is on-line.
TRUE. DSR follows DTR supplied from the DTE.
CROSSOVER (XOVER). DSR is
ON without DTR and toggles for
500 ms upon local or remote disconnect.
59
MODEM 32144
DTR from EIA
All modes
This option allows the user to force the Data Terminal Ready
(DTR) signal on (TRUE), which may be needed if your computer or communication software does not supply a DTR signal.
NORMAL. DTR is supplied by the DTE. When DTR goes low, the modem sends a space disconnect
(if TX Space Disconnect is enabled) and goes on-hook.
TRUE. The DTR signal is internally forced ON regardless of the DTR status at the interface.
DTE Control of ALB (ALB- DTE
Ctrl’ed)
All modes
Analog loopback (ALB) testing can be initiated from the DTE via pin 18. Positive voltage activates the test, whereas negative voltage results in normal operation.
Disabling this option keeps the modem from responding to pin 18.
DTE Control of RDL (RDL- DTE
Ctrl’ed)
All modes
Remote digital loopback (RDL) testing can be initiated from the
DTE via pin 21. Positive voltage activates the test, whereas negative voltage results in normal operation.
Disabling this option keeps the modem from responding to pin 21.
Test Mode (TM to EIA)
All modes
This option controls pin 25, the test mode (TM) indicator, on the
RS-232 interface connector.
NORMAL. TM output is high
(active) only during test modes.
TRUE. TM output is high all of the time.
3.14 Modem Setups
The options listed below, through
RTS-CTS Delay, are available via the MODEM SETUPS screens.
Carrier Detect
All modes
This option selects the carrier detect level. To make a selection, first select either LEASED or DIAL from the CARRIER DET. LVL screen, depending on your application. The appropriate carrier detect level screen will then be displayed.
Leased-Line Applications
For leased-line use, the carrier detect level can be set for –43, –33 or –26 dBm. The default setting is
–26 dBm.
60
CHAPTER 3: Options: Customizing the Modem Setup
Dialup Applications
For dial line use, the carrier detect level can be set for –51, –41 or –34 dBm. The default setting is –51 dBm.
Transmit Level
All modes
This option controls the modem’s transmission level. To make a selection, first select either
LEASED or DIAL from the
TRANSMIT LEVEL screen.
Leased Line Applications
For leased lines, the transmission level can be set between 0 and –15 dBm, in 1-dBm steps. The standard setting is 0 dBm. (Use pushbuttons
1 and 3 to select the desired transmission level.)
Dialup Applications
The transmission level for dial lines can be set as either programmable, if you are using RJ-45S connectors, or permissive, fixed at –10 dBm
+/–1 dBm, which is the most common setting.
Signal Quality
All modes
This option sets the threshold for the ER (error) indication during normal operation. You can choose either 10^3, one error in 1000 bits, or 10^5, one error in 100,000 bits.
The settings of the Signal Quality and Carrier Detect Level options determine the threshold values the modem uses as criteria for entering
Leased Line Auto-Recovery mode.
Compromise Equalizers
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
NOTE
The compromise equalizers only affect V.32 operation
(4800 bps to 14.4 Kbps, asynchronous/synchronous, full duplex).
For most applications, the automatic adaptive equalizer setting will provide all the equalization necessary to compensate for line impairments, meaning that equalizer adjustments generally will not be necessary. However, in the event that equalizer adjustment is needed, any of four types of compromise equalization can be selected: Type I (T-I on the LCD),
Type II (T-II), Type III (T-III) and
Type IV (T-IV). The equalizer can also be turned OFF.
61
MODEM 32144
Where line conditions are atypical, it may be necessary to adjust the equalizers to optimize the signal quality. If adjustment is necessary, refer to the quality screen for guidance; this screen shows a relative indication of the signal quality, in both numeric and graphic form.
Trellis Code
Hayes, V.25 bis, Dumb, Leased line modes (except V.33)
Trellis coding provides performance advantages for all modulation patterns. The modem’s
CCITT compliant trellis coder is normally enabled at speeds of
7200 bps and above, but may be negotiated off by a modem that is not equipped with a trellis coder at
9600 bps. The trellis code option allows the user to enable or disable the trellis coder.
Transmitter Clocking
All modes
This option selects one of three possible sources for the transmitter timing signal:
INTERNAL. The timing of the modem and data terminal transmitting circuits is provided by an internal clock within the modem.
RECEIVED (RX-CLK). The timing of the data received from the remote modem is used to control the timing of the transmitted data. This timing mode is used if the modem’s transmit timing must be controlled by a remote source.
EXTERNAL. The timing of the modem and data-terminal transmitting circuits is synchronized to an external clock from within the data terminal and is provided to the modem via the
DTE connector pin 24. This mode of clocking is used if the
DTE must be in control of the modem’s transmit timing. The modem’s minimum and maximum speed must be set to approximately the same speed as the DTE clock.
(To set the maximum speed, use the Speed Limit option.)
T1 Timer
Hayes, V.25 bis, Dumb modes
The T1 Timer option is only effective if the Summary Setup
Multimode Handshake option is set to 0 (T1 timer).
The T1 Timer option determines how long the ALX modem will attempt to handshake with a calling
V.32 modem before falling back to a lower speed. The available T1
Timer settings are 0, 0.3, 0.8, 1.6
and 3.0 seconds.
62
Normally, as part of the V.32
handshake, the calling modem begins sending a sequence to the answer modem while the answer modem is still sending answer tone—in this case, there is no T1 timer. However, the V.32
Recommendation allows for a T1 time of up to 3 seconds, meaning that the answer modem may be set to wait (before falling back) for up to 3 seconds.
Auto-Retrain
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
If the modem makes a connection at one of the V.32 rates
(4800 bps to 14.4 Kbps) or V.22 bis rate (2400 bps), it can request that the remote modem send a retrain sequence.
ENABLE. The modem will request a retrain sequence.
DISABLE. The modem will not request a retrain sequence.
Answer/Originate Default
Leased line modes (and manual originate/answer dial operation)
This option sets the modem to default to either answer or originate status when it makes a connection at one of the V.32 rates
(4800 to 14.4 Kbps). It also applies to the V.22 bis rate (2400 bps), for dial operation only.
CHAPTER 3: Options: Customizing the Modem Setup
ANSWER. The modem is set to answer mode.
ORIGINATE. The modem is set to originate mode.
Answer Tone
Hayes, V.25 bis, Dumb modes
The answer tone frequency is selectable only if the maximum data rate has been set to 1200 bps
(via the SPEED LIMIT menu), in which case the answer tone can be set to either 2225 or 2100 Hz.
Otherwise, the answer tone frequency will be 2100 Hz (the standard for V.32 operation). In general, this setting should not be changed (even for fallback with
Bell standard modems, which use a
2225 Hz answer tone).
Front-Panel Control
All modes
For security purposes, this option may be used to make it difficult for unauthorized users to modify the modem’s configuration. If Front-
Panel Control is disabled, the modem will not respond to Quick
Setup selections or to changes made through option screens accessed via the SETUP menus.
In addition, Hayes configuration commands (and the &W and &Z
Hayes commands) will have no effect, and stored user profiles (for
Hayes mode) cannot be altered.
Note that even if Front-Panel
63
MODEM 32144
Control is disabled, front-panel screens that do not affect the modem configuration (such as
AUTO-DIAL and test modes) will function.
Speaker
Two speaker options are available:
Speaker Control and Speaker
Volume.
Speaker Control
All modes
ON. Speaker is on during the full modem handshake process and while the unit remains on-line.
OFF. The speaker is off; the call cannot be audibly monitored.
ON TILL CD. Speaker remains on until a carrier signal (CD) is detected.
Speaker Volume
All modes
The speaker volume can be set to LOW, MEDIUM, or HIGH.
Guard Tones
Hayes, V.25 bis, Dumb modes
Guard tones are used—in V.22 and V.22 bis modes only—to assure proper band separation on systems that use international telephone circuits. Unless you will be using international circuits in one of these modes, you should turn the guard-tone option OFF. If guard tones are required, their frequency can be set to 550 Hz or 1800 Hz
(the most commonly used guardtone frequency).
V.13 Operation
V.25 bis, Dumb, Leased-line modes
(synchronous operation only)
OFF. V.13 operation is off. This setting allows normal full-duplex operation. (All other selections are for enabling V.13 operation.)
TX ONLY. Status of RTS will be sent to remote modem.
RX ONLY. Carrier Detect (CD) will be controlled by V.13 signals from the remote modem.
TX AND RX. Status of RTS will be sent to remote modem, and CD will be controlled by V.13 signals from the remote modem.
To select one of the four V.13
options, press pushbutton 1 or 3— with the V13 screen displayed— until the selection you want is displayed. For half-duplex point-topoint applications, select TX AND
RX. For multidrop-type applications, select RX ONLY for all modems at the host site and TX
ONLY for all modems at the remote site.
64
CHAPTER 3: Options: Customizing the Modem Setup
NOTE
If V.13 operation is enabled
(TX ONLY, RX ONLY or TX
AND RX), the data format is automatically changed to synchronous. However, if you enable V.13 operation and later disable it, the data format does not automatically revert to asynchronous. To restore the asynchronous data format, you must use the
Data Format option.
3.15 V.33 and Bell 208A/B Options
The following three options are available on the modem and are intended only for V.33 or Bell
208A/B operation. (For Bell 208 operation, see also Satellite Delay,
Turnaround Delay, 208 Phase
Detection, Answer Tone Detection and V.32/208 Auto-Detect Mode later in this chapter.)
Carrier Type
V.33, 208, V.32/208 modes
SWITCHED (SWITCH). For
2-wire applications, the carrier type option must be set for switched carrier operation.
CONSTANT. Constant, or continuous carrier can be used only for 4-wire leased line applications (although such applications may also use switched carrier).
CTS
V.33 mode
This option applies only to V.33
leased-line applications that use constant carrier.
RTS. The CTS signal follows RTS.
ON. CTS is always ON.
NOTE
The modem also supports a
CTS to EIA option, which is
described in Section 3.11.
RTS-CTS Delay (CTS Delay)
V.33, 208, V.32/208 modes
The available RTS-to-CTS delay settings are 0, 15, 50, or 150 ms.
However, the only available choices for 208A/B operation are 50 and
150 ms. If you select 0 or 15 ms, the actual delay in 208A/B mode will be 50 ms.
65
MODEM 32144
NOTE
RTS-to-CTS delay is not effective if the CTS option is set to ON (always ON). For
V.33 operation, RTS-to-CTS delay is only effective for 4wire leased line applications that use constant carrier.
RTS-CTS Delay with V.13 Operation
If the V.13 Operation option is set to TX ONLY or TX AND RX, the actual RTS/CTS delay time may differ from the selected RTS/CTS
Delay setting. The actual RTS/CTS delay depends on the data rate, as shown in Table 3-2.
Data Rate bps
14,400
12,000
9600
7200
4800
2400
1200
600
Table 3-2. RTS/CTS Delay with V.13 Operation.
0
10
16
29
65
8
6
9
9
Delay Setting, ms
15 50
Actual Delay, ms
15
16
29
65
15
15
15
15
50
50
50
65
50
50
50
50
150
106
106
106
106
106
150
150
150
66
CHAPTER 3: Options: Customizing the Modem Setup
LCD Intensity
All modes
This option allows you to use pushbutton 3 (for INC or increase) to darken characters on the LCD or pushbutton 1 (for DEC or decrease) to lighten them.
3.16 Options Accessible Only via
Summary Setup
The options described in this section can only be changed through the modem’s Summary
Setup feature, which is explained in Appendix B. For most applications, it is not necessary to change these options—they are intended primarily for specialized applications. For an explanation of how to change these options, available option settings and the default setting for each option, see
Appendix B
.
Three additional options accessible only via Summary Setup include Operating Mode Fallback,
Rate Renegotiation Procedure, and
Speed Fallback.
3.16.1 D
IAL
L
INE
O
PTIONS
(The numbers used to select different settings for each option on the Summary Setup LCD screen are arranged according to option groups—dial line options, V.42
error-correction options, etc. For details, see Appendix B.)
Wait for Carrier
V.25 bis, Dumb modes
The time the modem will wait for a carrier signal when originating a call can be set for 30, 45, 60, or 75 seconds. (Note: In Hayes mode, the wait-for-carrier time is determined by the value in register S7.)
3.16.2 V.42 E
RROR
-C
ORRECTION
O
PTIONS
Selective Retransmission
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
This option allows the modem to communicate with certain modems that are not able to respond to the
MNP selective retransmission command.
ENABLE. This setting allows the modem to request retransmission of a single information frame (in the event of a transmission error).
DISABLE. Data can be retransmitted only in a series of information frames.
67
MODEM 32144
DCE Pass-through Flow Control
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
This option affects DCE-DTE flow control only. It is effective only if error correction or buffermode/speed conversion is enabled.
ENABLE. The modem will pass flow-control characters received from the remote modem to the local DTE.
DISABLE. The modem will not pass flow control characters from the remote modem to the local
DTE.
Link Flow Control
Hayes, V.25 bis, Dumb, Leased line modes (except V.33)
This option is effective only if buffer-mode/speed conversion is enabled and a buffer link without error correction is established. Do not enable Link Flow Control if binary data will be transmitted or received.
ENABLE. The modem will check for X-ON/X-OFF (DC1/DC3) flowcontrol characters received from the remote modem to determine whether to stop or start/restart data transmission to the remote modem. A DC3 control character will cause the modem to stop data transmission and hold data in its buffer until it receives a DC1 control character (which instructs the modem to resume transmission).
If Link Flow Control is enabled with DTE-DCE flow control set to
RTS on/off and DCE-DTE flow control set to CTS on/off on both the originating and answering modems, and both modems establish a buffer-mode connection, the modems will exchange flow control signals across the link in the form of DC1 and DC3 characters. If the data being exchanged contains a DC3 character (e.g., binary or executable files), this will signal the remote modem to halt and buffer all data from the remote DTE until the local DTE sends a DC1 character.
DISABLE. The modem will ignore XON/XOFF (DC1/DC3) flow -control characters received from the remote modem.
SLAVED. Link flow control is controlled by the DCE-DTE Flow
Control option. If DCE-DTE Flow
Control is set to NONE or CTS,
Link Flow Control is disabled.
Otherwise it is enabled.
68
CHAPTER 3: Options: Customizing the Modem Setup
3.16.3 D
ATA
P
UMP
O
PTIONS
Phase Reversal in Answer Tone
All modes
When enabled, the Phase Reversal in Answer Tone option signals the telephone network to turn off its echo cancelers. For virtually all applications, phase reversal should be enabled (the default setting).
Satellite Delay
208, V.32/208 modes
This option facilitates transmission over satellite links
(but does not permit fast-turnaround operation). When the
Satellite Delay option is on, RTS is inhibited for 275 ms after the answer tone stops and after the
DSR signal comes on. This delay occurs at both the originating and answering modems, allowing the echo suppressors on the telephone link to be enabled.
Turnaround Delay
208, V.32/208 modes
This option is intended for circuits where echo is a problem. It prevents the modem from receiving an echo of its own transmitted data.
When the Turnaround Delay option is on, CD (pin 8) is held low for 150 ms after RTS is turned off.
If the modem detects an energy loss during the delay, it turns CD on 52 ms after detecting the loss. If the modem does not detect an energy loss, it turns CD on 52 ms after the end of the delay. The modem ignores any energy loss during the first 8.5 ms.
V.32 Mode
Hayes, V.25 bis, Dumb, Leased-line modes (except V.33)
This option is used to select
CCITT V.32 bis operation or V.32
extended operation.
V.32bis. When V.32bis mode is selected (factory-default setting), the following are available: Rate
Renegotiation Procedure (RRP), a data rate of 7200 bps, and a
RATE screen that allows the user to manually initiate RRP.
RRP enables the modem to automatically fall back or fall forward to a lower or higher data rate during data transmission in response to changes in signal quality. Selecting V.32 bis mode makes RRP available as an option; however, RRP will not function unless it is enabled. (Enabled is the factory-default setting.) RRP is described fully in Section 4.3.2.
When V.32 bis mode is selected, a RATE screen is available from
MAIN MENU screen 3. The RATE screen can be used to manually initiate RRP for diagnostic purposes. For additional information, see RATE CHANGE
SCREEN in Section 8.7.
69
MODEM 32144
When V.32bis mode is selected,
7200 bps can be selected as the maximum or minimum data rate
(using the Speed Limit option).
When V.32bis is not selected,
7200-bps operation is not available.
NOTE
By definition, V.32 bis operation includes the ability to operate at 12,000 and 14,400 bps. However,
RRP, the 7200-bps data rate, and the RATE screen are available on the modem when V.32 bis is selected.
V.32 EXTENDED. V.32 extended mode disables the V.32 bis features.
In V.32 extended mode, the modem’s functionality is identical to that of modems prior to incorporation of the CCITT V.32
bis recommendation.
208 Phase Detection
208, v.32/208 modes
NORMAL. Conditions the modem’s 208 receiver for compensated modulation detection for improved performance with older 208 modems.
V.22 bis S1 Duration
Hayes, V.25 bis, Dumb modes
This option affects the duration of the S1 signal during a V.22 bis handshake. To allow the modem to connect properly with certain manufacturers’ V.22 bis modems that do not conform fully with the
V.22 bis standard, the modem’s S1 signal duration may have to be changed from the default setting,
100 ms, to 150 ms. The CCITT V.22
bis specification specifies an S1 duration of 100 ms.
V.32/208 Auto-Detect Mode
208, V.32/208 modes
To enable V.32/208 auto-detect mode, the V.32/208 auto-detect
Summary Setup option must be set to 1 for enable and the front panel
Speed Type option must be set to
AUTO. (If you select the V.32/208 auto-detect Quick Setup, the modem automatically sets both of these options to enable V.32/208 auto-detect mode.)
When V.32/208 auto-detect mode is enabled, the modem automatically selects V.32 or Bell
208 mode, depending on the mode of the originating modem.
3.16.4 M
ISCELLANEOUS
O
PTIONS
V.25bis DTR Dialing
V.25 bis mode
This option enables or disables
DTR dialing for V.25 bis mode only.
If this option is enabled, DTR dialing will function in V.25 bis mode—depending on which of these modes (i.e., which autodialer) is enabled.
70
CHAPTER 3: Options: Customizing the Modem Setup
ENABLE. Enables DTR dialing for
V.25 bis mode.
DISABLE. Disables DTR dialing for
V.25 bis mode.
Analog Loopback Make Busy
All modes
If the Analog Loopback Make Busy option is enabled, the modem will provide a busy indication to the dial-line interface when the modem is in analog loopback test mode.
Answer Tone Detection
208, V.32/208 modes
ENABLE. Conditions the originating modem’s receiver to wait for answer tone detection before going on-line.
DISABLE. Conditions the originating modem to go on-line without requiring answer tone detection. This setting accommodates operation with automatic calling units that connect the modem to the line at the end of answer tone.
Multimode Handshake
Hayes, V.25 bis, Dumb modes
This option determines how long the modem will attempt to handshake with a V.32 modem before falling back to a lower speed.
T1 TIMER. If the T1 timer setting is selected, the modem will attempt to handshake with a calling
V.32 modem for the time specified by the T1 Timer option.
V.32 bis ANNEX A. If the V.32 bis
Annex A setting is selected, the modem will handshake according to the conventions established in
Annex A of the CCITT V.32 bis recommendation. Handshaking using the Annex A selection will generally be faster than handshaking based on the T1 timer.
Remote RTS Signaling
Leased line modes (except V.33)
This option provides remote RTS signaling in asynchronous mode.
When the Remote RTS Signaling option is on, the state of the Ready to Send (RTS) signal is transferred across the modem link (for diagnostic purposes) without affecting normal operation. The
Remote RTS Signaling option allows control over the remote
Carrier Detect (CD) signal as described below.
Note the following restrictions for Remote RTS Signaling: The two modems must be connected at a data rate of 7200 bps or higher.
The V.13 Operation option must be off. The DTE-DCE and DCE-
DTE Flow Control options should not be set to RTS on/off.
71
MODEM 32144
ON. The state of RTS input
(EIA pin 4) will be signaled to the remote modem’s CD output, and
CD (pin 8) on the local modem will follow the state of the remote modem’s RTS input. (The typical propagation delay is less than 800 ms.)
OFF. This setting allows for normal operation: The state of
RTS at the local modem will not be signaled to the remote modem.
Leased Line Interrupt
Leased-line modes (except V.33)
The Leased Line Interrupt option controls a modem designated as the answer modem and configured for Leased Line
Auto-Recovery (Section 4.9) as stated below.
ON. The answer modem will answer incoming calls, regardless of the state of the leased line (CD
ON or OFF).
OFF. This setting allows for normal operation: If Carrier
Detect (CD) is ON, this means the leased line is trained and working, and the answer modem will ignore any incoming calls on the dial line.
Wait for MNP Link Request
Hayes, V.25 bis (Async only),
Dumb, Leased-line modes
(except V.33)
When a remote originating modem attempts to establish an
MNP connection with a modem, the answer modem will wait up to
3 seconds, by default, to receive the MNP link request. This option allows the user to configure the modem to wait longer (7 seconds) for an MNP link request. The longer wait time allows the modem to establish MNP connections under conditions that require multiple link requests.
CFI AB Response on Disconnect
V.25 bis
In V.25bis mode, the originate modem sends a CFI AB result code when a call is aborted because the user has selected HANGUP from the front panel or because of DTR loss. If the CFI AB Response on
Disconnect option is enabled, the originate modem will also send a
CFI AB result code upon call disconnect.
72
CHAPTER 3: Options: Customizing the Modem Setup
Low-Profile DIAG LED Function
All modes
This option may be used to change the function of the DIAG
LED on low-profile modems
(Appendix D), as explained below.
CONNECT STATUS. DIAG LED on indicates the modem’s diagnostic port is actively connected. DIAG LED off indicates the diagnostic port is not connected.
DTR STATUS. DIAG LED on indicates DTR is high. DIAG LED off indicates DTR is low.
73
MODEM 32144
4. General Operation and Special
Features
This chapter describes the following features and operational modes (listed here in the order in which they are presented):
• Quick reset
• Phone number storage
• Automatic fallback
• Dumb mode and Bell 208 operation
• V.13 operation
• DTR dialing
• Dial Line Auto-Recovery
• Leased Line Auto-Recovery
• Security operation
• Modem-controlled remote control
• Diagnostic interface control
The status screens, which display data concerning the operational status of the modem, are discussed in Section 7.6 . Instructions for using the pushbutton controls and
LCD are included in Section 3.2.
4.1 Quick Reset
For a reset of the modem, whereby option settings are not changed but the modem is cleared for a new start and the ROM memory chip is checked, select RESET from MAIN
MENU screen 3. The modem will display the power-on screen for a few seconds and then the EIA status screen. This feature enables you to reset the modem without powering down the unit.
4.2 Storing Phone Numbers
4.2.1 U
SES
The front panel PHONE screen allows you to store a single phone number to be used later for—
• Autodialing from the front panel or using the Hayes or
V.25 bis mode autodialer
• DTR dialing
• Leased-line or dial-line autorecovery.
74
CHAPTER 4: General Operation and Special Features
The number stored via the
PHONE screen is stored in phone cell 0 (zero). To autodial the frontpanel phone number in Hayes or
V.25bis mode, specify phone cell 0.
4.2.2 H
N
UMBER
OW TO
S
TORE A
P
HONE
To store a phone number using the modem’s front panel controls, select PHONE from MODEM
SETUPS screen 5. The following screen will be displayed:
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
DEC CTRL INC
If a number has been previously stored, the number will be displayed on the top line of the
LCD (instead of dashes, as shown above). Only one phone number—
24 characters maximum—can be stored via the front panel.
Enter the number to be stored by using the front-panel pushbuttons as follows:
• Use the right and left arrow pushbuttons to go to the position on the LCD where you want to enter or change a number or character. The number or character at the current cursor location flashes on and off.
• Use pushbutton 1 to decrease a number at the current cursor location or pushbutton 3 to increase a number.
• Use pushbutton 2 (CTRL) to cycle through the dialing control characters. The dialing control characters are listed in
Table 4-1
, in the order in which they appear on the LCD if you cycle through them. Dialing control characters can be saved with a phone number to perform the functions listed in
Table 4-1
when the number is dialed.
The phone number is saved when you return to the MAIN
MENU.
75
MODEM 32144
Character
Table 4-1. Dialing Control Characters
(for use with front-panel PHONE screen)
Function
(space)
(comma)
W(or colon)
P
T
*
#
/ (diagonal)
A-D
R
. (period)
L
: (colon, or W)
- (dash)
Used only for clarity.
Effects 2-second pause.
Wait 30 seconds for dial tone before proceeding.
Sets pulse dialing mode.
Sets tone dialing mode.
Dial * (tone dialing only).
Dial # (tone dialing only).
Prefix required for use with R (/R).
Used in some PBX applications (tone dialing only).
Configures modem for Dial Line Auto-
Recovery. Requires / prefix. See Dial Line
Auto-Recovery section later in this chapter.
Marks end of phone number.
Links a phone number to another number to be dialed as an alternate. See L—LINK in
Section 5.4.
Wait 30 seconds for dial tone before proceeding.
Used only for clarity (no function).
NOTES: A, B, C, and D are used in some private branch exchange (PBX) applications. The * and # symbols are sometimes used for access to remote computer systems.
76
CHAPTER 4: General Operation and Special Features
4.3 Automatic Fallback
The modem incorporates three automatic fallback features that can be controlled by the user:
• Operating-Mode Fallback—
Provides compatibility with modes that use any of several different operating modes.
• Two options for automatic data rate adjustment: Rate
Renegotiation Procedure
(RRP) and Speed Fallback—
These features allow the modem to automatically select the highest possible data rate, depending on the signal quality.
4.3.1 O
PERATING
-M
ODE
F
ALLBACK
This section applies to dial-line operation only.
When the modem originates or answers a call, it determines from the “handshake” routine with the other modem the most efficient operating mode that is supported by the other modem and automatically “falls back” to that mode. The modem supports two alternatives for operating-mode fallback: V.22 bis/Bell 212A/Bell
103 fallback operation (default setting) and V.22
bis/V.22/V.21/V.23 fallback operation. Operating-mode fallback functions when the modem is in either manual or automatic originate mode or manual or automatic answer mode.
For communication within the
United States, use the default setting for Operating-Mode
Fallback—V.22bis/Bell 212A/Bell
103.
V.22 bis/V.22/V.21/V.23 Fallback
Operation
To configure the modem for V.22
bis/V.22/V.21/V.23 fallback operation, refer to Appendix B,
Fig. B-7
. Change the Operating
Mode Fallback parameter shown in the diagram from 0 (the factory setting) to 1. (This is the only way the Operating Mode Fallback setting can be changed.)
Changing the Operating Mode
Fallback parameter to 1 has the following effects:
• The modem will be configured for V.22 bis 2400-bps/V.22
1200- and 600-bps/V.21 300bps/V.23 1200/75 bps fallback operation. As a result, 600 and
1200/75 bps will appear as additional selections on the
SPEED LIMIT LCD screens.
• Fallback to V.22 bis Bell 212A and Bell 103 compatibility is disabled.
• An AT command is available (in
Hayes mode only) that allows control over operating mode as follows: F0—Multi-mode operation (default); F1—V.21,
300 bps; F2—V.22, 600 bps;
F3—V.23, 1200/75 bps; F4—
77
MODEM 32144
V.22, 1200 bps; F5—V.22bis,
2400 bps; F6—V.32 (highest common speed). Except for multi-mode operation, the mode and speed are limited to the mode and speed specified.
Multi-mode operation allows the modem to automatically fall back to the most efficient mode that can be used by both modems.
Available Fallback Modes
The preferred mode is V.32/
V.32bis (4800 bps or higher, asynchronous/synchronous, full duplex); however, if the other modem does not support V.32 or
V.32 bis, the modem will fall back to one of the modes listed below.
The fallback modes are listed in the order in which they are attempted by the modem in normal operation:
Table 4-2. V.22 bis/Bell 212A/Bell 103 Fallback (Default)
Mode
V.22 bis
Bell 212A
Bell 103
Description
2400 bps asynchronous/synchronous
1200 bps asynchronous/synchronous
0-300 bps asynchronous
All modes are full duplex.
If V.22 bis/V.22/V.21/V.23
fallback operation is enabled, the following fallback modes are available. As in the previous list, the modes are listed in the order in which they are attempted by the modem.
78
CHAPTER 4: General Operation and Special Features
Mode
Table 4-3. V.22 bis/V.22/V.21/V.23 Fallback
Description
V.22 bis
V.22
V.21
V.23
2400 bps asynchronous/synchronous
1200 and 600 bps asynchronous/synchronous
300 bps asynchronous
1200/75 bps asynchronous
All modes are full duplex.
The operating mode can be controlled by the user through the
SPEED LIMIT screens on the LCD in all modes except Hayes mode.
See Chapter 3 for details.
NOTE
If you want to select 1200/75 bps for both the maximum and minimum rate, V.22
bis/V.22/V.21/V.23 fallback must also be selected.
4.3.2 A
UTOMATIC
R
ATE
A
DJUSTMENT
Both sections below apply to both dial line and leased line operation.
Rate Renegotiation Procedure (RRP)
If Rate Renegotiation Procedure
(RRP) is enabled, the modem will automatically fall back or fall forward to a lower or higher data rate at any time during data transmission (without retraining) in response to changes in signal quality. Data rate adjustments are limited to the range of 4800 to
14,400 bps and are also limited by the minimum and maximum rate settings of the Speed Limit option.
If satisfactory performance cannot be attained at any of the available data rates, the modem will initiate a
GSTN cleardown (line disconnect).
If the originate modem attempts to negotiate a rate that is lower than the minimum rate setting of the answer modem, the answer modem will initiate a GSTN cleardown.
RRP will function only if Speed
Fallback is enabled (factory default) and if the V.32 Mode option is set to V.32 bis (factory default). (Both are Summary Setup options.)
The factory default setting for
RRP is enabled. To change the RRP option, refer to Appendix B, Fig. B-
7
. Change the Rate Regeneration
Procedure (RRP) parameter shown in the diagram to 0 (disable) or 1
(enable). (This is the only way the
RRP option can be changed.)
79
MODEM 32144
4.4 Dumb Mode and Bell 208
Operation
Table 4-3
lists dialing parameters that may be used to modify Dumb mode or Bell 208 dialing operations.
4.4.1 M
ANUAL
O
RIGINATE
/A
NSWER
O
PERATION
When the modem is operating in
Dumb mode or configured for Bell
208 operation, data calls may be manually originated from a phone set. (Plug the phone into the modem jack marked “PHONE.”)
For manual-originate operation, the remote modem may be configured for either automatic or manual answer. For manualoriginate/answer operation, one modem must be set to ANSWER and one must be set to
ORIGINATE via the ANS/ORG
DEFAULT screen. For either type of operation, use the Quick Setup to configure the modem. (The
Dumb mode Quick Setup defaults to asynchronous operation; the Bell
208 and V.32/208 Quick Setups default to synchronous operation.)
Any of these three Quick Setups will set the modem to originate mode. If you want to set your modem to answer mode, use the front panel controls to access the
ANS/ORG DEFAULT screen
(MODEM SETUPS screen 4). Then select ANSWER (answer mode).
Originating a Data Call Manually
To manually originate a data call, select TALK from MAIN MENU screen 1. The MANUAL-DIAL screen will now be displayed. Select
TALK again. This puts the modem in talk mode. Lift the handset and listen for the dial tone. Dial the phone number of the remote modem.
When you hear a high-pitched answer tone, select DATA from the
MANUAL-DIAL screen, and place the handset back on the cradle.
The LCD will display the status of the communication. Typically it will appear as follows:
D TR
9600
MR RS
The data link between the two modems is now established, and data transfer can begin.
CS
CD
80
CHAPTER 4: General Operation and Special Features
Answering a Data Call Manually
An incoming call may be answered manually or automatically, although to answer a data call manually, the Auto-Answer option must be disabled. Before the call is received, the modem must be set to
TALK, as explained in the previous section. The unit that will be switched to DATA mode first must be set for answer mode (using the answer/originate option). The other unit must be set for originate mode.
NOTE
If you set the modem to talk mode, the phone will ring, but the modem will not answer, even if the Auto-
Answer option is enabled.
After the phone has rung, and you have answered it, the modem must be set for data mode: With the MANUAL-DIAL screen still displayed, select DATA. This puts the modem in data mode.
The first person to go to data mode will hear his telephone disconnect as his modem connects.
The other person must wait until he hears an answer tone, and then switch to data mode (select DATA).
When both modems are in data mode, the data communication will begin. The LCD will display the status of the connection.
Terminating a Data Call
There are several ways a data call can be terminated. One way is through communication software—by following the software manufacturer’s instructions. An alternate method is to switch to the
TALK option (talk mode) on the
MANUAL-DIAL screen, as described in the previous section.
Another method is to drop the
DTR signal from the DTE (by software control or by turning the
DTE off).
4.5 V.32/208 Auto-Detect Mode
When V.32/208 auto-detect mode is enabled, the modem will automatically select either V.32
(V.32/V.32 bis) or Bell 208 operation. These two types of operation are described below.
4.5.1 V.32/V.32
BIS
O
PERATION
In V.32/208 auto-detect mode, an answering modem will, upon detection of a V.32 handshake, operate with the following options set as shown:
• Data format—synchronous
• V.13 operation—TX and RX
• Carrier type—constant
• CTS to EIA—RTS (CTS follows
RTS)
81
MODEM 32144
4.5.2 B
ELL
208 O
PERATION
In V.32/208 auto-detect mode, an answering modem will, upon detection of an originating Bell
208B modem, operate with the following options set as shown:
• Data format—synchronous
• V.13 operation—off
• Carrier type—switched
The originating Bell 208 modem must be configured to detect the
Bell 208 answer tone before it goes to data mode. (Some 208 modems may not have this option.)
4.5.3 A
UTOMATIC
F
ALLBACK
When the modem is configured for
V.32/208 auto-select mode and in answer mode, it will not handshake in V.22 bis, Bell 212/103 or
V.21/V.22, V.23 mode.
local RTS control of a remote CD signal without actual ON-OFF switching of the modem carrier.
The following explains how the modem will respond to RTS signals when it is configured for V.13
operation:
When RTS is raised high by the terminal, the V.13 ON PATTERN will be sent. The modem will then raise CTS (and data can be sent).
When RTS is brought low, the V.13
IDLE PATTERN will be sent, and the modem will drop CTS. (If V.13
TX is enabled but the modem data pump is not ready to send, for example, if it is training or retraining, raising RTS will cause
CTS to be raised, but the V.13 ON
PATTERN will not be sent.) When
V.13 RX is enabled, CD will turn
ON if the V.13 ON PATTERN is detected; CD will turn OFF if the
V.13 IDLE PATTERN is detected or if the modem retrains, loses carrier, or is reset.
4.6 V.13 Operation
The modem can be configured for
CCITT V.13 operation (which emulates half duplex operation) for either point-to-point or multidrop applications. (The correct options for these applications are identified in
Chapter 3
.) The modem normally operates in full duplex; however, some applications (such as certain network environments) may require control of a remote CD signal by a local Request to Send
(RTS) signal. V.13 operation allows
4.7 DTR Dialing
NOTE
To use DTR dialing in V.25
bis or Penril mode, you must use the Summary Setup feature, as explained in
Chapters 6 (V.25 bis) and 7
(Penril).
82
4.7.1 D
IALING A
S
TORED
N
UMBER
DTR dialing allows you to set up the modem to automatically dial a stored number even when the autodialer has not been enabled.
To enable DTR dialing, select
DTR from the DIALER option screen.
When DTR dialing is enabled, an
OFF-to-ON transition of DTR will cause the modem to automatically dial the number previously stored using the front panel LCD. DTR must remain on for at least 50 ms to effect automatic dialing. A 50-ms drop of DTR will abort the process or disconnect the call. When DTR goes high again for at least 50 ms, the automatic dialing process will begin again.
4.7.2 A
NSWER
M
ODE
O
PERATION
If the modem is set for DTR dialing, it will automatically answer without DTR. However, it will not be able to transfer data until DTR goes high. The call may be terminated by dropping DTR.
4.8 Dial Line Auto-Recovery
CHAPTER 4: General Operation and Special Features
4.8.1 S
ETTING UP THE
M
ODEM FOR
D
IAL
L
INE
A
UTO
-R
ECOVERY
Two steps are required to set up the modem for Dial Line Auto-
Recovery: You must first enter or store the number to be dialed together with the /R command; then you must enable Dial Line
Auto-Recovery.
Entering the /R Command
To configure the modem for Dial
Line Auto-Recovery from the front panel, enter the phone number to be dialed followed by /R (the Dial
Line Auto-Recovery command) on the PHONE screen:
The Dial Line Auto-Recovery feature allows you to setup the modem for a dial-up application so it will automatically redial to restore a broken connection if the modem goes on-hook. In this way, the Dial Line Auto-Recovery feature emulates the reliability of a leased line connection.
T555-4545/R
DEC CTRL INC
If you need assistance, see
Section 4.2, Storing Phone
Numbers
.
An alternate way to configure the modem for Dial Line Auto-
Recovery (in Hayes mode only) is to use the Hayes AT &Z command to store the phone number to be redialed and the /R command in memory location 0, by entering
AT &Z0=T555=4545/R
83
MODEM 32144
Enabling Dial Line Auto-Recovery
Dial Line Auto-Recovery will not be active until you select DIAL from the front panel AUTO-DIAL screen
(or, in Hayes mode, use the command AT DS=0—or, in V.25 bis mode, use the command CRS 0). If power is removed from the modem, you will have to re-enable
Dial Line Auto-Recovery. To disable
Dial Line Auto-Recovery, select
RESET from MAIN MENU screen
3.
4.8.2 R
ECOVERY
P
ROCEDURE
If Dial Line Auto-Recovery is enabled and the modem goes onhook, it will redial the stored phone number up to 10 times. It will redial 5 times at 30-second intervals, wait 2 hours, and then redial 5 additional times at 30second intervals. The modem stops redialing after 10 attempts.
If a connection has been broken and re-established and is then broken again, the full sequence of
10 redial attempts will not occur unless the modem has been on-line for more than 1 hour. The modem will redial, but it is programmed not to exceed more than 10 redial attempts in 1 hour.
4.9 Leased Line Auto-Recovery
The Leased Line Auto-Recovery feature allows the modem to automatically restore operation for a leased line application by using dial lines as a backup when conditions on the leased lines deteriorate. The modem uses signal quality and loss of carrier detect to determine if line conditions are unsatisfactory.
Leased Line Auto-Recovery is accessed via the AUTO-RECOVERY screen on the front-panel LCD.
The following conditions are required for Leased Line Auto-
Recovery operation:
• Leased Line Auto-Recovery must be enabled (using the
Leased Line Auto-Recovery
Select option) on both communicating modems.
• The Leased Line Auto-Recovery
Select, Return, and Test options must be set correctly on both communicating modems, as explained in the following sections.
• A dial backup line (or lines) must be installed.
• The phone number to be dialed
(the backup line) must be stored in the originate modem, as explained in the previous section.
• Auto-answer must be enabled on the answer modem.
84
CHAPTER 4: General Operation and Special Features
4.9.1 A
UTODIAL
B
ACKUP
The modem will automatically dial the stored number to connect over the backup line if it detects poor signal quality (ER) or a loss of carrier detect (CD) on the leased line. The criteria used by the modem in assessing the condition of the leased line depend upon the settings of the Signal Quality option (one error in 10 3 or 10 5 bits) and the Carrier Detect Level option (-43, 33, or -26 dBm).
Dial Backup Message
When dial backup occurs (either automatically or by operator intervention), the following message will flash on the front panel LCD of both modems:
ATTENTION:
DIAL BACKUP
This message will clear when the modem returns to the leased line.
If you want to clear the message while the modem is still in dialbackup mode, press the ENT pushbutton.
4.9.2 E
XIT FROM
L
EASED
L
INE
A
UTO
-
R
ECOVERY
If the Leased Line Auto-Recovery
Return option is enabled (see below, the modem will automatically exit the Auto-
Recovery mode when the leased line conditions are satisfactory. Any normal disconnects (such as loss of carrier or line current) may also disconnect the dial connections and return communication to the leased line.
To ensure the proper disconnect capabilities for Leased Line Auto
Recovery mode, both of the following disconnect options must be enabled on both modems: line current disconnect (CURRENT
DISC’T screen) and carrier disconnect (CARRIER DISC’T).
To manually exit the Leased Line
Auto-Recovery mode and return to leased-line operation, select DIAL from MAIN MENU screen 1, and then select HANGUP for the
AUTO-DIAL screen.
85
MODEM 32144
4.9.3 L
EASED
L
INE
A
UTO
-R
ECOVERY
O
PTIONS
Three options allow you to specify the criteria the modem will use in determining when to enter and exit the Leased Line Auto-Recovery mode:
Leased Line Auto-Recovery Select
(Select)
This option determines the type of
Leased Line Auto-Recovery desired. “DIAL IF BAD>(1, 2, 3, or
4) min” or “DIAL IF BAD>30 s
(seconds)” means dial backup will occur if bad line conditions are present for the specified (selected) time period. To disable the Leased
Line Auto Recovery, select NO
AUTO RECOVERY. A sixth option,
Manual Recovery, is discussed below.
NOTE
If “DIAL IF BAD>(1, 2, 3, or 4
4) min (or 30 s)” is selected, the Select option settings of the answer and originate units must be the same.
Manual Recovery
If both modems are set for
MANUAL RECOVERY, the originate unit can be used to autodial the number stored via the
PHONE screen without having to change the LINE TYPE setting on either unit. To autodial, access the
AUTO-DIAL screen and select
DIAL. To return to the leased line, select HANGUP from the AUTO-
DIAL screen.
Return from Leased Line Auto-Recovery
(RETN)
This option determines the criteria for exiting Leased Line Auto-
Recovery mode.
“RETURN IF GOOD>(10, 40, 60, or 120)s” means the modem will automatically exit the Leased Line
Auto-Recovery mode when it tests and finds the leased line in good condition for more than the time period specified (10, 40, 60, or 120 s). If the Return option is set to
OFF, the modem will stay in the
Auto-Recovery mode indefinitely, unless you select HANGUP from the AUTO-DIAL screen or unless a loss of line current or other normal disconnect occurs. Either event will return communication to the leased line.
NOTE
The Return option setting must be the same on both communicating units.
86
Test Interval (Test)
If the Return option has been enabled (10, 40, 60, or 120 s), the
Test Interval selections control how frequently the modem will test the leased line conditions to determine if exit from the Leased Line Auto-
Recovery mode is desirable (based on the criteria selected for return from Auto-Recovery). The modem can be set to test every 10, 20, 40, or 60 minutes.
NOTE
The Test option setting must be the same on both units.
4.10 Modem Security Operation
NOTE
Security features described in this manual provide a deterrent to unauthorized access. No communications system can be made perfectly secure.
Two types of security operation are available to screen incoming calls:
• Automatic password protection
(APP). Users do not have to enter a password, but both modems must be correctly configured to exchange the same password (as part of a security handshake), or they will not be able to connect.
CHAPTER 4: General Operation and Special Features
• Manual-response password protection (MPP). Remote users attempting to connect to the modem are required to enter a password. Incoming calls are accepted only if the user enters a valid password.
4.11 Automatic Password Protection
(APP)
The modem can be configured for two types of APP:
• APP without callback—The modem can be configured so that each time it receives a connect request from another modem, it automatically employs a security handshake that includes a user-assigned password. Connect requests will be accepted only from modems that have been programmed with the same password. APP without callback functions in any operating mode that uses trellis coding (normally 72, 090 bps and above).
• APP with callback—This type of password protection is the same as described above, except that the answer modem connects with the originating modem by calling it back. The connection can only be made if both modems are preprogrammed with the same password and if the answer modem is preprogrammed with the number of the originating modem (the callback phone number). APP with callback is for dialup applications only
(synchronous or asynchronous).
87
MODEM 32144
With either type of APP, each incoming call is passwordprotected, yet there is no need for user to enter a password. Passwords are preprogrammed, sent over the modems’ auxiliary channel, and automatically compared by the modem. The only time manual intervention is required is when the password (and callback number, if used) is established or changed.
If desired, the password can be disabled. This allows the modem to accept calls from modems that have not been programmed to send the correct password—including modems that do not support the modem security handshake.
The automatically invoked password (and callback number, if used) is established or changed.
If desired, the password can be disabled. This allows the modem to accept calls from modems that have not been programmed to send the correct password—including modems that do not support the modem security handshake.
The automatically invoked password (and callback phone number, if used) is stored in nonvolatile memory, so it will be maintained if the unit loses power or upon a quick (soft) reset.
However, a factory reset will clear the automatic password (and callback number, if used) from memory.
NOTE
When APP is used, the modem will not fall back to speeds lower than 7200 bps.
After a connection has been established using the security handshake and automatic password
(and callback phone number, if used), a flashing “S” will be displayed in the top left corner of the EIA status screen to indicate that a secure connection has been made. (If the modem is in a dial mode, “S”—and “D” for dial line occupied—will flash alternately.)
The APP process is summarized below. Answer modem refers to the local modem; originating modem refers to a remote modem; when it calls or attempts to call the answer modem.
• An originating modem calls the answer modem.
• The originating modem automatically sends the preprogrammed password via the security handshake.
• If the answer modem is configured for APP without callback, it confirms the password and connects.
For APP without callback, this is the end of the process. For APP with callback, the process continues:
88
CHAPTER 4: General Operation and Special Features
• Both modems go on-hook.
• The answer modem calls the originating modem back.
• Modems exchange security handshake (again) and connect.
4.12 Configuring Modems for APP
The procedures for configuring the originating and answer modems for both types of APP are summarized below and then explained in detail in the subsequent sections.
4.12.1 APP W
ITHOUT
C
ALLBACK
• Enter the same password in the front panel password screen
(on the LCD) of the originating modem and answer modem.
4.12.2 APP W
ITH
C
ALLBACK
• Enter a password in the front panel password screen of the originating modem (the user password).
• A password must be entered in the front-panel password screen of the answer modem (the master password). Any password will do (even a single character), except that it should not be the same as the user password, and it should not be the same as any other password stored in the answer modem’s memory (for APP or MPP).
APP with callback will not function if the master password is removed.
• Use the Hayes AT &Z command to store the user password and callback phone number in the answer modem’s memory.
4.12.3 P
ASSWORD
S
CREENS
For either type of APP, a password must be preprogrammed through the PASSWORD screen of both the answer and originating modems, as explained below.
For APP without callback, use the same password on both modems.
For APP with callback, do not use the same password—see Section
4.12.2
.
Establishing or Changing the
Automatic Password
The automatic password can be changed (or initially established) using the front panel password screens shown below. These screens are accessed via the PASSWORD screen.
Change-Password Screen:
DEC SKIP INC
89
MODEM 32144
Clear-Password Confirmation
Screen:
CONFIRM
NOTE
The change-password and clear password confirmation screens will not be displayed if the front panel is disabled.
To change or establish the automatic password, select
CHANGE from the PASSWORD screen. The change-password screen will be displayed. If a password has been previously programmed, it will be displayed.
Use the right and left arrow pushbuttons to move from one character position to the next.
The character at the current cursor location will flash on and off. Use pushbutton 1 to change the character at the current cursor location to the next descending character or pushbutton 3 to change it to the next ascending character. Use pushbutton 2 to skip through groups of characters
(ascending). Use the arrow pushbuttons to move on to the next character to be changed.
4.12.4 V
ALID
P
ASSWORD
C
HARACTERS
Valid password characters are A through Z (upper case or lower case), 0 through 9 and the following symbols: ! " # $ % & ' ( )
* + , - . / Spaces function as valid password characters; therefore, a password that includes spaces will only match another password with spaces in the same positions. Note, however, that a space in the first character position will disable the password. When the LCD cursor is in the same position as a space, the space is shown on the LCD as a flashing black box; otherwise, spaces appear as void spaces.
The following paragraph applies only to the user password entered in the originating modem when configuring modems for APP with callback:
The only valid password characters are capital A through Z.
If any characters outside this range are used, callback operation will not function. No spaces between the letters are allowed, except that the user password (as entered on the front panel) must end with a space.
90
CHAPTER 4: General Operation and Special Features
Entering the Selected Password
When the new password is correctly displayed on the LCD, press the
ENT pushbutton. This will cause the new password to take effect.
The modems are configured for APP without callback when matching passwords are entered in the front panel password screens of both modems.
4.12.5 APP
WITH
C
ALLBACK
: S
TORING
THE
P
ASSWORD WITH
C
ALLBACK
N
UMBER
If you have followed these instructions to this point, the user password will be stored in the front-panel password screen of the originating modem, and a different password (the master password) will be stored in the front-panel password screen of the originating modem, and a different password
(the master password) will be stored in the front panel password screen of the answer modem. (The master password should be different from the user password, because it can be used to access the answer modem directly, without callback. The master password allows access for troubleshooting from a remote site.)
The final step in configuring the modems for APP with callback is to store the user password in the answer modem’s memory, along with the callback phone number, as explained below.
From the DTE, use the Hayes AT
&Z command and /S (a special command) to store the user password (capital A through Z, no spaces) and callback number in a specific memory location. Memory locations 0 through 9 may be used.
The following example shows how to store a user password and callback number in memory location 3:
Enter AT &Z3=T5551212/SGRAPE
The callback number (phone number of the originating modem) in this example is 555-1212 (with T used to specify tone dialing). The user password is GRAPE. (When the user password is entered on the front panel password screen of the originating modem, a space is required at the end. Do not use a space at the end when storing the password with the AT &Z command.)
A remote user can now call from the specified callback number, 555-
1212. The originating modem will send the preprogrammed password
GRAPE as part of the security handshake. The answer modem will confirm the password and connect by calling the originating modem back.
4.13 Disabling APP
4.13.1 T
EMPORARILY
D
ISABLING
APP
To temporarily disable either type of APP, select CHANGE from the
91
MODEM 32144
PASSWORD screen. The changepassword screen will be displayed.
With the cursor in the first character position, press pushbutton 2 (SKIP) until a space appears (flashing ■). Then press
ENT. The password will be disabled.
With the password disabled, the answer modem can connect to another modem that is not equipped to use or is not configured to use APP (for example, one where a password has not been entered in the front-panel change-password screen). However, it will not be able to connect to a modem that is programmed with a password for APP without callback.
To restore the password, replace the space with the first character of the password and press ENT.
4.13.2 C
LEARING THE
P
ASSWORD
To clear the front-panel password from memory, select CLEAR from the PASSWORD screen. The clearpassword confirmation screen will be displayed. Press pushbutton 2 to confirm that you want to clear the password.
If no password is stored, the modem will be able to connect to other modems that are not equipped to use or are not configured to use an automatic password (APP). To temporarily disable the automatic password, see the previous section.
4.14 Manual-Response Password
Protection (MPP)
The modem can be configured for two types of MPP:
• MPP without callback—The modem will pass a connection on to the DTE interface only after it receives a valid password.
• MPP with callback—The answer modem will call back an authorized user after he or she enters a valid password.
Both types of security operation provide security on incoming calls by requiring remote user to manually enter a valid password.
In addition, access to Hayescompatible commands for viewing and storing phone numbers is password protected.
The MPP process is summarized below.
• A remote (originating) modem calls the local (answer) modem.
• Local modem answers.
• Remote user sends carriage return [CR].
• Answer modem confirms password and grants access (if programmed for MPP without callback) or initiates security callback (if programmed for
MPP with callback).
92
CHAPTER 4: General Operation and Special Features
4.15 Commands for Enabling MPP
Modem configuration for MPP is controlled from the DTE by a special set of password commands.
These commands are implemented by using the Hayes AT &Z command to store them in memory. If an administrative password has been implemented, the front panel will be disabled and the AT &Z command will not function until it (the AT &Z command) is unlocked. (The procedure for unlocking the AT
&Z command is explained in
Section 41.6, How to Use Password
Commands
.
The modem incorporates 10 memory locations for storing telephone numbers, passwords, and/or the MPP password commands listed in Table 4-4. To implement a security command, use the Hayes AT &Z command to store the command in a specific memory location. The password commands are listed in Table 4-4 and explained in detail in the sections that follow.
Table 4-4. Password Commands for MPP.
Command Function Example Mem. loc.
/A
/P
/U
Set/change administrative password; /ASECURITY 1 password-protects use of certain
Hayes commands.
/PYELLOW2-9 Set password for—
MPP without callback or
MPP with callback
User-defined text string. Used to
4443535/PRED
/UHELLP 0 send a response to the remote terminal user after a valid password is received.
1 Command string stored using AT &Z command.
2 Each command will function only in the listed memory locations.
93
MODEM 32144
Rules for Using Passwords and
Password Commands (MPP)
• Memory locations 0 and 2-9 may be used for storing phone numbers; locations 2-9 may be used to store passwords.
• The entire command string, including the AT &Z command, cannot exceed
40 characters.
Passwords
• Passwords and commands may be entered in capitals or lowercase letters. (However, they will be stored and subsequently displayed as capitals.) Do not include number or spaces.
• For MPP without callback, / must be the first character in a storage location; for MPP with callback operation, a phone number must be listed first in a storage location.
• Special characters (! @ ?, etc.) may be used for passwords entered via the DTE interface, but these characters cannot be entered via the modem’s front panel.
• A phone number cannot be stored after /.
Commands
• Only one command (/A, /P, or /U) can be stored in each memory location.
• Do not leave a space after a command.
• When using the /U command, do not include spaces or control characters in the specified text string.
4.16 How to Use Password
Commands
To Establish or Change the
Administrative Password:
For greatest security, an administrative password should be used. If implemented, the administrative password controls access to the Hayes-compatible &V and &Z commands. These commands are required to view or modify the modem’s security configuration (as explained in the following sections).
To establish or change an administrative password:
Enter AT &Z1=/ASECURITY but replace SECURITY with the password of your choice.
94
CHAPTER 4: General Operation and Special Features
NOTE
The administrative password may only be stored in memory location 1. The command line, including AT
&Z1=, cannot exceed 40 characters.
To Unlock the &V and &Z
Commands:
If an administrative password has been implemented, the Hayescompatible &V and &Z commands cannot be accessed unless they are first unlocked using the current administrative password. (&V is used to view the active modem configuration, stored phone numbers, password commands and passwords; &Z is used to store phone numbers, password commands, and passwords). To unlock the &V and &Z commands, enter
AT &Z=/ASECURITY or substitute other current password in place of SECURITY.
The &V and &Z commands will now be accessible.
To re-lock the &V and &Z commands, enter AT Z. The DTE will respond with OK, and the &V or &Z commands will not function until they are unlocked.
To Program MPP without Callback
Operation
Use the commands AT &Z and /P to specify the password to be used for MPP without callback operation. The following example programs memory location 5 for
MPP without callback:
Enter AT &Z5=/PYELLOW
The password is YELLOW. After the modems connect, the remote user presses the DTE Enter key once. The DTE will then prompt the user to enter the assigned password by displaying the
PASSWORD? query. If the user enters the correct password,
YELLOW, the call will be connected.
NOTE
MPP Passwords may only be stored in memory locations
2 through 9.
To Program MPP with Callback
Operation:
Use the commands AT &Z and /P to specify the callback phone number and password to be used.
The following example programs memory location 3 for callback operation:
Enter AT
&Z3=T5551212/PCANARY
95
MODEM 32144
The callback number in this example is 555-1212 (with T used to specify tone dialing); the password is CANARY. A remote user can now call from the specified callback number, 555-
1212. After the modems connect, the remote user presses the DTE
Enter key once. The DTE will then prompt the user to enter the assigned password by displaying the
PASSWORD? query. Upon receipt of the correct password, CANARY, the local modem will call back the remote user at 555-1212. Once this connection is established, data may pass freely.
NOTE
MPP passwords and call back numbers may only be stored in memory locations
2 through 9.
To Program a Response to a Correct
Password:
Enter AT &Z0=/UCONNECTED but replace CONNECTED with the message of your choice.
The DTE will respond with the specified message when the modem receives a correct password.
NOTE
The /U command and message can only be stored in memory location 0.
96
CHAPTER 5: Hayes Emulation Mode
5. Hayes Emulation Mode
For easy reference, the following tables appear consecutively at the end of this chapter:
• Hayes-Compatible Commands
(Table 5-1)
• Hayes Mode Result Codes
(Table 5-2)
• S Register Functions (Table 5-3)
5.1 Hayes Mode Autodialer
When the Hayes emulation mode is enabled, the modem emulates a
Hayes autodialer and functions much like a Hayes modem.
Commands are issued from the computer keyboard (or other
DTE), and the modem is compatible with software written to drive a Hayes-style “AT” command set.
5.1.1 E
NABLING THE
H
AYES
M
ODE
A
UTODIALER
The Hayes mode autodialer can be enabled in either of two ways—by using the Quick Setup feature or by selecting HAYES from the DIALER screen:
• QUICK SETUP. If you select 2-
Wire Dial (Hayes) by using the
Quick Setup feature, the Hayes mode autodialer will be enabled, and all modem options will be automatically set to a preset configuration suitable for typical Hayes mode applications. To select the
2-wire dial Hayes Quick Setup, access QUICK SETUP screen 1 on the LCD and press pushbutton 2.
• DIALER MODE. If you enabled the Hayes mode autodialer using the Dialer Mode option, no other options will be changed. To enable the autodialer this way, select
DIALER from SETUP screen 2.
Then select HAYES from the
DIALER screen.
5.1.2 C
OMMAND
G
UIDELINES
The following guidelines for using
Hayes-compatible AT commands also provide a summary of the fundamentals of Hayes mode autodialer operation.
NOTE
Although carriage returns are not shown in the examples in this chapter, a carriage return is required at the end of each command line.
97
MODEM 32144
• ESCAPE SEQUENCE (+++).
The escape sequence causes the modem to escape from the data transfer mode so it can interpret commands.
(Alternate characters for the escape sequence can be assigned via S register S2.)
• ATTENTION CODE. AT, the attention code, must begin all command lines. There are a few exceptions—but only a few.
• COMMAND SEQUENCE. For dialing, a command line begins with AT and is followed by D and the phone number. Other commands should be placed before the dial command—or after the dial command if it is terminated with a semicolon— for example:
AT M2 V1 D 555-1212; S2=1O
This instructs the modem to:
Keep speaker on (M2), send word result codes (V1), dial (D) 555-
1212, end dial command (;), set register 2 to 1 (S2=1), and go online and wait for carrier (O).
Characters not in the command set are ignored during the dial command. For this reason, punctuation or spaces can be included in the telephone number to make it easier to read:
AT DT 9,(212)555-1234 or AT DT
9, 212 555 1234
• A/ COMMAND. Repeats the commands included in the previous command line.
Because the AT is also repeated, no AT is needed to begin this command, nor is a carriage return needed. A/ is useful for redialing a telephone number.
• BACKSPACE KEY. The backspace key deletes the last character entered (provided there is no intervening carriage return) and can be used for simple editing.
• CARRIAGE RETURN [CR]. A carriage return is required at the end of a command line.
The modem will not execute a command without it. A carriage return is sent from the DTE keyboards; a period, which may be entered via the modem’s front panel (PHONE LCD screen), has the same function.
(On most keyboards, the carriage return [CR] key is labeled “Enter” or “Return.”)
• DIAL COMMAND
MODIFIERS. Several modifiers can be used with the basic D
(dial) command to alter dialing operations. These modifiers are listed and explained briefly below—they are explained in detail in Section 5.4
98
Dial command modifiers:
L—Links a phone number to another number to be dialed as an alternate.
P—Sets pulse-dialing mode.
S=m—Dial number stored at memory location m.
T—Sets tone-dialing mode.
W or : (colon)—Pause for 2 seconds.
, (comma)—Pause for 2 seconds.
; (semicolon)—Return to command state after dialing.
@—Wait for silence.
! (exclamation)—Flash hook
With few exceptions, dial command modifiers will function only if they are used in a command line with the D command or included in a stored number. A carriage return of period must be used at the end of a dial string. An example of a command line with two dial modifiers is:
AT DT 9,555-1212
The modifier T instructs the modem to tone dial, and the comma instructs it to pause after dialing 9 before dialing the remaining digits.
CHAPTER 5: Hayes Emulation Mode
MISSING PARAMETER. A missing parameter is interpreted as a zero. For example, the E command (echo) can be sent as either E0 or E1, but if an E alone is sent, the modem will interpret it as if an E0 was sent.
COMMAND BUFFER. The command buffer can hold a maximum of 40 characters. If the command line exceeds 40 characters, the modem refuses to execute any portion of the command line and sends an error message. The AT at the beginning of the command line, control characters, and spaces do not take up space in the command buffer.
Punctuation (except for spaces) does take up space in the command buffer.
5.2 Result Codes
Result codes (Table 5-2) are messages sent by the modem to the
DTE monitor in response to your commands. Result code options are selected using the V and X commands, as explained below.
Result codes may be words (V1 command) or digits (V0). Word codes are preceded and followed by a carriage return, line feed sequence. Digit codes are only followed by a carriage return.
99
MODEM 32144
Result codes 0-4 comprise the basic result code set: OK,
CONNECT, RING, NO CARRIER, and ERROR. Codes 5-43 provide additional response information, as explained in Table 5-2. Various combinations of these codes can be enabled or disabled by using the X command and its four parameters, as explained later under X—
SELECT RESULT CODE.
NOTE
With the default Hayes mode settings in effect, the modem transmits result codes to the DTE. In some installations, this may cause undesirable interaction with the attached DTE. If such interaction occurs, result codes for incoming calls should be suppressed
(using the command AT Q2).
5.3 Transmission Speed
This section applies only to connections made without error correction or buffering (V.42/V.42
bis, MNP and Buffer Mode options).
Transmission speed is governed by the speed of the system with which you wish to communicate.
You must set the transmission speed of your computer by setting a switch in the hardware or by issuing a software command. (Refer to your computer documentation.)
When the modem originates a call, it automatically detects and adjusts to the transmission speed set when the communication port was initialized.
When answering a call, the modem determines the transmission speed from the carrier signal of the originating modem.
Change the speed (baud) setting of your equipment to match that of the remote system. Otherwise, unintelligible data will appear on your screen. (Depending on the parameter used with the X command, the speed will be indicated by the CONNECT response code.)
Autobaud
When a call is originated in Hayes mode, the AT attention code causes the modem to autobaud.
The speed at which the modem autobauds defines the speed limit for subsequent connections and overrides any front panel Speed
Limit or DTE Speed settings. If the unit is not autobauded, the default interface rate is 38,400 bps.
NOTE
If AT is entered at one speed and followed by a carriage return [CR] at another speed, the modem will not recognize any further commands until a [CR] is entered at the same speed of the AT.
100
CHAPTER 5: Hayes Emulation Mode
5.4 Compatible Commands
All that can be used with the modem are listed in Table 5-1
(near the end of the chapter.)
More detailed information is provided below for selected Hayes commands—particularly those used to answer and originate calls, and other commonly used commands. For Hayes commands that control modem options, additional information on options may be found in Chapter 5.
Commands are listed in alphabetical order in this section and in Table 5-1.
For most commands there are parameters—numerical values used with the commands that specify the function of the command. For example, the command L controls the modem’s speaker volume. L2 sets the volume to medium. The default value is a predetermined value which is in effect the first time the modem is powered up or when a reset command is given.
The possible parameters and default value for each command are shown in Table 5-1.
A—ANSWER. The A command immediately puts the modem into the answer mode. The modem will not execute any command entered in the command line after A.
The A command is used to manually answer an incoming call or to transfer a call between two individuals to a communication between their computers: One person enters AT A while the other enters AT D.
A/-REPEAT PREVIOUS
COMMAND. A/ is most commonly used to redial a telephone number that results in a busy signal. The AT prefix is not used with A/, and no carriage return is required.
Commands are available for repetition in the command buffer only until AT is entered or power to the unit is turned off. A/ will not work following an AT or power
OFF-power ON.
D-ORIGINATE MODE FOR
DIALING. The modem dials the number that follows and attempts to go on-line. The dial command D is followed by—
• A telephone number to be dialed, or
• A string consisting of a phone number and dial command modifiers (e.g., T, P, and ;).
An example of the D command is AT D3331234.
101
MODEM 32144
In response to this command, the modem dials the telephone number 333-1234, and then waits for a carrier tone from the distant modem (default wait time, 30 seconds). If the modem is able to establish a call, it gives a
CONNECT result code, indicating that it is on-line. If it cannot connect, it will use a different result code , such as NO CARRIER, BUSY, or NO DIALTONE.
The characters that can be dialed are 0 through 9, A, B, C, D, #, and
*.
The dial command modifiers are listed in the preceding Command
Guidelines section.
AT D—the dial command without a telephone number causes the modem to pick up the telephone line without dialing a number.
DS—DIAL STORED NUMBER.
The DS command instructs the modem to dial a phone number or dial string previously stored using the &Z command. The syntax is
DS=m, where m specifies the memory location where the number to be dialed will be stored.
Up to ten numbers may be stored in memory locations 0-9. S=m may be placed anywhere in the dial string for example, AT D2345S=2 will dial 2345 and the number stored in memory location 2.
H—TELEPHONE SWITCH
HOOK. The H command on-hook) is used to terminate a call. (Onhook corresponds to off-line.)
H may also be used to alternate between voice and data transmission during the same call
(if your communication software supports this capability).
The H1 command (off-hook) activates the telephone line relay, causing a dial tone to be sent
(after a 2-second delay). For most purposes, this command is not necessary, since the switch hook is automatically activated when the modem originates or answers a call.
L—LINK. The L dial modifier is used to link one phone number to another so that one may be designated as an alternate number to be dialed if a connection cannot be made to a primary number. The
L parameter must be used after a phone number, and prior to a carriage return or period. A number is used after L to specify
;the memory address (0-9) that contains the number to be linked to the first number:
AT D 555-1212 L5
102
NOTE
L may also be used in V.25
bis mode with the CRN command (instead of AT D), in Dumb mode and in 208 operation. In Dumb mode or
208 operation, L is stored via the PHONE screen. In all cases, L is used the same way and has the same function as described here
(except that AT D is not used.)
Two or more addresses may be linked in a cyclic fashion to alternate dialing until a connection is established.
Contents of memory location 0:
555-1212 L1
Contents of memory location 1:
444-1234 L2
Contents of memory location 2:
888-5555 L0
With the memory locations loaded as shown above, if the command AT DS=0 is issued, the autodialer will go to location 0 and dial the number stored there. If unable to connect, the L1 command stored in location 0 will direct the autodialer to dial the number in location 1. In similar fashion, the L2 stored in memory location 1 directs the autodialer to location 2 (assuming a connection cannot be made); and the L0 command stored in location 2 directs the autodialer back to location 0. The numbers will be
CHAPTER 5: Hayes Emulation Mode
dialed in a loop until a connection can be established or until 10 calls have been attempted.
O—FORCED ON-LINE. This command applies to asynchronous operation only. When the modem is on-line, you can return to the command state by entering the escape code (+++). After the desired command has been executed, use the O command to force the modem from the command state to the on-line state.
P—PULSE DIAL. The P command instructs the modem to pulse dial. It can be entered anywhere in the dialing string:
AT P5551212; or it can be entered alone, followed by a carriage return, AT P, in which case all subsequent telephone numbers will be pulse dialed. If the dial command does not specify which dialing mode to use, the modem defaults to the last mode specified.
S—MODIFY S REGISTER.
This command is used to write information to a specified S register. The syntax is Sr=n, where r is the number of the register to be modified and n is the value to be written to it; for example:
AT S7=30
103
MODEM 32144
This command would change the value of register S7 to 30. If you enter just =5, the autodialer will change the value of the last register used to 5. More information on S registers is included later in this chapter.
S?—READ S REGISTER. This command instructs the autodialer to read the contents of the specified S register. The syntax is
Sr?, where r specifies the register to be read. For example, S7? reads the value of register S7. The value is displayed on the computer or terminal monitor. If you enter ? by itself, the autodialer will display the value of the last register used; if = is entered by itself, the autodialer will display the number of the last register used (e.g., S2). For information on how to interpret S register values, see Table 5-3.
T—TONE DIALING. This command causes a telephone number in the dial command string to be dialed using tone signals. (See the P command above for additional information.)
W—WAIT FOR DIAL TONE.
The W command (or colon) is used in a dial string to instruct the modem to wait for a dial tone before proceeding. The wait time
(30 seconds by default) can be adjusted by changing the value in register S7. If no dial tone is detected within the specified time, the modem will hang up and give a
NO DIALTONE result code (if this result code is enabled by the X command).
Z—RECALL STORED USER
PROFILE. The Z command resets the modem and recalls a profile of the modem configuration settings previously saved using the &W command. The profile is designated as profile 0 or profile 1 when it is saved using the &W command.
,—PAUSE. A comma causes the modem to pause for 2 seconds (or time specified in register S8) before processing the next character in a dial string or command. This command is used to place an outside call through a
PBX switchboard, where 9 has to be dialed to gain outside access— the pause allows time for the dial tone to occur before the modem dials the number.
AT D9,3331234
Similarly, a comma may be used to cause the modem to wait for a second dial tone before beginning to dial a telephone number.
Multiple commas may be used to increase the pause time.
;—FORCED COMMAND STATE.
A semicolon placed at the end of a dial command causes the modem to return to the command state after dialing without disconnecting.
The following examples illustrate how the ; command is used:
104
CHAPTER 5: Hayes Emulation Mode
The first example is a banking transaction: The command AT
D333-1234; dials the bank’s phone number and returns the modem to the command state. After the OK prompt is displayed on the DTE, the command AT D T 0901# is entered. This transmits the identification number 0901 to the bank, and again returns the modem to the command state. An account number and other data may be transmitted in the same way.
The second example illustrates one method of autodialing: Enter a dial string that ends with a semicolon, for example, AT DT9,
3331234. During the ring signal or when the call is answered, pick up the phone and enter AT H. You may then use a telephone connected to the modem for voice communication.
@—WSAIT FOR SILENCE
BEFORE DIALING. The @ command is used to gain access to a system that does not provide a dial tone. It tells the modem to wait for 30 seconds or the time specified by a register S7 for one or more rings followed by 5 seconds of silence before processing the next symbol in the dial string.
!—INITIATE FLASH HOOK.
The ! command causes the modem to go on-hook for 1/2 second. This has the same effect as holding the switch-hook button on your telephone down for 1/2 second.
You may be able to use this command for transferring calls.
&F—RECALL FACTORY
CONFIGURATION. The &F command restores the modem to its original factory configuration, using data stored in ROM.
However, this change is not permanent. If the modem is turned off or reset, the recalled configuration will be replaced with the default stored profile. (See the
&Y command.)
&V—VIEW ACTIVE
CONFIGURATION, ETC. This command displays the active modem configuration, user profiles stored using the &W command, and phone numbers stored using the &Z command. When &V is invoked, the DTE displays the configuration commands last issued, including parameters used, and the values currently stored in the S registers. The &V command should be issued as the last command on a line.
&W—WRITE PROFILE TO
MEMORY. The &W command saves the storable parameters of the modem’s active configuration by writing the configuration profile to non-volatile memory. By selecting either &W0 or &W1, two different user profiles can be saved (profile 0 or 1). One of these profiles will be automatically restored whenever the modem is powered on or when the Z command is issued. (See the
&Y and Z commands.)
105
MODEM 32144
The &W command cannot be used to write changes to the user profiles if the modem front panel has been disabled by the Front
Panel Control option.
The parameters listed below cannot be stored—they are all set by changing S register values (as indicated in Table 5-3):
S1—Ring count
S2—Escape-sequence character
(ASCII 43)
S3—Carriage-return character
(ASCII 13)
S4—Line-feed character (ASCII
10)
S5—Backspace character (ASCII
08)
S6—Wait time before blind dialing
S7—Wait time for carrier/dial tone
S8—Pause duration (effected by comma)
S9—Carrier detect response time
S10—Delay: Lost carrier until hangup time
S11—DTMF tone duration
S12—Escape-sequence guard time
S25—DTR detection
When the &W command is used to save a configuration profile, stored phone numbers are not saved as part of the profile.
&Z—STORE TELEPHONE
NUMBER. The &Z command is used to store a telephone number that can be subsequently dialed using the DS (dial stored number) command. The syntax is &Zm=n, where m specifies the memory location where the phone number or dial string will be stored and n is the number or dial string to be stored. For example, AT &Z5=T1
(301) 555-1212 will store the specified number at memory location 5. Ten memory locations are available: 0-9.
(The &Z command is also used to store passwords, as explained in
Section 4, Security Operation
.)
For pulse dialing, digits 0 through 9 can be stored; for tone dialing, 0 through 9, A through D,
# and * can be stored. The dial command modifiers listed in the
Command Guidelines section can also be stored.
Each memory location can hold a maximum of 24 digits, although locations 1 through 9 will automatically expand to the next empty location if loaded with more than 24 digits. Even if a stored number is continued to another location, the maximum length is 36 characters. (Attempting to dial a dial string of more than 36 characters will result in an ERROR message.) A memory location cannot be used for storage unless it is empty. To delete an entry, enter
AT&Zm=, where m is the memory location number. Only location 0 can be accessed from the modem’s front panel (via the PHONE LCD screen).
106
CHAPTER 5: Hayes Emulation Mode
\S—VIEW STATUS OF V.42-
RELATED CONFIGURATION.
The \S command displays the active
V.42 error correction configuration, stored V.42 profiles, and certain other data not displayed by the &V command.
5.5 Registers
The modem includes 28 registers
(S0-S27) that can be used to control specific modem operations in Hayes mode only. Each register holds a value that serves as a specific operating instruction for the modem. Several of the S registers affect how the previously described commands will be executed.
The functions of the registers intended for user access are explained below and summarized in Table 5-3.
5.5.1 R
EADING AND
S
ETTING
R
EGISTERS
Use the S command to read the value of a register or to change its value.
To read the current value of a register, use the command S?, where the number of the register is specified between the S and the ?, as follows: S9?. The decimal value of the register contents will then be displayed. Multiple registers may be read. For example, if you wish to read the current value in registers
S0 and S7, enter
AT S0? S7?
A typical response might be
001,030, OK, meaning that the values stored in registers S0 and S7 are 1 and 30, respectively.
To set or change a parameter, use the command S=, where the number of the register follows S and a value between 0 and 255 (the range of values that can be assigned to the registers) follows the equal sign:
AT S0=5
This command will change the value stored in S0 to 5.
The S command can also be used without ? or = to point to a register that will be subsequently read from or written to without being specified. To illustrate this, if you enter
AT S7 a pointer is set to the address of register S7. As long as no other S command is entered, the register value can be requested at any time without specifying the number. If you enter AT? the modem displays the current value in the S7 register.
Similarly, if you enter AT=8 the modem will change the value in the S7 register to 8.
107
MODEM 32144
5.5.2 S R
EGISTER
F
UNCTIONS
This section describes the function of individual S registers.
Table 5-3
lists the range of possible parameters and the default value for each S register. Only S registers that are intended for user access are listed.
S0—RING TO ANSWER ON.
The value in this register determines on what ring (first, second, third, etc.) the modem will answer on. Setting S0 to 0 disables auto-answer.
S1—RING COUNT. Register S1 counts the number of ring signals for each incoming call. If more than 8 seconds have passed since the last ring, S1 is cleared to zero.
S2—ESCAPE CODE
CHARACTER. The escape code is effective for asynchronous operation only. Values greater than
127 will completely disable escape code detection and prevent you from issuing a hangup command.
S3—CARRIAGE RETURN.
Register S3 is effective for asynchronous operation only.
Normally, the ASCII carriage return value, 13, is used.
S4—LINE FEED. This register is effective for asynchronous operation only. The line-feed character follows the carriage return only when word result codes have been selected (command V1).
Line feed can be changed to a null but cannot be totally disabled.
S5—BACKSPACE. This register is effective for asynchronous operation only. The value in S5 defines the backspace character.
Do not use values between 33 and
126.
S6—BLIND DIALING WAIT
TIME. The value in S6 determines how long the modem will wait after picking up the telephone line
(going off-hook) before it begins to dial. If S6 is set for less than 2 seconds, the modem still waits 2 seconds before dialing. If the X2 to
X4 command is in effect, dial tone detection will be enabled and blind dialing will be disabled, meaning that the value in S6 will have no effect.
S7—CARRIER/DIAL TONE
WAIT TIME. This register controls two wait times—wait time for carrier and, if W is included in the dial string, wait time for dial tone
(or wait time for silence if @ is used).
S8—PAUSE TIME. The pause time effected by a comma in a dial string or other command line is controlled by register S8.
S9—CARRIER DETECT
RESPONSE TIME. Register S9 determines how long a carrier tone must be present for the modem to
108
CHAPTER 5: Hayes Emulation Mode
recognize the tone and indicate a carrier detect. (The time required for the absence of a carrier tone to be recognized is fixed at 0.5
second.)
S10—LOSS OF CARRIER
DELAY. The value in register S10 determines how long the delay will be from the occurrence of a loss of carrier until the modem hangs up the telephone line. A value of 255 disables the modem’s carrier disconnect option (and line current option), meaning that the modem will not hang up in the absence of carrier or line current.
S11—TONES. This register sets the spacing of tones used for dialing. The rate can be slowed by increasing the value of S11 to the maximum value, 255. This register has no effect on pulse dialing, which is fixed at 10 pulses per second.
S12—GUARD TIME. This register is effective for asynchronous operation only. The escape guard time delay is required immediately before and after entering the escape code; therefore, the three escape-code characters must be entered within the guard time delay of each other.
The unit for this register is 1/50 second (or 20 ms), meaning that the default value of 50 equals 1 second.
If the guard time is zero, timing will not be a factor at all. The three escape characters can occur with any timing relationship, but they must be consecutive. Be cautious when assigning small guard times, however. You may not be able to enter three characters fast enough, especially if the guard time is less than the time required to transmit one character at the current transmission rate.
S18—DIAGNOSTIC TIMER. The value in register S18 determines how long a diagnostic test will run.
For example, if S18 is set to 120, the test (activated by one of the &T commands) will run for 120 seconds. If S18 is set to zero, the default, the test timer will be disabled and the test will run indefinitely. To terminate a test when the test timer is disabled, use the command &T0 or reset the modem. Register S18 is set to zero on powerup or by the command
AT Z or AT S18=0.
S25—DELAY TO DTR. The effect of the value stored in register
S25 is dependent on the operating mode, as explained below.
Synchronous mode 1: A delay occurs after a call is established before the modem examines the state of DTR. The duration of this delay is the value specified in S25
(in seconds). This allows the operator time to disconnect the modem from an asynchronous data terminal and attach it to a synchronous terminal without forcing the modem back into the command state.
109
MODEM 32144
Synchronous modes 1, 2, and 3:
A change in DTR (ON or OFF) which lasts for less than the value in register S25 (in 1/100ths of a second) is ignored by the modem.
S26—RTS TO CTS DELAY
INTERVAL. This register affects synchronous operation only. With the command &R0 in effect, CTS is turned on in response to an OFFto-ON transition of RTS from the local DTE—after the delay specified by the value in register
S26 (but only if the modem is online and ready to receive synchronous data).
5.6 Saving Option Selections
Changes made to option settings will cease to be effective if power is removed from the modem or if a factory reset has occurred—unless the modem configuration (all option settings) is saved to nonvolatile memory. The storable parameters of the modem’s configuration can be saved to user profile 0 or 1 using the &W command (&W0 or &W1). Upon powerup, the modem will recall either profile 0 or profile 1, depending on which has been designated as the default profile.
(The modem is shipped from the factory with profile 0 as the default profile.)
As explained in the following sections, the modem is programmed to treat profile 0 and profile 1 differently. Use profile 0 for your standard configuration and make it the default profile
(&Y0). Profile 1 (optional) is intended to be used to store an alternate configuration (e.g., for an alternate application).
To view the contents of the user profiles, use the &V and \S commands.
User Profile 0
User profile 0 is linked to the modem’s front panel (i.e., selections made using the frontpanel LCD).
• If you make option changes using the front panel, the changes for options for which there are associated Hayes commands will be saved to profile 0 when you exit the
SETUP menu.
• If profile 0 is recalled as the active configuration, the LCD screens will reflect the profile 0 configuration.
• If profile 0 is changed by means of Hayes commands or via the
Summary Setup feature and then saved, the changes made will be reflected on the LCD and will be effective for all modes.
If you make option changes from the front panel but have not exited the SETUP menu, and then make option changes using Hayes
110
CHAPTER 5: Hayes Emulation Mode
commands and save them to profile 0 using the &W command, the changes made using Hayes commands and saved to profile 0 will override the front-panel selections.
A Quick Setup will overwrite most modem option settings.
However, certain option settings stored in user profile 0 are not altered by Quick Setup—unless you change the configuration from one
Quick Setup type to another. The following parameters in user profile 0 are not affected by a
Quick Setup of the same type:
Option settings set by the Hayes compatible commands E, F, Q, V,
X, &J, &L, &P, &M, &Q, &Z, and
\V; and S register values in registers
S18, S25, and S26. A factory reset will reset these parameters—and all others—to the factory-default settings.
User Profile 1
User profile 1 is not linked to the front panel.
• Option changes made from the front panel are not saved to profile 1. Profile 1 can be changed only by using Hayes commands or the Summary
Setup feature.
• If profile 1 is recalled as the active configuration, the LCD screens will not be affected.
(This means that when profile
1 is active, it is possible for the
LCD to display an option setting that does not reflect the setting currently in effect.)
• If profile 1 is changed by means of Hayes commands or via the
Summary Setup feature, the changes will not be reflected on the LCD and will only affect
Hayes mode operation.
If profile 1 is being used as the active configuration, the options marked with an asterisk (*) in
Table 5-1
should be controlled by using the AT commands listed in
Table
5-1
or by using the Summary Setup feature described in Appendix B.
When profile 1 is active, these options can be changed via the front panel LCD, but the changes will not be effective for Hayes mode operation. (However, if profile 0 is subsequently recalled as the active configuration, the changes will be effective at that time.)
5.7 Facsimile (Fax) Transmission
Fax operation is available in Hayes mode only. The modem supports fax classes 1 and 2. You can use your modem with a fax program to transmit and receive facsimile data.
5.8 Hayes Mode Reference Tables
Table 5-1
lists the Hayes compatible commands that can be used with the modem.
111
MODEM 32144
Table 5-1. Hayes Compatible Commands
Command Function/Explanation
B
B0
B1
C1
A
A/
D
DS
ANSWER No parameters.
REPEAT PREVIOUS COMMAND. No parameters.
BELL/CCITT COMPATIBILITY MODE*
Selects CCITT V.22 mode (2100 Hz).
Selects Bell 212A mode (2225 Hz).
Modem displays OK; command has no other effect. (This response—instead of ERROR— maintains a degree of compatibility with older modems that support this command.)
ORIGINATE MODE FOR DIALING. No parameters.
DIAL STORED NUMBER. Parameters are
0-9 (available memory locations).
E
E0
E1
F1
ECHO
No echo.
Echoes all characters back to terminal screen when using a full duplex terminal and in local command mode.
Modem displays OK. Command has no other effect—unless V.22bis/V.22/V.21/V.23 fallback operation has been enabled. (For details, see
H
H0
H1 or H2
Automatic Fallback in Chapter 4.)
TELEPHONE SWITCH HOOK
On-hook (hang up).
Off-hook.
Default settings (where applicable) are in bold face.
*If user profile is active, option can be controlled (for Hayes mode operation) only by given command or by using Summary Setup. Do not change via front panel (except via Summary Setup).
112
CHAPTER 5: Hayes Emulation Mode
Q
Q0
Q1
Q2
L3
M
M0
M1
I4
L
L0 or L1
L2
M2
M3
I2
I3
P
Table 5-1. Hayes Compatible Commands (continued)
Command
I
I0
I1
O
Function/Explanation
PRODUCT CODE OR CHECKSUM
Requests product code.
Requests checksum for the modem’s software.
(Only a portion of the checksum displayed via the front panel will be displayed, in decimal format.)
Requests verification of software checksum.
Requests the following for each EPROM
(programmable memory unit): chip, part and revision number; checksum.
Reserved.
SPEAKER VOLUME*
Low speaker volume.
Medium volume.
High volume.
SPEAKER CONTROL*
Speaker always OFF.
Speaker ON until carrier is detected.
Speaker always ON.
Speaker OFF during dialing; otherwise ON until carrier is detected.
FORCED ON-LINE. Forces modem to on-line state.
PULSE DIAL. No parameters, but the default is T (for tone dial).
SEND RESULT CODE
Send result codes.
Withhold result codes (quiet).
Withhold result codes for incoming calls only
(quiet answer).
113
MODEM 32144
T
V
V0
V1
W
X1
X2
Y
Y0
Y1
Z
Table 5-1. Hayes Compatible Commands (continued)
Command
Sn=v
Sn?
X
X0
X3
X4
Function/Explanation
MODIFY S REGISTER. n is the register to be modified; v is the value to be written.
READ S REGISTER. n is the register to be read.
TONE DIAL. No parameters.
WORD/DIGIT RESULT CODE
Result codes are transmitted as digits.
Result codes are transmitted as words.
WAIT FOR DIAL TONE No parameters, but default wait time (register S7) is 30 seconds.
SELECT RESULT CODE
Selects basic result codes, 0-4.
Modem will blind dial (without dial tone).
No speed indication; no busy or dial tone detect.
Selects result codes 0-6, 10, 11, 13, 14, 15, and
18.
Same as X1 except busy signal detect is enabled. Selects result codes 0-5, 7, 10, 11,
13, 14, 15, and 18.
Same as X1 except busy signal detect is enabled. Selects all result codes. Connection speed (up to 14,400 bps) indicated; busy signal and dial tone detect enabled.
Note: Result code 8 is independent of the X command; it is displayed only when the @ dial modifier is used.
LONG SPACE DISCONNECT*
Disables long space disconnect.
Enables long space disconnect.
RECALL STORED USER PROFILE
114
CHAPTER 5: Hayes Emulation Mode
&G
&G0
&G1
&G2
&J
Table 5-1. Hayes Compatible Commands (continued)
Command
Z0
Z1
, (comma)
; (semicolon)
@
! (exclamation)
&C
&C0
&C1
&C2
&D
&D0
&D1
&D2
&D3
&F
Function/Explanation
Resets modem and recalls stored user profile 0.
Resets modem and recalls stored user profile 1.
PAUSE. No parameters, but default pause time
(in register S8) is 2 seconds.
FORCED COMMAND STATE. No parameters.
WAIT FOR SILENCE BEFORE DIALING. No parameters, but default wait time (register S7) is
30 seconds.
INITIATE FLASH HOOK. No parameters.
DATA CARRIER DETECT CONTROL*
DCD always ON when DTR is present.
DCD ON only in the presence of suitable data.
DCD ON when DTR is present; then toggles off for 500 ms upon disconnect.
DATA TERMINAL READY CONTROL*
Ignore DTR.
Go on-hook, assume command state and disable auto-answer upon DTR loss.
Disconnect upon DTR loss.
Reinitialize upon DTR loss.
RECALL FACTORY CONFIGURATION
No parameters.
GUARD TONE CONTROL*
Guard tone disabled.
Enables 550-Hz guard tone.
Enables 1800-Hz guard tone.
Modem displays OK result code; command has no other effect. (The modem is configured for
A/A1 control or MI/MIC control via jumpers JP2 and JP3, as detailed in Appendix C.)
115
MODEM 32144
&R
&R0
&R1
&R2
&S
&S0
&S1
Table 5-1. Hayes Compatible Commands (continued)
Command
&L
&M
&P
&Q
&Q0
&Q1
&Q2
&Q3
&S2
Function/Explanation
Modem displays OK result code; command has no other effect. (The modem is configured for leased line or dialup line operation via the front-panel QUICK SETUP and/or LINE TYPE screens.)
Can be substituted for &Q.
Modem displays OK result code; command has no other effect. (The pulse dialing ratio is factory-set, depending on whether the modem is a US or international model.)
ASYNCHRONOUS/SYNCHRONOUS MODE
Asynchronous mode.
Synchronous mode 1—
Synchronous/asynchronous mode.
Synchronous mode 2—OFF-to-ON DTR causes the modem to automatically dial a stored number.
Synchronous mode 3—Synchronous mode with manual dial. (A manually dialed call will switch immediately to synchronous mode.)
RTS AND CTS OPTIONS*
CTS follows RTS.
CTS follows DTR from the DTE.
CTS is on while the modem is on-line.
DATA SET READY CONTROL*
DSR always on.
DSR operates on according to RS-232 specification.
Options DSR operation for a crossover connection.
116
CHAPTER 5: Hayes Emulation Mode
&T6
&T7
&T8
&V
&V0
Table 5-1. Hayes Compatible Commands (continued)
Command
&T
&T0
&T1
&T3
&T4
&T5
&V1
&W
&W0
&W1
&X
&X0
&X1
&X2
Function/Explanation
TEST COMMANDS
Terminates a test in progress.
&T0 must be the last command in a command line.
Initiates a local analog loopback test.
Initiates a local digital loopback test.
Allows the local modem to accept a request from the remote modem for a remote digital loopback test.
Prevents the modem from accepting a request from the remote modem for a remote digital loopback test self-test.
Initiates a remote digital loopback test.
Initiates a remote digital loopback test self-test.
Initiates a local analog loopback self-test.
VIEW ACTIVE CONFIGURATION, ETC.
Displays modem configuration, user profiles, and phone numbers stored in memory locations 0-5.
Displays all stored phone numbers (contents of memory locations 0-9).
WRITE PROFILE TO MEMORY
Saves storable configuration parameters as user profile 0.
Saves storable configuration parameters as user profile 1.
TRANSMITTER CLOCKING*
Selects internal clocking.
Selects external clocking.
Selects receive-mode (slaved) clocking.
117
MODEM 32144
\D0
\D1
\F
\F0
\C3
\C4
\C5
\D
\F1
\K
\K0
\K1
\A1
\B
\B0
\B1
\C
\C1
\C2
Table 5-1. Hayes Compatible Commands (continued)
Command
&Y
&Y0
&Y1
&Z
\A
\A0
Function/Explanation
DEFAULT USER PROFILE
Stored user profile 1 will be recalled on powerup.
Stored user profile 1 will be recalled on powerup.
STORE TELEPHONE NUMBER. Parameters
0-9 (available memory locations).
KEYBOARD ABORT (answer unit only)
Enables keyboard abort. When keyboard abort is enabled, pressing any key on the answer unit will abort handshaking (and thereby prevent a connection from being made).
Disables keyboard abort.
BUFFER MODE/SPEED CONVERSION* 1
Disables speed conversion.
Enables speed conversion
MNP CLASS (LIMIT)*1
Limits operation to MNP class 1.
Limits operation to MNP classes 1 and 2.
Limits operation to MNP classes 1 through 3.
Limits operation to MNP classes 1 through 4.
Limits operation to MNP classes 1 through 5.
DIALING MESSAGE
Disables ”DIALING” message.
Enables “DIALING” message.
MNP FLYBACK BUFFER*1
Enables flyback buffer.
Disables flyback buffer.
V.42 BREAK HANDLING*1
Selects normal break handling.
Selects destructive/expedited break handling.
118
\P
\P0
\P1
\P2
\Q
0
CHAPTER 5: Hayes Emulation Mode
\M1
\N
\N0
\N1
\N2
\N3
Table 5-1. Hayes-Compatible Commands (continued)
Command
\K2
\K3
\M
\M0
Function/Explanation
Selects non-destructive/expedited break handling.
Selects non-destructive/non-expedited break handling.
V.42 bis OPERATION*1
Enables V.42bis operation (error correction with data compression).
Disables V.42bis operation.
V.42 MODE*1
Disables error correction.
Enables mandatory mode for error correction.
Disables error correction.
Enables automatic mode for error correction.
1Option can be changed only when the modem is disconnected from the phone line.
V.42 PROTOCOL*1
Selects LAPM protocol only.
Selects MNP protocol only.
Selects LAPM/MNP protocol (MNP as alternate).
V.42 FLOW CONTROL*1
Two parameters may be used (e.g., \Q0,1;
\Q3,2, etc.).
First parameter specifies DCE-DTE flow; second (optional) specifies DTE-DCE flow control.
None (no flow control).
119
MODEM 32144
Table 5-1. Hayes-Compatible Commands (continued)
NOTE: DTE speed and parity are set automatically. Auto-answer is enabled or disabled by S register S0.
Command Function/Explanation
1
2
3
%E0
%E1
-L0
-L1
\S
\T
\T0
\Tn
\V
\V0
\V1
%V0
%V1
%V2
\X
\X0
\X1
CTS on/off or RTS on/off (CTS for DCE-DTE flow control, RTS for DTE-DCE).
DC1/DC2 flow control.
DC1/DC3 flow control (default for DCE-DTE and DTE-DCE).
Disables auto-retrain.
Enables auto-retrain.
Selects permissive transmit level.
Selects programmable transmit level.
VIEW STATUS OF V.42-RELATED
CONFIGURATION. No parameters.
LOAD INACTIVITY TIMER
Disables inactivity timer.
Sets inactivity timer to n minutes (where n=0 to 60).
V.42 RESULT CODES1
Activates regular V.42 result codes.
Activates extended V.42 result codes.
Switches from Hayes mode to V.25bis mode, asynchronous.
Switches to V.25bis mode, sync bit oriented
(HDLC).
Switches to V.25bis mode, synchronous character oriented.
V.42 PASS-THROUGH FLOW CONTROL*1
Enables pass-through flow control.
Disables pass-through flow control.
120
3
4
5
6
7
8
Digit code
0
1
2
CHAPTER 5: Hayes Emulation Mode
Table 5-2. Hayes Mode Result Codes
Word code
OK
Meaning
Command line executed without errors
CONNECT
RING
NO CARRIER
ERROR
CONNECT 1200
NO DIALTONE
BUSY
NO ANSWER
Carrier detected at 0-300, 1200, or
2400 bps (basic code set)
Ringing signal detected (in answer mode). (When the modem detects a ring, it sends a RING result code unless it is in the process of accepting a command. However, the modem will answer the call only if it is set for automatic answer or is given an A command.)
Carrier lost or never detected.
Error in command line, invalid command, command line exceeds 40 characters, or invalid character format.
Carrier detected at 1200 bps.
No dial tone detected.
Busy signal detected.
No period of silence detected. This code will appear only if @ (“wait for silence before dialing”) has been included in the dial string.
121
MODEM 32144
Table 5-2. Hayes Mode Result Codes (continued)
Digit code Word code Meaning
9
10
11
CONNECT 0600
CONNECT 2400
CONNECT 1275
Carrier detected at 600 bps.
Carrier detected at 2400 bps.
Modem is on-line in V.23 mode
(1200/75 bps).
Carrier detected at 7200 bps.
Carrier detected at 12,000 bps.
12
13
14
15
18
20
73
74
75
76
21
22
72
CONNECT 7200
CONNECT 12.0
CONNECT 14.4
CONNECT 4800
CONNECT 9600
LINKING
CONNECT 16.8
CONNECT 19.2
DIALING
CONNECT 21.6
CONNECT 24.0
CONNECT 26.4
CONNECT 28.8
Carrier detected at 14,400 bps.
Carrier detected at 4800 bps.
Carrier detected at 9600 bps.
Modem is dialing numbers that’ve been linked using the L (link) dial modifier.
Carrier detected at 16.8 Kbps.
Carrier detected at 19.2 Kbps.
Modem is dialing.
NOTE: Four additional word codes are “BUFFER,” “MNP,” “V42” and “V42bis” followed by the DTE interface speed. These codes indicate if the modem is in buffer, MNP, or LAPM (V.42/V.42 bis) mode. The corresponding digit codes and speeds they indicate are listed on the next page (with all speeds in bits per second).
Carrier detected at 21.6 Kbps.
Carrier detected at 24.0 Kbps.
Carrier detected at 26.4 Kbps.
Carrier detected at 28.8 Kbps.
122
CHAPTER 5: Hayes Emulation Mode
Table 5-2. Hayes Mode Result Codes (continued)
BUFFER
28-19200
MNP
36-19200
V42
44-19200
V42bis
55-38400
29-9600
30-4800
31-2400
32-1200
33-600
34-300
35-110
53-38400
64-57600
68-1800
77-115200
82-230400
37-9600
38-4800
39-2400
40-1200
41-600
42-300
43-100
54-38400
65-57600
69-1800
78-115200
83-230400
45-9600
46-4800
47-2400
48-1200
49-600
50-300
51-110
52-38400
66-57600
70-1800
79-115200
84-230400
56-19200
57-9600
58-4800
59-2400
60-1200
61-600
62-300
63-110
67-57600
71-1800
80-115200
85-230400
123
S2
S3
S4
S5
MODEM 32144
Table 5-3. S Register Functions (only registers intended for user access are listed)
Register
S0
Range
0-255
Units
rings
Default
1
Description
Ring to answer on
S1 0-255 rings 0
0-127
0-127
0-127
0-127
ASCII
ASCII
ASCII
ASCII
10
8
43
13
Counts the number of rings
Escape code character
Carriage return character
Line feed character
Backspace character
124
CHAPTER 5: Hayes Emulation Mode
Table 5-3. S Register Functions (only registers intended for user access are listed)
S6 2-255 sec 2
S7
S8
S9
S10
1-60
0-255
1-255
1-255 sec sec sec
30
2
6
1/10 sec 14
Wait time before blind dialing
Wait time for carrier or dial tone
Pause time for comma
Carrier detect response time
Delay time between loss of carrier and
“hang-up”
125
MODEM 32144
Table 5-3. S Register Functions (only registers intended for user access are listed)
Register
S11
Range
70-255
Units
ms
Default
70
Description
Tone spacing
S12
S18
S25
0-255
0-255
0-255
1/50 sec sec sec or
1/100 sec1
5
1/100 sec 0
50
0
Escape code guard time
Test timer
Delay to DTR
S26
S43
S44
S46
0-255 RTS-to-CTS delay
(half duplex)
Speed limit, maximum
Speed limit, minimum
CD level
S53 0-15 -dBm 0 Leased line transmit level
S61 DTE speed
1Depends on mode; see previous section, S25—Delay to DTR.
126
CHAPTER 6: V.25 bis Autodialer
6. V.25 bis Autodialer
For international compatibility, the modem can be configured to function as a V.25 bis autodialer.
In V.25 bis mode, the modem is compliant with CCITT
Recommendation V.25 bis, an internationally recognized standard for serial automatic call origination and answering.
The V.25 bis autodialer uses the dialing command set defined by the V.25 bis Recommendation. It allows you to store and dial phone numbers from the DTE in both synchronous and asynchronous applications. You can dial numbers directly or you can instruct the modem to automatically dial a previously stored number.
6.1 Enabling the V.25 bis Autodialer
The V.25bis autodialer can be enabled in either of two ways—by using the Quick Setup feature or by selecting one of the Dialer Mode options.
6.1.1 Q
UICK
S
ETUP
Three Quick Setup configurations are available for 2-wire dial V.25 bis operation. Selecting any of the three V.25 bis Quick Setups (via
QUICK on SETUP screen 1) enables the V.25 bis autodialer and causes all modem options to be automatically set to a preset configuration. Each V.25 bis Quick
Setup is suitable for a typical V.25
bis application, depending on the
DTE to be used.
To select a 2-wire dial V.25 bis
Quick Setup, access QUICK SETUP screen 2, 3, or 4 (for asynchronous; synchronous, character-oriented; or synchronous, bit-oriented operation, respectively) on the
LCD, and then press pushbutton 2.
After selecting the desired V.25 bis
Quick Setup configuration, you can reset individual options to suit your application, if desired, as explained in Chapter 3.
In accordance with the CCITT
V.25 bis Recommendation, the modem V.25 bis asynchronous
Quick Setup sets the character length to 10 bits, including 1 even parity bit. Both V.25 bis synchronous Quick Setups set the modem for odd parity. (For synchronous operation, the character-length option setting has no effect.)
127
MODEM 32144
6.1.2 2 = D
IALER
M
ODE
(DIAL V.25
BIS
S
CREEN
)
If you enable the V.25 bis autodialer using the Dialer Mode option, no other options will be changed. To enable the autodialer this way, select DIALER from
SETUP screen 2. Then press the right arrow pushbutton to go to the
DIAL V25 bis screen (screen 2).
Select the V.25 bis data protocol that is appropriate for the DTE to be used: asynchronous (Asyn); synchronous, character-oriented
(Syn_c); or synchronous, bitoriented (Syn_b).
6.1.3 DTR D
IALING IN
V.25
BIS
M
ODE
An alternative to using the V.25bis
CRS command to dial a stored number is to use the DTR dialing option. With DTR dialing enabled, the autodialer will dial the number stored in phone cell 0 when DTR goes high for at least 50 ms.
To enable V.25 bis DTR dialing, use the Summary Setup feature (as described in appendix ) to change the parameter for Penril/V25 bis
DTR dialing to 0. Do not select
DTR dialing via the front-panel
DIALER screen; this will not enable
DTR dialing for V.25 bis mode. The
Summary Setup Penril/V25 bis
DTR dialing option applies to either V.25 bis mode or Penril mode—whichever is enabled; therefore, for V.25 bis DTR dialing, the V.25 bis autodialer must be enabled.
6.2 V.25 bis Autodialer Commands
In asynchronous applications, V.25
bis commands are issued directly from the DTE keyboard or through communications software. In synchronous applications, the V.25
bis commands can be used to facilitate computer-controlled communications.
Punctuation and spaces may be used with V.25 bis commands for clarity, but they are not required.
If used, they will be ignored by the modem. One exception is the colon (:), which instructs the autodialer to wait for a dial tone.
The V.25 bis commands are described below and are summarized in Table 6-1. See Table
6-3
for explanation of the codes that may be displayed in response to commands.
CIC - CONNECT NEXT
INCOMING CALL. The CIC command instructs the autodialer to answer the next incoming call.
After the modem goes off hook, the modem will answer the next call only if auto-answer is enabled from the front panel.
128
CHAPTER 6: V.25 bis Autodialer
CRN - CALL REQUEST, NUMBER
PROVIDED. (Syntax: CRN
5557979) By using the CRN command, you can dial a number directly from the DTE keyboard.
Numbers from 0 through 9 can be dialed, and if tone dialing is enabled, the characters A, B, C, D,
# and * can also be dialed.
The dialing parameters listed in table -2 can be used with the CRN command to specify how or when a number should be dialed. For example, the command line CRN
:T3331234 instructs the autodialer to wait for a dial tone (:) and then tone dial (T) the number 333-1234.
CRS - CALL REQUEST, ADDRESS
PROVIDED. (Syntax: CRS 2) The
CRS command allows you to dial a stored number simply by specifying its memory address (phone cell).
In the example given above, the autodialer will dial the number stored in phone cell 2. The number must first be stored in the specified phone cell using the PRN command (Table 6-1).
DIC - DISREGARD INCOMING
CALLS. The DIC command instructs the autodialer not to answer incoming calls. The DIC command is canceled when the
CIC command is issued or the modem is reset. In the event of a reset, the modem will answer if auto-answer is enabled from the front panel.
PRN - PROGRAM NORMAL
(STORE NUMBER). (Syntax: PRN
1;5551212) The PRN command is used to store a number or dial string in a phone cell so it can be dialed later by specifying only the phone cell number. As shown above, PRN is followed by the phone cell number, a semicolon and the phone number to be stored. After a number is stored, it can be dialed using the CRS command. Any of the characters listed in Table 6-2 may be stored.
Ten phone cells (0-9) are available for phone number storage. Each cell can hold a maximum of 25 characters, although cells 1 through 9 will automatically expand to the next empty phone cell if loaded with more than 25 digits. Even if a stored number is continued to another cell, the maximum number of characters that can be stored is 36. You cannot store a number in a phone cell unless it is empty. To clear a cell, enter PRN and the phone cell number, without a phone number. Only cell 0 can be accessed from the modem’s front panel (via the
PHONE LCD screen).
129
MODEM 32144
RLN - REQUEST STORED
NUMBER(S). RLN can be used to request a list of all stored numbers or to show the number stored in a specific phone cell. RLN, used alone, requests a list of all stored numbers. The DTE display will show the stored numbers as follows:
LSN 0; 301 555 1234
LSN 1; 301 123 4567
LSN 2; 301 555 5555
(and so on through phone cell 9)
If a phone cell number is specified after RLN, e.g., RLN 5, the DTE display will show only the number stored in the specified phone cell.
How to Disconnect a Call
To disconnect a call locally, use your communication software to force DTR to go low, or select
HANGUP from the front-panel
AUTO-DIAL screen.
130
CHAPTER 6: V.25 bis Autodialer
Command
CIC
Table 6-1. V.25bis Autodialer Commands
Function
Connect next incoming call.
CRN n
CRSm
Call request—dial number (n) entered on DTE keyboard.
Call request—dial number stored in specified memory address (m).
Disregard incoming calls.
DIC
PRN m; n
RHA
Program normal—store number or dial string n in memory address m.
Switch to Hayes dialing mode (also resets modem configuration).
Request list of all stored numbers.
RLN
RLN m Request to see number stored at address m.
n represents a number to be dialed or stored (e.g., 5557979); m represents a memory address where a number is stored (0-9).
A comma (,) can be included in a dial string to effect a pause.
A colon (:) can be included to instruct the autodialer to wait for a dial tone before proceeding.
131
MODEM 32144
6.3 Dialing Parameters
Table 6-2 lists dialing parameters that may be used with the CRN command to modify dialing operations.
Table 6-2. V.25 bis Dialing Parameters
(Table also applies to Dumb mode and Bell 208 operation)
Characters that can be pulse or tone dialed: 0-9
Can only be tone dialed: A, B, C, D, #, and *
L
P
T
W or : (colon)
[CR] or .
(carriage return or period)
, (comma) or <
Links a phone number to another number to be dialed as an alternate when the primary number is busy or does not answer. See L—Link in Section 5.4.
Sets pulse dialing mode.
Sets tone dialing mode.
Wait 30 seconds for dial tone before proceeding.
Required at end of dial command line.
[CR] is sent from DTE keyboard.
Dumb/208 mode only: period has same function, but may be entered via the front panel (PHONE LCD screen).
Pause before processing next character in dial string.
132
CHAPTER 6: V.25 bis Autodialer
Table 6-2. V.25 bis Dialing Parameters
(Table also applies to Dumb mode and Bell 208 operation)
Characters that can be pulse or tone dialed: 0-9
Can only be tone dialed: A,B, C, D, # and *
@ Wait for silence.
! (exclamation) Flash hook
L, P, T, and W may be entered as upper or lowercase letters. Spaces or hyphens (-) may be used as separators for clarity; they will have no effect.
6.4 V.25 bis Result Codes
Table 6-3 explains the result codes, or responses that may be displayed on the DTE monitor in response to
V.25 bis commands.
133
MODEM 32144
Code
CFI AB
CFI CB
Table 6-3. V.25 bis Result Codes
Meaning Sent by—1
Call failure—call aborted because of loss of DTR or because HANGUP was selected from front-panel AUTO-DIAL screen.
ORG
Call failure because DCE is busy.
(Modem dialing or handshaking as a result of a front-panel dial request.)
ORG
CFI ET
CFI ND
Call failure because of busy signal.
(Engaged tone.)
ORG
Call failure—no dial tone. Modem did ORG not detect dial tone or line current during dialing or handshaking.
ORG CFI NSCall failure—call request specified an address that does not contain a stored number. (No stored number.)
CFI NT Call failure—no answer tone. Remote ORG unit answered but did not issue answer tone.
1Column 3 indicates which modem sends the result code. (ANS/ORG indicates answer and/or originate modem.)
A semicolon is used to separate parameters,. e.g., LSN 4;5559797.
134
CHAPTER 6: V.25 bis Autodialer
Code
CFI RT
Table 6-3. V.25bis Result Codes (continued)
Meaning
Call failure—ring tone. Ringback detected, but no answer.
Sent by—1
ORG
CNX
INC
Call connecting.
Incoming call.
ANS/ORG
ANS
INV CU Invalid—command unknown.
INV MSInvalid message (command) syntax.
ANS/ORG
INV PS Invalid parameter value. Specified parameters are out of range for command used.
ANS/ORG
LSN
VAL
List of stored numbers. LSN is followed by memory address, stored number, next memory address and stored number, etc.
Valid—command accepted; waiting for next command.
ANS/ORG
ANS/ORG
135
MODEM 32144
6.5 Message Format
The message format for V.25 bis
DTE-to-DCE communications is summarized below:
6.5.1 A
SYNCHRONOUS
MARK|MESSAGE|CR|LF|MARK
This format uses one start bit,
8-bit data units, and a 1-unit stop bit. The 8-bit data units are formed by a 7-bit IA5 character and an even parity bit.
6.5.2 S
YNCHRONOUS
, C
HARACTER
-
O
RIENTED
|SYN\SYN\STX|MESSAGE|ETX|
This format uses consecutive 8-bit data units formed by a 7-bit IA5 character and an odd parity bit.
136
CHAPTER 6: V.25 bis Autodialer
6.5.3 S
YNCHRONOUS
, B
IT
-O
RIENTED
||FLAG|ADDR|CTRL|MESSAGE|FCS|FLAG|
Consecutive 8-bit data units are used within the message and submitted to the HDLC framing
(zero insertion). The 8-bit data units are formed by a 7-bit IA5 character and an off parity bit.
137
MODEM 32144
7. Diagnostics
The troubleshooting information in this chapter applies to all modem applications (all dialup and leased-line modes), unless specifically stated otherwise.
For specific test procedures, turn to one of the following sections in this chapter:
• Section 7.8, Local Modem
Diagnostics
• Section 7.9, Remote Diagnostics
7.1 When and Why to Test
If you are experiencing communications difficulties, the overall objective in correcting the problem should be to specifically isolate the defective component in your communications system. This typically involves three steps:
Identifying the symptoms and scope of the problem, performing a physical inspection of all units and connections in the system and, finally, conducting diagnostic tests.
Very often the diagnostic testing capabilities of the modem can help identify the specific faulty component, whether it is the modem, the DTE or telephone line.
7.2 Symptoms and Scope of the
Problem
As a first step toward isolating the problem, carefully consider each of the following questions:
• When did the problem begin?
• What is malfunctioning? Try to isolate the component or components of your system that are malfunctioning.
• Has there been a recent change in the system?
• Has the modem been reconfigured?
You can quickly find out if the modem has been reconfigured by checking the checksum shown in the SUMMARY screen (accessed via
SETUP screen 6) and comparing it with the checksum displayed when the modem was operating properly—if you made a note of the previous checksum. If the checksum is different from the original checksum, one or more option settings have been changed.
If you previously recorded the number strings (i.e., option parameters) displayed in the setup screens accessed via the SUMMARY screen, you should be able to determine which option settings have been changed (by comparing the previous and current option parameters).
138
7.3 Physical Inspection
The next step in isolating a defective component is to inspect the system. If you have been able to trace the problem to a specific site, examine that site. Check the installation of the modem and
DTE. Are all cables in good condition and fully connected?
Are all components in the system receiving power? Inspect the system as thoroughly as possible.
7.4 Overview of Modem Diagnostics
Once you have identified the symptoms and conducted a physical inspection of the sites in question, you can use diagnostic monitoring and testing to further isolate the problem. The modem is equipped with diagnostic capabilities that will often enable the user to locate faults quickly and easily. The diagnostic features of the modem fall into two categories—local and remote— as listed below.
There are six types of local modem diagnostics:
• Analog loopback (ALB)
• Analog loopback self test
(ALBST)
• Analog loopback self test with errors (ST/E)
• External analog loopback
(ALBX)
CHAPTER 7: Diagnostics
• External analog loopback self test (ALXST)
• Digital loopback (DLB)
There are two types of remote diagnostics:
• Remote digital loopback (RDL)
• Remote digital loopback self test (RDLST)
The sequence in which diagnostic tests should be conducted depends upon the symptoms that have been identified as well as the availability of personnel at the remote site and external test equipment. The self test pattern generator and pattern detector built into the modem alleviates the requirement for external test equipment. With the non-self tests, either a standard
DTE or an external bit error rate test (BERT) is used to generate test data and compare it with received data.
Because more transmission errors occur at higher speeds on marginal transmission facilities, begin testing at 14.4 Kbps. If errors occur, reduce the speed and try again. If you cannot correct the problem, contact Technical
Support for assistance.
139
MODEM 32144
7.5 How to Select and Activate Tests
7.5.1 F
RONT
-P
ANEL
C
ONTROL
Tests are accessed and activated in the same way options are selected: by using the LCD and front-panel pushbuttons (as explained in
Chapter 3
). To find the LCD screen for a specific test, refer to the LCD flow chart (DIAGNOSTIC AND
CONTROL FUNCTIONS) included with this manual. Once you have accessed the screen for a specific test, press pushbutton 1 to begin the test (select ON). A test status screen will then be automatically displayed. To deactivate a test, press the ENT pushbutton and then pushbutton
3. (The ENT button cannot be used to exit the text screen until the test has been deactivated.)
NOTE
For valid test results, error correction must be disabled before diagnostic tests are run. To disable error correction, set the V.42
Mode option to OFF.
7.5.2 R
UNNING
T
ESTS IN
H
AYES
M
ODE
In Hayes emulation mode only, most of the diagnostic tests available on the modem can be activated via the DTE keyboard by using the &T commands listed in
Section 5.4
. The duration of a test can be set by assigning a value to register S18. For example, AT
S18=30 sets the test time to 30 seconds. The command &TO terminates a test. For further information, see Section 5.4.
7.5.3 R
EMOTE
T
EST
C
ONTROL
You can configure the modem to ignore or accept requests from remote modems to initiate tests on your modem. To access the remote test control option, select TEST from SETUP screen 4. Then select
RMT from the TEST OPTIONS screen. From the REMOTE TEST screen, select ENABLE to allow remote test initiation or DISABLE to refuse remote test requests.
7.6 Diagnostic Monitoring: Status
Screens
To obtain additional information about the status of the communications system, observe the status screen described in the following sections. To view these screens, push the ENT button until the EIA status screen appears. Use the right arrow pushbutton to advance to other status screens.
7.6.1 EIA S
TATUS
S
CREEN
The EIA status screen indicates the operational status of the modem as well as the condition of certain EIA
RS-232 leads. The abbreviations that may appear are identified below; however, typically, only a few of these abbreviations will be displayed during actual operation.
140
D TR MR RS CS TD
D=Dial line occupied
R=Ringing (R appears in same position as D.)
S=Connection secured by security handshake (S appears in same position as D. S and D may flash alternately.)
TR=Data Terminal Ready
MR=Data Set Ready
RS=Request to Send
CS=Clear to Send
TD=Transmit Data
9600, 4800, etc. = Data speed
(“idle”—meaning the modem is off-line—or H-01, H-14, etc., may also be displayed in the data speed position; see following text.)
TM=Test mode
ER=Error (poor signal quality)
CD=Carrier Detect
RD=Receive Data
CHAPTER 7: Diagnostics
Handshake Display
When two modems establish a connection, they engage in an exchange known as a handshake.
While a handshake is taking place, the modem displays several codes ranging from H-01 to H-28 in the lower left corner of the EIA status screen. A handshake typically lasts for up to 12 seconds and is accompanied by various audible tones.
Checksum Screens
By pressing pushbutton 1 while the
EIA status screen is displayed, you can access two checksum screens, one for the main checksum and one for the data pump transmitter and receiver checksums. These checksums provide data intended for use by servicing personnel. The checksum screens also show the software revision levels (which are also shown on the power-on screen).
7.6.2 O
THER
S
TATUS
S
CREENS
QUALITY SCREEN. The quality screen displays the quality of the received signal carrier as a numeric value and as a horizontal bar graph. A low numeric value indicates good signal quality. The best possible signal quality is indicated when the bar graph extends all the way to the right edge of the LCD.
141
MODEM 32144
LINE LEVELS SCREEN. This screen shows the preset level of the transmit signal (TX) and the measured level of the receive signal (RX).
The RX value is the approximate local receive level of the incoming signal. The range of measurement for RX is from 0 to –43 dBm in 1.5dBm increments. If the signal level is less than the carrier detect threshold, <CD will be displayed.
ECHO CHARACTERISTICS
SCREEN. This screen displays the characteristics of the echo portion of the receive signal. Specifically, it shows milliseconds of delay and the offset frequency in Hertz.
CHANNEL FREQUENCY
OFFSET. This screen displays the frequency offset of the receive signal in Hertz.
THROUGHPUT SCREEN. This screen functions only if error correction has been enabled. It shows the rate (in bits per second) at which characters are being accepted by the modem from the
DTE.
PACKET SCREEN. The packet screen functions only when error correction is enabled. It has three components, as explained next.
• SIZE. Shows size of data packets
(MNP) or blocks (V.42/V.42
bis) currently being transmitted. MNP uses
“shorter” packets to transmit through noisy lines and
“longer” packets (which allow greater throughput) when line conditions are good. The maximum MNP packet size is
256 characters (MNP classes 4 and 5) or 64 (MNP classes 1-3).
The block size for V.42/V.42 bis is fixed at 128 characters.
• TRANSMITTED (TX). Number of packets or blocks transmitted since the connection was established (or since counter reset).
• ERRORS (ER). Number of retransmissions (due to data errors) since the connection was established (or since the counter was reset).
To reset the TX and ER counters, press pushbutton 2 while the packet screen is displayed.
MODE AND RATE SCREEN.
This screen shows the following data:
• MODE. Below MODE, this screen indicates the errorcorrection status:
- NORMAL, Error correction and buffer mode are both inactive.
142
CHAPTER 7: Diagnostics
- V42, V.42 error correction
(LAPM) is active.
- V42 bis, V.42 bis error correction
(LAPM with data compression) is active.
- MNP 01 – MNP 05, MNP error correction is active.
- BUFFER, Buffer mode is active.
- OFFLINE, Modem is off-line.
• RATE. This screen shows the data rate of the DTE.
7.7 Rate Change Screen
If V.32bis mode and the Rate
Renegotiation Procedure (RRP) option are both enabled, the modem will automatically adjust during data transmission to a higher or lower data rate, depending on the receive signal quality. For diagnostic purposes, the RATE screen (accessed from screen 3 of the MAIN MENU) may be used to manually initiate speed renegotiation from the front panel, as explained below.
The RATE screen is displayed only if V.32 bis mode is enabled
(via Summary Setup, V.32 Mode option).
If you select DOWN from the
RATE screen, the modem will fall back to the next lower speed. If you select UP, the modem will fall forward to the next higher speed— if the signal quality is good enough.
The range within which the modem can fall forward or fall back is limited by the minimum and maximum rates set via the
Speed Limit option. After you select UP or DOWN, the LCD will automatically switch to the EIA status screen so you can see the result of the rate change request
(i.e., the current data rate, which is displayed in the lower left corner of the EIA status screen). However, if the local modem has reached the minimum or maximum speed, it will not switch to the EIA status screen.
NOTE
A request to increase the data rate may result in no change in the data rate if the signal quality is poor.
If you manually initiate speed renegotiation with RRP enabled, the modem will automatically renegotiate the speed (again) after receiving good signal quality for
4 seconds. If the originate modem attempts to negotiate a rate that is lower than the minimum rate setting of the answer modem, the answer modem will disconnect
(GSTN cleardown).
143
MODEM 32144
7.8 Local Modem Diagnostics
Local modem diagnostics are for testing the modem and its adjoining system. These tests are accessed from the main menu and are easily performed if the modem is attached to DTE or an external
BERT.
7.8.1 A
NALOG
L
OOPBACK
(ALB) T
EST
Analog loopback testing allows the user to test the local modem and its associated terminal independently from the telephone interface and the remote modem. Fig. 7-1 shows the connections automatically made during the test.
144
TRANSMITTER
RECEIVER
LOCAL MODEM
DATA TERMINAL EQUIPMENT
(DTE) AT LOCAL SITE
Fig. 7-1. Analog Loopback Test.
CHAPTER 7: Diagnostics
In Hayes emulation mode only, the ALB test can be initiated using the command &T1 (preceded by
AT). In any mode, the ALB test can be initiated by using the modem’s front panel controls, as explained in the following paragraphs.
Make sure the modem is idle, that the data rate is the same as that of the DTE and that the DTR circuit is on. (If TR is present on the EIA status screen, the DTR circuit is on.)
From screen 2 of the LCD MAIN
MENU, select TEST. This will take you to screen 1 of the LOCAL
TEST menu, where ALB will be displayed as one of the test selections. Select ALB.
The ANALOG LOOPBACK screen will be displayed, with ON and OFF as the possible selections.
Select ON to activate the test. (In general, the DSR during ALB test option discussed in chapter should be left ON—the default selection— to avoid disrupting the DTE and
DTE software operations.)
The EIA status screen will be displayed while the test is being conducted. Ensure that test data is being generated. Watch for data errors. By transmitting test data and comparing it with the received copy, the DTE and modem are checked for proper operation.
To end the test, press the ENT pushbutton to return to the
ANALOG LOOPBACK screen, and then select OFF.
7.8.2 A
NALOG
L
OOPBACK
S
ELF
-T
EST
(ALBST)
In the analog loopback self-test, the modem is placed in analog loopback and data is sent and received by an internal 511-bit pattern generator and receiver; therefore, no DTE or external
BERT is necessary. Fig. 7-2 shows the data flow for this test.
145
MODEM 32144
TRANSMITTER
PATTERN
GENERATOR
RECEIVER
PATTERN
DETECTOR
Fig. 7-2. Analog Loopback Self Test (ALBST).
In Hayes mode only, the
ALBST can be initiated using the command &T8 (preceded by AT).
In any mode, the ALBST can be initiated by using the modem’s front-panel controls, as follows:
From screen 2 of the LCD MAIN
MENU, select TEST. This will take you to screen 1 of the LOCAL
TEST menu, where ALBST will be visible as one of the selections.
Select ALBST.
The SELFTEST screen will be displayed, with ON and OFF as the possible selections. Select ON to activate the test. The EIA status screen will be displayed while the test is being conducted. If “ER” is present on the front panel, data errors have occurred. The ER indicator may flash on when the test is first turned on, but it should quickly go out and remain off until the end of the test.
146
CHAPTER 7: Diagnostics
To end the test, press the ENT pushbutton to return to the
SELFTEST screen, and then select OFF.
7.8.3 A
NALOG
L
OOPBACK
S
ELF
-T
EST
WITH
E
RRORS
(ST/E)
In the analog loopback self test with errors, data is sent and received by an internal 511-bit pattern generator and receiver; therefore, no DTE or external
BERT is necessary. This test differs from the ALBST in that errors are injected into the data flow every few seconds. The data flow is the same as that shown in figure -2
(the ALBST).
To run this test, follow these steps:
From screen 2 of the LCD MAIN
MENU, select TEST. This will take you to screen 1 of the LOCAL
TEST menu, where ST/E will be visible as one of the selections.
Select ST/E.
The SELFTEST W/ERROR screen will be displayed, with ON and OFF as the possible selections.
Select ON to activate the test. The
EIA status screen will be displayed.
The ER indicator should flash every few seconds, indicating that the pattern generator and detector are working. Errors are injected every few seconds. To end the test, press the ENT pushbutton to return to the SELFTEST W/ERROR screen, and then select OFF.
7.8.4 E
XTERNAL
A
NALOG
L
OOPBACK
(ALBX) T
EST
The external analog loopback test is available for 4-wire leased line mode only.
The ALBX test allows the user to test the local modem and its associated terminal and to verify the availability of the leased line circuit. The test circuit does not include the remote modem.
Fig. 7-3
shows the connections automatically made during the
ALBX test.
NOTE
The ALBX test may result in errors or may fail altogether even where conditions are satisfactory for normal operation. This is because the test channel presented to the modem during the
ALBX test.includes all impairments of both the inbound and outbound channels (amplitude distortion, delay distortion, noise, etc.). The main purpose of the ALBX test is to verify that the modem is connected to the leased line and that the leased line circuit is complete. The test is not meant to assess the suitability of the leased line.
147
MODEM 32144
The ALBX test can be initiated by using the modem’s front panel controls, as explained in the following paragraphs.
Make sure the local modem is not in communication with the remote modem, that the data rate is the same as that of the DTE and that the DTR circuit is on. (If TR is present on the EIA status screen, the DTR circuit is on.)
From screen 2 of the LCD MAIN
MENU, select TEST. Go to screen 2 of the LOCAL TEST menu and select ALBX.
EXTERNAL LOOPBACK
(LEASED LINE)
RECEIVER
TRANSMITTER
LOCAL MODEM
DATA TERMINAL EQUIPMENT
(DTE) AT LOCAL SITE
Fig. 7-3. External Analog Loopback (ALBX) Test.
148
CHAPTER 7: Diagnostics
The ANALOG LOOP(EXT) screen will be displayed, with ON and OFF as the possible selections.
Select ON to activate the test. (In general, the DSR during ALB test option discussed in chapter should be left ON—the default selection— to avoid disrupting the DTE and
DTE software operations.)
The EIA status screen will be displayed while the test is being conducted. If no external loopback is present, the status screen will display an “IDLE” message. If a loopback is present, handshakesequence codes will appear (H-01, etc.), followed by the modem speed. Make sure that test data is being generated. Watch for data errors. By transmitting test data and comparing it with the received copy, the DTE and modem are checked for proper operation.
During the ALBX test, RD (receive data) may appear on the status screen even though no data is being received—this is normal.
On a flat line, the MODEM modem in ALBX test mode will train and remain running across the following range of signal loss: in V.32 mode, 0–51 dBm (0–52 dBm at 12.0 Kbps); for V.33
operation, 0-47 dBm; and for Bell
208A/B operation, 0–37 dBm. If signal loss exceeds these limits, the test may not start or may be halted.
During the ALBX test, the modem will attempt to retrain upon loss of carrier. In switched carrier mode, the modem will attempt to retrain upon loss of
RTS.
To end the test, press the ENT pushbutton to return to the
ANALOG LOOP(EXT) screen, and then select OFF.
7.8.5 E
XTERNAL
A
NALOG
L
OOPBACK
S
ELF
-T
EST
(ALXST)
The external analog loopback self test is available for 4-wire leased line mode only.
The ALXST places the modem in analog loopback and causes data to be sent and received by an internal
511-bit pattern generator and receiver; therefore, no DTE or external BERT is necessary. As shown in Fig. 7-4, the test circuit includes the leased lines (the external loopback).
149
MODEM 32144
NOTE
The ALXST may result in errors or may fail altogether even where conditions are satisfactory for normal operation. This is because the test channel presented to the modem during the
ALXST includes all impairments of both the inbound and out-bound channels (amplitude distortion, delay distortion, noise, etc.). The main purpose of the ALXST is to verify that the modem is connected to the leased line and that the leased line circuit is complete. The test is not meant to assess the suitability of the leased line.
TRANSMITTER
PATTERN
GENERATOR
RECEIVER
PATTERN
DETECTOR
EXTERNAL LOOPBACK
(LEASED LINE)
Fig. 7-4. External Analog Loopback Self Test (ALXST).
150
CHAPTER 7: Diagnostics
The ALXST can be initiated from the modem’s front panel, as follows:
From screen 2 of the LCD MAIN
MENU, select TEST. Go to screen 2 of the LOCAL TEST menu and select ALXST.
The ANALOG ST (EXT) screen will be displayed, with ON and OFF as the possible selections. Select
ON to activate the test.
The EIA status screen will be displayed while the test is being conducted. If no external loopback is present, the status screen will display an “IDLE” message. If a loopback is present, handshake sequence codes will appear, followed by the modem speed. If
“ER” is present on the front panel, data errors have occurred. The ER indicator may flash on when the test is first turned on, but it should quickly go out and remain off until the end of the test.
The information at the end of the previous section (for the ALBX test) concerning signal loss, loss of carrier and loss of RTS also apply to the ALXST.
To end the test, press the ENT pushbutton to return to the
ANALOG ST (EXT) screen, and then select OFF.
7.8.6 D
IGITAL
L
OOPBACK
T
EST
(DLB)
Digital loopback testing determines the operational performance of the local modem, the remote modem, and the telephone line as a composite system. For this test, data must be sent and received at the remote modem. This test regenerates the data and loops it back to the remote modem. As with the ALB test, a comparison of the results of the DLB test can indicate whether or not the DTE is performing satisfactorily. A comparison of the results of the
ALB and DLB tests can help determine whether the modem or the telephone line is defective.
In the DLB test, the data to be sent and received is originated and checked by the DTE or external
BERT. Fig. 7-5 shows the data flow for this test.
151
MODEM 32144
RECEIVER
TRANSMITTER
REMOTE
MODEM
TRANSMITTER
RECEIVER
LOCAL MODEM
DATA TERMINAL EQUIPMENT
(DTE) AT LOCAL SITE
Fig. 7-5. Digital Loopback (DLB) Test.
In Hayes mode only, the DLB test can be initiated using the command &T3 (preceded by AT).
In any mode, the DLB test can be initiated using the modem’s frontpanel controls, as follows:
From screen 2 of the LCD MAIN
MENU, select TEST. Go to screen 2 of the LOCAL TEST menu and select DLB.
The DIGITAL LOOPBACK screen will be displayed, with ON and OFF as the possible selections.
Select ON to activate the test. The
EIA status screen will be displayed while the test is being conducted.
Make sure that test data is being generated. Watch for data errors.
By transmitting test data and comparing it with the received copy, the DTE is checked for proper operation. To end the test, press the ENT pushbutton to return to the DIGITAL
LOOPBACK screen, and then select OFF.
152
CHAPTER 7: Diagnostics
7.9 Remote Modem Diagnostics
The modem is capable of performing two tests on compatible remote modems: remote digital loopback (RDL) and remote digital loopback self-test (RDLST). If a problem is encountered and the local modem passes all diagnostic tests, the local modem can test the remote modem.
There are two (noncontiguous)
REMOTE TEST screens on the modem LCD: (1) The remote tests are initiated from the REMOTE
TEST menu. (Select RMT from
MAIN MENU screen 2, and then select TEST. Then select the test type.) (2) A remote test cannot be initiated unless the Remote Test option is enabled on the remote modem. This option (also
REMOTE TEST on the LCD) is accessed via SETUP screen 4.
7.9.1 R
EMOTE
D
IGITAL
L
OOPBACK
(RDL) T
EST
The RDL test (Fig. 7-6) allows testing of the local modem, remote modem and telephone line from the local site.
In Hayes mode only, the RDL test can be initiated using the command &T6 (preceded by AT).
In any mode, the RDL test can be initiated from the modem’s front panel, as follows:
Both modems should be on-line and should be tested at the data rate used by the DTE. Ensure that the DTR circuit is on. (If TR is present on the EIA status screen, the DTR circuit is on.)
From screen 2 of the MAIN
MENU, select RMT, and then select
TEST. From the REMOTE TEST menu, select RDL.
153
MODEM 32144
RECEIVER
TRANSMITTER
LOCAL
MODEM
DATA TERMINAL EQUIPMENT
(DTE) AT LOCAL SITE
TRANSMITTER
RECEIVER
REMOTE MODEM
Fig. 7-6. Remote Digital Loopback (RDL) Test.
From the REMOTE DIGIT
LOOP screen, select ON to activate the test. The status screen will be displayed as the test is being conducted. Make sure that test data is being generated. Watch for data errors. By transmitting test data and comparing it with the received copy, the modems as well as the telephone line can be checked for proper operation.
To end the test, press the ENT pushbutton to return to the
REMOTE DIGIT LOOP screen, and then select OFF.
7.9.2 R
EMOTE
D
IGITAL
L
OOPBACK
S
ELF
-T
EST
(RDLST)
The RDLST allows testing of the local modem, remote modem and telephone line from the local site as did the previous test, except that the test data is generated by internal modem circuitry as opposed to a DTE or external
BERT. Fig. 7-7 shows the connections automatically made during the test.
154
CHAPTER 7: Diagnostics
In Hayes mode only, the
RDLST can be initiated using the command &T7 (AT &T7). In any mode, the RDLST test can be initiated from the front panel as follows:
Both modems must be on-line.
From screen 2 of the MAIN MENU, select RMT, and then select TEST.
From the REMOTE TEST menu, select RDLST.
From the RDL SELFTEST screen, select ON to activate the test. The status screen will be displayed as the test is being conducted. If “ER” is present on the status screen, the modem is detecting errors. If numerous errors are detected, steps should be taken to try to identify their source.
TRANSMITTER
RECEIVER
PATTERN
GENERATOR
PATTERN
DETECTOR
TRANSMITTER
RECEIVER
REMOTE MODEM
LOCAL MODEM
Fig. 7-7. Remote Digital Loopback Self Test.
155
MODEM 32144
Appendix A: Quick Setup
Configurations
Table A-1
shows the modem configuration—i.e., the default setting for each option—for each of the Quick Setup modes. When you select a Quick Setup, the modem automatically sets all options as indicated in the table.
The options are listed in the same order in which they appear on the
LCD flow chart.
Some options can be selected via
Summary Setup only. These options are not listed in Table A-1.
The factory-default settings for these options are shown in
Appendix B
.
Instructions for selecting Quick
Setups are included in Chapter 2.
156
APPENDIX A: Quick Setup Configurations
Table A-1. Quick Setup Configurations
157
MODEM 32144
Table A-1. Quick Setup Configurations (continued)
158
APPENDIX A: Quick Setup Configurations
Table A-1. Quick Setup Configurations (continued)
159
MODEM 32144
Table A-1. Quick Setup Configurations (continued)
160
APPENDIX A: Quick Setup Configurations
Table A-2. Additional Quick Setup Configurations
Default settings listed by Quick Setup mode
Option
STD
Bell 4-wire
208
Communication Standard option
208
1 leased
V.29
V.29
V.29
fast master
V.29
V.29
fast slave
V.29
Speed Limit option, V.32, V.32M, V.32/14.4, V.32/14.4M, V.32/19.2, V.32/19.2M
MAX DCE
RATE
4800 9600 9600 9600
MIN DCE 4800 4800 4800 4800
Option
Default settings listed by Quick Setup mode
Bell 208 1
Disable
4-wire leased V.29
Disable
V.29 fast master
Disable BUFFER
DTE SPEED 38.4 Kbps 38.4 Kbps
V.29 fast slave
Disable
38.4 Kbps 38.4 Kbps
RTS RTS RTS FLOW
CONTROL
DTE-DCE
FLOW
CONTROL
DCE-DTE
RTS
CTS
DTE
PASS-THRU
FLOW CTRL
Disable
CTS
Disable
CTS
Disable
CTS
Disable
161
MODEM 32144
Table A-2 (continued). Additional Quick Setup Configurations
ADDRESS
2
DIALER
MODE
AUTO
ANSWER
(Miscellaneous)
999,999 999,999
OFF
Enable
OFF
Enable
999,999
OFF
Disable
999,999
OFF
Disable
Data Format Options
DATA TYPE Sync Sync
10 10 CHAR
LENGTH
PARITY None None
Sync
10
Sync
10
None None
Disconnect Options
Disable Disable RX SPACE
DISC’T
TX SPACE
DISC’T
Disable Disable
Disable
Disable
Disable
Disable
CARRIER
DISC’T
Enable
LINE CURR Enable
DISC’T
RTS DISC’T OFF
Enable
Enable
Enable
Enable
Enable
Enable
OFF OFF OFF
2 Quick Setup does not change the address to the default address, but a factory reset does.
162
APPENDIX A: Quick Setup Configurations
Table A-2 (continued). Additional Quick Setup Configurations
Test Options
DSR
DURING
ALB
ON ON ON ON
Enable Enable Enable REMOTE
TEST
Enable
EIA Options
CTS to EIA Normal
Normal CD to EIA
DSR to EIA Normal
DTR from EIA Normal
ALBT DTE
CTRL’ED
RDL DTE
CTRL’ED
TM to EIA
Disable
Disable
True
Modem Setup Options
CD LEVEL,
LEASED
-26 dBm
CD LEVEL,
DIAL
TX LEVEL,
LEASED
-43 dBm
0 dBm
TX LEVEL,
DIAL
Permis.
SIGNAL
QUAL LEVEL
10 4
Normal
Normal
True
True
Disable
Disable
True
-26 dBm
-43 dBm
0 dBm
Permis.
10 4
Normal
Normal
True
True
Disable
Disable
True
-26 dBm
-43 dBm
0 dBm
Permis.
10 $
Normal
Normal
True
True
Disable
Disable
True
-26 dBm
-43 dBm
0 dBm
Permis.
10 4
163
MODEM 32144
Table A-2 (continued). Additional Quick Setup Configurations
T-III T-III COMPR
EQUAL
TRELLIS
CODE
TRANSMIT
CLOCKING
T-III
Enable
Internal
T-III
Enable
Internal
T1 TIMER 0.8 sec 0.8 sec
Default settings listed by Quick Setup mode
AUTO-
RETRAIN
Enable Enable
ORIG ANS/ORG
DEFAULT
ANS TONE
ORIG
2100 Hz
Enable FRONT
PANEL
SPKR CTRL Til-CD
SPKR VOL Medium
GUARD
TONES
V.8 PROC
OFF
TRAINING
LENGTH
Enable
V.13
OPERATION
OFF
Long
CARRIER
CTS
Switched
RTS
RTS-CTS DLY 150 ms
164
2100 Hz
Enable
Til-CD
Medium
OFF
Enable
OFF
Long
Constant
RTS
0
Enable
Internal
0.8 sec
Disable
ORIG
2100 Hz
Enable
Til-CD
Medium
OFF
Enable
OFF
Short
Constant
RTS
0
Enable
Internal
0.8 sec
Disable
ANS
2100 Hz
Enable
Til-CD
Medium
OFF
Enable
OFF
Short
Switched
RTS
0
APPENDIX A: Quick Setup Configurations
Table A-2 (continued). Additional Quick Setup Configurations
Auto-Recovery Options
AUTO-RECV None
SELECT
AUTO-RECV OFF
RETURN
AUTO-RECV 20 min
TEST INT’VL
AUTO-RECV INTER
TEST TYPE
LCD Intensity Option
LCD
INTENSITY
5
None
OFF
20 min
INTER
5
None
OFF
20 min
INTER
5
None
OFF
20 min
INTER
5
165
MODEM 32144
Appendix B: Summary Setup
Summary Setup is an advanced feature designed to allow experienced users to quickly change option settings for any mode. Most options can be viewed from and changed using a single LCD screen.
Summary Setup is the fastest way to selectively change multiple options; however, because the Summary
Setup screens show numerical codes with very little explanation, this method of options selection is recommended only for experienced users.
Even though Summary Setup offers these advantages, it is recommended only for experienced users because there is very little guidance on the LCD screen to indicate which option is being changed.
Changes made through Summary
Setup modify the active modem configuration and are saved to memory when you exit Summary
Setup.
B.1 Summary Setup LCD Screens
Summary Setup (SUMMARY) is accessed from screen 6 of the
SETUP menu. From the
SUMMARY screen, choose SETUPS to change options—but for Hayes mode operation (only), choose AT to change options for which there are associated AT commands
(Table B-1).
If you select AT, the AT
PROFILES screen will be displayed.
When you select a Hayes mode configuration profile (user profile) from the AT PROFILES screen, the
MODEM displays a setup screen for the selected profile. The selected profile is used as the active configuration and is also designated as the default user profile. Select 0 (pushbutton 1) to select profile 0; select 1
(pushbutton 2) to select profile 1.
Pushbutton 3, with the AT
PROFILES screen displayed, enables you to select the default configuration profile: By pressing pushbutton 3, you can toggle
(switch) between profile 0 or profile 1 as the default—the effect is the same as issuing the &Y command (&Y0 or &Y1).
The SUMMARY screen includes a four-digit checksum value to the right of the word “SUMMARY.”
This number will change if any of the option settings are changed, so it allows you to determine if any of the modem’s option settings have been changed, although you cannot determine from this number which options have been changed. After setting up the MODEM, record this number for possible later reference.
166
B.2 Changing Options via Summary
Setup
The appearance of the three setup screens selected via SETUPS and
AT (profile 0 or 1) is essentially the same: Brief descriptive information on the top line and a long string of numbers on the bottom line. The numbers are broken down into groups, with each group representing a category of options (dial line options, EIA interface options, etc.).
Each digit position represents an option, and the number in each digit position indicates the current option setting (parameter). To change an option setting, use the front panel pushbuttons to change the parameter (number), as explained in the following section.
The diagrams on the following pages show—
• Which options are included in each option group
• Which option is indicated by each digit position within the group
• The possible parameters for each option
APPENDIX B: Summary Setup
B.2.1 S
UMMARY
S
ETUP
P
USHBUTTON
F
UNCTIONS
The three Summary Setup screens are different from all other modem screens in that you can scroll across the string of numbers; also, the pushbutton functions are different.
For the three Summary Setup screens only, the modem pushbuttons function as follows:
• Pushbutton 1 moves the cursor to the left. Pushbutton 3 moves the cursor to the right. If the cursor is at the end of the screen, the screen will scroll one character at a time.
• Pushbutton 2 increments the blinking value (i.e., the parameter, or current option setting). The value will cycle through the highest possible parameter value and then back to 0 or 1.
• The right arrow button moves the screen to the beginning of the next group of options to the right. The left arrow button moves the screen to the beginning of the next group of options to the left. Groups of options are separated by blank spaces on the LCD.
167
MODEM 32144
NOTE
On the Summary Setup screens that show AT profiles 0 and 1, the cursor location is indicated by a solid black box when the cursor is positioned in a blank cell (one with no characters).
B.2.2 E
XPLANATION OF
S
UMMARY
S
ETUP
S
CREENS
Note that options are identified on the Summary Setup screens only by the relative positions of the numbers within the number string, as indicated in the following diagrams. Each digit position represents an option, and the number in each digit position indicates the current option setting
(parameter).
The string of numbers in each diagram shows the factory default setting for each option (i.e., the
Hayes mode default settings). Each diagram also identifies all possible settings for each option.
NOTE
Numbers that are not identified in the following diagrams represent option settings that are reserved for future use or factory use.
These settings should not be changed.
APPENDIX B: Summary Setup
PRI
0 1 2 1 2 0 8 5 2
LCD
Speed type: 0=Auto (V.32/208), 1=V.33, 2=V.32/32bis, 3=Bell 208
Speed limit, min. (bps): 0=9600, 1=4800, 2=2400,3=1200
4=600, 5=0-300,6=1200/75,7=14,400, 8=12,000, 9=7200
Speed limit, max. (bps): 0=9600,1=4800,2=2400,3=12000,4=600,
5=0-300, 6=EIA-23, 7=1200/75, 8=14,400,9=12,000,A=7200
Buffer mode/speed conversion: 0=enable, 1=disable
V.42 mode : 0=off, 1=mandatory, 2=automatic
Dialer mode: 0=off, 1=Hayes, 2=DTR dialing;
3=V.25bis, async; 4=V.25bis, sync, character-oriented;
5=V.25bis, sync, bit-oriented; 6=Penril mode
Character length (bits): 0=8, 1=9, 2=10, 3=11
Data format: 0=sync, 1=async
Line type: 0=2--wire dial, 1=2-wire leased, 2=4-wire leased
NOTES: Speed limit, min., and speed limit, max.: 7200 bps parameters are available only if V.32bis mode is enabled.
ALX V.32 and ALX V.32M only: Available speed limit selections: Max., 0-7 and A; min., 0=6 and 9. Default max. speed limit setting: 0 (9600 bps).
Speed type: Settings 0, 1 and 3 are not available on all all ALX models.
Fig. B-1. Primary Options.
169
MODEM 32144 a d d r
9 9 9 9 9 9
Group address
Unit address
Fig. B-2. Address.
dial
0 0 0 0 0 0 1 0 2 1 0
Pulse dialing rate (pulse per sec): 0=10, 1=20
Wait for carrier (sec): 0=30, 1=45, 2=60, 3=75
T1 timer (sec): 0=0, 1=0.3, 2=0.8, 3=1.6, 4=3.
Carrier detect level, dial (dBm): 0= -51, 1= -41, 2= -34
TX level, dial: 0=programmable, 1=permissive
Disconnect, RTS (sec): 0=off, 1=20, 2=40 . . .7=140
Disconnect, line current: 0=enable, 1=disable
Disconnect, carrier: 0=enable, 1=disable
Disconnect, TX space: 0=enable, 1=disable
Disconnect, RX space: 0=enable, 1=disable
Auto-answer: 0=enable, 1=disable
Fig. B-3. Dial Line Options.
170
APPENDIX B: Summary Setup eia
0 1 0 1 1 1 0 0 0
CD and DSR delay: 0=disable, 1=enable
Test mode: 0=normal, 1=true
Remote digital loopback test: 0=enable, 1=disable
Analog loopback test: 0=enable, 1=disable
CTS: 0=normal, 1=follow RTS, 2=true, 3=on
Carrier detect: 0=normal, 1=true, 2=toggle
DSR: 0=normal, 1=true, 2=crossover
DTR: 0=normal, 1=true
Fig. B-4. EIA Interface Options.
V.42 <1>
0 0 3 3 5 3 1 1
V.42 <1>
2 0 0 0 0 1 0 2 1
"V.42 <1>" and "V.42 <2>" are displayed to help indicate the relative position of individual options across the LCD.
Link flow control: 0=disable, 1-enable, 2=slaved
DCE pass-through flow control: 0=disable, 1=enable
Selective retransmission: 0=disable, 1=enable
V.42bis: 0=enable, 1=disable
V.42 protocol: 0=LAPM only, 1=MNP only, 2=LAPM/MNP
DTE pass-through flow control: 0=enable, 1=disable
Flyback buffer: 0=enable, 1=disable
Break handling: 0=none, 1=destr./expedited, 2=non-destr./expedited,
3=non-destr./non-expedited
MNP class (limit): 1=class 1, 2=class 2, 3=class 3, 4=class 4, 5=class 5
Flow control, DCE to DTE: 0=none, 1=CTS, 2=DC1/DC2, 3=DC1/DC3
Flow control, DTE to DCE: 0=none, 1=RTS, 2=DC1/DC2, 3=DC1/DC3
Parity: 0=none, 1=odd.2=even, 3=mark, 4=space
DTE speed (bps): 0=38,400, 1=19,000, 2=9600, 3=4800, 4=2400,
5=1200, 6=600, 7=300, 8=110
Fig. B-5. V.42 Error Correction Options.
171
MODEM 32144
L. L.
1 0 0 2 0 0 1 0
Auto-recovery test interval (min): 0=10, 2=40, 3=60
Auto-recovery return (sec): 0=off, 1=10, 2=40, 3=60, 4=120
Auto-recovery select: 0=none, 1=dial if bad 1 min ... 4=dial if bad 4 min,
5=dial if bad 30 sec 96-8 not used), 9=manual recovery
Carrier detect level, leased (dBm): 0= -43, 1= -33, 2=-26
TX level, leased (dBm): 0=0, 1= -1... 9= -9, A= -10 ... F= -15
TX clocking: 0=internal, 1=received clocking, 2=external
Answer/originate: 0=answer, 1=originate
Fig. B-6. Leased Line Options.
172
APPENDIX B: Summary Setup
"pump1," "pump2," and "pump3" are displayed to help indicate the relative positions of individual options across the LCD.
pump 1
2 0 0 2 1 0 3 0 0 0 1
The "pump2", and "pump3" options are identified below.
Phase reversal in answer tone: 0=enable, 1=disable
Auxiliary channel: 0=enable, 1=disable
Speed fallback: 0=enable, 1=disable
Trellis coding: 0=enable, 1=disable
Answer tone: 0=2225 Hz, 1=2100 Hz
Guard tone: 0=550 Hz, 1=1800 Hz, 2=off
Auto-retrain: 0=enable, 1=disable
Signal quality level (error/bits): 0=1 in 10^3, 1=1 in 10^5
Compromise equalizer type: 0=I, 1=II< 2=III, 3=IV, 4=off
Fig. B-7. Data Pump 1 Options.
pump 2
0 0 0 0 0 1 1 0 0 0 pump 3
0 0 0 0 0 1 0 0
1
2
3
4
5
6
7
8
V.26 scrambler: 0=disable, 1=enable
Anti-streaming timer: 0=disable, 1=enable
V.26 dibit encoding: 0=alternative A, 1=alt. B
Echo protection tone: 0=disable, 1=short, 2=long
V.27bis 2400-bps alternatives: 0=alternative i, 1=alt. ii
V.3x/208 auto-detect mode: 0=disable, 1=enable
V.22bis S1 duration (ms): 0=100, 1=150
Fast connect 103 mode: 0=disable, 1=enable
8
9
10
Forward rate renegotiation: 0=disable, 1=enable
Retrain threshold (error/bits): 0=10^4, 1=10^6
208 phase detection: 0=normal, 1=compensated
1
2
3
4
5
6
Rate renegotiation (RRP): 0=disable, 1=enable
Turnaround delay: 0=disable, 1=enable
Satellite delay: 0=disable, 1=enable
RTS-to-CTS delay (ms): 0=none, 1=15, 2=50, 3=150
CTS: 0=always ON, 1=follow RTS
Carrier type: 0=switched, 1=constant
Fig. B-8. Data Pump 2 and 3 Options.
173
MODEM 32144 misc 1
1 2 3 0 0 0 0
"misc1," "misc2," and "misc3" are displayed to help indicate the relative positions of individual options across the LCD.
The "misc2", and "misc3" options are identified below.
Op. mode fallback: 0=Bell 212A and 103, 1=V.22/V.21/V.23
Remote test: 0=enable, 1=disable
DSR during ALB: 0=enable, 1=disable
FP: 0=enable, 1=disable
LCD intensity: 0, 1... 7 (7=greatest intensity)
Speaker volume: 0=low, 1=medium, 2=high
Speaker control: 0=on, 1=on till CD, 2=off misc 2 misc 3
0 1 0 0 0 0 0 F F F F 1 0 0 0 0 0 0 0 0
Low-profile DIAG LED:
0=Connect status, 1=DTR status
CFI AB response on disconnect:
0=disable, 1=enable
Wait for MNP link request (sec): 0=3, 1=7
Leased line interrupt:0=off, 1=on
Remote RTS signaling: 0=off, 1=on
Multimode handshake: 0=T1 timer,
1=V.32bis Annex A
Answer tone detection: 0=enable, 1=disable
Answer tone detection: 0=enable, 1=disable
V.13 operation: 0=off, 1=TX only, 2=RX only, 3=TX and RX
DTE=DCE speed: 0=disable, 1=enable
Penn/V.25bis DTR dialing: 0=enable, 1=disable
Fig. B-9. Miscellaneous Options.
174
APPENDIX B: Summary Setup
AT commands
AT/ commands
(most are for
V.42 options)
AT & commands
S registers
AT b e f l m q v x y
11 0 2 1 0 1 4 1
AT & c d g j l p q r s x
1 2 0 0 0 0 0 0 0 0 s00 s18 s25 s26
001 000 005
AT / a b c d f k m n p q t v x
315013032330011
Flow control, DCE
Flow control, DTE
Load inactivity timer
Fig. B-10. Hayes Mode Options—For Each AT Profile.
175
MODEM 32144
Appendix C: Connectors, Adapters, and Jumpers
This appendix provides a detailed description of al modem connectors, including pin assignments. It also includes a description of the modem jumper functions and a diagram that shows you where to find the jumpers.
C.1 Connectors and Adapters
The modem includes the following connectors (labeled on the rear panel as indicated below):
• DTE—25-pin (DB25) RS-232/D female cable connector, for connection to DTE (computer or terminal)
• DIAG—RJ-45 modular jack
(diagnostic connector), for diagnostic port control
(optional)
• POWER—Five-pin DIN connector for AC power
• TX DIAL—RJ-45 modular jack for connection to a dial line
• RX DIAL—(Ignore “RX DIAL” label.) RJ-45 modular jack for alternate leased line connection (when an 8-pin connector is required)
• LEASED LINE—RJ-11 modular jack, for (6-pin) leased line connection
• PHONE—RJ-11 modular jack, for connection to a telephone handset (optional)
These connectors are illustrated in Chapter 2, which explains how to install the modem and how to make the connections referred to above.
The modem includes an edge connector for optional rack mounting. When the modem is rack mounted, the edge connector performs the functions of all the connectors listed above (and the other connectors are not used).
C.1.1 C
ONNECTOR
P
IN
A
SSIGNMENTS
For users who need to know connector pin assignments, this information is provided in Figure
C-1
(DIAG, TX DIAL, RX DIAL,
LEASED LINE, and PHONE connectors) and in Table C-1
(DTE interface connector).
176
APPENDIX C: Connectors, Adapters, and Jumpers
Dial Line Connector
1 2 3 4 5 6 7 8
RJ-45
Pin
3
4
5
6
7
8
Function
A/MI
Ring
Tip
A1/MIC
PC
PR
Phone Connector
1 2 3 4 5 6
RJ-11
Pin
2
3
4
5
Function
A
Ring
Tip
A1
DTE
REAR PANEL
DIAG
POWER
TX
DIAL
RX
DIAL
LEASED
LINE
PHONE
DB25
Diagnostic Connector
Leased Line
Connector
1 2 3 4 5 6
RJ-11
Pin
2
3
4
5
Function
RXLL
TXLL
TXLL
RXLL
1 2 3 4 5 6 7 8
RJ-45
Pin Function
1
2
4
Constellation Y Output
Constellation X Output
Ground (for transmit and
5
6
receive data and constellation)
Receive Data (output from
modem)
Transmit Data (input to modem)
DIAG port always appears to a system as a DCE port.
Alternate Leased
Line Connector
(Ignore “RX DIAL” Label)
1 2 3 4 5 6 7 8
RJ-45
Pin
1
2
7
8
Function
TXLL
TXLL
RXLL
RXLL
Figure C-1. Connector Pin Assignments.
All connectors are shown as viewed from the back of the modem.
Pins not included in the listings above are not used.
177
MODEM 32144
Table C-1. Pin Assignments—DB25 TIA/EIA Interface Connector
5
6
Pin
3
4
1
2
Function Designation
EIA ITU-T LCD
AA 101 Frame ground—not connected
Transmit (send) data (TD) BA
BB Received data (RD)
Request to send (RTS) CA
CB Clear to Send (CTS)
Data Set (modem) Ready (DSR) CC
103
104
105
106
107
TD
RD
RS
CS
MR
Source
DTE
Modem
DTE
Modem
7
8
9
10
Signal ground (SG)
Carrier detect (CD)
Testing voltage, +10V
Testing voltage, -10V
Transmit clock (TC)
Receive clock (RC)
Analog loopback (ALB) control 1
Data terminal ready (DTR)
AB
CF
+P
-P
102
109 CD
Modem
Ground
Modem
Modem
15
17
18
20
21
DB
DD
CN
CD
CN
114
115
108/2 TR
Modem
Modem
Modem
DTE
DTE
DTE
22
24
Remote digital loopback (RDL) control 1
Ring indicator (RI)
External transmit clock (XTC)
CE
DA
125
113
R Modem
DTE
25 Test mode indicator (TM) 2 CN TM Modem
1 + voltage activates indicated loopback test (but only if ALB-DTE Ctrl’ed or RDL-
DTE Ctrl’ed option is enabled);—voltage disables test.
2 Alternately, pin 25 may be used for analog loopback (ALB) control.
178
APPENDIX C: Connectors, Adapters, and Jumpers
C.2 Jumpers
WARNING
Jumpers should be switched only by qualified service personnel.
For most applications, there is no need to reset the modem’s internal jumper switches. However, a jumper switch will have to be reset if you need to—
Connect frame ground to signal ground, Switch from A/A1 control to MI/MIC control, Strap the modem for use in a DC rack enclosure, or Change the function of EIA interface pin 25.
If you need to reset a jumper switch, refer to the following page to determine the jumper that should be switched, where it is located, and how it should be set.
The jumpers are numbered on the circuit board; for example, JP4 is jumper 4. To access the jumpers, unscrew the four screws on the bottom of the modem and carefully lift off the cover.
WARNING
Improper setting of AC and
DC power jumpers could result in serious damage to the modem.
179
MODEM 32144
Jumper(s)
JP1
Table C-2. Jumper Switch Functions
Position1
FG
Alternate position
(no legend)
Function
Frame and signal ground connected
Not connected
JP2, JP3
(Set to same position)
JP4, JP5,
JP8
(Set to same position)
A1
MI
AC
Alternate position
A/A1 control
MI/MIC control
AC power
DC power (for Telco 48 VDC battery)
JP7 TM (output)
AL (input)
Pin 25 used as test mode indicator
Pin 25 used for analog loopback
1As indicated by legend printed on modem circuit board.
Factory settings are shown in boldface.
180
APPENDIX D: DC Voltage Models
Appendix D: DC Voltage Models
D.1 Introduction
The modems with codes MD833A-D12, MD833A-D24, and MD833A-D48 are pre-configured for DC voltage operation. The MD833A-D12 is preconfigured for use with a -12 VDC power source, the MD833A-D24 is preconfigured for use with a -24 VDC power source, and the MD833A-D48 is pre-configured for use with a -48 VDC power source.
This addendum provides installation and jumper information for the
DC pre-configured modems for applications where an external DC power source will be used (i.e., not DC power provided from a rack enclosure).
If the modem is to be installed in a rack, refer to the instruction manuals for the modem and the rack.
CAUTION
The -48 VDC model should be used only with an external DC power source.
For modems using an external DC power source, the information in this addendum about installation and jumper settings supersedes the information in the rest of the Modem 32144 manual. However, all other information in the instruction manual is applicable.
181
MODEM 32144
D.2 Installation
Use the supplied cable to attach the modem to the external DC power source, as shown in Fig. D-1.
DIAG
POWER
TX
DIAL
LEASED
LINE PHONE
Black
Red
Pos. (+) source
Neg. (-) source
Fig. D-1. Attaching the supplied cable to the DC power source.
Refer also to Section 2.1,
Installation
but ignore information about the AC power transformer cable.
182
APPENDIX D: DC Voltage Models
D.3 Jumper Settings
The power jumpers have been preset at the factory for DC voltage operation as shown in Tables D-1.
Table D-1. Jumper Settings for -12/-24/-48 VDC Operation
Jumper(s)
JP2
JP3, JP4
(set to same position)
Setting
Pins 2 and 3 connected
Pins 1 and 2 connected
For other jumper settings, refer to the rest of this manual. (But for the DC modems, ignore the information in the manuals for jumpers JP2, JP3, and JP4.)
183
MODEM 32144
D.4 Jumper Locations
The jumper locations are shown below for your information; however, since the jumper settings are pre-configured, you should not have to change them.
JP6
JP1
JP3
JP5
JP4
JP2
JP8
JP7
Fig. D-2. Partial view of modem circuit board, showing jumper locations.
For each jumper, pin 1 is identified by a “1” on the modem circuit board. (The JP2 pin 1 label may be difficult to read; JP2 pin 1 is the pin closest to the edge connector.)
184
Appendix E: LCDFlow Chart
Power-on Screen
V.32bis/14.4M
V.32
V4.51/3.25
EIA status screen: Not all abbreviations will be present at same time. (R in upper left corner indicates an incoming ring.)
D TR MR RS CS TD
9600 TM ER CD RD
QUALITY 000
STATUS SCREENS
LINE LEVELS. dBm
TX=-09 RX=-24
ECHO: msec
020
Software revision levels (may be different than shown here.)
Bar graph
QUICK SETUP
2-W DIAL (HAYES)
<1> QUICK SETUP
V25 DIAL (Async)
<2> QUICK SETUP
V25 DIAL (Syn_c)
<3> QUICK SETUP
V25 DIAL (Syn_b)
<4>
Hz
1.0
CHANNEL FREQ
OFFSET: 1.0 Hz
THROUGHPUT
15000 BPS
PKT: SIZE
255
TX
0233
ER
00
MODE
V42bis
RATE
38400
Except for the power-on screen, the data shown on these screens will change, depending on external conditions and the modem's operational status.
QUICK SETUP MENU
The Quick Setup screens are used to quickly select pre-set modem configurations for various applications.
QUICK SETUP
2-W DIAL (DUMB)
<5> QUICK SETUP <6>
2-W LEASED (ORG)
QUICK SETUP <7>
2-W LEASED (ANS)
QUICK SETUP <8>
4-W LEASED (ORG)
QUICK SETUP <9>
4-W LEASED (ANS)
QUICK SETUP
4-WLL V.33
<10> QUICK SETUP
2-W DIAL (208)
<11> QUICK SETUP
2-W DIAL V32/208
<12> QUICK SETUP
4-WLL V.29
<13> QUICK SETUP <14>
V.29 FAST MASTER
QUICK SETUP
V.29 FAST SLAVE
<15>
MAIN MENU
TALK QUICK
<1>
DIAL
* *
MAIN MENU
SETUP TEST
<2>
RMT
* *
MAIN MENU
RESET RATE
<3>
(Resets modem)
RATE
DOWN UP
SETUP
TYPE
<1>
LINE SPEED
This screen is displayed only if V.32bis mode is selected.
SETUP <2>
V42 ADDR DIALER
SETUP <3>
ANSWER DATA DISC
Continued below
SPEED TYPE
DEC
V32
INC
LINE TYPE
2W-D 2W-LL 4W-LL
SPEED LIMIT
MAX MIN
MIN RATE:
DEC
0-300
INC
V42 CONTROL
V42 SEL
<1>
BUFFER
BUFFER SELECT
ENABLE DISABLE
Set automatically in Hayes mode only.
V42 CONTROL
DTE
<2>
FLOW
FLOW CONTROL
DTE-DCE
<1>
DCE-DTE
ADDRESS:
DEC
999,999
INC
DIALER
DEC
FLOW CONTROL
PASSTHRU
<2>
V42
MODE CLASS BREAK
V42 SELECTION
PROTOCOL V42bis
DTE SPEED:
DEC
38,400
INC
PASSTHRU MODE
ENABLE DISABLE
HAYES
INC
AUTO-ANSWER
ENABLE DISABLE
DISCONNECT
RX
<1>
TX
RX SPACE DISC'T
ENABLE DISABLE
TX SPACE DISC'T
ENABLE DISABLE
DISCONNECT <2>
CARR.
CURR.
RTS
RTS DISC'T
DEC
OFF
INC
CURRENT DISC'T
ENABLE DISABLE
MAX RATE:
DEC
19,200
INC
* See reverse side of chart.
V42 MODE
OFF MANDAT AUTO
MNP CLASS
DEC
5
INC
LAPM/MNP
DEC INC
BREAK:
DEC
NDT/NEXP
INC
V.42bis
ENABLE DISABLE
DTE-DCE
DEC
DCE-DTE
NONE
<1>
CTSon/off
DCE-DTE
DC1/DC2
<2>
DC1/DC3
RTS
INC DEC
CTS
INC
DATA FORMAT
TYPE LENGTH PAR
DATA FORMAT
SYNC ASYNC
PARITY:
DEC
Set automatically in
Hayes mode only.
NONE
INC
CHAR LENGTH
9 10 11
CARRIER DISC'T
ENABLE DISABLE
Hayes mode only: Use S register
S10 to change these options.
Continued from
SETUP
TEST
<4>
EIA MODEM
EIA
CTS CD
<1>
DSR
DSR to EIA
NORM TRUE XOVER
CD to EIA
NORM TRUE TOGGLE
CTS to EIA
NORM RTS TRUE
EIA
DTR ALBT
<2>
RDLT
EIA
TM
TM to EIA
NORMAL
<3> MODEM SETUPS
CDLVL
<1>
TXLVL
TRUE
TRANSMIT LEVEL
LEASED DIAL
TX LEVEL (DL)
PROGPERMIS
TX LEVEL
DEC
0 dBm
INC
MODEM SETUPS
SQ
<2>
COMEQ TREL
MODEM SETUPS
TXCLK T1
<3>
RETRN
TRANSMIT CLOCK
INT RX-CLK EXT
T1 timer: 0.8sec
DEC INC
AUTO-RETRAIN
ENABLE DISABLE
MODEM SETUPS <4>
ANS/ORGANSFREQ
ANSWER TONE
2225Hz 2100Hz
ANS/ORG DEFAULT
ANSWER ORIGINATE
MODEM SETUPS
FP
<5>
SPK SPKVOL
These screens are only displayed on models that support these options. MODEM SETUPS screens may be numbered differently.
MODEM SETUPS
GUARD
<6>
V13
V.13
DEC
GUARD TONE
OFF 550Hz 1800Hz
OFF
INC
MODEM SETUPS
PSWD
<7>
TRAIN
TRAINING LENGTH
LONGSHORT TER
PASSWORD
CHANGE CLEAR
CTS
RTS
MODEM SETUPS <8>
CARR CTS RTS-CTS
CARRIER
SWITCH CONSTANT
ON
SETUP <5>
PHONE AUTO LCDI
LCD INTENSITY 5
DEC INC
SETUP
SUMMARY
<6>
SUMMARY
SETUPS AT
314E
S-REG
Checksum.
If this number changes, at least one option has been changed.
AUTO-RECOVERY
SELECT RETN TEST
RETURN:
DEC
PRI addr
0011214E0 999 99
TEST EVERY 20min
DEC INC
OFF
INC
S-REG
DEC
00:01
INC
AT PROFILES
0 1 &Y0
ATbefImqvwxy
0102101341
AT&c
Pushing 3 changes from &Y0 to &Y1
TEST OPTIONS
DSR
DSR during ALB
ON OFF
RMT
REMOTE TEST
ENABLE
DTR from EIA
NORMAL TRUE
DISABLE
RDL - DTE Ctrl'ed
ENABLE DISABLE
ALB - DTE Ctrl'ed
ENABLE DISABLE
CARRIER DET.
LEASED
LVL
DIAL
CD LEVEL DIAL
-26 -33 -43
CD LEVEL LEASED
-26 -33 -43
TRELLIS CODE
ENABLE DISABLE
COMPR EQUAL
DEC
T-III
INC
SIGNAL QUALITY
10^3 10^5
SPEAKER VOLUME
LOW MEDIUM HIGH
SPEAKER CONTROL
OFF TILL-CD ON
FP
ENABLE DISABLE
CONFIRM
CTS DELAY: 0 ms
DEC INC
NO AUTO-RECOVERY
DEC INC
DEC SKIP INC
Use INC (increase) and DEC (decrease) to cycle through digits (0-9); use CTRL to cycle through dialing control characters(T, *, #, etc.).
PHONE CELL:
DEC
00
PROGINC
301-555-1234
DEC CTRL INC
ATbefImqvwxy
0102101341
AT&c
These screens allow for quick option selections.
(Use arrow pushbuttons to view full display.)
For further explanation, see Instruction Manual, appendix C, Summary Setup.
Power-on Screen
V.32bis/14.4M
V.32
V4.51/3.25
D TR MR RS CS TD
9600 TM ER CD RD
QUALITY
Bar graph
Software revision levels (may be different than shown here.)
MAIN MENU <1>
TALK QUICK DIAL
000
STATUS SCREENS
LINE LEVELS. dBm
TX=-09 RX=-24
ECHO: msec
020
Hz CHANNEL FREQ
1.0
OFFSET: 1.0 Hz
THROUGHPUT
15000 BPS
MAIN MENU
SETUP TEST
<2>
RMT
*
AUTO-DIAL
DIAL CELL HANGUP
DIAL FAILURE
NO DTR
DIAL CELL:
DEC DIAL e00
INC
This screen appears only in the event of a dial failure. Specific message appears on bottom line.
MANUAL-DIAL
TALK DATA
*
PKT: SIZE
255
TX
0233
ER
00
MODE RATE
V42bis 38400
MAIN MENU
RESET RATE
<3>
REMOTE
CONTROL
<1>
TEST
REMOTE TEST
RDL RDLST
REMOT DIGIT LOOP
ON OFF
V.32/14.4M.
RDL SELFTEST
ON OFF
Use pushbutton 2 to toggle between ADDR/C and SLOT/C.
REMOTE <2>
CTRL ADDR/C ADDR
ADDRESS :
DEC
999,999
INC
*
(Resets modem. LCD returns to power-on screen, then EIA status screen.)
If SLOT/C is selected from REMOTE screen
2 (above), the top line here will read SLOT
NUMBER: 01.
CHECKSUM
MAIN PUMP
(Accessed by pressing 1 from EIA status screen.)
MAIN
V3.02.02
m1_mt9bf2
19BB
Pump U51
V2.03.1
U52
C5E8
280C
Data displayed here is for use by servicing personnel.
Screens show software revision levels and various checksums for both the main processor and the data pump (transmitter, T, and receiver, R). It is unlikely that the numbers on your unit will match those shown here—this is normal.
LOCAL TEST
ALB ALBST
<1>
ST/E
ANALOG LOOPBACK
ON OFF
ANALOG SELFTEST
ON OFF
LOCAL TEST <2>
DLB ALBX ALXST
DIGITAL LOOPBACK
ON OFF
ANALOG LOOP (EXT)
ON OFF
SELFTEST w/ERROR
ON OFF
ANALOG ST (EXT)
ON OFF
Note: When a test is activated, the EIA status screen will be displayed.
© Copyright 2002. Black Box Corporation. All rights reserved.
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 1. Specifications
- 14 2. Quick Start
- 14 2.1 Installation
- 14 2.1.1 Unpacking
- 15 2.1.2 Connections
- 16 2.1.3 Jumpers
- 17 2.2 Front-Panel LCD and Controls
- 18 2.2.1 Power-On Screen
- 18 2.2.2 EIA Status Screen
- 19 2.3 Quick Setup
- 19 2.3.1 How to Select a Quick Setup
- 26 2.4 Basic Operation
- 26 2.4.1 2-Wire Dial Hayes Mode (Quick Setup 1)
- 27 2.4.2 2-Wire Dial V.25 bis Mode (Quick Setup 2-4)
- 28 2.4.3 2-Wire Dial Dumb Mode (Quick Setup 5)
- 30 2.5 Leased Line (2- or 4-Wire) Mode (Quick Setup 6-9)
- 30 2.6 V.33 Leased Line Operation (Quick Setup 10)
- 31 2.7 2-Wire Dial Bell 208 Operation (Quick Setup 11-12)
- 32 2.8 Two Types of Bell 208 Operation
- 32 2.8.1 Bell 208 Operation (Exclusive)
- 33 2.8.2 V.32/208 Auto-Select Mode
- 33 2.9 4-Wire Leased Line V.29 Mode (Quick Setup 13)
- 34 2.9.1 V.32 Dial Backup
- 34 2.10 V.29 Fast Master and Slave Modes (Quick Setup 14-15)
- 36 2.11 If You Have Problems
- 36 2.11.1 All Modes
- 36 and V.32/208)
- 38 2.11.3 All Asynchronous Modes
- 38 2.11.4 Hayes Mode
- 38 and V.29)
- 38 2.11.6 Leased Line (Excluding V.33 and V.29 Operation)
- 39 3. Options: Customizing the Modem Setup
- 39 3.1 Methods for Selecting Options
- 39 3.2 Front-Panel Options
- 39 3.2.1 Pushbuttons and the LCD
- 41 3.3 Selecting Options from the Front Panel
- 42 3.3.1 DEC/INC (Decrease/Increase) Screens
- 43 3.3.2 Example of How to Select an Option
- 44 3.3.3 How to Return to the EIA Status Screen
- 44 3.3.4 Automatic Configuration Save Feature
- 44 3.3.5 How to Return to Default Settings
- 45 3.4 Options
- 45 3.5 Speed (Data Rate) Options
- 49 3.6 V.42 Error Correction Options
- 55 3.7 Address
- 56 3.8 Dialer Mode
- 56 3.9 Auto-Answer Option
- 57 3.10 Data Format Options
- 58 3.11 Disconnect Options
- 59 3.12 Test Options
- 59 3.13 EIA Options
- 61 3.14 Modem Setups
- 66 3.15 V.33 and Bell 208A/B Options
- 68 3.16 Options Accessible Only via Summary Setup
- 68 3.16.1 Dial Line Options
- 68 3.16.2 V.42 Error-Correction Options
- 70 3.16.3 Data Pump Options
- 71 3.16.4 Miscellaneous Options
- 75 4.0 General Operation and Special Features
- 75 4.1 Quick Reset
- 75 4.2 Storing Phone Numbers
- 75 4.2.1 Uses
- 76 4.2.2 How to Store a Phone Number
- 78 4.3 Automatic Fallback
- 78 4.3.1 Operating-Mode Fallback
- 80 4.3.2 Automatic Rate Adjustment
- 81 4.4 Dumb Mode and Bell 208 Operation
- 81 4.4.1 Manual Originate/Answer Operation
- 82 4.5 V.32/208 Auto-Detect Mode
- 82 4.5.1 V.32/V.32 bis Operation
- 83 4.5.2 Bell 208 Operation
- 83 4.5.3 Automatic Fallback
- 83 4.6 V.13 Operation
- 83 4.7 DTR Dialing
- 84 4.7.1 Dialing a Stored Number
- 84 4.7.2 Answer Mode Operation
- 84 4.8 Dial Line Auto-Recovery
- 84 Recovery
- 85 4.8.2 Recovery Procedure
- 85 4.9 Leased Line Auto-Recovery
- 86 4.9.1 Autodial Backup
- 86 4.9.2 Exit from Leased Line Auto-Recovery
- 87 4.9.3 Leased-Line Auto-Recovery Options
- 88 4.10 Modem Security Operation
- 88 4.11 Automatic Password Protection (APP)
- 90 4.12 Configuring Modems for APP
- 90 4.12.1 APP Without Callback
- 90 4.12.2 APP With Callback
- 90 4.12.3 Password Screens
- 91 4.12.4 Valid Password Characters
- 92 Callback Number
- 92 4.13 Disabling APP
- 92 4.13.1 Temporarily Disabling APP
- 93 4.13.2 Clearing the Password
- 93 4.14 Manual-Response Password Protection (MPP)
- 94 4.15 Commands for Enabling MPP
- 95 4.16 How to Use Password Commands
- 98 5. Hayes Emulation Mode
- 98 5.1 Hayes Mode Autodialer
- 98 5.1.1 Enabling the Hayes Mode Autodialer
- 98 5.1.2 Command Guidelines
- 100 5.2 Result Codes
- 101 5.3 Transmission Speed
- 102 5.4 Hayes Compatible Commands
- 108 5.5 S Registers
- 108 5.5.1 Reading and Setting Registers
- 109 5.5.2 S Register Functions
- 111 5.6 Saving Option Selections
- 112 5.7 Facsimile (Fax) Transmission
- 112 5.8 Hayes Mode Reference Tables
- 128 6. V.25bis Autodialer
- 128 6.1 Enabling the V.25bis Autodialer
- 128 6.1.1 Quick Setup
- 129 6.1.2 2=Dialer Mode (DIAL V.25 bis Screen)
- 129 6.1.3 DTR Dialing in V.25 bis Mode
- 129 6.2 V.25 bis Autodialer Commands
- 133 6.3 Dialing Parameters
- 135 6.4 V.25 bis Result Codes
- 137 6.5 Message Format
- 137 6.5.1 Asynchronous
- 137 6.5.2 Synchronous, Character-Oriented
- 138 6.5.3 Synchronous, Bit-Oriented
- 139 7. Diagnostics
- 139 7.1 When and Why to Test
- 139 7.2 Symptoms and Scope of the Problem
- 140 7.3 Physical Inspection
- 140 7.4 Overview of Modem Diagnostics
- 141 7.5 How to Select and Activate Tests
- 141 7.5.1 Front-Panel Control
- 141 7.5.2 Running Tests in Hayes Mode
- 141 7.5.3 Remote Test Control
- 141 7.6 Diagnostic Monitoring: Status Screens
- 141 7.6.1 EIA Status Screen
- 142 7.6.2 Other Status Screens
- 144 7.7 Rate Change Screen
- 145 7.8 Local Modem Diagnostics
- 145 7.8.1 Analog Loopback (ALB) Test
- 146 7.8.2 Analog Loopback Self-Test (ALBST)
- 148 7.8.3 Analog Loopback Self-Test with Errors (ST/E)
- 148 7.8.4 External Analog Loopback (ALBX) Test
- 150 7.8.5 External Analog Loopback Self-Test (ALXST)
- 152 7.8.6 Digital Loopback Test (DLB)
- 154 7.9 Remote Modem Diagnostics
- 154 7.9.1 Remote Digital Loopback (RDL) Test
- 155 7.9.2 Remote Digital Loopback Self-Test (RDLST)
- 157 Appendix A: Quick Setup Configurations
- 167 Appendix B: Summary Setup
- 167 B.1 Summary Setup LCD Screens
- 168 B.2 Changing Options via Summary Setup
- 168 B.2.1 Summary Setup Pushbutton Functions
- 169 B.2.2 Explanation of Summary Setup Screens
- 177 Appendix C: Connectors, Adapters, and Jumpers
- 178 C.1 Connectors and Adapters
- 179 C.1.1 Connector Pin Assignments
- 180 C.2 Jumpers
- 182 Appendix D: DC Voltage Models
- 182 D.1 Introduction
- 183 D.2 Installation
- 184 D.3 Jumper Settings
- 185 D.4 Jumper Locations
- 186 Appendix E: LCD Flow Chart