W E L LS M A N U FA CT U R I N G
W E L LS M A N U FA CT U R I N G
R
R
R
STD.4
E6070
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
BACK
1
(25)
57 1/2
(1461)
1/4 INCH
EXTERNAL NPT
WATER LINE
CONNECTION
35 1/16
(890)
Single Control Panel
SIDE
1
(25)
BOTTOM
6 3/4
(171)
R
R
LISTED
E6070
STD.4
R
E6070
DIMENSIONS:
INCH
(MM)
FRONT
6
(152)
6 1/4
(159)
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
BACK
1
(25)
71 1/2
(1816)
1/4 INCH
EXTERNAL NPT
WATER LINE
CONNECTION
35 1/16
(890)
FRONT
6
(152)
(159)
Single Control Panel
14
(356)
TYP
7 3/4
7 3/4
(197)
(600)
2 1/4
(57)
9 3/4
1 3/4
(44)
1 3/4
14
(356)
1 INCH
INTERNAL NPT
MANIFOLD EACH END
6 1/4
(159)
Double Control Panel
(44)
9 3/4
(248)
(248)
1/4 INCH
EXTERNAL NPT
WATER LINE
CONNECTION
14
35
(356)
(889)
6 1/4
(159)
1 INCH
INTERNAL NPT
MANIFOLD EACH END
M O D - 5 0 0 T D M E L E C T R I C A L S P E C I F I C AT I O N S :
AMPS PER LINE 3 PHASE
AMPS
POWER
VOLTS WATTS
SINGLE PHASE SUPPLY CORD
L1
L2
L3
MODELS
Lbs.
KG
19
21
9
10
41
51
19
23
64
78
29
35
81
98
37
44
97
118
44
54
Accessories / Options
Double Control Panel
M O D - 4 0 0 T D M E L E C T R I C A L S P E C I F I C AT I O N S :
OFF/LO to HI
MOD-100TD series:
Installed
Shipping
MOD-200TDM series:
Installed
Shipping
MOD-300TDM series:
Installed
Shipping
MOD-400TDM series:
Installed
Shipping
MOD-500TDM series:
Installed
Shipping
2 1/4
(57)
71 1/2
(1816)
Features
Weights:
23 5/8
(600)
57 1/2
(1461)
Specifications
Temperature Settings:
23 5/8
18
(457)
BOTTOM
6 3/4
(171)
MOD-100TD, 200TDM, 300TDM, 400TDM, 500TDM
WARMERS WITH AUTO WATER FILL
6 1/4
(197)
1/4 INCH
EXTERNAL NPT
WATER LINE
CONNECTION
SIDE
1
(25)
ITEM NO.
MOD-300TDM
14
(356)
TYP
MODEL
MOD-500TDM
WA R M E R W I T H A U T O WAT E R F I L L
AMPS PER LINE 3 PHASE
AMPS
POWER
VOLTS WATTS
SINGLE PHASE SUPPLY CORD
L1
L2
L3
Wellslok Extension Kit, designed for installation
in countertops up to 1-1/2” thick, refer to
installation instructions, 22593
• All models have an automatic water fill
system that maintains the proper water level in
each pan through the use of a water sensor and
solenoid valve.
• Individual controls for each well give the
warmers maximum versatility.
• Thermostats are combined with higher wattage
elements to provide quicker heat-up and
faster recovery.
• Fully insulated for greater efficiency.
• A one-inch diameter drain manifold
(DM models) is provided to allow for a single
drain connection at the left or right front corner.
MOD-100TD has a one-half inch drain.
• Each well is one-piece, deep-drawn, stainless
steel for maximum strength and durability.
• Warmers are designed for wet operation only.
• Wellslok allows for quick and easy installation
in stainless steel countertops.
MOD-400TDM/AF 208
4960
14.5
14.5
9.8
23.8
NONE
MOD-500TDM/AF 208
6200
19.5
14.6
14.6
29.8
NONE
Drain Valve Extension Kit, extension from
drain to counter front with remote handle,
for use with MOD-100TD only, 20385
MOD-400TDM/AF 240
6600
17.8
17.8
11.3
27.5
NONE
MOD-500TDM/AF 240
8250
22.1
16.9
16.9
34.4
NONE
Drain Screen, 21709
• The MOD Series Warmers are Underwriters
Laboratories, Inc. LISTED and meet NSF
International and Canadian standards.
Optional 72” Wiring, thermostatically controlled
warmers, priced per well, contact factory
• A one-year warranty against defects covers
parts and labor.
MODELS
NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit.
This document is not for installation purposes.
NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit.
This document is not for installation purposes.
WELLS MANUFACTURING COMPANY
02/02 • REV(-) • PART NO. 303438
2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A.
USA PHONE: (775) 345-0444 • FAX: (775) 345-0569
FOR ORDERS ONLY: (888) 356-5362 • FAX: (800) 356-5142
www.wells-mfg.com
© 2002 WELLS MANUFACTURING • PRINTED IN THE U.S.A.
02/02 • REV(-) • PART NO. 303438
Explanation of Built-In Warmer Suffixes:
TD ............. thermostatically controlled/with drain
TDM ......... thermostatically controlled/with drain/
connected to drain manifold
WELLS
MOD-100TD - MOD-500TDM WARMERS WITH AUTO WATER FILL
LISTED
E6070
MODEL
MOD-400TDM
WA R M E R W I T H A U T O WAT E R F I L L
W E L LS M A N U FA CT U R I N G
R
R
LISTED
E6070
STD.4
MODEL
M O D-100TD
WA R M E R W I T H A U T O WAT E R F I L L
R
E6070
INCH
(MM)
DIMENSIONS:
W E L LS M A N U FA CT U R I N G
W E L LS M A N U FA CT U R I N G
W E L LS M A N U FA CT U R I N G
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
BACK
1
(25)
SIDE
1
(25)
BOTTOM
6 3/4
(171)
FRONT
4 1/8
(105)
R
R
LISTED
E6070
STD.4
MODEL
MOD-200TDM
WA R M E R W I T H A U T O WAT E R F I L L
R
E6070
DIMENSIONS:
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
INCH
(MM)
BACK
1
(25)
SIDE
1
(25)
BOTTOM
6 3/4
(171)
R
R
LISTED
E6070
STD.4
MODEL
MOD-300TDM
WA R M E R W I T H A U T O WAT E R F I L L
R
E6070
DIMENSIONS:
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
FRONT
4 1/8
(105)
BACK
1
(25)
SIDE
1
(25)
BOTTOM
6 3/4
(171)
FRONT
4 1/8
(105)
14
(356)
2 1/4
(57)
14
(356)
23 1/2
(597)
2 1/4
(57)
7 3/4
TYP
(197)
23 5/8
(600)
2 1/4
(57)
7 3/8
23 5/8
(600)
7 3/4
(197)
(187)
29 1/2
(375)
1/4 INCH
EXTERNAL
NPT WATER
LINE CONNECTION
6 1/4
(159)
6 1/4
(159)
1 3/4
(44)
1/4 INCH
EXTERNAL NPT
WATER LINE
CONNECTION
1 3/4
(44)
1 INCH
INTERNAL NPT
MANIFOLD EACH END
18
(457)
M O D - 2 0 0 T D M E L E C T R I C A L S P E C I F I C AT I O N S :
VOLTS
WATTS
AMPS
PHASE
POWER SUPPLY CORD
MOD-100TD/AF
208
1240
6.0
SINGLE
NONE
MOD-100TD/AF
240
1650
6.9
SINGLE
NONE
NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit.
This document is not for installation purposes.
02/02 • REV(-) • PART NO. 303438
(248)
9 3/4
(248)
1/2 INCH
INTERNAL NPT
14
(356)
6 1/4
(159)
9 3/4
9 3/4
(248)
M O D - 1 0 0 T D E L E C T R I C A L S P E C I F I C AT I O N S :
MODELS
43 1/2
(1105)
(749)
14 3/4
MODELS
VOLTS WATTS
1/4 INCH
EXTERNAL NPT
WATER LINE
CONNECTION
1 INCH
INTERNAL NPT
MANIFOLD EACH END
35
(889)
1 3/4
(44)
M O D - 3 0 0 T D M E L E C T R I C A L S P E C I F I C AT I O N S :
AMPS PER LINE 3 PHASE
AMPS
POWER
SINGLE
PHASE
SUPPLY
CORD
L1
L2
L3
MODELS
VOLTS WATTS
AMPS PER LINE 3 PHASE
AMPS
POWER
SINGLE PHASE SUPPLY CORD
L1
L2
L3
MOD-200TDM/AF 208
2480
6.0
10.3
6.0
11.9
NONE
MOD-300TDM/AF 208
3720
10.3
10.3
10.3
17.9
NONE
MOD-200TDM/AF 240
3300
6.9
11.9
6.9
13.8
NONE
MOD-300TDM/AF 240
4950
11.9
11.9
11.9
20.6
NONE
NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit.
This document is not for installation purposes.
02/02 • REV(-) • PART NO. 303438
NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit.
This document is not for installation purposes.
02/02 • REV(-) • PART NO. 303438