CanWorks® Operator Interface Tracking PLUS
Introduction
This instruction sheet covers installation of the
Echelon SLTA-10 network adapter and drivers and
the CanWorks® Operator Interface (OI) Tracking PLUS
software. Because the OI must be configured to use
the network adapter before you can configure the
SM-1 or SM-2 modules on the network, install the
network adapter and drivers first.
E
SLTA-10 Adapter Installation
LE
T
Remove the SLTA-10 adapter from its packaging.
Included with the adapter is a serial cable.
Dipswitch Settings
BS
O
There are 8 dipswitches on the adapter’s switch
block. Set the switches as follows:
UP
ON
O
DOWN
1
OFF
2
3
4
5
6
7
8
1439001A
Fig. 1 Dipswitch Settings
Switch
Position
1
Off/Down
2
Off/Down
3
Off/Down
4
On/Up
5
Off/Down
6
On/Up
7
On/Up
8
On/Up
1
CanWorks® Operator Interface Tracking PLUS
Adapter Connections
1. Plug one end of the included serial cable into the
adapter’s EIA-232 port and the other end into the
PC’s serial port (COM port). Make a note of which
port you use.
2. See Figure 2. Connect the network wiring to the
adapter terminal block labeled NETWORK. Use
twisted-pair shielded wire (Belden 8773 or
equivalent). Refer to the applicable CanWorks
Spray Monitor I or CanWorks Display Module
manuals for more information.
BS
O
LE
T
E
NOTE: The network must be terminated at each end. If
you must connect the network adapter to one end of the
network, install a 121 ohm, 1%, 1/8 watt metal film resistor
across the network adapter terminals as shown in Figure 2.
1
O
4
3
2
3
2
1439002A
Fig. 2 Network Connections
1. Display module
2. SM-1/SM-2 modules
3. SLTA-10 network adapter
4. Resistor (use only if adapter
is on end of network)
2
CanWorks® Operator Interface Tracking PLUS
3. Connect power leads from the CanWorks system
to the adapter’s POWER terminal block. The terminals have no polarity. Voltage should be 24 ± 4
Vdc.
Software Installation and Configuration
LE
T
Software Installation
E
Software installation and configuration consists of
installing the network adapter drivers and Link
Manager; and the OI, then configuring the Link
Manager and OI. You do not have to have the network
adapter connected to the CanWorks network to install
the software.
O
BS
O
1. Insert the CanWorks OI CD into your CD-ROM
drive. After a few seconds pause, the installation
menu should appear. If it does not, enable
Autoplay in Windows, then re-insert the CD. Refer
to Enabling Autoplay in this guide for instructions.
2. Click on the Install Drivers button to install the
SLTA-10 network adapter drivers and SLTALink
Manager program.
At all prompts, click Next to accept and use the
default settings. Answer No when the install
program asks you if you want to install additional
DOS and 16 bit drivers.
When the install program is finished, DO NOT let it
reboot Windows. Instead, exit the install program
and go on to the next step.
3. Click on the Install OI button and follow the
installation instructions. When the install program
is finished, configure the SLTALink Manager.
3
CanWorks® Operator Interface Tracking PLUS
SLTALink Manager Configuration
Before starting the OI, you must configure the
SLTALink Manager program and set up link associations.
O
BS
O
LE
T
E
1. Start the SLTALink Manager from your
Start>Programs>Echelon SLTA-10 Network
Adapter menu.
2. Click on Link>Select/Action.
3. From the Link Selection dialog box, select LOCAL
SLTA-10. Click on the Edit button.
4. Click on the Next button and make sure the COM
port you plugged the adapter serial cable into is
selected, and that 115200 baud is selected. Click
on the Next button.
5. Select either LONSLTA.0 or LON1 under Device
Assignment.
6. Click on Finish, then click on OK.
7. Click on Devices>Link Associations.
8. Make sure that either LONSLTA.0 or LON1
appears in the Device field.
9. Click on the down arrow in the Default Link field
and select LOCAL SLTA-10.
10. Click on OK.
11. Reboot your PC to activate the changes before
running the OI. The Link Manager and OI will start
when Windows starts, and an icon for the Link
Manager should appear in the Windows taskbar,
at the bottom of your desktop.
OI Configuration
Before the OI can communicate with the SM-1 or
SM-2 modules on the network, you must configure
the network address and device name. The OI starts
when Windows starts.
4
CanWorks® Operator Interface Tracking PLUS
Enabling Autoplay
LE
T
E
1. Log onto the OI with supervisor-level access. Click
on Help>Help Topics and select Initial Logon under
Security Administration to learn how to do this.
2. Click on Tools>Options. Click on the Display tab.
3. Select an address for the OI that is not being used
by another device on the CanWorks network. Use
the up and down arrows in the field to change the
address number.
4. Click on the down arrow in the Device Name field
and select SLTALON1 for the adapter device
name. It should be the only name available.
5. Click on OK to save the settings.
6. Click on File>Exit to exit the OI, then restart the OI
from the icon on your desktop. You must restart
the OI for the changes you made to take effect.
BS
O
Follow these instructions to make CDs play automatically when you insert them in your CD drive.
O
1. Open the Control Panel and double-click on the
System icon. Click on the Device Manager tab.
2. Click on the plus sign next to CDROM, right-click
on your CD drive, then click on Properties.
3. Click on the Settings tab.
4. Select the Auto insert notification check box. A
check mark appears in the box when Autoplay is
enabled.
5. Click on OK.