ClearOne LS6CT Ceiling Speaker
InstallatIon InstructIons
I
NSTALLATION
I
NSTRUCTIONS
ClearOne Ceiling Speaker
1. Take the cutout template from the packaging box and punch out along the larger perforated circle. Place the cutout template against the bottom of the ceiling and trace the inside.
Carefully cut out the ceiling material along the circle.
3. Loosen the four screws on the front baffle
(counter clockwise) a 1/2 turn. Tighten the screws (clockwise) until the dog legs clamp the speaker to the ceiling.
CAUTION: Do not over tighten screws.
4. Connect a secondary support line from the seismic tab to a secure support point. Set the rotary tap selector and install the speaker grille.
2. Remove the top cover to access the speaker wires. Use wire nuts to connect the speaker wires connecting the positive signal to the red wire and the negative signal to the black wire.
Install the conduit and secure the connections.
© 2009 ClearOne Communications, Inc. All rights reserved. Information in this document is subject to change without notice. Other product names may be registered trademarks of their respective owners who do not necessarily endorse ClearOne or ClearOne’s products in the United States and/or other countries. C learOne Document: 800-151-000 Revision 1.5 July 2009.
Specifications:
Acoustic and Electrical
Speaker type
Frequency range
Power handling
2-way, ceiling speaker with metal back can
65 Hz to 20 kHz,
60 Watts RMS
120 Watts PEAK
88 dB, 1W@1m Nominal sensitivity
Nominal coverage angle
110° conical coverage
Nominal impedance 8 ohms
Transformer taps
70V:: 30W, 15W, 7.5W,
3.8W, 1.9W, 8 ohms 100: null, 30W, 15W, 7.5W, 3.8W,
8 ohms
Woofer
Tweeter
Overload protection
6.5" (165 mm) polypropylene cone with moisture resistant coating
3/4" (19 mm) silk dome
Full range power limiter with the 8 ohm direct input only, protecting the tweeter, woofer, and crossover.
General
Temperature/Humidity
Listings
Compliances
Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating:
+32 to +122 °F (0 to +50
°C) / 10% to 90%, noncondensing
UL1480
CE
NOTE: All nominal levels are at ±10%.
NOTE: Specifications are subject to change without notice.
© 2009 ClearOne Communications, Inc. All rights reserved. Information in this document is subject to change without notice. Other product names may be registered trademarks of their respective owners who do not necessarily endorse ClearOne or ClearOne’s products in the United States and/or other countries. C learOne Document: 800-151-000 Revision 1.5 July 2009.