Please read this owner s manual carefully and
Chapter 4 Troubleshooting Guide
13
14
15
10
11
12
4
5
2
3
6
7
8
9
F0
F1
F2
F3
E2
E3
E4
E5
F7
F8
F9
F4
F5
F6
4.1 Error Code
No.
Error Code
1
E1
16
FA
Problem
Room temperature sensor fault
Outdoor coil temperature sensor fault
Indoor coil temperature sensor fault
Indoor fan motor or DC motor feedback fault
Indoor & outdoor communication fault
Outdoor DC Fan motor fault
IPM modular fault
PFC modular fault
Compressor operation fault
Exhaust Temperature sensor fault
Compressor top cover protection
Outdoor ambient temp sensor fault
Over/under voltage protection
Outdoor modular communication fault
Outdoor E²PROM fault
Suction temperature sensor fault
(4-way valve swich failure)
10
4.2 Troubleshooting Guide
1. The Foremost Inspecting Items
⑴
The input voltage must be within +10% tolerance of the rated Voltage. If it is not the case, the air-conditioner will probably not work normally.
⑵
Check the connecting cord between indoor unit and outdoor unit to see if it is properly connected. The connecting must be done according to the wiring diagram, please also notice that even different models may have the connecting cord of the same specification.
Please check if the marks at the connecting terminal and the marks on the cord can match, otherwise, the air-conditioner will not work normally.
⑶
If the following phenomena are found, the problem is not from the air-conditioner itself.
11
NO.
1
2
3
4
5
Problems
The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on
The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.
The compressor works discontinuously at dehumidifying mode.
The air-conditioner does not work while the LED display is on.
The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.
Causes
Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the Signal is well received.
If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.
The air-conditioner will automatically control the working of the compressor according to the inside temperature
The TIMER is set with the air-conditioner; it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition
The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.
12
2. No Power Display
⑴Items
a) Check if the input voltage is correct?
b) Check if the AC power supply connecting is correct?
c) Check if the output voltage of the manostat L7805 (IC2) is correct?
⑵Trouble shooting procedure
13
3. The Indoor Fan Motor Does Not Work
⑴Items
a) Check if the indoor fan motor is connected correctly to the connector (CN8)?
b) Check if the AC input voltage is correct?
c) Check if the IC of indoor fan motor is connected correctly to the connector
(CN2)?
d) Check if the capacity of indoor fan motor is connected correctly to the connector (CN8)?
⑵Trouble shooting procedure
14
4. The Outdoor Unit Does Not Work
⑴Items
a) Check if the input voltage is correct?
b) Check if the wire connection of the outdoor connecting terminal is correct?
⑵Trouble shooting procedure
15
5. The Step Motor Does Not Work
⑴Items
a) Check if the input voltage is correct?
b) Check if the step motor controlling the up-down movement firmly connected to Cn2?
⑵Trouble shooting procedure
16
6. Heating Mode Can Work, But No Hot Air Blow
⑴Check if the set temperature is lower than the indoor temperature?
⑵Check if the indoor PCB is connected to the terminal correctly?
17
7. Remote Control Can Not Work
Trouble shooting rocedure
18
e l a re lo o a re ere ra e ar o l a re Pro c c o r 201 l a re Pro c c