Viking DCWH Classic Chimney Installation guide

Add to my manuals
24 Pages

advertisement

Viking DCWH Classic Chimney Installation guide | Manualzz

Viking Installation Guide

Viking Range Corporation

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com

F20470I EN (082012)

Professional &

Outdoor Hoods

Table of Contents

Warnings & Important Information_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3-4

VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”

Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5

Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6

Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7

VWH 18”H. 24”/27” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”

Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8

Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9

Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 10

Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 11

VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”

Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 12

Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 13

VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”

Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 14

Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 15

Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 16

Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 17

DCWH Classic Chimney Hoods 30”, 36”, 42”, & 48”

Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 18

Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 19

Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 20

Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 21

VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”

Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 22

Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 23

Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 24

Exterior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 25

VBCV Wall Custom Ventilator System

Dimensions & Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 26

Installing Hood Canopy _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 27

Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 28

VBCV Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 29

Planning Information_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 31

Installation Procedures

Installation (VWH 10”H. Wall Hoods w/Standard Ventilator) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 32

Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34

Installation (VWH 10”H. Wall Hoods w/Recirculating Kit) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 34

Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 37

Duct Cover Option (VWH 18”H. Wall Hoods)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 38

Duct Cover Option (VCWH Chimney Wall Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 39

Installation (VCIH Island Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 40

Installation (DCWH Classic Chimney Hoods) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 42

Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 44

Wiring Diagram _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 45

2

IMPORTANT– Please Read and Follow!

NOTE: If installing hood with warming shelf panel, install warming shelf panel first.

W A R N I N G

IMPORTANT – PLEASE READ AND FOLLOW

• Before beginning, please read these instructions completely and carefully.

• Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.

• Please observe all local and national codes and ordinances. If no local codes are applicable, wire in accordance with the National Electrical Code,

ANSI/NFPA 70-latest edition.

• Damp environment approved models should be installed in a covered non-enclosed area and should be protected from the elements as much as possible.

• The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.

• Check with a qualified and trained installer or local codes for makeup air requirement, if any.

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

W A R N I N G

This hood is for residential installation only and is not designed for installation over a commercial product. Make sure power is off at the main circuit breaker or fuse box before making connections. To avoid risk of fire, electric shock, or injury to persons, turn off the electricity to the hood from the power supply before servicing or cleaning.

Viking hoods are equipped with variable speed control blowers. These units will not function with a single speed ventilator. All Viking Range ventilator kits are designed specifically for use with Viking Range hoods. Use of any non-Viking Range ventilator kit will void the hood warranty.

Viking hoods are equipped with the variable speed controls for blowers. These units will not function with a single speed ventilator. All Viking ventilator kits are designed specifically for use with Viking hoods. Use of any non-Viking ventilator kit will void the hood warranty.

READ AND SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRICAL

SHOCK, OR INJURY TO PERSONS, OBSERVE

THE FOLLOWING:

1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

2. Sufficient air is needed for proper combustion and exhausting of gases through the flute

(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire

Protection Association (NFPA), and the

American Society for Heating, Refrigeration and

Air Conditioning Engineers (ASHRAE), and the local code authorities.

3. When cutting of drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

4. Ducted fans must always be vented to the outdoors.

5. WARNING!: To reduce risk of fire, use only metal ductwork

6. CAUTION!: To reduce risk of fire and to properly exhaust air, be sure to duct air outside.

Do not vent exhaust air into spaces within walls or ceilings, or into attics, crawl spaces, or garages.

7. CAUTION!: To Reduce the Risk of Fire and

Electric Shock, Install this rangehood only with remote blower models manufactured by Viking, model numbers – DEV900/DEV1200,

VEV900/VEV1200, OR DEV1500, VEV1500 or integral blowers manufactured by Viking, model numbers – DIV300, DIV440, DIV600, DIV800,

DIV1200, VIV300, VIV600, or VIV1200. NOTE –

Please refer inside for specific canopy/blower combinations.

3

IMPORTANT– Please Read and Follow!

W A R N I N G

To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.)

1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE

CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL

THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN. You may be burned.

3. DO NOT USE WATER, including wet dishcloths or towels a violent steam explosion will result.

4. Use an extinguisher ONLY if

• You know it is a Class ABC extinguisher, and you already know how to operate it.

• The fire is small and contained in the area where it started.

• The fire department is being called.

• You can fight the fire with your back to an exit.

C A U T I O N

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

W A R N I N G

TO REDUCE THE RISK OF FIRE,

ELECTRICAL SHOCK, OR INJURY

TO PERSONS

Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted.

4

Dimensions & Specifications

(VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”)

NOTE: Optional duct cover sold separately.

VWH 10”H. Wall Hoods w/Standard Ventilator

Description 24” 30” 36”

Duct cover width

Duct cover depth

Duct cover height

Number of lights

Number of filters

Heat lamps

Interior ventilator kit

Interior duct size*

Interior—Maximum amps

23-7/8” (60.6 cm) 29-7/8” (75.9 cm)

12” (30.5 cm)

12” (30.5 cm)

2

2

N/A

460 CFM Standard

7” (17.8 cm)

5.6

35-7/8” (91.1 cm)

* Disregard when using recirculating kits.

460 CFM blower is shipped with hood.

5

Clearance Dimensions

(VWH 10”H. Wall Hoods w/Standard Ventilator)

Interior Ventilator Dimensions

(VWH 10”H. Wall Hoods w/Standard Ventilator)

Top View

460 CFM Interior Ventilator Installation

7 6

Dimensions & Specifications

(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)

(VWH 18”H. 27” Deep Wall Hoods 36”, 48”, & 60”)

Clearance Dimensions

(VWH 18”H. Wall Hoods)

NOTE: Optional duct cover sold separately.

Description

Duct cover width

Duct cover depth

Duct cover height

Number of lights

Number of filters

Heat lamps

Interior ventilator kits

Exterior ventilator kits

In-line ventilator kits

Interior duct size

Exterior duct size

Interior—Maximum amps

Exterior—Maximum amps

In-Line—Maximum amps

30”

VWH 18”H. Wall Hoods

36” 42” 48”

29-7/8”

(75.9 cm)

35-7/8”

(91.1 cm)

41-7/8”

(106.4 cm)

47-7/8”

(121.6 cm)

2

2

1

VINV300/

600/1200

DEV900/

1200*

DIL900/1200

7”/10”

(17.8/25.4 cm)

4.9/5.9

8.7/6.0

6.0/7.9

2

2

1

VINV300/

600/1200

DEV900/

1200*

DIL900/1200

7”/10”

(17.8/25.4 cm)

4.9/5.9

8.7/6.0

6.0/7.9

2

2

12” (30.5 cm)

12” (30.5 cm)

1

VINV600/

1200

DEV900/

1200*

DIL900/1200

3

3

2

VINV1200*

DEV1200*/

1500**

DIL1200

7”/10”

(17.8/25.4 cm)

10” (25.4 cm)

10”

(25.4 cm)

11.5

8.7/6.0

6.0/7.9

11.5

8.5/9.2

10.3

54” 60”

53-7/8”

(136.8 cm)

59-7/8”

(152.1 cm)

3

3

2

VINV1200*

DEV1200*/

1500**

DIL1200

10”

(25.4 cm)

11.5

8.5/9.2

10.3

4

4

2

VINV1200*

DEV1200*/

1500**

DIL1200

10”

(25.4 cm)

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.

Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

11.5

8.9/9.2

10.7

8 9

Interior Ventilator Dimensions

(VWH 18”H. Wall Hoods)

Top View

300 or 600 CFM Interior Ventilator Installation for all Wall Hoods

Top View

1200 CFM Interior Ventilator Installation for all Wall Hoods

10

Exterior Ventilator Dimensions

(VWH 18”H. Wall Hoods)

Top View

900 or 1200 CFM Exterior or In-Line Ventilator Installation for all

Wall Hoods

Top View

1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all

Wall Hoods

11

Dimensions & Specifications

(VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)

Clearance Dimensions

(VWHO 18”H. Outdoor Wall Hoods)

NOTE: Optional duct cover sold separately.

Description

Duct cover width

Duct cover depth

Duct cover height

Number of lights

Number of filters

Interior ventilator kits

Exterior ventilator kits

In-line ventilator kits

Interior duct size

Exterior duct size

Interior—Maximum amps

Exterior—Maximum amps

In-Line—Maximum amps

VWHO 18”H. Outdoor Wall Hoods

36” 48”

35-7/8” (91.1 cm)

60”

59-7/8” (152.1 cm)

2

2

VINV1200*

DEV1200*/1500**

DIL1200

9.0

6.1/6.8

7.9

47-7/8” (121.6 cm)

12” (30.5 cm)

12” (30.5 cm)

3

3

VINV1200*

DEV1200*/1500**

DIL1200

10” (25.4 cm)

10” (25.4 cm)

11.4

8.4/9.1

10.2

4

4

VINV1200*

DEV1200*/1500**

DIL1200

11.8

8.8/9.5

10.6

* A 1,200 CFM interior- or exterior-power ventilator should be used with all outdoor models and when i ndoor models are installed over range/rangetop with gas char-grill. Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

12

Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from the elements as much as possible.

The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the back wall. (Note: There is a 3” minimum clearance from the back trim to non-combustible surfaces, and a 24” minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible material used for this purpose must be covered with locally-supplied stainless steel. Viking also recommends using a backsplash.

13

Dimensions & Specifications

(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”)

Clearance Dimensions

(VCWH Chimney Wall Hoods)

NOTE: Optional duct cover sold separately.

VCWH Chimney Wall Hoods

Description 30” 36” 42” 48” 54” 60” 66”

Duct cover width

Duct cover depth

Duct cover height

Number of lights

Number of filters

12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 18” (45.7 cm) 24” (61.0 cm) 24” (61.0 cm)

2

2

2

2

12” (30.5 cm)

12” (30.5 cm) to 24” (61.0 cm)

2

2

3

2

3

3

4

3

4

3

Heat lamps

Interior ventilator kits

Exterior ventilator kits

In-line ventilator kits

Interior duct size

Exterior duct size

Interior—Maximum amps

Exterior—Maximum amps

1 1 1

VINV300/600 VINV300/600 VINV600

DEV900/

1200*

DEV900/

1200*

DEV900/

1200*

DIL900/1200 DIL900/1200 DIL900/1200

2

VINV1200*

DEV1200*/

1500**

DIL1200

2

VINV1200*

DEV1200*/

1500**

DIL1200

2

VINV1200*

DEV1200*/

1500**

DIL1200

2

VINV1200*

DEV1200*/

1500**

DIL1200

7” (17.8 cm) 7” (17.8 cm) 7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm) 10” (25.4 cm)

4.9/5.9

8.7/6.0

4.9/5.9

8.7/6.0

5.9

8.7/6.0

10” (25.4 cm)

11.5

8.5/9.2

11.5

8.5/9.2

11.9

8.5/9.2

11.9

8.5/9.2

In-Line—Maximum amps 6.0/7.9

6.0/7.9

6.0/7.9

10.3

10.3

10.7

10.7

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.

Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

14 15

Interior Ventilator Dimensions

(VCWH Chimney Wall Hoods )

Top View

300 or 600 CFM Interior Ventilator Installation for 30”, 36”, & 42” models

Top View

1200 CFM Interior Ventilator Installation for 48”, 54”, 60”, & 66” models

16

Exterior Ventilator Dimensions

(VCWH Chimney Wall Hoods )

Top View

900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30”, 36”, & 42” models

Top View

900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 48”, 54”, 60”, & 66” models

17

Dimensions & Specifications

(DCWH Classic Chimney Hoods 30”, 36”, 42”, & 48”)

Clearance Dimensions

(DCWH Classic Chimney Hoods)

Description

Duct cover width

Duct cover depth

Duct cover height

DCWH Classic Chimney Wall Hoods

30”

10” (25.4 cm)

18” (45.7 cm) to

30” (76.2 cm)

2

2

VINV300/600

DEV900/1200*

DIL900/1200

7” (17.8 cm)

2.8/3.8

6.6/3.9

3.9/5.7

36” 42”

12” (30.5 cm) 12” (30.5 cm)

16” (40.6 cm) to

28” (71.1 cm)

2

2

VINV300/600

DEV900/1200*

12” (30.5 cm)

16” (40.6 cm) to

28” (71.1 cm)

2

3

VINV600

DEV900/1200*

DIL900/1200

7” (17.8 cm)

10” (25.4 cm)

DIL900/1200

7” (17.8 cm)

2.8/3.8

6.6/3.9

3.9/5.7

3.8

6.6/3.9

3.9/5.7

48”

18” (45.7 cm)

Number of lights

Number of filters

Interior ventilator kits

Exterior ventilator kits

In-line ventilator kits

Interior duct size

Exterior duct size

Interior—Maximum amps

Exterior—Maximum amps

In-Line—Maximum amps

16” (40.6 cm) to

28” (71.1 cm)

3

3

VINV1200*

DEV1200*/1500**

DIL1200

10” (25.4 cm)

7.3

4.3/5.1

6.1

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.

Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

18

NOTE: For best performance, it is recommended that the bottom of the hood be 30” (76.2 cm) to

36” (91.4 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood.

19

Interior Ventilator Dimensions

(DCWH Classic Chimney Hoods )

Top View

300 or 600 CFM Interior Ventilator Installation for 30”, 36”, & 42”Hoods

Top View

1200 CFM Interior Ventilator Installation for 48” Hoods

20

Exterior Ventilator Dimensions

(DCWH Classic Chimney Hoods )

Top View

900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30”, 36”, & 42” Hoods

Top View

900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 48” Hoods

21

Dimensions & Specifications

(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)

Clearance Dimensions

(VCIH Chimney Island Hoods)

NOTE: Optional duct cover sold separately.

Description

Duct cover width

Duct cover depth

Duct cover height

Number of lights

Number of filters

Heat lamps

Interior ventilator kits

Exterior ventilator kits

In-line ventilator kits

Interior duct size

VCIH Chimney Island Hoods

36”

12” (30.5 cm)

4

4

VINV600

DEV900/1200*

42” 54”

12” (30.5 cm) 18” (45.7 cm)

12” (30.5 cm)

12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)

4

4

6

6

N/A

VINV600

DEV900/1200*/1500**

VINV1200*

DEV1200*/1500**

DIL900/1200

7” (17.8 cm)

DIL900/1200

7” (17.8 cm)

DIL1200

10” (25.4 cm)

66”

24” (70.0 cm)

8

8

VINV1200*

DEV1200*/1500**

DIL1200

10” (25.4 cm)

Exterior duct size

Interior—Maximum amps

Exterior—Maximum amps

In-Line—Maximum amps

4.6

7.4/4.7

4.7/6.5

4.6

7.4/4.7/5.5

3.9/5.7

10” (25.4 cm)

8.9

5.6/6.4

7.4

9.3

6.4/7.4

7.4

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.

Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

22 23

Interior Ventilator Dimensions

(VCIH Chimney Island Hoods )

Top View

600 CFM Interior Ventilator Installation for all Chimney Island Hoods

Top View

1200 CFM Interior Ventilator Installation for all Chimney Island Hoods

24

Exterior Ventilator Dimensions

(VCIH Chimney Island Hoods )

Top View

900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Chimney Island Hoods

Top View

900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all Chimney Island Hoods

25

Dimensions & Specifications

(VBCV Wall Custom Ventilator System 30”, 36”, 42”, 48”, 54”, 60” & 66”)

*For best results, center the unit over the burners of the cooking product

(front to back; right to left).

Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 25.

Description

30” W.

36” W.

42” W.

48” W.

54” W.

60” W.

66” W.

Bottom Cutout Dimensions

Wall Hoods

A (Hood Width)

27-7/16” (69.7 cm)

33-7/16” (84.9 cm)

39-7/16” (100.2 cm)

45-7/16” (115.4 cm)

51-7/16” (130.7 cm)

57-7/16” (145.9 cm)

63-7/16” (161.1 cm)

B (Hood Depth)

21-7/16” (54.5 cm)

21-7/16” (54.5 cm)

21-7/16” (54.5 cm)

21-7/16” (54.5 cm)

21-7/16” (54.5 cm)

21-7/16” (54.5 cm)

21-7/16” (54.5 cm)

VBCV Wall Custom Ventilator System

Description 30” 36” 42” 48” 54” 60” 66”

Number of lights

Number of filters

Heat lamps

Interior ventilator kits

Exterior ventilator kits

In-line ventilator kits

Interior duct size

Exterior duct size

Interior—Maximum amps

Exterior—Maximum amps

2

2

2

2

2

2

3

3

3

3

4

4

4

4

1 1 1 2 2 2 2

VINV300/

600/1200*

VINV300/

600/1200*

VINV600/

1200*

VINV1200* VINV1200* VINV1200* VINV1200*

DEV900/

1200*

DEV900/

1200*

DEV900/

1200*

DEV1200*/

1500**

DIL900/1200 DIL900/1200 DIL900/1200 DIL1200

DEV1200*/

1500**

DIL1200

DEV1200*/

1500**

DIL1200

DEV1200*/

1500**

DIL1200

7”/10”

(17.8/25.4 cm)

7”/10”

(17.8/25.4 cm)

7”/10”

(17.8/25.4 cm)

10”

(25.4 cm)

10” (25.4 cm)

10”

(25.4 cm)

10”

(25.4 cm)

10”

(25.4 cm)

5.9/9.0

8.7/6.0

5.9/9.0

8.7/6.0

5.9/9.0

8.7/6.0

11.5

8.5/9.2

11.5

8.5/9.2

11.9

8.9/9.2

11.9

8.9/9.2

In-Line—Maximum amps 6.0/7.9

6.0/7.9

6.0/7.9

10.3

10.3

10.7

10.7

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.

Max duct run is 50 ft.

** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.

NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.

26

Installing Hood Canopy

(Custom Hood Canopy Cutouts )

Custom Hood

Canopy

1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right.

2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided.

27

Built-In Ventilator

System

3) OPTIONAL

Rear mounting holes fasten ventilator system to rear of custom hood canopy.

Clearance Dimensions

(VBCV Wall Custom Ventilator System)

Built-In Wall Custom Ventilator

System Dimensions

(VBCV Models )

For 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation

For 300, 600 or 1200 CFM Interior

Ventilator Installation

900 or 1200 CFM Exterior or In-Line Ventilator Installation

30”, 36”, 42” W. Models

30” W.

36” W.

42” W.

C

28-1/4” (71.8 cm)

34-1/4” (87.0 cm)

40-1/4” (102.2 cm)

30” W.

36” W.

42” W.

300 or 600 CFM Interior

Ventilator Installation

30”, 36”, 42” W. Models

D

14-1/8” (35.9 cm)

17-1/8” (43.5 cm)

20-1/8” (51.1 cm)

29 28

Built-In Wall Custom Ventilator

System Dimensions

(VBCV Models )

1200 or 1500 CFM Exterior or In-Line Ventilator Installation

48”, 54”, 60”, 66” W. Models

1200 CFM Interior Ventilator Installation

30”, 36”, 42”, 48”, 54”, 60”, 66” W. Models

30” W.

36” W.

42” W.

48” W.

54” W.

60” W.

66” W.

C

28-1/4” (71.8 cm)

34-1/4” (87.0 cm)

40-1/4” (102.2 cm)

46-1/4” (117.5 cm)

52-1/4” (132.7 cm)

58-1/4” (148.0 cm)

64-1/4” (163.2 cm)

30” W.

36” W.

42” W.

48” W.

54” W.

60” W.

66” W.

D

14-1/8” (35.9 cm)

17-1/8” (43.5 cm)

20-1/8” (51.1 cm)

23-1/8” (58.7 cm)

26-1/8” (66.4 cm)

29-1/8” (74.0 cm)

32-1/8” (81.6 cm)

30

Planning Information

Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product.

• All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.

• Straight runs and gradual turns are best; for example, each 90º elbow is equivalent to 5-10 feet (1.52-3.05 cm) of straight run.

• Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.

• Proper performance is dependent on proper ducting; make sure that a qualified and trained installer is used.

• Check with a qualified and trained installer or local codes for makeup air requirement, if any.

• Max. amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired direct with 2-wire with ground.

Plan where the duct work will be located. Install proper-sized duct work, and roof or wall cap for the type of blower you are using. Recommended hood locations for the most common installations are shown. Adjust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops.

Check Framing

NOTE: Because of the weight of the hood make sure that the mounting screws are driven into the framing and not just the drywall. It may be necessary to drill additional holes in the canopy for proper alignment.

31

Installation

(VWH 10”H. Wall Hoods w/Standard Ventilator) necessary.

W A R N I N G

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Text goe here.

and secure using wiring restrain. Refer to local codes.

32

CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary.

CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary.

Connect black to black, white to white, and the green/bare wire under the green screw.

NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit.

Replace electrical box cover. Make connection to breaker box.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.

33

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Duct Cover Option

(VWH 10”H. Wall Hoods w/Standard Ventilator)

Measure distance from ceiling to canopy.

Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided.

Installation

(VWH 10”H. Wall Hoods w/Recirculating Kit)

Remove damper and discard with transition.

34

Turn recirculating unit upside down. Place vent hood upside down on recirculating unit.

Attach with screws and lock washers provided.

Remove electrical box cover.

Attach with screws.

W A R N I N G

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Flip hood over. Insert 6” of electrical wiring through the top of vent hood and secure. Refer to local codes.

35

CAUTION: Secure vent hood. Make sure mounting screws are secured into framing. Use additional mounting screws and wall anchors, if necessary.

Connect black to black, white to white, and the green/bare wire under the green screw.

NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit.

Replace electrical box cover. Make connection to breaker box.

Assemble brackets to baffles and insert charcoal filters.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Installation

(VWH 18”H. Wall & VCWH Chimney Wall Hoods)

Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (provided locally) to wall using screws provided.

Use additional mounting screws to secure hood to wood strip.

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

36

CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary.

CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing use additional mounting screws, if necessary.

37

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Duct Cover Option

(VWH 18”H. Wall Hoods)

Measure distance from ceiling to canopy.

Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided.

Duct Cover Option

(VCWH Chimney Wall Hoods)

Measure distance from ceiling to canopy.

Tape to avoid scratching.

Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place and remove tape.

Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided.

38 39

Installation

(VCIH Island Hoods)

Check framing where cutout will be.

NOTE: 200 lb. limit.

Cut appropriate size hole in ceiling. Either 7” or 10” depending on your specific unit and ventillator kit.

Attach duct cover to optional ceiling mounting bracket.

Run duct work down to bottom edge of duct cover/soffit and secure in place. Make sure the duct does not stick down past the cover.

Attach canopy to duct cover/soffit. Seal top of hood to duct with aluminum tape.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Attach duct cover to ceiling. The ceiling bracket can be hidden by using a locally supplied trim.

Additional support option. Drill holes in all four corners for threaded rod and run rods from hood to ceiling.

40

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. NOTE: Number of spacers and baffles may vary by model.

41

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Installation

(DCWH Classic Chimney Wall Hoods)

Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (not included) to wall using screws provided.

Use additional mounting screws to secure hood to wood strip.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

CAUTION: Secure vent hood to wall using screws provided.

Make sure mounting screws are secured into frame. Use additional mounting screws and wall anchors, if necessary.

CAUTION: If not using a duct cover, using screws provided make sure top mounting screws are secured into soffit or cabinet frame. Use additional mounting screws, if necessary.

42

Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip.

Slide filter front over front lip. Push filter rear up, then slide back over rear lip.

Duct Cover Option

(DCWH Classic Chimney Wall Hoods)

Measure distance from ceiling to canopy.

43

Tape to avoid scratching.

Service & Registration

Service & Parts

Only authorized replacement parts may be used in performing service on the appliance.

Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician.

Record the following information indicated below. You will need it if service is ever required.

The serial number and model number for your appliance are located on the identification plate mounted on the inside of the hood canopy.

Model number

_________________________________________

Serial number

_________________________________________

Date of purchase

_________________________________________

Date installed

_________________________________________

Dealer's name

_________________________________________

Address

_________________________________________

44

Wiring Diagram

PROFESSIONAL BUILT-IN HOODS

45