Owner’s Manual

6052241/B

Fire Rated

Bonaire Ducted Evaporative Air Conditioning

Fire Rated EAC

Introduction

This product has been provided with a butterfly closer (Enviroseal) to comply with The Australian

Standards AS3959-2009 Construction of Buildings in bushfire prone areas. Additionally ember protection consisting of stainless steel mesh is provided as a cover over the filters of the unit.

These product enhancements enable the product to comply with the requirements of

AS3959 - 2009:

BAL - 12.5

BAL - 19

BAL – 29

Achieving the fire rating BAL Codes listed above requires the Enviroseal to be fitted in accordance with its installation instructions (provided with the Enviroseal).

Note that BAL – 40 and BAL – FZ do not permit the installation of roof mounted evaporative air conditioners.

The enhanced unit for BAL – 12.5, BAL – 19 & BAL – 29 is identified with a sticker as shown below.

To account for the losses in air flow with the butterfly closer (Enviroseal) and the ember screen fitted, consideration should be given in the system design and unit size selection to accommodate losses. Air flow losses could be as high as 20% depending on the system design.

6052241/B

Fire Rated EAC

Maintenance Requirements

As the aperture size of the mesh hole is very small, there is the potential for frequent maintenance to the ember screen to maintain maximum air flow.

The fitting of the ember screen along with the Enviroseal does give the unit a slight reduction in air flow. If there is blocking of the ember protector, there will be a noticeable decrease in the availability of air indicating the requirement to service the ember screen / filters.

Subject to environmental conditions, ember screen / filter maintenance could be required at least monthly during the operational period.

There are 2 levels of service that can be used:

1

2

Using a garden hose, pressure wash out any excess debris to clear the aperture holes.

Completely remove the ember protector from the louvers panel assembly and clean.

Text and Illustration Copyright Climate Technologies 2010

All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording or by any information storage and retrieval system, without prior permission in writing from Climate Technologies

In the interest of continued product improvement Climate Technologies reserves the right to alter specifications without notice. E.&O.E.

6052241/B

Manufactured by

Climate Technologies

ABN 13 001 418 042

26 Nylex Avenue

Salisbury, SA 5108

Australia www.climatetechnologies.com.au

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Complies with AS3959 - 2009 for BAL - 12.5, BAL - 19, and BAL - 29 fire ratings
  • Butterfly closer (Enviroseal) for enhanced fire protection
  • Stainless steel mesh ember protection for added safety
  • High airflow for efficient cooling
  • Designed for use in bushfire-prone areas

Related manuals

Frequently Answers and Questions

What are the fire ratings that the BONAIRE Fire Rated 2010 meets?
BAL - 12.5, BAL - 19, and BAL - 29
What is the purpose of the butterfly closer (Enviroseal) and ember protection?
To enhance fire protection by preventing embers and flames from entering the unit
Is the airflow of the BONAIRE Fire Rated 2010 affected by the safety features?
There is a slight reduction in airflow due to the ember screen, but it maintains a high level of airflow for efficient cooling
How often should the ember screen and filters be cleaned?
Monthly during the operational period, or more frequently if there is significant debris accumulation