Emerson CARRERA VERANDA CF542ORB00 is a wet location ceiling fan suitable for outdoor areas like porches, patios, and decks. It features a white finish and comes with five reversible blades, allowing you to customize the airflow direction for your comfort. The fan has a powerful motor that provides efficient air circulation and a quiet operation. It also includes a built-in light kit for added illumination.
advertisement
READ AND SAVE THESE INSTRUCTIONS
CARRERA VERANDA
™
42” Ceiling Fan
Wet Location Owner's Manual
Model Numbers
CF542AW00
Summer White
CF542ORB00
Oil Rubbed Bronze
Net Weight:
17.6
Lbs.
Part No. F40BP74030000 Form No. BP7403
U.L. Model No.: CF542
!
WARNING
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999” and
Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
NOTE: This product is suitable for use in wet locations when installed in a GFCI protection branch circuit.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label.
You should record this data above and keep it in a safe place for future use.
2 U.L. Model No.: CF542
THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS.
USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS.
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver
One wire stripper
Three wire connectors (supplied)
One stepladder
Installed Wire Length
Up to 50 ft.
50-100 ft.
Wire Size A.W.G.
14
12
MATERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:
!
WARNING
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 8). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
!
WARNING
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
!
WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
1.
Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. Fan motor assembly b. One switch housing assembly c. One ceiling cover d. Five blade flanges e. One hanger ball/4.5” downrod assembly f. One hanger bracket g. One coupling cover h. Five fan blades i. One bracket switch housing assembly j. One loose parts bag containing:
1. Sixteen M5 x 6mm washer head blade screws
2. One M4 x 12mm flat head screw
3. One M6 x 14mm pan head screw with lockwasher
4. One M4 x 10mm serrated pan head screw
5. One die-cast pendant
6. One pendant coupler
3
7. Three wire connectors
8. Two threaded studs
9. Two knurled knobs
10. Two lockwashers
11. One clevis pin
12. One hairpin clip
13. One balance kit
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost.
If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2.
Remove the fan assembly from the protective plastic bag. Place the fan assembly into the upper foam pad with the bottom of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
FAN BLADES BRACKET SWITCH
HOUSING ASSEMBLY
LOOSE PARTS
BAG
BLADE
FLANGES
CEILING
COVER
COUPLING
COVER
FAN MOTOR
ASSEMBLY
SWITCH HOUSING
ASSEMBLY
HANGER BALL/
DOWNROD ASSEMBLY
HANGER
BRACKET
U.L. Model No.: CF542
Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
!
WARNING
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked
“Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
!
WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before attempting installation. All wiring must be in accordance with
National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!
WARNING
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
How to Put Your Ceiling Fan Together
1.
One by one unscrew each screw and discard screw and shipping retainer (Figure 1).
M5 x 6mm WASHER
HEAD BLADE SCREW
(3 per blade/flange)
FAN BLADE
ADAPTER
PLATE
REMOVE AND DISCARD
THE FIVE SHIPPING
RETAINERS AND SCREWS
FROM THE ADAPTOR
PLATE
Figure 1
2.
Mount blade flanges to fan blades using three M5 x
6mm washer head blade screws (Figure 2).
NOTE: Take care not to scratch fan housing when installing blades.
BLADE FLANGE
Figure 2
3.
Loosely attach one blade/flange assembly to the motor hub by securing the two M6 x 14mm captive pan head screws. Make sure the screws are NOT tightened (Figure 3). Repeat this procedure for other four blade assemblies.
!
WARNING
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
4
U.L. Model No.: CF542
4.
The blade flanges have an interlocking feature that must be fully engaged before tightening the screw.
Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again.
REMOVE ONE M4 x 10mm
SERRATED PAN HEAD
SCREW AND LOOSEN THE
OTHER TWO SCREWS
ADAPTER PLATE
BLADE/FLANGE
ASSEMBLY
9.
Remove the three mounting screws from the bracket switch housing assembly (Figure 5).
SWITCH HOUSING
ASSEMBLY
M6 x 14mm CAPTIVE PAN
HEAD SCREW (2 per blade/flange assembly)
SWITCH HOUSING
CONNECTOR
MOTOR CONNECTOR
Figure 3
5.
Remove and retain one of the three M4 x 10 mm serrated pan head screws from the adapter plate
(Figure 3). Loosen the other two serrated head screws, three or four turns.
6.
Position the bracket switch housing assembly on the adapter plate so that the two screws mate with the two keyhole slots in the bracket switch housing assembly with rubber cover.
7.
Turn the bracket switch housing assembly clockwise and tighten both screws (Figure 4).
Reinstall the other serrated head screw in the remaining hole in the bracket switch housing assembly.
REINSTALL ONE M4 x 10mm SERRATED
PAN HEAD SCREW
ROTATE SWITCH HOUSING ADAPTER
CLOCKWISE TO ENGAGE TWO KEYHOLE
SCREWS
TIGHTEN TWO
M4 x 10mm
SERRATED PAN
HEAD SCREWS
Figure 5
SWITCH HOUSING
10.
Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three M4 x 12mm flat head screws
(supplied) (Figure 6).
!
WARNING
To avoid possible fire or shock, do not pinch wires between the switch housing assembly and the bracket switch housing assembly.
SWITCH HOUSING
ASSEMBLY
Figure 4
8.
Engage the connector of the switch housing assembly with the motor connector (Figure 5). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly.
M4 x 12mm FLAT HEAD
SCREW (3)
Figure 6
11.
Carefully turn partially assembled fan upside down and place in styrofoam form carton, in preparation for final installation.
5
U.L. Model No.: CF542
12.
Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 7). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 15.
PIN
HANGER
BALL
14.
Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly
(Figure 9).
DOWNROD
SETSCREW
Figure 7
13.
Separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Remove the upper setscrew from the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling.
Install the clevis pin and secure with the hairpin clip (Figure 8). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed. Reinstall the upper setscrew in the motor coupling. Check that the lower setscrew is tightened securely
(Figure 8).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
!
WARNING
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
Figure 9
15.
Reinstall the hanger ball (Figure 10) on the downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
!
DOWNROD
WARNING
CEILING
COVER
COUPLING COVER
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
PIN
HANGER BALL
CEILING
COVER
SETSCREW
Figure 8
CEILING
COVER
DOWNROD
COUPLING COVER
Figure 10
6
16.
The fan comes with blue, black and white leads that are 80” long. Before installing fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
17.
You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.
U.L. Model No.: CF542
How to Hang Your Ceiling Fan
!
WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 11).
2.
Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 12).
CEILING
AT LEAST
7'
!
WARNING
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
FLOOR
Figure 11 !
WARNING
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
!
WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support”.
!
WARNING
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
!
WARNING
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for
Fan Support”, and use screws supplied with outlet box.
Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.
OUTLET
BOX
1.
Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box.
(Figure 12.)
NOTE: CEILING COVER
OMITTED FOR CLARITY.
OUTLET
BOX
Figure 13
HANGER
BRACKET
HANGER BALL/
DOWNROD ASSEMBLY
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
Figure 12
Figure 2
TAB
HANGER
BRACKET
7 U.L. Model No.: CF542
How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
!
WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
!
WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before attempting installation.
NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.
1.
Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied.
BLACK AND BLUE
FAN WIRES
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
WHITE SUPPLY
(NEUTRAL)
3.
Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.
4.
Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 15).
5.
Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 15).
Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.
CEILING
COVER
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
WHITE FAN
WIRE
BLACK SUPPLY
(HOT)
NOTE: CEILING COVER
Figure 14 OMITTED FOR CLARITY.
Figure 4
NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring.
2.
Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 14). Securely connect the fan motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
14). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the green equipment-grounding conductor and white grounded neutral conductor on one side of the outlet box and the black and blue ungrounded conductors on the other side of the outlet box.
THREADED
STUDS (2)
KNURLED
KNOBS (2)
Figure 15
LOCKWASHERS
(2)
!
WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
6.
Cut the 3-speed switch pull chain to a desired length (optional). Connect the die-cast pendant
(supplied) to the 3-speed switch pull chain by sliding the die-cast pendant (small hole first) onto the pull chain. Attach the chain coupling to the end of the chain and allow the die-cast pendant to fall down over the coupling.
8 U.L. Model No.: CF542
Using Your Ceiling Fan
1.
Restore electrical power to the outlet box by turning the electricity on at the main fuse box.
2.
Check the operation of the fan by gently pulling on the pull chain switch.
3.
All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. If airflow is desired in opposite direction, turn your fan OFF and wait for the blades to stop turning, then slide the reversing switch to the “up” position, and turn fan on again.
4.
The fan blades will turn in the opposite direction and reverse the airflow.
Your fan model is equipped with a 4-position,
3-speed pull chain switch. The operating sequence is as follows:
Three-Speed
1st Pull—HIGH
2nd Pull—Medium
3rd Pull—Low
4th Pull—OFF
Season
Summer
Winter
REVERSIBLE
SWITCH
SPEED
CONTROL
SWITCH
Reverse Switch Information
Rotation Direction Switch Position
Counter-Clockwise
Clockwise
Down
Up
Maintenance
IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
!
WARNING
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
Accessories
1.
Ceiling Fan Light Kits (see store or catalog).
2.
Ceiling Fan/Light Controls (see store or catalog).
3.
Downrod Extension Kits (see store or catalog).
4.
Ceiling Fan Blades (see store or catalog).
!
WARNING
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
!
WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
9 U.L. Model No.: CF542
Energy Efficient Use of Ceiling Fans
Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan. Here are a few tips to ensure quality and product performance.
Choosing the Appropriate Mounting Location. Ceiling fans should be installed, or mounted, in the middle of the room and at least 7 feet above the floor and 18 inches from the walls. If ceiling height allows, install the fan 8 - 9 feet above the floor for optimal airflow. Consult your Emerson
Retailer for optional mounting accessories.
Using the Ceiling Fan Year Round.
In the summer, use the ceiling fan in the counter-clockwise direction. The airflow produced by the ceiling fan creates a wind-chill effect, making you "feel" cooler. Select a fan speed that provides a comfortable breeze, lower speeds consume less energy. In the winter, reverse the motor and operate the ceiling fan at low speed in the clockwise direction. This produces a gentle updraft, which forces warm air near the ceiling down into the occupied space. Remember to adjust your thermostat when using your ceiling fan - additional energy and dollar savings could be realized with this simple step!
Turn Off When Not in the Room. Ceiling fans cool people, not rooms. If the room is unoccupied, turn off the ceiling fan to save energy.
!
WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.
Trouble Shooting
TROUBLE
1. Fan will not start.
3. Screws securing fan blade flanges to motor hub are loose.
4. Wire connectors inside switch housing rattling.
PROBABLE CAUSE
2. Fan sounds noisy.
1. Blades not attached to fan.
2. Loose screws in motor housing.
SUGGESTED REMEDY
1. Fuse or circuit breaker blown.
1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan, 2. Check line wire connections to fan and switch or loose switch wire connections in the switch housing.
!
wire connections in the switch housing.
WARNING: Make sure main power is
3. Reversing switch in neutral position.
turned OFF.
3. Make sure reversing switch position is all the way to one side.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing are snug (not over-tight).
3. Check to make sure the screws which attach the fan flanges to the motor hub are tight.
4. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing.
!
WARNING: Make sure main power is turned OFF.
5. Tighten screws securely.
3. Fan wobbles excessively.
5. Screws holding blades to flanges are loose.
1. Setscrew in motor coupling is loose.
2. Setscrew in hanger ball/downrod assembly is loose.
3. Screws securing fan blade flanges to motor are loose.
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet box is not securely fastened.
6. Fan blades out of balance.
1. Tighten both setscrews securely in the motor coupling.
2. Tighten the setscrew in the hanger ball/ downrod assembly.
3. Check to be sure screws which attach the fan blade flanges to the motor are tight.
4. Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor.
If flanges are seated incorrectly, loosen the flange screws and retighten according to the procedure in the section on "How to Put
Your Ceiling Fan Together".
5. Tighten the hanger bracket screws to the outlet box, and/or secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can redistribute the weight and result in smoother operation.
10 U.L. Model No.: CF542
Repair Parts Listing
Model Numbers
17
18
19
20
21
22
23
13
14
15
16
9
10
11
12
5
6
*
4
7
8
1
2
3
Key
No.
Description
* Hanger Ball Assembly,
Consisting of:
Hanger Bracket
Hanger Ball
Downrod (4.5”)
—
Parts Bag Containing:
Wire Connector (3)
Pin, Clevis
Clip, Hairpin
Screw, Flat Head M4 x 12mm (1)
Screw, Pan Head M6 x 14mm, with Lockwasher (1)
Screw, Washer Head M5 x 6mm (16)
Screw, Serrated Pan Hd M4 x 10mm (1)
Die-cast Pendant
Threaded Stud (2)
Lockwasher (2)
Knurled Knob (2)
Coupler, Pendant
Balancing Kit (1)
Canopy, Ceiling (1)
Wiring Harness (1)
Switch Housing (1)
Coupling Cover (1)
Flange (set of 5)
Blade (set of 5)
Switch Housing Adapter
Cover Assembly
Owner's Manual
CF542AW00
761655-21
—
—
—
763913-3
—
—
—
—
—
—
—
—
—
—
—
—
—
763921-AW
763981-5
763919-AW
763922-AW
763930-AW
763932-AW
763915-AW
BP7403
CF542ORB00
761655-32
—
—
—
763913-3
—
—
—
—
—
—
—
—
—
—
—
—
763921-ORB
763981-3
763919-ORB
763922-ORB
763930-ORB
763932-ORB
763915-ORB
BP7403
16
4
1
12
5
13
14
2
3
20
17
6
Before discarding packaging material, be certain all parts have been removed.
HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:
• PART NUMBER
• NAME OF ITEM
• PART DESCRIPTION
• MODEL NUMBER
For repair parts, phone 1-800-654-3545.
22
9
21
8
7
23
10
18
19
11
15
11 U.L. Model No.: CF542
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND
ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR
REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR REMOVAL, REINSTALLATION
AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR
RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort
Products, Division of Emerson Electric Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson
Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND
EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES.
Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Part No. F40BP74030000
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant • St. Louis, MO 63136
Printed in China 10/09 Form No. BP7403
U.L. Model No.: CF542