9.5kW White - Installation Guide

Add to my manuals
32 Pages

advertisement

9.5kW White - Installation Guide | Manualzz
Vitalise
®
Installation guide
S, SL & SLX
Contents
Important information
- Safety information
- Pipework connections
- Isolating valves
- Siting
- Pressures
- Pressure relief device
4
4
4
4
4
5
5
Components
6
Pipework installation
7
Electrical installation
8
- Mains voltage connection
- Electrical rating
- Wiring installation
- Earth bonding
9
10
11
12
Showerhead installation
12
Front cover installation and shower commissioning
14
Thermal trip
15
Electronic cut out
15
User guide
16
Cleaning and maintenance
16
Cleaning the filter
16
Trouble shooting guide
17
Approvals
31
3
Important information
THIS INSTALLATION AND USER GUIDE IS DESIGNED TO ENSURE THE SAFETY OF THE INSTALLER AND USER AND THE
OPERATION/RELIABILITY OF THE PRODUCT. FAILURE TO OBSERVE THESE MAY CAUSE A HAZARD, DAMAGE THE PRODUCT AND
INVALIDATE YOUR GUARANTEE.
Safety information
This product must be installed by a competent person in accordance with all relevant current water supply regulations.
The electrical installation should be carried out by a qualified person in accordance with IEE (Institute of Electrical Engineers) wiring
regulations (BS 7671) and certified to current building regulations. With reference to building regulation Part P, any new installation or
replacement product installation which is not identical to the product being replaced, the cable sizes, circuit protection devices, earth
bonding and all other requirements of the building regulation must be assessed by a (registered) qualified electrician and installed to
the site conditions (see table in electrical rating).
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR
MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN INITIAL SUPERVISION OR
INSTRUCTION CONCERNING THE USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN SHOULD BE
SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.
THIS PRODUCT IS SUITABLE FOR DOMESTIC USE ONLY
Pipework connections
This shower unit is designed for use with 15mm British Standard pipe and must be fitted with a copper olive. This product is suitable
for top, bottom or rear entry pipe work and cable connections. Supply lines should be flushed clear of any debris prior to installation of
the unit.
Plastic pipe may be used (with appropriate inserts) if certified by the plastic pipe manufacturer for use with compression fittings.
The copper olive provided must be used.
WARNING: PLASTIC PIPE INSERTS CAN BE VERY RESTRICTIVE. WHERE USED THE PRESSURE / FLOW REQUIREMENTS DETAILED IN
THE PRESSURES SECTION OVERLEAF MUST BE MET.
Pipe runs in the loft or behind radiators should be avoided.
Isolating valves
A suitable full bore isolation valve must be fitted to the incoming supply in accordance with the current water supply regulations and
our terms of warranty. The isolation valve must be sited in an accessible location for service and maintenance purposes.
Siting
The unit must be mounted on a flat, vertical finished wall with the hose pointing downwards. Any distortion of the back plate may
result in the unit not working.
DO NOT tile up to or use sealants around the unit. The shower is spaced off the wall by integral pillars to allow air circulation around
the unit.
The casing must not be sited where it is subject to continuous spray from the shower head.
The Vitalise SLX variant unit should be sited in a position where the LCD display is easily visible by the users.
The unit must not be sited where it is likely to freeze.
The rail system must be sited in a position where the hose when connected to the shower unit is not stretched or kinked.
WARNING: DO NOT SWITCH THE SHOWER ON IF THERE IS A POSSIBILITY THAT THE SHOWER COULD BE FROZEN. IF YOU HAVE
SWITCHED THE SHOWER ON, SWITCH OFF IMMEDIATELY (Please refer to the troubleshooting guide page 17).
4
Pressures
Check that the supplied dynamic (running) water pressure to the electric shower is adequate.
The required supplied dynamic (running) pressure is:Maximum 1.0MPa (10 Bar)
Minimum 0.07MPa (0.7 Bar) at a flow rate of 8 litres per minute.
Where pressures are likely to exceed 1.0MPa (10 bar), a pressure reducing valve must be fitted to the incoming mains supply. A setting
of 0.3MPa (3 bar) is recommended. It should be noted that daytime pressures approaching 8 bar can rise above the stated maximum.
The use of other services connected to the same water supply as the shower unit may cause the water pressure to drop below the
minimum required. This should therefore be taken into consideration.The minimum pressure/flow rate provided by your water supplier
may be below the requirements of this product. Contact your water provider for more details. Note: The running pressure at your
shower can be lower than this due to pressure losses in the internal pipe work in your home.
Note: Models of electric showers can differ in performance; if your previous electric shower had a lower output flow rate, then
this may have produced a higher dynamic pressure at the shower head.
Flushing
Some modern fluxes can be extremely corrosive and, if left in contact, will attack the working parts of this unit. All soldering must be
completed and the pipe work thoroughly flushed out in accordance with current Water Supply Regulations prior to connection of the
product.
Pressure relief device (PRD)
To meet European standards, the shower unit features an integral pressure relief device (PRD). The PRD provides a degree of shower
unit protection should an excessive build up of pressure occur within the shower.
DO NOT operate the shower with a damaged or kinked hose or blocked shower head, as this can cause excessive water temperature
and/or the PRD to operate. Failure to follow this instruction will invalidate the product guarantee.
The outlet must not be connected to any tap or fitting, including water saving handsets and flow restrictors, other than those
specified as the shower will only function correctly with the hose and handset provided (see showerhead installation instructions
from page 12). The use of alternative shower heads and/or hoses can cause excessive, potentially scalding, water temperature and/or
the PRD to operate and will invalidate the product guarantee.
Please fully commission the shower prior to use following the instructions on page 14. Failure to do this could cause the PRD to
operate and will invalidate the guarantee.
The shower must be sited over a bath or shower tray as in the event of the PRD operating water will drain from the bottom of the
shower unit.
5
Components
Vitalise S
(White/chrome variant not shown)
Vitalise SL
6
Vitalise SLX
Pipework Installation instructions
!
In addition to the guide that follows it is essential that the written instructions on pages 4 and 5 are read and understood, and
that you have all the necessary components before commencing installation. Failure to install the product in accordance with
these instructions may adversely affect the warranty terms and conditions. Do not undertake any part of this installation
unless you are qualified to do so. Prior to starting, ensure you are familiar with the necessary plumbing and electrical
regulations and legislation required to install the product correctly and safely.
Aqualisa Products Ltd reserves the right to revoke the terms of the warranty should access to the service connections be denied
by the use of solid setting infill material.
1
Remove the warning label and outlet bung from the unit.
2
Set the temperature dial to the full cold position to ensure correct alignment during reassembly.
!
Ensure the internal flow/temperature control mechanism is not moved during assembly once the cover has been removed.
3
Remove the fixing screws and lift the casing up and away from the
engine assembly. Carefully detach the connector and pull the casing
clear.
4
Tape the template provided onto the finished wall surface in the desired position and mark the three fixing points. Drill
and prepare the fixing holes using the fixings provided if suitable.
5
Remove the service tunnel and set aside.
6
If using top or bottom entry pipe work connection, fix the unit to the wall using the screws provided, if suitable.
7
Flush through the water supply pipe allowing it to discharge safely to waste.
!
8
Some modern fluxes can be extremely corrosive and, if left in contact will attack the working parts of this unit. All soldering
must be completed and pipe work thoroughly flushed out in accordance with current Water Supply Regulations prior to
connection of the product
Remove the inlet and outlet blanking caps and rotate the inlet elbow connector for either top,
bottom or rear entry.
7
9
Pipe work connection must be made using a 15mm compression nut (not supplied). A copper olive
is supplied and must be fitted onto the pipe prior to the nut being connected to the brass inlet
connector.
!
This product is suitable for use with plastic pipe provided the manufacturer has certified
suitability for use with compression fittings. The plastic pipe inserts MUST be fitted, however, as
these can be very restrictive, they MUST meet the pressure/flow requirements of the product.
!
!
This product is not suitable for stainless steel pipe.
If using rear entry pipework, for ease of installation and maintenance, pipework connection
using an elbow is recommended as shown.
10
For rear fed installations, fit the unit to the wall using the fixings provided, if suitable.
11
Turn on the water supply to the shower unit and check for leaks up stream of the shower unit. If all is sound turn off the
water supply to the shower unit.
!
If required, ensure the water pressure to the shower unit is within the minimum and maximum requirements by following
the pressure testing procedure on page 17.
Electrical installation
!
BEFORE ANY ELECTRICAL CONNECTION IS ATTEMPTED, THE ELECTRICITY SUPPLY MUST BE TURNED OFF AT THE MAINS
SWITCH. FAILURE TO DO SO COULD RESULT IN ELECTROCUTION.
The electrical installation should be carried out by a qualified person in accordance with IEE (Institute of Electrical
Engineers) wiring regulations (BS7671).
THIS APPLIANCE MUST BE EARTHED.
IN THE INTERESTS OF ELECTRICAL SAFETY, A 30mA RESIDUAL CURRENT DEVICE (RCD) MUST BE INSTALLED IN ALL UK
230-240V ELECTRIC SHOWERS. THIS MAY BE PART OF A CONSUMER UNIT OR A SEPARATE UNIT.
A suitable double-pole isolating switch for supply disconnections must be incorporated in the fixed wiring circuit in
accordance with current wiring rules. This must have a mechanical indicator showing when the switch is in the OFF position.
A neon lamp alone is not sufficient. (see the typical sysytem diagram in the MAINS VOLTAGE CONNECTION section
overleaf). If it is fitted in the bathroom it must be a cord operated type. The switch must be readily accessible and clearly
identifiable in zone 3 i.e. at 0.6m horizontally from the shower cubicle or edge of bath, or located above zone 2 (i.e. adjacent
to the shower cubicle or edge of bath, but at least 2.25m from the floor) as detailed below. This requirement does not apply
to the pull cord from the switch. See illustration overleaf.
Where shower cubicles are located in rooms other than bathrooms, any socket outlet in the room must be situated at least
3m from the shower cubicle and protected by a 30mA RCD.
8
Switch must
be outside
Zone 2
Switch must
be outside
Zone 2
2.25m
2.25m
0.6m
0.6m
0.6m
!
0.6m
YOUR ATTENTION IS ALSO DRAWN TO THE SAFETY INFORMATION DETAILED WITHIN THE IMPORTANT INFORMATION
SECTION AND THE ELECTRICAL RATING SECTION. Page 10.
Mains voltage connection
!
Please refer to the typical system diagram shown below.
The following notes are for guidance only – the installation must comply with current regulations
Please ensure you have read and understood the Electrical installation section on page 8 prior to completing any electrical
connections.
RCD (can be part of consumer unit)
Recommended
80A or 100A
mains switch
Double pole isolating
switch - pull cord
or wall mounted in
accordance with
BS7671
Shower unit
9
!
BEFORE ANY ELECTRICAL CONNECTION IS ATTEMPTED, THE ELECTRICITY SUPPLY MUST BE TURNED OFF AT THE
MAINS SWITCH. FAILURE TO DO SO COULD RESULT IN ELECTROCUTION.
1
The shower unit must only be fitted to a 230-240V ac supply.
2
The shower unit must be connected to its own independent electrical circuit. It MUST NOT be connected to a ring main,
spur, socket outlet or lighting circuit, otherwise the circuit will overheat.
3
Check that the consumer unit (main fuse box):
a) Has a main switch rating of 80A or above and
b) Has a spare fuse way which will take the fuse/mcb (miniature circuit breaker) that you need to fit.
If so you can wire the shower direct to the consumer unit (please refer to the typical system diagram overleaf).
(Not all consumer units accept a 35/40/45A sized fuse).
!
If the consumer unit has a rating below 80A or if there is no spare fuse way, then the installation will not be straightforward.
It may be necessary to install a new consumer unit to service the whole house or just the shower. A qualified person should
install this. It may be necessary to contact the electricity supplier to upgrade the incoming supply.
Electrical rating
!
Refer to the electrical rating diagram (shown below) to determine the nominal current of the shower. The current rating of
the supply cable must be at least that of the shower itself. Use the chart to choose a fuse or mcb with a rating of less than
that of your chosen cable.
Shower rating @ 240V
8.5kW
9.5kW
10.5kW
Nominal current @ 240V
35.4A
39.6A
43.8A
40A
40A
45/50A
40/45A
45A
MCB rating
40/45A
Cartridge fuse
Min cable Max cable
size mm2 run in m
Installed in
insulated wall
Type
of
cable Conduit or trunking
run
Clipped direct
or buried in
uninsulated wall
10
Min cable Max cable Min cable
size mm2 run in m size mm2
Max cable
run in m
10
61
10
55
10
50
6
37
10
55
10
50
6
37
6
33
10
50
If upgrading to a higher kW shower it is essential to ensure that the electrical circuit, including the wiring and isolating switches
are adequate for the increased load.
Notes:1. Cable selection is dependant on de-rating factors detailed in the notes below.
2. In certain installations the combination of low voltage and extended cable lengths may result in loss of power and a
consequential reduction in flow rates.
3. Above cable sizes are the minimum acceptable sizes. Sizes greater than these shown above may be used and should be used if
cable runs are greater than indicated (above cable runs are based on a maximum 9.6v drop).
4. Rewirable fuses are not recommended and are not covered by this table.
5. Installation should be carried out by a qualified person. Please refer to BS7671 (Wiring regulations) if in doubt.
6. A 16mm² cable may be required for long cable runs.
Cables which are chased into the wall must be protected by the use of a conduit or sheathing. Surface mounted cables must also
be protected by a suitable approved conduit.
The current rating will be reduced if the cable is:
a. Bunched with others.
b. In an ambient temperature above 40oC.
c. In an insulated wall or within thermal insulation, e.g. loft insulation.
d. In any other unusual position.
If in doubt about any aspect of electrical insulation, consult a qualified electrical engineer or the electricity supplier.
!
WE STRONGLY RECOMMEND NOT USING REWIRABLE FUSES.
Wiring installation
1
Loosen the terminal screws and insert the wires as indicated on the back plate moulding.
2
Resecure the terminal block screws. Ensure connections are tight and secure to prevent
overheating.
!
Any cable MUST NOT have the outer insulation stripped back beyond the bottom of the backplate
and must be protected from water as shown.
16mm cable can only be used for bottom entry due to the ability to bend the cable.
11
3
If fitting the shower unit with bottom entry connections remove the blanking cap from the service
tunnel.
4
Place the service tunnel onto the shower unit ensuring it fits flush with the shower unit back plate.
Earth bonding
!
The installation must be earth bonded in accordance with current regulations.
Where earth bonding of the premises is not evident, it may be necessary to run a bonding cable back to the earth
terminal at the consumer unit.
Shower head installation
The shower head should be sited close to the shower unit, not necessarily on the same wall, but so that the unit is not subjected to
continuous spray. Ensuring the shower hose is not kinked or under strain, the shower head should be sited so that it is no more than
610mm (2ft) above the bottom of the unit or no lower than 305mm (1ft) below the unit, when in its normal position in the shower
head holder.
!
THE SHOWER OUTLET, HOSE AND HANDSET ACT AS A VENT. THEY MUST NOT BE BLOCKED, OBSTRUCTED OR HAVE
CONNECTED TO THEM ANY FITTING NOT APPROVED BY AQUALISA PRODUCTS LIMITED. THE USE OF UNAPPROVED
ACCESSORIES MAY INVALIDATE THE GUARANTEE AND MAY AFFECT THE PERFORMANCE AND SAFETY OF THE UNIT.
1
Prepare two fixing points 620 – 625mm vertically apart using the fixings provided, if suitable.
2
If fitted, remove the end caps from the rail end bodies and set aside.
12
3
Secure the top rail end body with the rail locating lug to the wall using the fixing provided,
4
Rotate the knob on the handset holder and carefully slide the holder onto the rail, ensuring
if suitable.
that the holder is in the correct orientation, with the widest part of the ratchet mechanism
uppermost.
!
CURRENT WATER SUPPLY REGULATIONS STATE THAT THE HANDSET SHOULD NOT BE ABLE
TO PASS A POINT 25MM ABOVE THE SPILL LEVEL OF THE BATH OR SHOWER TRAY. IF THIS
CAN NOT BE ACHIEVED, THE HOSE RESTRAINT MUST BE FITTED.
5
Attach the bottom rail end body onto the rail. Place the rail assembly into the top rail end
6
Secure the rail assembly to wall using the fixings provided, if suitable, ensuring the rail and rail end bodies remain firmly
7
Place the top rail end cap into the top rail end body ensuring the locking tab is correctly
8
Rotate the bottom rail end cap 90 o so the locking tab avoids the rail and push firmly into position within the bottom rail
body, taking care to engage the location slot in the rail onto the lug in the rail end body.
engaged.
fitted within the rail slot and push firmly into position.
end body.
Please complete the commissioning procedure detailed overleaf prior to connecting the handset and hose.
13
Front cover installation and shower commissioning
!
1
This shower must be fully commissioned following the procedure detailed below before use. Failure to do so could damage
the shower and invalidate the guarantee.
Hold the cover next to the shower unit on the wall and carefully attach the connector
as follows:
Vitalise S
Connect to the flying lead.
Vitalise SL
Connect to the PCB unit.
Vitalise SLX
Connect to the PCB unit.
2
!
Carefully offer the front casing onto the back plate assembly ensuring the wires are not trapped.
Refit the fixing screws and secure the front cover to the backplate.
The control knob, in the fully cold position, may have to be slightly adjusted to enable the
keyways to align.
3
Ensuring the front cover is fitted correctly, secure the cover to the back plate using the fixing screws,
taking care not to overtighten.
4
Without fitting the shower head, fit the hose washer into the hose and attach to the shower outlet
to allow the water to discharge safely to waste.
5
Turn the flow control knob to ensure it moves smoothly. If not, the knob may be fitted incorrectly. The shower should be
commissioned with the knob in the mid position (12 o’clock).
6
If installing Vitalise S model, set the power/heat setting to low.
7
Turn on the electrical isolation switch and press the start stop button.
!
14
The Vitalise SLX LCD screen on the shower unit will display 3 dashes.
8
Select the low power/heat setting. (Refer to the separate user guide booklet).
9
Slowly turn the flow control knob towards the hot direction. The heater elements should now be hotter and the temperature
of the spray should increase.
10
Adjust the flow control knob to provide the desired temperature. Allow a few seconds after each adjustment for the
temperature to stabilise. A cool shower can be achieved with the flow control knob set towards the cold direction.
The temperature achieved will depend on the incoming water temperature, pressure and power setting.
11
Repeat the above procedure with the other power/heat settings.
12
Remove the labels from the front cover of the fitted unit ensuring the model and bar code label located under the unit
remain in place.
Handset to hose assembly
1
Pass the hose through the hose restraint (if required). Ensuring the hose washer is in the
correct position, connect the hose to the handset, taking care not to overtighten and place
into position within the handset holder.
Thermal trip
The Thermal trip cut out will operate with extreme water temperatures. Power to the heater element(s) is cut when the trip operates.
Power restores when the water is cold enough to reset the trip. Unless the temperature dial is adjusted, or other cause of high
temperature is eliminated, the element(s) will continue to cycle on/off and the temperature will cycle hot and cold. Temperature
reduces, but the heat setting knob (Vitalise S) / button indicator (Vitalise SL & SLX) remains at its set position.
Electronic cut out
Vitalise SL and SLX include a 2 stage electronic cut out feature.
Stage 1
If a high water temperature is sensed, the unit will automatically switch down one heat setting until a comfortable temperature is
reached. This procedure repeats every few seconds if the temperature is still too high and may include cycling from High > Medium >
Low > Cold.
After use, if the power to the shower is NOT isolated, the last used heat setting (determined by the Electronic cut out) will be
automatically applied.
If power to the shower IS applied after use, at next operation, the shower will start in default, COLD heat mode.
Stage 2
If an extreme water temperature is sensed, the unit will flash all heat setting button lights (Vitalise SL) / LCD screen flash red, stating
“Over heat” (Vitalise SLX) and will automatically shut the heater element(s) down. Cold water will flush through the unit before
turning the water off. All lights will remain illuminated (Vitalise SL) / The LCD screen will display fault message E2
(Vitalise SLX) with the Start/stop button pushed in to indicate the unit is in fault mode. The lights and error message will
15
remain on and the unit in fault mode until the Start/stop button is pressed to turn the unit off.
User guide
!
Please refer to the separate user guide booklet provided.
After installation
Inspection & maintenance
In the interest of safety, we recommend the Vitalise range and its electrical installation are checked by a qualified electrician
at least every 2 years.
After installation
Familiarise the end user with the Vitalise product operation and hand them this guide.
Complete and post the Vitalise guarantee card and optional guarantee extension agreement document.
Cleaning and maintenance
Your Vitalise product should be cleaned using only a soft cloth and washing up liquid.
DO NOT USE ABRASIVE CLEANERS.
To reduce the requirement for chemical descaling in hard water areas, the shower head incorporates rub clean teats. Any scale
build up that may occur in any of the holes can be broken down by gently rubbing the flexible tips of the jets during use. This
procedure should be completed regularly, as often as once a week in some hard water areas as scale build up can affect the
spray pattern and cause the shower to perform poorly. Failure to descale the shower head can affect the internal seals and may
affect the warranty.
Should chemical descaling of the head become necessary, remove the shower head and fully immerse in a mild proprietary
descalent.
! IT IS IMPERATIVE THAT DESCALING IS CARRIED OUT STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS
INSTRUCTIONS. SUBSTANCES THAT ARE NOT SUITABLE FOR PLASTICS AND ELECTROPLATED SURFACES MUST
NOT BE USED.
Cleaning the filter
Cleaning the filter should only be completed by a competent person.
1. Turn the power supply to the shower off at the consumer unit or mains fuse board.
2. Isolate the water supply to the shower.
3. Remove the fixing screws from the front cover, detach the solenoid connector(s)
and pull the front cover clear.
4. Unscrew using a large flat bladed screwdriver if required and remove the
filter assembly from the shower unit inlet.
! For rear and bottom fed inlet connections, it may be necessary to remove the unit
from the wall.
5. Clean the filter assembly as necessary.
6. Refit the filter assembly and protective cover. Reassemble the unit in reverse
16
of the above procedure.
Trouble shooting guide
! These checks must only be performed by a competent person.
Warning! There are no user serviceable components beneath the cover of the appliance.
IF YOU ARE UNABLE TO REMEDY THE PROBLEM WITHOUT REMOVING THE COVER, YOU SHOULD CONTACT YOUR
INSTALLER OR A QUALIFIED ELECTRICIAN.
Only a competent tradesperson should remove the front cover.
!! The electrical supply to the shower MUST BE isolated at the consumer unit (fuse board) prior to the front cover
being removed!!
Where the fault cannot be corrected by yourself or your installer, DO NOT REMOVE THE UNIT FROM THE WALL, but
contact the Customer Services Department, who will provide assistance over the telephone. If necessary, they can
arrange a visit by a service engineer. We find the vast majority of problems can be resolved by reference to these
fitting instructions or by discussion over the telephone. In the event an engineer is called and the fault is caused by
faulty installation, usage or lack of reasonable maintenance, a call out charge will be made.
Pressures
To ensure optimal performance and that the shower is working to specification:• Try reducing the flow rate (increasing demand temperature) to increase dynamic pressure and selecting the
appropriate heat setting to give required showering temperature.
• Check inlet requirements (see Important Information - Pressures section).
• Ensure no other main water devices are being used whilst showering (e.g. toilet, garden hose, washing
machine, etc).
• Check pipework for potential blockages/pressure losses.
• Ensure the stop cock and servicing valves are fully open. Ensure full bore isolation valve has been fitted.
• Check with the local water authority to check the running pressure is above the minimum required (see
Important Information – Pressures section). This may be apparent during periods of high demand or when
other outlets are used.
IF YOU ARE UNABLE TO REMEDY THE PROBLEM WITHOUT REMOVING THE COVER, YOU SHOULD
CONTACT YOUR INSTALLER OR A QUALIFIED ELECTRICIAN.
ACTIONS HIGHLIGHTED IN BOLD TEXT MUST BE COMPLETED BY A QUALIFIED
INSTALLER/ELECTRICIAN/SERVICE ENGINEER AS STATED.
17
Will not switch on – power light
lit/LCD screen shows 3 dashes
- No power (power light indicator on unit not lit)
Will not switch on – power light
not lit/LCD screen blank
This is a non-user serviceable part, shower component
must be replaced Contact Customer Services
Department
Shower has overheated. This is a non-user serviceable
part, shower component must be replaced
Contact Customer Services Department
Permanent thermal trip activated
Faulty on/off button/switch
See trouble shooting pressures section
Check 230/240V at shower terminal block (Installer/
electrician only task) Possible wiring fault or poor
connections
Low pressure/water supply turned off (low pressure
indicator on unit lit when unit is operated, or red screen
with low pressure message for Vitalise SLX models)
If fault persists contact your installer
- Incorrectly wired product
Check isolator switched on, and remains on (pull cord or
wall mounted switch)
Check MCB or fuse at consumer unit
Check RCD (if fitted)
Renew the fuse or reset MCB/RCD if required
Action
- Power cut
- Fuse blown or MCB/RCD tripped, indicating possible
electrical fault
- Electrical supply isolated at double pole switch
Possible cause
Trouble shooting guide
Symptom
18
Fit correct hose/handset
Replace damaged/kinked hose
Turn temperature control knob anti-clockwise (towards cold)
If so, DO NOT USE
a) Switch off immediately at the electrical isolation switch
b) Turn off at isolation valve
c) Contact our Customer Service Department
Incorrect hose/handset fitted
Damaged/kinked hose
Water temperature control knob is turned fully
clockwise (full hot)
SHOWER UNIT IS SUSPECTED OF BEING FROZEN
a) If water flows then handset is blocked with scale or
debris. Clean the handset and spray plate thoroughly
b) If the water does not flow, remove the hose from the
shower unit
i) If the water flows the hose is blocked. This could be
due to damage, severe kinking or even an obstruction.
The hose must be replaced with an approved hose.
Contact our Customer Service Department
ii) If the water does not flow, there is a blockage in the
plumbing to the shower, or the shower itself or the filter
iii) Contact the Customer Service Department if you
suspect the shower to be at fault
Disconnect handset from hose and run the shower
See trouble shooting pressures section
Low pressure/water supply turned off (low pressure
indicator on unit lit when unit is operated, or low
pressure message on screen & screen is red for Vitalise
SLX)
No flow or Not enough flow
(See also poor spray pattern
below)
There may be an outlet blockage
Action
Possible cause
Symptom
Trouble shooting guide
19
Flow adequate but water too
cold, or not hot enough
Reduce the flow by slowly turning the temperature control
knob in a clockwise direction (towards hot).
Note: For Vitalise SL & SLX units, if the knob is turned to
select too hot a temperature, the safety temperature switch
inside the shower will turn off the heater elements until a
suitably lower temperature is reached. If this happens turn
the knob anti-clockwise (towards cold) to increase flow and
adjust power setting as required
Increase heater setting (note: for Vitalise SL & SLX only,
when turned on after the power has been isolated the
default power setting is no power (cold))
Incorrect heater setting
Water flow too high
Replace. In hard water areas consider the use of a water
softener – contact Customer Services Department
Replace – contact Customer Services Department
Heater tank excessively scaled
Flow valve faulty
NB It is unlikely to achieve the requirements with a
header tank
Check flow rate/pressure – see trouble shooting pressures
section
Remove filter for inspection – refer to Cleaning and
Maintenance section
Blocked inlet filter
No flow or Not enough flow
(See also poor spray pattern
below)
Inlet flow rate insufficient
Action
Possible cause
Trouble shooting guide
Symptom
20
Shower has overheated. This is a non-user serviceable
part, shower unit must be replaced.
Contact Customer Services Department
Permanent thermal trip has operated
Low inlet temperature (seasonal conditions)
Possible failure of microswitch or heater element
Sensitive adjustment
Increase heat setting & temperature knob as required.
Note: At times of extreme cold water inlet temperatures
you may only be able to achieve a warm shower.
Use a suitable continuity device to check the continuity
of the microswitch or heater tank and replace parts as
necessary (Installer/electrician only task). Contact
Customer Services Department.
Slowly adjust dial waiting for temperature to settle in
between changes.
Shower has overheated.
Increase the flow by slowly turning the temperature control
knob in an anti-clockwise direction, and change
power/heater setting if required.
Switch off unit, allow to cool, and on again to reset.
See trouble shooting pressures section
Pressure switches not activating/ Low water pressure
(low pressure indicator on unit should be lit, or low
pressure message on screen & screen is red for Vitalise
SLX).
Over temperature device (Vitalise SL + SLX) or temporary
thermal trip has activated
See trouble shooting pressures section
Insufficient water supply
Flow adequate but water too
cold, or not hot enough
Action
Possible cause
Symptom
Trouble shooting guide
21
Water too hot
Contact Customer Services Department
Increase the flow by slowly turning the temperature
control knob in an anti-clockwise direction (towards cold).
Note: For Vitalise SL & SLX units, if the knob is turned to
select too hot a temperature, the safety temperature switch
inside the shower will turn off the heater elements until a
suitably lower temperature is reached. If this happens turn
the knob anti-clockwise (towards cold) to increase flow and
adjust power setting as required.
See trouble shooting pressures section
Faulty flow valve
Water flow too low
Replace. In hard water areas consider the use of a water
softener. Contact Customer Services Department
Consult a qualified electrician
Heater tank excessively scaled
Flow adequate but water too
cold, or not hot enough
Action
Low voltage
Possible cause
Trouble shooting guide
Symptom
22
Temperature varies
dramatically while showering
Incorrect hose/handset fitted
Flow adequate but water too hot
or unstable
See trouble shooting pressures section
See trouble shooting pressures section
Water pressure too low (low pressure indicator on unit
should be lit, or low pressure message on screen &
screen is red for Vitalise SLX models)
Water pressure too low
Remove for inspection - see cleaning and maintenance
section
Debris in inlet filter
Fit correct hose/handset
Clean handset spray plate - see cleaning and maintenance
section
Spray plate blocked with scale or debris
Incorrect hose/handset fitted
Reduce heater setting
Replace damaged/kinked hose.
Fit correct hose/handset
Action
Incorrect heater setting
Damaged/kinked hose
Possible cause
Symptom
Trouble shooting guide
23
Poor spray pattern.
(refer also to handset
instructions)
Clean handset - see cleaning & maintenance section
Replace damaged/kinked hose
Flow rate will naturally be lower when the inlet
temperature is low, this applies to all electric showers.
Consult a qualified electrician
Partially blocked handset
Damaged/kinked hose
Low water inlet temperature
Low voltage
activated
Temperature setting too high/Over temperature device
does so)
Shower has sensed a high outlet temperature and is
reducing the power setting to reduce temperature until
the temperature dial/power setting is adjusted
correctly.
Turn the knob anti-clockwise (towards cold) to increase
flow and adjust power setting as required
See trouble shooting pressures section
Increase the flow by turning the temperature control
knob in an anti-clockwise direction (towards cold)
and/or reduce the heater selection to reduce the outlet
temperature
Temperature setting too high/Thermal cut out
Temperature drops dramatically
while showering (& stays low)
Clean handset spray plate - see cleaning and
maintenance section
Spray plate blocked with scale or debris
Temperature varies dramatically
while showering
operating (normally making a “click sound” as it
Action
Possible cause
Trouble shooting guide
Symptom
24
Drip from shower
head
Leaking
Water runs from around the hose
when shower is in use
Pressure Relief Device (PRD) has operated due to excess
Water runs from bottom of unit
when shower is in use
Partially blocked/scaled handset
Remove hose & handset, empty the hose & handset of
Flow valve faulty
Clean the handset – see cleaning and maintenance section
Department
If so unit needs replacing, please contact Customer Services
continue.
water, then reattach, and see if drips from handset
Tighten hose connections
Consult Customer Services Department
be used
been used. The copper olive provided (not brass) must
fully tightened. Ensure brass inlet fitting provided has
Ensure pipe is correctly fitted and compression nut is
Ensure hose is correctly fitted and tight
Ensure hose washer is fitted correctly
Ensure the correct supplied handset is used and clean
from limescale. Ensure the hose is not damaged or kinked.
Turn off the electrical isolating switch and service valve –
contact Customer Service Department.
Action
Shower head draining
Internal seals/unit leaking
Inlet connection leaking
fitted/missing
Hose incorrectly fitted, or hose washer incorrectly
or blocked
activated because of the shower outlet being reduced
pressure build-up in the head or hose. This has
Possible cause
Symptom
Trouble shooting guide
25
Clean handset spray plate - see cleaning and maintenance
Spray plate blocked with scale or debris
Replace – contact Customer Services Department
Flow valve faulty
Replace – contact Customer Services Department
Switch off at consumer unit or mains fuse board.
Remove front cover ensuring the service tunnel is
PCB failure (Vitalise SL & SLX only)
Cover/knob fitted incorrectly, knob not correctly
engaged
correctly and ensure cover is correctly fitted
per pages 7 and 14, taking care to position knob
correcty fitted flush with the unit back plate. Refit as
Replace – contact Customer Services Department
Microswitch failure
softener. Contact Customer Services Department
Replace. In hard water areas consider the use of a water
and maintenance section. Check inlet supply
valve / stopcock)
Heater tank failure/ Heater tank excessively scaled
Remove for inspection – clean as necessary, see cleaning
Partially blocked filter or restriction on supply (isolation
section
Fit correct hose/handset
Incorrect hose/handset fitted
Operation of temperature
control has little or no effect on
water temperature
Action
Possible cause
Trouble shooting guide
Symptom
26
Unit shuts itself down
(Vitalise SL & SLX models only)
Insufficient inlet pressure
No change in temperature
between low/medium/high
setting
condition. N.B. The ‘Start/stop’ button is still depressed.
remain on steady to indicate the unit is in fault
while shutting down, then lights around all buttons
Vitalise SL flashes lights around all heat select buttons
and overheat on screen while still on, in fault condition,
Heat’ & ‘Shutting Down’ while shutting down, then E2
Vitalise SLX shows red screen flashing ‘Over
Extreme over temperature protection operating
Possible failure of PCB (Vitalise SL & SLX only)
Possible failure of flow valve, heater tank or microswitch
Possible cause
Symptom
Trouble shooting guide
27
Resolve cause of high temperature, then press start/stop
button once to turn off, then again to turn on the shower
(note: on start—up the water standing in the incoming
pipework may be at higher temperatures than the normal
inlet water, if this is the case this will give higher
temperatures than the last shower until the standing water
is cleared, if this is the cause adjust temperature control
knob/heater settings to compensate while clearing
standing water then restore normal showering settings)
Replace if necessary – Contact Customer Services
Department
Use a suitable device to check the continuity of the
microswitch or heater tank & replace parts as necessary –
contact Customer Services Department
See trouble shooting pressures section
Action
Trouble shooting guide
Symptom
Possible cause
Action
Time for water to run when
shutting down varies
(Vitalise SL and SLX)
No fault – intelligent phase shut
down
The time required for phase
shut down is dependent on
how long it takes to reach a
low water temperature, once
the required temperature is
reached the unit shuts off
instantly
E1 on screen for Vitalise SLX
models/low pressure light
flashing on Vitalise SL models
& shower does not operate
Faulty temperature sensor
Replace – contact Customer
Services Department
Fault finding error messages
Fault indication for S
• If the starting pressure is less than 0.7 bar when the shower is turned on, the “Low Pressure” warning light will
illuminate red.
Fault indication for SL
• If the starting pressure is less than 0.7 bar when the shower is turned on, the “Low Pressure” warning light will
illuminate red.
• If extreme outlet temperatures are reached the unit will initiate a safety phase shut down, with the lights around
the heat select buttons flashing. Once shut down the lights around the buttons remain on constantly to indicate
an error state. The Start/stop button remains in the “ON” position but there is no water flow. To reset, press the
‘Start/stop’ button twice.
Fault indication for SLX
• If the starting pressure is less than 0.7 bar when the shower is turned on, the “Low Pressure” text will flash on the
LCD display and the LCD will be backlit red.
Low Pressure
Low pressure display
28
• If extreme outlet temperatures are reached, the unit will initiate a safety phase shut down. Under this condition,
the screen will flash red and “Over Heat” and the elements will switch off. Water flow will be flushed through the
unit before stopping.
Over temperature alarm display
Fault codes
• If the unit has a temperature sensor failure, the unit will default into E1 error mode, the shower will not operate
in this mode. The LCD will display “E1”, it will flash and the LCD will be backlit red.
Temperature sensor failure display
• After the Over Temperature alarm display, the unit will default into E2 error mode, in this state, the Start/stop
button remains in the “ON” state, but there is no water flow. To restart the unit, the Start/stop button must be
pressed twice. The LCD will display the “Over Heat “ text, and an error code “E2” and will not be backlit.
Over heat
29
Notes
30
Approvals
The Aqualisa Vitalise range is manufactured in an ISO 9001:2000 registered factory and has been designed and tested
to the very highest standards. It complies with all relevant international standards for safety and reliability.
31
Aqualisa Products Limited
The Flyer’s Way
Westerham Kent TN16 1DE
Customer helpline: 01959 560010
Brochure Hotline: 0800 652 3669
Website: www.aqualisa.co.uk
Email: [email protected]
Republic of Ireland
Sales enquiries: 01-864-3363
Service enquiries: 01-844-3212
Part No: 700130 Issue 1 Jul 12
Please note that calls may be recorded for training and quality purposes
The company reserves the right to alter, change or modify the product specifications without prior warning
® Registered Trademark Aqualisa Products Limited
Pdf Supplied By http://www.plumbworld.co.uk/