User and Installation Instructions
SmartVent Range of Extraction Canopies
SV1212, SV1216, SV1220 & SV1224
– LH/LV/CH/CV/RH/RV
IS554 ECN3755
Please read the following carefully before using this appliance.
Warnings and Precautions
Please ensure that all commissioning checks and initial start-up procedures have taken place.
This manual should be kept in a safe and accessible place for future reference.
This appliance is designed for professional use and must only be operated by qualified personnel.
Please ensure that the appliance is serviced regularly by a suitably qualified engineer.
It is mandatory that all appliances are installed, commissioned and serviced by a qualified and
competent person as defined by the regulations in force in the country of installation (see below).
Failure to comply will invalidate the warranty.
•
•
•
•
•
•
•
Health and Safety at Work Acts
IEE regulations
BS Codes of Practice
Local and National Building Regulations
Fire Precautions Act 1971
DW172
BS6173: 2009
WARNING
•
•
•
•
•
•
•
•
•
Competent personnel familiar with the assessment of hazards and risks associated with
industrial ventilation equipment such as fans and air handling units should install this
product.
Use lifting equipment which has a suitable safe working load for the SmartVent being lifted.
Ensure steps, podium steps, scissor lift or mobile scaffold tower are secure and stable before
use.
Make sure the SmartVent is fully secure before removing the support stands.
Disconnect the unit from the electricity supply before servicing or undertaking any electrical
maintenance.
Parts of this unit may become hot in normal use; suitable precautions must be taken to avoid
accidental contact.
A means of disconnection must be incorporated in the fixed wiring having a contact
separation of at least 3.0mm in all poles.
A gas interlock (supplied by others) conforming to functions described in CAIS23 and
TB140 must be installed if the SmartVent is to be used over gas appliances.
Connection to the premises electrical circuit is via two separate supplies.
IS554 ECN3755
2
SECTION 1 - TECHNICAL DATA
SMARTVENT
SV1212/16/20/24
700
1200, 1600, 200 & 2400
1200
63·5, 77·2, 91, 104·6
1 ph 230VNAC
905
2160
5
2·33
1
Description
Product Code
Height of Hood (mm)
Width (mm)
Depth (mm)
Weight (Kg)
Voltage
Motor Impeller (rpm)
Motor Max Flow Rate (m³/hr)
Motor Starting Current (A)
Motor Max. Current (A)
Light Circuit (A)
MODEL INDENTIFICATION (SV1220CH USED AS EXAMPLE)
2000
1200
12
20
Lighting
700
EXHAUST
H
Baffle Filters
2m to
finished floor
L = LEFT
R = RIGHT
C = CENTRE
H = HORIZONTAL
V = VERTICAL
Baffle Filters
C
Removable Grease Drawer
Note: the exhaust may exit at the left, centre or right and either horizontally or vertically,
depending on the model purchased.
SECTION 2 – INSTALLATION
2.1. PREPARATION
Remove all packaging prior to installation. Remove all protective coating from locating contact surfaces.
2.2. SITING
The appliance must be installed in accordance with the appropriate regulations listed prior.
The appliance should be installed level at a height of 2m off the finished floor from the lower front
leading edge.
IS554 ECN3755
3
2.3.1 MOUNTING – CENTRALLY MOUNTED FANS
280
520
125
130
Identify a suitable location with access to outside, for horizontal or vertical extraction.
Ensure the wall identified is of a suitable structure to support the Smartvent.
Remove the baffle filters. This will reveal the mounting braces on the interior back panel of the
Smartvent.
Four mounting holes for M8 are provided, but additional fixings may be required, dependent on
wall/partition structure.
280
500
1100
SV1224
920
280
125
130
SV1212
280
500
500
700
SV1216
500
SV1220
2.3.2 MOUNTING – LEFT AND RIGHT MOUNTED FANS
If installing a hood with a left or right hand located fan motor, the installer will need to create bespoke
fixing holes in the fan mounting panel.
2.4. DUCTWORK CONNECTION
321
SV1224CV
321
126
126
Ensure exhaust hole is created prior to mounting.
Vertical Outlet
360
360
SV1212CH
Horizontal Outlet
Ductwork (supplied by others) is only required to take the exhaust to outside with a suitable exit fitting
(wall vent or roof mushroom, for example) as the fan motor is housed within the SmartVent.
IS554 ECN3755
4
Long duct runs (ground floor to second storey roof, for example) may need a second duct-mounted motor.
2.5. ELECTRICAL SUPPLY AND CONNECTION
Connection of two electrical supplies is required. Necessary cable entries will be made by the installer.
The lights are supplied connected in parallel. A connection to the premises lighting circuit will be
required by simple connection into one of the end downlighting LED lamps. Note the L, N and E
connections are clearly marked.
Insert small driver here
to flip off safety cover
Cable Restraint
LEN N EL
The motor should be connected to a fan speed controller (supplied by others). The motor has an L and N
feed to the terminal block and an earth to the motor body casting.
Thermal
Protector
Motor
Capacitor
Supply
Neutral
Supply
Live
From Fan Speed Controller
IS554 ECN3755
5
2.6. COMMISSIONING
2.6.1. OPERATION
Turn on the power supply at the fan speed control. Run the fan through the range of the controller. If
operating over gas appliances, test for the lowest fan setting prior to interlock activation.
Check the lights by operating the relevant light switch. These are not dimmable lights. Do not connect to
a dimmer switch.
2.6.2. SHUTTING DOWN THE APPLIANCE
Turn off the Smartvent at the fan speed controller and light switch. This will also trip the interlock (if a
gas installation) if the gas supply has not already been isolated.
Ensure that the person responsible understands how to safely operate, clean and shutdown the
appliance.
Note: This manual must be kept in a safe and accessible place for future reference.
SECTION 3 – USER INSTRUCTIONS
3.1. PREPARATION
Before using the appliance for the first time, ensure all protective plastic has been removed and baffle
filters are in place.
3.2.1. OPERATION
Switch on the fan speed controller and energise the gas interlock. You are now ready to operate. Ensure
the installer has advised you the lowest setting to safely operate the SmartVent without nuisance
activation of the gas interlock.
3.2.2. SHUTTING DOWN THE APPLIANCE
Turn off the SmartVent at the fan speed controller and light switch. This will also trip the interlock (if a
gas installation).
Warning: After operation, some parts of the appliance may remain hot for a period of time if above
appliance flues. Please take care to avoid accidental burns.
3.3. CLEANING
Ensure the unit is isolated from the mains supply before commencing cleaning.
Disconnect appliances under the SmartVent where possible and move away for ease of access.
Remove the baffle filters and clean separately with a mild detergent and water.
Remove the grease drawers, empty and clean separately with a mild detergent and water.
Wipe off any food vapour residue on the interior face of the SmartVent and wash down with a mild
detergent and water. Rinse to ensure that all traces of detergent have been removed.
Do not use abrasive cleaners or any containing chlorine.
Do not use a water jet to clean the appliance.
IS554 ECN3755
6
SECTION 4 – COMPONENT REPLACEMENT
4.1. LIGHT REPLACEMENT
1. Disconnect the mains supply, then disconnect the affected light.
2. Turn through 90° to release the springs from the mounting spacer.
3. Allow the short spring section to drop through the hole in the hood, then raise the long spring section
to allow the whole fitting to exit through the mounting hole.
4. Fit the new downlight LED lamp by reversal of the above procedure. Ensure the mounting spacer has
secured the light in place.
4.2. MOTOR REPLACEMENT
1. Isolate the power supply at the fan speed controller or the distribution board.
2. Remove the baffle filters necessary to access the motor. This is achieved by sliding the filter up a
short distance (no more than 20mm) and swinging out from the base.
3. Either one or two of the filter infills will need to be removed. The necessary infills are screwed in (the
remainder are riveted and not intended to be removed). If the infill appears down the centre of the
motor, check the upper and lower edges for the fixing screws and remove with a T15 Torx driver. If
two infills overlap the motor at each end, these will be removable by the same procedure.
4. Disconnect the motor supply connection (see page 5).
5. Mark each motor support bracket screw mounting hole, for future reference when re-mounting the
motor.
6. Remove the two self-tapping screws holding the motor to each support bracket and carefully
withdraw the motor from the SmartVent.
7. Fit the motor by reversal of the above procedure ensuring the motor is relocated correctly inside the
exhaust flange.
4.3. REPLACEMENT COMPONENT LIST
PART
NUMBER
FA126
FI40
LA340
DESCRIPTION
0·12kW Centrifugal Fan
Baffle Filter
7W LED Downlight Lamp
LA340
LED Downlighter
FI40
Baffle Filter
Note mounting holes
FA126
Fan Motor
IS554 ECN3755
7
SERVICE INFORMATION
For help with the installation, maintenance and use of your Lincat equipment, please contact our service
department:
UK:
01522 875520
For non-UK customers, please contact your local dealer.
All service work, other than routine cleaning should be carried out by one of our authorised service
agents. We cannot accept responsibility for work carried out by other persons.
To ensure your service enquiry is handled as efficiently as possible, please tell us:
•
•
•
•
Brief details of the problem
Product code
All available on serial plate
Type number
Serial number
}
Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance,
during normal working hours, Monday to Friday, 08:30 to 17:00.
GUARANTEE
This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is in addition to, and does
not diminish your statutory or legal rights.
The guarantee does not cover:
• Accidental damage, misuse or use not in accordance with the manufacturer’s instructions
• Consumable items
• Damage due to incorrect installation, modification, unauthorised service work or damage due to
scale, food debris build-up, etc.
The manufacturer disclaims any liability for incidental, or consequential damages.
Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out
the warranty work.
Service calls to equipment under warranty will be carried out in accordance with the conditions of sale.
Unless otherwise specified, a maximum of 15 minutes of administrative time, not spent directly carrying
out servicing work, is provided for within the warranty. Any requirement for staff attending the call to
spend greater time than 15 minutes due to administrative requirements, such as on health and safety risk
assessments, will be chargeable at the prevailing rate.
IS554 ECN3755
8

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What is the height of the Lincat SV1224?
The height of the Lincat SV1224 is 700 mm.
What is the width of the Lincat SV1224?
The width of the Lincat SV1224 is 2400 mm.
What is the depth of the Lincat SV1224?
The depth of the Lincat SV1224 is 1200 mm.
What is the weight of the Lincat SV1224?
The weight of the Lincat SV1224 is 104.6 kg.
What is the voltage of the Lincat SV1224?
The voltage of the Lincat SV1224 is 1 ph 230VNAC.
What is the motor impeller speed of the Lincat SV1224?
The motor impeller speed of the Lincat SV1224 is 905 rpm.
What is the motor max flow rate of the Lincat SV1224?
The motor max flow rate of the Lincat SV1224 is 2160 m³/hr.
What is the motor starting current of the Lincat SV1224?
The motor starting current of the Lincat SV1224 is 2.33 A.
What is the motor max current of the Lincat SV1224?
The motor max current of the Lincat SV1224 is 1 A.
What is the light circuit of the Lincat SV1224?
The light circuit of the Lincat SV1224 is 5 A.