Overview

There are currently four models in the OnCell G3101/G3201 series of IP-modems: the OnCell G3111, OnCell G3151, OnCell G3211, and OnCell G3251. The main difference between the models is the serial interface type and number of ports. The OnCell

G3101/G3201 industrial RS-232, RS-232/422/485 GSM/GPRS IP modems are some of the most affordable, and versatile products available in the cellular networking market today. These modems also provide remote access and TCP/IP support, and can be configured over a network.

Package Checklist

Before Installing the OnCell G3101/G3201 series, verify that the package contains the following items:

Standard Accessories

• Document & Software CD

Omni 1 dBi rubber SMA antenna

(model name: ANT-CQB-ASM-01)

• DIN-Rail Kit

DC Power Supply (screw-on)

Rubber stand

• Product warranty statement

• Quick Installation Guide

Optional Accessories

• Quad-band GSM/GPRS antennas for OnCell G3101/G3201 series (impedance = 50 ohms):

ANT-CQB-AHSM-00-3m: Omni 0dBi/10cm, magnetic

SMA quad-band antenna (impedance = 50 ohms), 3 m

ANT-CQB-AHSM-03-3m: Omni 3dBi/25cm, magnetic

SMA quad-band antenna (impedance = 50 ohms), 3 m

ANT-CQB-AHSM-05-3m: Omni 5dBi/37cm, magnetic

SMA quad-band antenna (impedance = 50 ohms), 3 m

Note: Please notify your sales representative if any of the above items are missing or damaged.

– 1 –

P/N: 1802031010011

Hardware Introduction

Top View

Front Views

Rear Views

Bottom Views

Reset ButtonPress and hold the Reset button for 5 sec to load

factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds).

At this point, you should release the reset button (the default IP is

192.168.127.254).

– 2 –

LED Indicators

The LED indicators on the front panel of the OnCell G3101/G3201 are described in the following table.

Type

PWR

TX/RX

GSM/GPRS

Ready

Signal

(3 LEDs)

Color LED Function

Green Activation of DC Power.

Off Power is off, or power error condition exists.

Green The serial port is transmitting data

Amber The serial port is receiving data.

Off

No data is being transmitted or received through the serial port.

Green GSM is connected.

Amber GPRS is connected.

Off GSM/GPRS is disconnected.

Green

Steady on: Software Ready.

Blinking slowly (1 sec): The OnCell has been located by the OnCell Search Utility.

Steady on: Booting up, or IP fault.

Red

(Over

Green)

Blinking rapidly (0.5 sec): IP conflict.

Blinking slowly (1 sec): Cannot get an IP address from the DHCP server.

Off Booting up or there is no error condition.

Green

Number of lit LEDs indicates signal level

(at least 2 LEDs must illuminated for data transmission)

Adjustable pull high/low resistor for RS-485 Port

DIP switches on the bottom of the OnCell G3151/G3251 are used to set the pull high/low resistor value for each serial port.

SW

ON

OFF

1

Pull High

1 KΩ

150 KΩ

2

Pull Low

1 KΩ

150 KΩ

3

Terminator

120 Ω

---

4

---

---

---

NOTE If the pull high/low resistor on your device is already set for

RS-485, make sure the default SW for RS-232 is “OFF” when you switch back to RS-232 interface.

Hardware Installation Procedure

STEP 1: Open the SIM cover, and insert the SIM card in the SIM card slot.

STEP 2: Connect the 12-48 VDC power adaptor to the OnCell

G3101/G3201 series and then plug the power adaptor into a DC outlet.

STEP 3: To configure the OnCell, use an Ethernet cable to connect the OnCell directly to your computer’s Ethernet interface.

STEP 4: Connect the OnCell G3101/G3201 series’s serial port to a serial device.

– 3 –

DIN-Rail Mounting

The OnCell G3101 and G3201 series have built-in “ears” for attaching the IP modem to a wall or the inside of a cabinet. We suggest using two screws per ear to attach the IP modem to a wall or the inside of a cabinet. The heads of the screws should be less than 6.0 mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown in the figure at the right.

Software Installation Information

The Document & Software CD contains the User’s Manual, OnCell

Search Utility, and OnCell Driver Manager. Insert the CD and follow the on-screen instructions. Please refer to the User’s Manual for additional details on using the OnCell Search Utility and Driver

Manager.

Pin Assignments and Cable Wiring

DB9 Male Port Pinouts

Note that the OnCell G3111 and G3211 only support RS-232. The

RS-422/485 pin assignments only apply to the OnCell G3151 and

G3251.

DB9 Male OnCell G3111/G3211 (RS-232)

4

5

6

7

Pin

1

2

3

8

9

RS-232

DCD

RxD

TxD

DTR

GND

DSR

RTS

CTS

---

– 4 –

DB9 Male OnCell G3151/G3251 (RS-232/422/485)

4

5

6

7

Pin RS-232 RS-422/485-4w RS-485-2w

1 DCD TxD-(A) ---

2

3

RxD

TxD

TxD+(B)

RxD+(B)

---

Data+(B)

8

9

DTR

GND

DSR

RTS

CTS

---

RxD-(A)

GND

---

---

---

---

Data-(A)

GND

---

---

---

---

Specifications

Cellular Interface

Standards

Band Options

GSM/GPRS

Quad-band 850/900 and 1800/1900 MHz

GPRS Multi-slot Class Class 10

GPRS Terminal Device

Class

Class B

GPRS Coding Schemes CS1 to CS4

Tx Power 1 watt GSM 1800/1900, 2 watts EGSM

850/900

3 V SIM Control

LAN Interface

Number of Ports

Ethernet

Magnetic Isolation

Protection

1 (For configuration only)

10/100 Mbps, RJ45 connector, Auto

MDI/MDIX

1.5 KV built-in

SIM Interface

Number of SIMs

SIM Control

Serial Interface

Number of Ports

Serial Standards

ESD Protection

Power EFT/

Surge Protection

1

3 V

Serial Communication Parameters

Parity

Data Bits

None, Even, Odd, Space, Mark

5, 6, 7, 8

Stop Bit(s)

Flow Control

Baudrate

Serial Signals

RS-232

RS-422

1 or 2

G3111: 1 RS-232 port

G3151: 1 RS-232/422/485 port

G3211: 2 RS-232 ports

G3251: 2 RS-232/422/485 ports

15 KV

2 KV

1, 1.5, 2 (when parity = None)

RTS/CTS, XON/XOFF

50 bps to 921.6 Kbps

TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

Tx+, Tx-, Rx+, Rx-, GND

– 5 –

RS-485-4w

RS-485-2w

Tx+, Tx-, Rx+, Rx-, GND

Data+, Data-, GND

Management Software

OnCell Central

Manager

Centralized management solution for accessing private IPs from the Internet

(For Software download, Please check on www.moxa.com)

Physical Characteristics

Housing

Dimensions

Power Requirements

Aluminum, providing IP30 protection

111 x 77 x 26 mm (4.37 x 3.03 x 1.02 in)

Number of Power

Inputs

Input Voltage

Data Link

1 power jack

12 to 48 VDC

335 to 900 mA (peak) @ 12 V

Environmental Limits

Operating -30 to 55°C (-22 to 131°F)

Temperature

Operating Humidity 5 to 95% RH

Storage Temperature -40 to 75°C (-40 to 167°F)

Regulatory Approvals

EMC CE Class A , FCC Class A, UL

Warranty

Warranty Period 5 years www.moxa.com/support

The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)

Europe: +49-89-3 70 03 99-0

Asia-Pacific: +886-2-8919-1230

China: +86-21-5258-9955 (toll-free: 800-820-5036)

 2014 Moxa Inc. All rights reserved.

– 6 –

advertisement

Related manuals

advertisement