Hygain AV-620 VERTICAL, HF, 6 BD-20/17/15/12/10/6M Product Manual

Add to my manuals
28 Pages

advertisement

Hygain AV-620 VERTICAL, HF, 6 BD-20/17/15/12/10/6M Product Manual | Manualzz

AV-620

INSTRUCTION &

ASSEMBLY

MANUAL

WARNING:

You can be killed if the antenna, feedline, or the equipment used to install the antenna accidentally contacts utility lines. NEVER install an antenna near utility lines.

308 Industrial Park Road, Starkville, MS 39759

AV-620 Vertical Antenna

Instruction Manual

Table of Contents

Topic :

Introduction

Theory of Operation

AV-620' Specifications

Antenna Location

Antenna Mast

A n t e n n a G r o u n d i n g

Antenna Guying

Customer Supplied Components

Tools Required for Assembly

Safety Precautions

Verification of AV-620 Parts

Assembly Procedure

Installation Procedure

Tuning Procedure

Maintenance

Technical Assistance

Warranty

Table of Illustrations

Page

3

5

5

3

4

5

6

6

6

7

8

11

17

17

18

18

28

Illustration

Chart A

Chart B

F i g u r e A

F i g u r e B

Figure C

Figure D

Figure E

Figure F

Figure G

Figure H

Page

19

1 9

2 0

21

22

23

24

25

26

27

WARNING: Improper installation and assembly can be hazardous! Read these instructions thoroughly before attempting to install or operate this product. High power transmitting devices product voltages that can cause severe burns or other injuries.

Introduction

Hy-Gain is proud to produce the AV-620 HF Multiband Vertical. Drawing on our many years of HF and VHF Antenna experience, we have produced a wellengineered antenna capable of excellent efficiency, unmatched performance, and superior construction.

Computer optimization of the AV-620 design yields the most efficient electrical design with maximum gain and low angle of radiation for long distance communication. No traps are used to achieve six band performance. This eliminates any signal losses from trap coils. The AV-620 is resonant on all six bands with individual 3/8 wavelength radiators. There are no "tricks" or "mystery resonances" used for impedance matching on any band.

No long wire radials or counterpoise kits are necessary for operation of the AV-

620. The AV-620 is self contained for simple, convenient portable or fixed operation.

Mechanical construction of the AV-620 is designed for extreme light weight and high wind survival. Aircraft grade aluminum and high strength fiberglass are used for the entire radiator. The trap-free design allows a very low wind surface area. Bulky tubes are not required to support unwieldy traps. The broad 2:1

VSWR bandwidth on all bands eliminates large frequency shifts seen in other antennas when the antenna is wet or iced.

The AV-620 is covered by our Hy-Gain Warranty and supported by our customer service team. We would like to thank you for purchasing this product from us and ask that you let us know of any suggestion you may have. With proper assembly, installation, and maintenance, the AV-620 will provide years of faithful service.

Theory of Operation

The AV-620 HF Multiband Vertical antenna consists of an end fed radiator that is resonant in the 6, 10, 12, 15, 17, and 20 meter amateur frequency bands.

Resonances on each band are the result of impedance matching

a

3/8 wavelength element with a broadband RF transformer. The characteristic impedance at the base of a 3/8 wavelength radiator is in the order of several hundred ohms.

To match this impedance, a 4:1 toroidal transformer (voltage balun) steps the impedance down to 50 ohms. This transformer uses (2) ferrite cores for high power capability. Also, the windings are made of twisted pair wire to improve coupling and reduce loss. A second high power transformer is configured as a

1:1 current balun to help stop RF from traveling back to the feedline. The

radiator of the AV-620 is at DC ground potential for static drain. This is accomplished by an inductor in the matching circuit.

The center radiator is resonant on 20 meters. A small linear loading section near the top of the AV-620 shortens the overall height approximately 5 feet to a more manageable 23 feet total height. VSWR is under 2:1 across the entire 20 meter amateur band. Placed on the center radiator are 114 wavelength stubs for 6 (2 stubs), 10, 12, 15, and 17 meters. The stubs are placed approximately one tenth of a wavelength (electrically 118 wavelength) above the AV-620 base. At the top of each stub the impedance is very high at the frequency the stub is tuned. This high impedance stops, (chokes) RF at this point creating a resonant radiator.

There is minimal loss using this method as compared to standard trap circuits.

Also, VSWR bandwidth is not restricted by the "Q" of trap components.

AV-620 Specifications

VSWR at Resonance

Gain

Height

Weight

Horizontal Radiation Angle

Vertical Radiation Angle

Wind Surface Area

Wind Survival

Band(m)

20

17

15

12

10

6

2:1 VSWR

(KHz)

500

500

500

500

1500

6000

CW

(Watts Out)

1500

1500

1500

1500

1500

500

less than 1.5:1 at antenna typical

3 dBi nominal

23 feet

12 lbs

360 degrees

16 degrees at ¼ wavelength ht.

2.4 sq. ft.

80 mph

POWER SSB

(PEP Watts)

1500

1500

1500

1500

1500

500

RTTY

(Watts Out)

400

400

400

400

400

200

Antenna Location

The best performance for receiving and transmitting will be obtained by mounting the antenna in a clear location above or away from buildings, towers, feedlines, utility wires, and other antennas. While your own ingenuity and particular circumstances will determine the final mounting method, remember, all objects within 65 feet from the base of the antenna will influence the performance of the AV-620.

WARNING: Always mount this antenna so that it is out of the reach of adults as well as children and pets. The counterpoise rods can cause injury and/or severe RF burns.

NEVER mount this antenna in a location that will permit unsuspecting

people to come in contact with any part of the antenna.

NEVER mount this antenna where a mechanical failure might allow the

antenna, antenna support and feedline to contact power lines or other utility wires.

ALWAYS ground the feedline at the point where it enters a building to a

good earth ground for lightning protection.

ALWAYS follow the guidelines for antenna installations as recommended by the US Consumer Product Safety Commission.

Antenna Mast

The recommended support mast for the AV-620 is steel water pipe between the sizes of 1-

1/4" OD to 2 1/2" OD and with a length that will place the antenna base at a safe height. Do not use thin walled conduit, aluminum tubing, or "TV" mast. The AV-620 is designed to operate at a height of 8 or more feet for proper performance. Placement on the side of a house or garage at eaves level is acceptable as long as the counterpoise whips will not be in contact any snow on the roof. Placement above metal roofs is acceptable if the antenna base is at least 5 feet or more above the metal surface.

Antenna Grounding

Although the AV-620 is designed to operate efficiently without the requirement of an earth ground, SAFETY GROUNDING must still be provided to protect equipment, property and persons from the hazards of lightning strikes and other weather related electrical discharges. In addition the coaxial cable feeding the antenna should have the shield grounded to eliminate the risk of any indoor equipment failure from allowing hazardous voltages from appearing indoors and creating a shock hazard. The support mast should be grounded with a large diameter ground wire.

The AV-620 is DC grounded for static discharge. This is accomplished with a choke coil in the Matching Unit. This coil could fail under high voltage spikes from a near or direct lightning strike.

Additional protection can be accomplished by grounding the shield of the coax where it enters the building to a good earth ground or directly burying the cable in the earth for several feet before it enters the building. The coaxial cable should be totally disconnected from the station during threatening weather conditions for maximum lightning protection.

Antenna Guying

For normal operation up to 80 mph winds, the AV-620 will not require guying. For extreme locations such as tall building rooftops, a safety guy is recommended. Use

Dacron® rope to guy the center radiator. Attach ropes 14 feet above the antenna base.

Use care not to disturb the radiator stubs.

Customer Supplied Components

Quality low-loss 50 ohm coax cable with PL-259 connectors

VSWR Analyzer (MFJ-259B or equiv.) or HF transceiver with VSWR meter

Mounting mast with required hardware to provide sturdy support

Tools Required For

• 1/4" Standard Blade Screwdriver

• #1 Phillips Screwdriver

• #2 Phillips Screwdriver

• 3/8" Open End Wrench

• 3/8" Nut Driver

5/16" Nut Driver (Deep Socket)

5/16" Open End Wrench

• 7/16" Nut Driver

. 7/16" Open End Wrench

• 10 mm Open End Wrench

• Tape Measure 20'

• Suitable Eye Protection

• Pliers

0

WD-40® or equivalent

Safety Precautions

WARNING! You can be killed if the antennas, feedline, or the equipment used to install the antenna accidentally contacts any utility lines. Never install an antenna near power lines!

Be careful while climbing and carrying the antenna. It is heavy enough to cause you to lose your balance if it is handled too casually or if any part of the antenna snags on a gutter, ladder, tree, or other item.

Mount the antenna high enough and in the clear so that it is out of reach by any person or pet. Do not allow trees or other structures near the reaidator portion of the antenna.

The counterpoise whips can cause serious eye injury.

Ensure that the mast is sturdy enough to support the weight of this antenna including the windload of the antenna.

Verification of Parts

Refer to the Box Contents and Parts Bags listings below to identify all parts. Also refer to Page 10 for drawings of the various brackets used in the AV-620. If any part is missing or damaged, turn to the Technical Assistance portion of this manual. There is extra hardware supplied with the antenna.

Box Contents

Part Number Part Description

17-AV620-4 Instruction Manual Bag

17-AV620-1 Parts Bag #1

17-AV620-2 Parts Bag #2

17-AV620-3 Parts Bag #3

80-AV620-1 AV620 Matching Unit

810-0620-1 Base Insulator 1 1/4" x 12" •

810-0620-3 Radiator Insulator 1" x 6"

17-AV620-5 Base Tube 1 1/2" x 12"

17-AV620-6 Small Tube Bundle

810-0620-6

810-0620-7

810-0620-8

810-0620-9

810-0620-10

738-0620

Radiator Section 13/8" x 48"

Radiator Section 1 1/4" x 72"

Radiator Section 1 1/8" x 72"

Radiator Section 1 1/8" x 48"

Radiator Section 1" x 48"

Antenna Mounting Plate

ID Number Quantity Received

IM

PB1

1

1

PB2

PB3

NW

IN1

1

1

1

1

IN2

BA

ST

BB

BC

BD

BE

BF

AM

1

1

1

1

1

1

1

1

1

Small Tube Bundle

Part Number Part Description

810-0620-2 Stub Section 1/4" x 20"

810-0620-11 Stub Section 1/4" x 24"

810-0620-21 Stub Section 1/4" x 36"

810-0620-14 Stub Section 1/4" x 48"

810-0620-15 Stub Section 1/4" x 72"

810-0620-12 Stub Section 3/16" x 18"

810-0620-13 Stub Section 3/16" x 21"

810-0620-17 Stub Section 3/16" x 30 1/2"

810-0620-18 Stub Section 3/16" x 33"

810-0620-19 Stub Section 3_/16" x 55"

738-2760 48" Stainless Steel Whip

ID Number Quantity Received

CK

CL

1

1

CG

CF

CE

CB

CA

CD

CC

CH

CW

1

2

4

1

1

1

1

2

7

Instruction Manual Bag

Part Number Part Description

925-AV620 AV-620 Instruction Manual

925-1007 Ameritron Warrant Card

924-1780 Warning Label

Parts Bag #1

Part Number Part Description

656-03755

656-1500S

656-1750S

705-06325

660-03755

660-1500S

711-1037S

6-32 x 3/8" Screw SS

6-32 x 1 1/2" Screw SS

6-32 x 13/4" Screw SS

6-32 Ke s Nut SS

10-32 x 3/8" Screw SS

10-32 x 1 1/2" Screw SS

#10 Lock Washer SS

705-10325 10-32 Nut SS

705-1032SNL 10-32 Nut Nylon Insert SS

662-20005

662-2500S

1/4-20 x 2" Bolt SS

1/4-20 x 2 1/2" Bolt SS

705-2520SNL 1/4-20 Nut Nylon Insert SS

745-3150S Hose Clam SS

810-0620-16 Stub Slice 3/16" x 1 1/2"

745-3108 Counterpoise Rin SS

765-1009

765-1000

Plastic Ca 1/4"

Plastic Cap 1"

Parts Bag #2

Part Number Part Description

735-1610

737-1618

737-1619

Radiator Clam Bracket

Linear Loading End Strap

1 Linear Loading Bracket

Parts Bag #3

Part Number Part Description

758-9200

758-9195

2 1/2" U-Bolt Assembly SS

Mast Saddle

808-1786-6 Mast Plate

738-2600 90 Degree Stub Insulator

738-2602 180 Degree Stub Spacer

735-1611 Stub Base Bracket

11-AV620-1 Jumper Wire

ID Number Quantity Received

MN

WC

WL

1

1

7

ID Number Quantity Received

S1

S3

S4

N1

S6

S7

W1

N5

HC

SS

R1

N2

N3

S8

S9

C1

C2

ID Number

RB

LE

LB

ID Number

UB

MS

MP

P1

P2

SB

J1

28

20

2

51

12

4

10

12

12

4

4

8

3

4

2

4

1

Quantity

20

1

2

Quantity

2

2

2

8

3

3

1

_

Received

Received

90 Degree Stub Insulator

PIN 738-2600 Qty (2)

Plastic

ID# P1

180 Degree Stub Insulator

PIN 738-2602 Qty (2)

Plastic

ID# P2

Single Stub Insulator

PIN 737-8100 Qty (5)

Plastic

ID# P3

Dual Stub Base Bracket

PIN 735-1611 Qty (1)

Aluminum

ID# SB2

Single Stub Base Bracket

PIN 735-1618 Qty (2)

Aluminum

ID# SB1

Radiator Clamp Bracket

PIN 735-1610 Qty (16)

Aluminum

ID# RB

TASK I

Center Radiator Assembly

( ) Refer to Figure A to assemble the Center Radiator. Attach BA tubing section to the

Base Insulator (rNl) with (2) 1/4-20 x 2" bolts (S8) and 1/4-20 nylock nuts (N5). Do not tighten the nuts at this time.

( ) Find the (2) counterpoise rings (RI). Press the ring flat sides together and slide them onto the Base Insulator (IN1). Leave rings loose at this time.

( ) Attach BB tubing section to the Base Insulator (INI) with (2) 1/4-20 x 2" bolts (S8) and 1/4-20 nylock nuts (N5). Do not tighten the nuts at this time.

( ) Place (1) hose clamp (HC) over the slotted end of tubing section BB. Slide unslotted end of BC tubing section 4 inches (10 cm) into BB. Tighten hose clamp. NOTE: For protection agaipst oxidation, a conductive paste such as NoAloxg may be used between

telescoping pieces of aluminum tubing only. D6 not apply the paste to insulators or coax connections.

( ) Place (1) hose clamp (HC) over the slotted end of tubing section BC. Slide undrilled end of BD tubing section 4 inches (10 cm) into BC. Tighten hose clamp.

( ) Insert Radiator Insulator (IN2) into tubing section BD. Attach with (2) 10-32 x 1 1/2" screws (S7) and 10-32 nylock nuts (N3). Do not tighten nuts at this time.

( ) Slide drilled end of tubing section BE over Radiator Insulator (IN2). Attach with (2)

10-32 x 1 1/2" screws (S7) and 10-32 nylock nuts (N3). Do not tighten nuts at this time

( ) Place (1) hose clamp (HC) over the slotted end of tubing section BE. Slide an end of

BF tubing section 13 inches (33.0 cm) into BE. Tighten hose clamp.

( ) The exposed length of BF is now set at 35" ( 88.9 cm). This is the 20 meter length dimension L20 and is set for center band operation. See CHART A (page 19) for: other settings.

( ) Place 1" plastic cap (C2) over top end of tubing section BF.

TASK II

Stub Base Bracket Assembly

( ) Refer to Figure B for Stub Base Bracket Assembly. Study Figures B, C and D to learn how the stubs are attached for each band. Note how the various brackets are offset 45 and/or 90 degrees for proper antenna assembly.

( ) Find the three aluminum Stub Brackets (SB). Attach a Radiator Bracket (RB) to each

Stub Bracket with (2) 6-32 x 3/8" screws (S1) and (2) 6-32 keps nuts (NI).

( ) Mount each Stub Base Bracket to the AV-620 Radiator using a Radiator Bracket

(RB) , (2) 6-32 x 1 3/4" screws (S3), and (2) 6-32 keps nuts (NI). NOTE the degrees offset for each bracket in Figure B. Position the Stub Brackets ABOVE the Radiator

Brackets.

TASK III

Stub Insulator Assembly

( ) Place the AV-620 Radiator on a flat surface such as a driveway or garage floor. This will aid in mounting the Stub Insulators by keeping them aligned with each other.

( ) Refer to Figure C for Stub Insulator Assembly. There are two types of stub insulators:

90 Degree and 180 Degree. The locations of the 90 Degree insulators are labeled "A» and the 180 degree insulators are labeled "B 1" and "B2".

( ) Find the three 180 Degree Stub Insulators (P2). Attach each one to a Radiator Bracket

(RB) using (2) 6-32 x 3/8" screws (S1) and (2) 6-32 keps nuts (Nl).

( ) Mount the 180 degree spacers on the AV-620 Radiator using a Radiator Bracket

(RB), (2) 6-32 x 1 1/2" (S3) screws, and (2) 6-32 keps nuts (NI). USE the dimensions in

Figure C to space and rotate the insulators into their proper locations. Position the Stub

Insulators ABOVE the Radiator Brackets.

( ) Find the eight 90 Degree Stub Insulators (P 1). Attach each one to a Radiator Bracket

(RB) using (2) 6-32 x 3/8" screws (S1) and (2) 6-32 keps nuts (NI).

( ) Mount the 90 degree spacers on the AV-620 Radiator in pairs using (2) 6-32 x 1 1/2" screws (S3) and (2) 6-32 keps nuts (NI). There are four pairs of 90 degree insulators.

USE the dimensions in Figure C to space and rotate the insulators into their proper locations. Position the Stub Insulators ABOVE the Radiator Brackets.

TASK IV

Stub Assembly

( ) Refer to Figure D for the stub assemblies.

( ) TEN METER STUB: Notice on the 3/16" x 30 1/2" rod CD the ends are tapped at different lengths. Thread an end of tubing section CE onto the 1" tapped length end of rod CD. Thread it on at least 3/4" (2 cm) and carefully tighten with pliers until it is tight against rod CD. Do not compress the tubing where it is threaded onto the rod.

NOTE: A small amount of WD-40® or NoAlox® can be used on these threaded connections to ease assembly. Do not use oil. WD-40

will

evaporate over time and

NoAlox is a conductive paste.

1

NOTE: THIS CONNECTION WILL NOT LOOSEN OVER TIME AS THERE IS NO

TORQUE ON THE CONNECTION WHEN THE STUB ASSEMBLY 1S MOUNTED

ON THE ANTENNA.

( ) TWELVE METER STUB: Notice on the 3/16" x 33" rod (CC), the ends are tapped at different lengths. Thread an end of tubing section (CF) onto the 1" tapped length end of rod (CC). Thread it on at least 3/4" (2 cm) and carefully tighten with pliers until it is tight against rod CC. Do not compress the tubing where it is threaded onto the rod.

( ) Thread a stub splice (SS) into the end of tubing section CF at least 3/4" (2 cm) until it is tight inside the tube.

( ) Thread an end of tubing section (CG) onto the stub splice (SS) until it reaches tubing section CF. Carefully tighten tubing section (CG) against CF with pliers. Do not compress the tubing where it is threaded onto the stub splice.

( ) FIFTEEN METER STUB: Notice on the 3/16" x 18" rod (CB), the ends are tapped at different lengths. Thread an end of tubing section (CE) onto the 1" tapped length end of rod (CB). Thread it on at least 3/4" (2 cm) and carefully tighten with pliers until it is tight against rod CB. Do not compress the tubing where it is threaded onto the rod.

( ) Thread a stub splice (SS) into the end of tubing section CE at least 3/4" (2 cm) until it is tight inside the tube.

( ) Thread an end of tubing section (CE) onto the stub splice (SS) until it reaches tubing section (CF). Carefully tighten tubing section CE against tubing section CF with pliers.

Do not compress the tubing where ibis threaded onto the stub splice.

( ) SEVENTEEN METER STUB: Notice on the 3/16" x 21" rod (CA), the ends are tapped at different lengths. Thread an end of tubing section CE onto the 1" tapped length end of rod (CA). Thread it on at least 3/4" (2 cm) and carefully tighten with pliers until it is tight against rod CA. Do not compress the tubing where it is threaded onto the rod.

( ) Thread a stub splice (SS) into the end of tubing section CE at least 3/4" (2 cm) until it is tight inside the tube.

( ) Thread an end of

another

tubing section (CE) onto the stub splice (SS) until it reaches tubing section CE. Carefully tighten tubing section CE against

the previous

tubing section CE with pliers. Do not compress the tubing where it is threaded onto the stub

( ) SIX METER STUBS: Installation of the six meter stubs is optional. If six meter operation is not desired do not attach the stubs to the radiator. Leaving the stubs off will not effect operation of the other bands. These stubs are the two 3/16" rods (CH). They are single section stubs and do not require assembly.

1

TASK V

Stub Mounting

( )

Refer to Figure E to install the stub assemblies on the AV-620 Radiator. The bottom of each stub assembly can be slid into the corresponding top stub insulator and fed through consecutive insulators until it reaches the corresponding stub bracket.

6 Meter Stubs

( ) If operation on 6 meters is desired, find the two six meter stubs (CH). Slide the threaded end of each stub through the top of the 6 meter stub insulator.

( )Mount each stub in the 6 meter stub brackets using (2) 10-32 standard nuts (N2) and a

#10 Lockwasher (WI) as shown in Figure E.

( ) Set Lengths L6A and L6B according to the desired operating frequencies in Chart A

(page

10 and 12 Meter Stubs

( ) Select the 10 meter stub assembly and slide the threaded end through top of the proper

90 degree stub insulator. Continue feeding the stub through the next three insulators.

NOTE: The 10 meter stub will pass completely through the top stub insulator.

( ) Attach the stub in the 10 meter stub bracket position using (2) 10-32 standard nuts

(N2) and a #10 Lockwasher (W 1) as shown in Figure E.

( ) Set 10 meter stub length L10 according to the desired operating frequency in Chart A

(page 19).

( ) Select the 12 meter stub assembly and slide the threaded end through top of the proper

90 degree stub insulator. Continue feeding the stub through the next three insulators.

NOTE: The 12 meter stub will pass completely through the top stub insulator.

( ) Attach the stub in the 12 meter stub bracket position using (2) 10-32 standard nuts

(N2) and a #10 Lockwasher (W 1) as shown in Figure E.

( ) Set 12 meter stub length L12 according to the desired operating frequency in Chart A.

15 and 17 Meter Stubs

( ) Select the 15 meter stub assembly and slide the threaded end through top of the proper

180 degree stub insulator. Continue feeding the stub through the next five insulators.

NOTE: The 15 meter stub will pass completely through the top stub insulator.

( ) Attach the stub in the 15 meter stub bracket position using (2) 10-32 standard nuts

(N2) and a #10 Lockwasher (WI) as shown in Figure E.

1

( ) Set 15 meter stub length L15 according to the desired operating frequency in Chart A.

( ) Select the 17 meter stub assembly and slide the threaded end through top of the proper

90 degree stub insulator. Continue feeding the stub through the next five insulators.

( ) Attach the stub in the 17 meter stub bracket position using (2) 10-32 standard nuts

(N2) and a #10 Lockwasher (W I) as shown in Figure E.

( ) Set 17 meter stub length L17 according to the desired operating frequency in Chart A.

( ) Place a 1/4" plastic cap (C1) on the open end of tubing sections for each stub assembly

(Figure E).

TASK VI

Linear Loading Assembly

( ) Refer to Figure F for assembly of the LinearLoading section.

( ) Remove the (2) 10-32 nuts (N3) from the TWO 10-32 screws (S7) shown in Figure F.

( ) Mount a Linear Loading Bracket (LB) on each screw. Position the bracket as shown in

Figure F and tighten nuts (N3).

( ) Feed 1/4" x 20 and 1/4" x 24" tubing sections (CK & CL) through the two open holes in the top pair of 90 degree stub insulators and secure each tube to a Linear Loading

Bracket (LB) with a 10-32 x 3/8" screw (S6) and #10 Lock Washer (WI).

( ) Connect the Linear Loading End Bracket (LE) to the lower ends of tubing sections CK

& CL with a 10-32 x 3/8" screw (S6) and #10 Lock Washer (WI). VERIFY the Linear

Loading End Bracket (LE) is equally spaced between the Radiator and 17 meter stub as shown in Figure F. There are no length adjustments in the Linear Loading Section.

Notice the CK & CL tubing sections are in line with the 10 and 12 Meter stubs and do not touch each other.

TASK VII

Matching Unit Mounting

( ) Refer to Figure G to find the location of where the Matching Unit (MU) is mounted.

Remove the (2) 1/4-20 nuts (N5) from the (2) 1/4-20 x 2" bolts (S8) that secure the

Matching Unit to the antenna base. Use the lower pair of bolts to mount the MU as shown in Figure G.

( ) Place the Matching Unit on the bolts and secure in place with the (2) nuts. Be sure the coax connector end of the Matching Unit faces the base (bottom) of the antenna.

( ) Using a 6-32 keps nut (N1), connect one end of the jumper wire (J1) to the

1

counterpoise terminal of the Matching Unit. Do not over-tighten this nut. The other end of the jumper wire is attached later.

TASK VIII

Counterpoise Assembly

( ) Refer to Figure G to assemble the counterpoise.

( ) Loosely attach the counterpoise rings (RI) to the base insulator (INI) with (2) 6-32 x

1 3/4" screws (S4) and 6-32 keps nuts (NI).

( ) Loosely attach the counterpoise rings (RI) together with (8) 10-32 x 3/8" screws (S6) and 10-32 nylock nuts (N3).

( ) Place the (7) 48 inch (122 cm) counterpoise whips (CW) into the slots provided in the sides of the rings. The slot facing the Matching Unit (MU) does not receive a whip.

( ) Tighten the 10-32 nuts (N3) around the rings to secure the whips.

( ) Place the loose end of jumper wire (J1) under the closest 6-32 screw(S4) that holds a ring to the base insulator as shown in Figure G. Tighten the (2) 6-32 nuts (Nl) that secure the rings to the base insulator.

( ) Attach a warning label to the end of each whip as shown in Figure

TASK IX

Antenna Mounting Plate Assembly

( ) Refer to Figure H for assembly of the Antenna Mounting Plate

( ) Place (4) 1/4-20 x 2 1/2" bolts (S9) through a Mast Plate (MP), a Mast Saddle (MS), and the antenna mounting plate (AM) and secure with 1/4-20 nylock nuts (N5). Do not tighten the nuts.

( ) Place the antenna base under the Mast Saddles and align the end of the base with the edge of the mounting plate as shown in Figure H.

( ) Tighten the (4) bolts to hold the antenna base in place. Do not over-tighten the nuts.

( ) Place the (2) U-bolt assemblies (UB) into the holes in the antenna mounting plate as shown in Figure H. Leave nuts loose until installation of the antenna.

Installation

The AV-620 antenna should be mounted at least 8 feet above ground. The main reason for this minimum height is safety. The AV-620 will work well at a minimum height of five feet but precautions from dangerous voltages must be taken.

Always have help for the installation process. Do not attempt to install the antenna alone. Review the requirements for Antenna Location and safety precautions regarding

Power Lines earlier in this manual.

The easiest method of installing the AV-620 is to first mount the Antenna Mounting

Plate (AM) on the support mast. Tighten the mounting plate U-Bolts. Have the Mast

Saddles and Mast Plates (MS & MP) loosely mounted on the mounting plate. Raise the antenna and slide the antenna base under the Mast Saddles (MS) until the antenna base is flush with the lower edge of the mast plate (Figure H). Tighten the antenna base in place.

The AV-620 may be roof mounted on a tripod or similar support. Keep the AV-620 base a minimum of 5 feet above the roof surface. This minimum dimension is the same for any roof material type. Attach a suitable ground wire to the support mast as mentioned in the Grounding section of this manual.

Tuning

The AV-620 should be checked with an VSWR meter before permanent installation to verify proper assembly and Matching Unit performance. Place the AV-620 at least 8 feet above ground and in as clear an area as possible. Connect the coax to the antenna base and test the VSWR using either an MFJ-259B VSWR Analyzer or equivalent or a transceiver and VSWR meter.

The 2:1 VSWR Bandwidth should be referenced to determine performance. VSWR measurements made at the antenna base are the most accurate and may show a slightly narrower VSWR bandwidth than the specifications chart lists. Be sure to use very low power (less than 5 watts) when measuring VSWR at the antenna base.

The AV-620 has few variables in its design. Therefore, VSWR should be very close to specifications. If any adjustments are needed, refer to Chart A (page 19) to verify dimensions and use Chart B (page 19) to calculate the amount of adjustment needed to place the AV-620 on frequency.

Do not adjust, the length of the AV-620 Radiator except at the very top section BF.

There are no adjustments in the Linear Loading Section. Only adjust BF (for 20 meters) and the individual stub bases. Each frequency band is individually adjustable.

Adjustments to individual bands will have minimal effect on other bands.

The length of coax will vary the VSWR. Lengths less than 50 feet will have stronger harmonic resonances than longer lengths. If a particular frequency will not properly resonate, try adding 3-5 feet or more of coax. Record the VSWR resonances on each band before and after adding coax. One or more of the resonance points will change. RF loss at

HF is not a major problem with RG8 or larger coax. There will be a minimal performance difference between a 50 ft. length and a 75 ft. length.

To lessen the possibility of RFI/TVI, roll up 6-8 turns of coax 8" inches diameter approximately one quarter wave (or multiple) from the base of the antenna. Use the quarter wave length of the frequency that causes the greatest amount of

Maintenance

The AV-620 should be inspected mechanically at least once a year. Normal wear and tear varies significantly with climate.

Anti-Oxidation paste such as NoAlox@ or others can be applied to the radiator tubing sections. Use small amounts. Do not place the paste on the coax connector or inside of the

Matching Unit.

Inspect the inside of the Matching Unit on a regular basis. Remove dirt, bugs, or questionable material. Look for any degradation of parts. High voltage static discharges (lightning) may cause a failure to the small coil in the Matching Unit. This coil is a protection device. Make sure it is in good shape.

Do not screw and unscrew the nylon insert nuts several times. If portable operation is desired, use stainless steel hardware without the nylon locking feature.

The AV-620 may be painted. Clean all aluminum surfaces well to improve paint adherence. Paint the antenna after it is assembled and tuned. DO NOT PAINT

PLASTIC PARTS.

Technical Assistance

Technical assistance is available during normal business hours on weekdays. Hy-Gain is located in the Central Time Zone. Our hours are 7:00 AM till 4:00 PM CST Monday through Friday.

Hy-Gain can be reached by telephone, FAX, email and regular mail at the following addresses:

Hy-Gain Antennas

308 Industrial Park Road

Starkville, MS 39759

Telephone (800) 572-6572 or (662) 323-9538

FAX (662) 323-5803

E-Mail [email protected]

Web Page " http://www.hy-gain.com

Service history has shown that most problems are operating or installation errors, rather than equipment failures. Most problems can be resolved over the telephone. Please contact our staff before shipping parts or equipment to us.

The packing material used to ship this antenna is designed to prevent shipping damage.

Please reuse the original shipping carton if possible. Hy-Gain will not be responsible for shipping damage on returned items with improper packing.

CHART A

Band Portion

CW

CENTER

SSB

L20

41”

35”

32”

Band Portion

50-52 MHz

52-54 MHz

L6A

54 ¼”

52 ¼”

CHART B

Band

20 Meters

17 Meters

15 Meters

12 Meters

10 Meters

6 Meters

L17

163”

163”

163”

L6B

53 ¾”

51 ¾”

L15

137”

136 ¼”

135 ½”

L12

114 ½”

114 ¾”

115”

Length Adjustment

25 KHz per inch

60 KHz per ½ inch

100 KHz per ½ inch

150 KHz per ½ inch

125 KHz per ½ inch

300 KHz per ¼ inch

L10

100 ½”

99 ¾”

99”

FIGURE A

AV-620 Center Radiator Assembly

FIGURE B

AV-620 Stub Base Bracket Installation

FIGURE C

AV-620 Stub Insulator Assembly

Figure B

Stub Assembly

FIGURE F

Linear Loading Assembly

FIGURE H

Antenna Mounting Plate Assembly

hy gain®

24-MONTH LIMITED WARRANTY

hy gain

Warrants to the original owner of this product, if manufactured by

hy gain

and purchased from an authorized dealer or directly from hy

-gain

to be free from defects in material and workmanship for a period of 24 months from date of purchase provided the following terms of this warranty are satisfied.

1.

The purchaser must retain the dated proof-of-purchase (bill of sale, canceled check, credit card or money order receipt, etc.) describing the product to establish the validity of the warranty claim and submit the original or machine reproduction of such proof-of-purchase to

hy-gain

at the time of warranty service.

hy-gain

shall have the discretion to deny warranty without dated proof-of-purchase.

Any evidence of alteration, erasure, or forgery shall be cause to void any and all warranty terms immediately.

2.

hy-gain

agrees to repair or replace at

hy-gain's

option without charge to the original owner any defective product under warranty, provided the product is returned postage prepaid to

hy-gain

with a personal check, cashiers check, or money order for $8.00 covering postage and handling.

3.

Under no circumstances is

hy-gain

liable for consequential damages to person or property by the use of any

hy-gain

products.

4.

Out-of-warranty Service:

hy-gain

will repair any out-of-warranty product provided the unit is shipped prepaid. All repaired units will be shipped COD to the owner. Repair charges will be added to the COD fee unless other arrangements are made.

5.

This warranty is given in lieu of any other warranty expressed or implied.

6.

hy-gain

reserves the right to make changes or improvements in design or manufacture without incurring any obligation to install such changes upon any of the products previously manufactured.

7.

All hy-gain

products to be serviced in-warranty or out-of-warranty should be addressed to

hy-gain, 308 Industrial Park Road, Starkville, Mississippi

39759, USA

and must be accompanied by a letter describing the problem in detail along with a copy of your dated proof-of-purchase.

8. This warranty gives you specific rights, and you may also have other rights which vary from state to state.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement