SEHI-22FL

INTELLIGENT STACKABLE HUB

USER’S GUIDE

SEHI Book Page i Friday, April 19, 1996 10:46 AM

NOTICE

Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron

Systems to determine whether any such changes have been made.

The hardware, firmware, or software described in this manual is subject to change without notice.

IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL,

INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT

NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR

THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN

ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH

DAMAGES.

Copyright 1996 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005

All Rights Reserved

Printed in the United States of America

Order Number: 9031652-01 April 1996

SPECTRUM , LANVIEW , MicroMMAC , and BRIM are registered trademarks and Element

Manager , EPIM , EPIM-A , EPIM-F1 , EPIM-F2 , EPIM-F3 , EPIM-T , EPIM-X , FOT-F , FOT-F3 ,

HubSTACK , SEH , SEHI , and TMS-3 are trademarks of Cabletron Systems, Inc.

All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.

SEHI User’s Guide

Printed on Recycled Paper i

SEHI Book Page ii Friday, April 19, 1996 10:46 AM

Notice

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

DOC NOTICE

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of

Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique

édicté par le ministère des Communications du Canada.

VCCI NOTICE

This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas.

Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.

Read the instructions for correct handling.

ii SEHI User’s Guide

SEHI Book Page iii Friday, April 19, 1996 10:46 AM

Notice

CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT

IMPORTANT: Before utilizing this product, carefully read this License Agreement.

This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the

“Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME

BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND

THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT

AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED

PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.

CABLETRON SOFTWARE PROGRAM LICENSE

1.

LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.

You may not copy, reproduce or transmit any part of the Program except as permitted by the

Copyright Act of the United States or as authorized in writing by Cabletron.

2.

OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the

Program.

3.

APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.

EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY

1.

EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media).

CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO

YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING

BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND

FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE

ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.

2.

NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL

CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER

(INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,

PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL,

INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS)

ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT,

EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH

DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR

LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR

ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES, IN SOME

INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO

YOU.

SEHI User’s Guide iii

SEHI Book Page iv Friday, April 19, 1996 10:46 AM

Notice

UNITED STATES GOVERNMENT RESTRICTED RIGHTS

The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the

Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.

For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the

DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at

252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.

iv SEHI User’s Guide

SEHI Book Page v Friday, April 19, 1996 10:46 AM

CONTENTS

CHAPTER 1 INTRODUCTION

1.1

Using This Manual....................................................................... 1-1

1.2

Document Conventions ............................................................... 1-2

1.3

Getting Help................................................................................. 1-3

1.4

Related Manuals.......................................................................... 1-3

CHAPTER 2 SEHI FEATURES AND OPTIONS

2.1

SEHI Overview ............................................................................ 2-2

2.2

SEHI Features ............................................................................. 2-2

2.3

Stackable Capabilities ................................................................. 2-3

2.4

Remote Network Management Capabilities ................................ 2-3

2.5

Optional Features ........................................................................ 2-4

CHAPTER 3 INSTALLATION REQUIREMENTS AND

SPECIFICATIONS

3.1

Cable Specifications .................................................................... 3-1

3.1.1

HubSTACK Interconnect Cable Requirements............... 3-2

3.1.2

10BASE-FL Fiber Optic Network Requirements............. 3-2

3.1.3

10BASE-T UTP and STP Cable Specifications .............. 3-3

3.2

Network Port Specifications......................................................... 3-4

3.3

COM Port Requirements ............................................................. 3-5

3.4

Transceiver Requirements .......................................................... 3-5

3.5

Operating Specifications.............................................................. 3-6

3.6

Power Supply Requirements ....................................................... 3-7

3.7

Environmental Requirements ...................................................... 3-8

3.8

Agency Approvals........................................................................ 3-8

3.8.1

Safety.............................................................................. 3-8

3.8.2

Immunity ......................................................................... 3-8

3.8.3

Emission ......................................................................... 3-8

3.9

Physical Specifications ................................................................ 3-8

SEHI User’s Guide v

SEHI Book Page vi Friday, April 19, 1996 10:46 AM

Contents

CHAPTER 4 INSTALLATION

4.1

Unpacking the SEHI.....................................................................4-1

4.2

Pre-installation Test .....................................................................4-2

4.3

Installing the SEHI .......................................................................4-2

4.3.1

Tabletop or Shelf Installation...........................................4-3

4.3.2

Rackmount Installation ....................................................4-4

4.3.3

Stacking the SEHI ...........................................................4-6

4.4

Connecting the SEHI to the Power Source ..................................4-8

4.5

Adding/Replacing EPIMs .............................................................4-9

CHAPTER 5 CONNECTING TO THE NETWORK

5.1

Connecting the SEHI to the Network ...........................................5-1

5.1.1

Connecting Network Ports...............................................5-1

5.1.2

Connecting a UTP Segment to an EPIM-T .....................5-4

5.1.3

Connecting a Fiber Segment to an EPIM-F1/F2/F3 ........5-5

5.1.4

Connecting a Thin Coaxial Segment to an EPIM-C ........5-8

5.1.5

Connecting an AUI Cable to an EPIM-A .........................5-9

5.1.6

Connecting an AUI Cable to an EPIM-X .......................5-11

5.2

FInishing the Installation ............................................................5-12

CHAPTER 6 TROUBLESHOOTING

6.1

Installation CheckOut ...................................................................6-1

6.2

Using LANVIEW...........................................................................6-2

6.3

Using the RESET Button .............................................................6-4

6.4

Setting the NVRAM Switch ..........................................................6-5

CHAPTER 7 LOCAL MANAGEMENT

7.1

Local Management Keyboard Conventions .................................7-2

7.2

Management Terminal Setup.......................................................7-3

7.3

Accessing Local Management .....................................................7-6

7.4

The Feature Selection Screen .....................................................7-7

7.5

The Community Name Table Screen...........................................7-8

7.6

The Configuration Screen ..........................................................7-10

7.7

The Trap Table Screen ..............................................................7-14

7.8

The SNMP Tools Screen ...........................................................7-16

7.9

The Device Statistics Screen .....................................................7-20

vi SEHI User’s Guide

SEHI Book Page vii Friday, April 19, 1996 10:46 AM

Contents

APPENDIX A EPIM INFORMATION

A.1

EPIM Specifications.....................................................................A-1

A.1.1

EPIM-T ............................................................................A-1

A.1.2

EPIM-F1 and EPIM-F2 ....................................................A-2

A.1.3

EPIM-F3 ..........................................................................A-3

A.1.4

EPIM-C............................................................................A-4

A.1.5

EPIM-A and EPIM-X (AUI Port) ......................................A-5

APPENDIX B IMAGE FILE DOWNLOAD USING OIDs

B.1

Setting up a UNIX Workstation as a TFTP Server ......................B-2

B.2

Standard TFTP Download ...........................................................B-3

INDEX

SEHI User’s Guide vii

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

CHAPTER 1

INTRODUCTION

Welcome to the Cabletron Systems SEHI-22FL Intelligent Stackable

Hub User’s Guide . This manual provides installation instructions and reference information for the SEHI-22FL.

NOTE

The term SEHI (Stackable Ethernet Hub with Intelligence) is used throughout this manual when describing the features and functions of the SEHI-22FL.

1.1

USING THIS MANUAL

Read through this manual to gain an understanding of the features and capabilities of the SEHI. A general knowledge of Ethernet and IEEE

802.3 type data communications networks and their physical layer components is helpful when installing the SEHI.

Chapter 1, Introduction , outlines the contents of this manual, describes

document conventions, provides getting help information and concludes with a list of related manuals.

Chapter 2, SEHI Features and Options , details the features of the SEHI

and provides information about available options including EPIMs

(Ethernet Port Interface Modules) and HubSTACK interconnect cables.

Chapter 3, Installation Requirements and Specifications , describes

installation requirements, network guidelines, and SEHI operating specifications.

Chapter 4, Installation , contains instructions for installing the SEHI as a

stackable or standalone hub.

Chapter 5, Connecting to the Network , explains how to connect the

SEHI to the network using the various media types.

Chapter 6, Troubleshooting , describes how to use the LANVIEW LEDs

to troubleshoot network problems.

SEHI User’s Guide 1-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Chapter 1: Introduction

Chapter 7, Local Management , describes how to use SEHI Local

Management screens and the available commands.

Appendix A, EPIM Information , provides specifications, cabling

information, and switch settings for the Ethernet Port Interface Modules.

Appendix B, Image File Download Using OIDs , provides instructions

for setting up a TFTP server and downloading image files to the SEHI by setting specific MIB OID strings.

1.2

DOCUMENT CONVENTIONS

The following conventions are used throughout this document:

NOTE

Note symbol. Calls the reader’s attention to any item of information that may be of special importance.

TIP

Tip symbol. Conveys helpful hints concerning procedures or actions.

!

C AUT IO N

Caution symbol. Contains information essential to avoid damage to the equipment.

Warning symbol. Warns against an action that could result in equipment damage, personal injury or death.

1-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Getting Help

1.3 GETTING HELP

If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact

Cabletron Systems Technical Support:

By phone

By CompuServe

By Internet mail

By FTP

Login

Password

(603) 332-9400

Monday – Friday; 8

A

.

M

. – 8

P

.

M

. Eastern Time

GO CTRON from any ! prompt [email protected]

ctron.com (134.141.197.25) anonymous your email address

Before calling Cabletron Systems Technical Support, have the following information ready:

• A description of the failure

• A description of any action(s) already taken to resolve the problem

(e.g., changing mode switches, rebooting the unit, etc.)

• A description of your network environment (layout, cable type, etc.)

• Network load and frame size at the time of trouble (if known)

• The serial and revision numbers of all Cabletron Systems products in the network

• The device history (i.e., have you returned the device before, is this a recurring problem, etc.)

• Any previous Return Material Authorization (RMA) numbers

1.4

RELATED MANUALS

Use the Cabletron Systems SEH-22FL Stackable Hub User’s Guide to supplement the procedures and other technical data provided in this manual. The procedures contained in the SEH-22FL Stackable Hub

User’s Guide are referenced where appropriate, but not repeated in this manual.

SEHI User’s Guide 1-3

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

CHAPTER 2

SEHI FEATURES AND OPTIONS

This chapter provides an overview of the SEHI-22FL and contains sections detailing features and available options.

NOTE

The term SEHI (Stackable Ethernet Hub with Intelligence) is used throughout this manual when describing features and functions of the SEHI-22FL.

FRONT VIEW

HubSTACK

10BASE-FL HUB

WITH

LANVIEW®

SECURE

SEHI-22FL

RESET

COM

PWR

CPU

CLN

RCV

LNK

12 11 10 9 8 7 6 5 4 3 2 1

E

1

RX TX RX TX RX TX RX TX RX TX RX TX

12

RX TX

11

RX TX

10 9 8

RX TX RX TX RX TX

7

RX TX

6 5 4 3 2 1

Port Status LEDs

System LEDs

COM Port

RESET Button

Network Ports 1-12

EPIM Slot

EPIM 1

SEHI-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT

Power Supply

ON/OFF Switch

Interconnect Bus "OUT" Port

REAR VIEW

Figure 2-1 Front and Rear Views of the SEHI-22FL

SEHI User’s Guide 2-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Chapter 2: SEHI Features and Options

2.1

SEHI OVERVIEW

The SEHI-22FL is an intelligent repeating hub providing front panel ports for network connections and a rear panel HubSTACK Interconnect Bus port for stackable connections. The SEHI is designed to manage the

Cabletron Systems SEH series of non-intelligent stackable hubs.

The SEHI-22FL provides twelve 10BASE-FL ST-type fiber optic ports and one EPIM (Ethernet Port Interface Module) port.

2.2

SEHI FEATURES

This section provides detailed information about SEHI features and capabilities.

Repeater Functionality

The SEHI fully conforms to the IEEE 802.3 10BASE-FL specifications, and provides the flexibility to connect networks using IEEE 802.3,

Ethernet Version 1 or Version 2 equipment. The SEHI transmits retimed data packets, regenerates the preamble, extends fragments, and arbitrates collisions.

The SEHI automatically partitions problem segments, and reconnects repaired segments to the network. This feature minimizes the impact on network operation resulting from a problem on one segment by isolating the problem segment. Only devices on the problem segment are affected.

When the problem is solved, the SEHI automatically reconnects the isolated segment to the network.

FLASH EEPROMs

The SEHI uses FLASH EEPROMs that allow the downloading of new and updated firmware using Cabletron Systems SPECTRUM Element

Manager/Windows or any device using BOOTP or TFTP protocols.

LANVIEW LEDs

Cabletron Systems LANVIEW Status Monitoring and Diagnostics

System is a troubleshooting tool that helps in diagnosing power failures, collisions, cable faults, and link problems. The LANVIEW LEDs are conveniently located on the SEHI front panel.

2-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Stackable Capabilities

RESET Button

Resetting the hub with the front panel RESET button reboots the SEHI and initializes the processor.

Local Management

Manage the SEHI and attached segments through Local Management on the SEHI. Local Management provides full packet and error statistics for the entire stack, individual device, or individual port. Access Local

Management by attaching a DEC VT320 terminal or a PC using VT320 emulation software to the SEHI RJ45 COM port.

2.3

STACKABLE CAPABILITIES

The SEHI intelligent hub is designed to manage the Cabletron Systems series of SEH non-intelligent hubs. The SEHI serves as the logical “top” of the stack. It manages all SEH hubs in the stack providing full packet and error statistics for the entire stack, individual device, or individual port.

Stack up to four SEH non-intelligent hubs with one SEHI using Cabletron

Systems external HubSTACK Interconnect cables. Stackable configurations make it possible to maintain only one IEEE repeater hop while providing up to 130 10BASE-T Ethernet ports. Add or remove hubs from the stack without powering down.

2.4

REMOTE NETWORK MANAGEMENT

CAPABILITIES

Manage the SEHI remotely with any SNMP network management system. Cabletron Systems offers the following remote management packages:

• Cabletron Systems SPECTRUM

• Cabletron Systems SPECTRUM Element Manager/Windows

• Cabletron Systems Remote SPECTRUM Portable Management

Applications

• Third Party SNMP compliant Network Management Packages

SEHI User’s Guide 2-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Chapter 2: SEHI Features and Options

2.5

OPTIONAL FEATURES

The following features are not included with the SEHI, but are purchased separately from Cabletron Systems.

Ethernet Port Interface Modules (EPIMs)

EPIMs enable the expansion of the network through a variety of media.

Cabletron Systems offers the EPIMs shown in Table 2-1.

Table 2-1 EPIMs

EPIM-A

EPIM-C

EPIM-T

EPIM-X

EPIM-F1

EPIM-F2

EPIM-F3

AUI

10BASE2 Thin Coaxial

10BASE-T Unshielded Twisted

Pair

Standard Transceiver

Multimode Fiber

Multimode Fiber

Single Mode Fiber

Connector

DB15 (Female)

BNC

RJ45

DB15 (Male)

SMA

ST

ST

HubSTACK Interconnect Cables

Stack hubs together with Cabletron Systems HubSTACK Interconnect

cables. Table 2-2 lists the part number and the application for each cable.

P/N

9380110

9380111

Table 2-2 HubSTACK Interconnect Cables

Application Description

12" HubSTACK

Interconnect Cable

18" HubSTACK

Interconnect Cable

SEH to SEH connections.

SEHI to SEH connections.

Rack Mount Hardware

The SEHI can be installed in a 19-inch rack. Cabletron offers an accessory package that includes brackets and mounting screws. The part number for the accessory package is SEHI-ACCY-KIT.

2-4 SEHI User’s Guide

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

CHAPTER 3

INSTALLATION REQUIREMENTS AND

SPECIFICATIONS

This chapter describes cabling requirements, network guidelines, and operating specifications for the SEHI.

!

C AUT IO N

The network must meet the requirements and conditions specified in this chapter to obtain satisfactory performance from this equipment. Failure to follow these guidelines can result in poor network performance.

The network must meet the requirements and conditions specified in this chapter to obtain satisfactory performance from this equipment. Failure to follow these guidelines can result in poor network performance.

3.1

CABLE SPECIFICATIONS

The SEHI-22FL network ports support 10BASE-FL Multimode Fiber

Optic cabling.

Ethernet Port Interface Modules (EPIMs) expand a network using

Unshielded Twisted Pair (UTP), Shielded Twisted Pair (STP), Multimode

Fiber Optic, Single Mode Fiber Optic, or Thin Coaxial cabling. For

information concerning EPIMs, refer to Appendix A.

The rear panel Interconnect Bus port supports Cabletron Systems

HubSTACK Interconnect cables for stackable applications.

Take care in planning and preparing the network cabling and connections.

The quality of the connections and the length of cables are critical factors in determining the reliability of the network. The following sections provide the specifications for each media type.

SEHI User’s Guide 3-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Chapter 3: Installation Requirements and Specifications

3.1.1

HubSTACK Interconnect Cable Requirements

Attach the SEHI to modules in the stack with the SEHI HubSTACK

Interconnect cable available only from Cabletron Systems. Refer to

Chapter 1 for cable part numbers. The cable attaches to the SEHI rear panel bus port.

The rear panel of the SEHI has an Interconnect Bus Out port (male connector) to stack SEH non-intelligent hubs together. Stack up to four

SEH hubs together with one SEHI.

3.1.2

10BASE-FL Fiber Optic Network Requirements

Table 3-1 shows Multimode Fiber Optic Cable specifications for the

SEHI-22FL.

Table 3-1 Multimode Fiber Optic Cable Specifications

Cable Type

50/125

µ m

62.5/125

µ m

100/140

µ m

Attenuation

13.0 dB or less

16.0 dB or less

19.0 dB or less

Maximum Cable Length

Maximum fiber optic cable length is 2 km (2187.2 yds). However, IEEE 802.3 specifications allow for a maximum of 1 km (1093.6 yds).

Attenuation

Test the fiber optic cable with a fiber optic attenuation test set adjusted for an 850 nm wavelength. This test verifies that the signal loss in a cable is

within an acceptable level. Table 3-1 shows the attenuation for each

Multimode cable type.

Fiber Optic Budget and Propagation Delay

Determine the maximum fiber optic cable length by calculating the fiber optic budget delay and total network propagation before the fiber optic cable runs are incorporated into a network design.

Fiber optic budget is the combination of the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors.

Propagation delay is the amount of time it takes data to travel from the sending device to the receiving device. Total propagation delay allowed for the network is 25.6

µ s (51.2

µ s roundtrip). If the total propagation delay between any two nodes on the network exceeds 25.6

µ s, then use bridges.

3-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Cable Specifications

3.1.3

10BASE-T UTP and STP Cable Specifications

The devices and 10BASE-T Twisted Pair Segments connected to an SEHI

EPIM-T module must meet the IEEE 802.3 10BASE-T specifications shown below:

Length

The IEEE 802.3 10BASE-T standard requires that 10BASE-T devices transmit over a 100 meter (328 foot) link using 22-24 AWG Unshielded

Twisted Pair (UTP) wire. However, cable quality largely determines the maximum link length. With high quality, low attenuation cable, link lengths of up to 200 meters are achievable. Cable delay limits the maximum link length to 200 meters, regardless of the cable type.

Insertion Loss

The maximum insertion loss allowed for a 10BASE-T link is 11.5 dB at all frequencies between 5.0 and 10 MHz. This includes the attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the link segment.

Impedance

Cabletron Systems 10BASE-T Twisted Pair products work on twisted pair cable with 75 to 165 ohms impedance. UTP cables typically have an impedance of 85 to 110 ohms.

Shielded Twisted Pair (STP) cables, such as IBM Type 1 cable, are also used. The impedance of IBM Type 1 cable is typically 150 ohms. Higher impedance increases signal reflection, but because the cable is shielded, signal reflection has little effect on the quality of the received signal due to the lack of crosstalk between the shielded cable pairs.

Jitter

Intersymbol interference and reflections cause jitter in the bit cell timing, resulting in data errors. A 10BASE-T link must not generate more than

5.0 ns of jitter. If the cable meets the impedance requirements for a

10BASE-T link, jitter should not be a concern.

Delay

The maximum propagation delay of a 10BASE-T link segment must not exceed 1000 ns. This 1000 ns maximum delay limits the maximum link segment length to no greater than 200 meters.

SEHI User’s Guide 3-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Chapter 3: Installation Requirements and Specifications

Crosstalk

Crosstalk is caused by signal coupling between the different cable pairs contained within a multi-pair cable bundle. 10BASE-T transceivers are designed so that the user does not need to be concerned about cable crosstalk, provided the cable meets all other requirements.

Noise

Noise is caused by either crosstalk or externally induced impulses.

Impulse noise may cause data errors if the impulses occur at very specific times during data transmission. Generally, the user need not be concerned about noise. If noise-related data errors are suspected, it may be necessary to either reroute the cable or eliminate the source of the impulse noise.

Temperature

Multi-pair PVC 24 AWG cables typically have an attenuation of

8 dB to 10 dB/100 meters at 20

°

C (68

°

F). The attenuation of PVC insulated cable varies significantly with temperature. At temperatures greater than 40

°

C (104

°

F), Cabletron Systems recommends the use of plenum-rated cables to ensure that cable attenuation remains within specification.

3.2

NETWORK PORT SPECIFICATIONS

The SEHI-22FL provides ST-type ports for 10BASE-FL Multimode Fiber

Optic cabling. Figure 3-1 shows the network ports.

RX TX RX TX RX TX RX TX RX TX RX TX

12 11

RX TX RX TX

10 9 8

RX TX RX TX RX TX

7

RX TX

6 5 4 3 2 1

09162_04

Figure 3-1 SEHI-22FL Network Ports

3-4 SEHI User’s Guide

SEHI Book Page 5 Friday, April 19, 1996 10:46 AM

COM Port Requirements

3.3

COM PORT REQUIREMENTS

The RJ45 COM port supports access to a Local Management Console.

The Console port supports a Digital Equipment Corporation, VT320

terminal or PC emulation of the VT320 terminal. Figure 3-2 shows the

pinouts for the RJ45 COM port.

1 2 3 4 5 6 7 8

1. Transmit Data

2. Data Carrier Detect

3. Data Set Ready

4. Receive Data

COM

165201

5. Signal Ground

6. Data Terminal Ready

7. Request To Send

8. Clear To Send

Figure 3-2 COM Port Pinouts

3.4

TRANSCEIVER REQUIREMENTS

When connecting an external network segment through a transceiver to the SEHI with an EPIM-A, the following requirements must be met:

• The transceiver or Ethernet device to which the module is connected must meet IEEE 802.3 standards, and/or Ethernet Version 1.0 or

Version 2.0 standards.

• The Signal Quality Error (SQE) test function on the transceiver must be disabled when it is connected to a repeater or to an Ethernet Version

1.0 device. In addition, some Version 2.0 equipment does not support the SQE test. Devices that do not support the SQE test interpret the

SQE test pulse as a collision.

SEHI User’s Guide 3-5

SEHI Book Page 6 Friday, April 19, 1996 10:46 AM

Chapter 3: Installation Requirements and Specifications

3.5

OPERATING SPECIFICATIONS

The operating specifications for the SEHI are described in this section.

Cabletron Systems reserves the right to change these specifications at any time without notice.

System Specifications

Operating System Memory:

Internal Processor:

Ethernet Controller:

Non-Volatile RAM:

EPROM:

FLASH MEMORY:

1.5 MB

Intel i960 operating at 16 MHz

National Semiconductor DP83916

32 KB with battery back-up

64 KB

1 MB

Delay Time (Start of Packets) Specifications

Twisted Pair to EPIM-A: 1.10 ms

Twisted Pair to Twisted Pair:

EPIM-A to Twisted Pair:

1.00 ms

1.00 ms

Delay Times (JAM) Specifications

Twisted Pair to EPIM-A: 960 ns

Preamble Specifications

Input:

Output:

Minimum of 40 bits required

64 bits min. (last 2 bits are 1,1)

3-6 SEHI User’s Guide

SEHI Book Page 7 Friday, April 19, 1996 10:46 AM

Power Supply Requirements

JAM Output Specifications

Collisions are propagated through the network using the JAM signal of an alternating pattern of 1’s and 0’s in accordance with 802.3 specifications for a repeater unit.

Fragment Extension Specifications

Fragments are extended to a minimum of 96 bits using the JAM [1,0].

Fault Protection Specifications

Each segment disconnects itself from the other segments if 32 consecutive collisions occur, or if the collision detector of a segment is on for longer than approximately 110

µ s. This fault protection resets automatically after one packet is transmitted/received onto the fault protected segment without causing a collision.

3.6

POWER SUPPLY REQUIREMENTS

The SEHI has a universal power supply. The input power requirements

are listed in Table 3-2.

Model

SEHI-22FL

Table 3-2 Power Requirements

Frequency Range Voltage Range

100–125 Vac or 200–250 Vac

50/60 Hz

The power supply has two outputs of +5 Vdc and +12 Vdc. The maximum output power is 40 W and the minimum efficiency is 65% under all conditions of the line at full load. The minimum and maximum load

currents from each output are listed in Table 3-3.

Output

+5 Vdc

+12 Vdc

Table 3-3 Power Supply Output Specifications

Min. Load

0.75 A

0.00 A

Max. Load

4 A

2 A

Max Power

20 W

24 W

SEHI User’s Guide 3-7

SEHI Book Page 8 Friday, April 19, 1996 10:46 AM

Chapter 3: Installation Requirements and Specifications

3.7

ENVIRONMENTAL REQUIREMENTS

The environmental requirements for the SEHI are detailed in this section.

Operating Temperature: 5

°

C to 40

°

C (41

°

F to 104

°

F)

Storage Temperature: -30

°

C to 90

°

C (-22

°

F to 194

°

F)

Operating Humidity: 5% to 95% (non-condensing)

3.8

AGENCY APPROVALS

The Safety, Immunity, and Emission approvals for the SEHI are detailed in this section.

3.8.1

Safety

This unit meets the safety requirements of UL 1950, CSA C22.2 No. 950,

IEC 950, and EN 60950.

3.8.2

Immunity

This unit meets the immunity requirements of EN 50082-1 including

IEC 801-2 (ESD), IEC 801-3 (Radiated Susceptibility), and IEC 801-4 (EFT/B).

3.8.3

Emission

This unit meets the emission requirements of FCC Part 15 Class A,

EN 55022 Class A, and VCCI Class I.

3.9

PHYSICAL SPECIFICATIONS

This section details the physical specifications for the SEHI.

Dimensions (H x W x D):

Weight (Unit):

(7.2 cm x 43.6 cm x 34.6 cm)

(2.8 in x 17.0 in x 13.5 in)

3 kg (6.5 lb)

3-8 SEHI User’s Guide

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

CHAPTER 4

INSTALLATION

This chapter outlines the procedure for attaching the SEHI to the network as a stackable or standalone device. Ensure that the network meets the

guidelines and requirements outlined in Chapter 3, Installation

Requirements and Specifications, before installing the SEHI.

Failure to follow installation instructions may result in an electrical shock hazard.

4.1

UNPACKING THE SEHI

Unpack the SEHI as follows:

1. Remove the shipping material covering the SEHI in the shipping box.

2. Carefully remove the SEHI from the shipping box and set it aside to prevent damage.

3. Visually inspect the SEHI. If there are any signs of damage, contact

Cabletron Systems Technical Support immediately.

4. Read the SEHI Release Notes included in the shipping box.

NOTE

Cabletron Systems includes a 3-1/2" disk with the SEHI that contains a backup copy of the SEHI Flash Firmware Image

File. Download the file to the SEHI if the existing image becomes corrupted.

SEHI User’s Guide 4-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Chapter 4: Installation

4.2

PRE-INSTALLATION TEST

The SEHI is equipped with an NVRAM reset switch (Figure 4-1) located

behind the grillwork on the side of the hub. Ensure that this switch is in the DOWN position by looking in through the grillwork on the right side of the hub. If the switch is UP, move it into the DOWN position with a

non-metallic tool. Do not remove the chassis cover to perform this operation. Leaving the switch in the UP position results in user-installed parameters such as IP address and Community Names being cleared from

NVRAM whenever the SEHI loses power and/or is reset. See Chapter 6,

Section 6.4, for detailed instructions on setting the NVRAM switch.

Rear of Chassis

NVRAM Switch located behind grating

09162_05

Figure 4-1 NVRAM Switch Location

4.3

INSTALLING THE SEHI

The SEHI may be installed on a tabletop or shelf, or in a 19-inch rack, and configured as a standalone or stacked hub.

Refer to Section 4.3.1 for information concerning a tabletop or shelf

installation. Section 4.3.2 describes the rackmount installation.

4-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Installing the SEHI

4.3.1

Tabletop or Shelf Installation

This section provides guidelines for installation on a tabletop or shelf.

Tabletop and shelf installations must be within reach of the network cabling and meet the requirements listed below:

• A single phase grounded power receptacle that meets the power supply

requirements listed in Chapter 3 under Power Supply Requirements

must be located within seven feet of the location.

• In a shelf installation, the shelf must be able to support 30 pounds of static weight for each device in the stack.

• Maintain a temperature of between 5

°

C (41

°

F) and 40

°

C (104

°

F) at the site with fluctuations of less than 10

°

C (18

°

F) per hour.

For a tabletop or shelf installation, locate the SEHI within seven feet of its power source and with an unrestricted free surface area as shown in

Figure 4-2.

!

C AUT IO N

In order to allow for proper cooling, there must be a two-inch clearance on either side and the back of the unit.

6 IN.

18 IN.

21 IN.

HubSTACK

SEHI-22FL

WITH LANVIEW® SECURE

RESET

COM

PWR

CPU

CLN

RCV

LNK

12 11 10 9 8 7 6 5 4 3 2 1

E

1

RX TX RX TX RX TX RX TX RX TX RX TX

RX

12

TX RX

11

TX RX

10

TX RX

9

TX RX

8

TX

6 5 4 3 2

RX

7

TX

1 EPIM 1

7 FT

0165203

Figure 4-2 Tabletop or Shelf Installation

If the installation requires that the SEHI is to be stacked, proceed to

Section 4.3.3. Otherwise, continue by connecting power as described in

Section 4.4.

SEHI User’s Guide 4-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Chapter 4: Installation

4.3.2

Rackmount Installation

To install the SEHI in a 19-inch rack, Cabletron Systems offers an accessory kit that includes rackmount brackets, mounting screws, and a strain-relief bracket for cable management. The accessory kit is not included with the SEHI, but can be purchased separately from Cabletron

Systems using the part number SEHI-ACCY-KIT.

Rack mounting the SEHI involves the following:

• Attaching the strain-relief bracket

• Rack mounting the SEHI

• Stacking the SEHI when applicable

Attaching the Strain-Relief Bracket

Attach the strain-relief bracket to the front of the SEHI as follows:

1. Locate the strain-relief bracket and four 8-32 x 3/8 inch screws from the SEHI-ACCY-KIT package.

Do NOT attempt to attach the strain-relief with screws other than the 8-32 x 3/8-inch screws included with the SEHI accessory kit. Use of longer screws may damage the unit or cause electrical shock.

2. Attach the strain-relief bracket to the bottom of the SEHI (Figure 4-3).

Screws (4)

Strain-Relief Bracket

4-4

EPIM 1

12 11

LNK

RCV

CPU

PWR

CLN

COM

TX

1

TX

7

RX

RX TX

2

TX

8

RX

RX TX

3

TX

9

RX

RX TX

10

TX RX

4

RX TX

11

TX RX

5

RX TX

12

TX RX

6

RX

1

E

10 9 8 7 6 5 4 3 2 1

RESET

SEHI-22FL

SECURE WITH LANVIEW® 10BASE-FL HUB HubSTACK

Figure 4-3 Attaching the Strain-Relief Bracket

SEHI User’s Guide

SEHI Book Page 5 Friday, April 19, 1996 10:46 AM

Installing the SEHI

Rack Mounting the SEHI

Refer to Figure 4-4 and proceed as follows to install the SEHI into a

19-inch rack.

1. Remove four cover screws (two from each side) located along the front edges of each side of the SEHI.

Do not remove the cover from the SEHI. Do not remove any other screws from the unit.

2. Using the four 6-32 x 3/8-inch replacement flathead cover screws provided in the SEHI-ACCY-KIT, attach the rack mounting brackets to each side of the SEHI.

Rack Mounting

Brackets (2)

HubSTACK 10BASE-FL HUB

WITH

LANVIEW®

SECURE

SEHI-22FL

RESET

COM

PWR

CPU

CLN

RCV

LNK

12 11 10 9 8 7 6 5 4 3 2 1

E

1

RX TX RX TX RX

TX

RX TX RX TX RX TX

RX

12

TX RX

11

TX RX

10

TX

RX

9

TX RX

8

TX RX

7

TX

6 5 4 3 2 1 EPIM 1

0165205

Screws (4)

Figure 4-4 Installing the Rack Mounting Brackets

3. Ensure that the rack used will support the unit and that the rack will remain stable with the unit installed in it. Support the SEH securely from underneath and align the brackets of the SEH chassis with the

screw holes in the equipment rack as shown in Figure 4-5. Fasten the

SEH to the equipment rack securely.

SEHI User’s Guide 4-5

SEHI Book Page 6 Friday, April 19, 1996 10:46 AM

Chapter 4: Installation

!

C AUT IO N

The cooling fans at the rear panel of the SEHI must have adequate clearance ( two inches on either side and in the rear ) for unrestricted air flow. The temperature for the selected location must be maintained between 5

°

C and 40

°

C, and fluctuate less than 10

°

C per hour.

19-Inch Rack

HubSTACK 10BASE-FL HUB

WITH

LANVIEW®

SECURE

SEHI-22FL

RESET

COM

PWR

CPU

CLN

RCV

LNK

12 11 10 9 8 7 6 5 4 3 2 1

E

1

RX TX RX TX RX TX RX TX RX TX RX TX

RX

12

TX

6

11

RX TX

5

RX

10

TX RX

9

TX

4 3

RX

8

TX

2

RX

7

TX

1

EPIM 1

Screws (4)

0165206

Figure 4-5 Installing the SEHI in the Rack

If the installation requires stacking the SEHI, proceed to Section 4.3.3.

Otherwise, continue by connecting power as described in Section 4.4.

4.3.3

Stacking the SEHI

The rear panel of the SEHI has an Interconnect Bus Out Port (male connector). Daisy chain units together using Cabletron Systems

HubSTACK Interconnect cables. Table 4-1 describes each cable.

Table 4-1 HubSTACK Interconnect Cables

Part

Number

9380110

9380111

Description

12" HubSTACK Interconnect Cable

18" HubSTACK Interconnect Cable

Application

SEH to SEH

SEHI to SEH

4-6 SEHI User’s Guide

SEHI Book Page 7 Friday, April 19, 1996 10:46 AM

Installing the SEHI

To stack the SEHI together with an SEH non-intelligent hub, proceed as follows:

1. Attach the SEHI HubSTACK Interconnect cable to the “OUT” port on

the rear panel of the SEHI as shown in Figure 4-6.

2. Attach the other end of the SEHI HubSTACK Interconnect cable to the “IN” port on the rear panel of the SEH.

To stack SEH non-intelligent hubs together, proceed as follows:

1. Attach the SEH HubSTACK Interconnect cable to the “OUT” port on

the rear panel of the SEH as shown in Figure 4-6.

2. Attach the other end of the SEH HubSTACK Interconnect cable to the

“IN” port on the rear panel of the SEH next in the stack.

SEH HubSTACK

Interconnect Cables

SEH-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT IN

SEH-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT

IN

SEH-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT IN

SEH-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT IN

SEHI-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT

SEHI HubSTACK

Interconnect Cable

Figure 4-6 Stacking the SEHI

165210

SEHI User’s Guide 4-7

SEHI Book Page 8 Friday, April 19, 1996 10:46 AM

Chapter 4: Installation

If one end of a HubSTACK Interconnect cable is disconnected without disconnecting the other end attached to the hub, disconnect the cable from

the OUT port as shown in Figure 4-7 to ensure that the HubSTACK

Interconnect cable is terminated properly.

Disconnect SEH and SEHI

Interconnect Cables at the "OUT" Port

SEH-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT IN

SEH-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT IN

SEHI-22FL

100BASE-FL HUB WITH LANVIEW®

OUT SEH INTERCONNECT

165211

Figure 4-7 Disconnecting the HubSTACK Interconnect Cable

Proceed to Section 4.4 to connect power.

4.4

CONNECTING THE SEHI TO THE POWER SOURCE

NOTE

The SEHI uses a universal power supply that operates between 100–125 Vac or 200–250 Vac, 50/60 Hz.

Connect the SEHI to the power source as follows:

1. Plug the power cord into the back panel of the SEHI.

2. Plug the other end of the power cord into a grounded wall outlet.

3. Verify that the PWR LED is on, indicating that the SEHI is receiving power. After the SEHI runs a self test, the CPU LED blinks green indicating normal operation. If the LED remains red, the processor is faulty, contact Cabletron Systems Technical Support.

4-8 SEHI User’s Guide

SEHI Book Page 9 Friday, April 19, 1996 10:46 AM

Adding/Replacing EPIMs

4.5

ADDING/REPLACING EPIMS

This section contains procedures on how to add or replace an Ethernet

Port Interface Module (EPIM) to upgrade or change the capabilities of your SEHI. After installing a new EPIM, refer to the appropriate EPIM section in Appendix A to verify proper operation.

!

C AUT IO N

Observe all static precautions while handling EPIMs.

Perform the following steps to install an EPIM:

NOTE

When removing an EPIM, pull the module out straight to prevent damage to the connector.

1. Remove the coverplate or the EPIM (whichever applies).

2. Slide the new EPIM into place, making sure that the connectors on the rear of the EPIM align correctly and firmly with the connector inside

the SEHI. See Figure 4-8.

3. Tighten the mounting screw.

TX

RX TX

RX TX

RX TX

RX TX

10

RX TX

9

RX TX

8

RX TX

7

4

3

2

1

165202

EPIM-1

Figure 4-8 Installing an EPIM

PWR

EPIM-A

SEHI User’s Guide 4-9

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

CHAPTER 5

CONNECTING TO THE NETWORK

This chapter outlines the procedure for connecting the SEHI to a network.

Ensure that the network meets the guidelines and requirements outlined in

Chapter 3, Installation Requirements and Specifications, before

installing the SEHI.

5.1

CONNECTING THE SEHI TO THE NETWORK

The procedure for connecting network segments to the SEHI varies depending on the media and ports being connected. Refer to the following list and perform the procedure described in the subsections that apply to connecting the SEHI to a network:

• Connecting Network Ports

• Connecting a UTP segment to an EPIM-T

Section 5.1.1

Section 5.1.2

• Connecting a fiber segment to an EPIM-F1/F2/F3

Section 5.1.3

• Connecting a Thin Coaxial Segment to an EPIM-C

Section 5.1.4

• Connecting an AUI cable to an EPIM-A

• Connecting an AUI Cable to an EPIM-X

Section 5.1.5

Section 5.1.6

5.1.1

Connecting Network Ports

The SEHI-22FL has ST style network ports. Read the following guidelines before connecting a fiber optic link segment to the SEHI:

• Insert the connector into the port with the alignment key on the connector inserted into the alignment slot on the port. The connector is then turned clockwise to lock it down.

• The physical communication link consists of two strands of fiber optic cabling: the Transmit (TX) and the Receive (RX). Connect the TX strand from the applicable port on the module to the receive port of a fiber optic Ethernet device at the other end of the segment. The RX strand of the applicable port on the module connects to the transmit port of the fiber optic Ethernet device.

SEHI User’s Guide 5-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Chapter 5: Connecting to the Network

• Label the fiber optic cable to indicate which fiber is receive and which is transmit. Cabletron Systems fiber optic cable is labeled so that one fiber is labeled 1, and the other fiber is labeled 2 at both ends of the cable. If the cable was not purchased from Cabletron Systems, label the cable as described above.

!

C AUT IO N

Do not touch the ends of the fiber optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants.

Contamination of the ends causes problems in data transmissions. If the ends become contaminated, clean them with alcohol using a soft, clean, lint-free cloth.

Use the following steps to connect a fiber optic link segment to the SEHI:

1. Remove the protective plastic covers from the fiber optic ports on the applicable port on the module and from the ends of the connectors on each fiber strand.

2. Attach the fiber labeled 1 to the applicable RX port, on the SEHI. See

Figure 5-1.

RX

TX

RX

TX

RX

TX

12

RX

TX

11

RX

5

4

3

2

RX

TX

RX

TX

RX

TX

TX

10

RX

RX

TX

TX

9

RX

TX

8

RX

TX

7

1

6

09032_09

Figure 5-1 SEHI-22FL Network Ports

1

2

5-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Connecting the SEHI to the Network

3. Attach the fiber labeled 2 to the applicable TX port, on the SEHI.

4. At the other end of the fiber optic cable, attach the fiber labeled 1 to the transmit port of the device.

5. Attach the fiber labeled 2 to the receive port.

6. Check that the LNK LED for the appropriate port is on. If the LED is off, perform the following steps until it is on: a.

Check that the power is turned on for the device at the other end of the link.

b. Verify proper crossover of fiber strands between the applicable port on the SEHI and the fiber optic device at the other end of the fiber optic link segment.

c.

Verify that the fiber connection meets the dB loss specifications

outlined in Chapter 3.

If a link is not established, contact Cabletron Systems Technical Support.

SEHI User’s Guide 5-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Chapter 5: Connecting to the Network

5.1.2

Connecting a UTP Segment to an EPIM-T

Before connecting a segment to the EPIM-T, check each end of the segment to determine if the wires cross over for proper connection. If the wires do not cross over, use the switch on the EPIM-T to internally cross

over the RJ45 port. Figure 5-2 shows the pin assignment of the port

according to the switch position.

Position X

(crossed over)

1. RX+

2. RX-

3. TX+

4. NC

5. NC

6. TX-

7. NC

8. NC

Position =

(not crossed over)

1. TX+

2. TX-

3. RX+

4. NC

5. NC

6. RX-

7. NC

8. NC

Figure 5-2 EPIM-T Crossover Switch

1490_14

To connect an EPIM-T to a twisted pair segment:

1. Connect the segment to the module by inserting the RJ45 connector on

the segment into the RJ45 port on the module. See Figure 5-2.

2. Check that the EPIM LNK LED is on. If the LED is off, perform each of the following steps until it is on: a.

Check that the device at the end of the segment is powered up.

b. Verify that the RJ45 connector on the twisted pair segment has the proper pinouts.

c.

Check the cable for continuity.

d. Check that the twisted pair connection meets dB loss and cable

specifications outlined in Chapter 3, Section 3.1.3.

e.

Check that the crossover switch is in the correct position.

5-4 SEHI User’s Guide

SEHI Book Page 5 Friday, April 19, 1996 10:46 AM

Connecting the SEHI to the Network

If a link is not established, contact Cabletron Systems Technical Support.

5.1.3

Connecting a Fiber Segment to an EPIM-F1/F2/F3

When connecting a fiber optic link segment to an EPIM-F1, F2, or F3 keep the following in mind:

• When connecting a fiber optic link segment with SMA 906 connectors to an EPIM-F1 with SMA ports, ensure that the half alignment sleeves

(shown in Figure 5-3) are in place on each connector. A full alignment

sleeve will damage the receive port. SMA 905 connectors do not need alignment sleeves.

• Connect a segment with ST connectors to an EPIM-F2 or EPIM-F3 by inserting the connector into the port with the alignment key on the connector inserted into the alignment slot on the port. Turn the connector clockwise to lock it down.

• The physical communication link consists of two strands of fiber optic cabling: the Transmit (TX) and the Receive (RX). The TX strand from the applicable port on the module connects to the receive port of a fiber optic Ethernet device at the other end of the segment. The RX strand of the applicable port on the module connects to the transmit port of the fiber optic Ethernet device.

• Label the fiber optic cable to indicate which fiber is receive and which is transmit. Fiber optic cable purchased from Cabletron Systems is labeled so that one fiber is labeled 1, and the other fiber is labeled 2 at both ends of the cable. For cable not purchased from Cabletron

Systems, label the cable as described above.

!

C AUT IO N

Do not touch the ends of the fiber optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants.

Contamination of the ends causes problems in data transmissions. If the ends become contaminated, clean them with alcohol using a soft, clean, lint free cloth.

SEHI User’s Guide 5-5

SEHI Book Page 6 Friday, April 19, 1996 10:46 AM

Chapter 5: Connecting to the Network

Connect a fiber optic link segment to an EPIM-F1, EPIM-F2, or an

EPIM-F3 as follows:

1. Remove the protective plastic covers from the fiber optic ports on the applicable port on the module and from the ends of the connectors on each fiber strand.

2. Attach the fiber labeled 1 to the applicable RX port on the module. See

Figure 5-3.

3. Attach the fiber labeled 2 to the applicable TX port on the module.

4. At the other end of the fiber optic cable, attach the fiber labeled 1 to the transmit port of the device.

5. Attach the fiber labeled 2 to the receive port.

6. Check that the EPIM LNK LED is on. If the LED is off, perform the following steps until it is on: a.

Check that the power is on for the device at the end of the link.

b. Verify that the fiber strands are properly crossed over between the applicable port on the module and the fiber optic device at the other end of the fiber optic link segment.

c.

Verify that the fiber connection meets the dB loss specifications outlined in fiber optic network requirements.

If a link is not established, contact Cabletron Systems Technical Support.

5-6 SEHI User’s Guide

SEHI Book Page 7 Friday, April 19, 1996 10:46 AM

Connecting the SEHI to the Network

F1/F2

ST Connectors

F1/F2

SMA 906 Connectors w/

Half Alignment Sleeves

SMA 905 Connectors

F3

ST Connectors

1490_15

Figure 5-3 The EPIM-F1, EPIM-F2, and EPIM-F3

SEHI User’s Guide 5-7

SEHI Book Page 8 Friday, April 19, 1996 10:46 AM

Chapter 5: Connecting to the Network

5.1.4

Connecting a Thin Coaxial Segment to an EPIM-C

To connect a thin coaxial segment to an EPIM-C:

1. Set the Internal Termination Switch, located to the right of the port and labeled TERM to one of the following:

• The On position (

) if the thin coaxial segment connected directly to the port is internally terminated at the port

• The Off position ( o ) if the thin coaxial segment is not internally terminated at the port or externally terminated

2. If the Internal Termination switch is in the On position, connect the

thin coaxial segment directly to the BNC port as shown in Figure 5-4.

3. If the Internal Termination switch is in the Off position, proceed with the following steps: a.

Attach a BNC T-connector to the BNC port on the module. b. Attach the thin coaxial segment to one of the female connectors on the T-connector.

NOTE

Terminate each segment attached to the T-connector. If a segment is not attached to one of the female connections on the T-connector, place a terminator on that connection.

c.

Attach another thin coax segment or a terminator to the other female connector on the T-connector.

For safety, ground only one end of a thin coaxial segment. Do

NOT connect EPIM BNC ports to earth ground. Connecting a thin coaxial segment to earth ground at more than one point could produce dangerous ground currents.

5-8 SEHI User’s Guide

SEHI Book Page 9 Friday, April 19, 1996 10:46 AM

Connecting the SEHI to the Network

When internal termination switch is set to Off ( ) follow these procedures:

Connect BNC T-connector to port.

Attach a terminator or terminated thin coaxial segment to one female connector of T-connector.

Connect a terminated thin coaxial segment to other female connector of T-connector.

Attach thin coaxial segment directly to

BNC connector when internal termination switch is set to On ( ).

1490_16

Figure 5-4 The EPIM-C

5.1.5

Connecting an AUI Cable to an EPIM-A

!

C AUT IO N

Ensure that the Signal Quality Error (SQE or “heartbeat”) test function is disabled on the external transceiver connected to the SEHI. The SEHI will not operate and the network will be unusable if the transceiver has the SQE test function enabled.

Refer to the applicable transceiver manual.

Connect an EPIM-A to an external network segment as follows:

1. Attach an external transceiver to the network segment to be connected to the AUI port. Refer to the applicable transceiver manual.

2. Attach an AUI cable no longer than 50 meters in length to the transceiver connected to the network in step 1.

3. Connect the AUI cable to the EPIM-A. (See Figure 5-5.)

4. Lock the AUI connector into place using the connector slide latch.

SEHI User’s Guide 5-9

P W

R

E P I M - A

SEHI Book Page 10 Friday, April 19, 1996 10:46 AM

Chapter 5: Connecting to the Network

TX

RX TX

RX TX

RX TX

RX TX

10

RX TX

9

RX TX

8

RX TX

7

4

3

2

1

PWR

1651_01

EPIM-A

EPIM-1

165213

Figure 5-5 The EPIM-A

5. Check that the PWR LED on the EPIM-A is on. If the LED is not on, contact Cabletron Systems Technical Support.

6. If the PWR LED is on with the AUI cable disconnected, continue with the following checks: a.

Check the AUI connections for proper pinouts. The pinouts for the

transceiver connection are listed in Chapter 3.

b. Check the cable for continuity.

c.

Reconnect the AUI cable to the SEHI and the device.

If the LED is still not on after reconnecting the segment, contact

Cabletron Systems Technical Support.

5-10 SEHI User’s Guide

SEHI Book Page 11 Friday, April 19, 1996 10:46 AM

Connecting the SEHI to the Network

5.1.6

Connecting an AUI Cable to an EPIM-X

!

C AUT IO N

The Signal Quality Error (SQE) switch remains in the OFF position for most network connections. However, some Data

Terminal Equipment (DTE) requires SQE. Refer to a DTE manual for SQE requirement information.

Perform the following steps to connect an EPIM-X to a device not requiring SQE:

1. Check that the SQE LED on the EPIM-X is off. If the SQE LED is on, check the position of the SQE switch.

NOTE

If the SQE light remains on, even though the SQE switch is in the OFF position, contact Cabletron Systems Technical

Support.

2. Attach one end of an AUI cable of up to 50 meters in length to the port

located on the EPIM-X (Figure 5-6) and connect the other end to the

intended node.

ON Position

(Toward Back of EPIM)

ON

OFF

OFF Position

(Toward Front of EPIM)

Figure 5-6 The EPIM-X

1490_18

SEHI User’s Guide 5-11

SEHI Book Page 12 Friday, April 19, 1996 10:46 AM

Chapter 5: Connecting to the Network

5.2

FINISHING THE INSTALLATION

The SEHI is now ready for operation. Before placing the network into service, test the installation thoroughly, making sure that all stations can be addressed and that the SEHI and all stations are indicating normal operation. Ensure that the networking software is configured properly to match the installed network. If there are any errors or abnormal operation,

proceed to Chapter 6, Troubleshooting.

5-12 SEHI User’s Guide

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

CHAPTER 6

TROUBLESHOOTING

This chapter contains instructions for using LANVIEW LEDs to troubleshoot physical layer network problems. It also describes how to reset the SEHI and how to reset the NVRAM switch.

6.1

INSTALLATION CHECKOUT

After connecting the SEHI to the network, verify that the packets pass between all Ethernet devices connected to the SEHI and any other devices connected to the network. If there is a problem with any of the attached devices, check the link as follows:

1. Check that the LNK LED, if applicable, for the port is on. If the LED is off, proceed with the following steps: a.

Check that the 10BASE-FL device at the other end of the fiber optic segment is powered up and that the TX and RX fibers are properly connected.

b. For twisted pair EPIMs such as the EPIM-T, verify that the connector on the twisted pair segment has the proper pinouts.

Refer to Chapter 3 for the pin assignments for twisted pair

connectors.

For the SEHI 10BASE-FL ports and the EPIM-F1, EPIM-F2, or

EPIM-F3 check that the TX and RX fibers are properly connected.

c.

Check the cable for continuity. Several tools are available for this test, depending on the media used.

d. Check that the twisted pair segments meet cable specifications for

dB loss as described in Chapter 3.

SEHI User’s Guide 6-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Chapter 6: Troubleshooting

2. If the remote station is ready and the LNK LED is on, but no data passes through the port, one of the following two conditions may exist:

• Network management disabled the port.

• The port is segmented either because the collision detector was on for more than 110

µ s or the SEHI detected more than 32 consecutive collisions on the attached segment. The affected port remains segmented until a good packet is transmitted/received without collisions.

If the LNK LED is still off, contact Cabletron Systems Technical

Support.

6.2

USING LANVIEW

The SEHI incorporates the Cabletron Systems LANVIEW status monitoring and diagnostics system. LANVIEW LEDs help diagnose problems such as power failure or cable fault. The SEHI uses the following LANVIEW LEDs:

PWR, for power status

CPU, for board status

RCV (Receive), LNK (Link), and CLN (Collision) for Ethernet status.

Figure 6-1 provides a quick reference chart of LED locations and

definitions. This chapter also includes a detailed description of each LED.

6-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Using LANVIEW

HubSTACK

10BASE-T HUB

WITH

LANVIEW®

SECURE

SEHI-22FL

RESET

COM

PWR

CPU

CLN

RCV

LNK

12 11 10 9 8 7 6 5 4 3 2 1

E

1

LED NAME

PWR

(Power)

CPU

(Central Processing Unit)

LED COLOR

Off

Green (Solid)

Off

Green (Flashing)

Green (Blinking)

Red (Solid)

Red CLN

(Collision)

RCV

(Receive)

LNK

(Link)

Yellow (Flashing)

Off

Green

Off

Figure 6-1 LANVIEW LEDs

DEFINITION

No power

Power

CPU in BOOT process

CPU initializing

CPU functioning

CPU not functioning

Collision

SEHI is receiving data

No activity

Link established

No link

165214

NOTE

Flashing indicates an irregular LED pulse.

Blinking indicates a steady LED pulse.

PWR

When this green LED is on, it indicates that the SEHI is receiving power.

If this LED is off, it indicates a loss of input power. Check the input power source (circuit breaker, fuse, etc.). If the proper source power is present, the problem could be with the SEHI.

CPU

This LED alternates from red to green during power up. After the boot is complete, the LED blinks green. A blinking green LED indicates normal operation. A red LED indicates a faulty processor.

SEHI User’s Guide 6-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Chapter 6: Troubleshooting

CLN

This red LED indicates that a collision has occurred on one of the ports.

RCV

When a yellow RCV LED flashes, it indicates that the SEHI is receiving data packets from the associated port segment. Each SEHI port has a corresponding RCV LED. The network RCV port LEDs are labeled 1-12 and the EPIM-1 RCV port LED is labeled E-1.

LNK

When a green LNK LED is on, it indicates an established link between the associated port and the device at the other end of the segment. The

LNK LED remains on as long as a link is maintained. Each SEHI

Network Port (ports 1–12) has a corresponding LNK LED.

6.3

USING THE RESET BUTTON

The SEHI incorporates a recessed RESET button. See Figure 6-1. The

RESET button initializes the SEHI processor. This button does NOT initialize Non-Volatile Random Access Memory (NVRAM), the nonvolatile random access memory where the SEHI stores network management parameters.

To use the RESET button, use a pen or pencil to press the button. When this is done, the SEHI initializes itself.

6-4 SEHI User’s Guide

SEHI Book Page 5 Friday, April 19, 1996 10:46 AM

Setting the NVRAM Switch

6.4

SETTING THE NVRAM SWITCH

To prevent the possibility of electrical shock, do not remove the chassis cover to access the NVRAM switch, and use only a non-metallic tool when moving the NVRAM switch.

The SEHI uses NVRAM (Non-Volatile Random Access Memory) to store user-entered parameters such as IP address and Community Names. To

reset these parameters to the factory defaults, refer to Figure 6-2 and

perform the following steps:

1. With the power ON and using a non-metallic tool, move the NVRAM switch to the UP position.

2. Press the RESET switch located on the front panel.

3. Wait until the unit boots (approximately 12 seconds).

4. Return the NVRAM switch to the DOWN position.

!

C AUT IO N

Failure to return the NVRAM switch to the DOWN position results in loss of user-entered parameters upon power shutdown and restart. The SEHI clears NVRAM if the unit is restarted with the switch in the UP position.

SEHI User’s Guide

Rear of Chassis

NVRAM Switch located behind grating

Figure 6-2 NVRAM Switch Location

165215

6-5

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

CHAPTER 7

LOCAL MANAGEMENT

This chapter explains how to set up a management terminal to access the

SEHI Local Management. It also explains how to use the Local

Management screens and commands.

Use Local Management to accomplish the following tasks:

• Assign an IP address and subnet mask.

• Select a default gateway.

• Control access to the SEHI through the community names established in the Community Name Table.

• Designate which Network Management Workstations receive trap messages from the device.

• Navigate through the Management Information Base (MIB) and manage the objects within it from a remote location. Given the appropriate security level, the MIB is accessible from the SEHI through SNMP Tools.

Local Management also allows the user to manage each non-intelligent stackable hub attached to the SEHI, and provides a Statistics screen to view error, collision, and traffic statistics for the entire stack, individual module, or individual port.

SEHI User’s Guide 7-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

7.1

LOCAL MANAGEMENT KEYBOARD

CONVENTIONS

All key names appear in this manual as capital letters. For example, the enter (return) key appears as ENTER and the space bar appears as SPACE

bar. Table 7-1 explains the keyboard conventions used in this manual as

well as the key functions.

Arrow Keys

Table 7-1 Keyboard Conventions

Key

RETURN Key and ENTER Key

SPACE bar and BACKSPACE Key

Function

These are selection keys that perform the same Local Management function. For example, “Press

ENTER” means press either ENTER or RETURN, unless this manual specifically instructs you otherwise.

These keys cycle through selections in some Local Management fields.

Use the SPACE bar to cycle forward through selections and use

BACKSPACE to cycle backward through selections.

These are navigation keys. Use the

UP-ARROW, DOWN-ARROW,

LEFT-ARROW, and RIGHT-ARROW keys to move the screen cursor. For example, “Use the arrow keys” means to press whichever arrow key moves the cursor to the desired field on the Local Management screen.

7-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Management Terminal Setup

7.2

MANAGEMENT TERMINAL SETUP

Use one of the following systems to access Local Management:

• A Digital Equipment Corporation VT series terminal

• A VT type terminal running emulation programs for the Digital

Equipment Corporation VT series

• An IBM or compatible PC running a VT series emulation software package

Use a console cable to attach the management terminal to the SEHI. The console cable is not included with the SEHI, but can be purchased separately from Cabletron Systems as part number SEHI-ACCY-KIT.

The SEHI-ACCY-KIT package provides an RJ45 Cable Kit that includes the following:

• UTP console cable with RJ45 connectors on each end

• Adapters for DB9 or DB25 connections

• Instruction Sheet

The following sections explain how to attach the console cable and set up the management terminal. Refer to the RJ45 Cable Kit Instruction Sheet for adapter pinouts and additional information.

SEHI User’s Guide 7-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

Console Cable Configuration

Use the RJ45 Cable Kit provided with the SEHI-ACCY-KIT package to attach the management terminal to the SEHI COM port as shown in

Figure 7-1.

Connect the console cable to the SEHI as follows:

1. Attach the male RJ45 connector to the COM port of the SEHI.

2. Attach the female end (25-pin or 9-pin, as applicable) to the COM port on the terminal.

Console Cable

HubSTACK

10BASE-T HUB

WITH

LANVIEW®

SEHI-24

COM

COM RJ45 Port

EPIM-2

EPIM-1

Management Terminal

COM Port

09162_17

Figure 7-1 Management Terminal Connection

7-4 SEHI User’s Guide

SEHI Book Page 5 Friday, April 19, 1996 10:46 AM

Management Terminal Setup

Management Terminal Setup Parameters

Table 7-2 lists the setup parameters for the local management terminal. If

the terminal is a Digital Equipment Corporation VT320 terminal, press F3 to access the Setup Directory. If the Local Management terminal uses terminal emulation of the VT320, refer to the equipment user manual for setup procedures.

Menu

Display Setup:

General Setup:

Communications

Setup:

Keyboard Setup:

Table 7-2 Terminal Setup Parameters

Function

Columns

Controls

Auto Wrap

Test Cursor

Mode

Cursor Keys

Transmit

Receive

XOFF

Bits, Parity

Stop Bit

Local Echo

Port

Transmit

Auto Answerback

Auto Repeat

Keyclick

Margin Bell

Warning Bell

Auto Answerback

Selection

80 Columns

Interpret Controls

No Auto Wrap

Cursor

7 Bit Control

Normal Cursor Keys

Transmit = 9600

Receive = Transmit

Any Option

8 Bits, No Parity

1 Stop Bit

No Local Echo

DEC-423,

Data Leads Only

Any Option

No Auto Answerback

Any Option

Any Option

Margin Bell

Warning Bell

No Auto Answerback

SEHI User’s Guide 7-5

SEHI Book Page 6 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

7.3

ACCESSING LOCAL MANAGEMENT

After configuring the local management terminal and properly attaching the cables to the SEHI, access the Local Management interface.

1. Power up the terminal. The password screen (Figure 7-2) appears.

SEHI LOCAL MANAGEMENT

Cabletron SEHI Revision X.XX.XX

Cabletron Systems Incorporated

35 Industrial Way, P.O. Box 5005

Rochester, NH 03867-0505 U.S.A.

(603) 332-9400

(c) Copyright Cabletron Systems, Inc. 1993

SEHI F/W Version: X.XX.XX

Boot Prom Version: X.XX.XX

SEHI Board Version: X.X

EnterUser Password:

1490_21

Figure 7-2 Password Screen

2. Enter the Password. The factory default password for Super-User access is “public” or press ENTER.

NOTE

The password is one of the community names specified in the

Community Name Table. Access to certain Local Management capabilities depends on the degree of access accorded that

community name. Refer to Section 7.5 for more details about

community names.

3. Press ENTER.

• If the password entry is invalid, the cursor returns to the beginning of the password entry field.

• If the password is valid, the associated access privilege appears briefly, then the SEHI Local Management Feature Selection

screen shown in Figure 7-3 appears.

7-6 SEHI User’s Guide

SEHI Book Page 7 Friday, April 19, 1996 10:46 AM

The Feature Selection Screen

NOTE

If the terminal keyboard is not used for 15 minutes, the Local

Management session ends and the screen defaults to the

Password screen.

SEHI LOCAL MANAGEMENT

Cabletron Systems Incorporated

P.O. Box 5005 Rochester, NH 03867-0505 U.S.A.

(603) 332-9400

FEATURE SELECTION

F6 COMMUNITY NAME TABLE

F7 IP ADDRESS ASSIGNMENT

F8 COMPONENT TRAP TABLE

F9 SNMP TOOL SUPPORT

DEVICE STATISTICS

EXIT LIM SERVICE

Figure 7-3 Feature Selection Screen

1490_22

7.4

THE FEATURE SELECTION SCREEN

The Feature Selection screen is the main menu screen for SEHI Local

Management. There are five screen options in the Feature Selection screen: Community Name Table, IP Address Assignment, Component

Trap Table, SNMP Tool Support, and Device Statistics. Use the arrow keys to highlight an option, then press ENTER (or press the corresponding Function Key). The selected screen appears.

To exit your Local Management session, use the arrow keys to highlight the EXIT LIM SERVICE command, then press ENTER.

SEHI User’s Guide 7-7

SEHI Book Page 8 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

7.5

THE COMMUNITY NAME TABLE SCREEN

To access the Community Name Table screen from the Feature Selection screen, use the arrow keys to highlight the Community Name Table option, then press ENTER or F6. The Community Name Table screen

shown in Figure 7-4 appears.

SEHI LOCAL MANAGEMENT

Cabletron SEHI Revision X.XX.XX

COMMUNITY NAME TABLE

COMMUNITY NAME ACCESS

PUBLIC

PUBLIC

PUBLIC

PUBLIC

BASIC-READ

READ-ONLY

READ-WRITE

SUPER-USER

SAVE IP TABLE TRAP TABLE SNMP TOOLS RETURN

F6 F7 F8 F9

1490_23

Figure 7-4 Community Name Table Screen

Community names are set through the Community Name Table option.

Community names are passwords to Local Management and are agents of security control to the SEHI. SEHI access is controlled by establishing up to four different levels of security authorization: Basic-Read, Read-Only,

Read-Write, and Super-User.

With Super-User access, the user changes the existing passwords by changing the community names. Only the community name assigned

Super-User access has full management privileges.

The following sections explain each field on the Community Name Table screen and provides instructions on how to change them.

COMMUNITY NAME

Displays the user-defined name through which a user can access Local

Management for the SEHI. Any community name assigned here acts as a password to Local Management.

7-8 SEHI User’s Guide

SEHI Book Page 9 Friday, April 19, 1996 10:46 AM

The Community Name Table Screen

ACCESS

Indicates the access status accorded each community name. Possible conditions are as follows:

BASIC-READ This allows Read-Only access to Local

Management, but excludes read privileges to the Component Trap screen.

READ-ONLY

READ-WRITE

This allows Read-Only access to Local

Management, but excludes access to security protected fields of the upper levels of authorization (Read-Write or Super-User).

This allows the user to read and write to Local

Management fields, excluding IP Address,

Subnet Mask, and Community Names.

SUPER-USER This access privilege gives the user read and write access to Local Management. Super-User allows read and write access to all modifiable parameters including: Community Names, IP

Addresses, Traps, and SNMP Objects.

Editing the Community Name Field

The password used to access Local Management at the Password screen must have Super-User privileges for the edits to take effect. If a password is entered with Basic-Read, Read-Only, or Read-Write privileges, Local

Management displays the message “AUTHORIZATION PROHIBITS

ACCESS”, and does not include editing capabilities.

To edit the Community Name field:

1. Use the arrow keys to highlight the Community Name field adjacent to the desired access level.

2. Enter the community name (maximum of 32 characters) into the field.

3. Press ENTER.

4. Repeat steps 1–3 for editing any of the other community names.

5. Use the arrow keys to highlight the SAVE command at the bottom of the screen, then press ENTER or F6. The “SAVED OK” message appears indicating that the edits have been saved to memory.

SEHI User’s Guide 7-9

SEHI Book Page 10 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

NOTE

The first time a user attempts to exit the screen without saving the changes, a “NOT SAVED?” message is displayed. The edits are lost if the user exits without saving the changes.

6. To exit the screen, press the appropriate Function key or use the arrow keys to highlight the RETURN command.

7. Press ENTER. The Feature Selection screen appears.

7.6

THE CONFIGURATION SCREEN

To access the Configuration screen from the Feature Selection screen, use the arrow keys to highlight the IP Address Assignment option, then

press ENTER or F7. The screen shown in Figure 7-5 appears.

SEHI LOCAL MANAGEMENT

Cabletron SEHI Revision X.XX.XX

CONFIGURATION

I/F IP Address SubNET Mask MAC Address

1 000.000.000.000 000.000.000.000 00-00-1d-05-dc-

36

Default Gateway: 0.0.0.0

Serial Port 1 Application: CONSOLE Baud Rate: 9600 --ACTIVE-

-

Port Enable Override: OVERRIDE DISABLED

SAVE COMMUNITY NAMES TRAP TABLE SNMP TOOLS RETURN

F6 F7 F8 F9

Figure 7-5 Configuration Screen

1490_24

Assign the IP Address, Subnet Mask, and Default Gateway through this screen. Use the Port Enable Override option to enable all device ports in the stack and override the Port Disable setting in the Statistics screen.

7-10 SEHI User’s Guide

SEHI Book Page 11 Friday, April 19, 1996 10:46 AM

The Configuration Screen

The following sections explain each field on the Configuration screen.

I/F

The number of the interface corresponding to the channels over which packets with that IP Address pass. On the SEHI, this value is “1.”

IP Address

Displays the IP address of the SEHI.

SubNET Mask

Displays the subnet mask for the SEHI. A subnet mask is a 32-bit quantity which “masks out” the network bits of the IP address. Do this by setting the bits in the mask to 1 when the network treats the corresponding bits in the IP address as part of the network or subnetwork address, or to 0 if the corresponding bit identifies the host.

MAC Address

Displays the physical address associated with the interface.

Default Gateway

Displays the default gateway for the SEHI. This field is not defined until an appropriate value is entered. The default gateway identifies the default gateway device that forwards packets to other IP subnetworks.

Serial Port Application

Displays the port application setting as CONSOLE.

Baud Rate

Displays the Baud Rate setting of the device attached to the SEHI through the serial port. The setting for the serial port is 9600.

Port Enable Override

This command lets the user override the Disable Port settings in the

Device Statistics screen to enable all ports in the stack.

SEHI User’s Guide 7-11

SEHI Book Page 12 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

Setting the IP Address

Use the following steps to set the IP Address:

1. Use the arrow keys to highlight the IP Address field.

2. Enter the IP address into this field. The format for this entry is

XXX.XXX.XXX.XXX, with values for XXX being from 0 to 255.

The screen beeps if non-numerics or adjacent dots are entered. If the entry does not have three dots, it is rejected.

3. Press ENTER. The IP address appears and the natural subnet mask for the user is generated and also appears.

4. Use the arrow keys to highlight the SAVE option, then press ENTER or F6. The “SAVED OK” message appears indicating that the changes have been saved to memory.

NOTE

The first time an attempt is made to exit the screen without saving the changes, a “NOT SAVED?” message is displayed.

The edits are lost if the user proceeds to exit without saving the changes.

Setting the Subnet Mask

NOTE

Consult the Network Administrator prior to setting the Subnet

Mask.

The subnet mask defines how the SEHI treats SNMP Trap IP destination addresses in its Trap Table.

• Set the subnet mask when workstations in the Trap Table reside on a different subnet (i.e., across a gateway or router), and these workstations are to receive SNMP traps.

• Use the subnet mask factory default setting of 0.0.0.0 when all trap designated workstations are on the SEHI subnet.

Use the following steps to set the subnet mask:

1. Use the arrow keys to highlight the SubNET Mask field.

7-12 SEHI User’s Guide

SEHI Book Page 13 Friday, April 19, 1996 10:46 AM

The Configuration Screen

2. Enter the subnet mask into this field. The format for this entry is

XXX.XXX.XXX.XXX with values for XXX being from 0 to 255.

3. Press ENTER.

4. Use the arrow keys to highlight the SAVE option, then press ENTER or F6. The “SAVED OK” message appears indicating that the changes have been saved to memory.

NOTE

The first time an attempt is made to exit the screen without saving the changes, a “NOT SAVED?” message is displayed.

The edits are lost if the user proceeds to exit without saving the changes.

Setting the Default Gateway

The Default Gateway field allows the user to identify the router through which the SEHI will be forwarding IP packets.

Use the following steps to set the Default Gateway:

1. Use the arrow keys to highlight the Default Gateway field.

2. Enter the gateway default mask in this field. The format for this entry is XXX.XXX.XXX.XXX with values for XXX being from 0 to 255.

3. Press ENTER. If the entry is accepted as a valid default gateway,

“OK” appears to the right of the field.

4. Use the arrow keys to highlight the SAVE option, then press ENTER or F6. The “SAVED OK” message appears indicating that the changes have been saved to memory.

Using the Port Enable Override

Use the following steps to override the Disable Port settings and enable all ports in the stack:

1. Use the arrow keys to highlight the Port Enable Override field.

2. Press ENTER to toggle from the default setting of “OVERRIDE

DISABLED” to “OVERRIDE ENABLED.”

3. The adjacent field displays “Y/N.” Enter Y to continue enabling all ports, or N to discontinue the port enable override. The message

“PORT ENABLED” appears after Y is entered.

SEHI User’s Guide 7-13

SEHI Book Page 14 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

Exiting the Configuration Screen

Use the following steps to exit the Configuration screen and return to the

Feature Selection screen:

1. Press the appropriate Function key. To return to the Feature Selection screen, use the arrow keys to highlight the RETURN command.

2. Press ENTER. The Feature Selection screen appears.

7.7

THE TRAP TABLE SCREEN

Access the Trap Table screen from the Features Selection screen using the arrow keys to highlight the Component Trap Table option, then press

ENTER or F8. The screen shown in Figure 7-6 appears.

SEHI LOCAL MANAGEMENT

Cabletron SEHI Revision X.XX.XX

TRAP TABLE

SNMP Community Name

<CR>

<CR>

<CR>

<CR>

<CR>

<CR>

<CR>

<CR>

Traps

N

N

N

N

N

N

N

N

SAVE COMMUNITY NAMES IP TABLE SNMP TOOLS RETURN

F6 F7 F8 F9

IP Address

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

0.0.0.0

1490_25

Figure 7-6 Trap Table Screen

The Trap Table defines the management stations that will receive SNMP

Traps for alarm/event notification. The following sections explain each field on the Trap Table screen and instructions on how to change them.

SNMP Community Name

Displays the community name included in the trap message sent to the network management station with the associated IP address.

7-14 SEHI User’s Guide

SEHI Book Page 15 Friday, April 19, 1996 10:46 AM

The Trap Table Screen

Traps

Enables transmission of the traps to the network management station with the associated IP address.

IP Address

Indicates the IP address of the workstation receiving trap alarms from the

SEHI.

Configuring the Trap Table

Use the following steps to configure the Trap table:

1. Use the arrow keys to highlight the SNMP Community Name field, then enter the community name.

2. Press ENTER.

3. Use the arrow keys to highlight the Traps field and enter Y (or y) to send alarms from the SEHI to the workstation, or N (or n) to prevent alarms from being sent.

4. Press ENTER.

5. Use the arrow keys to highlight the appropriate IP Address field.

6. Enter the IP address of the workstation to send traps to in this field.

The format for this entry is XXX.XXX.XXX.XXX, with the value of

XXX ranging from 0 to 255, and three dots, or else it returns to the beginning of the field.

7. Use the arrow keys to highlight the SAVE option, then press ENTER or F6. The “SAVED OK” message appears indicating that the changes have been saved to memory.

Exiting the Trap Table Screen

Use the following steps to exit the Trap Table screen and return to the

Feature Selection screen:

1. Press the appropriate Function key. To exit to the Feature Selection screen, use the arrow keys to highlight the RETURN command.

2. Press ENTER. The Feature Selection screen appears.

SEHI User’s Guide 7-15

SEHI Book Page 16 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

7.8

THE SNMP TOOLS SCREEN

This section describes how to use the SNMP Tools screen to access

Management Information Bases (MIBs). Access to screen options depends on the access status accorded to the user’s community name.

This section describes Super-User management capabilities.

SNMP Tools allows access to valuable MIB information. The user gets information about specific object identifiers (OIDs), edits the values of configurable OIDs, and requests the OID numerically sequential to the originally requested OID.

Other ways to view OIDs from the SNMP Tools screen include Walking,

Stepping, and Cycling. Walk and Cycle let the user review several OIDs at a time.

To access the SNMP Tools screen from the Features Selection screen, use the arrow keys to highlight the SNMP Tools Support option, then press

ENTER or F9. The SNMP Tools screen shown in Figure 7-7 appears.

SEHI LOCAL MANAGEMENT

Cabletron SEHI Revision X.XX.XX

SNMP TOOLS

SNMP COMMUNITY NAME: public

OID PREPEND: 1.3.6.1

GET SET GETNEXT WALK RECALL-OID STEP CYCLES REPEAT

F6 F7 F8 F9

RETURN

F10

1490_26

Figure 7-7 SNMP Tools Screen

The following sections describe SNMP Tools screen fields.

SNMP COMMUNITY NAME

Identifies the community name used as a password to determine access level to the MIB component.

7-16 SEHI User’s Guide

SEHI Book Page 17 Friday, April 19, 1996 10:46 AM

The SNMP Tools Screen

OID PREPEND

Specifies the number prefix common to all Object Identifiers (OIDs) found in the MIBs – 1.3.6.1 is the default prefix OID. This is a modifiable field.

GET

Allows the user to retrieve MIB objects using SNMP protocol.

SET

Allows users with Read-Write and Super-User access to change modifiable MIB objects, using SNMP protocol.

GETNEXT

Displays the OID following the current OID.

WALK

Allows the user to scroll through a section of the MIB leaf by leaf, from a user-specified object identifier. Leaves are the sections of the OID separated by periods. When a walk is initialized, the following categories for each walk entry, or step are displayed.

• Specified OID - gives the number tag for that OID.

• Size - identifies the number of bytes required to store that object.

• Type - specifies the variable type of the object (e.g., int = integer).

• Data - displays what the object identifier represents.

RECALL-OID

Recalls, from memory, the last OID used.

STEP

Displays the MIB walk, step by step, giving the user time to view specific leaves in detail.

CYCLES

Allows the user to specify the number of GETNEXT requests to cycle through and how much time will elapse between each request.

REPEAT

Repeats the last Get command, allowing the user to monitor changes to a specific OID.

SEHI User’s Guide 7-17

SEHI Book Page 18 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

Getting Individual OIDs

Use the following steps to “Get” individual OIDs:

1. Highlight GET, using the arrow keys, then press ENTER or F6.

“<GET> OID (=|F9)” appears.

2. Use one of the following options to enter the OID:

• Using the keyboard to enter the OID minus the prepend (e.g., if the prepend is 1.3.6.1, and 4.1.3 is entered, then the

OID=1.3.6.1.4.1.3).

• Entering an “ = ” and the OID suffix (e.g., if =4.1.3 is entered, then the OID=4.1.3). This allows the user to digress and not use the prepend.

• Pressing F9 to recall an OID already entered. The user can then use the keyboard to modify the recalled OID as necessary.

3. Press ENTER. If there is no instance of that OID, the return code will specify “MIB_NO_INSTANCE”, otherwise, information about that

OID data type, length, and value appear.

Getting the Next OID

Use the following steps to “Get” the next OID:

1. Highlight GETNEXT with the arrow keys, then press ENTER or F8.

“<GETNEXT> OID (=|F9)” appears.

2. Enter the desired OID, or OID extension. (Press F9 to recall the last

OID request. The recalled OID may then be modified as necessary.)

3. Press ENTER. If there is no instance of that OID, the return code will specify “MIB_NO_INSTANCE”, otherwise, information about that

OID data type, length, and value appear.

Setting an OID

Use the following steps to “Set” the next OID:

1. Highlight SET by using the arrow keys, then press ENTER or F7.

“<SET> OID (=|F9)” appears.

2. Enter the OID, minus the OID prepend. If the OID was previously entered, pressing F9 recalls that entry. The arrow keys may be used to modify the recalled OID if necessary.

7-18 SEHI User’s Guide

SEHI Book Page 19 Friday, April 19, 1996 10:46 AM

The SNMP Tools Screen

3. Press ENTER. If there is no instance of that OID, the return code will specify “MIB_NO_INSTANCE”, otherwise “DATA TYPE:” appears.

4. Enter the data type for that OID. Possible choices are integer, string, null, OID, IP address, counter, gauge, timeticks, and opaque.

5. Press ENTER. “DATA” appears.

6. Enter the value to correspond to the OID. If accepted, “<SET>

OPERATION CODE: XXXX <OK>” appears, otherwise an error message appears.

Viewing Multiple OIDs

View several OIDs at one time to scan a MIB for specific information.

“WALK” scrolls through OIDs numerically sequential to the initial OID request. “STEP” scrolls the MIB Walk, one OID at a time. Cycling allows the user to specify how many GETNEXT commands to cycle through.

Walking Through OIDs

Use the following steps to “Walk” through OIDs:

1. Highlight WALK, using the arrow keys, then press ENTER.

“<INITIAL> OID (=|F9)” appears.

2. Enter the OID (minus the prepend) and press ENTER. The screen begins walking through the sublayers of the MIB available from the specified OID. Each OID listed displays the specified OID, its size, its type, and the data it contains.

3. Press the SPACE bar to stop the walk, or wait for “***MIB WALK

COMPLETED***” to appear on the screen.

Stepping Through OIDs

Use the following steps to “Step” through OIDs (the user can step through only after a GETNEXT):

1. Highlight STEP, using the arrow keys, then press ENTER. “Specify

OID” appears.

2. Enter the OID (only the suffix is necessary) and press ENTER. The

Tools screen begins to scroll one OID at a time, through all of the sublayers of the MIB available for that OID.

SEHI User’s Guide 7-19

SEHI Book Page 20 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

Cycling Through OIDs

Use the following steps to “Cycle” through OIDs:

1. Use the arrow keys to Highlight CYCLES, then press ENTER.

2. Enter the number of cycles desired to occur after “ENTER CYCLE

COUNT:”, then press ENTER.

3. Enter how many seconds delay desired between get next requests after

“ENTER CYCLE DELAY (secs):”, then press ENTER.

Exiting the SNMP Tools Screen

Use the following steps to exit the SNMP Tools screen:

1. Use the arrow keys to highlight the RETURN command.

2. Press ENTER. The Feature Selection screen appears.

7.9

THE DEVICE STATISTICS SCREEN

This section describes the features of the Device Statistics screen. The user can view error, collision, and traffic statistics for the stack, a selected module, or a selected port. The user can also enable and disable ports.

To access the Statistics screen from the Features Selection screen, use the arrow keys to highlight the Device Statistics option, then press ENTER.

The Device Statistics screen shown in Figure 7-8 appears.

7-20

SEHI LOCAL MANAGEMENT

Cabletron SEHI Revision X.XX.XX

DEVICE STATISTICS

BYTES RECEIVED:

FRAMES RECEIVED:

STACK TOTAL

3792125

16547

MODULE: 1

67960

255

PORT: 1

67960

255

ERRORS RECEIVED:

COLLISIONS:

OOW COLLISIONS:

CRC ERRORS:

ALIGNMENT ERRORS:

RUNT PACKETS:

GIANT PACKETS:

PORT ADMIN. STATUS:

PORT SEG. STATUS:

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

ENABLE

UNSEGMENTED

ENABLE PORT DISABLE PORT

UPDATE -FREQ 3 Sec MODULE 1 PORT 1 RETURN

Figure 7-8 Device Statistics Screen

1490_27

SEHI User’s Guide

SEHI Book Page 21 Friday, April 19, 1996 10:46 AM

The Device Statistics Screen

The following sections describe Device Statistics screen fields:

BYTES RECEIVED

Displays the number of bytes received.

FRAMES RECEIVED

Displays the number of frames received.

ERRORS RECEIVED

Displays the number of errors received.

COLLISIONS

Displays the number of collisions received.

OOW COLLISIONS

Displays the number of Out Of Window collisions. OOW collisions are usually caused by the network being too long where the round trip propagation delay is greater than 51.2

µ s (the collision domain is too large), a station somewhere on the network is violating Carrier Sense and transmitting at will, or a cable somewhere on the network failed during the transmission of the packet.

CRC ERRORS

Displays the number of packets with bad Cyclic Redundancy Checks

(CRC) that have been received from the network. The CRC is a 4-byte field in the data packet that ensures that the transmitted data that is received is the same as the data that was originally sent.

ALIGNMENT ERRORS

Displays the number of errors due to misaligned packets.

RUNT PACKETS

Displays the number of runt packets received from the network. A runt packet is less than the minimum Ethernet frame size of 64 bytes, not including preamble.

GIANT PACKETS

Displays the number of packets received whose size exceeded 1518 data bytes, not including preamble.

SEHI User’s Guide 7-21

SEHI Book Page 22 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

PORT ADMIN. STATUS

Displays the administrative status of the port selected. The two possible status messages are Enable or Disable.

PORT SEG. STATUS

Displays the segmentation status of the port selected. The two possible status messages are Segmented or Unsegmented. The SEHI and SEH automatically partition problem segments, and reconnect non-problem segments to the network.

ENABLE PORT

This command lets the user enable the selected port.

DISABLE PORT

This command lets the user disable the selected port.

UPDATE-FREQ

This command lets the user select the time interval between

Stack/Module/Port counter updates. Choose update intervals up to 99 seconds in increments of 3 seconds.

MODULE

This command lets the user view statistics for a selected module in the stack. The SEHI is Module 1 and each SEH in the stack follows in

sequential order. Figure 7-9 shows each module number in the stack.

SEH - MODULE 5

SEH - MODULE 4

SEH - MODULE 3

SEH - MODULE 2

SEHI - MODULE 1

1490_28

Figure 7-9 Module Number Sequence

7-22 SEHI User’s Guide

SEHI Book Page 23 Friday, April 19, 1996 10:46 AM

The Device Statistics Screen

PORT

This command lets the user view port statistics for ports 1-26 of the selected module.

Selecting the Appropriate Module/Port

When the Device Statistics screen first appears, statistics are displayed for

Module 1 and Port 1. To view statistics for another module and port, use the Module x or Port x commands at the bottom of the screen.

To select a module or port:

1. Use the arrow keys to highlight the Module or Port command.

2. Press the SHIFT and + keys, or the SHIFT and keys until the desired module or port number appears.

3. Press ENTER. Statistics associated with the selected Module and Port appear.

Using the ENABLE PORT Command

The ENABLE PORT command lets the user enable the selected port. The user must first use the PORT command to select the desired port.

Use the following steps to set the ENABLE PORT command:

1. Use the arrow keys to highlight the ENABLE PORT command at the bottom of the screen.

2. Press ENTER. The corresponding port is enabled and the Port Admin

Status field is updated.

SEHI User’s Guide 7-23

SEHI Book Page 24 Friday, April 19, 1996 10:46 AM

Chapter 7: Local Management

Using the DISABLE PORT Command

The DISABLE PORT command lets the user disable the port selected in the PORT command. The user must first use the Port command to select the desired port.

To set the DISABLE PORT command:

1. Use the arrow keys to highlight the DISABLE PORT command at the bottom of the screen.

2. Press ENTER. The corresponding port is enabled and the Port Admin

Status field is updated.

Exiting the Device Statistics Screen

Use the following steps to exit the Device Statistics screen and return to the Feature Selection screen:

1. Use the arrow keys to highlight the RETURN command at the bottom of the screen.

2. Press ENTER. The Feature Selection screen appears.

7-24 SEHI User’s Guide

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

APPENDIX A

EPIM INFORMATION

A.1

EPIM SPECIFICATIONS

EPIMs enable the connection of the SEHI to the main network using different media types. Cabletron Systems offers a variety of EPIMs. The following sections explain specifications for each EPIM.

A.1.1

EPIM-T

The EPIM-T is an RJ45 connector supporting UTP cabling. It has an internal Cabletron Systems TPT-T 10BASE-T Twisted Pair Transceiver.

The slide switch on the EPIM-T determines the crossover status of the cable pairs. If the switch is on the X side, the pairs are internally crossed over. If the switch is on the = side, the pairs are not internally crossed

over. Figure A-1 shows the pinouts for the EPIM-T in both positions.

Position X

(crossed over)

1. RX+

2. RX-

3. TX+

4. NC

5. NC

6. TX-

7. NC

8. NC

Position =

(not crossed over)

1. TX+

2. TX-

3. RX+

4. NC

5. NC

6. RX

7. NC

8. NC

Figure A-1 EPIM-T Pinouts

1490_29

SEHI User’s Guide A-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Appendix A: EPIM Information

A.1.2

EPIM-F1 and EPIM-F2

The EPIM-F1 and EPIM-F2 shown in Figure A-2 support Multimode

Fiber Optic cabling. Each EPIM has an internal Cabletron Systems

FOT-F Fiber Optic Transceiver. The EPIM-F1 is equipped with SMA

Connectors and the EPIM-F2 is equipped with ST Connectors.

Specifications for the EPIMs are listed below.

1490_30

Figure A-2 EPIM-F1 and EPIM-F2

Parameter

Receive

Sensitivity

Peak Input Power

Transmitter Power

50/125

µ m fiber

62.5/125

µ m fiber

100/140

µ m fiber

Error Rate

Typical

Value

Worst

Case

-30.5 dBm -28.0 dBm

-7.6 dBm -8.2 dBm

Worst

Case

Budget

-13.0 dBm -15.0 dBm 13.0 dB

-10.0 dBm -12.0 dBm 16.0 dB

-7.0 dBm -9.0 dBm

Better than 10 -10

19.0 dB

Typical

Budget

17.5 dB

20.5 dB

23.5 dB

1490_31

The transmitter power levels and receive sensitivity levels listed are Peak

Power Levels after optical overshoot. Use a Peak Power Meter to compare the values given above to those measured on any particular port. If Power

Levels are being measured with an Average Power Meter, add 3 dBm to the measurement to compare the measured values to the values listed (i.e.

-33.5 dBm average + 3 dBm =-30.5 dBm peak).

A-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

EPIM Specifications

A.1.3

EPIM-F3

The EPIM-F3 (Figure A-3) supports Single Mode Fiber Optic cabling. It

has an internal Cabletron Systems FOT-F Fiber Optic Transceiver and is equipped with ST Connectors. EPIM-F3 specifications are listed below.

Figure A-3 EPIM-F3

1490_32

Transmitter Power decreases as temperatures rise and increases as temperatures fall. Use the Output Power Coefficient to calculate increased or decreased power output for the operating environment. For example, the typical power output at 25

°

C is -16.4 dBm. For a 4

°

C temperature increase, multiply the typical coefficient (-0.15 dBm) by four and add the result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).

Parameter

Transmitter Peak

Wave Length

Spectral Width

Rise Time

Fall Time

Duty Cycle

Bit Error Rate

Typical Minimum

1300 nm

60 nm

3.0 ns

2.5 ns

1270 nm

-

2.7 ns

2.2 ns

50.1%

Better than 10 -10

49.6%

Maximum

1330 nm

100 nm

5.0 ns

5.0 ns

50.7%

The transmitter power levels given above are Peak Power Levels after optical overshoot. Use a Peak Power Meter to compare the values given above to those measured on any particular port. If you are using an

Average Power Meter, add 3 dBm to the measurement to compare the average power values to the values listed above

(i.e., -33.5 dBm average + 3 dBm = -30.5 dBm peak).

SEHI User’s Guide A-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Appendix A: EPIM Information

A.1.4

EPIM-C

The EPIM-C supports thin coaxial cabling and is equipped with an internal Cabletron Systems TMS-3 Transceiver. Use the TERM switch on the front of the EPIM-C to set the internal 50-ohm terminator. This eliminates the need to connect the port to a T-connector and terminator.

Figure A-4 shows the setting for the terminator switch.

TERM

EPIM-C

Internal Termination Switch

= On (internally terminated)

= Off (need external termination)

1490_34

Figure A-4 EPIM-C z

Connector Type

BNC receptacle, with gold center contact, for use with BNC type

T-connectors and RG58 thin coaxial cable.

Grounding

The BNC port of the Coaxial Interface Module is not connected to earth ground.

For safety, ground only one end of a thin coaxial segment. Do

NOT connect EPIM BNC ports to earth ground. Connecting a thin coaxial segment to earth ground at more than one point can produce dangerous ground currents.

A-4 SEHI User’s Guide

SEHI Book Page 5 Friday, April 19, 1996 10:46 AM

EPIM Specifications

A.1.5

EPIM-A and EPIM-X (AUI Port)

The EPIM-A is a DB15 female connector used to attach segments to an external transceiver. The EPIM-X is equipped with dual internal transceivers. It has a DB15 male connector used to attach segments to an

AUI cable. Figure A-5 shows both modules.

Figure A-5 The EPIM-A and EPIM-X

Pin 1

2

3

6

7

4

5

Logic Ref.

Collision +

Transmit

Logic Ref.

Receive +

Power Return

No Connection

8 Logic Ref.

Connector Shell: Protective Ground

9 Collision -

10 Transmit -

11 Logic Ref.

12 Receive -

13 Power (+12Vdc)

14 Logic Ref.

15 No Connection

1490_35

SEHI User’s Guide A-5

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

APPENDIX B

IMAGE FILE DOWNLOAD USING OIDs

This appendix provides instructions for setting up a TFTP server and to download an image file to the SEHI by setting specific MIB OID strings.

Set the OID strings with the SNMP Tools screen described in Chapter 7,

Section 7.8.

NOTE

Download an image file to the SEHI with a remote management package such as SPECTRUM, SPECTRUM

Element Manager, or the appropriate SPECTRUM Portable

Management Application. Refer to the specific package documentation for image file download procedures.

The SEHI supports the Standard TFTP Download application. In this application the SEHI automatically goes offline during the image download. After the download, the SEHI programs FLASH, then reboots with the new image.

Before downloading the image to the SEHI, you must complete the following steps:

1. Decompress the image file on a DOS PC using the PKUNZIP utility included with the image.

NOTE

The PKUNZIP utility requires a DOS PC. You must decompress the image file on the DOS PC before you load the image file onto the TFTP server.

2. Load the decompressed image file onto the TFTP server.

NOTE

For information on how to set up a workstation as a TFTP server, refer to your specific workstation documentation. These instructions include limited information and guidelines for setting up a UNIX workstation to work as a TFTP server.

SEHI User’s Guide B-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Appendix B: Image File Download Using OIDs

B.1

SETTING UP A UNIX WORKSTATION AS A TFTP

SERVER

Due to variations between UNIX systems and individual configurations, this section provides only GUIDELINES for configuring a UNIX workstation to perform an image file download. The instructions include command examples, where appropriate. Bold lettering in examples indicates operator entry.

!

C AUT IO N

If unsure about how to properly configure a UNIX workstation using these guidelines, contact the Systems Administrator.

To set up a UNIX workstation, proceed as follows:

1. Edit the /etc/ethers file by adding the SEHI MAC address, followed by a unique name (e.g., 00:00:1d:32:0c:1b sehi).

2. Edit the /etc/hosts file by adding the SEHI MAC address and follow it with the same unique name used in step 1 (e.g., 00:00:1d:32:0c:1b sehi).

3. If the workstation already has a /tftpboot directory, confirm the TFTP setup of the workstation as follows:

Request a process status and grep for TFTP (e.g., unix% ps-aux | grep

tftp).

The following information represents a typical output: user 161 7.7

root 87 0.0

1.2

0.9

32 184

48 136 p3

?

S 12:00 grep tftp

S 11:05 tftp -s

The term tftp -s , located at the end of the root string, indicates TFTP is active. If TFTP is NOT running, only the grep process appears.

4. If the workstation does NOT have a /tftpboot directory, than create one

(e.g., unix% mkdir tftpboot).

5. Ensure that the /tftpboot directory is not owned (e.g., unix% chown

nobody tftpboot).

B-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

Standard TFTP Download

NOTE

The next step requires decompression of the zipped image file.

If you do not have a UNIX unzip utility, access to a PC with

PKUNZIP, or a way to FTP the decompressed image to your

UNIX workstation, contact Cabletron Systems Technical

Support.

6. Store the hex image file in the /tftpboot directory as sehi.hex.

7. Edit the /etc/inetd.conf file by removing anything prior to the tftpboot daemon (e.g., the # sign) that comments-out the line.

8. Kill the inetd process (e.g., unix% kill -HUP ‘process ID number’), and then restart the process (e.g., unix% inetd), to enable the revised inetd.conf file.

NOTE

The user must request a process status and grep for inetd to obtain the process ID number (refer to step 3).

B.2

STANDARD TFTP DOWNLOAD

Table B-1 provides a step-by-step procedure for downloading the

firmware image file. This section provides specific MIB OIDs, MIB names, and the required setting for proper image file download. Refer to the specific MIB walking tool documentation for instructions on how to set MIB OID strings.

The Download OIDs for CabletronSystems products reside in Cabletron

Systems enterprise MIBs (group 52). The specific OIDs necessary to perform an image file download reside in the common download group under ctDL (Cabletron Download). The full OID string to reach this group is

1.3.6.1.4.1.52.4.1.5.8.1.

When performing the steps in Table B-1, keep the following in mind:

• Follow the steps in order.

• Enter the IP address of the TFTP server in standard dotted decimal notation (e.g., 132.177.118.24).

SEHI User’s Guide B-3

SEHI Book Page 4 Friday, April 19, 1996 10:46 AM

Appendix B: Image File Download Using OIDs

• Enter the FULL path to the image file in the ctDLTFTPRequest OID, including the name of the image file (e.g., c:/tftpboot/sehi.hex).

Table B-1 Standard TFTP Download Procedure

1.

2.

Step

3.

4.

5.

OID Name OID Number

Data

Type

SNMP OID

Data ctDLForceOnBoot 1.3.6.1.4.1.52.4.1.5.8.1.1.0 integer 1 ctDLCommitRAMToFlash 1.3.6.1.4.1.52.4.1.5.8.1.2.0 integer 1 ctDLTFTPRequestHost 1.3.6.1.4.1.52.4.1.5.8.1.4.0

IP address

Enter the

IP address of the TFTP server.

ctDLTFTPRequest 1.3.6.1.4.1.52.4.1.5.8.1.5.0 string

(ASCII)

Enter the path to the image file.

ctDLInitiateColdBoot 1.3.6.1.4.1.52.4.1.5.8.1.3.0 integer 1

B-4 SEHI User’s Guide

SEHI Book Page 1 Friday, April 19, 1996 10:46 AM

INDEX

Numerics

10BASE-FL

attenuation 3-2 budget and propagation delay 3-2 cable requirements 3-2

10BASE-T

cable length 3-3

crosstalk 3-4

delay 3-3 impedance 3-3 insertion loss 3-3 jitter 3-3

noise 3-4 temperature 3-4

UTP and STP specifications 3-3

A

AUI cable 5-9, 5-11

C

Cable specifications 3-1

fiber optic 3-2

UTP and STP 3-3

Cables

HubSTACK Interconnect 2-4

COM Port 3-5

D

Default Gateway 7-13

Device Statistics screen 7-20

Dimensions 3-8

E

Environmental requirements 3-8

EPIM installation 4-9

EPIM specifications 2-4

EPIM-A and EPIM-X A-5

EPIM-C A-4

EPIM-F1/F2 A-2

EPIM-F3 A-3

EPIM-T A-1

F

FLASH EEPROMs 2-2

FLASH Firmware Image 4-1

H

Help

related manuals 1-3

HubSTACK

cable requirements 3-2

HubSTACK Interconnect cables 2-4

I

IP address 7-12

L

LANVIEW 6-2

LEDs 6-3

Local Management 7-1

accessing 7-6

community name table 7-8

configuration screen 7-10

console cable 7-4

device statistics 7-20

port ENABLE override 7-13 setting default gateway 7-13

setting IP address 7-12 setting subnet mask 7-12

SNMP tools 7-16

terminal requirements 7-3

terminal setup 7-5

trap table 7-14

SEHI User’s Guide Index-1

SEHI Book Page 2 Friday, April 19, 1996 10:46 AM

Index

N

Network connection 5-1

AUI 5-9, 5-11

EPIM-A 5-9

EPIM-C 5-8

EPIM-F1/F2/F3 5-5

EPIM-T 5-4

EPIM-X 5-11

fiber optic segment 5-5

thin coaxial 5-8

Unshielded Twisted Pair 5-4

Network port specifications

SEHI-22FL 3-4

NVRAM

pre-installation checkout 4-2

setting 6-5

O

OIDs 7-16

Operating specifications 3-6

P

Port ENABLE override 7-13

Power supply requirements 3-7

R

Rack mounting

accessory kit 2-4

Remote network management 2-3

Reset 6-4

S

Safety requirements 3-8

SEHI features 2-2

Size

dimensions 3-8

SNMP tools screen 7-16

Subnet mask 7-12

T

Transceiver requirements 3-5

Trap Table screen 7-14

Troubleshooting 6-1

Index-2 SEHI User’s Guide

SEHI Book Page 3 Friday, April 19, 1996 10:46 AM

POWER SUPPLY CORD

The mains cord used with this equipment must be a 2 conductor plus ground type with minimum 0.75 mm square conductors and must incorporate a standard IEC appliance coupler on one end and a mains plug on the other end which is suitable for the use and application of the product and that is approved for use in the country of application.

GERMAN:

Die Netzleitung, die mit diesem Geraet benuetzt wird, soll einen zwei Leiter mit

Erdleiter haben, wobei die Leiter mindestens 0.75 mm sind, mit einer normalen

IEC Geraetesteckdose an einem Ende und einem Geraetestecker am anderen Ende versehen sind, der fuer den Gebrauch und die Anwendung des Geraetes geeignet und der zum Benuetzen im Lande der Anwendung anerkannt ist.

SPANISH:

El cable principal de la red eléctrica utilizado con este equipo debe tener 2 conductores y 1 toma de tierra con un mínimo de 0.75 mm2 cada uno y necesita tener un aparato de acoplamiento standard IEC en un extremo y un enchufe para el cable principal de la red eléctrica en el otro extremo, lo cual sea adecuado para el uso y applicación del producto y lo cual sea aprobado para uso en el pais de applicación.

FRENCH:

Le cordon d' alimentation reliant cet appareil au secteur doit obligatoirement avoir deux fils conducteurs de 0.75 mm2 minimum et un fil de terre. It doit également

être équipé du côté appareil d'une fiche agrée IEC et du côte secteur, d'une prise adaptée à l'usage du produit et aux normes du pays où l'appareil est utilisé.