Ravel | RE-2508 | User manual | RE - Master TECHNICAL D ATA TERMINAL DETAIL

Add to my manuals
18 Pages

advertisement

Ravel | RE-2508 | User manual | RE - Master TECHNICAL D ATA TERMINAL DETAIL | Manualzz
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
FEATURES:
Fully confirms IS 2189: 1988
Rugged CRCA with powder coated finish.
Operates on 230V, A.C supply.
Battery backup with built in charging.
Error free fire / fault status in unambiguous coloured LED Indication.
20 X 4 LCD Dot Matrix display.
Low battery / warning audio/ visual display.
Battery fail warning audio
Charger on indication.
A.C fail audio / visual warning.
Relay output for actuators.
Up to 256 Zones( Panel Availability for 64/128/256).
RS485 for repeater/slave communication Shielded or twisted wire (CAT5E or CAT6).
Slave panel Compatible only with RE 2554/RE2558 .
Slave Isolation facility.
Events Memory with RTC.
RS 232 facility.
Ethernet Module (RJ45) Facility. (Optional)
Dimension of the panel : 350 x 300 x 100 mm(l x h x d)
TECHNICAL DATA
1.
2.
3.
4.
5.
2.
3.
RE - Master
Power Supply:
AC Input Supply
DC Input Supply
Operating Conditions
Operating Voltage
Charging Current
Colour of the Panel
:
:
:
:
:
:
230 V AC, 50Hz
24 V DC
o
-10 to 45 C, 95 % RH Max.
24 V DC
27.4 VDC.
Broken White (Red, Red Texure - Optional)
SOUNDER OUTPUT:
Standard Common Output
:
2Amps .
REMOTE INDICATION OUTPUTS:
Outputs
:
Fire Relay Contacts (2No’s of 230 V 2A contact).
Fault Relay Output (1 No. of 230 V 2A contact)
TERMINAL DETAIL
ANALOG ADDRESSABLE
FIRE ALARM PANEL
Avani
By
FEATURES
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
As per UL 864, 9th Edition & NFPA 72.
32 bit processor - Arm Cortex M3.
Operates on 120 to 220V AC, 60 / 50 Hz.
Battery Backup 24V DC with Built in charger.
40 x 4 Characters LCD display.
Touch key pad for user friendly operation.
Maximum 4 number of loop cards with Class A or B wiring.
Maximum 198 devices (99 Detectors + 99 Modules) per loop.
Upto 192 Grouping Facility.
Auto Learning facility.
Device / Detector wise Configuration facility.
Auto device type verification.
Programmable Detector sensitivity.
2000 Event storage with Real Time Clock.
Day / Night Mode Facility.
USB 2.0 Interface for PC connectivity.
RS 485 Communication facility for Network / Repeater.
Auto dialer / GSM Module (Optional).
Ethernet Module (Optional).
Printer Interface Module (Optional).
Programmable Auto Silence Facility.
Programmable Trouble Reminder Facility.
Programmable AC Loss Delay.
Programmable Silence Inhibit.
Loop wise test facility.
Battery low visual warning with audible tone.
Three Programmable Form C relay for Fire, Fault and
supervisory.
Supervised 24V DC output.
Two nos. of Supervised Notification Appliance Circuits.
SPECIFICATION
Primary Power
120 / 220VAC + 10% -15%, 60 / 50 Hz.
Standby Power
24V D.C (2 Nos of 12v, 14Ah ) Sealed Lead acid battery
Operating Condition
Operating Temperature 0 - 49° C/32-120° F.
Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/96 ±3° F.
Charging Circuit
Charging Voltage 28 V, ±0.2V Nominal
Charging Current 1.2A (Max.).
Signaling Line Circuits
Class A or B loop card: 4 Nos. Maximum.
No of Device per loop: 198 (99 Detectors + 99 Modules System Sensor).
Multi protocol devices per loop : 254.
Loop resistance: 40 ohms (Max.).
Loop capacitance: 0.6 µf (Max.).
Loop Current: 300mA (Max.).
Initiating Device Circuits
One conventional zone Class B Style B/C operation.
Normal Operating Voltage: 14 - 21 VDC.
Alarm Current: 15 - 30mA.
Short Circuit Current: 45mA Maximum.
Loop resistance: 100 ohms Maximum.
End-Of-Line Resistor: 4K7, 1/2watt
Standby Current: 7mA (2mA for Detectors)
Programmable Input Circuits
No. of Inputs: 1
Normal Operating Voltage: 4 - 8 VDC.
Short Circuit Current: 3mA Maximum.
Loop resistance: 100 ohms Maximum.
End-Of-Line Resistor: 4K7, 1/2watt
Standby Current: 1.25mA
Notification Appliance Circuits
Class B, Style - Y wiring
Operating Nominal Voltage: 24 VDC Nominal
Current for NACs: 2Amps (1A per circuit)
Line Drop: 2.4V
End-Of-Line Resistor: 4K7, ½ watt
D.C. Output
Supervised 24VDC, 300mA Max.
Three Programmable Form C Relays
Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC.
Power Factor: 0.6
Avani
By
ANALOG ADDRESSABLE
FIRE ALARM REPEATER PANEL
FEATURES
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
As per UL 864, 9th Edition & NFPA 72.
Operates on 120 to 220V AC, 60 / 50 Hz.
Battery Backup 24V DC with Built in charger.
32 bit processor - Arm Cortex M3.
40 X 4 Characters LCD display.
Touch key pad for user friendly operation.
Remote silence, reset and evacuate can be done from repeater panel.
Repeats all the indication / Information of main panel.
All programming of the main panel can be done from the Repeater
Panel.
RS 485 Communication for Standalone / Network Repeater.
10,000 Event storage with Real Time Clock.
Battery low visual warning with audible tone.
One Supervised Notification Appliance Circuits.
One Form C relay for Common Fire.
RE - 1504
CONVENTIONAL PANEL WITH
ADDRESSABLE FEATURES
FEATURES
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
RE - 1508
As per NFPA-72 standards.
Rugged CRCA sheet with powder coated finish.
Network able / Standalone panel.
4/8 Class B conventional initiating device circuit (IDC).
Ø All zones accept smoke detectors and any normally open contact device.
Ø Any Zone can be configured as Alarm or supervisory Zone.
Class B Notification Appliance Circuits (NAC).
Operates on 220v 50Hz, AC Mains power supply
Standby (battery) backup 24v DC power supply with built in charger.
All field wiring circuits are supervised.
AC Low voltage cutoff.
Programmable NAC.
Programmable IDCs.
Programmable AC loss delay.
Programmable Trouble reminder.
Programmable Form -C relay for fire / Fault / Supervisory.
2 Form-C relay for Fire.
Alarm Verification Facility. **
1000 history events with RTC.
Error free Fire / Fault status in unambiguous colored LED indication.
Main, Standby status audible and visual indication.
Battery Low visual warning with audible tone.
Zone Isolation Facility.
Peer to Peer networking facility (upto 16 panels ) .
Ground fault annunciation facility at 0 ohms.
All field wiring circuits are Power limited except 220v A.C. and Battery.
Advanced features for the System Sensor series 300 detectors.
ª 32 Detectors per Zone.
ª Active Scan Devices facility.
ª Individual detector address with location.
** - This facility is available only in system sensor 300 series protocol disable condition.
Primary Power
220VAC ± 10%, 50 Hz, 2.5Amps.
Standby Power
24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery).
Operating Condition
Operating Temperature 15 - 35° C/60-95° F.
Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F.
Technical Specification
Charging Circuit
Charging Voltage 28.4V, ±0.2V
Charging Current 800mA (Max.).
Initiating Device Circuits
All zones are Class B Style C operation.
Normal Operating Voltage: 14 - 20 VDC.
Alarm Current: 15 - 30mA.
Short Circuit Current: 40mA Maximum.
Loop resistance: 40 ohms Maximum.
End-Of-Line Resistor: 4K7, 1/2watt
Standby Current: 6mA (2mA for Detectors)
Notification Appliance Circuits
Class B Style - Y wiring
Operating Nominal Voltage: 24VDC Special Application
Current for NACs: 1Amps
Line Drop: 1.8V
End-Of-Line Resistor: 4K7, 1/2watt
Resettable D.C. Power
Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4
wire smoke detector)
Common Three Form C Relays
Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC.
Power Factor: 0.6
Ordering Information
RE 1504 W/R
4 IDC
RE 1508 W/R
8 IDC
W- White Colour; R - Red Colour.
Dimension of panel : 425 X 350 X 110mm ( Width x Height X Depth)
Ravel Electronics Pvt. Ltd.
150A, Electronic Industrial Estate, Perungudi, Chennai - 96. India.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599
Mail: [email protected] URL: www.ravelfirepanels.com
RE - 2554
RE - 2558
FEATURES



























Fully complies with UL -864 and NFPA-72.
Rugged CRCA sheet with powder coated finish.
Operates on 120 - 220v 50 /60 Hz, AC Mains power supply.
16x2 Dot Matrix LCD Display.
4/8 Class B initiating device circuit (IDC).
 All zones accept smoke detectors and any normally open contact device.
 Any Zone can be configured as Alarm or supervisory Zone.
2 Class B Notification Appliance Circuits (NAC).
Standby (battery) backup 24v DC power supply with built in charger
Error free Fire / Fault status in unambiguous colored LED indication.
System ON indication.
Main, Standby status audible and visual indication.
Battery Low visual warning with audible tone.
FormC relays for fire, fault and supervisory.
Resettable / uninterrupted 24v D.C. Output.
RS 485 Communication facility (Optional).
Lamp Test facility.
Walk Test facility.
Zone Isolation facility with loop voltage cut off.
Earth fault annunciation facility at 0 ohms.
All field wiring circuits are Power limited except 120 - 220v AC and Battery.
All field wiring circuits are supervised.
AC Low voltage cutoff.
Programmable NAC's.
Programmable IDC's.
Programmable Supervisory Mode.
Programmable AC loss delay.
Alarm verification facility.
Programmable Trouble reminder facility.
RE 2554-58
SPECIFICATION
Primary Power CN1 (RE-SMPS-4A-R1)
120 - 220VAC ± 10%, 50 Hz, 2.5Amps.
Standby Power CN10
24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery).
Operating Condition
Operating Temperature 0 - 49° C/32-120° F.
Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F.
Charging Circuit
Charging Voltage 28.2V, ±0.5V
Charging Current 800mA (Max.).
Initiating Device Circuits CN 8
All zones are Class B Style B/C operation (Programmable).
Normal Operating Voltage: 14 - 21 VDC.
Alarm Current: 15 30mA.
Short Circuit Current: 45mA Maximum.
Loop resistance: 100 ohms Maximum.
End-Of-Line Resistor: 3K9, 1/2watt
Standby Current: 7mA (2mA for Detectors)
Notification Appliance Circuits CN5 and CN6
Class B Style - Y wiring
Operating Nominal Voltage: 24VDC Special Application
Current for all NACs: 1.2Amps (0.6A per circuit)
Current Limit: CN5 and CN6 via Thermal Fuse
Line Drop: 1.8V
End-Of-Line Resistor: 3K9, 1/2watt
Note:
For compatible devices refer Chapter 9(CD 01).
D.C. Power CN7
Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4 wire smoke
detector)
Common Three Form C Relays CN2, CN3, CN4
Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC.
Power Factor: 0.6
Dimension of the Panel : 440 x 340 x 120 mm ( length x height x width )
RAVEL ELECTRONICS PVT LTD.,
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
FEATURES:
RE 102
F
F
F
F
Rugged CRCA sheet with powder coated finish.
F
F
F
F
F
F
F
F
F
F
Switch Mode Power Supply.
Operates on 220v, 50Hz AC supply.
Standby battery back up with built in charging.
Fire / Fault status in unambiguous colored LED
indication.
Tactile key pad for easy panel operation.
System on indication.
Main, Standby status indication.
Low Battery visual warning with audible tone.
Relay output for actuators for Fire and Fault.
Lamp Test facility.
Zone wise one man Walk Test facility.
Zone wise Isolation facility with loop voltage cut off.
Compatible to all types of conventional detectors.
TECHNICAL DATA
1.
Power Supply:
AC Input Supply
DC Input Supply
2. Operating Conditions
3. Operating Voltage
4. Normal Loop Voltage
5. Open Threshold Current
6. Short Circuit Threshold Current
7. Stand by Threshold Current
( EOL Current + detector's Current)
8. Alarm Current
9. Quiescent Current
10. Colour of the Panel
11. Panel Size
12. Approximate Weight
13.
14.
ALARM OUTPUT:
Common Hooter Output
REMOTE OUTPUTS:
Outputs
:
:
:
:
:
:
:
:
:
220 V AC, 50Hz
24 V DC
o
-10 to 45 C, 95 % RH Max.
24 V DC
20.7 DC
4.2 mA
40 mA
8.2 mA
:
:
:
:
:
20 - 35 mA
60mA
Broken White (Red, Red Texure - Optional)
350 X 250 X 100(Width X Height X Depth)
4Kgs.
:
24V@1A.
Fire, Fault Relay Contacts (30V AC/ DC @ 2A contact).
RAVEL ELECTRONICS PVT LTD.,
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
FEATURES:
RE 104
F
F
F
F
Rugged CRCA sheet with powder coated finish.
F
F
F
F
F
F
F
F
F
F
Switch Mode Power Supply.
Operates on 220v, 50Hz AC supply.
Standby battery back up with built in charging.
Fire / Fault status in unambiguous colored LED
indication.
Tactile key pad for easy panel operation.
System on indication.
Main, Standby status indication.
Low Battery visual warning with audible tone.
Relay output for actuators for Fire and Fault.
Lamp Test facility.
Zone wise one man Walk Test facility.
Zone wise Isolation facility with loop voltage cut off.
Compatible to all types of conventional detectors.
TECHNICAL DATA
1.
Power Supply:
AC Input Supply
DC Input Supply
2. Operating Conditions
3. Operating Voltage
4. Normal Loop Voltage
5. Open Threshold Current
6. Short Circuit Threshold Current
7. Stand by Threshold Current
( EOL Current + detector's Current)
8. Alarm Current
9. Quiescent Current
10. Colour of the Panel
11. Panel Size
12. Approximate Weight
13.
14.
ALARM OUTPUT:
Common Hooter Output
REMOTE OUTPUTS:
Outputs
:
:
:
:
:
:
:
:
:
220 V AC, 50Hz
24 V DC
o
-10 to 45 C, 95 % RH Max.
24 V DC
20.7 DC
4.2 mA
40 mA
8.2 mA
:
:
:
:
:
20 - 35 mA
60mA
Broken White (Red, Red Texure - Optional)
350 X 250 X 100(Width X Height X Depth)
4Kgs.
:
24V@1A.
Fire, Fault Relay Contacts (30V AC/ DC @ 2A contact).
RAVEL ELECTRONICS PVT. LTD.,
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
FEATURES:
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Rugged CRCA sheet with powder coated finish.
Operates on 220V, A.C supply
Battery backup with built in charging.
16 X 2 LCD Dot Matrix Display.
Evacuate and Key pad Enable, Disable Facility.
Low battery visual warning with audible tone.
2 Form C Relay output for fire.
One Programmable relay for fire/fault/solenoid on /timer
on.
Remote fire indication with Audible Tone.
Compatible to all types of conventional detectors.
Zone Disable (Isolation) facility with loop voltage cut off.
Resettable 24v DC output for 4 wire detectors .
Three 24V Hooter Output (Fire, after Cross zone, after gas
release) .
Two mode operation facility (Auto / Manual).
Programmable FAP input selection Facility.
Programmable Solenoid Output with On and OFF Timer.
Main / Standby Cylinder output Facility .
Gas Inhibition and Instant release facility.
Manual Gas Release with or without timer.
Actuator pressure low sensing facility.
TECHNICAL DATA
Power
220 VAC ± 10%,, 50 Hz.
Wire size: 1.5 Sq. mm with 600V insulation
RE - 120GR
Remote Outputs
Fire Contact (C, NO, NC) : 220v AC/30v DC@ 1A
Fault Contact (C, NO, NC ): 220v AC/30v DC@ 1A
Timer Contact (C, NO, NC): 220v AC/30v DC@ 1A
Battery (Lead Acid only)
24 VDC Power For remote devices
Charging Voltage
: 27.9 VDC.
Operating Voltage: 24VDC, 500mA Max.
Charging Capacity
: 7 Amp Hour Battery Max.
System Quiescent Current: 80mA + (2.4mA for Detector s) RS 24 VDC Power For Four Wire devices
Operating Voltage: 24VDC, 500mA Max.
Initiating Device Circuits (Zone Circuit)
All zones are Class B wiring
Dimension of the panel :
Normal Operating Voltage : Nominal 24 VDC
400 x 300 x 100 mm ( length x height x width )
Alarm Current
: 15 - 35mA threshold
Short Circuit Current
: 40mA Maximum
Loop resistance
: 50 ohms Maximum
End-Of-Line Resistor
: 4.7K, 1/4watt
Standby Current
: 6.8mA (2.4mA for Detectors)
Notification Appliance Circuits (Sounder/Hooter Circuit)
Operating Nominal Voltage: 24 VDC
Hooter (NACs) output
: 0.5A (Each)
End-Of-Line Resistor
: 4.7K, 1/4watt
Solenoid Relay Output Circuits
Operating Nominal Voltage : 24 VDC
Solenoid output
: 0.75A (Each)
2No’s of Hooter (NACs) output : 0.3A (Each)
End-Of-Line Resistor: 4.7K, 1/4watt (for Solenoid Output)
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
FEATURES:
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
RE - 150D
Fully confirms IS 2189: 1988
16SWG Rugged CRCA with powder coated finish.
Modular construction.
Operates on 230V, A.C supply.
Battery backup with built in charging.
16x2 LCD Dot matrix Display.
Fire / Fault status in unambiguous coloured LED
indication.
Low battery / battery fail warning audio / visual
indication.
A.C fail audio / visual warning.
Charger fail audio / visual warning
System on, AC on, Battery on & Charger on indications
Potential Free Relay Contacts for actuators.
Lamp test facility.
One man walk test facility.
Compatible to all types of conventional detectors.
Twin RED LED indication for fire.
Zone Isolation facility with loop voltage cut off.
Earth Fault with Audio and Visual Indications.
Supervised Sounder 24v DC output for External
notification devices (Sounder, Bell, etc.).
1.
TECHNICAL DATA
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Power Supply:
AC Input Supply
DC Input Supply
2. Operating Conditions
3. Operating Voltage
4. Normal Loop Voltage
5. Open Threshold Current
6. Short Circuit Threshold Current
7. Stand by Threshold Current
( EOL Current + detector's Current)
8. Alarm Current
9. Quiescent Current
10. Colour of the Panel
11.
12.
ALARM OUTPUT:
Standard Common Output
:
:
:
:
:
:
:
:
230 V AC, 50Hz
24 V DC
o
-10 to 45 C, 95 % RH Max.
24 V DC
20.7 DC
4.2 mA
40 mA
8.2 mA
:
:
:
20 - 35 mA
50mA Plus 4.2mA per Zone
Semains Gray (Red, Red Texture - Optional)
:
0.2A per Zone.
REMOTE INDICATION OUTPUTS:
Outputs
:
Fire Relay Contacts (230 V 2A contact).
MOUNTING DETAIL
TERMINAL DETAILS UPTO 8 ZONE
TERMINAL DETAILS ABOVE 8 ZONE
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
FEATURES:
# Fully complies with IS 2189: 1988.
# Rugged CRCA sheet with powder coated finish.
# 20 X 4 LCD Dot Matrix Display.
# 12 - 128 Class B initiating device circuit (IDC / Zone Circuits).
# One Class B Notification Appliance Circuits (NAC / Sounder).
# Low Battery / Warning audio / Visual Display.
# Operates on 220v, AC Mains power supply.
# Standby (battery) back up 24v DC power supply with built in charger
# Error free Fire / Fault status in unambiguous colored LED indication.
# Main, Standby status with visual/audible indication.
# Battery Low visual warning with audible tone.
# Event storage with RTC.
# Form C relays for Fire and fault.
# RS 485 and RS 232 Communication Facility.
# TCP/IP (Optional) facility.
# Walk Test facility.
# Zone Isolation facility with loop voltage cut off.
# Compatible with all types of conventional detectors, Pull Stations and
RE - 700
any normally open contact devices.
TECHNICAL DATA
1.
Power Supply:
AC Input Supply
DC Input Supply
2. Operating Conditions
3. Operating Voltage
4. Normal Loop Voltage
5. Open Threshold Current
6. Short Circuit Threshold Current
7. Stand by Threshold Current
( EOL Current + detector's Current)
8. Alarm Current
9. Quiescent Current
10. Colour of the Panel
11.
12.
ALARM OUTPUT:
Standard Common Output
:
:
:
:
:
:
:
:
230 V AC, 50Hz
24 V DC
-10 to 45 oC, 95 % RH Max.
24 V DC
20.7 DC
4.2 mA
40 mA
8.2 mA
:
:
:
20 - 35 mA
50mA Plus 4.2mA per Zone
Broken White (Red, Red Texure - Optional)
:
0.2A per Zone.
REMOTE INDICATION OUTPUTS:
Outputs
:
Fire,Fault Relay Contacts (230 V 2A contact).
RAVEL ELECTRONICS PVT. LTD.,
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
FEATURES
RE - 2504
RE - 2508
¥ Fully complies with UL -864 and NFPA-72.
¥ Rugged CRCA sheet with powder coated finish.
¥ Operates on 220v 50Hz, AC Mains power supply.4/8 Class B initiating
device circuit (IDC).
Ø All zones accept smoke detectors and any normally open contact
device.
Ø Any Zone can be configured as Alarm or supervisory Zone.
¥ 2 Class B Notification Appliance Circuits (NAC).
¥ Standby (battery) backup 24v DC power supply with built in charger.
¥ Error free Fire / Fault status in unambiguous colored LED indication.
¥ Main, Standby status audible and visual indication.
¥ Battery Low visual warning with audible tone.
¥ Form-C relays for fire, fault and supervisory.
¥ Zone Isolation facility with loop voltage cut off.
¥ Ground fault annunciation facility at 0 ohms.
¥ All field wiring circuits are Power limited except 220v A.C. and Battery.
¥ All field wiring circuits are supervised.
¥ AC Low voltage cutoff.
¥ Programmable NAC's.
¥ Programmable IDC’s.
¥ Programmable AC loss delay.
Primary Power CN1 (RE-SMPS-4A-R1)
220VAC ± 10%, 50 Hz, 2.5Amps.
Standby Power CN10
24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery).
Operating Temperature
Operating Temperature 15 - 35° C/60-95° F.
Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F.
TECHNICAL DATA
Charging Circuit
Charging Voltage 28.4V, ±0.2V
Charging Current 750mA (Max.).
Initiating Device Circuits CN 8
All zones are Class B Style B/C operation (Programmable).
Normal Operating Voltage: 14 - 21 VDC.
Alarm Current: 15 30mA.
Short Circuit Current: 40mA Maximum.
Loop resistance: 100 ohms Maximum.
End-Of-Line Resistor: 3K9, 1/2watt
Standby Current: 7mA (2mA for Detectors)
Notification Appliance Circuits CN5 and Cn6
Class B Style - Y wiring
Operating Nominal Voltage: 24VDC Special Application
Current for all NACs: 1.2Amps (0.6A per circuit)
Current Limit: CN5 and CN6 via Thermal Fuse
Line Drop: 1.8V
End-Of-Line Resistor: 3K9, 1/2watt
Note: For compatible devices refer Manual(CD 01).
Resettable D.C. Power CN7
Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4
wire smoke detector)
Common Three Form C Relays CN2, CN3, CN4
Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC.
Power Factor: 0.6
Ordering Information
RE 2504 W/R
W- White Colour; R - Red Colour.
RE 2508 W/R
W- White Colour; R - Red Colour.
Dimension of the panel : 440 x 340 x 120 mm ( length x height x width )
150-A, ELECTRONICS INDUSTRIAL ESTATE,
PERUNGUDI, CHENNAI - 600 096. INDIA.
Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599.
E-Mail: [email protected]
URL: www.ravelfirepanels.com
RE - RP
FEATURES:
!
!
!
!
CRCA sheet with powder coated finish.
Operates on 24 VDC.
Fire / Fault status in unambiguous coloured LED
indication.
System on indications
Silence facility.
Lamp test facility.
RS485 for Repeater Communication (Use shielded
or twisted wire (CAT5E or CAT6)).
TECHNICAL DATA
!
!
!
1.
2.
3.
4.
5.
Operating Voltage
Operating Conditions
Operating Current
Quiescent Current
Colour of the Panel
ALARM OUTPUT:
Standard Common Output
:
:
:
:
:
24VDC
o
-10 to 45 C, 95 % RH Max.
20 - 35 mA
50mA Plus 0.125mA per Zone
Broken White (Red, Red Texure - Optional)
:
0.2Amps.

advertisement