Ravel | RE-2508 | User manual | RE - Master TECHNICAL D ATA TERMINAL DETAIL
Add to my manuals18 Pages
advertisement
▼
Scroll to page 2
of 18
150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com FEATURES: Fully confirms IS 2189: 1988 Rugged CRCA with powder coated finish. Operates on 230V, A.C supply. Battery backup with built in charging. Error free fire / fault status in unambiguous coloured LED Indication. 20 X 4 LCD Dot Matrix display. Low battery / warning audio/ visual display. Battery fail warning audio Charger on indication. A.C fail audio / visual warning. Relay output for actuators. Up to 256 Zones( Panel Availability for 64/128/256). RS485 for repeater/slave communication Shielded or twisted wire (CAT5E or CAT6). Slave panel Compatible only with RE 2554/RE2558 . Slave Isolation facility. Events Memory with RTC. RS 232 facility. Ethernet Module (RJ45) Facility. (Optional) Dimension of the panel : 350 x 300 x 100 mm(l x h x d) TECHNICAL DATA 1. 2. 3. 4. 5. 2. 3. RE - Master Power Supply: AC Input Supply DC Input Supply Operating Conditions Operating Voltage Charging Current Colour of the Panel : : : : : : 230 V AC, 50Hz 24 V DC o -10 to 45 C, 95 % RH Max. 24 V DC 27.4 VDC. Broken White (Red, Red Texure - Optional) SOUNDER OUTPUT: Standard Common Output : 2Amps . REMOTE INDICATION OUTPUTS: Outputs : Fire Relay Contacts (2No’s of 230 V 2A contact). Fault Relay Output (1 No. of 230 V 2A contact) TERMINAL DETAIL ANALOG ADDRESSABLE FIRE ALARM PANEL Avani By FEATURES Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø As per UL 864, 9th Edition & NFPA 72. 32 bit processor - Arm Cortex M3. Operates on 120 to 220V AC, 60 / 50 Hz. Battery Backup 24V DC with Built in charger. 40 x 4 Characters LCD display. Touch key pad for user friendly operation. Maximum 4 number of loop cards with Class A or B wiring. Maximum 198 devices (99 Detectors + 99 Modules) per loop. Upto 192 Grouping Facility. Auto Learning facility. Device / Detector wise Configuration facility. Auto device type verification. Programmable Detector sensitivity. 2000 Event storage with Real Time Clock. Day / Night Mode Facility. USB 2.0 Interface for PC connectivity. RS 485 Communication facility for Network / Repeater. Auto dialer / GSM Module (Optional). Ethernet Module (Optional). Printer Interface Module (Optional). Programmable Auto Silence Facility. Programmable Trouble Reminder Facility. Programmable AC Loss Delay. Programmable Silence Inhibit. Loop wise test facility. Battery low visual warning with audible tone. Three Programmable Form C relay for Fire, Fault and supervisory. Supervised 24V DC output. Two nos. of Supervised Notification Appliance Circuits. SPECIFICATION Primary Power 120 / 220VAC + 10% -15%, 60 / 50 Hz. Standby Power 24V D.C (2 Nos of 12v, 14Ah ) Sealed Lead acid battery Operating Condition Operating Temperature 0 - 49° C/32-120° F. Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/96 ±3° F. Charging Circuit Charging Voltage 28 V, ±0.2V Nominal Charging Current 1.2A (Max.). Signaling Line Circuits Class A or B loop card: 4 Nos. Maximum. No of Device per loop: 198 (99 Detectors + 99 Modules System Sensor). Multi protocol devices per loop : 254. Loop resistance: 40 ohms (Max.). Loop capacitance: 0.6 µf (Max.). Loop Current: 300mA (Max.). Initiating Device Circuits One conventional zone Class B Style B/C operation. Normal Operating Voltage: 14 - 21 VDC. Alarm Current: 15 - 30mA. Short Circuit Current: 45mA Maximum. Loop resistance: 100 ohms Maximum. End-Of-Line Resistor: 4K7, 1/2watt Standby Current: 7mA (2mA for Detectors) Programmable Input Circuits No. of Inputs: 1 Normal Operating Voltage: 4 - 8 VDC. Short Circuit Current: 3mA Maximum. Loop resistance: 100 ohms Maximum. End-Of-Line Resistor: 4K7, 1/2watt Standby Current: 1.25mA Notification Appliance Circuits Class B, Style - Y wiring Operating Nominal Voltage: 24 VDC Nominal Current for NACs: 2Amps (1A per circuit) Line Drop: 2.4V End-Of-Line Resistor: 4K7, ½ watt D.C. Output Supervised 24VDC, 300mA Max. Three Programmable Form C Relays Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. Power Factor: 0.6 Avani By ANALOG ADDRESSABLE FIRE ALARM REPEATER PANEL FEATURES Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø As per UL 864, 9th Edition & NFPA 72. Operates on 120 to 220V AC, 60 / 50 Hz. Battery Backup 24V DC with Built in charger. 32 bit processor - Arm Cortex M3. 40 X 4 Characters LCD display. Touch key pad for user friendly operation. Remote silence, reset and evacuate can be done from repeater panel. Repeats all the indication / Information of main panel. All programming of the main panel can be done from the Repeater Panel. RS 485 Communication for Standalone / Network Repeater. 10,000 Event storage with Real Time Clock. Battery low visual warning with audible tone. One Supervised Notification Appliance Circuits. One Form C relay for Common Fire. RE - 1504 CONVENTIONAL PANEL WITH ADDRESSABLE FEATURES FEATURES ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ ¥ RE - 1508 As per NFPA-72 standards. Rugged CRCA sheet with powder coated finish. Network able / Standalone panel. 4/8 Class B conventional initiating device circuit (IDC). Ø All zones accept smoke detectors and any normally open contact device. Ø Any Zone can be configured as Alarm or supervisory Zone. Class B Notification Appliance Circuits (NAC). Operates on 220v 50Hz, AC Mains power supply Standby (battery) backup 24v DC power supply with built in charger. All field wiring circuits are supervised. AC Low voltage cutoff. Programmable NAC. Programmable IDCs. Programmable AC loss delay. Programmable Trouble reminder. Programmable Form -C relay for fire / Fault / Supervisory. 2 Form-C relay for Fire. Alarm Verification Facility. ** 1000 history events with RTC. Error free Fire / Fault status in unambiguous colored LED indication. Main, Standby status audible and visual indication. Battery Low visual warning with audible tone. Zone Isolation Facility. Peer to Peer networking facility (upto 16 panels ) . Ground fault annunciation facility at 0 ohms. All field wiring circuits are Power limited except 220v A.C. and Battery. Advanced features for the System Sensor series 300 detectors. ª 32 Detectors per Zone. ª Active Scan Devices facility. ª Individual detector address with location. ** - This facility is available only in system sensor 300 series protocol disable condition. Primary Power 220VAC ± 10%, 50 Hz, 2.5Amps. Standby Power 24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery). Operating Condition Operating Temperature 15 - 35° C/60-95° F. Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F. Technical Specification Charging Circuit Charging Voltage 28.4V, ±0.2V Charging Current 800mA (Max.). Initiating Device Circuits All zones are Class B Style C operation. Normal Operating Voltage: 14 - 20 VDC. Alarm Current: 15 - 30mA. Short Circuit Current: 40mA Maximum. Loop resistance: 40 ohms Maximum. End-Of-Line Resistor: 4K7, 1/2watt Standby Current: 6mA (2mA for Detectors) Notification Appliance Circuits Class B Style - Y wiring Operating Nominal Voltage: 24VDC Special Application Current for NACs: 1Amps Line Drop: 1.8V End-Of-Line Resistor: 4K7, 1/2watt Resettable D.C. Power Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4 wire smoke detector) Common Three Form C Relays Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. Power Factor: 0.6 Ordering Information RE 1504 W/R 4 IDC RE 1508 W/R 8 IDC W- White Colour; R - Red Colour. Dimension of panel : 425 X 350 X 110mm ( Width x Height X Depth) Ravel Electronics Pvt. Ltd. 150A, Electronic Industrial Estate, Perungudi, Chennai - 96. India. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599 Mail: [email protected] URL: www.ravelfirepanels.com RE - 2554 RE - 2558 FEATURES Fully complies with UL -864 and NFPA-72. Rugged CRCA sheet with powder coated finish. Operates on 120 - 220v 50 /60 Hz, AC Mains power supply. 16x2 Dot Matrix LCD Display. 4/8 Class B initiating device circuit (IDC). All zones accept smoke detectors and any normally open contact device. Any Zone can be configured as Alarm or supervisory Zone. 2 Class B Notification Appliance Circuits (NAC). Standby (battery) backup 24v DC power supply with built in charger Error free Fire / Fault status in unambiguous colored LED indication. System ON indication. Main, Standby status audible and visual indication. Battery Low visual warning with audible tone. FormC relays for fire, fault and supervisory. Resettable / uninterrupted 24v D.C. Output. RS 485 Communication facility (Optional). Lamp Test facility. Walk Test facility. Zone Isolation facility with loop voltage cut off. Earth fault annunciation facility at 0 ohms. All field wiring circuits are Power limited except 120 - 220v AC and Battery. All field wiring circuits are supervised. AC Low voltage cutoff. Programmable NAC's. Programmable IDC's. Programmable Supervisory Mode. Programmable AC loss delay. Alarm verification facility. Programmable Trouble reminder facility. RE 2554-58 SPECIFICATION Primary Power CN1 (RE-SMPS-4A-R1) 120 - 220VAC ± 10%, 50 Hz, 2.5Amps. Standby Power CN10 24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery). Operating Condition Operating Temperature 0 - 49° C/32-120° F. Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F. Charging Circuit Charging Voltage 28.2V, ±0.5V Charging Current 800mA (Max.). Initiating Device Circuits CN 8 All zones are Class B Style B/C operation (Programmable). Normal Operating Voltage: 14 - 21 VDC. Alarm Current: 15 30mA. Short Circuit Current: 45mA Maximum. Loop resistance: 100 ohms Maximum. End-Of-Line Resistor: 3K9, 1/2watt Standby Current: 7mA (2mA for Detectors) Notification Appliance Circuits CN5 and CN6 Class B Style - Y wiring Operating Nominal Voltage: 24VDC Special Application Current for all NACs: 1.2Amps (0.6A per circuit) Current Limit: CN5 and CN6 via Thermal Fuse Line Drop: 1.8V End-Of-Line Resistor: 3K9, 1/2watt Note: For compatible devices refer Chapter 9(CD 01). D.C. Power CN7 Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4 wire smoke detector) Common Three Form C Relays CN2, CN3, CN4 Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. Power Factor: 0.6 Dimension of the Panel : 440 x 340 x 120 mm ( length x height x width ) RAVEL ELECTRONICS PVT LTD., 150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com FEATURES: RE 102 F F F F Rugged CRCA sheet with powder coated finish. F F F F F F F F F F Switch Mode Power Supply. Operates on 220v, 50Hz AC supply. Standby battery back up with built in charging. Fire / Fault status in unambiguous colored LED indication. Tactile key pad for easy panel operation. System on indication. Main, Standby status indication. Low Battery visual warning with audible tone. Relay output for actuators for Fire and Fault. Lamp Test facility. Zone wise one man Walk Test facility. Zone wise Isolation facility with loop voltage cut off. Compatible to all types of conventional detectors. TECHNICAL DATA 1. Power Supply: AC Input Supply DC Input Supply 2. Operating Conditions 3. Operating Voltage 4. Normal Loop Voltage 5. Open Threshold Current 6. Short Circuit Threshold Current 7. Stand by Threshold Current ( EOL Current + detector's Current) 8. Alarm Current 9. Quiescent Current 10. Colour of the Panel 11. Panel Size 12. Approximate Weight 13. 14. ALARM OUTPUT: Common Hooter Output REMOTE OUTPUTS: Outputs : : : : : : : : : 220 V AC, 50Hz 24 V DC o -10 to 45 C, 95 % RH Max. 24 V DC 20.7 DC 4.2 mA 40 mA 8.2 mA : : : : : 20 - 35 mA 60mA Broken White (Red, Red Texure - Optional) 350 X 250 X 100(Width X Height X Depth) 4Kgs. : 24V@1A. Fire, Fault Relay Contacts (30V AC/ DC @ 2A contact). RAVEL ELECTRONICS PVT LTD., 150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com FEATURES: RE 104 F F F F Rugged CRCA sheet with powder coated finish. F F F F F F F F F F Switch Mode Power Supply. Operates on 220v, 50Hz AC supply. Standby battery back up with built in charging. Fire / Fault status in unambiguous colored LED indication. Tactile key pad for easy panel operation. System on indication. Main, Standby status indication. Low Battery visual warning with audible tone. Relay output for actuators for Fire and Fault. Lamp Test facility. Zone wise one man Walk Test facility. Zone wise Isolation facility with loop voltage cut off. Compatible to all types of conventional detectors. TECHNICAL DATA 1. Power Supply: AC Input Supply DC Input Supply 2. Operating Conditions 3. Operating Voltage 4. Normal Loop Voltage 5. Open Threshold Current 6. Short Circuit Threshold Current 7. Stand by Threshold Current ( EOL Current + detector's Current) 8. Alarm Current 9. Quiescent Current 10. Colour of the Panel 11. Panel Size 12. Approximate Weight 13. 14. ALARM OUTPUT: Common Hooter Output REMOTE OUTPUTS: Outputs : : : : : : : : : 220 V AC, 50Hz 24 V DC o -10 to 45 C, 95 % RH Max. 24 V DC 20.7 DC 4.2 mA 40 mA 8.2 mA : : : : : 20 - 35 mA 60mA Broken White (Red, Red Texure - Optional) 350 X 250 X 100(Width X Height X Depth) 4Kgs. : 24V@1A. Fire, Fault Relay Contacts (30V AC/ DC @ 2A contact). RAVEL ELECTRONICS PVT. LTD., 150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com FEATURES: Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Rugged CRCA sheet with powder coated finish. Operates on 220V, A.C supply Battery backup with built in charging. 16 X 2 LCD Dot Matrix Display. Evacuate and Key pad Enable, Disable Facility. Low battery visual warning with audible tone. 2 Form C Relay output for fire. One Programmable relay for fire/fault/solenoid on /timer on. Remote fire indication with Audible Tone. Compatible to all types of conventional detectors. Zone Disable (Isolation) facility with loop voltage cut off. Resettable 24v DC output for 4 wire detectors . Three 24V Hooter Output (Fire, after Cross zone, after gas release) . Two mode operation facility (Auto / Manual). Programmable FAP input selection Facility. Programmable Solenoid Output with On and OFF Timer. Main / Standby Cylinder output Facility . Gas Inhibition and Instant release facility. Manual Gas Release with or without timer. Actuator pressure low sensing facility. TECHNICAL DATA Power 220 VAC ± 10%,, 50 Hz. Wire size: 1.5 Sq. mm with 600V insulation RE - 120GR Remote Outputs Fire Contact (C, NO, NC) : 220v AC/30v DC@ 1A Fault Contact (C, NO, NC ): 220v AC/30v DC@ 1A Timer Contact (C, NO, NC): 220v AC/30v DC@ 1A Battery (Lead Acid only) 24 VDC Power For remote devices Charging Voltage : 27.9 VDC. Operating Voltage: 24VDC, 500mA Max. Charging Capacity : 7 Amp Hour Battery Max. System Quiescent Current: 80mA + (2.4mA for Detector s) RS 24 VDC Power For Four Wire devices Operating Voltage: 24VDC, 500mA Max. Initiating Device Circuits (Zone Circuit) All zones are Class B wiring Dimension of the panel : Normal Operating Voltage : Nominal 24 VDC 400 x 300 x 100 mm ( length x height x width ) Alarm Current : 15 - 35mA threshold Short Circuit Current : 40mA Maximum Loop resistance : 50 ohms Maximum End-Of-Line Resistor : 4.7K, 1/4watt Standby Current : 6.8mA (2.4mA for Detectors) Notification Appliance Circuits (Sounder/Hooter Circuit) Operating Nominal Voltage: 24 VDC Hooter (NACs) output : 0.5A (Each) End-Of-Line Resistor : 4.7K, 1/4watt Solenoid Relay Output Circuits Operating Nominal Voltage : 24 VDC Solenoid output : 0.75A (Each) 2No’s of Hooter (NACs) output : 0.3A (Each) End-Of-Line Resistor: 4.7K, 1/4watt (for Solenoid Output) 150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com FEATURES: Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø RE - 150D Fully confirms IS 2189: 1988 16SWG Rugged CRCA with powder coated finish. Modular construction. Operates on 230V, A.C supply. Battery backup with built in charging. 16x2 LCD Dot matrix Display. Fire / Fault status in unambiguous coloured LED indication. Low battery / battery fail warning audio / visual indication. A.C fail audio / visual warning. Charger fail audio / visual warning System on, AC on, Battery on & Charger on indications Potential Free Relay Contacts for actuators. Lamp test facility. One man walk test facility. Compatible to all types of conventional detectors. Twin RED LED indication for fire. Zone Isolation facility with loop voltage cut off. Earth Fault with Audio and Visual Indications. Supervised Sounder 24v DC output for External notification devices (Sounder, Bell, etc.). 1. TECHNICAL DATA Ø Ø Ø Ø Ø Ø Ø Power Supply: AC Input Supply DC Input Supply 2. Operating Conditions 3. Operating Voltage 4. Normal Loop Voltage 5. Open Threshold Current 6. Short Circuit Threshold Current 7. Stand by Threshold Current ( EOL Current + detector's Current) 8. Alarm Current 9. Quiescent Current 10. Colour of the Panel 11. 12. ALARM OUTPUT: Standard Common Output : : : : : : : : 230 V AC, 50Hz 24 V DC o -10 to 45 C, 95 % RH Max. 24 V DC 20.7 DC 4.2 mA 40 mA 8.2 mA : : : 20 - 35 mA 50mA Plus 4.2mA per Zone Semains Gray (Red, Red Texture - Optional) : 0.2A per Zone. REMOTE INDICATION OUTPUTS: Outputs : Fire Relay Contacts (230 V 2A contact). MOUNTING DETAIL TERMINAL DETAILS UPTO 8 ZONE TERMINAL DETAILS ABOVE 8 ZONE 150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com FEATURES: # Fully complies with IS 2189: 1988. # Rugged CRCA sheet with powder coated finish. # 20 X 4 LCD Dot Matrix Display. # 12 - 128 Class B initiating device circuit (IDC / Zone Circuits). # One Class B Notification Appliance Circuits (NAC / Sounder). # Low Battery / Warning audio / Visual Display. # Operates on 220v, AC Mains power supply. # Standby (battery) back up 24v DC power supply with built in charger # Error free Fire / Fault status in unambiguous colored LED indication. # Main, Standby status with visual/audible indication. # Battery Low visual warning with audible tone. # Event storage with RTC. # Form C relays for Fire and fault. # RS 485 and RS 232 Communication Facility. # TCP/IP (Optional) facility. # Walk Test facility. # Zone Isolation facility with loop voltage cut off. # Compatible with all types of conventional detectors, Pull Stations and RE - 700 any normally open contact devices. TECHNICAL DATA 1. Power Supply: AC Input Supply DC Input Supply 2. Operating Conditions 3. Operating Voltage 4. Normal Loop Voltage 5. Open Threshold Current 6. Short Circuit Threshold Current 7. Stand by Threshold Current ( EOL Current + detector's Current) 8. Alarm Current 9. Quiescent Current 10. Colour of the Panel 11. 12. ALARM OUTPUT: Standard Common Output : : : : : : : : 230 V AC, 50Hz 24 V DC -10 to 45 oC, 95 % RH Max. 24 V DC 20.7 DC 4.2 mA 40 mA 8.2 mA : : : 20 - 35 mA 50mA Plus 4.2mA per Zone Broken White (Red, Red Texure - Optional) : 0.2A per Zone. REMOTE INDICATION OUTPUTS: Outputs : Fire,Fault Relay Contacts (230 V 2A contact). RAVEL ELECTRONICS PVT. LTD., 150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com FEATURES RE - 2504 RE - 2508 ¥ Fully complies with UL -864 and NFPA-72. ¥ Rugged CRCA sheet with powder coated finish. ¥ Operates on 220v 50Hz, AC Mains power supply.4/8 Class B initiating device circuit (IDC). Ø All zones accept smoke detectors and any normally open contact device. Ø Any Zone can be configured as Alarm or supervisory Zone. ¥ 2 Class B Notification Appliance Circuits (NAC). ¥ Standby (battery) backup 24v DC power supply with built in charger. ¥ Error free Fire / Fault status in unambiguous colored LED indication. ¥ Main, Standby status audible and visual indication. ¥ Battery Low visual warning with audible tone. ¥ Form-C relays for fire, fault and supervisory. ¥ Zone Isolation facility with loop voltage cut off. ¥ Ground fault annunciation facility at 0 ohms. ¥ All field wiring circuits are Power limited except 220v A.C. and Battery. ¥ All field wiring circuits are supervised. ¥ AC Low voltage cutoff. ¥ Programmable NAC's. ¥ Programmable IDC’s. ¥ Programmable AC loss delay. Primary Power CN1 (RE-SMPS-4A-R1) 220VAC ± 10%, 50 Hz, 2.5Amps. Standby Power CN10 24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery). Operating Temperature Operating Temperature 15 - 35° C/60-95° F. Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F. TECHNICAL DATA Charging Circuit Charging Voltage 28.4V, ±0.2V Charging Current 750mA (Max.). Initiating Device Circuits CN 8 All zones are Class B Style B/C operation (Programmable). Normal Operating Voltage: 14 - 21 VDC. Alarm Current: 15 30mA. Short Circuit Current: 40mA Maximum. Loop resistance: 100 ohms Maximum. End-Of-Line Resistor: 3K9, 1/2watt Standby Current: 7mA (2mA for Detectors) Notification Appliance Circuits CN5 and Cn6 Class B Style - Y wiring Operating Nominal Voltage: 24VDC Special Application Current for all NACs: 1.2Amps (0.6A per circuit) Current Limit: CN5 and CN6 via Thermal Fuse Line Drop: 1.8V End-Of-Line Resistor: 3K9, 1/2watt Note: For compatible devices refer Manual(CD 01). Resettable D.C. Power CN7 Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4 wire smoke detector) Common Three Form C Relays CN2, CN3, CN4 Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. Power Factor: 0.6 Ordering Information RE 2504 W/R W- White Colour; R - Red Colour. RE 2508 W/R W- White Colour; R - Red Colour. Dimension of the panel : 440 x 340 x 120 mm ( length x height x width ) 150-A, ELECTRONICS INDUSTRIAL ESTATE, PERUNGUDI, CHENNAI - 600 096. INDIA. Ph.: +91-44-2496 1004 / 0825. Fax: +91-44-4204 9599. E-Mail: [email protected] URL: www.ravelfirepanels.com RE - RP FEATURES: ! ! ! ! CRCA sheet with powder coated finish. Operates on 24 VDC. Fire / Fault status in unambiguous coloured LED indication. System on indications Silence facility. Lamp test facility. RS485 for Repeater Communication (Use shielded or twisted wire (CAT5E or CAT6)). TECHNICAL DATA ! ! ! 1. 2. 3. 4. 5. Operating Voltage Operating Conditions Operating Current Quiescent Current Colour of the Panel ALARM OUTPUT: Standard Common Output : : : : : 24VDC o -10 to 45 C, 95 % RH Max. 20 - 35 mA 50mA Plus 0.125mA per Zone Broken White (Red, Red Texure - Optional) : 0.2Amps.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project