- Home
- Home security & automation
- Security access control systems
- Response Electronics
- miGuard A1R
- Instructions manual
Response Electronics miGuard A1R Instructions Manual
Add to my manuals
8 Pages
Response Electronics miGuard A1R offers comprehensive home security with smart features to keep your property safe. The solar-powered siren with strobe light deters intruders, while PIR motion sensors with pet immunity and door/window sensors provide reliable detection. Arm and disarm the system or trigger an SOS alarm with the included remote control. The easy-to-install system sends low battery alerts for the sensors and the remote, ensuring uninterrupted protection. Enjoy peace of mind with miGuard A1R safeguarding your home.
advertisement
Wireless Solar Siren Alarm System
Solar Siren, PIR Motion Sensor, Door/Window
Magnetic Sensor, Remote Control
A1R
INSTRUCTIONS
miGuard Customer Helpline
0345 257 1000
“ whatever your question, we’re just a phone call away “ lines open 0900 to 1700 Monday to Friday
Congratulations on your purchase of the miGuard Solar Siren Alarm System
PCB Layout
PACK CONTENTS
1 x Solar Siren
1 x Pet Friendly PIR Motion Sensor
1 x Door/Window Magnetic Sensor
1 x Remote Control
All Batteries and Fixings
Instructions
Before Installation: a. Read the instructions thoroughly b. Remove all the contents from their packaging c. Consider the most appropriate positioning of each Accessory d. Avoid mounting Sensors near metal objects or electrical wiring.
1. PIR MOTION SENSOR
Features
Two Lens PIR : pet tolerant to 25 kgs, with a vertical and horizontal detection range of 110 °
Digital dual-core fuzzy logic control chip and intelligent analysis: effectively identifies signal interference and body movement.
Infrared Sensor: Detects movement and triggers alarm signal when the system is armed.
Tamper Switch: If the casing is opened when in
‘working state’ the tamper switch will be triggered and generate an alarm signal.
Test Mode
1. Remove the activation strip. Fit the retaining screw supplied.
2. Self-testing will commence for 1 minute, indicated by the LED flashing every 2 seconds.
3.
To enter Test Mode press the Test Button at the back of the PIR. The LED will then flash once when movement is detected, for up to 3 minutes.
Automatic temperature compensation and anti-air turbulence technology/control: automatically adapts to environmental changes, thereby saving energy.
Test Button
Automatic SMS notification of a low battery condition when connected to a miGuard GSM Alarm System.
Appearance
1.Detection Window
2.LED Indicator
3.Adjustable Bracket
Working Mode
1. To test in Working Mode, walk in front of the Sensor
- the LED should illuminate once when movement is detected.
3 2.
If the Sensor is triggered twice in 3 minutes it will enter into power saving (sleep mode). If no movement is detected within the next 3 minutes, the Sensor will return to normal working mode.
Installation
LED Indication
Flashes every 2 seconds: self-testing state
Flashes twice: self-testing finished, enters working mode
Flashes once: movement is detected
Flashes once every 3 seconds: low battery indication
(immediate battery change recommended).
If the PIR is connected to a miGuard GSM Alarm System, an SMS alert will automatically be sent to the registered user.
Avoid mounting the Sensor in areas where draughts may be present or where the temperature may fluctuate greatly, such as near to: windows, air conditioning, heating, refrigeration units, cooking appliances and direct sunlight.
Where possible, mount the Sensor in the corner of the room so that the logical path of an intruder would cut across the fan detection pattern (see diagrams overleaf). A PIR responds more effectively to movement across the device than to movement directly towards it.
PIR Installation continued…
4. Fit the Sensor in a position that will cover your desired protection area: a. Fix the bracket to the wall with the fixings kit supplied. For optimum performance set the the height of the bracket to 2 metres above ground level.
b. Adjust angle of the PIR Sensor to cover the required detection area.
Ground
Top view
2m
Side
5. To test, walk in front of the Sensor - the LED should illuminate once when movement is detected. If the Sensor is triggered twice in 3 minutes, it will enter into power saving (sleep mode). If no movement is detected within the next 3 minutes, the Sensor will return to normal working mode.
Specification
Power Supply DC 3V (AA 1.5V LR6 Battery x 2)
Static Current
Alarm Current
≤ 90uA
≤ 9.5mA
8m/110° Detection Area
Transmitting Distance ≤80m ﴾in open area﴿
Pet Immunity
Radio Frequency
≤ 25kg
433 MHz
ABS Plastic Housing Material
Operating Temperature -10°C~50°C
Relative Humidity
PIR Sensor Dimensions
(L x W x D)
Bracket Dimensions
(L x W x D)
≤ 80% ﴾non‐condensing﴿
108 x 52 x 36.8 mm
52 x 30 x 26.5 mm
2. DOOR/WINDOW SENSOR
Features
The Sensor can be fitted to doors, windows, and any other object that opens and closes.
Transmits a signal to the Control Panel/Siren when contact is broken.
Appearance & PCB Layout
LED
Transmitter Magnet
Tamper
Zone
LED Indication
Flashes once: door/window opened, transmitter sends signal to the Control Panel/Siren
Flashes rapidly: low battery indication, (immediate battery change recommended)
Installation
1. Remove the activation strip from the battery compartment.
2. Remove the backing paper from one side of each double-sided adhesive strips. Fix one adhesive strip to the back of the Magnet and one to the back of the Transmitter (alternatively for permanent fixing use the screws supplied).
3. Peel off the other side of each adhesive strip.
Mount the Magnet on the door and the
Transmitter on the door frame (small triangles facing each other), with less than a 6mm separation between the two.
4. When opening the door a small red indicator lights up briefly, this indicates that the
Transmitter has sent a signal to the Control Panel.
LED
3. REMOTE CONTROL
Features
The Remote Control enables you to quickly and conveniently Arm and Disarm your Alarm System.
In the event of an emergency when in or near your property, pressing the SOS button will trigger an alarm condition on the Control Panel/Siren.
Appearance
LED Indicator
Arm
Part Arm *
(Home Mode)
Disarm
Panic
Key-ring Clasp
* Note: Part Arm Function does not work with Siren Controlled Alarm Systems
LED
LED Indication
Flashes once: transmits the signal
Low Light Level: low battery indication, (immediate battery change recommended)
Buttons/Functions
See over.
Specification
Power Supply
Static Current
DC 1.5V (AA 1.5V LR6 Battery x 1pc)
≤ 30uA
Transmitting Distance
Radio Frequency
Alarm Current
≤80m ﴾in open area﴿
433MHz
≤ 40mA
Housing Material
Operating Temperature
ABS Plastic
-10°C~55°C
Relative Humidity
Sensor Dimensions (LxWxD)
Magnet Dimensions (LxWxD)
≤ 80% ﴾non‐condensing﴿
71 x 34 x 17.5mm
51 x 12 x 13.5mm
Specification
Power Supply
Transmitting Distance
DC3V CR2025 Lithium Battery
≤80m ﴾in open area﴿
Radio Frequency 433 MHz
Housing Material ABS Plastic
Operating Temperature -10°C~50°C
Relative Humidity
Dimensions (L x W x D)
≤ 80% ﴾non‐condensing﴿
58 x 31 x 9.5mm
REMOTE CONTROL BUTTONS/FUNCTIONS
Arm Press to Arm the Control Panel/Siren and all Accessories (Full Arm)
Disarm Press to Disarm the System
SOS
Part Arm
(Home Arm)
Panic
Does not work with Siren Controlled Systems
(operational for Control Unit Systems only)
Press to activate Panic Alarm (SOS)
+
+
4. SOLAR SIREN
Mute Arm Press to Arm the System with the Solar Siren in Mute/Silent Mode
Mute Disarm Press to Disarm the System with the Solar Siren in Mute/Silent Mode
Fit the Siren to the outside of the building in a position that is clearly visible and at a height which is relatively inaccessible to an intruder.
Although the Siren is designed to work on any aspect wall, for optimum performance try to avoid fixing it to a
North facing wall, or to a wall with shadows cast by walls, trees and roof overhangs.
For optimum radio signal reception mount the Solar Siren a minimum distance of 1 metre away from any external or internal metalwork (drainpipes, gutters, radiators, etc)
Rechargeable 3.7V
1800mAh Lithium Battery
9V
Start-up
Battery
Rear Cover Tamper Socket
Inner Tamper Switch
Learn Button
Status LED Indicator *
Alarm LED Indicators
Volume Setting
High (default) Mute Low
Rear
Anti-tamper
Switch
Sirens
Siren Duration Setting
5 minutes
2 minutes
30 seconds (default)
Connecting the Wireless Accessories
Prior to installation connect the 9V Battery and press the Power on/off button
The Siren will sound and the strobe light will flash upon activation of a connected Accessory.
Disarming the System will stop the siren sounding. If not disarmed the Siren Status Indicator will flash once every 2 seconds for one hour (visual notification of an alarm event).
There is a built-in 15 second exit delay on arming the system to allow time to leave the property.
An optional 15 second entry delay is available by setting the
Sensors to Single Delay Zone.
Installation
1. Press the Learn Button (0.5 seconds), the system goes into Learn Mode after one beep is heard.
2. Press the Test Button on the additional Accessory or trigger the
Accessory once.
3. The Wireless Accessory is learned successfully after a second beep.
4. If two beeps are heard, the accessory is already linked.
5. To finish learning the Accessories, press the Learn Button again to exit Learn Mode after one beep.
Remove the fixing screw from the bottom edge of the siren housing and carefully remove the front cover.
Hold the mounting plate in position and mark the positions of the four mounting holes.
There is a Spirit Level inside the case to help ensure that the
Siren is level.
Drill four holes, fit the wall plugs, and then fit the fixing screws supplied, in the holes.
Hinge the front cover locating tabs over the top edge of the back plate and carefully push the base of the siren cover into place. Secure the siren cover in place by refitting the fixing screw in the bottom edge of the cover.
Test Mode
1. Test Mode prevents the Siren’s tamper switch from triggering an alarm during maintenance or when changing the battery.
2. When the Remote Control is connected with the Siren, press
Unlock 3 times (within 5 seconds) to enter Test Mode, the Siren will emit a long beep indicating that the system is now in Test Mode.
During this period the Siren will not alarm but will beep if the tamper switch or the connected Sensors are triggered.
3. Press Lock on the Remote Control to exit Test Mode after a short beep.
4. The System is now Armed. Press Unlock to Disarm the System.
Enter/Exit Learning Status using a connected Remote Control
1. If the Siren has been fitted as a standalone system, additional
Accessories can easily be learnt to the Siren without the need to dismount the Siren from the wall, as follows:
2. Press Unlock on the Remote Control 3 times (within 5 seconds) to enter Test Mode.
3. Press Home Arm 3 times (within 5 seconds) to enter Learn Mode.
A long beep is heard from the Siren indicating that it is in Learn
Mode. Press the Test Button on the additional Accessory or trigger the
Accessory once.
4. The Siren will beep again to indicate that the Accessory has been successfully connected with the Siren.
5. Press Lock on the Remote Control to exit Learn Mode, it will emit one beep.
6. The System is now Armed, press Unlock to Disarm the System.
Specification
Backup Power
Solar Panel Output Current
Maximum Alarm Current
Wireless Receiving Distance
Operating Temperature
Relative Humidity
Maximum Siren Volume
Standby Current
Standby Time
Wireless Receiving Frequency
Dimensions (L x W x D)
3.7V 1800mAh Rechargeable Lithium Battery
2000LUX illumination ≥ 4mA (in sunlight)
≤ 500mA
≤ 80m ﴾free space﴿
-10°C~ +55°C
≤ 80%RH ﴾non‐condensing﴿
110dB
≤ 1.mA
≤ 45 days ﴾no sunlight﴿
≤ 433 MHz
309 x 230 x 79.8 mm
GUARANTEE
The product is guaranteed for one year from the date of purchase against faulty materials and workmanship. No liability can be accepted for any problems caused by fair wear and tear, buyer’s negligence, improper fitting or use, wilful or accidental damage, or any consequential loss or damage howsoever caused. This guarantee does not affect your statutory rights and is valid for UK and EIRE only.
If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period, then please contact our Technical Support Team (contact details shown below) for product assistance. Product repair or replacement will be offered for faulty products only with our prior agreement. Should you need to return a product then:
1. Contact the Helpline on the number below to obtain a Return Authorisation Number
2. Return your product adequately packaged, ideally in its original packaging to prevent damage in transit, and include the following: a. A copy of your original invoice/receipt b. A covering letter giving your full contact details, including email address (if applicable) c. A description of the fault or problem
Disposal and Recycling
Disposal of this product is covered by the Waste Electrical or Electronic Equipment (WEEE)
Directive. It should not be disposed of with other household or commercial waste.
At the end of its useful life the packaging and product should be disposed of via a suitable recycling centre. Please contact your local authority or the retailer from where the product was purchased for information on available facilities.
Customer Helpline
0345 257 1000
“ whatever your question, we’re just a phone call away “ lines open 0900 to 1700 Monday to Friday
www.responseelectronics.com