Wireless Solar Siren Alarm System

Solar Siren, PIR Motion Sensor, Door/Window

Magnetic Sensor, Remote Control

A1R

INSTRUCTIONS

miGuard Customer Helpline

0345 257 1000

“ whatever your question, we’re just a phone call away “ lines open 0900 to 1700 Monday to Friday

Congratulations on your purchase of the miGuard Solar Siren Alarm System

PCB Layout

PACK CONTENTS

1 x Solar Siren

1 x Pet Friendly PIR Motion Sensor

1 x Door/Window Magnetic Sensor

1 x Remote Control

All Batteries and Fixings

Instructions

Before Installation: a. Read the instructions thoroughly b. Remove all the contents from their packaging c. Consider the most appropriate positioning of each Accessory d. Avoid mounting Sensors near metal objects or electrical wiring.

1. PIR MOTION SENSOR

Features

Two Lens PIR : pet tolerant to 25 kgs, with a vertical and horizontal detection range of 110 °

Digital dual-core fuzzy logic control chip and intelligent analysis: effectively identifies signal interference and body movement.

Infrared Sensor: Detects movement and triggers alarm signal when the system is armed.

Tamper Switch: If the casing is opened when in

‘working state’ the tamper switch will be triggered and generate an alarm signal.

Test Mode

1. Remove the activation strip. Fit the retaining screw supplied.

2. Self-testing will commence for 1 minute, indicated by the LED flashing every 2 seconds.

3.

To enter Test Mode press the Test Button at the back of the PIR. The LED will then flash once when movement is detected, for up to 3 minutes.

Automatic temperature compensation and anti-air turbulence technology/control: automatically adapts to environmental changes, thereby saving energy.

Test Button

Automatic SMS notification of a low battery condition when connected to a miGuard GSM Alarm System.

Appearance

1.Detection Window

2.LED Indicator

3.Adjustable Bracket

Working Mode

1. To test in Working Mode, walk in front of the Sensor

- the LED should illuminate once when movement is detected.

3 2.

If the Sensor is triggered twice in 3 minutes it will enter into power saving (sleep mode). If no movement is detected within the next 3 minutes, the Sensor will return to normal working mode.

Installation

LED Indication

Flashes every 2 seconds: self-testing state

Flashes twice: self-testing finished, enters working mode

Flashes once: movement is detected

Flashes once every 3 seconds: low battery indication

(immediate battery change recommended).

If the PIR is connected to a miGuard GSM Alarm System, an SMS alert will automatically be sent to the registered user.

Avoid mounting the Sensor in areas where draughts may be present or where the temperature may fluctuate greatly, such as near to: windows, air conditioning, heating, refrigeration units, cooking appliances and direct sunlight.

Where possible, mount the Sensor in the corner of the room so that the logical path of an intruder would cut across the fan detection pattern (see diagrams overleaf). A PIR responds more effectively to movement across the device than to movement directly towards it.

PIR Installation continued…

4. Fit the Sensor in a position that will cover your desired protection area: a. Fix the bracket to the wall with the fixings kit supplied. For optimum performance set the the height of the bracket to 2 metres above ground level.

b. Adjust angle of the PIR Sensor to cover the required detection area.

Ground

Top view

2m

Side

5. To test, walk in front of the Sensor - the LED should illuminate once when movement is detected. If the Sensor is triggered twice in 3 minutes, it will enter into power saving (sleep mode). If no movement is detected within the next 3 minutes, the Sensor will return to normal working mode.

Specification

Power Supply DC 3V (AA 1.5V LR6 Battery x 2)

Static Current

Alarm Current

≤ 90uA

≤ 9.5mA

8m/110° Detection Area

Transmitting Distance ≤80m ﴾in open area﴿

Pet Immunity

Radio Frequency

≤ 25kg

433 MHz

ABS Plastic Housing Material

Operating Temperature -10°C~50°C

Relative Humidity

PIR Sensor Dimensions

(L x W x D)

Bracket Dimensions

(L x W x D)

≤ 80% ﴾non‐condensing﴿

108 x 52 x 36.8 mm

52 x 30 x 26.5 mm

2. DOOR/WINDOW SENSOR

Features

The Sensor can be fitted to doors, windows, and any other object that opens and closes.

Transmits a signal to the Control Panel/Siren when contact is broken.

Appearance & PCB Layout

LED

Transmitter Magnet

Tamper

Zone

LED Indication

Flashes once: door/window opened, transmitter sends signal to the Control Panel/Siren

Flashes rapidly: low battery indication, (immediate battery change recommended)

Installation

1. Remove the activation strip from the battery compartment.

2. Remove the backing paper from one side of each double-sided adhesive strips. Fix one adhesive strip to the back of the Magnet and one to the back of the Transmitter (alternatively for permanent fixing use the screws supplied).

3. Peel off the other side of each adhesive strip.

Mount the Magnet on the door and the

Transmitter on the door frame (small triangles facing each other), with less than a 6mm separation between the two.

4. When opening the door a small red indicator lights up briefly, this indicates that the

Transmitter has sent a signal to the Control Panel.

LED

3. REMOTE CONTROL

Features

The Remote Control enables you to quickly and conveniently Arm and Disarm your Alarm System.

In the event of an emergency when in or near your property, pressing the SOS button will trigger an alarm condition on the Control Panel/Siren.

Appearance

LED Indicator

Arm

Part Arm *

(Home Mode)

Disarm

Panic

Key-ring Clasp

* Note: Part Arm Function does not work with Siren Controlled Alarm Systems

LED

LED Indication

Flashes once: transmits the signal

Low Light Level: low battery indication, (immediate battery change recommended)

Buttons/Functions

See over.

Specification

Power Supply

Static Current

DC 1.5V (AA 1.5V LR6 Battery x 1pc)

≤ 30uA

Transmitting Distance

Radio Frequency

Alarm Current

≤80m ﴾in open area﴿

433MHz

≤ 40mA

Housing Material

Operating Temperature

ABS Plastic

-10°C~55°C

Relative Humidity

Sensor Dimensions (LxWxD)

Magnet Dimensions (LxWxD)

≤ 80% ﴾non‐condensing﴿

71 x 34 x 17.5mm

51 x 12 x 13.5mm

Specification

Power Supply

Transmitting Distance

DC3V CR2025 Lithium Battery

≤80m ﴾in open area﴿

Radio Frequency 433 MHz

Housing Material ABS Plastic

Operating Temperature -10°C~50°C

Relative Humidity

Dimensions (L x W x D)

≤ 80% ﴾non‐condensing﴿

58 x 31 x 9.5mm

REMOTE CONTROL BUTTONS/FUNCTIONS

Arm Press to Arm the Control Panel/Siren and all Accessories (Full Arm)

Disarm Press to Disarm the System

SOS

Part Arm

(Home Arm)

Panic

Does not work with Siren Controlled Systems

(operational for Control Unit Systems only)

Press to activate Panic Alarm (SOS)

+

+

4. SOLAR SIREN

Mute Arm Press to Arm the System with the Solar Siren in Mute/Silent Mode

Mute Disarm Press to Disarm the System with the Solar Siren in Mute/Silent Mode

Fit the Siren to the outside of the building in a position that is clearly visible and at a height which is relatively inaccessible to an intruder.

Although the Siren is designed to work on any aspect wall, for optimum performance try to avoid fixing it to a

North facing wall, or to a wall with shadows cast by walls, trees and roof overhangs.

For optimum radio signal reception mount the Solar Siren a minimum distance of 1 metre away from any external or internal metalwork (drainpipes, gutters, radiators, etc)

Rechargeable 3.7V

1800mAh Lithium Battery

9V

Start-up

Battery

Rear Cover Tamper Socket

Inner Tamper Switch

Learn Button

Status LED Indicator *

Alarm LED Indicators

Volume Setting

High (default) Mute Low

Rear

Anti-tamper

Switch

Sirens

Siren Duration Setting

5 minutes

2 minutes

30 seconds (default)

Connecting the Wireless Accessories

Prior to installation connect the 9V Battery and press the Power on/off button

The Siren will sound and the strobe light will flash upon activation of a connected Accessory.

Disarming the System will stop the siren sounding. If not disarmed the Siren Status Indicator will flash once every 2 seconds for one hour (visual notification of an alarm event).

There is a built-in 15 second exit delay on arming the system to allow time to leave the property.

An optional 15 second entry delay is available by setting the

Sensors to Single Delay Zone.

Installation

1. Press the Learn Button (0.5 seconds), the system goes into Learn Mode after one beep is heard.

2. Press the Test Button on the additional Accessory or trigger the

Accessory once.

3. The Wireless Accessory is learned successfully after a second beep.

4. If two beeps are heard, the accessory is already linked.

5. To finish learning the Accessories, press the Learn Button again to exit Learn Mode after one beep.

Remove the fixing screw from the bottom edge of the siren housing and carefully remove the front cover.

Hold the mounting plate in position and mark the positions of the four mounting holes.

There is a Spirit Level inside the case to help ensure that the

Siren is level.

Drill four holes, fit the wall plugs, and then fit the fixing screws supplied, in the holes.

Hinge the front cover locating tabs over the top edge of the back plate and carefully push the base of the siren cover into place. Secure the siren cover in place by refitting the fixing screw in the bottom edge of the cover.

Test Mode

1. Test Mode prevents the Siren’s tamper switch from triggering an alarm during maintenance or when changing the battery.

2. When the Remote Control is connected with the Siren, press

Unlock 3 times (within 5 seconds) to enter Test Mode, the Siren will emit a long beep indicating that the system is now in Test Mode.

During this period the Siren will not alarm but will beep if the tamper switch or the connected Sensors are triggered.

3. Press Lock on the Remote Control to exit Test Mode after a short beep.

4. The System is now Armed. Press Unlock to Disarm the System.

Enter/Exit Learning Status using a connected Remote Control

1. If the Siren has been fitted as a standalone system, additional

Accessories can easily be learnt to the Siren without the need to dismount the Siren from the wall, as follows:

2. Press Unlock on the Remote Control 3 times (within 5 seconds) to enter Test Mode.

3. Press Home Arm 3 times (within 5 seconds) to enter Learn Mode.

A long beep is heard from the Siren indicating that it is in Learn

Mode. Press the Test Button on the additional Accessory or trigger the

Accessory once.

4. The Siren will beep again to indicate that the Accessory has been successfully connected with the Siren.

5. Press Lock on the Remote Control to exit Learn Mode, it will emit one beep.

6. The System is now Armed, press Unlock to Disarm the System.

Specification

Backup Power

Solar Panel Output Current

Maximum Alarm Current

Wireless Receiving Distance

Operating Temperature

Relative Humidity

Maximum Siren Volume

Standby Current

Standby Time

Wireless Receiving Frequency

Dimensions (L x W x D)

3.7V 1800mAh Rechargeable Lithium Battery

2000LUX illumination ≥ 4mA (in sunlight)

≤ 500mA

≤ 80m ﴾free space﴿

-10°C~ +55°C

≤ 80%RH ﴾non‐condensing﴿

110dB

≤ 1.mA

≤ 45 days ﴾no sunlight﴿

≤ 433 MHz

309 x 230 x 79.8 mm

GUARANTEE

The product is guaranteed for one year from the date of purchase against faulty materials and workmanship. No liability can be accepted for any problems caused by fair wear and tear, buyer’s negligence, improper fitting or use, wilful or accidental damage, or any consequential loss or damage howsoever caused. This guarantee does not affect your statutory rights and is valid for UK and EIRE only.

If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period, then please contact our Technical Support Team (contact details shown below) for product assistance. Product repair or replacement will be offered for faulty products only with our prior agreement. Should you need to return a product then:

1. Contact the Helpline on the number below to obtain a Return Authorisation Number

2. Return your product adequately packaged, ideally in its original packaging to prevent damage in transit, and include the following: a. A copy of your original invoice/receipt b. A covering letter giving your full contact details, including email address (if applicable) c. A description of the fault or problem

Disposal and Recycling

Disposal of this product is covered by the Waste Electrical or Electronic Equipment (WEEE)

Directive. It should not be disposed of with other household or commercial waste.

At the end of its useful life the packaging and product should be disposed of via a suitable recycling centre. Please contact your local authority or the retailer from where the product was purchased for information on available facilities.

Customer Helpline

0345 257 1000

“ whatever your question, we’re just a phone call away “ lines open 0900 to 1700 Monday to Friday

www.responseelectronics.com

Response Electronics Limited

Roman House, Lysons Avenue, Ash Vale, Surrey, GU12 5QF email: [email protected]

miGuard is a trademark of Response Electronics Limited © copyright 2014 All rights reserved

MGA1R_V3_1526

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement