Cleveland Range 42-CKEM-24 General Manual

Add to my manuals
2 Pages

advertisement

Cleveland Range 42-CKEM-24 General Manual | Manualzz
Project ________________________________
™
Cleveland
Item __________________________________
CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
Approval _______________________________
Cleveland Classic Series
Quantity _______________________________
FCSI Section ____________________________
CONVECTION
STEAMERS
TWO COMPARTMENT, PRESSURELESS
PLUS ONE 6 GALLON KETTLE
24, 36 OR 48 KW ELECTRIC STEAM GENERATOR
42” WIDE CABINET BASE DESIGN
Date __________________________________
MODELS: 42-CKEM-24 42-CKEM-48
42-CKEM-36
Cleveland Standard Features
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans.
Pressureless cooking with forced convection steam, permitting
doors to be opened while cooking continues.
Solid State Controls operate water level and safety functions.
Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.
Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.
Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
Separate Main Power Switch for “On/Off”
Exclusive Steam Cooking Distribution System: The exclusive Convection Jets produce a high velocity convection steam
without fans. Coved Corner design in cooking compartment distributes heat evenly and is easy to keep clean. Creased top & bottom enhance drainage. Cold Water Condenser for each
compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide
Racks for easy cleaning.
Exclusive “Cool to the Touch” Compartment Door Design:
Free floating inner door with reversible door gasket provides
an air tight seal. Stainless Steel Slam/Latch Door Latch mechanism provides greater reliability.
Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
Modular Cabinet Base with Hinged Door.
Electric Steam Generator: Automatic Water Fill on start up.
Automatic Generator Drain at shutdown: Contains a “Water
Jet” Spray Rinse Cleaning Cycle to keep drain clear.
Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
Steam generator equipped with High Limit Pressure Safety Switch,
15 psi Safety Valve, and Steam Generator Pressure Gauge.
Secondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
I Standard voltage 208 or 240 volts, 60 Hz, 3 phase.
I Table Top includes 2˝ deep Drain Trough with 3⁄4˝ Drain & Grate
I 6 gallon Tilting Kettle made of type 304 Stainless Steel,
2
⁄3 jacketed
Kettle includes:
I Trunnion Mounted Steam Control Valve
I 50 psi kettle Steam Jacket Pressure Rating
I Lift Off Cover
I Double Pantry Faucet with Swing Spout
I
Shown with optional
Electronic Timer
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, plus one 6
gallon Direct Steam, tilting, kettle, Model 42-CKEM- _____ , Electric
_____ volts, _____ phase, 3 wire. Solid State Controls operate timing, water level
and safety functions. Electric Steam Generator with Automatic Water Fill on
start-up and Automatic Blowdown with additional Manual Drain Valve. For
each cooking compartment: 60 minute Mechanical Timer, Manual Operation
Mode and Cold Water Condenser. Type 304 Stainless Steel cooking compartment.
Options & Accessories
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Right Hand Door Hinging, Controls on the Left (DHR)
Electronic Timer with Compensating Load Feature (ETC)
ON/OFF Steam Switch only for compartment controls (MC)
Cafeteria pans in depths of 1˝, 21⁄2˝, 4˝ and 6˝
Compartment Door Steam Shut Off Switch (SCS)
Voltages other than standard (see back page)
Correctional Packages
Power Take Off Kit (EPTO), Kettle Interconnecting Kit (IMK)
Stainless Steel Base Frame (FSS)
Type 316 Stainless Steel Liner for high acid products (316-6G)
Boiler Descaling Pump Kit (107142)
Water Filters
SECT.
1333 East 179 St.,
Tel: 1-216-481-4900
Web Site: www.ClevelandRange.com
Cleveland, Ohio, U.S.A. 44110
Fax: 1-216-481-3782
Email: [email protected]
III
17
PAGE
0609
ACTUAL CAPACITIES:
Kettle 6 gallons/23 liters or 192, 4 oz. servings.
• Other size servings may be calculated.
Each compartment has capacity for:
• Three, 12˝ x 20˝ x 21⁄2˝ or six, 12˝ x 20˝ x 1˝
deep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated, based
upon 10 hours of use per day, and a Daily
Blowdown, are as follows:
TOTAL DISSOLVED
SOLIDS
less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on
site water analysis for recommendations concerning
steam generator feed water treatment (if required),
in order to remove or reduce harmful concentrations
of minerals. The use of highly mineralized water will
mean that more frequent servicing of the steam
generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable
for the generator.
KW Volts
24
ELECTRIC
Watts Ph Amps Wire
208
21,500
1
103.4
2
220
24,000
1
109.1
2
240
24,000
1
100.0
2
440
20,200
1
45.9
2
480
24,000
1
50.0
2
208
21,500
3
59.7
3
220
24,000
3
63.1
3
240
24,000
3
57.8
3
440
20,200
3
26.5
3
480
24,000
3
28.9
3
600
24,000
3
23.1
3
360
21,500
3
34.5
4
380
24,000
3
36.5
4
415
24,000
3
33.4
4
WATER
C
1/4˝ NPT , Cold Water
Inlet, 35 psi minimum,
60 psi maximum
1/4" NPT hot
and cold water
for swing spout
NOTES:
DRAINAGE
KW Volts Watts Ph Amps Wire
36
208 32,200 3 89.5
3
220 36,000 3 94.6
3
240 36,000 3 86.7
3
440 30,200 3 39.7
3
480 36,000 3 43.4
3
600 36,000 3 34.7
3
360 32,200 3 51.7
4
380 36,000 3 54.8
4
415 36,000 3 50.1
4
48
208 42,900 3 119.2
3
220 48,000 3 126.1
3
240 48,000 3 115.6
3
440 40,300 3 52.9
3
480 48,000 3 57.8
3
600 48,000 3 46.2
3
360 42,900 3 68.9
4
380 48,000 3 73.0
4
415 48,000 3 66.9
4
D
The Floor Drain must be located
outside the confines of the
equipment base.
1 1/2˝ I.P.S. common drain.
Do not connect other units to this drain.
Do not use PVC pipe for drain.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA.
CLEARANCE
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
acess)
Contact factory for
variances to clearances.
III
18
(NOT TO SCALE)
SECT.
PAGE
0609
Litho in U.S.A.