Specification Sheet Compact Fluorescent Program Start Series Lamp Operation escent Ballast Project:

Specification Sheet
EP2/26CF/MV/2
Electronic Fluorescent Ballast
7/21/2014
Project:
2 Lamp
Standard Ballast Factor
Multi-volt
Catalog#:
Approved by:
Compact Fluorescent Program Start Series Lamp Operation
Lamp Type
CF26DE*
CF26TE
CF32TE
CF42TE
CFQ57W/G24q
CFTR57W/GX24q
CFS21W/G24q
FT24W/2G11
FT18W/2G11
F24T5/HO
FC16T9
FC12T5
FC9T5
No. Of
Lamps
Lamp
Watts
Line
Voltage
Ballast
Factor
Input
Watts
Input
Current
(amps)
Power
Factor
THD
Ballast
Efficacy
Factor
2
2
1
1
2
2
1
1
1
1
1
1
1
1
1
1
2
2
2
2
1
1
2
2
2
2
1
1
1
1
1
1
26
26
26
26
26
26
26
26
32
32
42
42
57
57
57
57
21
21
24
24
24
24
18
18
24
24
40
40
40
40
22
22
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
1.00
1.00
1.00
1.00
1.00
1.00
1.10
1.10
0.98
0.98
0.98
0.98
0.81
0.82
0.81
0.82
1.12
1.12
0.93
0.93
0.90
0.89
0.73
0.74
1.00
1.00
1.00
1.00
0.74
0.75
1.02
1.03
51
51
27
27
54
54
29
29
36
36
46
46
52
51
52
51
51
51
48
48
26
26
33
33
51
51
43
43
34
34
27
27
0.43
0.19
0.23
0.10
0.24
0.11
0.45
0.20
0.31
0.13
0.38
0.17
0.43
0.19
0.43
0.19
0.42
0.18
0.41
0.18
0.21
0.10
0.27
0.12
0.44
0.19
0.36
0.16
0.28
0.13
0.22
0.08
0.99
0.99
0.98
0.98
0.99
0.99
0.98
0.98
0.98
0.98
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.96
0.99
0.98
0.99
0.98
0.99
0.97
0.99
0.98
0.99
0.97
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<10%
<12%
1.96
1.96
3.70
3.70
1.85
1.85
3.79
3.79
2.72
2.72
2.13
2.13
1.56
1.61
1.56
1.61
2.20
2.20
1.94
1.94
3.52
3.46
2.24
2.26
1.96
1.96
2.33
2.33
2.17
2.18
3.84
3.82
* Primary Lamp Design
Ballast Specifications
• Ballast shall have a five-year warranty with maximum case temperature of
70ºC or three-year warranty with maximum case temperature of 90ºC.
Dimensions
• Ballast shall be UL certified.
• Ballast shall be sound rated Class A.
TOP VIEW
• Ballast shall be Class P Type 1 Outdoor.
4.5
• Ballast shall have a Lamp Current Crest Factor of <1.7.
• Ballast shall withstand line transients as specified in ANSI C62.41.
• Ballast shall comply with the limits of FCC Part 18 Class B (Consumer).
HOTSPOT
2.01
• Ballast shall have a lamp operating frequency greater than 40KHz.
• Ballast shall have color-coded, dual entry poke-in connectors.
• Ballast shall ignite lamps within 900ms.
Wiring Diagram
• Ballast shall have a 0ºF minimum lamp starting temperature for primary lamp(s).
• Ballast shall be Program Start.
BLUE
BLACK
• Ballast shall be Series Lamp Operation.
BLUE
• Ballast shall have a minimum Power Factor of 97% for primary lamp operation.
YELLOW
WHITE
BALLAST YELLOW
• Ballast shall operate within a +/- 10% of the ballast specified line voltage at an
RED
input frequency of 50Hz or 60Hz.
GROUND
RED
• Ballast shall have a maximum case hot spot temperature of 90ºC.
• Ballast shall have end of lamp life protection.
• Ballast shall have auto restart.
• Specifications are subject to change without notice.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
SIDE VIEW
4.00
1.00
2.4
1 Lamp Operation
2 Lamp Operation
BLUE
BLUE
RED
RED
***Cap or remove unused Yellow Leads