BCD180 Series Datasheet

DC BATTERY
CHARGER
MODEL
BCD180 SERIES
Benefits
• Ultra-Quiet
• Power sensitive electronics without interference
• Rugged & Reliable
• Ensure years of safe and trouble free operation
• Fast & Accurate Charging
Design Features
• Input voltage range allows operation from 24 or 32 VDC. 48
and 72 VDC also available,
• Extremely rugged and well suited for marine and other
demanding environments
• High tolerance for shock and vibration
• Ultra-quiet low EMI operation
• Inrush protection
• Current limiting protection
• Reverse input protection
• High efficiency
• Output over-voltage crowbar
• Remote control option
• Wide-Temperature operation available
• Conformal coating and/or harsh environment ruggedization
available
• 3 year parts and labour warranty
Description
Applications
The BCD180 Battery Charger can be configured to run from a 24V,
32V, 48V or 72 VDC power systems to provide output voltages as
shown below.
• Marine & other rugged environments
The BCD180 Series Battery Chargers features reverse input protection, current limiting, output over-voltage protection, ultra quiet low
EMI operation and a wide operating temperature range.
• Electric Utilities and Substations
We are confident that you will get many years of reliable service from
this DC Source Battery Charger.
• Field Work / Construction Sites
• Mobile Offices (TV and Radio Vans)
• Automotive / RV
• Base Station Power(Radio & Telecommunications)
• Industrial Controls(OEM Applications)
• Solar / Alternative Power Systems
• Emergency Backup Power (UPS)
An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters
8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)
www.analyticsystems.com
DC BATTERY MODEL
CHARGER
BCD180 SERIES
Electrical (Input)
Input Volts (ip)
32
48
72
Actual (Vdc)
* 20-45
40 – 65
65 – 100
Input Amps (max)
**11.3
6.8
4.3
Input Fuse (MDA)
15
10
5
Noise on Input
< 10 mV
Electrical (Output)
Output Nominal (op)
12
24
Output Volts (DC)
13.6 ± 0.05
27.2 ± 0.05
Output Amps
15 cont.
7.5 cont.
Output Crowbar
16.0 ± 0.5V
32.0 ± 1.0V
Output Ripple & Noise
< 10 mV
Transient Response
< 1V for 50% Surge
Regulation (Line & Load)
< +/- 0.5%
Duty Cycle
Peak 20% for 10 min maximum
Continuous 100% for 24 hours per day
Efficiency
> 90% @ Maximum Output
Environment Specification
Operating Temp. Range
-20° to +40°C @ maximum output
Derate Linearly 2.5% per °C from 40°C
(Optional -40°C extra wide temp. operation avail.)
Humidity
0 - 95% Relative Humidity
(non-condensing) with optional conformal coating
Audible Noise
NONE Ødb @ 3 ft
Typical Service Life
> 10 yrs. (87,600 hrs)
Isolation
Input to Case 1500VDC (500VDC @ 32V Input)
500VDC Output to Case
Mechanical Specification
Length
7.9 in / 20.1 cm
Width
7.9 in / 20.1 cm
Height
2.4 in / 6.1 cm
Material
Marine Grade Aluminium
Finish
Black Anodize / Powder Epoxy Coat
Fastenings
All 18-8 Stainless Steel
Weight
4.0 lb / 1.8 kg
Connections
Four contact output terminals
Warranty
3 years
Safety
Designed to meet CSA 22.2.107.1 & UL458
*30 - 45 Vdc input range for a 24Vdc output
** 7.6A for 24 Vdc output
Note: Specifications are subject to change without notice.
An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters
8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)
www.analyticsystems.com