PRIOLO 15" HEIGHT 1.6 GPF FLUSHOMETER TOILET

PRIOLO 15" HEIGHT
1.6 GPF FLUSHOMETER TOILET
VITREOUS CHINA with EVERCLEAN ®
PRIOLO 15" HEIGHT 1.6 GPF with EVERCLEAN ®
• Floor mount rear outlet flushometer valve toilet
• Vitreous china
• Low-consumption (6.0 Lpf/1.6 gpf)
•EverClean® surface inhibits the growth of
stain and odor-causing bacteria, mold,
and mildew on the surface
• 15" rim height
• Condensation channel
• Elongated bowl
• Powerful direct-fed siphon jet action
• Fully glazed 2-1/8" trapway
• 1-1/2" inlet spud
• 2 bolt caps
• 100% factory flush tested
❏ 3690.016 Elongated bowl only, top spud
❏ 3690.001 Same as above, Universal Bowl
❏ 3691.016 Elongated bowl only, top spud with slotted rim for bedpan holding (White only)
❏ 3691.001 Same as above, Universal Bowl
Component Parts:
❏ 047007-0070A Inlet spud (furnished with bowl)
❏ 481310-XXX0A Bolt caps with retainers (furnished with bowl)
Nominal Dimensions:
752 x 356 x 381mm
(29-5/8" x 14" x 15")
Recommended working pressure–between
25 psi at valve when flushing and 80 psi static
Fixture only, less seat and flush valve
Compliance Certifications Meets or Exceeds the Following Specifications:
• ASME A112.19.2-2008/CSA B45.1-08 for Vitreous China Fixtures
© 2010 AS America Inc.
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
To Be Specified:
❏ Color: ❏ White ❏ Bone ❏ Linen
❏ Seat:
❏ American Standard #5901.110 Heavy duty open front less cover with EverClean ® surface
❏ American Standard #5905.110 Extra heavy duty open front less cover with EverClean ® surface
❏ Alternative Seat:
❏ Flushometer Valve:
❏ American Standard Selectronic™ #6065.161.002 DC Power (Top Spud)
❏ American Standard Selectronic™ #6065.261.007
DC Power (Back Spud)
❏ American Standard Selectronic™ #6067.261.007
AC Power (Back Spud)
❏ American Standard Selectronic™ #6068.261.007
Multi AC Power (Back Spud)
❏ Alternative Flushometer Valve:
M81
Revised 2/10
PRIOLO 15" HEIGHT
1.6 GPF FLUSHOMETER TOILET
VITREOUS CHINA with EVERCLEAN ®
3690.016/3691.016
3690.001/3691.001
1" N.P.T. OR 1" C.W.T. SUPPLY
TO FLUSH VALVE
(SUGGESTED)
FINISHED WALL
136mm
(5-3/8")
752mm
(29-5/8")
121mm
(4-3/4 " )
470mm
(18-1/2)
C/L OF SEAT POST HOLES
140mm (5-1/2 " ) CENTERS
60mm
(2-3/8")
673mm
(26-1/2 " )
356mm
(14 " )
1 -1/2"
SPUD
13mm
(1/2 " )
13mm x 25mm
slots
(1/2" x 1")
381mm
(15)
217mm
(8-1/2 " )
102mm
(4 " )
102mm
(4" )
C/L OF
WASTE
OUTLET
345mm
(13-5/8 " )
C/L OF 1/2”
DIA. HOLES
FINISHED
FLOOR
646mm
(25-3/8 " )
240mm
(9-1/2 " )
152mm
(6 " )
DIMENSIONS (Nominal) NOTE: Distance from floor to closet
flange centerline (rough-in) must be 4" (102 mm) with flange
surface flush to 1/16" (1.6mm) max. beyond finished wall.
NOTES:
PRODUCT 3690 SHOWN, 3691 SAME AS EXCEPT WITH SLOTTED RIM FOR
BED PAN HOLDING.
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM
BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST
VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING.
FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR
12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED.
REFER TO VALVE MANUFACTURER AND LOCAL CODES.
IMPORTANT: Dimensions of fixtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
© 2010 AS America Inc.
M82
Revised 2/10