You cannot Flash but only read this publication in a PDF format

Power Factor Correction
Catalogue│2013
VarSet
Low Voltage Capacitor Banks
Do you need an easy solution to
immediately boost your facility’s
energy efficiency and productivity?
Are products that blend superior quality,
performance and flexibility with
excellent value difficult to find?
Do you require the expertise,
support and reach of a global leader with
the responsiveness of a local supplier?
1 I VarSet
998-1164795_A_GMA-GB.indd 2
2012-09-24 11:42:11
Energy efficiency, as simple as VarSet
Engineered to meet your needs
Whether you run a single site operation,
or a globe-spanning enterprise, a fast and
easy way to enhance competitiveness is to
ensure that your power factor is corrected
and your electrical network delivering
optimum power.
Choosing advanced VarSet low voltage (LV)
capacitor banks is a simple and reliable
way to do that. Count on VarSet equipments
to bring true energy efficiency to your
electrical infrastructure.
High quality power = higher productivity
Power factor correction helps lower operating and capital costs and can provide
a very quick return on investment:
> Reduce capital expenses up to 30%.
Optimise electrical system capacity, avoid
oversizing and limit redundant capacity.
> Reduce reactive energy billing
penalties and lower operating
expenses up to 10%.
Boost power factor to lower utility bills
and reduce losses in transformers
and conductors.
> Reduce energy losses by up to 30%.
Optimise power consumption, reduce total
process energy consumption and reduce
CO2 emissions.
> Improve power system and
equipment reliability up to 18%.
30%
Up to
better energy
efficiency and
lower electricity
cost on your first
day with VarSet
Increase power quality to improve
business performance and reduce
unplanned outages, as well as enhance
the reliability and service life of electrical
devices, while reducing harmonics
stress and potential damage to your
electrical network.
VarSet I I
Maximizing energy efficiency just gets easier
and more economical with VarSet
without power factor correction
Power
generation
Transmission
network
Active power
Active power
Reactive power
Reactive power
Motor
with power factor correction
Power
generation
Transmission
network
Active power
Active power
Reactive power
Motor
Capacitor
Give your power infrastructure a boost
Compensating for reactive power and harmonic distortion with VarSet capacitor banks is
one of the easiest ways to quickly maintain your facility’s power factor at an ideal level for
maximum power system efficiency and cost reduction.
Superior design creates exceptional performance
Designed and manufactured by Schneider Electric, using advanced manufacturing methods
and premium materials, VarSet capacitor banks are optimised to provide superior, end-to-end
operation and value through every stage of its lifecycle.
Protection, durability and safety you can trust
With decades of power factor correction
expertise behind it, VarSet is a complete
range of high-quality, wall-mounted and
floor‑standing capacitor banks for fixed,
automatic and dynamic compensation.
Choose VarSet to make your business
more profitable, your power infrastructure
II I VarSet
more reliable and your electrical
environment more safe, VarSet
capacitor banks are suitable
for new construction or retrofit
applications in virtually any
commercial, industrial and
utility enterprise.
30%
Up to
energy loss
reduction
Comprehensive products for multiple applications
- Large choice of wall-mounted enclosures
- Extensive range of electrical steps
from 9 to 300kvar and floor-standing units
from 50 to 1150 kvar
-
Automatic compensation for variable and unstable loads up to 1150 kvar
complement to match your loads
and processes
-
uitable capacitors for any harmonic level
S
and type of loads
-
chneider Electric built-in components,
S
such as Spacial enclosures range and
innovative Linergy busbars range,
contribute in performance and safety
-
Fixed compensation for stable loads up to 200 kvar
Quality, reliability and safety
-
re-engineered power factor correction
P
solutions ensure your installation delivers
more for less on time and on budget
-
Designed for easy installation
igh quality of Schneider Electric
H
components provide high performance
and robustness
- VarSet equipment are fully type tested
- Assembly plants are ISO 9001 certified
10%
Up to
lower operating
expenses
VarSet I III
Engineered for outstanding performance
and long-term value
The entire VarSet range offers a unique
combination of abilities to give you
more convenience, reliability and costeffectiveness across a broad range
of applications. Forward-thinking
design and meticulous manufacturing
quality means you can count on VarSet
capacitor banks to deliver dependable,
long-term service
Simplicity
> Easy installation
- compact enclosure up to 300 kvar
- top or bottom cable connections
- easily accessible gland plates for
power cables
- mounting brackets for easy wall mounting
> Ease-of-use and maintenance
- automatic programming and
commissioning with Varlogic controller
- simple replacement or retrofit of
VarplusCan capacitors
> Straightforward EMS integration
- Modbus communication protocol
(Varlogic NRC12 option) for integration
with building management and energy
monitoring systems
Reliability and durability
> Long life performance
- multi-capacitor architecture
- step switching with special
design contactors
- over heating protection and alarm
for detuned reactors
- earthing studs welded to the frame
and door
IV I VarSet
Safety
> Protection
- step protection with circuit
breaker from 125 to 1150 kvar
- thermal monitoring device
- main incomer circuit breaker
protection (optional)
- direct and accidental
contact protection
- main switch rotary
handle (optional)
> Robust envelop
- IP31 protection for indoor application
- IP54 protection for dusty, industrial
environments (optional)
- IK10 protection against
mechanical shocks
- high quality welding and coating
> Tested and certified
- fully type tested according to
IEC 61439-1 & 2, IEC 61921
ISO
14000
quality certified
manufacturing
VarSet I V
Don’t trade convenience
for capability
VarSet capacitor banks are engineered to provide the features and capabilities
you need. Choose from a full range of standard, pre-configured capacitor banks
that combine high-performance with easy ordering and reliable delivery, or build a
custom VarSet solution by mixing available options to fulfil your unique requirements.
Standard VarSet LV capacitor banks
For organizations that want to get up and
running quickly, VarSet capacitor banks
are available in a range of pre-configured
apparatus you can plug right into your
network to help improve the energy
efficiency of your facility almost immediately.
Incorporating features and capabilities that
are optimised for specific applications,
standard units are available in both automatic
and fixed compensation types for high or
low harmonic environments. Choosing any
standard VarSet capacitor bank facilitates
easy ordering with short, reliable delivery
times.
Custom VarSet LV capacitor banks
For larger sites, industrials and utilities with
diverse power factor correction needs, VarSet
equipment can be ordered with a wide range
of optional capabilities and features tailored to
your specific site requirements. Customizable
VI I VarSet
VarSet capacitor banks are available in both
automatic and fixed compensation types
for high or low harmonic environments.
For your future performance
choose the leader
Quality, know-how and support you can count on
We supply quality products, integrated solutions and comprehensive services around the
world. Our proven expertise, strong local presence and reputation for quality ensure all your
projects produce exceptional value. From custom engineering, end-to-end support and valueadded tools, we’ve got you covered.
New projects
- Engineered solution, location, design,
compensation and filtering
Existing installations
- Harmonics diagnosis
- Power monitoring
- Revamping
Decommissioning
and recycling management
Maintenance
and services contracts
- Specialists close to your business
-Preventive maintenance / turn key
contracts
Training
- Preventive maintenance / operation
100%
commitment
to quality
- Dismantling
- Recovery
- Recycling
VarSet I VII
Easy selection tools matches VarSet
capabilities to your application needs
Discover how just a few short steps guide you
to your ideal VarSet solution
Our Unique selection system is user-friendly
software that quickly, easily and accurately
helps you to select the VarSet capacitor bank
configuration best able to solve your power
quality challenges. In just few easy steps you
can match available VarSet solutions to your
installation’s requirements, compare and fine
tune your choices, select the appropriate
equipment and then acquire the technical
data you need to facilitate installation and
commissioning. Use this flexible, all-in-one
tool to save time and effort so you can take
advantage of VarSet’s cost-saving abilities
as soon as possible.
“We installed 70 capacitor banks with detuned reactors
and reduced energy consumption by 10%, optimised our
electricity bill by 18% and realized payback in just 1 year.”
Madrid Barrajas airport, Spain
VIII I VarSet
Power conditioning solutions
We provide you with smart and cost-effective solutions to address power quality related issues
PB105049.eps
PB105048.eps
PB105054.eps
> VarSet LV capacitors banks
PB105053.eps
VLVAW1N
wall-mounted
VLVAW3N wall-mounted
VLVAF6P
VLVAF4P
PB107873_46.eps
PB107871_46.eps
>Harmonic active filters, AccuSine SWP and AccuSine PCS
Accusine
>Harmonic passive and hybrid filters
Varset I IX
Energy
Efficiency
Immediate
Saving
VarSet offer
Contents
A wide range of global solutions
2
Typical solutions based on applications
3
Types of compensation
4
VarSet offer
5
Small and medium buildings
400 V/50 Hz 6
Large sites
400 V/50 Hz 10
Other voltages and frequencies
12
General Characteristics
14
Physical and electrical steps
15
VarSet Components
16
Dimensions and weights
18
Ordering form Small and medium buildings
Large sites
20
24
1
A wide range of global solutions
VarSet offer
From 230 V to 690 V, 50 and 60 Hz
Automatic compensation
Fixed compensation
Power VLVAW0N VLVAW1N VLVAW2N VLVAF4P VLVAW3N VLVAF5N VLVAF6P VLVAF7N VLVAF8P VLVFW0N VLVFW1N VLVFW2N VLVFF4P
(kvar)
350
600
700
1150
225
600
9
32
50
100
125
200
700
1150
50
200
350
600
9
32
50
100
16
32
50
100
125
200
300
600
175
200
125
200
350
600
150
200
100
200
250
600
350
600
250
600
PB105049.eps
PB105054.eps
PB105048.eps
Rated Voltage 400 V/50 Hz - 415 V/50 Hz - 480 V/60 Hz
Low
min 6
34
125
175
polluted max 32
100
300
150
network
Polluted min
50
network max
200
Rated Voltage 400 V/60 Hz
Low
min 9
34
125
225
polluted max 32
100
300
200
network
Polluted min
100
network max
200
Rated Voltage 230 V/50 Hz
Low
min 9
34
polluted max 32
100
network
Rated Voltage 240 V/60 Hz
Low
min 9
34
125
polluted max 32
100
150
network
Polluted min
50
network max
100
Rated Voltage 600 V/60 Hz
Low
min
125
250
polluted max
200
300
network
Polluted min
75
network max
200
Rated Voltage 690 V/50 Hz
Low
min
125
polluted max
200
network
Polluted min
network max
PB105053.eps
PB105046.eps
VarSet
LV type
VLVAF6P
VLVAF4P
VLVAW3N
VLVAW1N
> Consistent range of wall-mounted and floor-standing capacitor banks.
> Large choice of electrical steps according to your loads and process.
> Automatic or fixed compensation.
> Adapted to networks with low to high harmonic distorsion.
> One range for World-Wide needs: p from 230 V to 690 V
2
p 50 and 60 Hz.
VLVAW0N
VarSet offer
Customer requirements
The table below shows the solutions most
frequently used in different types of
applications.
In all cases, it is strongly recommended
that measurements be carried out on site
in order to validate the solution.
Typical solutions based
on applications
Industry
Heavy Duty
Capacitors
Heavy Duty Capacitors
and Detuned Reactors
Food and beverage
Textiles
Wood
Paper
Printing
Chemicals - pharmaceuticals
Plastics
Glass - ceramics
Steel production
Metallurgy
Automotive
Cement works
Mining
Refineries
Microelectronics
Tertiary
Banks - insurances
Supermarkets
Hospitals
Stadiums
Amusement parks
Hotels - offices
Energy and infrastructure
Substations
Water distribution
Internet
Railway transport
Airports
Underground train systems
Bridges
Tunnels
Wind turbines
Very frequently
Usually
3
Types of compensation
VarSet offer
The compensation needs of your installation vary depending on factors such as load
variation, network pollution level and the characteristics of the installation. Find out the right
level of compensation for your network with the help of the chart below.
Variable or unstable load
Stable load
Your load variation
Choose
automatic compensation
Choose
fixed compensation
Network pollution level
Network pollution level
Low polluted
Gh/Sn < 20 %
Choose heavy
duty capacitors
Polluted
20 % < Gh/Sn < 50 %
Choose heavy
duty capacitors +
detuned reactors
Compensation type
b Automatic compensation:
This compensation type is used for unstable loads.
The VarSet LV equipment will automatically adjust
the reactive power according to variations in load
and/or power factor.
Schneider Electric recommends the use of automatic
compensation when the capacitor bank's power is more
than 15 % of the power of the transformer,
in order to avoid overcompensation.
b Fixed compensation:
This compensation type is used for stable loads,
with synchronised voltage and current.
The equipment will supply a constant reactive
power irrespective of load variations.
Low polluted
Gh/Sn < 20 %
Choose heavy
duty capacitors
Choose heavy
duty capacitors +
detuned reactors
Network pollution
Non-linear loads, such as devices using power electronics,
generate harmonic pollution on the network.
The selection of the appropriate power factor correction
solution has to be adapted depending on the level of
network pollution.
The selection is based on the value of the Gh/Sn ratio, with:
Gh = total power of the non–linear loads
Sn = rated power of the supply transformer
The selection can also be made according to the
percentage of total harmonic current distorsion THDi or
total harmonic voltage distorsion THDu measured.
> For rapidly fluctuating loads (dynamic compensation), please contact us.
4
Polluted
20 % < Gh/Sn < 50 %
VarSet offer
VarSet offer
The new VarSet range of power factor correction equipments by Schneider Electric,
offers the best-in-class performance with a range of features and options that satisfy the
requirements of the most demanding customers.
Our solutions are truly unique in terms of robustness and the high quality of our equipments.
Furthermore, the offer has been simplified to facilitate easy ordering and provide short and
reliable delivery times.
VarSet
Small and medium buildings
Building
Large sites
Building
Industry
Characteristics:
< 10000 m2
y 1000 kVA
Characteristics:
> 10000 m2
> 1000 kVA
Key benefits of our offer:
p Quick return on investments
p Easy to select
p Short delivery times
Key benefits of our offer:
p Easy to install and commission
p Easy to adapt
p Reliable delivery time
> Please contact us for other power needs, dynamic compensation and special requirements.
5
Small and medium buildings
VarSet offer
400 V/50 Hz
Automatic compensation
Low polluted network
F All references are equipped with auxiliary transformer.
Our list of references for the small and
medium buildings market are pre-defined
solutions, incorporating the features that
are best suited to the customer needs.
These solutions are simple to select,
optimally designed with a short delivery
window, resulting in immediate energy
savings.
Low
polluted
Network
Reference number
Wall-mounted
VLVAW0N03526AA
VLVAW0N03501AA
VLVAW0N03527AA
VLVAW0N03502AA
VLVAW0N03503AA
VLVAW0N03504AA
VLVAW1N03505AA
VLVAW1N03528AA
VLVAW1N03506AA
VLVAW1N03529AA
VLVAW1N03507AA
VLVAW1N03530AA
VLVAW1N03508AA
VLVAW2N03509AA
VLVAW2N03531AA
With
VLVAW2N03510AA
incomer
VLVAW3N03511AA
protection
VLVAW3N03512AA
circuit
VLVAW3N03513AA
breaker
VLVAW3N03532AA
VLVAW3N03514AA
VLVAW3N03515AA
VLVAW3N03516AA
Floor-standing
VLVAF5N03517AA
VLVAF5N03518AA
VLVAF5N03533AA
VLVAF5N03519AA
VLVAF5N03520AA
VLVAF5N03521AA
VLVAF5N03522AA
VLVAF7N03534AA
VLVAF7N03536AA
VLVAF7N03537AA
VLVAF7N03539AA
6
Power
(kvar)
IP 31
IPxxB 15kA
35kA
Top
Bottom
Rotary
(door circuit circuit connection connection handle
open) breaker breaker
Varlogic
NR6/12
6
9
12.5
16
22
32
34
37.5
50
69
75
87.5
100
125
137.5
150
175
200
225
238
250
275
300
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
350
400
425
450
500
550
600
700
900
1000
1150
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
Small and medium buildings
VarSet offer
400 V/50 Hz
Automatic compensation
Low polluted network
F All references are equipped with auxiliary transformer.
Our list of references for the small and
medium buildings market are pre-defined
solutions, incorporating the features that
are best suited to the customer needs.
These solutions are simple to select,
optimally designed with a short delivery
window, resulting in immediate energy
savings.
Low
polluted
Network
Reference number
Wall-mounted
VLVAW2N03509AB
VLVAW2N03531AB
VLVAW2N03510AB
VLVAW3N03511AB
VLVAW3N03512AB
VLVAW3N03513AB
VLVAW3N03532AB
VLVAW3N03514AB
VLVAW3N03515AB
Without
VLVAW3N03516AB
incomer
protection Floor-standing
circuit
VLVAF5N03517AB
breaker
VLVAF5N03518AB
VLVAF5N03533AB
VLVAF5N03519AB
VLVAF5N03520AB
VLVAF5N03521AB
VLVAF5N03522AB
VLVAF7N03534AB
VLVAF7N03536AB
VLVAF7N03537AB
VLVAF7N03539AB
Power
(kvar)
IP31
IPxxB
(door
open)
Short-time
withstand
current
Top
connection
Bottom
connection
Varlogic
NR6/12
125
137.5
150
175
200
225
238
250
275
300
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
350
400
425
450
500
550
600
700
900
1000
1150
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
7
Small and medium buildings
VarSet offer
400 V/50 Hz
Automatic compensation
Polluted network
F All references are equipped with auxiliary transformer.
Our list of references for the small and
medium buildings market are pre-defined
solutions, incorporating the features that are
best suited to the customer needs. These
solutions are simple to select, optimally
designed with a short delivery window,
resulting in immediate energy savings.
Polluted
Network
Reference number
Floor-standing
VLVAF4P03506AA
VLVAF4P03507AA
VLVAF4P03530AD
VLVAF4P03508AA
VLVAF4P03508AD
VLVAF4P03509AA
VLVAF4P03509AD
VLVAF4P03531AA
VLVAF4P03510AA
VLVAF4P03510AD
VLVAF4P03511AA
VLVAF4P03511AD
VLVAF4P03512AA
VLVAF4P03512AD
VLVAF6P03513AA
VLVAF6P03513AD
VLVAF6P03514AA
With
VLVAF6P03514AD
incomer
VLVAF6P03515AA
protection
VLVAF6P03515AD
circuit
VLVAF6P03516AA
breaker
VLVAF6P03516AD
VLVAF6P03517AA
VLVAF6P03517AD
VLVAF6P03518AA
VLVAF6P03518AD
VLVAF6P03519AA
VLVAF6P03519AD
VLVAF6P03520AA
VLVAF6P03520AD
VLVAF6P03521AA
VLVAF6P03522AA
VLVAF6P03522AD
VLVAF8P03534AA
VLVAF8P03535AA
VLVAF8P03536AA
VLVAF8P03537AA
VLVAF8P03538AA
VLVAF8P03539AA
8
Power
(kvar)
50
75
87.5
100
100
125
125
137.5
150
150
175
175
200
200
225
225
250
250
275
275
300
300
350
350
400
400
450
450
500
500
550
600
600
700
800
900
1000
1100
1150
Tuning Tuning IP31
factor factor
3.8
4.2
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
IPxxB 35kA
Top
Bottom
Rotary Varlogic
(door circuit connection connection handle NR6/12
open) breaker
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
Small and medium buildings
VarSet offer
400 V/50 Hz
Automatic compensation
Polluted network
F All references are equipped with auxiliary transformer.
Our list of references for the small and
medium buildings market are pre-defined
solutions, incorporating the features that are
best suited to the customer needs. These
solutions are simple to select, optimally
designed with a short delivery window,
resulting in immediate energy savings.
Polluted
Network
Reference number
Floor-standing
VLVAF4P03506AB
VLVAF4P03507AB
VLVAF4P03530AE
VLVAF4P03508AB
VLVAF4P03508AC
VLVAF4P03508AE
VLVAF4P03509AB
VLVAF4P03509AE
VLVAF4P03531AB
VLVAF4P03510AB
VLVAF4P03510AE
VLVAF4P03511AB
VLVAF4P03511AE
VLVAF4P03512AB
VLVAF4P03512AC
VLVAF4P03512AE
VLVAF6P03513AB
VLVAF6P03513AE
VLVAF6P03514AB
Without
VLVAF6P03514AE
incomer
protection VLVAF6P03515AB
circuit
VLVAF6P03515AE
breaker
VLVAF6P03516AB
VLVAF6P03516AC
VLVAF6P03516AE
VLVAF6P03517AB
VLVAF6P03517AE
VLVAF6P03518AB
VLVAF6P03518AE
VLVAF6P03519AB
VLVAF6P03519AE
VLVAF6P03520AB
VLVAF6P03520AE
VLVAF6P03521AB
VLVAF6P03522AB
VLVAF6P03522AE
VLVAF8P03534AB
VLVAF8P03535AB
VLVAF8P03536AB
VLVAF8P03537AB
VLVAF8P03538AB
VLVAF8P03539AB
Power
(kvar)
50
75
87.5
100
100
100
125
125
137.5
150
150
175
175
200
200
200
225
225
250
250
275
275
300
300
300
350
350
400
400
450
450
500
500
550
600
600
700
800
900
1000
1100
1150
Tuning Tuning IP31
factor factor
3.8
4.2
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
IPxxB
(door
open)
Short-time
withstand
current
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
Top
Bottom
Varlogic
connection connection NR6/12
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
9
Large sites
VarSet offer
400 V/50 Hz
Automatic compensation
For the large sites and large buildings,
a wide range of available kvar with
attractive options that can be chosen
at the discretion of the customer.
This is to facilitate adaptation to specific
requirements.
Network
pollution
VLVAW2N
VLVAW3N
Wall-mounted or floor-standing
Network
pollution
Power (kvar)
125
175
137.5
200
150
225
Low polluted
275
300
Tuning Factor 3.8
Tuning Factor 4.2
50
50
50
75
75
75
87.5
87.5
87.5
100
100
100
125
125
125
137.5
137.5
137.5
150
150
150
175
175
175
200
200
200
Power (kvar)
238
250
VLVAF4P
Floor-standing
Tuning Factor 2.7
Polluted
Available options
b IP protection for the enclosure
v IP31
v IP54, harsh and dusty environments
b Protection against direct contact with door open
v IPxxB protection
v No IPxxB protection
b Incomer protection
v 35 kA circuit breaker protection, with rotary handle
v 35 kA circuit breaker protection, without rotary handle
v 65 kA circuit breaker protection, with rotary handle
v 65 kA circuit breaker protection, without rotary handle
v No incomer protection
b Cable connection
v Top connection
v Bottom connection
Use our online
configurator tool for
easy selection and
order processing.
Log on your local
Schneider Electric
web site.
10
b Auxiliary transformer
b Varlogic power factor controller
v NR6/12 controllers
v NRC12 controller with Modbus communication
VarSet offer
Large sites
400 V/50 Hz
Automatic compensation
F Auxiliary transformer always integrated as a standard
For the large sites and large buildings,
a wide range of available kvar with
attractive options that can be chosen
at the discretion of the customer.
This is to facilitate adaptation to specific
requirements.
Network
pollution
VLVAF5N
Floor-standing
Network
pollution
Power (kvar)
350
225
425
450
500
550
600
Tuning
Factor 3.8
Tuning
Factor 4.2
225
225
Power (kvar)
400
Low polluted
VLVAF6P
Floor-standing
Tuning
Factor 2.7
Polluted
250
250
250
275
275
275
300
300
300
350
350
350
400
400
400
450
450
450
500
500
500
550
550
550
600
600
600
Available options
b IP protection for the enclosure
v IP31
v IP54, harsh and dusty environments
b Protection against direct contact with door open
v IPxxB protection
v No IPxxB protection
b Incomer protection
v 35 kA circuit breaker protection, with rotary handle
v 35 kA circuit breaker protection, without rotary handle
v 65 kA circuit breaker protection, with rotary handle
v 65 kA circuit breaker protection, without rotary handle
v No incomer protection
Use our online
configurator tool for
easy selection and
order processing.
Log on your local
Schneider Electric
web site.
b Cable connection
v Top connection
v Bottom connection
b Varlogic power factor controller
v NR6/12 controllers
v NRC12 controller with Modbus communication
11
VarSet offer
Other voltages and frequencies
230 V/50 Hz- 690 V/50 Hz
Automatic or fixed compensation
A wide range of available kvar with
attractive options can be chosen to meet
your requirements.
Adapted to networks with low to high
harmonic distorsion.
230V/50Hz
Low
VLVAW0N
polluted Wall-mounted
VLVAW1N
Power (kvar)
Min.
9
34
Max.
32
100
690V/50Hz
Low
VLVAW2N
polluted Wall-mounted or floor-standing
VLVAW5N
Floor-standing
Polluted VLVAF6P
Floor-standing
Power (kvar)
Power (kvar)
Min.
125
350
Min.
250
Max.
200
600
Max.
600
Available options
b IP protection for the enclosure
v IP31
v IP54, harsh and dusty environments
b Protection against direct contact with door open
v IPxxB protection
v No IPxxB protection
b Incomer protection
v 35 kA circuit breaker protection, with rotary handle
v 35 kA circuit breaker protection, without rotary handle
v 65 kA circuit breaker protection, with rotary handle
v 65 kA circuit breaker protection, without rotary handle
v No incomer protection
b Cable connection
v Top connection
v Bottom connection
b Auxiliary transformer
v Included in VLVAF5N and VLVAF6P
Use our online
configurator tool for
easy selection and
order processing.
Log on your local
Schneider Electric
web site.
b Varlogic power factor controller
v NR6/12 controllers
v NRC12 controller with Modbus communication
> For the details of physical steps, please contact us.
12
Other voltages and frequencies
VarSet offer
240 V/60 Hz - 400 V/60 Hz - 600 V/60 Hz
Automatic or fixed compensation
A wide range of available kvar with
attractive options can be chosen to meet
your requirements.
Adapted to networks with low to high
harmonic distorsion.
240V/60Hz
Low
VLVAW0N
polluted Wall-mounted
VLVAW1N
VLVAW2N
Wall-mounted or floor-standing
Polluted VLVAF4P
Floor-standing
Power (kvar)
Power (kvar)
Min.
9
34
150
Min.
50
Max.
32
100
200
Max.
200
400V/60Hz
Low
VLVAW0N
VLVAW1N
polluted Wall-mounted
VLVAW2N
VLVAW3N
VLVAF5N
Wall-mounted or floor-standing Floor-standing
Polluted VLVAF4P VLVAF6P
Floor-standing
Power (kvar)
Power (kvar)
Min.
9
34
125
225
350
Min.
100
300
Max.
32
100
200
300
600
Max.
200
600
600V/60Hz
Low
VLVAW2N
VLVAW3N
polluted Wall-mounted or floor-standing
VLVAF5N
Floor-standing
Polluted VLVAF4P VLVAF6P
Floor-standing
Power (kvar)
Power (kvar)
Min.
125
250
350
Min.
75
300
Max.
200
250
600
Max.
200
600
Available options
b IP protection for the enclosure
v IP31
v IP54, harsh and dusty environments
b Protection against direct contact with door open
v IPxxB protection
v No IPxxB protection
b Incomer protection
v 35 kA circuit breaker protection, with rotary handle
v 35 kA circuit breaker protection, without rotary handle
v 65 kA circuit breaker protection, with rotary handle
v 65 kA circuit breaker protection, without rotary handle
v No incomer protection
b Cable connection
v Top connection
v Bottom connection
Use our online
configurator tool for
easy selection and
order processing.
Log on your local
Schneider Electric
web site.
b Auxiliary transformer
v Included in VLVAF5N and VLVAF6P
b Varlogic power factor controller
v NR6/12 controllers
v NRC12 controller with Modbus communication
> For the details of physical steps, please contact us.
13
VarSet offer
General Characteristics
Varset
Environment
Installation
Indoor
Ambient temperature
-5 °C to 40 °C
Average temperature
+35 °C
+45 °C with derating
Humidity
up to 95 %
Maximum altitude
2000 m
Enclosure
Degree of protection
IP31
IP54 (option)
Colour
RAL 9003
Degree of mechanical
resistance
IK10
Protection against direct
contacts with door open
IPxxB (Option)
Steps
Step protection
With circuit breaker
from 125 kvar for low polluted network and
from 50 kvar for polluted network
Electrical characteristics
Connection type
Three-phase
Power losses
< 2.5 W/kvar without detuned reactors
< 6 W/kvar with detuned reactors
Short-time withstand
current
35 kA or 65 kA with circuit breaker
30 kA, 1 s or 35 kA, 1 s without circuit breaker
Maximum permissible
1.3 In without detuned reactor
over current (with thermal
1.31 In with 4.2 tuning factor
protection included)
1.19 In with 3.8 tuning factor
1.12 In with 2.7 tuning factor
Maximum permissible
over voltage
1.1 x Un, 8 h every 24 h
Standards
IEC 61921
IEC 61439-1/2
Environment certifications
RoHS compliant, produced in 14001 certified plants,
product environmental profile available
14
Physical and electrical steps
VarSet offer
400 V/50 Hz
Equipment
type
Low polluted
VLVAW0N
VLVAW1N
VLVAW2N
VLVAW3N
VLVAF5N
Polluted
VLVAF4P
VLVAF6P
Min step
Power
Regulation
Number of
physical steps
Number of
electrical steps
Sequence
3
3
3
3
3
6.25
3
6.25
6.25
6.25
25
12.5
25
25
12.5
50
12.5
25
25
12.5
25
25
50
50
50
25
50
50
50
50
6
9
12.5
16
22
32
34
37.5
50
69
75
87.5
100
125
137.5
150
175
200
225
238
250
275
300
350
400
425
450
500
550
600
2x3
3 + 6.25
3 + 3 + 6.25
3 + 2x6.25
3 + 6.25 + 12.5
6.25 + 2x12.5
3 + 6.25 + 2x12.5
2x6.25 + 2x12.5
6.25+6.25+12.5+25
6.25+12.5+2x25
3x25
12.5+3x25
4x25
25 + 2x50
12.5+25+2x50
3x50
2x12.5+2x25+2x50
25+25+3x50
25 + 4x50
12.5+25+4x50
2x25 + 4x50
25 + 5x50
6x50
50 + 3x100
2x50 + 3x100
25+2x50+3x100
50 + 4x100
2x50 + 4x100
50 + 5x100
2x50 + 5x100
2
2
3
3
3
3
4
4
4
4
3
4
4
3
4
3
6
5
5
6
6
6
6
4
5
6
5
6
6
7
2
3
4
5
7
5
11
6
8
11
3
7
4
5
11
3
14
8
9
19
10
11
6
7
8
17
9
10
11
12
1.1
1.2
1.1.2
1.2.2
1.2.4
1.2.2
1.2.4
1.1.2
1.1.2.4
1.2.4
1.1.1
1.2.2
1.1.1
1.2.2
1.2.4
1.1.1
1.1.2.2.4
1.1.2
1.2.2
1.2.4
1.1.2
1.2.2
1.1.1
1.2.2
1.1.2
1.2.2.4
1.2.2
1.1.2
1.2.2
1.1.2
12.5
12.5
12.5
12.5
25
12.5
25
25
50
25
50
25
50
50
50
50
50
50
100
50
75
87.5
100
125
137.5
150
175
200
225
250
275
300
350
400
450
500
550
600
4x12.5
2x12.5 + 2x25
12.5 + 3x25
2x12.5 + 25 + 50
25 + 2x50
12.5+25+2x50
2x25 + 2x50
25 + 3x50
4x50
25+2x50+100
50 + 2x100
25+50+2x100
2x50 + 2x100
50 + 3x100
2x50 + 3x100
50 + 4x100
2x50 + 4x100
50+5x100
6x100
4
4
4
4
3
4
4
4
4
4
3
4
4
4
5
5
6
6
6
4
6
7
8
5
11
6
7
4
9
5
11
6
7
8
9
10
11
6
1.1.1
1.1.2
1.2.2
1.1.2.4
1.2.2
1.2.4
1.1.2
1.2.2
1.1.1
1.2.2.4
1.2.2
1.2.4
1.1.2
1.2.2
1.1.2
1.2.2
1.1.2
1.2.2
1.1.1
> For VLVAF7N and VLVAF8P, please consult us.
15
VarSet offer
VarSet Components
Our VarSet offer comes with the assurance that the components
inside are manufactured by Schneider Electric, thus assuring high
quality.
PE90131.eps
VarplusCan: Heavy duty capacitors
VarSet range of equipments are integrated with heavy duty aluminum can
capacitors (Varplus Can) that are especially designed and engineered to
deliver a long life expectancy with low losses.
Features:
p high life expectancy
p high overload capabilities with good thermal and mechanical properties
VarplusCan capacitors
p self-healing with discharge resistors
p pressure-sensitive disconnector on all three phases
p special film resistivity and metallization profile for higher thermal efficiency
and enhanced life expectancy.
PE90158.eps
LC1-D electromagnetic contactors
Capacitor control is accompanied by a transient state resulting from the
capacitor load. This generates a very high overcurrent, equivalent to a short
circuit of short duration.
Unique technology contactors
The contactors used in our devices are specifically designed for capacitor
control. They are fitted with a contact block allowing the current to pass on
closing and with damping resistors that limit the current on energisation.
TeSys LC1D range of contactors
Personal safety
The contactors cannot be operated manually. The contactors are fitted with
covers to protect them from direct contact.
Safety of installations.
Damping resistors are used to reduce transient voltage surges.
PE90154.eps
Long service life
These contactors are a ready-to-use solution that avoids the installation of
shock coils. Their service life is far longer than that of conventional solutions.
Detuned reactors
Detuned reactors
Detuned Reactors enable the protection of capacitors against harmonic
pollution. They are recommended for usage in polluted networks, with choice
of three tuning factors: 2.7, 3.8 and 4.2.
They are equipped with thermal protection device for step disconnection.
Spacial enclosures
PB105054.eps
p IP31: recommended for indoor usage. Protection against condensation as
well as tools and wires (>2.5 mm).
p IP54: recommended for harsh and dusty environments (indoor usage).
Protection against ingress of dust and condensation.
p IK10: maximum possible protection against mechanical shocks and can
withstand energy of 20 joules.
These degrees of protection are defined by standards IEC 60529 (IP) and
IEC 62262 (IK).
Spacial enclosures
16
LVAC1_v1_22-06-12.eps
VarSet offer
VarSet Components
IP door open protects against direct physical contact with voltage for more
safety of operating personnel.
IPxxB: ensures protection against live parts that retain voltage even when
door is open (protection against access with finger).
Step circuit breaker
Cabinet with door open
From 125 kvar for low polluted network and from 50 kvar for polluted
network, each physical step is protected by a step circuit breaker that
ensures that our equipments are highly fault-tolerant, ensuring continuity
of service even when one or more capacitors are malfunctioning.
The details of the steps are on page 15.
PB110406_40.eps
Incomer circuit breaker
Circuit breakers
Schneider Electric’s range of circuit breakers is designed to ensure maximum
continuity of service. Our VarSet range of products have the option of being
protected with a main incomer circuit breaker; no spare fuses required and
overload protection that cannot be achieved with HRC fuses.
While the smaller power ranges (less than 100 kvar), are always protected
with circuit breakers of up to 35 kA breaking capacity, our larger power
ranges (over 100 kvar) come with an option to integrate circuit breakers of
either 35 kA breaking capacity or 65 kA for industrial networks.
Rotary handle is also provided as an option to facilitate the disconnection
of circuit breakers, before opening the door. This is an additional protection
mechanism to ensure the safety of personnel.
PE90161.eps
Varlogic N Power Factor Controller
Varlogic NR6
Our range of Varlogic N series of Power Factor Controllers are simple to
program, reliable and intelligent. Varlogic Controllers offer user friendly
features such as a large backlit display, intuitive menus, ergonomic layout of
buttons, direct display of main measurements and intelligent self set-up.
The Varlogic N controllers constantly measure the reactive power of the
installation and control the connection and disconnection of capacitor steps,
to obtain the required power factor. The range is composed of:
p NR6: control up to 6 capacitor steps
PB105066.eps
p NR12: control up to 12 capacitor steps
p NRC12 with Modbus: control up to 12 capacitor steps, with advanced
diagnostic functions and integrated Modbus interface communication
module, which enables Varlogic functions to be connected to the energy
management controller iRIO. This is the hub on the On site Energy
Management Solution designed by Schneider Electric to ensure energy
savings for a long time.
Varlogic NRC12
Auxiliary Transformer
Auxiliary units such as contactors, controllers, and fans, operate only on
230 Volts. For installation other than 230 Volts, the voltage for the auxiliaries
has to be converted by an auxiliary transformer. In order to simplify the
installation process, VarSet equipments can be integrated with an auxiliary
transformer (chosen as an option).
Other Accessories
Accessories such as plinth (for easier installation on uneven surfaces) can be
ordered as an option along with the VarSet equipments.
17
Dimensions and weights
VarSet offer
W
1
1
DB413484.eps
DB413483-EN.eps
DB413482-EN.eps
VLVAW0N, VLVFW0N, VLVAW1N and VLVFW1N wall-mounted
1
2
61
H
2
D
61
12
2
D1
1
W
H
H
2
DB413486-EN.eps
W
DB413485-EN.eps
DB413954-EN.eps
VLVAW2N, VLVFW2N and VLVAW3N
D
D
D1
W
DB413488-EN.eps
DB413487-EN.eps
VLVAF4P and VLVFF4P floor-standing
H
D
18
D1
Dimensions and weights
VarSet offer
DB413490-EN.eps
DB413489-EN.eps
VLVAF5N floor-standing
W
H
D
D1
DB413492-EN.eps
DB413491-EN.eps
VLVAF6P floor-standing
W
H
D
D1
Dimensions (mm) and maximum weight (kg)
Wall-mounted
VLVAW0N
H
650
W
450
D
250
D1
686
Weight 57
VLVFW0N
650
450
250
686
48
Floor-standing
VLVAW1N
700
600
300
886
73
VLVFW1N
700
600
300
886
64
VLVAW2N
1200 (1)
800
300
1086
131
VLVFW2N
1200 (1)
800
300
1086
117
VLVAW3N
1200 (1)
1000
300
1286
175
VLVAF4P
1300
1600
300
1086
334
VLVFF4P
1300
1600
300
1086
319
VLVAF5N
2200
800
600
1361
434
VLVAF6P
2200
1400
600
1361
952
(1) With plinth: +100 mm.
> For VLVAF7N and VLVAF8P, please consult us.
19
Ordering form
VarSet offer
Small and medium buildings
400 V/50 Hz
Automatic compensation
Low polluted network
Customer name: ..............................................................................................................................................................................................................................
Delivery address: ..............................................................................................................................................................................................................................
Requested delivery date: ...........................................................................................................................................................................................
Customer order no.: ...............................................................................................................................................................................................................
F All references are equipped with auxiliary transformer.
Low
polluted
Network
Reference number
Wall-mounted
v VLVAW0N03526AA
v VLVAW0N03501AA
v VLVAW0N03527AA
v VLVAW0N03502AA
v VLVAW0N03503AA
v VLVAW0N03504AA
v VLVAW1N03505AA
v VLVAW1N03528AA
v VLVAW1N03506AA
v VLVAW1N03529AA
v VLVAW1N03507AA
v VLVAW1N03530AA
v VLVAW1N03508AA
v VLVAW2N03509AA
v VLVAW2N03531AA
With
v VLVAW2N03510AA
incomer
v VLVAW3N03511AA
protection
v VLVAW3N03512AA
circuit
v VLVAW3N03513AA
breaker
v VLVAW3N03532AA
v VLVAW3N03514AA
v VLVAW3N03515AA
v VLVAW3N03516AA
Floor-standing
v VLVAF5N03517AA
v VLVAF5N03518AA
v VLVAF5N03533AA
v VLVAF5N03519AA
v VLVAF5N03520AA
v VLVAF5N03521AA
v VLVAF5N03522AA
v VLVAF7N03534AA
v VLVAF7N03536AA
v VLVAF7N03537AA
v VLVAF7N03539AA
20
Power
(kvar)
IP 31
IPxxB 15kA
35kA
Top
Bottom
Rotary
(door circuit circuit connection connection handle
open) breaker breaker
6
9
12.5
16
22
32
34
37.5
50
69
75
87.5
100
125
137.5
150
175
200
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
225
238
250
275
300
b
b
b
b
b
350
400
425
450
500
550
600
700
900
1000
1150
b
b
b
b
b
b
b
b
b
b
b
Varlogic
NR6/12
-
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
Ordering form
VarSet offer
Small and medium buildings
400 V/50 Hz
Automatic compensation
Low polluted network
Customer name: ..............................................................................................................................................................................................................................
Delivery address: ..............................................................................................................................................................................................................................
Requested delivery date: ...........................................................................................................................................................................................
Customer order no.: ...............................................................................................................................................................................................................
F All references are equipped with auxiliary transformer.
Low
polluted
Network
Reference number
Power
(kvar)
IP31
IPxxB
(door
open)
Short-time
withstand
current
Top
connection
Bottom
connection
Varlogic
NR6/12
Wall-mounted
v VLVAW2N03509AB
v VLVAW2N03531AB
v VLVAW2N03510AB
v VLVAW3N03511AB
v VLVAW3N03512AB
v VLVAW3N03513AB
v VLVAW3N03532AB
v VLVAW3N03514AB
v
VLVAW3N03515AB
Without
v
VLVAW3N03516AB
incomer
protection Floor-standing
circuit
v VLVAF5N03517AB
breaker
v VLVAF5N03518AB
v VLVAF5N03533AB
v VLVAF5N03519AB
v VLVAF5N03520AB
v VLVAF5N03521AB
v VLVAF5N03522AB
v VLVAF7N03534AB
v VLVAF7N03536AB
v VLVAF7N03537AB
v VLVAF7N03539AB
125
137.5
150
175
200
225
238
250
275
300
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
350
400
425
450
500
550
600
700
900
1000
1150
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
21
Ordering form
VarSet offer
Small and medium buildings
400 V/50 Hz
Automatic compensation
Polluted network
Customer name: ..............................................................................................................................................................................................................................
Delivery address: ..............................................................................................................................................................................................................................
Requested delivery date: ...........................................................................................................................................................................................
Customer order no.: ...............................................................................................................................................................................................................
F All references are equipped with auxiliary transformer.
Polluted
Network
Reference number
Floor-standing
v VLVAF4P03506AA
v VLVAF4P03507AA
v VLVAF4P03530AD
v VLVAF4P03508AA
v VLVAF4P03508AD
v VLVAF4P03509AA
v VLVAF4P03509AD
v VLVAF4P03531AA
v VLVAF4P03510AA
v VLVAF4P03510AD
v VLVAF4P03511AA
v VLVAF4P03511AD
v VLVAF4P03512AA
v VLVAF4P03512AD
v VLVAF6P03513AA
v VLVAF6P03513AD
v VLVAF6P03514AA
With
v VLVAF6P03514AD
incomer
v VLVAF6P03515AA
protection
v VLVAF6P03515AD
circuit
v VLVAF6P03516AA
breaker
v VLVAF6P03516AD
v VLVAF6P03517AA
v VLVAF6P03517AD
v VLVAF6P03518AA
v VLVAF6P03518AD
v VLVAF6P03519AA
v VLVAF6P03519AD
v VLVAF6P03520AA
v VLVAF6P03520AD
v VLVAF6P03521AA
v VLVAF6P03522AA
v VLVAF6P03522AD
v VLVAF8P03534AA
v VLVAF8P03535AA
v VLVAF8P03536AA
v VLVAF8P03537AA
v VLVAF8P03538AA
v VLVAF8P03539AA
22
Power
(kvar)
50
75
87.5
100
100
125
125
137.5
150
150
175
175
200
200
225
225
250
250
275
275
300
300
350
350
400
400
450
450
500
500
550
600
600
700
800
900
1000
1100
1150
Tuning Tuning IP31
factor factor
3.8
4.2
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
IPxxB 35kA
Top
Bottom
Rotary Varlogic
(door circuit connection connection handle NR6/12
open) breaker
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
Ordering form
VarSet offer
Small and medium buildings
400 V/50 Hz
Automatic compensation
Polluted network
Customer name: ..............................................................................................................................................................................................................................
Delivery address: ..............................................................................................................................................................................................................................
Requested delivery date: ...........................................................................................................................................................................................
Customer order no.: ...............................................................................................................................................................................................................
F All references are equipped with auxiliary transformer.
Polluted
Network
Reference number
Power
(kvar)
Tuning Tuning IP31
factor factor
3.8
4.2
IPxxB
(door
open)
Short-time
withstand
current
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
30 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
35 kA, 1 s
Top
Bottom
Varlogic
connection connection NR6/12
Floor-standing
v VLVAF4P03506AB
v VLVAF4P03507AB
v VLVAF4P03530AE
v VLVAF4P03508AB
v VLVAF4P03508AC
v VLVAF4P03508AE
v VLVAF4P03509AB
v VLVAF4P03509AE
v VLVAF4P03531AB
v VLVAF4P03510AB
v VLVAF4P03510AE
v VLVAF4P03511AB
v VLVAF4P03511AE
v VLVAF4P03512AB
v VLVAF4P03512AC
v VLVAF4P03512AE
v VLVAF6P03513AB
v VLVAF6P03513AE
v VLVAF6P03514AB
Without
v VLVAF6P03514AE
incomer
protection v VLVAF6P03515AB
circuit
v VLVAF6P03515AE
breaker
v VLVAF6P03516AB
v VLVAF6P03516AC
v VLVAF6P03516AE
v VLVAF6P03517AB
v VLVAF6P03517AE
v VLVAF6P03518AB
v VLVAF6P03518AE
v VLVAF6P03519AB
v VLVAF6P03519AE
v VLVAF6P03520AB
v VLVAF6P03520AE
v VLVAF6P03521AB
v VLVAF6P03522AB
v VLVAF6P03522AE
v VLVAF8P03534AB
v VLVAF8P03535AB
v VLVAF8P03536AB
v VLVAF8P03537AB
v VLVAF8P03538AB
v VLVAF8P03539AB
50
75
87.5
100
100
100
125
125
137.5
150
150
175
175
200
200
200
225
225
250
250
275
275
300
300
300
350
350
400
400
450
450
500
500
550
600
600
700
800
900
1000
1100
1150
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
-
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
23
Ordering form
VarSet offer
Large sites
400 V/50 Hz
Automatic compensation
Customer name: ..............................................................................................................................................................................................................................
Delivery address: ..............................................................................................................................................................................................................................
Requested delivery date: ...........................................................................................................................................................................................
Customer order no.: ...............................................................................................................................................................................................................
Network
pollution
VLVAW2N
VLVAW3N
Wall-mounted or floor-standing
Network
pollution
Power (kvar)
Low polluted
v 125
v 175
v 137.5
v 200
v 150
v 225
v 275
v 300
Tuning Factor 3.8
Tuning Factor 4.2
v 50
v 50
v 50
v 75
v 75
v 75
v 87.5
v 87.5
v 87.5
v 100
v 100
v 100
v 125
v 125
v 125
v 137.5
v 137.5
v 137.5
v 150
v 150
v 150
v 175
v 175
v 175
v 200
v 200
v 200
Power (kvar)
v 238
v 250
VLVAF4P
Floor-standing
Tuning Factor 2.7
Polluted
Available options
b IP protection for the enclosure
v IP31
v IP54, harsh and dusty environments
b Protection against direct contact with door open
v IPxxB protection
v No IPxxB protection
b Incomer protection
v 35 kA circuit breaker protection, with rotary handle
v 35 kA circuit breaker protection, without rotary handle
v 65 kA circuit breaker protection, with rotary handle
v 65 kA circuit breaker protection, without rotary handle
v No incomer protection
b Cable connection
v Top connection
v Bottom connection
b Auxiliary transformer
b Varlogic power factor controller
v NR6/12 controllers
v NRC12 controller with Modbus communication
24
VarSet offer
Ordering form
Large sites
400 V/50 Hz
Automatic compensation
Customer name: ..............................................................................................................................................................................................................................
Delivery address: ..............................................................................................................................................................................................................................
Requested delivery date: ...........................................................................................................................................................................................
Customer order no.: ...............................................................................................................................................................................................................
F Auxiliary transformer always integrated as a standard
Network
pollution
VLVAF5N
Floor-standing
Network
pollution
Power (kvar)
v 350
v 225
v 425
v 450
v 500
v 550
v 600
Tuning
Factor 3.8
Tuning
Factor 4.2
v 225
v 225
Power (kvar)
v 400
Low polluted
VLVAF6P
Floor-standing
Tuning
Factor 2.7
Polluted
v 250
v 250
v 250
v 275
v 275
v 275
v 300
v 300
v 300
v 350
v 350
v 350
v 400
v 400
v 400
v 450
v 450
v 450
v 500
v 500
v 500
v 550
v 550
v 550
v 600
v 600
v 600
Available options
b IP protection for the enclosure
v IP31
v IP54, harsh and dusty environments
b Protection against direct contact with door open
v IPxxB protection
v No IPxxB protection
b Incomer protection
v 35 kA circuit breaker protection, with rotary handle
v 35 kA circuit breaker protection, without rotary handle
v 65 kA circuit breaker protection, with rotary handle
v 65 kA circuit breaker protection, without rotary handle
v No incomer protection
b Cable connection
v Top connection
v Bottom connection
b Varlogic power factor controller
v NR6/12 controllers
v NRC12 controller with Modbus communication
25
Ordering form
VarSet offer
Large sites
400 V/50 Hz
Fixed compensation
Customer name: ..............................................................................................................................................................................................................................
Delivery address: ..............................................................................................................................................................................................................................
Requested delivery date: ...........................................................................................................................................................................................
Customer order no.: ...............................................................................................................................................................................................................
Network VLVFW0N VLVFW1N VLVFW2N
pollution Wall-mounted or floor-standing
Network
pollution
Power (kvar)
Low
polluted
v9
v 50
v 125
v 16
v 75
v 150
v 22
v 100
v 175
v 32
v 200
VLVAF4P
Floor-standing
Tuning Factor 2.7
Tuning Factor 3.8
Tuning Factor 4.2
v 50
v 50
v 50
v 75
v 75
v 75
v 100
v 100
v 100
v 150
v 150
v 150
v 200
v 200
v 200
Power (kvar)
Polluted
Available options
b IP protection for the enclosure
v IP31
b Protection against direct contact with door open
v IPxxB protection
v No IPxxB protection
b Incomer protection
v 35 kA circuit breaker protection, with rotary handle
v 35 kA circuit breaker protection, without rotary handle
v 65 kA circuit breaker protection, with rotary handle
v 65 kA circuit breaker protection, without rotary handle
v No incomer protection
b Cable connection
v Top connection
v Bottom connection
b Auxiliary transformer
26
35, rue Joseph Monier
CS 30323
92506 Rueil Malmaison Cedex
France
RCS Nanterre 954 503 439
Capital social 896 313 776 €
www.schneider-electric.com
PFCED310004EN
As standards, specifications and designs change from
time to time, please ask for confirmation of the
information given in this publication.
10-31-1247
Publication: Schneider Electric Industries SAS
Photos: Schneider Electric
Printed:
This document has been
printed on ecological paper.
01-2013
ART.056868 © 2013 - Schneider Electric - All rights reserved
Schneider Electric Industries SAS