Robustel GoRugged M1000 MP Quick Guide Chapter 1. Product Concept

Robustel GoRugged M1000 MP Quick Guide
Robustel GoRugged M1000 MP Quick Guide
Chapter 1. Product Concept
1.1 Overview
1.2 LED Indicator
After inserting the SIM card into the modem and power on, the LED indicator’s status should be as follow when work
normally:
Name Status
RUN
On
1.3 PIN assignment for modem’s DB9 female connector
RT_QG_M1000 MP_v.1.0.0
PIN
RS232
RS485 (2-wire)
Direction
1
DCD
Data+ (A)
M1000 MP  Device
2
RXD
M1000 MP  Device
3
TXD
Device  M1000 MP
4
DTR
Device  M1000 MP
5
GND
-
6
DSR
7
RTS
Device  M1000 MP
8
CTS
M1000 MP  Device
9
RI
M1000 MP  Device
24.01.2014
Data- (B)
M1000 MP  Device
1/5
Robustel GoRugged M1000 MP Quick Guide
1.4 USB Interface
USB interface can be used for sending/receiving data and power supply. When USB interface of M1000 MP is used
for sending/receiving data as well as power supply, current/voltage output of USB interface which connects to
M1000 MP’s USB interface shall at least reach to 1A/5V.
Note: Normally, current/voltage output of PC’s USB 2.0 interface is only 0.5A/5V. So when you use USB interface for
sending/receiving data, you should use power input interface for power supply (please check section 2.8 Power
Supply).
1.5 Power Supply
Note: Please take care about the polarity, and do not make reverse connection.
Chapter 2. Hardware Installation
2.1 Insert/Remove SIM Card
SIM card is used for connecting to cellular network, you need buy SIM card from local operators.
Note:
1. Don’t touch the metal surface of the SIM card in case information in the card is lost or destroyed.
2. Don’t bend or scratch your SIM card. Keep the card away from electricity and magnetism.
3. A SIM card set with PIN code cannot be used normally in the gateway without the correct PIN code.
4. Make sure to disconnect the power source from your modem before inserting and removing your SIM card.
RT_QG_M1000 MP_v.1.0.0
24.01.2014
2/5
Robustel GoRugged M1000 MP Quick Guide

2.2 Connect the External Antenna (SMA Type)
Connect this to an external antenna with SMA male connector. Make sure the antenna is for the correct frequency as
your mobile operator with impedance of 50ohm, and also connector is secured tightly.
2.3 Connect the Modem to External Device
User can use the serial cable to connect the modem’s DB9 female connector to external controller / computer.
User can use the USB cable to connect the modem’s Mini USB Connector to external controller / computer.
2.4 Power On and Connect with PC
RT_QG_M1000 MP_v.1.0.0
24.01.2014
3/5
Robustel GoRugged M1000 MP Quick Guide
Chapter 3. Operate the Modem
We can operate and configure M1000 MP via AT commands through mini USB port or serial port. This chapter will
introduce mainly AT commands examples while configuring M1000 MP.
3.1 AT Command Set
M1000 MP supports the guidelines known as the “AT Command Set.” AT Command Set is the industry standard
line-oriented command language used to communicate with the modem.
Note: You can enter AT commands to configure M1000 MP from serial software such as secureCRT which you can
download via: https://app.box.com/s/arkn6xk1asgs1myvuuie .
3.1.1 Start SecureCRT
1.
2.
Double click to start SecureCRT Potable.exe .
File->Connect->New Session
RT_QG_M1000 MP_v.1.0.0
24.01.2014
4/5
Robustel GoRugged M1000 MP Quick Guide
3.
Select Protocol as “Serial”.
4.
Select relevant COM port and match the parameters as below, click the “Next” button to finish this session.
Note:you need to match the serial parameters as: 115200,8,n,1, and disable “RTS/CTS”.
Note: Please refer to Robustel GoRugged M1000 MP User Guide to get more details about M1000’ configuration.
RT_QG_M1000 MP_v.1.0.0
24.01.2014
5/5