QSO-S PAR Sensor
The model QSO-S PAR Photon Flux sensor measures the
Photosynthetic Photon Flux (PPF) in µmol m-² s-¹ from a
field of view of 180 degrees. The diffusion disk is composed
of characterized pigments for good spectral response.
soft cloth at frequent intervals. Small changes in the level of
the sensor can also cause errors. Make sure that the top of
the domed sensor body is kept horizontal. Use the included
leveling plate to ensure the sensor level.
The sensor is designed for continuous outdoor use, and is
completely water proof and submersible. The QSO-S is
supported by the LSM1 Light Sensor Meter for PAR Sensors
or Decagon’s data loggers Em50 or Em50G.
Installation:
The sensor should be mounted with the cable pointing
toward the nearest magnetic pole. For example: in the
Northern Hemisphere, point the cable toward the North
Pole. In the Southern Hemisphere, point the cable toward
the South Pole.
Common Errors:
The biggest error is often caused by dirt on the lens of the
sensor. The domed top is self-cleaning, but measurement
accuracy will be improved if the lens is wiped with a clean,
Enabling better global research outcomes in soil, plant & environmental monitoring.
www.ictinternational.com : sales@ictinternational.com.au : +612 6772 6770
QSO-S PAR Sensor
Specifications
QSO-S PAR Photon Flux Sensor
spectral range
400 – 700 nm
Accuracy
± 5%
Resolution
2 µmol m-2 s-1
Field of View
Hemispherical, 180°
Measurement Range
Linear Range: 0-1000 mV (0-5000 µmol m-2s-1)
Full Sunlight: 400 mV (2000 µmol m-2s-1)
Calibrations and Conversions
Sensors are calibrated for outside use. 5.0 µmol m-2 s-1 per
mV
Operating Temperature
-40 to +60°C
Power
None, self powered
Cable Length
5m
Cable connector Types
3.5 mm “stereo” plug
Sensor Dimensions
2.4 cm x 2.75 cm (0.95 in x 1.1 in)
Data Logger Compatibility (not exclusive)
Decagon Em50 series, ProCheck, Campbell Scientific
Warranty
One year, parts and labor
Enabling better global research outcomes in soil, plant & environmental monitoring.
www.ictinternational.com : sales@ictinternational.com.au : +612 6772 6770
QSO-S PAR Sensor
Accessories
AWS Automatic Weather Station
Automatic Weather Station Package. Includes:
DataTrac 3 Software
DataTrac 3 Software for organising and analysing data
DWS Decagon Weather Station
DWS Decagon Weather Station
EM50 Data Logger
EM50G Data Logger
Enabling better global research outcomes in soil, plant & environmental monitoring.
www.ictinternational.com : sales@ictinternational.com.au : +612 6772 6770
QSO-S PAR Sensor
Accessories
LSM Light Sensor Meter for PAR Sensors
Light Sensor Meter - Configured for PAR sensors. 10 sensor capacity; IP65 rated
enclosure; stand-alone logging capability to 4GB MicroSD Card; Windows
software; breakout board; user manual.
ProCheck Handheld Reader
Enabling better global research outcomes in soil, plant & environmental monitoring.
www.ictinternational.com : sales@ictinternational.com.au : +612 6772 6770